Food Corporation Of India Tender

If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Food Corporation Of India - FCI Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date16 Feb 2023
Closing Date4 Mar 2023
Tender Amount₹ 35,69,684 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
4 X 1.5 sq mm (DSR 2022 Item no.1.17.4)

750

90000

120

... More
5 X 1.5 sq mm (DSR 2022 Item no.1.17.5)

119

18445

155

... More
6 X 1.5 sq mm (DSR 2022 Item no.1.17.6)

138

24978

181

... More
7 X 1.5 sq mm (DSR 2022 Item no.1.17.7)

82

17712

216

... More
8 X 1.5 sq mm (DSR 2022 Item no.1.17.8)

90

21690

241

... More
9 x 1.5 sq mm (DSR 2022 Item no.1.17.9)

94

26790

285

... More
3 X 2.5 sq mm (DSR 2022 Item no. 1.17.12)

515

70555

137

... More
6 X 2.5 sq mm (DSR 2022 Item no.1.17.15)

320

84800

265

... More
3 X 4 sq mm (DSR 2022 Item no.1.17.21)

420

86520

206

... More
Sub Head -III (Switchgear and earthing) Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 5/6 A switch (DSR 2022 - Item no.1.23.1)

225

11700

52

... More
Sub Head -III (Switchgear and earthing) Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.(DSR 2022 - Item no.1.33)

134

11658

87

... More
Sub Head -III (Switchgear and earthing) Supplying and fixing of horizontal type three pole and nuetral sheet steel MCB distribution board, 415Volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, inter connections, powder painted including earthing etc., as required (but without MCB/RCCB/Isolator ) 4 way (4 + 12), Double door (DSR 2022 Item 2.4.1)

5

20455

4091

... More
Sub Head -III (Switchgear and earthing) Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way , Double door (DSR 2018 Item 2.3.2)

12

30876

2573

... More
Sub Head -III (Switchgear and earthing) Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB omplete with connections, testing and commissioning etc. as required. Single pole (DSR 2022 Item no.2.10.1)

56

14336

256

... More
Single pole and neutral (DSR 2022 Item no.2.10.2)

14

8386

599

... More
Triple pole and neutral (DSR 2022 Item no.2.10.5)

5

6140

1228

... More
Sub Head -III (Switchgear and earthing) Supplying and fixing following rating, double pole, (single phaseand neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 A (DSR-22/2.14.1)

10

20280

2028

... More
Sub Head -III (Switchgear and earthing) Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. (DSR 2022 Item no.2.11)

4

52

13

... More
Sub Head -III (Switchgear and earthing) Dismantling the existing switch cover/plate alongwith damaged tumbler type switches and Providing and fixing of phenolic laminated sheet suitable for existing metal box including switch cutting extra as required.

80

17120

214

... More
Sub Head -III (Switchgear and earthing) Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. (DSR 2022 - Item no.2.18)

13

21073

1621

... More
Sub Head -III (Switchgear and earthing) Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. (DSR 2022 Item no.2.20)

4

16428

4107

... More
Sub Head -III (Switchgear and earthing) Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required..(DSR 2022 Item no.5.4)

13

97136

7472

... More
Sub Head -III (Switchgear and earthing) Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.(DSR 2022 Item no.5.6)

1

13838

13838

... More
Sub Head -III (Switchgear and earthing) Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.(DSR 2022 Item no.5.10)

5

7755

1551

... More
Sub Head -III (Switchgear and earthing) Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from FRLSom earth electrode including connection with G.I. thimble excavation and re-filling as required. (DSR 2022 Item no.5.12)

65

18655

287

... More
Sub Head -III (Switchgear and earthing) Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.(DSR 2022 Item no.5.14)

6

6972

1162

... More
Sub Head -III (Switchgear and earthing) Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. (DSR 2022 Item no.5.16)

415

29050

70

... More
Sub Head -IV ( Fittings ) Supplying, installation, testing and commissioning of 1x 20W Retrofit type Photon Ultra bright LED polycarbonate tubelight along with Industrial Box type Luminaire batten suitable for single T8 LED Tube on wall/truss for fixing LED tube including connection, testing as required.

114

184224

1616

... More
Sub Head -IV ( Fittings ) Supplying, installation, testing and commissioning of 2 x 20W Retrofit type Photon Ultra bright LED polycarbonate tubelight along with Industrial Box type Luminaire batten suitable for Twin T8 LED Tube on wall/truss for fixing LED tube including connection, testing as required.

40

96600

2415

... More
Sub Head -IV ( Fittings ) Supplying, installation, testing and commissioning of 20W LED tube alongwith Industrial Batten of Environmental friendly, long life, corrosion resistant, impact proof, surface mounting IP66 luminaire with PC housing & opal finish cover suitable for LED tubes and fixing on wall/truss by using necessary clamps and also dismantling the existing fitting.

40

124280

3107

... More
Sub Head -IV ( Fittings ) Supplying, installation, Testing and commissioning of 45 watt LED 5700K type LED streetlight made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection with impact resisitance of IK07 and fixing on truss /wall/ pole with suitable clamps and nut bolts including giving connection testing etc., at site of work as required.

55

356070

6474

... More
Sub Head -IV ( Fittings ) Supplying, installation, Testing and commissioning of 70 watt LED LED Well Glass fitting of Environmental friendly, energy saving long life corrosion resistant, vertical/horizontal surface mounting pressure die-cast aluminium well glass luminaires with high power LED as light source and fixing on truss /wall/ pole with suitable clamps and nut bolts including giving connection testing etc., at site of work as required.

51

512346

10046

... More
Sub Head -IV ( Fittings ) Supplying, installation, Testing and commissioning of 35 watt LED 5700K Post top lantern type - IP65 with high power LEDs as light source and fixing on pole with suitable clamps and nut bolts including giving connection testing etc., at site of work as required.

2

23978

11989

... More
Sub Head -IV ( Fittings ) Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. (DSR 2022 Item no.19.1)

7

19110

2730

... More
Sub Head VI - Cabling Works Supply of PVC insulated and PVC sheathed XPLE power cable of 1.1 KV grade armoured UG aluminium conductor cable conforming to IS 7098 part 1 with up-to-date amendment of the following size as required. 3 x 10 sq.mm

1220

312320

256

... More
4 × 16 sq.mm

260

85020

327

... More
4 x 25 sq.mm

215

91805

427

... More
Sub Head VI - Cabling Works Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc. as required 100 mm dia (DSR 2022 Item no.14.13.3)

45

81270

1806

... More
Sub Head VI - Cabling Works Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 X 10 sq. mm (22mm) (DSR 2022 - Item no. 9.1.7)

80

20560

257

... More
4 X 16 sq. mm (28mm) (DSR 2022 -Item no.9.1.33)

8

2472

309

... More
4 X 25 sq. mm (28mm) (DSR 2022 -Item no.9.1.34)

4

1260

315

... More
Sub Head VI - Cabling Works Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. Up to 35 Sq mm (DSR 2022 -Item no.7.3.1)

79

15800

200

... More
Sub Head VI - Cabling Works Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.up to 35 sq.mm. Up to 35 Sq mm (DSR 2022 -Item no.7.5.1)

72

2664

37

... More
Sub Head VI - Cabling Works Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. Up to 35 Sq mm (DSR 2022 -Item no.7.4.1)

125

15750

126

... More
Sub Head VI - Cabling Works Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle) (DSR 2022 -Item no.7.7.1)

1347

74085

55

... More
Sub Head VI - Cabling Works Supplying and fixing street light loop in loop out boxes with PVC outdoor weatherproof Box of size 8"x6"x4" with 1 No. 6A SP MCB, 2/4 way strip connector i/c testing as reqd.

57

111150

1950

... More
Sub Head VI - Cabling Works Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 meter length along the pole for protection of under ground cable as required (DSR 2022 -Item no.12.37)

9

23076

2564

... More
Sub Head VI - Cabling Works Supply and installation of 400x400x250 mm 16SWG MS sheet fabricated loop in loop out box with 4 strip of 100 A aluminium bus bar to the required location with proper electrical connections.

2

8370

4185

... More
Sub Head VI - Cabling Works S/F of 200 Amp Kit Kat fuse complete set for main board in switch room.

1

5311

5311

... More
Sub Head VI - Cabling Works Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 200 A,36KA,FPMCCB (DSR 2022 -Item no. 2.2.15)

1

15206

15206

... More
Sub Head VI - Cabling Works Supply and fixing 5.0 mtrs of 40 mm GI pipe (medium grade) on truss for light fixtures with necessary clamping at both the ends of the pipe as required.

51

197472

3872

... More
Sub Head VI - Cabling Works Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish Paint etc. as required. (DSR 2022 item no 12.34)

18

26586

1477

... More
Sub Head VI - Miscellaneous works Removing the existing aluminium wire from conduit, main board, sub-main boards, switch boards, tube light fittings etc., and shifting the same to stores etc., as required.( for shed no 1, 2, 3 and mini shed)

1

10160

10160

... More
Sub Head VI - Miscellaneous works Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. DSR 2022 Item no. 2.21

1

269

269

... More
Sub Head VII - Credit Items Less credit for dismantaled old damaged metal scrap

300

-6000

20

... More
Sub Head VII - Credit Items Less credit for dismantled old damaged PVC insulated Al wire

230

-9200

40

... More
Sub Head VII - Credit Items Less credit for dismantaled old damaged Single pole MCB 6 to 32 Amp

40

-200

5

... More
Sub Head VII - Credit Items Less credit for dismantaled old damaged Single SPN 6 to 40 Amp

22

-220

10

... More
Sub Head VII - Credit Items Less credit for dismantaled old damaged 5/6Amp piano/round type switch

120

-120

1

... More
Sub Head VII - Credit Items Less credit for dismantaled old damaged 70/150W street light HPSV fitting

65

-24570

378

... More
Sub Head VII - Credit Items Less credit for dismantaled old damaged 70 low bay HPSV/MH fitting

25

-9450

378

... More
Sub Head VII - Credit Items Less credit for dismantaled old damaged 40W Flourescent fitting

100

-4100

41



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.