Border Security Force Tender
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 92,173Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_BSF_834652_1Tender No
160/Engg(E)/Tender/Ftr PB/2024-25Tender Authority
Border Security Force ViewPurchaser Address
-Website
http://http://bsf.nic.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Providing and fixing 25 mm x 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
30
1649
49470
Providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required
10
1236
12360
Providing and fixing H.T. danger notice plate of 250 mm x 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
2
78
156
Providing and fixing M. V. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
2
60
120
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 grades stone aggregate 40 mm nominal size)
3
6518
19554.54
Earth work in excavatino by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
10
260
2603
Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc.. with charcoal / coke and salt as required.
1
7945
7945
Providing and fixing 25 mm x 3 mm G.I. Strip on surface/on ground or in recess for connections etc. as required.
12
259
3108
Providing and fixing 150 mm dia G.I. pipe (medium class) with suitable size GI clamps of size 150x3 mm alongwith existing C channel for cable protection etc. as required.
6
2089
12534
Providing and fixing of Checkered plate 7 mm thick (MS) at HT panel cable trench i/c cutting, placing and position and red oxide primer of plate etc as req.
130
131
17030
Providing and fixing of MS channel of size 75mm x 40mm x 4.8mm i/c cutting, placing and position and red oxide primer of channel etc as req.
41
110
4510
Supplying and fixing of shock treatment chart with card board in HT panel room at sub-station room etc as req.
1
660
660
Providing and fixing 11 KV HT insulation sleev and HT insulation tape in transformer open copper bar etc. as required.
1
339
339
Providing and making temporary arrangements for connection of 11 KV HT line from main incomer cable to out side over head 11 KV distribution system including disconnection of old cable from OCB and making new connection to new 11 KV 3x95 sqmm, Laying cable outside from sub-station etc as req.
1
1490
1490
Dismantling the existing panel, copper earthing strip, incoming and outgoing cable connections, switchgears, ACB’s, bus bars, including shifting the panel from the existing site and taking out from the sub station.
1
11912
11912
SITC of indoor type compartmentalized cubical panel of size suitable for 415 Volt, 3 phases, 50 Hz made out of 2mm thick CRCA sheet with required hardware duly painted with powder coated. The panel having separate detachable gland plate, hinged door, with locking arrangement, earth bar/stud, 1000A/415V 4 strip aluminum bus bar duly PVC sleeved, including electrical mechanical interlocking, connection inter–connection for incoming/Outgoing cables with the required current capacity bus bar links (as per direction of Engg in charge), space for 800A 4 Pole Air Circuit Breakers, bus couplers for two transformers, MCCBs. The panel should be mounted on MS Base frame 75 mm x 40 mm x 5mm of suitable size and should have the provision of following instruments mounted and including provision of outgoing cable connections bus bar links of required current carrying capacity etc as required. (Indoor Panel should be as per design & drawing approved by Engg in charge and comprising of) Instruments Panel S/Stn No-01:-
a) 0-500 Volts, Digital voltmeter of size 96 Sqmm x 96 sqmm with Selector switch-02 Set b) 0-1000 Amps, Digital Ammeter of size 96Sqmmx96sqmm type with Selector switch -02 set c) LED Pilot light (22.5 MM dia) with protection MCB’s-06Nos) Size of panel for Main Sub Station 800mm depth
5
32000
160000
Providing and fixing of following accessories in the above/existing cubical panel as mentioned in the existing/new panels i/c connection inter-connection with aluminum bus bar of required size and current carrying capacity etc as required as per direction of Engg in charge. Incomer: a)800A, Air circuit breaker breaking capacity 50 KA manual draw out type 4 Pole Microprocessor based ET trip systems with thermal memory Conforms to IS/ IEC 60947-2 & 3, Zone Selective Interlocking, Fully rated neutral with inbuilt protection, Pre trip alarm & individual fault indicating LEDs ACB/Bus bar coupler MVS08N4MW6L comprising of Overload, Short-circuit, Instantaneous & Earth-fault protections Schneider 01 nos b) 800A, Air circuit breaker breaking capacity 50 KA manual draw out type 3 Pole Microprocessor based ET trip systems with thermal memory Conforms to IS/ IEC 60947-2 & 3,Zone Selective Interlocking, Fully rated neutral with inbuilt protection, Pre trip alarm & individual fault indicating LEDs ACB/Bus bar coupler MVS08N3MW6L comprising of Overload, Short-circuit, Instantaneous & Earth-fault protections Schneider 02 nos c) 250A 36 KA MCCB with thermo magnetic release cat noLV525333with ROM and spreader links Schneider 06 nos d)125ATP MCCB 25KA with thermal magnetic release L&T make with ROM and spreader links LV516302Schneider 02 nos
1
710000
710000
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%