Military Engineer Services Tender

... More
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Military Engineer Services - MES Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date22 May 2025
Closing Date19 Jun 2025
Tender Amount₹ 6,34,00,000 
Notes
Download

AI Insights

Class Of Bidder
... View More
The eligible class required by a bidder to participate or bid in the tender is 'A Class' and above, and also 'Class of Contractor'. Additionally, for term contracts, the class required is 'Class SS to E'.
Technical Capacity
... View More
The required prior work experience for the bidder includes satisfactorily completing requisite value works with certain government entities, such as Central/State Government, Central/State PSUs, AWHO, AFNHB, CGEWHO, and DGMAP. However, specific values like amount and percentage are not mentioned. The bidder should have completed works with a value that meets the requirements, but the exact details are not provided. Contractors of one class below the eligible class should have previously completed similar works satisfactorily to be considered for the tender. The bidder is required to submit details of works completed and under progress, including the value of the work, but no specific percentage or amount is specified as a requirement. The value and percentage of similar works completed are not mentioned.

Costs

Summary

Special Repair To Jcos/ors Md Accn At Lalgarh Jattan Mil Stn

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Demolition of floor hearth or wall tilling including cement mortar bedding but not backing including removing rubbish material from building and thrown in low lying empty area outside of MOD land from the site complete all as specified and as directed by Engineer-in-Charge.

7186.94

-

-

... More
Taking down cement or cement plaster from brick wall etc including racking out joints, hacking for key & scrubbing down with water etc including removing rubbish from the site to outside of MOD land complete all as specified and directed by Engineer-in-Charge.

12956.77

-

-

... More
Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc and laided, bedded and pointed in any mortar complete all as specified and directed by Engineer-in-Charge.

65.5

-

-

... More
Material and labour for Double charge vitrified coloured tiles (approved shade) of size 600mm x 600mm having thickness 8 to 9 mm premium (1st) quality having water absorption less than 0.08%, straight edge, stain free, glossy finish, square marbonite, laid as in floor, set and jointed using type-I adhesive (thick bed fixing) conforming to IS-15477:2004 and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, complete all as specified and directed by Engineer-in-Charge. Make : Johnson (Snow Flair/Albano White Plus/Albano Lemon Plus) or Techno commercial equivalent in make mentioned in Appendix 'B'

3222

-

-

... More
All as per Ser item No 7.00 here in before but as in skriting, but tiles laid over and including 10 mm thick rendering layer in cement mortar(1:3) complete all as specified and as directed by Engneer -in-Charge

336

-

-

... More
Material and labour for 7 to 8 mm thick non-skid ceramic colour (light shade) joint free tiles with matt finish premium (1st) quality having water absorption should be between 3% to 6%, square/ rectangular, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floor, set and jointed using type-I adhesive (thick bed fixing) conforming to IS-15477:2004 including necessary cutting as per site requirement, complete all as specified and as directed by Engineer-in-Charge.

721.6

-

-

... More
Material and labour for Providing and Laying Premium (1st) quality having water absorption should be between 10% to 20%, digitally printed straight edge, punched, glazed ceramic rectangle tile in approved shade and finish with flexural strength greater than 16 N/mm2, scratch hardness on Moh’s Scale minimum 3 and crazing resistance of 2 cycles in coloured tiles 600 X 300 mm and 7 mm thick, in any pattern of light & dark/highlighters tiles etc as approved, on vertical surfaces such as in skirting/dado etc, set and jointed in cement slurry over & including 10 mm thick rendering in cement mortar (1:4) and pointed in white cement with pigment to match the colour of tiles complete all as specified. Note : Dado should be flushed with the wall plastering. Make : Johnson (Digital HD Tiles) (Barstow DK/LT/HL for Toilets & Verona LT/HL for Kitchens) or Techno commercial equivalent in make mentioned in Appendix 'B'

2907.34

-

-

... More
Material and labour for Rajasthan black granite (Telephonic Z-black) , 20 mm thick including bull-nose the front length, machine cut as in shelves/steps/cills/jambs/skirting/border only in flooring and the like works etc, set and jointed in cement slurry over & including screed of 15 mm thick rendering/screed in cement mortar (1:4) and pointed in cement mixed with pigment to match the shade of slab including rubbing, cutting and mirror type granite polishing complete all as specified and as directed by Engineer-in-Charge. Note : Single piece should be used in steps/cills/jambs/shelves.

205

-

-

... More
M&L, for Pre polished kota stone slab flooring, 20-25mm thick over and including 20 mm thick (1:4) cement screed base laid and jointed With grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed by Engineer-in-Charge..

252

-

-

... More
Material and labour for Pre polished Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over and including 15mm thick (1:4) cement screed/rendering laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed by Engineer-in-Charge.

18

-

-

... More
Material and labour for anti skid full body vitrified step tiles Premium (1st) quality, 10mm thick bull noses and self embossed or grooved as in treads & landing/riser or skirting (single piece length wise upto 1200mm) laid over and including screed bed 10 mm thick in CM 1:4 complete all as specified and as directed by Engineer-in-Charge.

180

-

-

... More
Material and labour for applying 10mm thick rendering /screed in cement mortar (1:4) including mixing of liquid WPC in mortar @ as per manufacturer instruction per bag of cement of 50kg and finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge. (Note :- WPC shall be measured & paid separately as Supply only under relevant item of BOQ).

8388.51

-

-

... More
M&L for rendering 15mm thick in cement mortar 1:6 on other than fare face of brick work or concrete surfaces and finishing the surface even & smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge.

2820.66

-

-

... More
M&L for rendering 5mm thick in cement mortar in 1:3 on ceiling finish even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge.

1747.6

-

-

... More
Material and labour for Preparation of new plastered External wall surface and after preparing the surfaces apply the following complete all as specified and as directed by Engineer-in-charge:- (a) Applying Wall care putty 1mm thick on wall surface and smoothening the surfcae with sand papers / Mechanised sanding etc prepratory to paint as directed. (b) M&L two coat of Exterior Acrylic emulsion(weather coat) over a coat of primer priming by using Airless spray / Roller over @ 5.0 sqm/ltr per two coats complete all as specified. Notes : (i) The prepared surface after wall putty, the contractor will inform to the GE as well as to the Engineer-in-Charge for site inspection before applying further external finishes. Please note that the further external finishes work will start only after approval of the prepared surface from the GE as well as to the Engineer-in-Charge through site order book.

8388.51

-

-

... More
Material and labour for Preparation of new plastered Internal wall surface and after preparing the surfaces apply the following complete all as specified and as directed by Engineer-in-charge:- (a) M&L Wall care putty 1mm thick on wall surface and smoothening the surface with sand papers / Mechanised sanding etc prepratory to paint as directed. (b) M<wo coats of acrylic distemper (with at least 3 year durability/performance warranty) over a coat of primer by using Airless spray / Roller over @ 12 sqm/ltr per two coats and primer @ 10 sqm/ ltr per one coat . Notes : (i) The prepared surface after wall putty, the contractor will inform to the GE as well as to the Engineer-in-Charge for site inspection before applying further external finishes. Please note that the further external finishes work will start only after approval of the prepared surface from the GE as well as to the Engineer-in-Charge through site order book.

2820.66

-

-

... More
Material and labour for Preparation and applying three coats of white wash on new plastered or concrete surface of ceiling surface by making the lime slaked at site and shall be mixed and stirred with about five liters of water for 1 kg of unslaked lime to make a thin cream. This shall be allowed to stand for a period of 24 hours and shall then be screened through clean coarse cloth. 1 kg of gum dissolved in hot water shall be added to every one cubic meter of lime cream. About 1.3 Kg of sodium chloride dissolved in hot water shall also be added for every 10 kg of lime for making the coating hard and rub-resistant. Small quantity of ultramarine blue (upto 3 gm per kg of lime) shall also be added to the last two coats of white wash solution and the whole solution shall be stirred thoroughly before use complete all as specified and as directed by Engineer-in-Charge.

1747.6

-

-

... More
Material and labour for Preparation and applying one coat of white wash on old plastered or concrete surface of ceiling surface ditto all as per item no 20 above complete all as specified and as directed by Engineer-in-Charge.

3060.48

-

-

... More
Material and labour for complete removal of existing treatment of wall surfaces of any desciption, preperation of surface by Mechanised sander having suction vaccum Bag using Smart periodical methodology and after preparing the surfaces applying the following complete all as specified and as directed by Engineer-in-charge:- (a) Applying Wall care putty in two coats on wall surface and smoothening the surfcae with sand papers / Mechanised sanding etc prepatory to paint as directed by Engineer-in-charge . (b) Applying Two coats of acrylic distemper (with at least 3 year durability/performance warranty) of approved tint over a coat of primer by using Airless spray / Roller Note : Contractor may use manual scraping tools for complete removal and surface prepration with prior approval of Engr-in-chrge in case of places where using of Mechanical equiment are not posiible.

12418.45

-

-

... More
Material and labour for preparation of old painted steel surfaces of any description not otherwise described over 10cm width or girth by cleaning the dust and removing all loose particle with using sanded paper, clean cloths and dry paint brush & applying one coat of synthetic enamel paint (1st quality) of approved tint/colour to achieve glossing finish with using paint brush complete as specified and as directed by Engineer-in-Charge.

75.6

-

-

... More
Demolition of cement concrete (unreinforced) in ground floor and paving not exceeding 15cm thickness below or above ground level of any description and in any position including removing rubbish material from building and thrown in low lying empty area outside of MOD land from the site complete all as specified and as directed by Engineer-in-Charge

64.71

-

-

... More
Material and labour for 75 mm thick PCC (1:3:6) type C-2 using 40mm graded mechanically crushed stone aggregate as in plinth protection finished even and smooth without using extra cement with & including 10mm wide, 30mm deep joints at the rate of 3 mtr centre to centre and at every turning & filling the joints with bitumen & sand mixture complete all as specified and as directed by the Engineer-in-Charge.

478

-

-

... More
Material and labour for water proofing treatment to RCC sunken slab and adjoining vertical slab shall be carried out through authorized applicators approved by GE any one of the two methods as specified below:-

116.03

-

-

... More
Method 1 (A) Supplying and applying two component elastomeric acrylic polymer modified cementitious waterproofing coating, Smart Care Damp proof 2K, having 100% elongation as per ASTM D412, resisting 5 bars hydrostatic pressure as per DIN 1048, reduction to rapid chloride shall be 70 as per DIN 1048, crack bridging upto 1.2mm as per ASTM 4548.5 Clean all working surface & made free from dirt, grease laitance etc. After inspection for all working area rough surface, cracks & construction joint are treated by polymer modified mortar of 1:1:4 (1 Cement : 1Polymer : 4 Sand). Making Gola of size 75x75mm at junction of vertical & horizontal with the polymer modified mortar of 1:1:4 (1 Cement : 1 Polymer : 4 Sand). The coating shall be terminated at 1600mm in toilet/2100mm in bathroom on vertical walls. The mixing ratio of the coating shall be 2 parts of powder & 1 part of liquid without any water addition in the mixing and shall have consumption of 1.5kg/sqm per coats, etc, complete as per manufactures specifications. (B) Bore Packing: All the borehole gaps between concrete surface and PVC pipe of various dia upto the neck level shall be filled with non-shrink free flow grout – Smart Care GP Grout having dual shrinkage compensation property. Before the bore packing, surface of the PVC pie and concrete surface will be made rough and sand will be sprinkled with polymer bonding agent. (C) Apply12-15mm plaster on slab and vertical surface admixed with Smart Care Vitalia Neo @200ml per bag of cement before treatment.

-

-

-

... More
Method 2 (A) Supplying and applying two component cementitious & acrylic flexible water proofing & protective coating, two coats with 1mm DFT, having Hydrostatic (positive) water pressure resistance (DIN 1048) is 7. Abrasion resistance, cm/km is 0.09 of Dr Fixit Pidifin 2k @ 1.5kg/sqm with a paint brush over existing slab surface and adjoining vertical surface. The Polyester reinforced coated net of 45g/sqm, 2.5mmx2.5mm is laying on the surface immediately on the first coat of two component modified polymer Dr Fixit pidifin 2k. After removal of all lose materials like dust etc. with wire brush coir brushes from surface to get absolutely cleaned surface free of foreign contaminant filling of crack and patches with polymer based mortar/micro concrete, after that making the gola on surrounding wall’s junction and seal the vertical walls. In case of core cutting on the surface, the joint is seal with non-shrink grout. (B) The coating shall be terminated at 1600mm in toilet/2100mm in bathroom on vertical walls. (C) Apply12-15mm water proof plaster on slab and vertical surface admixed with Dr Fixit pidiproof LW+ @200ml per bag of cement before treatment.

-

-

-

... More
Make : Method 1 (Asian paint)/ Method 2 (Dr fixit) or Techno commercial equivalent in make mentioned in Appx 'B' approved by CWE Note :- (i) The treatment shall be carried out by authorised applicator (through specialized agency ) approved by CWE as per the manufacturer. (ii) PCC filling under sunken area will be measured & paid separately (iii) Treatment should be conitue upto 450mm height on vertical wall of sunken but only plan area of sunken will be measured for payment.

-

-

-

... More
Material and labour for water proofing treatment to walls surfaces of toilets/baths/WC's (1600mm in toilet and 2100mm in bathroom on vertical wall surface) with following applications complete all as specified and as directed by Engineer-in-Charge :- (a) Applying first coat of chemical pidifin 2K (Dr Fixit) on cleaned surfaces @ 0.86 Kg/Sqm (Minimum) and drying for 24 Hours (b) Applying second coat of chemical Pidifin 2K (Dr Fixit) @ 0.86 Kg/Sqm (minimum) over first coat Make : Dr fixit or Techno commercial equivalent in make mentioned in Appx 'B' approved by CWE

1065.18

-

-

... More
Supply only Liquid water proofing compound ISI marked confirming to IS 2645 - 2003 complete all as specified and as directed by Engineer-in-Charge

311.38

-

-

... More
Material & Labour for PCC (1:5:10) type E2 using 40mm graded stone aggregate as filling of sunken floors complete all as specified and as directed by Engineer-in-charge.

46.41

-

-

... More
Material & Labour 40 mm GI pipe medium grade, with all fittings and fixed to walls and ceilings and laid in floors made to shape as in spout pipe in sunken/ verandah/ Balcony complete all as specified and as directed by Engineer-in-charge.

36.9

-

-

... More
Removal of existing PCC/Brick tiles/bat coba / mud phuska/APP membrane from the roof stacking the resusable material and disposal of unserviceable rubbish outside the campus as direction by engineer in charge but outside 3 km. 15 mm thick rendering in CM 1:4 over existing /old RCC slab / surfaces after dismantling /demo / taking down existing roof treatment. Cleaning of surface of loose dust, and dirt and cement sullry etc by mean of wire briush ,dust removing brush and scrapper etc. Pot holes / cracks shall be repaired with cement admixed with polymer as per manufacturer instruction. Providing PCC coving / gola along vertical parapets of size 75 x75 mm with concrete Mix (1:2:4) , type B-1 using water proofing compoung of approved make etc . complete as directed by engineer in charge .

2265

-

-

... More
The surface shall be treated with PU Elastoseal primer with Epoxy primer to seal the pores and enhance the adhesion of the coating , supplying and applying single component water proofing liquid membrane based on pure, elastomeric, polyurethane resin cold aplied of spray /brush applied membrane with an elogation of 650% + 50 and tensile strength not less than 2 MPA , crack bridginfg ability not less than 2mm , No leakage upto 5 bars of water pressure . Shore hardness > 50 shore. The minimum thickness to be applied shall be 1.5 mm , (overall) in two layers (each layer 750 micron) or as per manufacturers instructions so as to achive thickness not less than 1.5 mm. Providing and laying of protactive Geotextile fabric 150 GSM over the entire membrane with proper overlape of 75mm before laying SRI tiles. Providing and laying SRI (sun resistance index ) roof tiles size 300x300x9- 10 mm with 20 mm thick cement plaster in CM (1:4) mixed with liquid water proofing compound as per manufacturers instruction confirming to required slope . Makes of PU primer/membrane SIKA/ BASF, BERGER/STP FOSROC /SAINT GOBAIN PIDILITE. (C) Apply12-15mm plaster on slab and vertical surface admixed with Smart Care Vitalia Neo @200ml per bag of cement before treatment.

-

-

-

... More
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 sqm each and removing from site including cutting holes for removal of old rusted hold fast and prepare the surface for new hold fast complete all as specified and as directed by Engineer-in- charge.

746

-

-

... More
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4 Sqm each and removing from site including cutting holes for removal of old rusted hold fast and prepare the surface for new hold fast complete all as specified and as directed by Engineer-in- charge.

574

-

-

... More
S&F Stainless steel fancy type peg set of six and fixed in position with steel screws complete all as specified and directed.

246

-

-

... More
S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately)

2484

-

-

... More
S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately)

918.4

-

-

... More
S&F for Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 35 mm thick size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. including supply and fixing following items :- (a) Stainless steel (304 Grade) Finished butt Hinges 100 mm, 4 Nos per leaf and table 6 of BIS 12817-2020 BIS Marked. (b) Stainless stell (304 Grade) finished square tower bold 200 mm long-2 Nos per leaf as per table 01 dia of bolt 12 mm as per BIS 12833. (c) Stainless steel (304 Grade) Finished Handles 200 mm-2 Nos per leaf. (d) Stainless steel (304 Grad) finished siliding bold 300 mm-1 No per leaf, 16 mm dia as per BIS clause (iii) of BIS 15834-2020. (e) Stainless steel (304 Grade) Finished Floor door stoper-1 Nos per leaf.

1025.74

-

-

... More
S&F for Factory made single extruded WPC (Wood PolymerComposite) glazed and skeleton plain door shutter of 35 mm thick size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. Including supply and fixing of stainless steel 304 Grade (natural finish) wire cloth complete all as direction of Engineeer-in -Charge indluding supply and fising of following items :- (a) Stainless steel (304 Grade) Finished butt Hinges 100 mm, 4 Nos per leaf and table 6 of BIS 12817-2020 BIS Marked. (b) Stainless stell (304 Grade) finished square tower bold 200 mm long-2 Nos per leaf as per table 01 dia of bolt 12 mm as per BIS 12833. (c) Stainless steel (304 Grade) Finished Handles 200 mm-2 Nos per leaf. (d) Stainless steel (304 Grade) finished siliding bold 300 mm-1 No per leaf, 16 mm dia as per BIS clause (iii) of BIS 15834-2020. (e) Stainless steel (304 Grade) Finished Floor door stoper-1 Nos per leaf. (f) Stainless steel (304 Grade) wire cloth fixing as per manufacturer's instructions

533.75

-

-

... More
S&F Factory made single extruded WPC (Wood Polymer Composite) solid door frames/ Chowkhat of size 45 x 85 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately)

1151.28

-

-

... More
Supply & fixing HDHMR Board , 18/19mm thick both side decorative laminated, density over 850kg/cum, having a class A fire rating, grade 2 quality, interior grade, including fixed with screws , L bend or necessary fittings to mount on wall or to frame work as in Kitchen cup board Shutter / shelves / cabinet etc complete all as per direction of Engineer- in-Charge

291.1

-

-

... More
Supply and fixing Magnetic catcher fixed with steel screw complete all as specified and as directed by Engineer-in-charge.

328

-

-

... More
Supply & fixing Continuous (piano) hinges, stainless steel, bright finish, width of flap when open 30mm complete all as specified and as directed by Engineer-in-charge .

229.6

-

-

... More
Supply & fixing Drawer handles, projection drop 65mm on screwed plate complete all as specified and as directed by Engineer-in-charge .

328

-

-

... More
S&F for Factory made single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of 24 mm thick size comprising of virgin polymer of K value 57-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 550 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. including supply and fixing following items :- (a) Stainless steel (304 Grade) Finished butt Hinges 100 mm, 4 Nos per leaf and table 6 of BIS 12817-2020 BIS Marked. (b) Stainless stell (304 Grade) finished square tower bold 150 mm long-2 Nos per leaf as per table 01 dia of bolt 12 mm as per BIS 12833. (c) Stainless steel (304 Grade) Finished Handles 100 mm-2 Nos per leaf

259.78

-

-

... More
Supply & fixing aluminium (extruded section body) Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed (IS Marked) complete all as per direction of Engineer- in-Charge

246

-

-

... More
Supply & fixing hasp and staple, safety type of aluminium anodised 100mm size fixed with screw complete all as specified and directed by Engineer - in - Charge.

164

-

-

... More
Supply & fixing factory made UPVC sliding window three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm) with or without provision of opening for cooler as directed including all fittings, steel roller system, locking arrangement etc., making arrangement for fixing of hardware, glass, wiremesh, grill etc all as per manufacture instruction and Drg No BTD-890/R and as directed. Note : (i) The unit rate quoted by contractor includes cost of all connected accessories except glass and wire mesh. Glass and wire mesh shall be measured and paid separately. Net Opening will be measured for payment purpose. Provision of all other items as shown on Drgs & Cutting holes of suitable depth in wall for inserting lugs etc including making good dismantled portion with PCC (1:2:4) type B-0 using 12.5mm graded crushed stone aggregate and cement mortar (1:3) shall be demand to be include (ii) The width /height as shown in drawing are tentative, however the same shall be adjusted as per actual opening at site. Design and pattern of window will be decided by GE as per site requirement during execution at site.

353.4

-

-

... More
Supply & fixing factory made UPVC window or ventilator side hung/top hung (glazed and gauge both) made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm) including all fittings like hinges, tower blot, peg stay, locking arrangement etc., making arrangement for fixing of hardware all as per manufacture instruction and refer Drg No BTD-890/R complete all as specified and directed. Note : (i) The unit rate quoted by contractor includes cost of all connected accessories except glass and wire mesh. Glass and wire mesh shall be measured and paid separately. Net Opening will be measured for payment purpose. Provision of all other items as shown on Drgs & Cutting holes of suitable depth in wall for inserting lugs etc including making good dismantled portion with PCC (1:2:4) type B-0 using 12.5mm graded crushed stone aggregate and cement mortar (1:3) shall be demand to be include (ii) The width /height as shown in drawing are tentative, however the same shall be adjusted as per actual opening at site. Design and pattern of window will be decided by GE as per site requirement during execution at site.

44.28

-

-

... More
Supply & fixing 5.00 mm thick sheet glass ordinary quality in squares / retangular not exceeding 0.5sqm in each pane (window/ ventilator) complete all as specified and as directed by Engineer-in- charge. Note :- Cost for fittings and rubber beading for securing the glass shall be included in main item of window/ventilator of BOQ.

247.6

-

-

... More
Supply & fixing 5.00 mm thick figured glass pin head type in squares / retangular not exceeding 0.5sqm in each pane complete all as specified and as directed by Engineer-in- charge. Note :- Cost for fittings and rubber beading for securing the glass shall be included in main item of window/ventilator of BOQ.

22.14

-

-

... More
S&F Stainless steel wire cloth 0.36 mm nominal dia of wire and avarage width of aparture 1.40mm and fixed etc., complete all as specified and as directed by Engineer-in- charge

246

-

-

... More
Material and labour for reinforced cement concrete (1:2:4) (nominal mix) type B-1 using 20mm graded stone aggregate as in slabs supported on walls, beams and columns landing, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by Engineer-in-Charge. (NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule.

9.21

-

-

... More
Material and labour for mild steel TMT bars 10mm dia and over cut to length bent to shape, required including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge. (NOTE : Weight of binding wire shall not be considered for measurement and payment purpose.)

6443.28

-

-

... More
Material and labour for form work to soffits of suspended slabs such as flat roof slabs, floor slabs, shelf slab, landings and similar work not exceeding 200mm thick (horizontal or sloping) rough finished complete all as specified and as directed by Engineer-in- charge.

351.82

-

-

... More
S&F Framed work such as grills, gratings coolar stand, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 including dismantling of existing complete all as specified.

9500

-

-

... More
M&L for preparation of new steel surfaces of any description over 10cm width or girth and applying a coat of red oxide zinc chrome primer and two coats of synthetic enamel paint (for steel surfaces) including preparation of surface complete all as specified.

400

-

-

... More
M&L for welding in repairs Thickness of metal to be welded will be not exc 6 mm complete all as specified and as directed by Engineer - in - Charge.

2

-

-

... More
Material and labour for 40mm thick cement concrete (1:2:4), type B-1 using 20 mm graded stone aggregate as in flooring, hard standing etc, and surface finished even & smooth without using extra cement including necessary form work complete all as specified and as directed by Engineer-in-charge.

721.6

-

-

... More
Taking up or down existing galvanised steel water tubing (GI pipe) 15mm bore including fitting/connection from wall, ceiling, floor etc. complete all as specified and as directed by Engineer-in-charge.

860

-

-

... More
Taking up or down existing galvanised steel water tubing (GI pipe) 20mm bore including fitting/connection from wall, ceiling, floor etc. complete all as specified and as directed by Engineer-in-charge.

1230

-

-

... More
Supplying and laying of 20 mm (Outer dia) CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed by Engineer-in-charge.

1516

-

-

... More
Supplying and laying of 25 mm (Outer dia) CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed by Engineer-in-charge.

1886

-

-

... More
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed by Engineer-in- Charge

1516

-

-

... More
Supply & fixing rotational moulded polyethylene water storage tank white colour of capacity 500 litres (cylindrical vertical, triple layered with closed top), hoisted and fixed in position including making inlet and out let connection including dismantling/taking down of existing unserviceable PVC water storage tanks of any description and capicity complete all as specified and as directed by Engineer-in-charge.

50

-

-

... More
Taking down and refixing old 500 ltrs capacity Rotational moulded polyethylene water storage tank after cleaning and removing all scale and dirt etc from tanks and from mouth of circulating pipes etc inclubing 20 mm ball valve complete all as specified and directed by Engineer-in- Charge

32

-

-

... More
S&F 20 mm ball valves high pressure of PTMT with epoxy coated aluminium rod & hihdesity plastec ball screwed for iron pipe and fixed. (Minimum weight 20mm - 210 gms) etc complete all as specified and directed by Engineer-in- Charge.

50

-

-

... More
Supply and fixing CPVC globe or gate valve (ISI marked), heavy duty, plain both ends suitable for 20mm bore iron pipes and including CPVC solvent cement for jointing complete all as specified and as directed by Engineer-in-charge.

164

-

-

... More
Supply and fixing in repair bib tap cast copper alloy, chromium plated, fancy type with crutch or butterfly handle with capstan head or round head/knob, screwed down, screwed for iron pipe or for brass ferrule 15mm bore complete all as specified & directed by Engineer-in-charge. Note :- The minimum weight shall be as given in SSR or in relevant IS.

82

-

-

... More
Supply and fixing sink mixer valve 15mm bore, brass chromium plated, for mixing hot & cold water, screwed down for iron pipe suitable for fixing to wall, complete all as specified and as directed by Engineer-in-charge. Note :- The minimum weight shall be as given in SSR or in relevant IS.

82

-

-

... More
Supply and fixing mixer valve 15mm bore, brass chromium plated, for mixing hot & cold water, complete with fittings for WHB complete all as specified and as directed by Engineer-in-charge. Note :- The minimum weight shall be as given in SSR or in relevant IS.

164

-

-

... More
Supply and fixing in repair single lever High concealed diverter flow consisting of exposed part kit with operating lever, wall flange & button and concealed body, cartidge sleeve and also including bath spout with flange chromium plated ,screwed down, high pressure complete all as specified and as directed by Engineer-in-charge. Make Cera:(exposed part F1018721, concealed part F4030101, bath Spout F1020661) or Techno commercial equivalent in make mentioned in Appendix 'B'

82

-

-

... More
Supply and fixing concealed stop cock cast copper alloy, chromium plated, fancy type, long shank and cup, screwed both ends suitable for 15mm bore iron pipe complete, all as specified & directed by Engineer-in-charge. Note :- The minimum weight of stop valve/stop cock shall be as given in SSR or in relevant IS.

82

-

-

... More
Supply and fixing in replacement concealed stop cock cast copper alloy, chromium plated, fancy type, long shank and cup, screwed both ends suitable for 15mm bore iron pipe complete, all as specified & directed by Engineer-in-charge. Note :- The minimum weight of stop valve/stop cock shall be as given in SSR or in relevant IS.

82

-

-

... More
Supply and fixing 15 mm bore chromium plated Angular stop valve of cast copper alloy screwed down high pressure with on/off handle screwed end for iron pipe or for unions and fixed complete all as specified and as directed by Engineer-in-charge. Note :- The minimum weight shall be as given in SSR or in relevant IS.

82

-

-

... More
Supply and fixing in replacement and repair 15 mm bore chromium plated Angular stop valve of cast copper alloy screwed down high pressure with on/off handle screwed end for iron pipe or for unions and fixed complete all as specified and as directed by Engineer-in-charge. Note :- The minimum weight shall be as given in SSR or in relevant IS.

246

-

-

... More
S & F in repair PVC connection 15 mm size with PTMT nuts of length 600 mm of approved quality complete all as specified

246

-

-

... More
Supply and fixing Plate Rack / Dish Rack of overall size 750mmx600mmx250mm (Approx size), glossy finish made out of Food Grade Stainless Steel 1mm thick sheet/strip including necessary arrangements for plates and utencils to keep (Holds up to many plates or bowls To accommodate several place settings, Multipurpose), stylish modern streamline design, rust resistant, easy to assemble and clean including fitting accessories fixed in position as directed with SS screws/fasteners etc complete all as directed by Engineer-in-charge.

82

-

-

... More
Supply and fixing stainless steel sink with drainage board, AISI 304 quality grade, 1.00 mm thick, glossy finish, for kitchen with plugs washers and CP waste coupling of 32mm dia and including cantilever cast iron brackets, connecting union, etc, overall size 915mm x460/928mmx458mm with bowl size 410x 355x185mm/430x355x200 including bottle trap 32mm with 125mm & 175mm long with wall connection pipe & wall flange and making good disturbed portion in CM 1:3 or PCC 1:2:4 complete all as specified and as directed by Engineer-in-charge. Make : Sink :- Nirali (Elegance) or Diamond (REK 3618) or Neelkanth Make : Bottle Trap :- Hindware (F850015) or Techno commercial equivalent in make mentioned in Appendix 'B'

82

-

-

... More
Supply & fixing in replacement corner wash hand basin of size 450 x 390 mm vitrous China white flat back including brackets and cutting for and pinning in end of bracket or erecting stand including 32mm waste fittings, waste pipe, chromium plated with long screwed shanks & fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and as directed by Engineer-in-Charge.

148

-

-

... More
Supply & fixing in replacement vitreous china wash basins, size 550x400mm white flat back including bracket and cutting for and pinning in end of bracket or erecting stand including 32mm waste fittings, waste pipe, chromium plated with long screwed shanks & fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and as directed by Engineer-in-Charge.

16

-

-

... More
Supply and fixing vitreous china premium/1st quality wall hung water closet with P trap white/ivory/off white including connection to drain (or out going pipe) and to flushing pipe, antisyphonagee pipe,etc., and incl. plastic soft close seat cover as recommended by manufacturer for particular model closed pattern with flat bottom etc; and incl S&F of all necessary accessories set like rag bolts/gel gasket/hinges etc as recommended by manufacturer for fixing, packing and taking down existing of any description/size complete in all respect all as specified and as directed by Engineer-in-Charge Make : Jaquar (Continental Series-CNS-WHT-963N or Techno commercial equivalent in make mentioned in Appendix 'B'

164

-

-

... More
Supply and fixing concealed flushing cistern of PVC 8 ltr. cap with dual flushing system, valveless syphonic action type, with inlet/outlet, ball valve, float and including brackets and connection to pipe etc. and incl S&F of all necessary accessories/installation kit and 'S' type drain pipe connetion set for wall hung WC etc as recommended by manufacturer for fixing, packing and including S&F of actuator knob/flush plates and and taking down existing of any description/size complete in all respect all as specified and as directed by Engineer-in-Charge Make : Jaquar (Concealed Cistern-JCS-WHT-2400S, Flush Plate-JCP-CHR-812415) or Techno commercial equivalent in make mentioned in Appendix 'B'

164

-

-

... More
S&F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified and as directed by Engineer-in-Charge

164

-

-

... More
S&F in repair brass chromium plated shower rose 125 mm of size with arm and with or without swivel joints to steel pipe or union complete all as specified and as directed

82

-

-

... More
S&F in repair brass chromium plated tubular towel rail, 20 mm dia, D type, 60 cm long between flanges complete all as specified and as directed by Engineer-in-Charge.

164

-

-

... More
S&F chromium plated soap dish any type and fixed to plugs on wall with chromium plated brass screws complete all as specified and as directed by Engineer-in-Charge.

82

-

-

... More
S&F PVC bathroom cabinet mirror of size 450x350mm all as specified and directed by Engineer -in-charge

164

-

-

... More
Taking down rain water pipe and eaves gutters (any size and pattern) including all fittings heads shoes bends swan necks etc including cleaning or refixing or removal to store(measured overall as fixed along the centre line over fittings and accessories)

420.9

-

-

... More
Supply & fixing 110mm bore UPVC pipes grade 'B' single socketed in any length with rubber ring joints, fixed along walls with and including suitable size clamps/brackets (interval of 1m and pipe keeping 100mm away from wall ) of suitable size fixed with fasteners/nut bolts, joints fixed with pipe joint lubricant complete all as specified and as directed by Engineer-in- charge. Note:- Bracket, clamp, nut bolt, fastner, slotted channel etc shall be made of deep drawn low carbon steel material with hot dip zinc aluminium flake coated and fixed all as shown on BTD drawing cost for same shall deemed to be included in the quoted unit rate and nothing extra shall be admissible on this account. Note : UPVC pipe and fittings/fixture (i) The testing for leakage of pipe shall be done before connecting the pipes (ii) All pipes shall be minimum 4" away from walls fixed with GI bracket (iii) The gully trap shall be minimum 90 cm away from wall. (iv) Seperate pipes for each floor should be provided. (v) Sewage and drain system shall be seperate.

420.9

-

-

... More
Supply and fixing stainless steel pipe 25mm bore (as a curtain rod), wall thickness of pipe not less than 1mm and grade SS 202, fixed in position with brackets and knobs at both ends as per site requirement including taking down old existing curtain rods any description with accessories complete all as specified and directed. Note : The cost of brackets and knobs is deemed to be included in the quoted rate. Nothing extra shall be paid on this account.

1640

-

-

... More
Dismantling and disconnecting existing CI soil waste/vent pipe 100 mm bore fixed to wall,laid in trenches incl all fittings & accessories complete all as specified and as directed by Engineer-in-Charge.

298.2

-

-

... More
Dismantling and disconnecting of existing CI soil waste/vent pipe 75 mm bore fixed to wall,laid in trenches incl all fittings & accessories complete all as specified and as directed by Engineer-in-Charge.

285.6

-

-

... More
Supply & fixing 110mm bore uPVC pipes grade 'B' single socketed in any length with rubber ring joints, fixed along walls/tranches with and including suitable size clamps/brackets (interval of 1m and pipe keeping 100mm away from wall ) of suitable size fixed with fasteners/nut bolts, joints fixed with pipe joint lubricant including bends, socket , Y junction, Tee , cowl etc complete all as specified and as directed by Engineer-in- charge.complete including low carbon hot roll gauge corrected oil pickeled& drawn pipe supporting clamping system 32x3mm with rib and notch are hot dip galvanised and Zn, Al flake coating with necessary clamps to fix and hold pipe complete all as specified and directed. ( Note: Detail of Pipe supporting system is all as per Drg NO -BTD-916). Note:-UPVC PIPE AND FITTING / FIXTURE- (i) The testing for leakage of pipe shall be done before connecting the pipes (ii) All pipes shall be minimum 4" away from walls fixed with GI bracket (iii) The gully trap shall be minim um 90 cm awasy from wall.(iv) Seperate pipes for each floor should be provided (v) Sewage and drain system shall be seperate.

601.6

-

-

... More
Supply & fixing 75mm bore uPVC pipes grade 'B' single socketed in any length with rubber ring joints, fixed along walls/tranches with and including suitable size clamps/brackets (interval of 1m and pipe keeping 100mm away from wall ) of suitable size fixed with fasteners/nut bolts, joints fixed with pipe joint lubricant complete including bends, socket , Y junction, Tee , cowl etc all as specified and as directed by Engineer-in- charge.complete including low carbon hot roll gauge corrected oil pickeled& drawn pipe supporting clamping system 32x3mm with rib and notch are hot dip galvanised and Zn, Al flake coating with necessary clamps to fix and hold pipe complete all as specified and directed. ( Note: Detail of Pipe supporting system is all as per Drg NO -BTD-916) Note:-UPVC PIPE AND FITTING/ FIXTURE- (i) The testing for leakage of pipe shall be done before connecting the pipes (ii) All pipes shall be minimum 4" away from walls fixed with GI bracket (iii) The gully trap shall be minim um 90 cm awasy from wall.(iv) Seperate pipes for each floor should be provided (v) Sewage and drain system shall be seperate

449.6

-

-

... More
Supply & fixing in repair PVC (SWR) gully trap 125 X 125 mm, setting and jointing with solvent cement complete all as specified and as directed by Engineer-in- charge.

82

-

-

... More
Cutting in to existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for as specified dia of pipe 150mm complete all as specified and as directed by Engineer-in-Charge.

41

-

-

... More
S&F Brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed complete all as specified and as directed by Engineer-in-Charge.

164

-

-

... More
M& L for Writing letters or figures (Block.Roman, Italic or Indian) n exc. 30 cm high complete all as specified.

67.2

-

-

... More
Carefully chipping, removing existing loose/ damaged concrete with plaster from Roof, Ceiling, Chajja, Fascia, Fins, Drops and similar items by low impact high frequency hammer/ chipper without damaging the existing sound concrete and exposing old reinforcement upto 10mm beyond corroded reinforcement bars using electrically operated diamond concrete saw blade, making the edges straight and even and cleaning it by wire brush and then by air blower and removal of rubbish outside MoD land complete as specified and as directed by Engr-in-charge.

208.05

-

-

... More
Cleaning all existing reinforcement bars in Roof, Ceiling, Chajja, Fascia, Fins, Drops and similar items with wire brush/rotary wire brush to make entire circumference surface of bars free from rust scales, loose material, dirt etc., complete and applying alkaline rust converting primer on the existing rebar and allowing it to react with rust for 6 hrs and form a corrosion resistant, insoluble and adherent protective layer including cleaning the reinforcement, wire brushing to remove the rust spalls, complete as per manufacturers instructions, all as specified and directed. (Mode of measurement: per sqm of breaking area of concrete.) Make: Sika- Rustoff 100/Fosroc- Reebaklens RR/OM AGRO- DERUSTER/ Pidilite Dr Fixit Rust Remover, Asian Paints Apcorep rust remover or Techno commercial equivalent make approved by GE in writing from E-in-Chief Br approved list.

208.05

-

-

... More
Providing and application of Zinc rich epoxy anti-corrosive protective coating for reinforcement bars as corrosion protection system in 2 coats to the entire circumference surface of bars (consumption Qty as per manufacturers instructions but min 0.4 kg/Sqm approx) in beams complete all as specified and directed by Engr-in-charge. The product should confirm carbonation resistance of 2 mm and bond strength > 1N/sqmm according to ASTM C 882-78 (Mode of measurement: per sqm of application area of concrete.) Make: Sika- Friazinc R/ Fosroc- Nitozinc Primer/ Pidilite Dr Fixit Zinc Rich Primer Asian Paints Apcorep rust coat RB or Techno commercial equivalent make approved by GE in writing from E-in-Chief Br approved list.

208.05

-

-

... More
Apply SBR based bonding agent to the entire concrete surface prior to building up of concrete with Polymer modified mortar or any other treatment , including cleaning the surface to remove dirt, dust or any other impurities on the surface, etc. complete in Roof, Ceiling, Chajja, Fascia, Fins, Drops and similar items. Make: Sika - SikaDur 32 LP/ Fosroc - Nitobond SBR (EP)/ Pidilite Dr Fixit Super Latex (EP) Asian Paints Repair Polymer or Techno commercial equivalent make approved by GE in writing from E-in-Chief Br approved list.

208.05

-

-

... More
Rebuilding the section of structural damaged RCC/PCC elements of Roof, Ceiling, Chajja, Fascia, Fins, Drops repair to spalling concrete to its original size and shape , layer of 10mm average thickness by providing and applying with pre-batched, one component fiber based repair mortar having compressive strength >= 50 N/sqmm (28 days) according to ASTM C 109; flexural strength >= 5N/ sqmm (7 days) according to ASTM C 293-79. complete all as specified and as directed by Engineer-in-charge Make: Sika - Monotop 122 F/ Fosroc - Renderoc S2/ Pidilite Dr Fixit Polymer Mortar HB or Techno commercial equivalent make approved by GE in writing from E-in-Chief Br approved list.

-

-

-

... More
All as per item no 103.00 here in before but for10mm Average thickness in 1st layer.

208.05

-

-

... More
All as per item no 103.00 here in before but for each addl 10mm uniform thickness for subsequent layers

208.05

-

-

... More
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. Or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and as directed.

335.39

-

-

... More
Returning, filling in, including spreading levelling including watering & well ramming in layers n. exc 25 cm all complete as specified in soil complete all as specified and as directed.

164.49

-

-

... More
Removing excavated materials n.exc 50 m and depositing where directed at leveln.exc. 1.50 m above the starting point complete all as specified and as directed by Engineer-in-charge

154.73

-

-

... More
Material and labour for PCC (1:4:8) type D2 using 40mm graded stone aggregate as in foundation filling & mass concrete complete all as specified and as directed by Engineer-in-charge.

23.78

-

-

... More
M&L for brickwork with fly ash bricks, old size bricks, straight or curved on plan exc. 6 m mean radius built in cm 1:6 all as specified and directed.

507.06

-

-

... More
M&L for Reinforced Cement Concrete M-25(design mix) (using 20 mm graded crushed stone aggregates) as in beams, cantilever, lintels over 1.5 m,lintel bands etc complete all as specified and as directed.

17.02

-

-

... More
M&L for reinforced cement concrete (design mix) M-25 using 20mm graded stone aggregrate in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. Note : Reinforcement shall be measured and paid seperately.

40.02

-

-

... More
S&F for Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders cut to length, bent to shape required,including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips Note:- Weight of binding wire shall not be considered for measurement and payment purpose.

887.16

-

-

... More
M&L for sand filling in floors or in foundations including watering and consolidation all specified and directed

18.45

-

-

... More
M&L for 75 mm thick PCC (1:4:8) type D2 using 40mm graded stone aggregate as in sub base below floors all specified and directed.

2683.8

-

-

... More
M& L for Formwork to sides and soffits of flat floor or roof beams, beam haunch ings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc.complete all as specified and as directed by Engineer-in-charge

221.75

-

-

... More
Cutting openings, through brick walls for door, window and other openings or enlarging existing openings. converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc.. to store and rubbish not exc. 50m complete all as specified and as directed by Engineer-in-charge

13.58

-

-

... More
Supply and laying/fixing 60mm thick factory made chamfered edge cement concrete paver block/ interlocking tile of M-35 grade, prepolished & preglazed, with approved colour, design & pattern (laid in required colour & pattern as directed) as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed by Engineer-in-Charge.

2610

-

-

... More
Supply and fixing Factory made kerb stone of size as directed with plain fair faces, chamfers, weatherings, slightly rounded or chamfered angles etc made by using PVC / Rubber moulds on Vibrating Table Machine with grey cement and no pigment with PCC M-25, nominal mix, laid and setting in cement mortar (1:3) complete all as specified and as directed.

2.5

-

-

... More
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/ loose soil including cutting of grass, roots, bushes if any and filling of lower portion with soil obtained from cutting and dressing complete all as specified and as directed by Engineer-in-charge.

2610

-

-

... More
Removing excavated material (surplus soil) to a distance exceeding 1.5 Km and not exceeding 5 Km and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and as directed by Engineer-in-charge.

391.5

-

-

... More
E/M Portion

-

-

-

... More
Taking down carefully existing copper/aluminium point wiring (light/fan/sockets/bell/power point) complete with all accessories such as switch with sheet, ceiling rose including rusted/broken concealed conduit, junction and sunken boxes etc and removing dismantled material complete all as specified and as directed by Engineer-in-Charge..

3876

-

-

... More
Taking down MCB with sheet metal enclosure, main switch, DB, etc and making good disturbed surfaces to match with existing surfaces.

91

-

-

... More
Taking down carefully submain wiring/ service connection of any type complete with casing caping / conduit etc complete all as specified and directed.

984

-

-

... More
Material and labour for concealed Point wiring for one light point/fan point /bell point controlled by one switch (using red, black and green colour wires as colour coding) complete with 2.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction box, 2mm thick galvanised steel pressed sunken terminal boxes of suitable size (Min 60mm deep, suitable length) concealed in wall, 3mm thick bakelite plastic laminated sheet top cover for sunken boxes flush to surface for mounting of switches / socket / regulator etc, including provn of 2.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (switches, socket, regulator etc shall be measured and paid separately under appropriate item of BOQ).

1786

-

-

... More
All as per srl item No 125 here in before, but for ceilling/exhaust fan paint controlled by one switch and regulator complete all as specified and as directed.

500

-

-

... More
All as per srl item No 125 here in before, but for 3 pin 5 Amp socket outlet point on the same board with other switch, sockets complete all as specified and as directed.

418

-

-

... More
All as per srl item No 125 here in before, but for one socket out let 5 Amps point controlled by one switch (on independent board and not below the any other switch board) complete all as specified & directed

672

-

-

... More
All as per srl item No 125 here in before, but for one bell/buzzer point contolled by one bell push complete all as specified & directed

82

-

-

... More
Material and labour for concealed Point wiring for one light point controlled by two Nos- two way switch (using red, black and green colour wires as colour coding) complete with 2.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction box, 2mm thick galvanised steel pressed sunken terminal boxes of suitable size (Min 60mm deep, suitable length) concealed in wall, 3mm thick bakelite plastic laminated sheet top cover for sunken boxes flush to surface for mounting of switch, including provn of 2.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (switches,socket etc shall be measured and paid separately under appropriate item of BOQ).

21

-

-

... More
Material and labour for concealed Point wiring for one socket out let 15/16 Amps power point controlled by one switch (on independant board) (using red, black and green colour wires as colour coding) complete with 4.0 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction box, 2mm thick galvanised steel pressed sunken terminal boxes of suitable size (Min 60mm deep, suitable length) concealed in wall, 3mm thick bakelite plastic laminated sheet top cover for sunken boxes flush to surface for mounting of switches / socket, including provn of 4.0 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (switch, socket etc shall be measured and paid separately under appropriate item of BOQ).

418

-

-

... More
Supply and fixing piano type, 230/250 Volts grade on top covers, Modular switch one way 6 A, 1 module complete all as specified and as directed.

3376

-

-

... More
Supply and fixing piano type, 230/250 Volts grade on top covers, Modular switch two way 6 A, 1 module complete all as specified and as directed.

42

-

-

... More
Supply and fixing piano type, 230/250 Volts grade on top covers Modular switch, one way 16 Amp, 1 Module complete all as specified and as directed.

418

-

-

... More
Supply and fixing piano type, 230/250 Volts grade on top covers Modular bell push 6 Amp, 1 Module complete all as specified and as directed.

82

-

-

... More
Supply and fixed modular Socket outlet multipurpose type 2 in 1, 3 Pin 5 Amp, flush type (2 module) complete all as specified and as directed by Engineer-in-charge.

754

-

-

... More
Supply and fixed modular Socket outlet multipurpose type 2 in 1, 3 pin, 15 Amp, flush type (2 module) complete all as specified and as directed by Engineer-in-charge.

418

-

-

... More
M & L for invertor wiring with 2.5 Sqmm Single core(1run) FRLSH PVC insulated unsheathed multistrand copper conductor cable drawn through PVC conduit 20 mm dia (medium quality ISI marked) incl all fittings arrangments ie PVC clamp rawl plug, screw PVC juction box, tee bend etc and including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed by Engineer-in-charge.

580

-

-

... More
Supply and fixing LED tube light fitting polycarbonate housing 1 x 20 Watt, 4 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 volts. (c) Temp operating range : Minus 5°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) LED Driver of the same make as of the luminaire. (h) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (j) Surge protection minimum 2.5 kV. (k) CCT : Minimum 6000K (l) CRI : Minimum 80 (m) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)

754

-

-

... More
Supply and fixing batten holder (ISI marked) polycarbonate cased body (B22 base), top line series, with back plate, 6Amps, complete all as specified and directed by Engineer-in-Charge.

746

-

-

... More
Supply and fixing LED lamp minimum 5 star rated 9W, B-22 base complete all as specified and directed by Engr-in-Charge with following specifications (a) Lumen system efficacy of lamp should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) CRI : Morethan 80

746

-

-

... More
Supply and fixing LED Bulkhead fitting 1 x 10 Watt, complete with Standard LED lighting fixture with extruded polycarbonate housing environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to light fitting, complete fitting with all accessories and following specifications complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 5°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : <15%. (f) IP rating : IP-65. (g) CCT : Minimum 5400K (h) Polycarbonate housing white coloured (j) LED Driver of the same make as of the luminaire. (k) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (l) Surge protection minimum 2.5 kV. (m) CRI : Minimum 80 (n) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)

82

-

-

... More
Supply and fixing Mirror LED light fitting 1 x 10 Watt, durable and weatherproof , with IP 65 protection e environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to light fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 5°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) CRCA pre coated housing with plastic end cap. (h) LED Driver of the same make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection minimum 2.5 kV. (l) CCT : Minimum 6000K (m) CRI : Minimum 80 (n) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)

164

-

-

... More
Supply and fixing ceiling rose surface bakelite two to three terminals/plate 5 amps complete all as specified and directed by Engr-in-Charge.

1418

-

-

... More
Supply and fixing in replacement (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) SPN, 8 Way 240V, suitable for mounting MCB/Isolator, conforming to IS-13032, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-42 protection class, including taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCB’s shall be measured and paid separately under appropriate item of BOQ.

82

-

-

... More
Supply and fixing in replacement (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 250 Amp rated bus bar) VTPN, 4 Way, suitable for mounting MCCB/MCB, conforming to IS-13032, DB shall be semi glosy finished with epoxy polyster based power paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door worth locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with lable marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-42 protection class, including taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCCB/MCB shall be measured and paid separately under appropriate item of BOQ.

9

-

-

... More
Supply and fixing MCB ‘B’ curve suitable for 240 volts AC supply, 06 to 32 Amps, SP with over load and short circuit protection and rupturing capacity not less than 10 KA, fixing in existing DB/panel (new or old) complete all as specified and as directed by Engineer-in-charge

573

-

-

... More
Supply and fixing MCB ‘B’ curve suitable for 240 volts AC supply, 40 Amps, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA, fixing in existing DB/panel (new or old) complete all as specified and as directed by Engineer-in-charge

82

-

-

... More
Material and labour for concealed sub main wiring (using colour coding such as red, black, white, green colour or as directed) with 6 Sqmm single core (03 run i.e 2 runs for main phase and neutral, 01 run for continues as earth wire) FRLSH PVC insulated unsheathed multistrand copper conductor cable drawn through and including PVC conduit 25mm dia (medium quality ISI marked), for independent circuit including all fitting arrangement i.e. PVC clamp, rawl plug, screw, PVC junction box, tee, bend etc. and including cutting of chases in wall and making good disturbed surfaces of walls as per original complete all as specified and as directed. Note :- Three runs of copper conductor cable and one run of PVC conduit including accessories shall be measured and paid as one unit (one RM length) for payment and extra length of cables required for connection to MCBs/DB shall not be measured and the cost for the same shall deemed to be included in the unit rate.

984

-

-

... More
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI earthing wire 4 mm dia by means of GI bolts/nuts/washers and protected by 15 mm bore GI medium grade pipe upto test point or upto main switch board, fixing with 02 Nos nuts and bolts. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50m, Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) including taking out/dismantling old unserviceable earthing system and old material deposited at MES AGE store complete all as specified and as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing wire upto test point or upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.

18

-

-

... More
Supply and fixing single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with and incl one single pole MCB of capacity 20 Amps, 240 volts, AC supply complete all as specified and directed by Engineer-in-Charge.

82

-

-

... More
Supply and fixing in replacement energy efficient LED street light fitting of 35W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street/Roadway luminaire, with driver, including electric connection, fixing the light fitting with new bracket made out of GI tubing light grade 32mm dia, 1.2 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron size 40x3 mm with suitable nuts and bolts for fixing of bracket including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, including taking down old Unserviceable light fitting with old bracket any type complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP66. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the same make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : Morethan 80 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily)

40

-

-

... More
Supply and fixing ventilating Air axial flow Fan of size 300mm sweep, 240 V, 50 Hz single phase, 1200RPM, copper winding, made of sturdy Engineering plastic complete with louvers shutter, including provision of cutting of wall for suitable opening as per fan and making good the disturbed surface as per existing, including electric connection with and including new 1 Sqmm, 2 core flexible copper conductor cable from ceiling rose to fan, complete all as specified and as directed by Engineer-in-charge.

164

-

-

... More
Supply, installing, commissioning and testing of electric water heater (Geyser, vertical type) storage type ABS body of capacity 25 litre with 2kw heating element, BEE approved 5 Star rating, 230 V, single Phase, AC supply, inner tank made out of heavy duty stainless steel sheet (Designed with single weld line, factory tested with hydraulic pressure as per latest IS code) with glass lined coating complete with all accessories such as having indicating light, safety valve, thermostat, NRV, connection piece PVC connection 600mm long heavy duty suitable for Hot and cold water, three core PVC insulated PVC Sheathed copper conductor flexible cable and making connections with and including 15 amp top plug, 04 Nos suitable size mild steel L-Hook fastener with washer for hanging the geyser and making good the disturbed surface complete all as specified and directed by Engr-in-Charge. Note (a) Contractor shall submit original purchase voucher and warranty card as recommended by manufacturer. (b) Serial Number of geyser issued by Engr-In-Charge and GE Office name shall also be written on geyser with red colour permanent marker or paint, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account.

82

-

-

... More
Supply and hanging /fixing ceiling fan 1200 mm sweep AC Supply (Input Voltage Range ; 120 to 280V), BLDC type, 5 star rated, BEE and ISI Marked super enamelled, copper winding of 'B' class insulation, single phase, minimum 26W (± 10%), Temperature rise 40 degree maximum without remote with and including capacitive regulator, 03 No blades, down rod including accessories, white colour, total harmonic less than 10%, 5 speed, hanging in position including making connection with flexible cord three core twisted copper conductor of suitable size from ceiling rose to fan including taking down old ceiling fan complete all as specified and as directed by Engineer-in-charge. Note :- (i) Serial Number as issued by Engr-In-Charge of celing fan and GE Office name shall also be written on fan with red colour permanent marker and fixing of regulator on switch board, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account (ii) Old ceiling fan shall be deposited in AGE E/M store yard.

246

-

-

... More
Supply and fixing exhaust fan (heavy duty) steel body, AC single Phase 230V, 50 Cycle per second, size 300mm sweep with blades and frame including self closing GI louvers off mode protection against birds etc mounted in suitable opening arrangement. including electric connection with and including new 1 Sqmm, 2 core flexible copper conductor cable from ceiling rose to fan, (not exceeding 0.5 mtr long), and hanging on wall with 4 Nos steel fastners 10mm dia 100mm long and making good the disturbed surface complete all as specified and as directed by Engineer-in-charge. Note :- Serial Number of exhaust fan issued by Engr-In-Charge and GE Office name shall also be written on fan with red colour permanent marker.

82

-

-

... More
Supply and laying DWC pipe size 40 mm dia including fitting accessories for protection of cable ISI marked conforming IS 16205 complete all as specified and directed by Engr-in-Charge

360

-

-

... More
Supply and laying or fixing or laid in trenches / ducts / through pipes / in floors / under roads / under hard standing /along poles and testing, Cross linked Polyethylene (XLPE) LT Cable, XLPE Insulated, PVC inner sheathed, bedded, galvanised steel strip or wire armoured cable (heavy duty) 1100 volt grade with stranded aluminium conductor having cross sectional area 25 Sqmm 4 core conforming to IS-7098 (Part-I)-1988 with upto date amendments, including taking out old unserviceable cable any size complete all as specified and as directed. Note :- (i) Excavation, earth work, sand cushioning, brick protection, boring/cutting of road and pipe shall be measured & paid separately under appropriate item of this Schedule.)

400

-

-

... More
M&L for Boring hole/Excavation by trenchless technology for boring of holes under road, pavement, hardstanding using trenchless boring machine or by means of manual manpower suitable for inserting GI pipe including removal of surplus soil and making good disturbed surface complete all as specified and as directed. NOTE:- Pipe for inserting as required shall be measured and paid for separately.

45

-

-

... More
Supply and fixing GI tubing light grade of size 40 mm bore, ISI marked, fixed along poles/walls or laid in trenches, under road for cable protection including fittings (elbow, tee, socket etc) complete all as specified and as directed. (Note:- Excavation and earthwork and MS clamp as required shall be measured and paid separately under respective item of Sch.)

35

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.