Industries And Commerce Department Tender
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 24,000Document Cost
₹ 5,900Tender Fee
₹ 1,424
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_IC_131002_1Tender No
PSIEC/StreetLight/BatalaTender Authority
Industries And Commerce Department ViewPurchaser Address
-Website
http://eproc.punjab.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
XLPE INSULATED UN-ARMOURED CABLES (LOOSE):
-
-
-
... More
Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-
-
-
-
... More
Overall size 16sq.mm (4Core) Un-armoured (Loose)
2360
131
310788.4
... More
G.I. EARTHING:
-
-
-
... More
Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) with G.I. reducing socket including erection of the same, 4.50 metre (14.76 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 8 metre in length (including boring & refilling)
-
-
-
... More
Earthing with 7/12 S.W.G. (7/2.80mm dia.) G.I. rope in 20mm dia G.I. pipe with G.I. reducing socket 50mm x 20mm (upto 8Metre in length)
2
3734
7469.32
... More
GALVANIZED IRON PIPES AND G.I. EARTHING:
-
-
-
... More
Earthing earth rod 20 mm dia for providing earth connections upto line earth with G.I. Wire 8 S.W.G. (4mm dia.). The rod shall be tapered at one end and flatted on other end. The hole size 10mm dia shall be drilled on the flatened side for facilitating connection with G.I. wire and thimble etc. The rod shall be erected in ground upto complete length vertically:-
-
-
-
... More
G.I Earth rod 20 mm dia., 3 mtr. Long
10
1274
12747.4
... More
MINIATURE CIRCUIT BREAKERS:
-
-
-
... More
Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-
-
-
-
... More
MCB Single Pole 6-32amp. (10kA, Curve-C)
60
190
11434.8
... More
SHEET METAL BUS BAR CHAMBERS (COPPER STRIPS):
-
-
-
... More
Supply and erection of sheet metal bus bar chamber (factory fabricated) duly powder coated on existing surface with required 4Nos. of tin plated copper bus bar strips of suitable length and cross-sectional area mounted on DMC/ SMC moulds at sufficient distance, enclosure made of M.S. sheet 1.6mm thick with hinged cover and lock, fitted with dust excluding gaskets and secured with sufficient no. of cadmium plated iron screws and of given overall dimensions and to be fixed with G.I. bolts and nuts/ rag bolts and nuts etc. complete with all accessories including connections with suitable size of thimbles, bonding to the existing earth and painting etc. as desired by the Engineer-in-charge at site:-
-
-
-
... More
Bus Bar Chamber 63amp., 415volts Overall Dimensions (300mm x 345mm x 120mm) nominal
1
5025
5025.2
... More
MCCB’s MOULDED CASE CIRCUIT BREAKERS
-
-
-
... More
Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:-
-
-
-
... More
MCCB Four Pole 63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting
2
6626
13253.46
... More
GALVANIZED STEEL OCTAGONAL POLES FOR WIND VELOCITY OF 169 Km/ HOUR:
-
-
-
... More
Supply and erection of Galvanized Steel Octagonal Pole (Sheet thickness 3mm) designed to withstand wind speed 169km/ hour of suitable length (Raw material confiming to IS-5986 (FE-510), BSEN-10025S- 355J or ASTM-572A (GR-50)) and thickness of galvanization (70mm thick) conforming to IS:2629/ IS:2633/ IS:4759, BSEN-ISO-1461- 1991 OR ASTM-A123/A123M-02. The pole shall be in single piece hot dip galvanized and shall be tapered towards the top. The bottom section shall have openable slot with exterior surface door & shall have suitable locking arrangement for housing three phase 4wire cable connection, bakelite sheet, MCB, loop in and out arrangement for incoming/ outgoing cables. There shall be suitable arrangement for earthing. Rigid Base plate of suitable size and thickness shall be welded inside and outside at the bottom of pole with provision for fixing 4 foundation bolts. The octagonal pole shall be bolted on a pre- cast foundation with a set of four foundation bolts for greater rigidity. The foundation shall be erected over cement concrete M20 with steel of given size as per design of original pole manufacturer to fixed up to a required planting depth below ground level as required:-
-
-
-
... More
Galvanized Octagonal Pole Overall Length 6 metre (Sheet thickness 3mm), Top dia.(A/F) 70mm and bottom dia. (A/F) 130mm, Foundation size below G/L 550mm x 550mm x 1200mm, 4Nos. Foundation Bolts size 20mm dia., Length≥600mm with Base Plate Dimensions 220mm x 220mm x 12mm Thick
10
21228
212280.3
... More
GALVANIZED OCTAGONAL POLE BRACKETS:
-
-
-
... More
SINGLE/ DOUBLE ARM BRACKETS:
-
-
-
... More
Supply and erection of bracket for galvanized octagonal pole, the bracket should be fixed on the top of the pole having top outer dia. 70mm to 90mm (A/F) complete in all respect as approved by the Engineer-in-charge at site:-
-
-
-
... More
Single arm bracket 1 metre long for galvanized octagonal pole
10
2040
20406.3
... More
Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:-
-
-
-
... More
Double Walled Corrugated HDPE Pipe 50/38mm (Outer/ Inner dia.)
2050
133
274269.5
... More
SHEET METAL CUBICAL PEDESTAL, TOWER STRUCTURES, HT & LT LINE ITEMS, MS CHANNELS, BRASS GLANDS, ALUMINIUM & COPPER THIMBLES:
-
-
-
... More
CUBICAL PEDESTAL:
-
-
-
... More
Supply and erection of Sheet metal cubical pedestal made from 50mmx50mmx6mm thick MS angle iron frame with 5 sides welded & covered with MS sheet 2mm thick & front side hinged with 4" hinges & locking system with single/ double door openable placed on MS strip of size 12.5mm x 2.5mm thick welded with MS sheet, 4Nos. legs of 50mmx50mmx6mm thick MS angle iron each of 600mm long with MS sheet 100mmx100mmx6mm thick at the bottom end of the legs. Front door welded x-sectionally with MS flat 25mmx5mm. The front side with MS sheet each 75mm wide & a bend of 75mm width outwards & inwards on all sides with tappered top 200mm high and pedestal with 4 Nos. supporting members each of MS flat 50mmx6mm thick according to cubical size duly welded & complete pedestal to be painted with 1 coat of red oxide & 2 coats of paint & bonding to the existing earth. The Pedestal platform should be filled with 1:2:4 cement concrete mixture and erected 150mm high from the top of the cement concrete platform. The job is to be completed as approved by Engineer-in-charge:-
-
-
-
... More
Cubical Size 900mm high, 600mm wide and 350mm deep with platform dimensions 700mm x 450mm x 450mm
1
12641
12641.37
... More
Cubical Size 1200mm high, 900mm wide and 350mm deep with platform dimensions 1000mm x 450mm x 450mm
1
17953
17953.96
... More
Trench less hand Horizontal bore for laying of cable below cement concrete areas in the focal point upto a size of 160 mm dia. Complete as per direction of the engineer in charge.
60
816
48987.6
... More
Supply, erection, testing and commissioning of 45 Watt L.E.D street light fitting of approved makes as per following specification. As per Advisor(Technical), Govt. of Punjab vide letter no.1422 dated 06.05.2021 including the cost of petty material i.e. nut & bolt, reducers as per fitting complete in all respect entire satisfaction of engineer-in-charge.
60
4200
252000
... More
ELECTRICAL PARAMETERS:
-
-
-
... More
Input Operating Voltage :140 to 270 Volts AC
-
-
-
... More
testing voltage range at site/manufacture premises : 70 to330 volts AC Cut off/withstand +10% AC
-
-
-
... More
Input AC Frequency :AC 50 Hz + 3%
-
-
-
... More
Efficiency of driver :More than 85%, the control gear should be complying with IEC 61347 -2-13, IEC 62384 & IEC 62031 as per requirement. The driver should comply with CISPR-15 for limit and methods of measurement of ratio disturbance characteristic. Current waveform should meet 61000-3-2 the driver should be constant current driver.
-
-
-
... More
Driver Type:BIS certified potted single driver with screen or laser printed logo upto 150 W Street light, flood light and high/medium/low bay luminaires
-
-
-
... More
Driver Type :BIS certified potted double driver with screen or laser printed logo upto 150 W Street light, flood light and high/medium/high bay luminaires
-
-
-
... More
THD (Total Harmonic Distortion) : 10%
-
-
-
... More
LED Driver current(for each driver with tolerance value) : Max 750 + 5% Ma
-
-
-
... More
Efficacy of LED fixture :Minimum 120 lumens per watt
-
-
-
... More
Efficacy of LED chip/source :Minimum 140 lumens per watt
-
-
-
... More
Working humidity :10% to 90% RH
-
-
-
... More
Surge Protection : 4KV SPD within driver and 10 KV external SPD within driver compartment of fixture for luminaiers 45 Watt
-
-
-
... More
4KV SPD within driver and 10 KV external SPD outside driver compartment of fixture for luminaiers 45 Watt
-
-
-
... More
OPTICAL PARAMETERS:
-
-
-
... More
LED chip/source Make : NICHIA/Philips Lumiled/Cree/Osram/Seoul
-
-
-
... More
LED chip/source Life (TM-21 report):Above 50000 operating hours at 70% lumens
-
-
-
... More
CRI (Color Rendering Index) : Minimum 70
-
-
-
... More
Wattage of LED chip/source:Each LED shall be of high power LED with wattage 1 watt to 5 watt
-
-
-
... More
Lenses:Mandatory secondary Lenses.
-
-
-
... More
THERMAL PARAMETERS:
-
-
-
... More
Working Temperature : 0 degree C to 50 degree C
-
-
-
... More
Color Temperature : Nominal CCT (ANSI C78.377A) CCT CCT RANGE (a) 5700k 5665 + 355
-
-
-
... More
Heat Sink : Pressure Diecast or Extruded Aluminium
-
-
-
... More
Junction Temperature : 100 degree C
-
-
-
... More
GENERAL PARAMETERS:
-
-
-
... More
Body of fitting :ADC 12 or LM-6 Grade single Piece Pressure diecast Aluminium housing with separate driver compartment (with IP 66 Protection) with company logo engraved/embossed on the housing
-
-
-
... More
Ingres Protection:IP66 as per IEC 60529:2001 or IS 10322 with test certificate
-
-
-
... More
Impact code:Min IK07
-
-
-
... More
Optical Cover : (i) Toughened glass/ Polycarbonate cover with prescribed thickness according to type of usage for fitting with rating 30W (ii) Only toughened glass with prescribed thickness according to type of usage for fitting with rating 30 W
-
-
-
... More
LM79 Report (Wattage, Lumens output, Efficancy, CRI, CCT) :Duly supported with relevant LM 79 reports not more than two years old from NABL/UL accredited laboratory.
-
-
-
... More
LM-80/TM-21 Report :Depreciation life of LED chip/source should be verified by LED chip/source manufacturer as mentioned in Para-B(1)
-
-
-
... More
Electrical Protection: The fitting should have a low/ high voltage, reverse polarity, overload and short circuit protection inbuilt in the fixture itself and it should sustain at 440V upto four hours as per IS standards.
-
-
-
... More
Authenticity of Fixture : The contractor should submit the certificate from the OEM's of Luminaire regarding the authenticity, specifications and five years warranty of fittings duly signed by the rank of Branch Manager (minimum) as per Annexure –A attached.
-
-
-
... More
MARKING :
-
-
-
... More
Manufactures name/Year of manufacture : Marking Sticker on the fitting
-
-
-
... More
Rated voltage (marked “V” or volts) : Marking Sticker on the fitting
-
-
-
... More
Rated Wattage (marked “W” or watt) : Marking Sticker on the fitting
-
-
-
... More
Batch No/Serial No. : Marking Sticker on the fitting
-
-
-
... More
BIS Marking (R. N0.) : Marking Sticker on the fitting
-
-
-
... More
NOTES
-
-
-
... More
Make of LED chip/ source used in luminaries should be mentioned in the Technical Data Sheet.(TDS)
-
-
-
... More
Dimentions of heat sink and luminaries should be according to the wattage of luminaries.
-
-
-
... More
All the luminaries should be bottom opening type as per latest IP standards and requirement by User Department and type of usage.
-
-
-
... More
There should be proper spacing between drivers, SPD, Connectors, Wiring, etc., within driver compartment for easy maintenance point of view in future.
-
-
-
... More
Less credit for old material.
1
20000
-20000
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%