Military Engineer Services Tender

... More
The MES has issued a formal invitation for competitive bids for the Military Engineer Services project, for Repair/ Maintenance And Improvement Of Central Type Ac Plant And Connected Works At Af Stn Adampur in Jalandhar, Punjab, with an estimated contract value of Rs. 44,99,000. The bid opening date for this tender is 23-05-2025 and the last date for bid submission is 12-06-2025. Interested bidders for Military Engineer Services tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date23 May 2025
Closing Soon12 Jun 2025
Tender Amount₹ 44,99,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for servicing of Air Handling units by removing the filter, vaccumising the filter, washing the filter and reinstalling the cleaned filter, brush the cooling coil and spray the foam coil cleaner including rinsing of coil, alignment of shaft & motor, servicing of chilled water line strainer for the AHUs, tightening of terminals of motor, replacement of V belts, replacement of bearings complete all as specified :- Note :- (i) The rate quoted deemed to be inclusive of blowing out the dust, chemical cleaning by spraying the organic based scale removing agent (Vaniklin) at the appropriate ratio till removal of complete dust & scale deposits in the fin area of evaporator coil, flushing through for proper air flow across he coil, cleaning of air filters, greasing of blower motor, replacement of unserviceable bearings, V belts, water drain lines, renewal of rusted sheet metal screws, applying synthetic enamel paint over a coat of primer on the rusted portion and testing & commissioning the unit.

-

-

-

... More
4000/5000 CFM

3

-

-

... More
8000/10000 CFM

3

-

-

... More
15000/20000 CFM

3

-

-

... More
M&L for carrying out servicing/ overhauling, repairs and maintenance of Cooling tower of upto 100 TR water cooled chiller type central AC plant by dismantling/ taking down the CT fan motor of flange mounted extended type shaft upto 7.5 HP, 3 Phase, 415 volts, 50 Hz, along with fan assembly and including cleaning & removal of scales, inspection, cleaning and replacement of PVC fills, PVC eliminator, FRP louvers, motor cover, splash cups etc complete including renewal of all corroded bolts & nuts, terminal block and re assembling, fixing in position, fixing of fan blade and alignment of the fan blade for the suitable air throw of the cooling tower, painting with two coats of synthetic enamel paint over a coat of anticorrosive paint after preparation of surface, testing and commissioning the cooling tower motor all as specified and as directed Note :- (i) The spareswil be paid separately under respective items.

3

-

-

... More
Supply only Spares for carrying cooler tower of upto 125 TR water cooled chiller type central AC plant under relevant items :-

-

-

-

... More
PVC Fins 600x300x150mm.

100

-

-

... More
CT fan assembly cast aluminium alloy as per existing size.

1

-

-

... More
CT fan electric motor of capacity 2/3 HP with long shaft and blade, insulation class F, IP55 as per exisitng make.

1

-

-

... More
CT fan electric motor of capacity 5/7.5 HP with long shaft and blade, insulation class F, IP55 as per exisitng make.

1

-

-

... More
AI water sprinkler 2" to 5"

1

-

-

... More
FRP motor cover

1

-

-

... More
PVC branch pipes 63mm dia & 30 inch long 04 Nos

1

-

-

... More
M&L for leak testing of Air Conditioning Plant unit of comprising of condensor units and chiller units with pressure testing the complete plant by dry nitrogen gas by separating high side and low side, brazing and low side, rectifying the leakage by gas welding, brazing, pressure testing, vaccumising gas, gas charging the system with existing Refrigerant Gas, testing and commissioning complete all as specified and as directed by Engineer- in- charge of the following capacity of AC Plants are as under :- Note :- (i) Each Chiller unit, refrigerant gas will be paid and measured separately. (ii) The cost of the nitrogen gas shall be deemed to be included in the quoted rates.

-

-

-

... More
17 to 35 Ton

10

-

-

... More
70 to 100 Ton

15

-

-

... More
M&L for Dismantling the pump of following capacity, isolating suction/ delivery line connections, checking the worn out parts like impeller, shaft, stuffing box, shaft sleeve using micrometer and transporting to workshop for repairs, checking the conditions of bearings removing scales from impeller and pump housing, building the worn out metal of transmission shaft to required level, machining to the required size on lathe machine, grinding and finishing to match the sleeve and fixing into the housing, re- assembling, transport back to the installation, installing in position, check for alignment with dial gauge, inserting shims where necessary, refixing with coupling, tightening with torque wrench to required level, re- connecting the flanged pipe connections of suction,/ delivery, greasing for bearings including replacement of rubber insertion etc complete all as specified and directed: - Note:- Spares will be measured and paid separately under relevant schedule

-

-

-

... More
2 to 3 HP

6

-

-

... More
5 to 7.5 HP

5

-

-

... More
Supply only Spares for carrying cooler tower of upto 125 TR water cooled chiller type central AC plant under relevant items :-

-

-

-

... More
Shaft brushes with check nuts (stainless steel) for 2 to 3 HP Pump.

1

-

-

... More
Shaft brushes with check nuts (stainless steel) for 5 to 7.5 HP Pump.

1

-

-

... More
Ball bearings suitable for 2 to 3 HP Pump.

1

-

-

... More
Ball bearings suitable for 5 to 7.5 HP Pump.

1

-

-

... More
Metal coupling suitable for 2 to 3 HP Pump.

1

-

-

... More
Metal coupling suitable for 5 to 7.5 HP Pump.

2

-

-

... More
Gland packing end cover (Stainless steel of suitable grade) as per exiting make

2

-

-

... More
M&L or dismantling the defective induction motor of following capacity/ make/ class of insulation from foundation bed, disconnecting all electric supply connections, duly coupled with pump/ compressor, transporting to workshop removing burn out winding from starter/ rotar, rewinding with suitable gauge of super enamelled copper wire of approved make and replacing DE/ NDE bearings, insullation materials, varnishing, heating, greasing of bearings etc complete re- assembling, testing and commissioning of following motors all as directed including terminal block, bearings of motor complete all as specified and directed by Engineer - in- charge.

-

-

-

... More
3 to 5 HP

6

-

-

... More
7.5 to 10 HP

6

-

-

... More
M&L for Disconnecting, cutting and taking out unserviceable sealed unit compressor of package type air conditioner any make & model including removal, fitting/fixing of serviceable sealed unit compressor soldering, welding, brazing as required including charging of refrigerant gas and oil in the exchanged compressor, making electric & mechanical connections at site and testing on load, complete of the following capacity:-.

-

-

-

... More
5.5 Ton

4

-

-

... More
7.5 to 8.5 Ton

4

-

-

... More
12.5 Ton

4

-

-

... More
Supply only compressor of package type air conditioner complete of the following capacity:- (Make : Kirloskar / Copland / Danfoss.) NOTE:- (i) Micro processor based control comprising for following features- (a) Automatic capacity control reducing energy consumption. (b) Micro processor based sequence of starting / stopping of equipment with fixed time delay. (c) Alarm history giving cause of tripping. (d) LP/HP cut out. (ii) Fail safe features comprises the following:- (a) Under voltage protection (b) Single phase protection (c) Over load protection (d) Phase inbalance protection (e) Anti freeze protection (f) Power loss trip and shut down (iii) Set of water flow switches in condenser and chiller water line at intel and oulet. (iv) First charge of refrigerant gas and compressor oil as per manufacturer's recommendation.

-

-

-

... More
5.5 Ton

4

-

-

... More
7.5 to 8.5 Ton

4

-

-

... More
12.5 Ton

4

-

-

... More
S&F, Pre filter in sheet metal frame IN REPLACEMENT complete. of following size:-

-

-

-

... More
24″ x 24″ x 2″

30

-

-

... More
21"x21.5"x2''

25

-

-

... More
S&F, Expansion valve, Capacity 5/7.5/11/15/25 Ton IN REPLACEMENT complete all as directed.

8

-

-

... More
S&F, Solenoid valve, Capacity 5/7.5/11/15/25 Ton IN REPLACEMENT complete all as directed.

7

-

-

... More
S&F, V belt, IN REPLACEMENT complete. of following size:-

-

-

-

... More
A-29/30

20

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.