Food Corporation Of India Tender

... More
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Food Corporation Of India - FCI Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date16 Feb 2023
Closing Date4 Mar 2023
Tender Amount₹ 40,48,593 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
4 X 1.5 sq mm (DSR 2022 Item no.1.17.4)

806

96720

120

... More
5 X 1.5 sq mm (DSR 2022 Item no.1.17.5)

165

25575

155

... More
6 X 1.5 sq mm (DSR 2022 Item no.1.17.6)

180

32580

181

... More
7 X 1.5 sq mm (DSR 2022 Item no.1.17.7)

180

38880

216

... More
8 X 1.5 sq mm (DSR 2022 Item no.1.17.8)

180

43380

241

... More
9 x 1.5 sq mm (DSR 2022 Item no.1.17.9)

189

53865

285

... More
3 X 2.5 sq mm (DSR 2022 Item no. 1.17.12)

380

52060

137

... More
6 X 2.5 sq mm (DSR 2022 Item no.1.17.15)

318

84270

265

... More
3 X 4 sq mm (DSR 2022 Item no.1.17.21)

455

93730

206

... More
Sub Head -III (Switchgear and earthing) Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 75 mm X 75 mm X 60 mm deep (DSR 2022 - Item no.1.22.1)

48

8544

178

... More
150 mm X 75 mm X 60 mm deep (DSR 2022 - Item no.1.22.3)

48

10368

216

... More
Sub Head -III (Switchgear and earthing) Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 5/6 A switch (DSR 2022 - Item no.1.23.1)

219

11388

52

... More
Sub Head -III (Switchgear and earthing) Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.(DSR 2022 - Item no.1.33)

180

15660

87

... More
Sub Head -III (Switchgear and earthing) Supplying and fixing of horizontal type three pole and nuetral sheet steel MCB distribution board, 415Volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, inter connections, powder painted including earthing etc., as required (but without MCB/RCCB/Isolator ) 4 way (4 + 12), Double door (DSR 2022 Item 2.4.1)

4

16364

4091

... More
Sub Head -III (Switchgear and earthing) Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way , Double door (DSR 2022 Item 2.3.2)

12

30876

2573

... More
6 way , Double door (DSR 2022 Item 2.3.1)

1

2206

2206

... More
Sub Head -III (Switchgear and earthing) Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB omplete with connections, testing and commissioning etc. as required. Single pole (DSR 2022 Item no.2.10.1)

69

17664

256

... More
Single pole and neutral (DSR 2022 Item no.2.10.2)

14

8386

599

... More
Triple pole and neutral (DSR 2022 Item no.2.10.5)

4

4912

1228

... More
Sub Head -III (Switchgear and earthing) Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete with connections, testing and commisssioning etc. as required. 25 A DSR 2022 item no 2.14.1

12

24336

2028

... More
Sub Head -III (Switchgear and earthing) Dismantling the existing switch cover/plate alongwith damaged tumbler type switches and damaged existing metal box as required.

48

5520

115

... More
Sub Head -III (Switchgear and earthing) Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. (DSR 2022 - Item no.2.18)

12

19452

1621

... More
Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. (DSR 2022-Item No. 2.20)

3

12321

4107

... More
Sub Head -III (Switchgear and earthing) Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required..(DSR 2022 Item no.5.4)

10

74720

7472

... More
Sub Head -III (Switchgear and earthing) Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from FRLS om earth electrode including connection with G.I. thimble excavation and re-filling as required. (DSR 2022 Item no.5.12)

70

20090

287

... More
Sub Head -III (Switchgear and earthing) Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. (DSR 2022 Item no.5.16)

462

32340

70

... More
Sub Head -III (Switchgear and earthing) Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.(DSR 2022 Item no.5.6)

1

13838

13838

... More
Sub Head -III (Switchgear and earthing) Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.(DSR 2022 Item no.5.10)

5

7755

1551

... More
Sub Head -III (Switchgear and earthing) Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. (DSR 2022 Item no.5.14)

6

6972

1162

... More
Sub Head -IV ( Fittings ) Supplying, installation, testing and commissioning of 1x 20W Retrofit type Photon Ultra bright LED polycarbonate tubelight along with Industrial Box type Luminaire batten suitable for single T8 LED Tube on wall/truss for fixing LED tube including connection, testing as required.

148

239168

1616

... More
Sub Head -IV ( Fittings ) Supplying, installation, testing and commissioning of 2x 20W Retrofit type Photon Ultra bright LED polycarbonate tubelight along with Industrial Box type Luminaire batten suitable for Twin T8 LED Tube on wall/truss for fixing LED tube including connection, testing as required.

46

111090

2415

... More
Sub Head -IV ( Fittings ) Supplying, installation, testing and commissioning of 20W LED tube alongwith Industrial Batten of Environmental friendly, long life, corrosion resistant, impact proof, surface mounting IP65 luminaire with PC housing & opal finish cover suitable for LED tubes and fixing on wall/truss by using necessary clamps and also dismantling the existing fitting.

46

142922

3107

... More
Sub Head -IV ( Fittings ) Supplying, installation, Testing and commissioning of 45 watt LED 5700K type LED streetlight made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection with impact resisitance of IK07 and fixing on truss /wall/ pole with suitable clamps and nut bolts including giving connection testing etc., at site of work as required.

54

349596

6474

... More
Sub Head -IV ( Fittings ) Supplying, installation, testing and commissioning of LED flood light fitting 120 watt made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP 66 Protection.

12

151536

12628

... More
Sub Head -IV ( Fittings ) Supplying, installation, Testing and commissioning of 70 watt LED Well Glass fitting of Environmental friendly, IP protection energy saving long life corrosion resistant, vertical/horizontal surface mounting pressure die-cast aluminium well glass luminaires with high power LED as light source and fixing on truss /wall/ pole with suitable clamps and nut bolts including giving connection testing etc., at site of work as required.

39

391794

10046

... More
Sub Head -IV ( Fittings ) Supplying, installation, Testing and commissioning of 35 watt LED 5700K Post top lantern type IP65 with high power LEDs as light source and fixing on pole with suitable clamps and nut bolts including giving connection testing etc., at site of work as required.

4

47956

11989

... More
Sub Head -IV ( Fittings ) Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. DSR 2022 item no. 19.1

20

54600

2730

... More
Sub Head V - Underground Cabling Works Supply of PVC insulated and PVC sheathed XPLE power cable of 1.1 KV grade armoured UG aluminium conductor cable conforming to IS 7098 part 1 with up-to-date amendment of the following size as required. 3 x 16 sq.mm

1585

420025

265

... More
4 x 16 sq.mm

430

140610

327

... More
4 × 25 sq.mm

140

59780

427

... More
Sub Head V - Underground Cabling Works Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle) (DSR 2022 -Item no.7.7.1)

1211

66605

55

... More
Sub Head V - Underground Cabling Works Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq mm DSR 2022 Item no 7.1.1

153

59211

387

... More
Sub Head V - Underground Cabling Works Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq mm DSR 2022 Item no 7.2.1

148

39812

269

... More
Sub Head V - Underground Cabling Works Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.up to 35 sq.mm. Up to 35 Sq mm (DSR 2022 -Item no.7.5.1)

138

5106

37

... More
Sub Head V - Underground Cabling Works Providing, laying and fixing following dia G. I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and refilling etc as required. 100 mm dia (DSR item no 14.13.3)

51

92106

1806

... More
Sub Head V - Underground Cabling Works Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 meter length along the pole for protection of under ground cable as required (DSR 2022 -Item no.12.37)

18

46152

2564

... More
Sub Head V - Underground Cabling Works Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2 x 16 sq mm (DSR 2022 item no 9.1.3) (22 mm)

2

512

256

... More
3 x 16 sq mm (25 mm) (DSR 2022 item no 9.1.8)

135

36450

270

... More
4 X 16 sq. mm (28mm) (DSR 2022 -Item no.9.1.33)

7

2163

309

... More
4 X 25 sq. mm (28 mm) (DSR 2022 -Item no.9.1.34)

2

630

315

... More
Sub Head V - Underground Cabling Works Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. DSR 2022 Item no 7.10

16

8128

508

... More
Sub Head V - Underground Cabling Works Supplying and fixing street light loop in loop out boxes with PVC Box of size 8"x6"x4" with 1 No. 6A SP MCB, 2/4 way strip connector i/c testing as reqd.

70

136500

1950

... More
Sub Head V - Underground Cabling Works Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish Paint etc. as required. DSR 2022 item no 12.34

30

44310

1477

... More
Sub Head V - Underground Cabling Works Supply and fixing 5.0 mtrs of 40 mm GI pipe (medium grade) with necessary clamping at both the ends of the pipe as required.

39

151008

3872

... More
Sub Head VI - MV Panel Supply and fixing of 4 pole 100A 25kA MCCB in the Main panel by replacing the existing damaged unit as required.

2

12746

6373

... More
Sub Head VI - MV Panel Supply and fixing of 4 pole 32 A 25kA MCCB in the Main panel by replacing the existing damaged unit as required.

4

24072

6018

... More
Sub Head VI - MV Panel Supply and fixing of 4 pole 63A 25kA MCCB in the Main panel by replacing the existing damaged unit as required.

5

30215

6043

... More
Sub Head VI - MV Panel Supplying and installation of 400x400x250 mm 16SWG MS sheet fabricated loop in loop out box with 4 strip of 100 A aluminium bus bars to the required location with proper electrical connections.

1

4185

4185

... More
Sub Head VII - Miscellaneous works Removing the existing aluminium wire from conduit, main board, sub-main boards, switch boards, tube light fittings etc., and shifting the same to stores etc., as required.( for shed no 1,2,3&4 )

1

12198

12198

... More
Sub Head VII - Miscellaneous works Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. DSR 2022 Item no. 2.21

2

538

269

... More
Sub Head VIII - Credit Items Less credit for dismantaled old damaged metal scrap including transportation and disposal of the same from the site.

170

-3400

20

... More
Sub Head VIII - Credit Items Less credit for dismantled old damaged PVC insulated Al wire including transportation and disposal of the same from the site.

85

-3400

40

... More
Sub Head VIII - Credit Items Less credit for dismantaled old damaged Single pole MCB 6 to 32 Amp.

40

-200

5

... More
Sub Head VIII - Credit Items Less credit for dismantaled old damaged Single SPN 6 to 40 Amp.

20

-200

10

... More
Sub Head VIII - Credit Items Less credit for dismantaled old damaged 5/6Amp piano/round type switch.

125

-125

1

... More
Sub Head VIII - Credit Items Less credit for dismantaled old damaged 70/150W street light HPSV fitting.

30

-11340

378

... More
Sub Head VIII - Credit Items Less credit for dismantaled old damaged 70 w low bay HPSV/MH fitting.

28

-10584

378

... More
Sub Head VIII - Credit Items Less credit for dismantaled old damaged 40W Flourescent fitting.

135

-5535

41

... More
Sub Head VIII - Credit Items Less credit for dismantaled old damaged cable termination M.S box and scrap.

38

-1064

28



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.