Municipal Corporation Tender
... More
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Municipal Corporation Tender
Solid Waste Management
Eprocure
Opening Date6 May 2025
Closing Date13 May 2025
Tender Amount₹ 11,99,734
Costs
EMD
₹ 23,995Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MCC_85745_2Bid Award Id
ViewTender No
MCC/EE/SWM/2025-26/2Tender Authority
Municipal Corporation ViewPurchaser Address
-Website
http://etenders.chd.nic.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
DNIT for Repair and Mtc. of HT Sub Station at Solid Waste Processing Plant Sector 25W Chandigarh.
BOQ Items
... More
Service of RMU (ring main unit) all incoming and outgoing supply with (oil gressing, Meter panel,Relay setting, terminator/ dismantling/re-erection of cable proper way to do job. 1. All there defective RMU to be repaired and proper servicing before re-installation. 2. All control circuits to be checked and repaired/replaced if required. 3. All relays/indicator to be made working condition. 4. All incoming and outgoing main HT and LT cable to be properly thimbled and connected 5. Main Bus bar to be checked for healthiness
1
82600
82600
... More
Supply erection testing and commissioining of Dry type battery to backup of HT unit for breakdown supply backup. The work should be executed as per the entire satisfaction of Engineer in Charge
55
5900
324500
... More
Charger of Battery bank with stand for HT panel (RMU Unit). The work should be executed as per the entire satisfaction of Engineer in Charge
1
177000
177000
... More
S&E of Mouled Case Circuit Breakers (MCCB) of rating 400Amp with Breaking Cap 36 kA, 415 Volts.
Supply & Erection of 4 pole, 36 kA, 400 Amp MCCB with adjustable thermal and magnetic setting having Ics 75% of Icu. The MCCB is to be fixed in the feeder pillar complete in all respects. The MCCB should be make Havells/ ABB/ L&T/ Legrand/ Schneider. The work shall be executed to the entire satisfaction of Engineer-in-Charge.
1
25182
25182
... More
S&E of Mouled Case Circuit Breakers (MCCB) of rating 250Amp with Breaking Cap 36 kA, 415 Volts.
Supply & Erection of 4 pole, 36 kA, 250 Amp MCCB with adjustable thermal and magnetic setting having Ics 75% of Icu. The MCCB is to be fixed in the feeder pillar complete in all respects. The MCCB should be make Havells/ ABB/ L&T/ Legrand/ Schneider. The work shall be executed to the entire satisfaction of Engineer-in-Charge.
2
23214
46428
... More
Earthing with G.l. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry 'enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. The work should be executed as per the entire satisfaction of Engineer in Charge
12
6883
82596
... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. The work should executed as per the entire satisfaction of Engineer in charg
50
206
10300
... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
2
12259
24518
... More
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc.as required... The work should executed as per the entire satisfaction of Engineer in charge
20
1123
22460
... More
Supply erection testing and commissioning of Capactor 25 KVAR to replace the defective burnt capactor. (1KVR= 350 i.e 25KVR X 350=8750 as per quotation attached ) The work should be executed as per the entire satisfaction of Engineer in Charge
10
10325
103250
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements