National Agri Food Biotechnology Institute Tender
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
National Agri Food Biotechnology Institute - NABI Tender
Eprocure
Opening Date22 Jul 2020
Closing Date5 Aug 2020
Tender AmountRefer Documents
Costs
EMD
₹ 65,708Document Cost
₹ 590Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2020_NABI_572735_1Bid Award Id
ViewTender No
NABI/7(224)/2020-WORKSTender Authority
National Agri Food Biotechnology Institute ViewPurchaser Address
-Website
http://https://nabi.res.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply & Filling of Refrigerant R410A in Outdoor VRV units of rating 14.83Tr (18HP)
2
-
-
... More
Supply and Installation of Expansion kit for 20 HP coil
2
-
-
... More
Supply & Fixing of MS Heavy duty VRV Outdoor Units stands
2
-
-
... More
Supplying, installing, testing and commissioning of DDC Controller with I/O module, expandable to meet the IO summary listed, The controllers shall be minimum 32 bit Double microprocessor based standalone working on TCP/IP on Bacnet IP with integral web browser, calender function complete with day, month, week, year etc, real time clock & 1 second scan time. DDC working on 230V AC are preferred. The DDC's shall be capable of peer to peer communication without help of communication controller / router / system interface controller / PC and shall communicate with the building LAN directly. These shall come with lockable mounting cabinets duly powder coated connector strip, internal wiring and space to house controller & relays, connector strip step down transformer, MCB, internal wiring. (Contractor shall confirm his I/O provision w.r.t requirement on basis of data point) on AHRAE approved Bacnet protocol only. DDCs shall work on either 230V power supply or shall contain UL listed SMPS in the panel. Controller shall have 1 RS-485 Port for the Integration of VFD, Controller shall support 96 Points.DDC Controller with 15% Spare as per I/O summary attached. The BMS system shall give an alarm with hooter in case of failure of HVAC system.
1
-
-
... More
Supply, Installation Testing and commissioning of Differential Pressure Switch Across Blower (40-400 Pa). Sensor shall have Max. Operating Pressure 5000 Pa & Membrane Material: Silicone
4
-
-
... More
Supply Installation testing and commissioning of Water Flow Switch having Operating Pressure: 10Kgf/Cm2 & Withstand Pressure: 17.5Kgf/Cm2
2
-
-
... More
Supply Installation testing and commissioning of Differential Pressure Switch Across Filter (20-200 Pa). Sensor shall have Max. Operating Pressure 5000 Pa & Membrane Material: Silicone with suitable IP65 covering to suit outdoor installation
2
-
-
... More
Supply Installation testing and commissioning of Duct Temp. & RH Sensor with +/- 2% Accuracy.
1
-
-
... More
Supply Installation testing and commissioning of Wall Mount Room Temp. / RH / Delta P with 7- Segment Display with Analog Output: Temp. Sensor: 10KΩ NTC Thermistor Sensor; Temp. range: 0-50°C, Accuracy: ±0.2°C; Output: 4-20 mA/ 0-10 VDC Humidity Sensor: Thermoset polymer based capacitve sensor; Range: 0-100% RH; Accuracy: ±2% RH; Output: 4-20 mA/ 0-10 VDC Differential Pressure: MEMS piezo resistive differential sensor; range: ±250 Pa; Accuracy: ±0.5% FS; Output: 4-20 mA/ 0-10 VDC.
1
-
-
... More
Supply Installation testing and commissioning of Air Velocity Sensor
2
-
-
... More
Modification and Integration of existing Honeywell DDC Controller & Software.
1
-
-
... More
Supply, Installation, Testing and Commissioning of variable frequency drives for Air Handling Units. Variable frequency drives shall be provided with necessary sensors and transmitters complete with control wiring in all respect as required and as per specifications. VFDs shall have built-in harmonic filters. The drives shall be suitable for the following motor ratings. VFDs shall be housed in precoated, vandal proof enclosure with On/Off Push Buttons, Phase indication lights, A/M Switch and with adequate provisions for ventilation using a fan. The VFDs shall be able to receive the signals from multiple/combination of duct static pressure sensors/Temp. sensors and to ramp the speed of the motor.VFDs shall be suitable to take feed back and connectivity from all the DPS as mentioned below against each motor rating to facilitate averaging activity by VFD. Quoted price shall be inclusive of return air temperature sensor/Pressure Sensors and necessary electrical switches including change over switch & copper cabling for integration with the AHU panel. VFDs shall be installed within Electrical panels as described under Section 'Electrical Works'. Overall protection of VFDs with Panels shall be IP-54. (rating: 7.5HP)
4
-
-
... More
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water and hot water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3, grade 1 roofing feltstrip(as per IS:1322 as amended up to date) at joints repairing of damage to building etc. as per specifications and as required complete in all respect.Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above(80 mm dia MS pipes with 50 mm thick insulation).
18
-
-
... More
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water and hot water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3, grade 1 roofing feltstrip(as per IS:1322 as amended up to date) at joints repairing of damage to building etc. as per specifications and as required complete in all respect.Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above(40 mm dia MS pipes with 50 mm thick insulation).
18
-
-
... More
Supplying, fixing, testing and commissioning of following valves, in the chilled water/hot water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/ hot water circulation as specified (80 mm dia Valves)
2
-
-
... More
Supplying, fixing, testing and commissioning of following valves, in the chilled water/hot water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/ hot water circulation as specified (40 mm dia Valves)
4
-
-
... More
Supplying, fixing, testing and commissioning of following valves, in the chilled water/hot water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified.(80 mm dia Valves)
1
-
-
... More
Supplying, fixing, testing and commissioning of following valves, in the chilled water/hot water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified.(40 mm dia Valves)
2
-
-
... More
Supplying, fixing, testing and commissioning of following strainers in the chilled water/hot water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified.(80 mm dia)
1
-
-
... More
Supplying, fixing, testing and commissioning of following strainers in the chilled water/hot water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified.(40mm dia)
2
-
-
... More
Supplying, installation, testing and commissioning of Auto air vent as per the technical specs and as per the site requirement
3
-
-
... More
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required
6
-
-
... More
Providing & fixing in position the mercury in glass industrial type thermometres.
6
-
-
... More
Supply Installation Testing and commissioning of Magnehelic gauge -30 to +30 pascal range with SS Box knobs and tube etc complete as per the directions of Engineer In charge
6
-
-
... More
Providing and fixing in position the following GI B class pipes cut to required lengths and installed with all screwed joints with the necessary elbows, tees and reducers etc duly insulated as per specifications.50 mm dia pipes
15
-
-
... More
Supply, installation, testing and commissioning of 2-way motorized valves suitable for Chilled water as well as hot water application complete with Electrical / Electronic actuator, necessary wiring and required accessories for proper operation and control of valves of following sizes. (Vendor to submit the Selection sheets of the Control Valves for all sizes individually)(65 mm dia valve)
1
-
-
... More
Supply, installation, testing and commissioning of 3-way motorized valves suitable for Chilled water as well as hot water application complete with Electrical / Electronic actuator, necessary wiring and required accessories for proper operation and control of valves of following sizes. (Vendor to submit the Selection sheets of the Control Valves for all sizes individually)(32 mm dia valve)
2
-
-
... More
Supply, Installation, Interconnecting, Testing & Commissioning including vaccumization and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping between AHU & outdoor VRV units complete with fittings, with all piping properly supported, jointing/brazing including accessories, insulated with Class-0 closed cell elastomeric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines,all accessories as per specifications etc. complete as per the site requirement.(28.58 mm dia (OD)(Hard drawn) with tube thickness minimum 1.2mm with 19 mm thick insulation)
30
-
-
... More
Supply, Installation, Interconnecting, Testing & Commissioning including vaccumization and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping between AHU & outdoor VRV units complete with fittings, with all piping properly supported, jointing/brazing including accessories, insulated with Class-0 closed cell elastomeric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines,all accessories as per specifications etc. complete as per the site requirement.(15.86 mm dia (OD)(Soft drawn) with tube thickness minimum 1.2mm with 19 mm thick insulation)
30
-
-
... More
Supply, installation, balancing and commissioning of factory fabricated GSS sheel metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Duct Size 0- 750 mm (24 Gauge TDF joints) with Silicon sealant, Thickness 0.63 mm sheet
90
-
-
... More
Supply, installation, balancing and commissioning of factory fabricated GSS sheel metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Duct size 751 - 1500 mm (22 Gauge TDF joints) with Silicon sealant, Thickness 0.80 mm sheet
70
-
-
... More
Supply, installation, balancing and commissioning of fabricated at site GSS sheel metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Duct Size 0-750 mm (24 Gauge )/ MS Flange Silicon sealant, Thickness 0.63 mm sheet
10
-
-
... More
Supply, installation, balancing and commissioning of fabricated at site GSS sheel metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Duct size 751-1500 mm (22 Gauge MS Flange Silicon sealant), Thickness 0.80 mm sheet
10
-
-
... More
Supply, Installation, Testing of 125 mm deep antivibration flexible joints at the outlet of air handling units / fans. Flexible connections shall be constructed using imported fire retardant fabric with extruded aluminium frame / flange on both sides of approved make.
2
-
-
... More
Supply, installation, testing and balancing of powder coated extruded aluminium square shape ceiling diffusers with removable core and anti smudge ring as per specifications
2
-
-
... More
Supplying & fixing of opposed blade aluminium construction volume control dampers in supply air duct collars as per approved drawings and specifications.
2
-
-
... More
Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc as per specifications.
2
-
-
... More
Supplying , fixing, testing and commissioning of fire damper in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. the spring return action shall be inbuilt mechanism and are not externally mounted. The damper shall also be closed in the event of fire signal complete as required ans as per specifications.Note: Fire dampers shall be supplied with sensors/actuators/control etc duly factory fitted and tested at manufacturers works and certificate to this effect produced along with delivery of fire damper
2
-
-
... More
Supplying , fixing, testing and commissioning of Actuators of fire damper in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. the spring return action shall be inbuilt mechanism and are not externally mounted. The damper shall also be closed in the event of fire signal complete as required ans as per specifications
2
-
-
... More
Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class “O”) insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required: 19 mm thick insulation for Supply Air ducts with GC Cloth
100
-
-
... More
Designing, fabricating, transporting to site, installing, testing and commissioning of double door outdoor type, weather proof, floor mounted(with MS stand if required), self supported, compartmentalized LT cubical pattern (Extendable Type) metal clad switch board, fabricated from 2mm (14 G) thick CRCA sheet steel suitable for 31 MVA rupturing capacity at 415 V, 3 phase, 4 wire, 50 HZ AC supply and equipped with PVC sleeved aluminium bus bars of specified rating and following switch gears inter connected by PVC sleeved solid conductors, including 7-tank cleaning, degreasing, phosphating process and treatment of panel with anti-corrosive zinc based primer paint and finally powder coating the panel, complete with earthing terminals, cable and bus bar alleys and hoisting hooks as required. The LT panel will comprise ACBs and MCCBs as described below for incoming and outgoing power supplies.INCOMER: 200 Amps TPN MCCB 35 KA Microprocessor Release with 200/5A ratio Current Transformer,Multifunction Meter indicating, Voltage, Current, kWh, kVA, PF etc. with suitable CTs along-with other accessories as specified. : 1 Set, BUS BAR: 250 Amps TPN electrolytic aluminium E 91 grade bus bars with heat shrinkable insulation cover sleeves., OUTGOINGS:40 A TPN MCB with 0-40 A ammeter 40/5A Current Transformer & selector switch, 7.5 HP DOL starter with VFD bypass, SPP and aluminium conductor outgoing feeder of matching size to AHU motor and Exhaust Fan Motor : 4 Sets, 63 Amps TPN MCB with 300 mA ELCB, SPP etc complete as per requirement for ODU for 18 HP VRV units: 2 Sets, 16Amp DP MCBs for DDC controller and controls as per the site requirement: 3sets, 40A TPN MCB with Digital VIF meter for UPS: 1set,40A TPN MCB for Power & Lighting DBs: 2set, 32A DP MCBs as spare: 2set
1
-
-
... More
Supplying and laying of following 1100 volt grade XLPE insulated and PVC sheathed aluminium conductor armoured Aluminium cables on cable trays, in ducts/shafts, on walls clamped to wall with suitable clamps, saddles, and fixing bolts, or laying in ground including cost of digging, backfilling with brick and sand protection etc.complete as per the site requirement(4C x 10 sq.mm for AHU/ EU Motor)
150
-
-
... More
Supplying and laying of following 1100 volt grade XLPE insulated and PVC sheathed aluminium conductor armoured Aluminium cables on cable trays, in ducts/shafts, on walls clamped to wall with suitable clamps, saddles, and fixing bolts, or laying in ground including cost of digging, backfilling with brick and sand protection etc.complete as per the site requirement(4C x 16 sq. mm for VRV ODUs)
80
-
-
... More
Supply & laying of 1.1kV grade Copper conductor, PVC insulated ISI marked heavy duty armoured Cable (IS:1554-1976) (Part-I) with end termintaion including thimbling, glands etc. complete as per the site requirement(3.0 C x 2.5 sq.mm)
50
-
-
... More
Supply & laying of 1.1kV grade Copper conductor, PVC insulated ISI marked heavy duty armoured Cable (IS:1554-1976) (Part-I) with end termintaion including thimbling, glands etc. complete as per the site requirement(4.0 C x 2.5 sq.mm)
50
-
-
... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, with GI cover, joined with connectors, fixed on the floor or on wall with painted MS Angular supports including G.I. bolts & nuts, fasteners etc. complete as per the site requirement.(300 mm width X 50 mm depth X 1.6 mm thickness)
40
-
-
... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, with GI cover, joined with connectors, fixed on the floor or on wall with painted MS Angular supports including G.I. bolts & nuts, fasteners etc. complete as per the site requirement.(225 mm width X 50 mm depth X 1.6 mm thickness)
30
-
-
... More
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
150
-
-
... More
Supply, Laying, Testing and Commissioning of Cat-6 in 25 mm PVC Conduit with complete Accessories.
250
-
-
... More
Supply, Laying, Testing and Commissioning of 2 C X 1.5 Sq.mm Shielded Cable in 25 mm PVC Conduit with complete Accessories.
300
-
-
... More
Supply, Laying, connecting, testing and commissioning of new control cum transmission copper flexible cable of size 2 core x 1.0 sq mm in suitable size PVC conduits between AHU & VRV outdoor units and to central remote, if applicable
30
-
-
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.(4C X 10 sq. mm)
8
-
-
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.(4C X 16 sq. mm)
4
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements