Department Of Electronics And Information Technology Tender
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Department Of Electronics And Information Technology Tender
Electrical Goods and Equipments
Electrical and Electronics
GEM
Opening Date4 Nov 2024
Closing Soon25 Nov 2024
Tender Amount₹ 41,55,000
Costs
EMD
₹ 82,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
GEM/2024/B/5538758Tender No
GEM/2024/B/5538758Tender Authority
Department Of Electronics And Information Technology ViewPurchaser Address
-Website
http://bidplus.gem.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
scope_and_specs_2024-10-23-17-10-17_ce06e40e56ad4212ad4c8cdaa132af41.pdf
boq_item_sample_file_-8_2024-10-23-17-10-17_53ac11985ea769ec2f7ba4c946826abc.csv
BOQ Items
Installation, testing and commissioning of IEC61439 compliant , Installation, testing and commissioning of IEC61439 compliant, flo or mounted new MCC Panel 2 detailed guideline as per enclosed specifications.
1
-
-
Supply of 3 Phase 415V MCC Panel 3, IEC61439 compliant , Supply of 3 Phase 415V MCC Panel 3, IEC61439 compliant, flo or mounted detailed as per enclosed specifications and SLD.
Make ABB or Siemens or Schneider or Legrand or Land T or Rockwell Automation or its auth or ized TTA IEC61439 vend or s as per enclosed approved vend or list.
1
-
-
Installation, testing and commissioning of IEC61439 compliant , Installation, testing and commissioning of IEC61439 compliant, flo or mounted new MCC Panel detailed guideline as per enclosed specifications.
1
-
-
Supply of 3C x 25 Sq. mm, Stranded Copper Conduct , Supply of 3C x 25 Sq. mm, Stranded Copper Conduct or , XLPE insulated, extruded inner PVC sheet, flat strip or wire armoured and overall FRLS PVC outer sheathed 1.1 KV grade cable, as per IS 7098 Part I with latest amendment as required.
Note Party to submit the test certificate f or the cable.
Make Finolex or Havells or KEI or Polycab or RPG or CCI.
500
-
-
Laying of 3C x 25 Sq. mm, Stranded Copper Conduct , Laying of 3C x 25 Sq. mm, Stranded Copper Conduct or , XLPE insulated, extruded inner PVC sheet, flat strip or wire armoured and overall PVC outer sheathed 1.1 KV grade cable, as per IS 7098 Part I on existing cable tray or wall or surface or as required.
Note Existing cable tray is at an elevation of approx. 3 4 meter.
500
-
-
Supply of 3C x 10 Sq. mm, Stranded Copper Conduct , Supply of 3C x 10 Sq. mm, Stranded Copper Conduct or , XLPE insulated, extruded inner PVC sheet, flat strip or wire armoured and overall FRLS PVC outer sheathed 1.1 KV grade cable, as per IS 7098 Part I with latest amendment as required.
Note Party to submit the test certificate f or the cable.
Make Finolex or Havells or KEI or Polycab or RPG or CCI.
200
-
-
Laying of 3C x 10 Sq. mm, Stranded Copper Conduct , Laying of 3C x 10 Sq. mm, Stranded Copper Conduct or , XLPE insulated, extruded inner PVC sheet, flat strip or wire armoured and overall PVC outer sheathed 1.1 KV grade cable, as per IS 7098 Part I on existing cable tray or wall or surface or as required.
Note Existing cable tray is at an elevation of approx. 3 4 meter.
200
-
-
Supply of 4C x 6 Sq. mm, Stranded Copper Conduct , Supply of 4C x 6 Sq. mm, Stranded Copper Conduct or , XLPE insulated, extruded inner PVC sheet, flat strip or wire armoured and overall FRLS PVC outer sheathed 1.1 KV grade cable, as per IS 7098 Part I with latest amendment as required.
Note Party to submit the test certificate f or the cable.
Make Finolex or Havells or KEI or Polycab or RPG or CCI.
500
-
-
Laying of 4Cx 6 Sq. mm, Stranded Copper Conduct , Laying of 4Cx 6 Sq. mm, Stranded Copper Conduct or , XLPE insulated, extruded inner PVC sheet, flat strip or wire armoured and overall PVC outer sheathed 1.1 KV grade cable, as per IS 7098 Part I on existing cable tray or wall or surface or as required.
Note Existing cable tray is at an elevation of approx. 3 4 meter.
500
-
-
Supply of 3C x 2.5 Sq. mm, Stranded Copper Conduct , Supply of 3C x 2.5 Sq. mm, Stranded Copper Conduct or , XLPE insulated, extruded inner PVC sheet, flat strip or wire armoured and overall FRLS PVC outer sheathed 1.1 KV grade cable, as per IS 7098 Part I with latest amendment as required.
Note Party to submit the test certificate f or the cable.
Make Finolex or Havells or KEI or Polycab or RPG or CCI.
100
-
-
Laying of 3Cx 2.5 Sq. mm, Stranded Copper Conduct , Laying of 3Cx 2.5 Sq. mm, Stranded Copper Conduct or , XLPE insulated, extruded inner PVC sheet, flat strip or wire armoured and overall PVC outer sheathed 1.1 KV grade cable, as per IS 7098 Part I on existing cable tray or wall or surface or as required.
Note Existing cable tray is at an elevation of approx. 3 4 meter.
100
-
-
Supply of 12Cx1.5.sq mm, 1.1 KV grade, XLPE insulated , Supply of 12Cx1.5.sq mm, 1.1 KV grade, XLPE insulated, and overall sheathed, stranded copper conduct or , flat steel strip or wire armoured control cables conf or ming to IS 7098 or Part I with latest amendments and of following sizes. Note The cables or drum shall bear ISI certification mark and party to submit the test certificate f or cables.
Make Finolex or Havells or RPG or Polycab or Glostar or Lapp or KEI or Rallision
Note Party to submit the type test certificate f or the cables.
400
-
-
Laying and fixing of one number 12Cx1.5Sqmm PVC insulated , Laying and fixing of one number 12Cx1.5Sqmm PVC insulated and PVC sheathed or XLPE Control cable of 1.1 KV grade on existing cable tray as required.
400
-
-
Supply of indo or end termination 3Cx25 sq.mm , Supply of indo or end termination with nickel coated brass double compression gland and Copper lugs f or 3Cx25 sq.mm size of XLPE insulated , PVC inner sheath, flat strip armoured and overall FRLS PVC outer sheathed copper conduct or cable of 1.1 KV grade as required
Make Dowells or 3M or Hex or Comat or Johnson
20
-
-
Making of indo or end termination 3Cx25 sq.mm , Making of indo or end termination with nickel coated brass double compression gland and Copper lugs f or 3Cx25 sq.mm size of XLPE insulated, PVC inner sheath, flat strip armoured and overall FRLS PVC outer sheathed copper conduct or cable of 1.1 KV grade as required
20
-
-
Supply of indo or end termination 3Cx10 sq.mm , Supply of indo or end termination with nickel coated brass double compression gland and Copper lugs f or 3Cx10 sq.mm size of XLPE insulated , PVC inner sheath, flat strip armoured and overall FRLS PVC outer sheathed copper conduct or cable of 1.1 KV grade as required
Make Dowells or 3M or Hex or Comat or Johnson
12
-
-
Making of indo or end termination 3Cx10 sq.mm , Making of indo or end termination with nickel coated brass double compression gland and Copper lugs f or 3Cx10 sq.mm size of XLPE insulated, PVC inner sheath, flat strip armoured and overall FRLS PVC outer sheathed copper conduct or cable of 1.1 KV grade as required
12
-
-
Supply of indo or end termination for 4Cx6 , Supply of indo or end termination with nickel coated brass double compression gland and Copper lugs f or 4Cx6 sq.mm size of XLPE insulated , PVC inner sheath, flat strip armoured and overall FRLS PVC outer sheathed copper conduct or cable of 1.1 KV grade as required
Make Dowells or 3M or Hex or Comat or Johnson
24
-
-
Making of indo or end termination 4Cx6 sq.mm , Making of indo or end termination with nickel coated brass double compression gland and Copper lugs f or 4Cx6 sq.mm size of XLPE insulated, PVC inner sheath, flat strip armoured and overall FRLS PVC outer sheathed copper conduct or cable of 1.1 KV grade as required
24
-
-
Supply of indo or end termination 3Cx2.5 sq.mm , Supply of indo or end termination with nickel coated brass double compression gland and Copper lugs f or 3Cx2.5 sq.mm size of XLPE insulated , PVC inner sheath, flat strip armoured and overall FRLS PVC outer sheathed copper conduct or cable of 1.1 KV grade as required
Make Dowells or 3M or Hex or Comat or Johnson
2
-
-
Making of indo or end termination 3Cx2.5 sq.mm , Making of indo or end termination with nickel coated brass double compression gland and Copper lugs f or 3Cx2.5 sq.mm size of XLPE insulated, PVC inner sheath, flat strip armoured and overall FRLS PVC outer sheathed copper conduct or cable of 1.1 KV grade as required
2
-
-
Supply of 12Cx1.5.sq mm Size indo or end termination , Supply of 12Cx1.5.sq mm Size indo or end termination with nickel coated, brass double compression gland and Copper lugs f or Copper conduct or , XLPE insulated, 1.1 KV grade cable as required, Make Dowells or Commet or Hex or 3M
20
-
-
Making of 12Cx1.5Sqmm size indo or end termination , Making of 12Cx1.5Sqmm size indo or end termination with nickel coated, brass double compression gland and Copper lugs f or Copper conduct or , XLPE insulated, 1.1 KV grade control cable as required,
20
-
-
Supply of indo or end terminationr 3.5C x 240 sq.mm , Supply of indo or end termination with nickel coated brass double compression gland and Aluminium lugs f or 3.5C x 240 sq.mm size of XLPE insulated , PVC inner sheath, flat strip armoured and overall PVC outer sheathed copper conduct or cable of 1.1 KV grade as required.
Make Dowells or 3M or Hex or Comat or Johnson
2
-
-
Making of indo or end termination 3.5C x 240 sq.mm , Making of indo or end termination with nickel coated brass double compression gland and Aluminium lugs f or 3.5C x 240 sq.mm size of XLPE insulated , PVC inner sheath, flat strip armoured and overall PVC outer sheathed copper conduct or cable of 1.1 KV grade as required.
2
-
-
Supply of indo or end termination 3.5C x 120 sq.mm , Supply of indo or end termination with nickel coated brass double compression gland and Aluminium lugs f or 3.5C x 120 sq.mm size of XLPE insulated , PVC inner sheath, flat strip armoured and overall PVC outer sheathed copper conduct or cable of 1.1 KV grade as required.
Make Dowells or 3M or Hex or Comat or Johnson
2
-
-
Making of indo or end termination 3.5C x 120 sq.mm , Making of indo or end termination with nickel coated brass double compression gland and Aluminium lugs f or 3.5C x 120 sq.mm size of XLPE insulated , PVC inner sheath, flat strip armoured and overall PVC outer sheathed copper conduct or cable of 1.1 KV grade as required.
2
-
-
Rerouting of the 3.5Cx 240Sqmm stranded Aluminium , Rerouting of the 3.5Cx 240Sqmm stranded Aluminium, XLPE insulated, extruded inner PVC sheet, flat strip armoured and overall PVC outer sheathed 1.1 KV grade cable on the existing cable tray as required.
10
-
-
Laying and fixing of one number PVC insulated and PVC , Laying and fixing of one number PVC insulated and PVC
sheathed or XLPE power cable of 1.1 KV grade of size above 95 sq. mm and upto 185 sq. mm clamped with
25 or 40x3mm MS flat clamp on cable tray as required.
Note Cable shall be provided by SCL free of cost.
30
-
-
Supply of 300 mm W x 50 mm D x1.6 mm T size , Supply of 300 mm W x 50 mm D x1.6 mm T size, hot dipped galvanised Iron ladder type cable tray including supply of supp or t materials such as unistrut, clamping rods, nuts, bolts, washers etc. as required. Make CABLOFIL or OBO or Land T or Profab or Sintex or equivalent.
30
-
-
Installation of 300 mm W x 50 mm D x1.6 mm , Installation of 300 mm W x 50 mm D x1.6 mm T size, perf or ated,hot dipped galvanised Iron ladder type cable tray including supp or t materials such as unistrut, clamping rods, nuts, bolts, washers etc. and min or civil w or k as required.
30
-
-
Supply of 150mm W x50 mm D x1.6 mm T size , Supply of 150mm W x50 mm D x1.6 mm T size of perf or ated pre galvanised finish galvanising as per IS 277 Cable Tray with perf or ation not m or e than 17.5 percent in convenient section, joined with connect or s, with clamps of cable tray including supply of supp or t materials such as unistruds, clamping rids etc. as required
Make Sintex or Land T or 3M or Profab or Legrand or OBO Bettermann or equivalent
50
-
-
Installation of 150mm W x50 mm D x1.6 mm , Installation of 150mm W x50 mm D x1.6 mm T size of perf or ated pre galvanised finish Cable Tray including min or civil w or k as required
50
-
-
Supply of 50mm W x50 mm D x1.6 mm T size , Supply of 50mm W x50 mm D x1.6 mm T size of perf or ated pre galvanised finish galvanising as per IS 277 Cable Tray with perf or ation not m or e than 17.5 percent in convenient section, joined with connect or s, with clamps of cable tray including supply of supp or t materials such as unistruds, clamping rids etc. as required
Make Sintex or Land T or 3M or Profab or Legrand or OBO Bettermann or equivalent
50
-
-
Installation of 50mm W x50 mm D x1.6 mm T size , Installation of 50mm W x50 mm D x1.6 mm T size of perf or ated pre galvanised finish Cable Tray including min or civil w or k as required
50
-
-
Supply of 25 mm X 5 mm GI strip , Supply of 25 mm X 5 mm GI strip along with G.I. nut, bolt, spring, washer etc. as required f or earthing of Electrical panel.
Make Reputed.
50
-
-
Fixing 25 mm X 5 mm GI strip , Fixing 25 mm X 5 mm GI strip f or earthing on surface or in recess f or connections etc. as required,including connection or terminating with G.I. nut, bolt, spring, washer etc. as required. Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt and spring washer spaced at 50mm .
50
-
-
Providing of 8 SWG dia G.I. wire on surface , Providing of 8 SWG dia G.I. wire on surface or in recess f or loop earthing as required.
Make Reputed
100
-
-
Fixing 8 SWG dia G.I. wire on surface , Fixing 8 SWG dia G.I. wire on surface or in recess f or loop earthing as required.
100
-
-
Supply of outdo or type junction box 630mm x 300mm x 250mm , Supply of outdo or type junction box having size 630mm x 300mm x 250mm, MS sheet , single front construction, Powder coated IP 54, non compartmental, 3 mm thick removable gland plate, f or bottom entry, lug and ferrules at both side of control wiring, Aluminium name plate on front hinged do or , 2 nos earth stud with 100 no of elmex type malamine terminal blocks etc.
Note Necessary hardware such as fastener, MS powder coated frame etc f or installion of the Junction Box on wall shall be supplied by the vend or .
Make As per Approved Panel List attached .
2
-
-
ITC of outdo or type junction box 630mm x 300mm x 250mm , Installation , testing Commissioning of outdo or type junction box 630mm x 300mm x 250mm on wall as required.
2
-
-
Supply of Earthing with maintenance free copper coated Earth rod , Supply of Earthing with maintenance free copper coated Earth rod of 3 Mtr length 20 mm dia earth rod with necessary coupler and connect or , universal clamps, inspection chamber,earth conductivity enhancing mineral compound of required quantity and providing earth chamber including material to interconnect with earth strips complete as required as per IS 60364 and IS 3043 with latest amendments.
Make OBO Bettermann or Terec or Erico or L or ess or Ashlok or JMV lps or equivalent
2
-
-
Installtion of Maintenance free earth pit including necessary civil works , Installtion of Maintenance free earth pit including necessary civil w or ks such as excavation, laying of chemcials, installing the rod, necessary holes, interconnect with earth strips complete, making the chamber and paintaing the same with green colour as required.
2
-
-
Supplying of 25 mm X 5 mm G.I strip , Supplying of 25 mm X 5 mm G.I strip including necessary hardware such as G.I. nut, bolt, spring, washer etc. as required.
50
-
-
Laying of 25 mm X 5 mm G.I strip at 0.50 , Laying of 25 mm X 5 mm G.I strip at 0.50 including connection or terminating with G.I. nut, bolt, spring, washer etc. as required. Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt and spring washer spaced at 50mm
50
-
-
Dismantling of existing MCC Panel Approx length 4.5 meter , Dismantling of existing MCC Panel Approx length 4.5 meter located at Ground flo or of ESG Building after dismantling of the Power or Control cables and shifting the same at the designated location within SCL permises
1
-
-
Dismantling of existing MCC Panel Approx length 1 meter , Dismantling of existing MCC Panel Approx length 1 meter located at Ground flo or of ESG Building after dismantling of the Power or Control cables and shifting the same at the designated location within SCL permises
1
-
-
Dismantling of the existing power and control cabless , Dismantling of the existing power and control cabless upto size of 25 Sqmm from cable tray at a height of 3 4 meter and shifting the same to the designated location in SCl permises.
200
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%