Military Engineer Services Tender
... More
The MES has issued a formal invitation for competitive bids for the Military Engineer Services project, for Repair/maint Of Ht Switch Gear, Ht Safety Devices And Other Connected Items At Nams in Amritsar, Punjab, with an estimated contract value of Rs. 42,00,000. The bid opening date for this tender is 09-06-2025 and the last date for bid submission is 30-06-2025. Interested bidders for Military Engineer Services tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.
Costs
EMD
₹ 84,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_713215_1Tender No
83026/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Material and labour for repair/replacement of DC electric wiring as per site reuirment complete suitable for 11KV VCB 630 Amp and with male and female scoket 52 Pin type as per existing complete all as specified and directed.
3
-
-
... More
Material and labour for repair/replacement of AC electric wiring as per site requirment complete suitable for 11 KV VCB 630 Amp complete all as specified and directed.
3
-
-
... More
Material and labour for replacent of vacuum interrupter bottle suitable of 11 KV VCB 630/800 Amp complete all as specified and directed.
2
-
-
... More
Material and labour for in replacement of multifunction relay IDMT suitable for 11 KV ,630/800 Amp VCB complete all as specified and directed.
2
-
-
... More
Supply and fix in replacement multifunction meter suitable for 11 KV ,630/800 Amp VCB complete all as specified and directed.
2
-
-
... More
Supply and fix in replacement master trip relay suitable for 11 KV ,630/800 Amp VCB complete all as specified and directed.
2
-
-
... More
Supply and fix in replacement spring charging electric motor universal 24 V -110V , speed < 2000 RPM suitable for VCB of cap 630/800 Amp with complete accessories as per existing complete all as specified and directed.
2
-
-
... More
Material and labour for locating the fault in Transformer of any capacity , pole mounted/ plinth mounted, laid indoor on ground , repair/ replacement of defected gasket, HT bush , LT bush, replacement of thimble of transformer 100 KVA to 500 KVA , maggering transformer for detecting fault and retapping complete and make the transformer serviceable complete all as specified and directed.
Note :- (i) All tools and plant including magger , ladder and othe equipment will be arranged by the contractor with no extra cost paid to contractor.
(ii) One transformer will be catered as one Job
(iii) Contractor shall deposit / Procure all the material in advance to avoid any late night fault/ after market hours / non availability of material in market. The elect supply shall be restore within 8-12 hours from the time of tripping / fault in day or night in the stn, failing this a panelty of Rs 1000/- per complaint / fault will be imposed on the contractor from contractor dues.
(iv) Minimun one transformer shall be produce to contractor for restand/ repair for one visit. Contractor will not demand all job in one visit. Visit and Repair charges of electrician and helper are included in the quoted rate. no extra charges paid to contractor.
(v) Strip opening of transformer for detecting fault shall be included in the quoted rate. No extra amount shall be paid to the contractor.
Note :- (i) Gasket, Copper / Aluminum thimble, HT/ LT Tape for any size of transformer will be included in the quoted rate . No extra amount shall be paid to the contractor for the same.
(ii) LT/ HT rod , transformer oil and insulator shall be measured and paid seperately.
12
-
-
... More
Material and labour for top up of deficient transformer oil in transformer of any cap having dielectric strength not less than 60 KV at 4 mm gap conforming to IS complete all as specified and directed.
1000
-
-
... More
Material and labour for replacement of LT Rod brass assembly with nuts,bolts washers & bushings suitable for LT side of the transformer of any make and capacity 100-160 KVA complete all as specified and directed.
8
-
-
... More
Material and labour for replacement of LT Rod brass assembly with nuts,bolts washers & bushings suitable for LT side of the transformer of any make and capacity 200-315 KVA complete all as specified and directed.
10
-
-
... More
Material and labour for replacement of HT Bush Rod brass assembly with nuts,bolts washers complete suitable existing size of transformer of any make and capacity 100-315 KVA complete all as specified and directed.
8
-
-
... More
Supply and replacing silica gel breather clear view type including first fill of good quality silica gel of capacity0.5 kg suitable for 100 to 315 KVA transformer complete all as specified and directed.
6
-
-
... More
Supply and replacing silica gel breather clear view type including first fill of good quality silica gel of capacity 01 kg suitable for 400 to 630 KVA transformer complete all as specified and directed.
6
-
-
... More
Supply and fixing in replacement of HT underground cable XLPE insulated PVC bedded, galvanised steel strip armoured electric power cables (heavy duty) with stranded aluminium conductor 11000 volts grade cross sectional area 95 sqmm 3 core, laid in duct / trench/along pole etc including making connection complete all as specified and directed.
500
-
-
... More
Supply and fixing in replacement of HT underground cable XLPE insulated PVC bedded, galvanised steel strip armoured electric power cables (heavy duty) with stranded aluminium conductor 11000 volts grade cross sectional area 185 sqmm 3 core, laid in duct / trench/along pole etc including making connection complete all as specified and directed.
290
-
-
... More
Excavation in trenches in soft/loose soil n.exc. 1.5m wide and n. exc. 1.5m in depth and getting out for laying of cables complete all as specified and directed.
300
-
-
... More
Excavation in trenches in soft/loose soil n.exc. 1.5m wide and exc 1.5 m but not exc. 3 m in depth and getting out for laying of cables complete all as specified and directed.
1
-
-
... More
Returning, filling in, and including spreading, levelling,watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
238
-
-
... More
Removing excavated material n. exc. 50m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed.
62
-
-
... More
Material and labour for Sand cushioning to underground cable 8cm before laying the cable and 15cm (punned down to 18 cm) after laying and stretching the cable complete all as specified and directed.
52
-
-
... More
Supply and laying in replacement for un-reinforced precast concrete cable cover factory made, class HV, type I, flat of size 300mm x 180mm x 40mm complete all as specified and directed.
2800
-
-
... More
Material and labour for Boring of holes under road, pavement, hard standing by trenchless ultra sound technology/mannual all as per site requirment complete all as specified and directed.
30
-
-
... More
Supply and laying GI steel tubing, 80mm bore, light grade with all fittings, laid in trenches / under roads / along pole / wall for protection of Cable / GI wire / GI strip etc complete all as specified and directed.
24
-
-
... More
Supply and laying GI steel tubing, 100mm bore, light grade with all fittings, laid in trenches / under roads / along pole / wall for protection of Cable / GI wire / GI strip etc complete all as specified and directed.
30
-
-
... More
Material and labour for replacement of HT lightening arrestor for outdoor use, expulsion type, POLYMER complete with all fittings, transmission class, discharge capacity 65kilo amps, minimum working pressure 11000volts grade conforming to IS, complete all as specified and directed.
9
-
-
... More
Supply and fix out door type , polymer , triple pole, 11000 volts mechanically operated Air break switch (GOD + DO), mounted on 15 Nos insulators and steel frame, with operating mechanism worked from ground level for current rating up to 200 amps and all accessories ie pipe clamp etc complete all as specified and directed.
9
-
-
... More
Dismantling of existing transformer platform and Material and laying for construction of new platform for mounting of transformer using brick masonary of sub class 'B' brick (old size). Plateform size is 3000mmx2500mmx1800mm including foundation depth of 600mm below ground level and incl earth filling with hard core of 63 mm stone aggregate with PCC 1:3: 6 on top and finishing with PCC 1:2:4 with 20mm stone aggregate on top incl. two coat of cement base paint over one coat of primer on plateform walls and fixing of two Nos MS channel of size MC 80 at the centre of plateform top for moving of transformer wheels, including of 4 x danger notice board for HT 11000 volt fixed to each side of transformer fencing complete all as specified and directed.
Note: - Any excavation/ earth work and PCC work/Hard core work shall be deemed to be including in the quoted rates.
2
-
-
... More
Supply , jointing ,testing in repair end termination jointing kit heat shrinkable out door type ,suitable for HT 11000 volts grade XLPE UG cable of size 400 sqmm 3 core complete all as specified and directed.
2
-
-
... More
Supply , jointing ,testing in repair end termination jointing kit heat shrinkable out door type ,suitable for HT 11000 volts grade XLPE UG cable of size 120 to 185 sqmm 3 core complete all as specified and directed.
10
-
-
... More
Suplly and fix in in replacement End termination joint heat shrinkable outdoor type suitable for 11000 volts grade XLPE UG cable of size 95 Sq mm 3 core ,complete all as specified and directed.
10
-
-
... More
Supply , jointing ,testing in repair end termination jointing kit heat shrinkable Indoor type ,suitable for HT 11000 volts grade XLPE UG cable of size 400 sqmm 3 core complete all as specified and directed.
2
-
-
... More
Supply , jointing ,testing in repair end termination jointing kit heat shrinkable Indoor type ,suitable for HT 11000 volts grade XLPE UG cable of size 120 to 185 sqmm 3 core complete all as specified and directed.
6
-
-
... More
Suplly and fix in in replacement End termination joint heat shrinkable Indoor type suitable for 3 core 11000 volts grade XLPE UG cable of size 95 Sq mm complete all as specified and directed.
8
-
-
... More
Supply , jointing ,testing in repair for straight through jointing kit heat shrinkable ,suitable for HT 11000 volts grade XLPE UG cable of size 240 to 400 sqmm 3 core complete all as specified and directed.
3
-
-
... More
Supply , jointing ,testing in repair for straight through jointing kit heat shrinkable ,suitable for HT 11000 volts grade XLPE UG cable of size 120 to 185 sqmm 3 core complete all as specified and directed.
7
-
-
... More
Supply , jointing ,testing in repair for straight through jointing kit heat shrinkable ,suitable for HT 11000 volts grade XLPE UG cable of size 95 sqmm 3 core complete all as specified and directed.
6
-
-
... More
Material and labour for making of duct cover by using 50mmx 50mmxx6mm thick angle iron of size 145 Cm x45cmx5 cm duly welded and using MS bar for each 10 mm of frame and necessary PCC work 1:2:4 etc., complete all as specified and as directed .
120
-
-
... More
Suplly and fix in MS plates chequered Fe-410-W (Gde E-250) quality B, square cut or notched ordinary for electric cable trench covers without any attachments duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
12
-
-
... More
Dismantling of old PCC pole and supply & fixing of new Steel tubular pole complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 11 mtr long complying with requirement of IS-1678-1978 including painting of poles with two coats of synthetic aluminium paint and black & white strip of 30cm width upto 1.5 mtr high from coping over a coat of primer including numbering of poles complete all as specified and directed.
Note:- Exavation and foundation will be paid and measure separetly.
8
-
-
... More
Material and labour for PCC ( 1:2:4) type B1 using 20mm graded stone aggregate for coping pedestal of poles. Including necessary form work fair finished to exposed surface complete all as specified and directed.
1
-
-
... More
Material and labour for PCC 1:3:6 type C-1 using 20mm graded broken stone aggregate as in mass concrete in foundation of stays and poles complete all as specified and directed.
7
-
-
... More
Material and labour for PCC ( 1 : 3 : 6 ) type C2 using 40mm graded stone aggreghate for foundation of poles and stay assembly complete all as specified and as directed.
1
-
-
... More
Material and labour for replacement cross arms bracings supports clamps and back plates fabricated from structural steel sections including nut bolts washers welding bending cold and hot drilling holes for bolts in any shape or size as indicate or directed and inclusive of one primer coat one under coat and one finishing coat of paint etc. complete all as specified and directed.
10
-
-
... More
Material and labour for earthing complete with galvanized iron or steel plate electrode 600 mm x 600 mm x 6.00 mm thick buried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized wire 4 mm dia as earthing lead by means of GI bolts, nuts, check nuts and washers, earth wire protected by galvanized steel pipe 20 mm bore (light grade) connected to machinery/ equipment all as shown in electrical plate No. 3 of SSR-2010 Part I and including necessary excavation and earth work in any type of soil, 20mm bore light grade GI pipe for watering, funnel, wire mesh, PCC (1:3:6) type C-1 chamber, MS cover of thickness 5mm openable type and having suitable locking arrangement and MS frame of suitable size made of angle iron 50 x 50 x 60 mm, complete all as specified. Note: (i) The unit rate includes earth lead and protection pipe up to maximum 7.5 metre from earth plate to earth point/test point. (ii) Earth pit shall be constructed minimum 0.5 metre away from earth complete all as specified and directed.
5
-
-
... More
Supply and Fix in replacement of old unserviceable conventional/ LED flood Light with new LED Flood light 120 watt ,high power SMD LED cool white, supply voltage 220/240/50 Hz, light engine driver base.pole adapter,pressure die cast polycarbonate, powder coated in IP 66 Including protection over temperature fixed on 66 KV Sub Stn grid/ Sub Stn Bldg including fixing arrangement as per site requirement ie clamps, nut and bolts etc complete all as specified and directed.
6
-
-
... More
Material and labour in replacement for high voltage fire resistant, flame retardant self adhesive electrical insulation tape suitble for 11KV (RYB), high quality self melgamate size minimum 38mm width and 09 mtr length complete all as specified and directed.
50
-
-
... More
Material and labour for providing 40mm broken stone aggregate including spreading and levelling complete all as specified and directed.
20
-
-
... More
Supply and fix in replacement of Potentional Transformer (PT) Fuse capacity 3/3.5 Amp suitable for 11 KV VCB complete all as specified and directed.
10
-
-
... More
Supply and fix in replacement and providing of double space heater strip type 80Watt each including 1.5 Sqmm wiring and thermostate suitable for 11 KV VCB complete all as specified and directed.
12
-
-
... More
Supply and fix in replacement of 11KV support insulator suitable for 11KV VCB (VCB make Areva,Kirloskar & CG ), dismantling and mantling of VCB Panel labour charge,high quality 11KV VCB busbar Insulation Material and Nutbolts included in quoted rates complete all as specified and directed.
12
-
-
... More
Supply and fix in replacement of 11KV spoutt insulator suitable for 11KV VCB (VCB make Areva,Kirloskar & CG ), dismantling and mantling of VCB Panel labour charge,high quality 11KV VCB busbar Insulation Material and Nutbolts included in quoted rates complete all as specified and directed.
6
-
-
... More
Material and labour for replacement of old defective Potentional Transformer (PT) unit of 11000volt/110Volt suitable for 11 KV VCB as per existing size/make/fixing in existing space complete all conncetion & testing to be done by contractor without any extra cost operating of device for smooth operation incl replacement of worn out any type/size nut/bolts and washers complete all as specified and directed.
3
-
-
... More
Supply and fix in replacement of power pack 220 Volt AC to 24 Volt DC for 11 KV VCB suitable for as per existing space ,make matching with the existing breaker and testing complete all as specified and directed .
2
-
-
... More
Material and labour for CRC electra clean for dusting/rusting/ carbon cleaning on VCB Mechanism of 400 ml capacity suitable for 11 KV VCB and air break switches complete all as specified and directed.
30
-
-
... More
Material and labour for replacement of copper ribbon suitable for 200 amps rated capacity gang operative switch, 45 CM long complete all as specified and directed .
30
-
-
... More
Excavates and relaying HT cables loops near the poles ,transformers, VCB , cutting the damages/burnt parts of cable and reconnecting its into positions complete with thimbles, nut bolts, sleaves complete all as specified and directed.
20
-
-
... More
Material and labour for provision for detection of 11 KV HT cable fault through finding and fault locating high voltage mobile machine to locate the fault in 11 KV HT cable and fixed out exact location of fault complete all as specified and directed.
Note : (i) The item includes transporation, charging machine upto detecting fault at time. (ii) HT cable joint, necessary excavation & earth work complete will be measured and paid separately against respective item of the schedule.
5
-
-
... More
Labour required for trimming / cutting of tree branches / long bushes / bambooes (of any girth), touching/obstructing the over head HT lines at places so as to keep minimum 1.50 Metre clearance all around the lines and disposal thereof to not exceeding 100 Mtrs distance after taking proper electric shut down from concerned staff complete all as specified and directed. (Note : Linear length centre to centre of the pole shall only be measured)
40
-
-
... More
Material & labour for restrainging ACSR conductor HT/LT providing proper complete all as specified and directed.
Note : Upto 5 conductor will be consider as one span only.
45
-
-
... More
Dismantling of old ACSR conductor of any size and Supply and fixing new ACSR conductor on HT poles including stringing and fixing in position and binding to insulators and jumpers complete all as specified and directed
2
-
-
... More
Material and labour for cleaning of installation/ substation including clearing of vegitation, wild growth and trimming of grass, cutting of tree branches, removing of debris etc around the installation compound and removing rubbish off the premises complete all as specified and directed.
1000
-
-
... More
Material and labour for jointing broken/ laying on ground conductor and restrach the same conductor with straching of 3 to 4 span complete with maintaing proper complete all as specified and directed.
Note :- Conductor required for jointing broken conductor shall be included in the quoted rate. No extra payment shall be made to the contractor for the same.
20
-
-
... More
Material and labour for cable route indicator for HT UG cable of 11000 Volts bolted with 40x6mm flat iron member of height 0.60m and 80mm dia CI plate, embeded in PCC 1:3:6 type C-2 of size 20cm x 20cm x 30cm block complete all as specified and directed.
70
-
-
... More
Material and labour for replacement of electrical shock treatment chart in Hindi ,english and Punjabi complete with figures and letters complete of size not less than 50 cm x 75 cm Engr-in-Charge with white paint complete all as specified and directed.
20
-
-
... More
Cleaning, dehydration/ reconditioning of transformer oil different location by dehydration plant including testing as per IS Specification and result not less than 40 KV at site, complete all as specified and directed.
2400
-
-
... More
Material and labour for providing earthing of advance chemical earthing system of pure copper pipe chemrod 3 mtrs long 50mm dia filled with highly conducting metallic compounds with the permanent sealings at both the ends. Top of the earth electrode shall be compressed to form an extended lead with 2 holes for connecting the strip / wire to the load. To ensure the moisture content and clectrical conductivity each earting pit shall be provided with minimum 2 bags of 25 Kg chemical compound. An arrangement for connection of copper strip 20 x 3 mm to rod to be made with given teminal point through gas welding, including polymer chamber with cover proper cover alongwith locking arrangement and necessary excavation in any type of soil , returning filling in removal of surplus soil complete all as specified and directed.
Note :- Chemical earthing shall only be carried out in presence of company representative and a test report of earthig alongwith result sheet shall be submitted by the company through contractor.
15
-
-
... More
Suplly and fix in in replacement for copper strip of size 20x3 mm from test point to transformer or other places complete all as specified and directed.
70
-
-
... More
Material and labour for Natural river sand for cushioning to underground cable in trench/ in ducts of sub stations/ under power transformer complete all as specified and directed.
16
-
-
... More
Supply and spraying anti vegetation chemical liquid of 1ltrs bottle mixed with water complete all as specified and directed.
Note :- (i) Area for sparay is 66 KV MRS, TOP-I Sub Stn, TOP-II Sub Stn, Red Colony MAP Sub Stn, Kathania MAP Sub Stn, NME MAP Sub Stn, Khetarpal MAP Ssub Stn, NOC MAP Sub Stn, and other unmanned sub stn / around LT Panel in NAMS Area
(ii) Complete anti vegeration chemical shall be deposit in advance and will be sprayed by the Contractor labour as per direction and location where directed.
50
-
-
... More
Material and labour for painting of steel pole , 11 KV 4 pole sturecture including all channel and air break switch and clamps at power house with two coat of aluminum paint complete all as specified and directed.
Note : Cost of Aluminum and Black/white Paint to be included in quoted rate.
8
-
-
... More
Material and labour for painting of steel pole , 11 KV 2 pole sturecture including all channel and air break switch and clamps at power house with two coat of aluminum paint complete all as specified and directed.
Note : Cost of Aluminum and Black/white Paint to be included in quoted rate.
4
-
-
... More
Material and labour for painting of PCC pole , 11 KV 2 pole sturecture of all channel and air break switch and clamps at 11 KV power house with two coat of aluminum paint and Black and white patti from up 1.2 mtr length of PCC pole from GL complete all as specified and directed.
Note : Cost of Aluminum and Black/white Paint to be included in quoted rate.
14
-
-
... More
Material and labour for painting of PCC pole , 11 KV 4 pole sturecture of all channel and air break switch and clamps at 11 KV power house with two coat of aluminum paint and Black and white patti from up 1.2 mtr length of PCC pole from GL complete all as specified and directed.
Note : Cost of Aluminum and Black/white Paint to be included in quoted rate.
18
-
-
... More
Material and labour for replacement of HT Copper bus bar 1200 Amp, suitable for HT VCB used for common Bus bar in VCB Panel including cutting as per site and making holes for cable connectiona complete with HT insulation as per colour coding RYB and as required at site complete all as specified and directed.
10
-
-
... More
Suplly and fix in in replacement of Synthetic rubber insulated mats 3.0 mm thick for voltage up to 33KV for electrical purpose as per IS 15652-2006, (superseding IS-5424) suitable for electrical shock safety of sizes 2mx1m , complete all as specified and directed.
14
-
-
... More
Supply and fixing pin type porcelain type insulators including galvanised mild steel spindle, two galvanised iron washers, and one galvanised iron nuts, 150mm height 150 mm dia including section of straps of 38x5mm size 20mm dia of bolts, nuts & washers for 11000 volts grade, completed all as specified and directed.
20
-
-
... More
Supply and fix in replacement of disc type insulator, porcelain, vitreous white, brown or green insulators for working pressure 11000 Volts of 145 mm height 255mm dia ball and socket type 'Single Disc' assembly for tension with tension clamp for conductors including bolts, nuts & washers complete all as specified and directed.
6
-
-
... More
Supply and fixing in replacement of stay assembly comprising of 7/2.50mm galvanized MS stay wire of reqd length, fixed to poles with and including of FI clamps made out of FI 40x6mm and nuts bolts washers of suitable size MS stay bow 14mm dia galvanized 40cm long MS galvanised stay rod threaded with nut 16mm dia 21 Cm long with washers MS stay plate galvanized 230x30x6mm and stay wire complete all as specified and as directed. Note necessary Excavation and PCC shall be measured and paid seprrately
8
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%