National Agri Food Biotechnology Institute Tender
... More
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
National Agri Food Biotechnology Institute - NABI Tender
Eprocure
Opening Date19 Mar 2024
Closing Date8 Apr 2024
Tender Amount₹ 1,51,39,110
Costs
EMD
₹ 3,02,783Document Cost
₹ 590Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_NABI_801558_1Bid Award Id
ViewTender No
NABI/ENGG/7(006)/2022-23-WORKSTender Authority
National Agri Food Biotechnology Institute ViewPurchaser Address
-Website
http://https://nabi.res.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
NIT for the Annual Operation and Maintenance contract of Electrical, Civil works, Firefighting, Public Health and Allied Services
BoQ for the Annual Operation and Maintenance contract of Electrical, Civil works, Firefighting, Public Health and Allied Services
BOQ Items
... More
Filling the gap in between aluminium frame/adjacent RCC/ Brick/Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete :- As per site conditions
300
-
-
... More
Painting with synthetic enamel paint of approved brand and
manufacture of required colour to give an even shade: One or more coats on old work
200
-
-
... More
Services for cleaning of underground, overhead tanks in various buildings of campus . The cost includes washing, mechanical de-watering, sludge removal with pumps, high pressure washing, brushing, surface cleaning, vaccum cleaning and disinfection including spraying and UV air germicidal radiator, scaffolding, profit etc all inclusive for one year (4 times in a year ).
1
-
-
... More
Cleaning of storm, sewer catch basin, pipe lines, manholes manually/mechanically for one year (1 times in a year all sewer line/manholes/storm lines to be clean by suction machine/manually). with deployment of workers/suction tanks & day to day basis as per requirement blockage in sewer lines/toilet lines to be unblocked by Suction pump/sewer man to be done by contractor only. No amount will be payble except the quoted amount
1
-
-
... More
Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin-charge .The elevational area of the scaffolding shall be measured for payment purpose
300
-
-
... More
Earth work in surface excavation as per site conditions including getting
out and disposal of excavated earth upto 500 m as directed by Engineer-in- Charges: All kinds of soil
100
-
-
... More
Filling available excavated earth (excluding rock) in trenches, plinth,
sides of foundations etc. in layers not exceeding 20cm in depth,
consolidating each deposited layer by ramming and watering, lead up
to 500 m and lift upto 1.5 m.
50
-
-
... More
Providing and laying in position cement concrete of specified grade
including the cost of centering and shuttering - All work up to plinth
level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone
aggregate 20 mm nominal size)
3
-
-
... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class
designation 7.5 in foundation and plinth in: 1:4 of Cement & Mortar
3
-
-
... More
12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand)
100
-
-
... More
Demolishing concrete manually/ by mechanical means and
disposal of material within 500 metres lead as per direction of Engineerin-charge
20
-
-
... More
Demolishing brick work in cement mortar manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material
within 500 metres lead as per direction of Engineer-in-charge.
5
-
-
... More
Supply of JCB for cleaning/dressing/levelling and other civil works or excavation of any work
30
-
-
... More
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI 212-3R-2010 i.e by reducing permeability of concrete by more than90% compared with control concrete as per DIN 1048 and resistantto 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. For vertical and horizontal surface
300
-
-
... More
Providing and injecting approved grout in proportion recommended by the manufacturer into cracks/honey-comb area of concrete/ masonry by suitable gun/pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-in Charge Epoxy injection grout in concrete/RCC work of approved
make
25
-
-
... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. (Upto 35 sq. mm)
50
-
-
... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. (Above 35 sq. mm and upto 95 sq. mm)
50
-
-
... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. (Above 95 sq. mm and upto 185 sq. mm)
50
-
-
... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. (Above 185 sq. mm and upto 400 sq. mm)
50
-
-
... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required Upto 35 sq. mm
50
-
-
... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required Above 35 sq. mm and upto 95 sq. mm
50
-
-
... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required Above 95 sq. mm and upto 185 sq. mm
50
-
-
... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required Above 185 sq. mm and upto 400 sq. mm
50
-
-
... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required Upto 35 sq. mm (clamped with 1mm thick saddle)
50
-
-
... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as required. (Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp))
50
-
-
... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as required. (Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp))
50
-
-
... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as required. (Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp))
50
-
-
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1kV grade as required. (3 X 25 sq. mm (25 mm))
10
-
-
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1kV grade as required. (3 X 10 sq. mm (22 mm))
10
-
-
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1kV grade as required. (3 X 16 sq. mm (25 mm))
10
-
-
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1kV grade as required. (3 X 35 sq. mm (28 mm))
10
-
-
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1kV grade as required. (4 X 25 sq. mm (28mm))
10
-
-
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1kV grade as required. (4 X 10 sq. mm (25mm))
10
-
-
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1kV grade as required. (4 X 16 sq. mm (28mm))
10
-
-
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1kV grade as required. (4 X 35 sq. mm (32mm))
10
-
-
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1kV grade as required. (3½ X 50 sq. mm (35 mm))
10
-
-
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1kV grade as required. (3½ X 70 sq. mm (38mm))
10
-
-
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1kV grade as required. (3½ X 95 sq. mm (45 mm))
10
-
-
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1kV grade as required. (3½ X 120 sq. mm (45 mm))
10
-
-
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1kV grade as required. (3½ X 150 sq. mm (50 mm))
10
-
-
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1kV grade as required. (3½ X 185 sq. mm (57mm))
10
-
-
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1kV grade as required. (3½ X 240 sq. mm (62mm))
10
-
-
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1kV grade as required. (3½ X 300 sq. mm (70mm))
10
-
-
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1kV grade as required. (3½ X 400 sq. mm (82mm))
10
-
-
... More
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. (3 X 16 sq. mm (25 mm))
20
-
-
... More
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. (3 X 25 sq. mm (25 mm))
20
-
-
... More
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. (3 X 35 sq. mm (28mm))
20
-
-
... More
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. (4 X 25 sq. mm (28mm))
20
-
-
... More
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. (4 X 35 sq. mm (32mm))
20
-
-
... More
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. (3½ X 50 sq. mm (35 mm))
20
-
-
... More
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. (3½ X 70 sq. mm (38mm))
20
-
-
... More
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. (3½ X 95 sq. mm (45 mm))
20
-
-
... More
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. (3½ X 120 sq. mm (45 mm))
20
-
-
... More
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. (3½ X 150 sq. mm (50 mm))
20
-
-
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1kV grade as required. (3½ X 185 sq. mm (57mm))
20
-
-
... More
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. (3½ X 240 sq. mm (62mm))
20
-
-
... More
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 kV grade as required. (240 sq. mm)
4
-
-
... More
Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 kV grade as required. 240 sq. mm)
4
-
-
... More
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required.
10
-
-
... More
Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and or good soil after laying of cable/ pipe etc. in layers of 20 cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 meter.
100
-
-
... More
Excavation of the cable trenches in hard rock not exceeding 1.5 meter in width, and lift upto 1.5 meter, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 meter.
100
-
-
... More
Filling available excavated earth (excluding rock) in trenches, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 meter.
100
-
-
... More
Fault finding of LT Cable of 1.1kV Grade, of any size and burried in ground or layed in open cable trenches or inside buildings above false ceilings or in shafts etc. as per the site requirement with fault locator machine to be hired from outside
40
-
-
... More
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 kV grade as required. (300 sq. mm)
4
-
-
... More
Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 kV grade as required. (300sq. mm)
4
-
-
... More
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. (3½ X 300 sq. mm (62mm))
20
-
-
... More
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. (3½ X 400 sq. mm (82mm))
20
-
-
... More
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. (4 X 16sq. mm (28mm))
20
-
-
... More
Fault finding of HT Cable of 11kV Grade, of any size and burried in ground or layed in open cable trenches or inside buildings above false ceilings or in shafts etc. as per the site requirement with fault locator machine to be hired from outside
10
-
-
Evaluation Notes How It Works ?