Bharat Sanchar Nigam Limited Tender

If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Bharat Sanchar Nigam Limited - BSNL Tender

Works
Security and Emergency Services
Eprocure
Opening Date29 Nov 2023
Closing Date8 Dec 2023
Tender Amount₹ 3,29,425 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Starter for FTL

40

-

-

... More
S/F Following items in the existing TLN11 CFL fittings i/c dismantling of old faulty items complete with making interconnection etc complete as required.

-

-

-

... More
Copper wound choke suitable for 11Watt above fitting.

2

-

-

... More
11Watt CFL Lamp

4

-

-

... More
Supplying and fixing following amps rating, 240/415 volts, MCB breaker following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
Single Pole (5-32A)

2

-

-

... More
Double Pole (5-32A)

2

-

-

... More
Tripple Pole & Neutral (63A)

4

-

-

... More
Providing rewinding to the existing ceiling fan/ Exhaust fan complete with dismantling of existing ceiling / Exhaust and pulling out of old burnt winding and replacing the same with copper winding complete with varnishing, drying and re-assembling complete with testing and commissioning etc as required.

-

-

-

... More
48"/56" sweep ceiling fan

2

-

-

... More
18" sweep exhaust Fan

2

-

-

... More
12" sweep exhaust Fan

1

-

-

... More
Wall Fan 16"

2

-

-

... More
SITC of Heavy duty Exhaust Fan of 400mm sweep complete with all accessories such as motor, blade, base etc as supplied by the manufacturer and making interconnection with 1.5SQMM FRLS PVC insulated copper conductor cable etc as required.

1

-

-

... More
Replacement of following items and other accesories in the existing MV panel/LT Panel/Main distribution Board/panel i/c dismentalling the old item and fixing new item,interconnections complete etc required.

-

-

-

... More
Indication lamps LED Type

6

-

-

... More
Ammeter ( 0-100 amp) 96mm X 96mm

2

-

-

... More
Selector Switch for ammeter with OFF

2

-

-

... More
Voltmeter (0-500V) 96mm X 96mm

2

-

-

... More
Selector Switch for Voltmeter with OFF

2

-

-

... More
4 pole 250 Amp MCCB ,Breaking cap 25 KA

1

-

-

... More
S/F Following items in HT Panel i/c dismantling the faulty ones & Making interconnection etc as required.

-

-

-

... More
Voltmeter (0-20KV) 144mm X 144mm

2

-

-

... More
Ammeter (0-100 A) 144mm X 144mm

2

-

-

... More
50V DC Lamp

4

-

-

... More
Selector switches for voltmeter

2

-

-

... More
Selector switches for Ampere meter

2

-

-

... More
LED type indicators

6

-

-

... More
Push Buttons

4

-

-

... More
Making the arrangement for insulation testing of HT bus bar in the HT panel with the help of 5000 V meggar & reconnection of HT insulator in HT Panel etc complete as reqd.

1

-

-

... More
Servicing of OCB in HT panel i/c moving out the OCB from HT Panel, cleaning and replacing of burnout contacts/insulators and cleaning of entire bus bar , tightening of nuts and bolts of interconnections etc. and pdg. missing nuts & blots of covers and other related Acc. /Items like gaskets etc. complete as per requirement at site. complete as required.

2

-

-

... More
Servicing of HT isolator i/c cleaning and replacing of burnout contacts/insulators and cleaning of entire bus bar , tightening of nuts and bolts of interconnections etc. and pdg. missing nuts & blots of covers and other related Acc. /Items like gaskets etc. complete as per requirement at site. complete as required.

1

-

-

... More
Providing repairs to the existing IDMT relays i/c calibration of the same connections, testing and commissioning as per the directions of the engineer in charge.

2

-

-

... More
Topping up of transformer oil in the existing HT OCB/PT etc. comp. as reqd.

30

-

-

... More
Replacement of following components in the existing DEA control panel i/c dismantling of old defective parts complete with making interconnections etc complete as required.

-

-

-

... More
200 amp rating three pole MCCB of 25kA breaking capacity

1

-

-

... More
Providing and bringing the existing control wiring into working order i/c making all controls, meters, safeties in working order complete with making the engine operational from control panel etc complete as required i/c P/F copper conductor control cable as per specifications of the department etc as required. (Note: this item does not include cost of safeties, meters, push button etc)

2

-

-

... More
Providing and fixing 1/2" dia wire braided fuel pipe complete with machine made end connections with benzo bolt etc complete as required.

5

-

-

... More
Repairing / replacement of following defective components in existing conventional type fire panel and and local control panel of automatic fire detection and alarm system including dismantalling the old defective parts and fixing of new ones interconnections , testing complete etc as required.

-

-

-

... More
Zone card

2

-

-

... More
Power Supply card

1

-

-

... More
Hooters 12V/24V

1

-

-

... More
Response Indicator ( 2 LED Type )

2

-

-

... More
SITC of sealed maintenance free batteries , 12V, 26 Ah capacity in existing compartment below Main control panel including interconnections complete etc as required.

2

-

-

... More
Repairing of existing public address system(PA system)i/c testing with mike ,amplifier , interconnections complete etc as required.

1

-

-

... More
Supplying, Installation, Testing and Commissioning of photo electric smoke detector with a detector junction box. The detector should incorporate solid-state LED and high speed, High sensing photo diode within sensing chamber including other accessories etc. as required as per makes and specifications attached i/c dismantling the existing detectors wherever required. The base shall be of the same make as that of detector.(Make:- BSNL approved make)

2

-

-

... More
Supply, installation, fixing, testing and commissioning of fixed temperature cum rate of rise heat detectors with Thermistor as temperature sensing element as per makes and specifications attached. i/c dismantelling the existing detectors wherever required (Make:- BSNL approved make)

2

-

-

... More
Refilling of existing 4.5 kg CO2 fire extinguishers as per the directions of the engineer in charge

16

-

-

... More
Supplying and fixing following items in the existing 4.5 kg CO2 fire extinguishers i/c testing and commissioning etc as reqd.

-

-

-

... More
Horns i/c pipe

10

-

-

... More
Fabricating & installing GI pipe of 80 mm dia ( Medium class "B") of length 1.2 mtr with cross arm welded at bottom fabricated out of 2 nos 400 mm long 35x35x5 mm MS angle iron pieces and suitable size GI socket at top (for welding existing broken pole in this socket),including excavating the soil for GI pipe fixing ,refilling etc complete as reqd.(GI pipe will be dug up to 1 mtr height in ground and 200 mm above ground for fixing socket and welding the broken pole)

4

-

-

... More
Fabricating /making muffin /PCC foundation(1:3:6) around base of compound light pole of 300 mm dia and 1.6 m height (1 mtr below ground level and 0.6 mtr above ground))complete including plastering the sides and painting etc as required.

5

-

-

... More
Supplying and fixing following items in the existing 2x18 W Crompton CFL compound light fitting i/c fixing the same, connections, testing and commissioning etc. comp. as reqd.

-

-

-

... More
2X18Watt choke

10

-

-

... More
CFL 18 W 2Pin

22

-

-

... More
Acrylic covers

8

-

-

... More
11Watt Gate Light Fitting complete with holder,CFL/LED & acrylic cover etc as required.

1

-

-

... More
Plastic moulded pole box complete with connector & din for installing MCB i/c P/F suitable size MCB etc i/c making interconnection etc as required.

2

-

-

... More
Supplying and fixing 1000 watt halogen rod in the existing 1000watt halogen fitting suitable for operation on single phase 230 volts AC supply i/c making connections, testing and commissioning etc comp. as reqd.

1

-

-

... More
Replacement of following items in the existing window/split ac units suitable for operataion on single phase AC supply i/c making connections, testing and commissioining etc comp. as reqd.

-

-

-

... More
Operating Knob

1

-

-

... More
Thermostat

2

-

-

... More
Filter for WAC unit /SAC

2

-

-

... More
Providing charging of refrigerant in the existing WAC/SAC unit of 1.5TR rating complete with leakage testing and pressure testing complete with testing commissioning etc as required.

5

-

-

... More
Supplying and fixing new hermatically sealed reiprocating compressor in the indoor unit of existing package AC unit i/c making modifications required to suit the installation of new compressor in the existing package AC (as the of new compressors may be different in size from existing compressor , making connections with existing refrigerant pipings, suitable for operation on 3 phase 415 volts, 50 HZ AC supply i/c making connections, testing and commissioning etc comp. as reqd. (Make Kirloskar KCR 57/Emerson/Similar Superior Make).

2

-

-

... More
Supplying and charging refrigerant R-22 in the refrigerant cirucit of existing package AC units as per the standard proceedures and as per the directions of engineer in charge comp. as reqd.

22

-

-

... More
Rewinding of condenser fan motor of outdoor unit of Package type AC Unit i/c change of bushes etc i/c dismentling and fixing etc. complete as reqd.

2

-

-

... More
Rewinding of Blower fan motor of Indoordoor unit of Package type AC Unit i/c change of bushes etc i/c dismentling and fixing etc. complete as reqd.

1

-

-

... More
Providing and carrying out Nitrogen pressure testing, leak testing, evacuation of the entire refrigerant cirucit of existing package AC unit i/c pressure testing with Nitrogen, leak testing with hallide torch and soap solution, attending the leakage if any, vacumising etc comp. as per the directions of engineer in charge. The entire tests to be carried out in this item shall be carried out as per standard proceedure so as to ensure that there is no leakage in the refrigerant circuit before charging of refrigerant.

2

-

-

... More
Providing and fixing liquid line filter drier with hand shut off valves and flare nuts in the existing refrigerant line i/c dismantling the old choked drier and fixing the new one.(Note: The old faulty drier and hand shut off valves shall be the property of the agency. The rates should be quoted accordingly).

2

-

-

... More
Providing and fixing following items in the existing 7TR package AC units i/c making connections with the existing refrigerant circuit etc comp. As reqd.

-

-

-

... More
(a) Dial Type Discharge Pressure Gauge (0-500 PSI)

6

-

-

... More
(b) Dial Type Suction Pressure Gauge(0-300 PSI)

6

-

-

... More
Replacement of the following faulty components in existing 7TR Package type air conditioner i/c dismantling of old faulty component & fixing of new one and testing commissiong etc as reqd

-

-

-

... More
(i) Repair/Replacement of Control Card of 7TR AC Package unit

1

-

-

... More
(ii) Minilec VSP D2 SPP

5

-

-

... More
(iii) 63 Amp four pole MCB, 440 Volts

2

-

-

... More
Providing and fixing following components in the existing capacitor panel suitable i/c making connections, testing and commissioning etc comp. As reqd.

-

-

-

... More
3 Pole Capacitor duty contactorss suitable for operation on 3phase 415/440V AC supply i/c connections, testing and commissioning etc. Comp. As reqd.

-

-

-

... More
(i)10 KVAR

1

-

-

... More
(ii)20 KVAR

1

-

-

... More
Heavy duty capacitor suitable for operation on 3 Ph 440 V, 50 Hz AC supply of following rating

-

-

-

... More
(i) 10 KVAR Heavy Duty Cylindrical Capacitor

1

-

-

... More
(ii) 20 KVAR Heavy Duty Cylindrical Capacitor

1

-

-

... More
Servicing of the existing capacitor panel compartments, making necessary modifications in the existing capacitor panel and rearranging the existing capacitors i/c providing missing nuts, bolts, tightening of connections, adjustment of APFC relay etc comp. As reqd.

1

-

-

... More
IMPORTANT NOTE :- 1) GST is implemented. The tax will be regulated accordingly and the credit will be transferred to BSNL as per new rules.

-

-

-

... More
2) For claiming GST payment the vendor should raise GST invoice as per point No. 8 (GST invoice) of Vendor Contract Clauses of this NIT.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.