If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 48,487Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_BSF_835878_1Tender No
138/Engg(E)/Tender/Ftr PB/2024-25Tender Authority
Border Security Force ViewPurchaser Address
-Website
http://http://bsf.nic.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
DEVELOPMENT OF BSF CAMPUS FAZILKA OF 52 BN BSF UNDER SHQ BSF ABOHAR SH SITC OF SUB STATION EQUIPMENTS
DEVELOPMENT OF BSF CAMPUS FAZILKA OF 52 BN BSF UNDER SHQ BSF ABOHAR SH SITC OF SUB STATION EQUIPMENTS
BOQ Items
Providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required
10
1235
12355
Providing and fixing H.T. danger notice plate of 250 mm x 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
2
76
153.1
Providing and fixing M. V. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on fron side as required.
2
57
114.82
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 grades stone aggregate 40 mm nominal size)
1
6931
6931
Providing and fixing 11 KV HT insulation sleev and HT insulation tape in transformer open copper bar etc. as required.
1
323
323
Providing and making temporary arrangements for connection of 11 KV HT line from main incomer cable to out side over head 11 KV distribution system including disconnection of old cable from OCB and making new connection to new 11 KV 3x95 sqmm, Laying cable outside from sub-station etc as req.
1
1490
1490
Dismantling the existing panel, copper ear thing strip, incoming and outgoing cable connections, switchgears, ACB’s, bus bars, including shifting the panel from the existing site and taking out from the sub station.
1
5000
5000
SITC of indoor type compartmentalized cubical panel of size suitable for 415 Volt, 3 phases, 50 Hz made out of 2mm thick CRCA sheet and depth up to 800 mm with required hardware duly painted with powder coated. The panel having separate detachable gland plate, hinged door, with locking arrangement, earth bar/stud, 1000A/415V 4 strip aluminum bus bar duly PVC sleeved, including electrical mechanical interlocking, connection inter–connection for incoming/Outgoing cables with the required current capacity bus bar links (as per direction of Engg in charge), space for 800A 4 Pole Air Circuit Breakers, bus couplers for two transformers, MCCBs. The panel should be mounted on MS Base frame 75 mm x 40 mm x 5mm of suitable size and should have the provision of following instruments mounted and including provision of outgoing cable connections bus bar links of required current carrying capacity etc as required. (Indoor Panel should be as per design & drawing approved by Engg in charge and comprising of Instruments):- a) 0-500 Volts, Digital voltmeter of size 96 Sqmmx96 sqmm with Selector switch-02 Set
b) 0-1000 Amps, Digital Ammeter of size 96Sqmmx96sqmm type with Selector switch -02 set
c) LED Pilot light (22.5 MM dia) with protection MCB’s- 06Nos)
d) Alarm System - 01 Nos
e) Exhaust Fan for panel - 01Nos.
6
40000
240000
Providing and fixing of following accessories in the above/existing cubical panel as mentioned in the existing/new panels i/c connection inter-connection with aluminum bus bar of required size and current carrying
capacity etc as required as per direction of Engg in charge. (In item No 12)
-
-
-
800A, Air circuit breaker breaking capacity 50 KA manual draw out type 3 Pole Microprocessor based ET trip systems with thermal memory Conforms to IS/ IEC 60947-2 & 3,Zone Selective Interlocking, Fully rated neutral with inbuilt protection, Pre trip alarm & individual fault indicating LEDs ACB/Bus bar coupler MVS08N3MW6L comprising of Overload, Short-circuit, Instantaneous & Earth-fault
protections Schneider or equvilent make.
2
149200
298400
800A, Air circuit breaker breaking capacity 50 KA manual draw out type 4 Pole Microprocessor based ET trip systems with thermal memory Conforms to IS/ IEC 60947-2 & 3,Zone Selective Interlocking, Fully rated neutral with inbuilt protection, Pre trip alarm & individual fault indicating LEDs ACB/Bus bar coupler MVS08N4MW6L comprising of Overload, Short-circuit, Instantaneous & Earth-fault protections Schneider or equvilent make.
1
176000
176000
400 A 36 KA TP MCCB with thermo magnetic release cat no LV540306 Schneider
1
27000
27000
250A TP 25 KA MCCB with thermo magnetic release cat no LV525333 Schneider
4
17500
70000
125 A TP MCCB 25KA with thermal magnetic release LV516332 Schneider
2
9900
19800
Providing and fixing of tape wound current transformer 1000/5 in the existing panel i/c connections with 1.5 sqmm pvc copper wire in the existing panel at SN 3 (AE/L&T/Scheinder make)
6
950
5700
Spreader Links for 400 Amp TP MCCB
1
1250
1250
Spreader Links for 250 Amp TP MCCB
6
550
3300
Spreader Links for 125 Amp TP MCCB
2
550
1100
Extended Rotary handle for 400 Amp TP MCCB
1
2850
2850
Extended Rotary handle for 250 Amp TP MCCB
6
1600
9600
Extended Rotary handle for 125 Amp TP MCCB
2
1600
3200
Electrical & Mechanical interlocking for circuit breakers
1
10900
10900
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%