Baba Farid University Of Health Sciences Tender

If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Baba Farid University Of Health Sciences - BFUHS Tender

Electrical and Electronics
Electrical Works
Eprocure
Opening Date10 Jun 2021
Closing Date18 Jun 2021
Tender Amount₹ 98,04,147 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

  • EMD

    ₹ 1,99,200
  • Document Cost

    ₹ 3,540
  • Tender Fee

    ₹ 2,360

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Supply installing Commissioning of HVAC Services for Modular Operation Theaters
Supply installing Commissioning of HVAC Services for Modular Operation Theaters
Price Bid for Supply installing Commissioning of HVAC Services for Modular Operation Theaters
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
The Vertical Floor mounted AHU with Themal Break Profile shall be having minimum panel thickness of 25 mm with following parts. Prefilter section with prefilters, 6 Row cooling coil, 60 mm Static Backward curved DIDW/ Plug type blower with TEFC high efficiency motor, Fine filter section with fine filters, supply air dampers. 2500 CFM ( passage TF)

1

-

-

... More
The Ceiling suspended AHU with Themal Break Profile shall be having minimum panel thickness of 40 mm with following parts. Prefilter section with prefilters, 6 Row cooling coil, 55 mm Static Backward curved DIDW/ Plug type blower with TEFC high efficiency motor, Fine filter section with fine filters, supply air dampers. 2500 CFM ( Sterile Corridor, Post OT)

1

-

-

... More
The Ceiling Suspended AHU with Themal Break Profile shall be having minimum panel thickness of 40 mm with following parts. Prefilter section with prefilters, 6 Row cooling coil, 40 mm Static forward curved DIDW/ Plug type blower with TEFC high efficiency motor. 2500 CFM

1

-

-

... More
Supply, installation, testing and commissioning of 2-way motorized valves suitable for Chilled water as well as hot water application complete with Electrical / Electronic actuator, necessary wiring and required accessories for proper operation and control of valves of following sizes. (Vendor to submit the Selection sheets of the Control Valves for all sizes individually) 65mm dia pipe /50 mm 3 way valve

2

-

-

... More
50mm dia pipe /40 mm 3 way valve

6

-

-

... More
40 mm dia pipe /32 mm 3 way valve

1

-

-

... More
Supply, installation, testing and commissioning of cooling / heating thermostats for various Air Handling Units as per specifications including all accessories, mountings, wiring between thermostat & unit, terminations etc., complete in all respect as required and as per specifications. Proportional thermostats for Air Handling Units

6

-

-

... More
Supplying, installing, testing and commissioning of Fan coil unit, each complete with 3 rows deep chilled water coil, centrifugal fans, cleanable fabric filters, main condensate drain pans, auxiliary drain pan, as described in specifications, casing, coil piping connections, through copper pipes, condensate drain connections, wiring, control wiring in conduit upto thermostat boxes. All fan coil units shall be suitable for 220 + 6% volts, 50 cycles, single phase power supply. Fan Coil Units shall be of following refrigeration capacities as listed. 2.0 TR nominal capacity

4

-

-

... More
1.5 TR nominal capacity

1

-

-

... More
1.0 TR nominal capacity

4

-

-

... More
Supply, installation, testing and commissioning of controls for fan coil units consisting of 2-way motorized spring return valves, Snap acting type heating/cooling thermostat with fan speed switch, wiring etc. 25 mm dia valve

5

-

-

... More
20 mm dia valve

4

-

-

... More
Supplying, installing, testing and commissioning of CENTRIFUGAL MONOBLOC END SUCTION PUMPS, factory mounted on a common base with electric motor for recirculation of water for the central air conditioning system.  End suction design, in cast iron/ bronze fitted construction specifically designed for quiet operation for chilled water cooling systems as shown in the drawings. All pumps shall be provided with mechanical seal and aligned properly as required. The pump motor shall be suitable for 415 + 10% volts, 50 cycles, 3 phase power supply. The quoted price shall include cost of thermal insulation and cladding of pumps. Pumps with performance characteristics as given below: Chilled Water pumps 1 No MONOBLOC type pump. 1 No. Suitable HP, TEFC squirrel cage induction motor with class 'F' insulation, 2900 rpm, operating on 415 +/- 10% volts, 3 phase, 50 Hz A.C. supply.Lot - Expended Polystyrene (TF quantity) insulation not less than 50mm thick duly cladded between aluminum sheets of 0.5mm thickness and properly clamped to pump in two semicircular sections as per specifications. 2 nos. - 150 mm dia. dial type pressure gauges. Lot - Mounting frame with Anti vibration pads. Lot - RCC/cement concrete foundation for the pump unit. Operating parameters Water flow rate = 144 USGPM Head = 92 Ft. of water /28 M Motor HP = 7.5 (Suggested) Quantity indicated includes one standby

2

-

-

... More
Hot Water pumps 1 No MONOBLOC type pump. 1 No. Suitable HP, TEFC squirrel cage induction motor with class 'F' insulation, 2900 rpm, operating on 415 +/- 10% volts, 3 phase, 50 Hz A.C. supply. Lot - Expended Polystyrene (TF quantity) insulation not less than 50mm thick duly cladded between aluminum sheets of 0.5mm thickness and properly clamped to pump in two semicircular sections as per specifications. 2 nos. - 150 mm dia. dial type pressure gauges. Lot - Mounting frame with Anti vibration pads. Lot - RCC/cement concrete foundation for the pump unit. Operating parameters Water flow rate = 90 USGPM Head = 92 Ft. of water /28 M Motor HP = 5 (Suggested) Quantity indicated includes one standby

2

-

-

... More
Supplying, installation, testing and commissioning of electrical HW generator equipped with sufficient number of electrical immersion heaters. The pressure vessel shall be constructed and insulated on all sides with 100 mm thick fiber glass and cladded with 0.80 mm aluminum sheet in a neat and clean manner. The generator shall be equipped with all automatic and safety controls such as manual reset high temperature water outlet, step controller and recycling relay, 'ON' 'OFF' switch thermostats, pilot light, low water cutoff and other controls as per manufacturers recommendations. All controls and terminals shall be located in an integral control cabinet factory wired and tested. The generator shall be suitable for 415 (+)/(-) 10% volts, 50 cycle, 3 phase power supply. The entire generator shall be factory assembled and tested at 350 PSI pressure. The Hot Water Generator shall be of following capacity made of 8mm MS sheet and dish end made of 10mm MS having 16 gauge stainless steel lining with heaters arranged in banks and controlled by electronic Controller and Thermostats so that hot water is generated at 55 Deg C with nominal variation including necessary controls including inlet and outlet connections for water as per specifications complete with pressure release valve, low level cut-out. Autovent sight-glass, foundation for HWG as per specifications complete as required.100 KW

1

-

-

... More
Supply, installation, testing and commissioning of an insulated roof mounted chilled water expansion tank of PVC construction. The tank shall be complete with necessary connection for piping. Insulation shall be 50 mm thick expanded polystyrene covered with sand cement plaster. Each tank shall be of capacity minimum 1000 liters.

1

-

-

... More
Supply, installation, testing and commissioning of Humidistats for various Air Handling Units as per specifications including all accessories, mountings, wiring between Humidistat & unit, terminations etc., complete in all respect as required and as per specifications.

3

-

-

... More
Supply Installation Testing and commissioning of SS pan type Humidifier with controls, immersion type heaters, controls and humidistat. 6 KW

3

-

-

... More
Supply, installation, testing and commissioning of Inline ducted Fans with casing suitable for outdoor application for Fumigation/ Exhaust. 600 CFM

5

-

-

... More
300 CFM

2

-

-

... More
100 CFM

2

-

-

... More
Supply, installation, testing and commissioning of wall mounted propellor fans with casing suitable for exhaust. The dia of fan is 225 mm.

5

-

-

... More
PIPING MS Chilled water Pipe Supply, fixing in position, testing and commissioning of the following Below ground/Over ground MS class ‘C’ pipes of following diameter cut to required lengths and installed with all welded joints, complete with the necessary fittings like elbows, tees and reducers, sockets etc. excluding valves for Chilled / Hot water lines but including insulation as per specifications. 100 mm dia MS pipes

90

-

-

... More
80 mm dia MS pipes

110

-

-

... More
65 mm dia MS pipes

30

-

-

... More
50 mm dia MS pipes

30

-

-

... More
40 mm dia MS pipes

110

-

-

... More
32 mm dia MS pipes

40

-

-

... More
25 mm dia MS pipes

50

-

-

... More
20 mm dia MS pipes

30

-

-

... More
Providing and fixing in position the following Butterfly Valves duly insulated as per specifications. 100 mm dia valves

5

-

-

... More
80 mm dia Valves.

18

-

-

... More
65 mm dia Valves.

4

-

-

... More
50 mm dia Valves.

8

-

-

... More
Providing and fixing in position following Balancing Valves duly insulated as per specifications. 100 mm dia Valves.

1

-

-

... More
80 mm dia Valves.

5

-

-

... More
65 mm dia Valves.

2

-

-

... More
50 mm dia Valves.

4

-

-

... More
Providing and fixing in position following Check Valves duly insulated as per specifications. 100 mm dia valves

3

-

-

... More
Providing and fixing in position following Y-Strainer duly insulated as per specifications. 100 mm dia

6

-

-

... More
65 mm dia

6

-

-

... More
50 mm dia

4

-

-

... More
Supply Installation Testing of Ball Valve set with and without Strainer for Fan coil units 25 mm dia

5

-

-

... More
20 mm dia

4

-

-

... More
Supplying, installation, testing and commissioning of Auto air vents.

10

-

-

... More
Providing and fixing in position the industrial type pressure gauges with gun metal ball valves.

24

-

-

... More
Providing and fixing in position the mercury-in- glass industrial type thermometers.

16

-

-

... More
Providing and fixing in position the following PVC ( Min 3 mm thick) Heavy duty pipes cut to required lengths and installed with all screwed joints with the necessary elbows, tees and reducers etc duly insulated with 6 mm thick insulationas per specifications. 50mm dia pipes

10

-

-

... More
40mm dia pipes

50

-

-

... More
32 mm dia pipes

40

-

-

... More
25 mm dia pipes

30

-

-

... More
Providing and fixing in position flow switch

2

-

-

... More
AIR DISTRIBUTION Supply, Fabrication, installation and testing of sheet metal ducts in accordance with the approved shop drawings and as required by the specifications. 24 gauge GI sheet steel

150

-

-

... More
22 gauge GI sheet steel

100

-

-

... More
20 gauge GI sheet steel

50

-

-

... More
Supply, Fabrication, installation and testing of sheet metal ducts in accordance with the approved shop drawings and as required by the specifications. 22 gauge aluminium sheet steel

80

-

-

... More
20 gauge aluminium sheet steel

80

-

-

... More
Supply, fabrication, installation and testing the flexible connections constructed of fire resistance flexible double canvas sleeve as per the approved shop drawings.

15

-

-

... More
Supply, installation and testing of GI construction Louver dampers within ducts to be provided with suitable ducts lever and quadrants for manual control of volume of air flow and for proper balancing of the air distribution system.

3

-

-

... More
Fire Damper with Control Mechanism Supplying, fixing, testing and commissioning of motor actuated Fire Dampers of at least 1.5 hour fire rating in supply air duct at wall crossing of AHU room/as and where required, of requires sizes including control wiring. The damper shall be motorized and spring return so as to close the damper in the event of a fire signal which shall be provided by smoke sensor/detector in AHU room as per specifications and as required. The spring return action shall be in-built mechanism and not externally mounted. The control wiring shall be interlocked ion such a way that along with actuation of damper-closing mechanism, the AHU fan motor gets automatically switched off. Fire damper as described above, as per specifications and complete in all respects.

3

-

-

... More
Electric Actuator Electric actuator with necessary linkage to actuate fire dampers complete with required wiring and associated accessories. Note: Fire dampers shall be supplied with sensors/actuators/control etc duly factory fitted and tested at manufacturers works and certificate to this effect produced along with delivery of fire damper.

5

-

-

... More
Supply, installation, testing and balancing of powder coated extruded aluminum construction Discreet Air Grilles without volume control dampers.

5

-

-

... More
Supply, installation, testing and balancing of powder coated extruded aluminum construction Linear Air Grilles without volume control dampers.

5

-

-

... More
Supply, installation, testing and balancing of powder coated extruded aluminum square shape ceiling diffusers with removable core and anti smudge ring & aluminum volume control dampers as per specifications

5

-

-

... More
Supply, installation, testing and balancing of Powder coated extruded aluminium construction square shape return air diffusers with removable core, anti smudge ring & without volume control damper as per specifications.

5

-

-

... More
Supplying & fixing of opposed blade aluminium construction volume control dampers in supply air duct collars as per approved drawings and specifications.

8

-

-

... More
Supply, installation, testing and balancing of inlet air louvers with bird screen and volume damper for fresh air in powder coated extruded aluminium construction as per specifications and approved shop drawings.

2

-

-

... More
THERMAL INSULATION Supply, installation and testing of acoustic lining with 12 mm thick fiber glass rigid board in supply air ducts as per the specifications.

50

-

-

... More
Supply and fixing of UL approved thermal insulation on AC ducts with 13 mm thick closed cell Nitrile rubber Class O insulation including providing adhesive, adhesive tapes etc. as per specifications.

250

-

-

... More
Supply and fixing of UL approved thermal insulation as above, but 19mm thick coverd with 2 layers of Glass cloth soaked in star bond/equivalent UV Protection material as per direction of Engineer Incharge/ Consultant. In addtion the Insulation exposed to whether shall have 2 layers of Glass cloth soaked in star bond/equivalent UV Protection material as per direction of Engineer Incharge/ Consultant.

100

-

-

... More
Electrical work Scope of work shall include control panels, power / control cabling/ wiring/ GI earthing from Control Panel to various equipment and their starters like package chillers, Pumps, Hot water generators, AHUs Distribution Panel, etc along with GI strip connections. MAIN HVAC Panel: MCC-1 at plant room Designing, fabricating, transporting to site, installing, testing and commissioning of floor mounted, self supported, compartmentalized LT cubical pattern (Extendable Type) metal clad switch board, fabricated from 2mm (14 G) thick CRCA sheet steel suitable for 31 MVA rupturing capacity at 415 V, 3 phase, 4 wire, 50 HZ AC supply and equipped with PVC sleeved aluminum bus bars of specified rating and following switch gears inter connected by PVC sleeved solid conductors, including 7-tank cleaning, degreasing, phosphating process and treatment of panel with anti-corrosive zinc based primer paint and finally powder coating the panel, complete with earthing terminals, cable and bus bar alleys and hoisting hooks as required. The LT panel will comprise ACBs and MCCBs as described below for incoming and outgoing power supplies. INCOMERS 1 No 800 AMP MCCB OUTGOINGS :3 Nos. MCCB 800 Amp, 5 Nos. 40 amp MCCB, 1 Nos. MCCB 315 amp. (As per Sepecification DNIT Page No. 96-97)

1

-

-

... More
AHU Panel Type 1 ( OT1,2 and OT 3,4 and OT 5) Incoming 1 no.100 amp MCCB TPN . Phase indicating lights with control fuses. Breaker ON/OFF/TRIP indicating lights. Metering for incoming: 1 No. Voltmeter of range 0-500V, selector switch and 2 Amps SP MCB back up. One Nos. Ammeter of range 0-125 A, selector switch and 3 Nos. of associated CT's of ratio 63/5 A. 1 set of phase indicating lamps RYB with 2A,SP, MCB backup. Bus Bars100 amp TPN Aluminum BB with heat shrinkable insulation colored sleeves. Outgoings 1 nos TP MPCB, 20-25 A with DOL starter and VFD bypass for AHU Motor 1 Nos. 40 A TPN MCCB with ammeter, indication lamp with MCB for ‘ON’ status of equipment. Overload and under voltage protection device, Single phase preventer, phase reversal protection. For Pan Type Humidifier 1 Nos. 16 A TPN MCB indication lamp with MCB for ‘ON’ status of equipment. Overload and under voltage protection device, For Fumigation fan. 1 No. 10 amps DP MCB (single Phase) with step down transformer 220V to 24V (AC) Phase indicating lights with control fuses. Breaker ON/OFF/TRIP indicating lights. Each outgoing shall have auto/manual selector switch, indication lamps with control MCB's, ON/OFF push buttons, space for VFD and suitable ventilation for VFD, necessary internal control and power wiring in all respect. .The panel shall have necessary contactors / ancillaries for BMS operation and fire signal. Panel as described above and in drawings.

3

-

-

... More
AHU Panel Type 3 Incoming 1 no.63 amp MCCB TP Phase indicating lights with control fuses. Breaker ON/OFF/TRIP indicating lights. Metering for incoming: 1 No. Voltmeter of range 0-500V, selector switch and 2 Amps SP MCB back up. One Nos. Ammeter of range 0-63A, selector switch and 3 Nos. of associated CT's of ratio 63/5 A. 1 set of phase indicating lamps RYB with 2A,SP, MCB backup. Bus Bars 100 amp TPN Aluminum BB with heat shrinkable insulation colored sleeves. Outgoings 1 nos TP MPCB, 40 amp with DOL Starter 1 No. 10 amps DP MCB (single Phase) with step down transformer 220V to 24V (AC) Each outgoing shall have auto/manual selector switch, indication lamps with control MCB's, ON/OFF push buttons, necessary internal control and power wiring in all respect. .The panel shall have necessary contactors / ancillaries for BMS operation and fire signal. The base frame shall be 75 mm x 5 mm. Panel as described above.

3

-

-

... More
CONSOLE PANEL/AHU CONTROL CENTRE Console Centre shall have the control facility of all AHU`s/Fans with selection facility of Local/Remote, LED Indicators for ON, OFF, & Trip and ON , OFF Push Stations. Including HRC Fuse/MCB/Isolators rquired for smooth functioning of control centre. The Console Centre shall be able to control 23AHU`s/Fan`s having 2 in number spare control stations. (One control stations shall contain Selector switch - 1nos, ON/OFF push button - 1 Each, ON/OFF/Trip LED Indicator - 1Each) other accessories like cable manager etc. shall be treated as included. Complete in all respect

1

-

-

... More
Supply of HVAC dedicated VFDs with IP 55 enclosures with Mains disconnect, complying with the tender specifications and having: 1. Built-in dual 5% impedance DC link reactor (harmonic filters) on the positive and negative rails of the DC bus of the VFD. 2. Built-in EMC Filters (electromagnetic compatibility filters) for VFDs for restriction of conducted emissions to comply with IEC61800: 3 (unrestricted distribution):2004 Category C 3. 3. Three-feedback PID controller having capability to simultaneously accept 3 feedback signals from temperature sensors or pressure sensors for process optimization and accordingly regulate the speed of the AHUs. 4. Additional 3 PID controllers to control external devices such as chilled water modulating valve, fresh air damper, etc. thus reducing the number of I/Os in DDC Controllers & improving system reliability. 5. Automatic Energy Optimization / Load dependent flux optimization functionality for maximum energy savings. 6. MODBUS RTU as the communication protocol between BMS & VFDs. 7. VFDs not meeting above requirements shall provide external disconnect, external harmonic filters, additional external EMC Filters to comply with IEC61800: 3 (unrestricted distribution):2004 Category C 3, external PLCs / DDCs to achieve 3 Feedback PID Controller functionality and external devices controlling capabilities. 8. The VFD cost shall include suitable PID controller for regulating the flow of air by controlling the frequency of VFD. 5 HP

1

-

-

... More
7.5 HP

2

-

-

... More
Power Cabling: Supply, laying testing and commissioning of 1100 volt grade armored XLPE. insulated and sheathed aluminium/copper conductor cables of sizes as below, on cable trays with suitable clamps, saddles, hooks, bolts etc. complete as per specifications and as required. The quoted rate shall include the cost of proper dressing of cables and also providing identification tags as required. 3.5 core 150 Sq.mm Al cable

200

-

-

... More
3.5 core 35 Sq.mm Al cable

100

-

-

... More
3.5 core 25 Sq.mm Al cable

100

-

-

... More
4 core 16 Sq. mm Al cable

200

-

-

... More
4 core 10 Sq. mm Al cable

200

-

-

... More
4 core 6 Sq. mm Al cable

100

-

-

... More
4 core 4 Sq. mm Copper armoured

200

-

-

... More
4 C x 16 Sqmm Copper armoured

100

-

-

... More
3Cx2.5 Sqmm Copper armoured

400

-

-

... More
Supplying, installation, testing and commissioning of control cabling with insulated PVC sheathed wire/cable as per IS-7098 (Part-1) of following sizes including terminations on suitable cable trays / uPVC pipe with supports, as required including connections on both sides as per specifications and as required. 2 core x 1.5 sq. mm.

300

-

-

... More
3 core x 1.5 sq. mm.

400

-

-

... More
4 core x 1.5 sq. mm.

300

-

-

... More
6 core x 1.5 sq. mm.

200

-

-

... More
8 core x 1.5 sq. mm.

100

-

-

... More
12 core x 1.5 sq. mm.

100

-

-

... More
Cable Trays Supplying and installing following size of performated pre-painted MS cable trays cross members with perforation not more than 17.5% joined with connectors, suspended from the ceilling with MS suspenders including nuts , bolts, bends , reducers etc. painted suspenders etc. as required. 150mm (W) x 50mm (D) x 1.6mm thickness

80

-

-

... More
300mm (W) x 50mm (D) x 1.6mm thickness

80

-

-

... More
450mm (W) x 50mm (D) x 2.0mm thickness

50

-

-

... More
Earthing: Supply and fixing of GI earthing conductor of following sizes completely as required. 25 x 5 mm GI strip

150

-

-

... More
4 Swg Cu wire

250

-

-

... More
6 Swg Cu wire

400

-

-

... More
Supply of isolators for fan motor comprising of 32/63 amp MCB enclosed in weather proof MS casing

6

-

-

... More
Supplying and fixing of thermostat box for AHUs completely as required.

6

-

-

... More
Supplying and fixing 2000mm x 900mm x 12 mm thick checkered rubber matting conforming to IS- 5424-1969 complete etc. as required.

1

-

-

... More
PUFF PANELS FOR TEMPORARY PLANT ROOM Supply Installation, Testing and Commissioning of 100 mm thick PUF panels made up of minimum 0.60 mm thick Pre-painted G.I. sheet on both sides with tongue and groove arrangement and having internal cam locks for jointing. 'U' type flushing made of at least 20 G GI sheet shall be fixed on the foundation using secure foundation bolts throughout the edges of foundation. PUF panels shall be fixed inside the 'U' type flushings already fixed onto floor using rivets at suitable distance to form the walls of the AHU room. The jointing of panels should be internally cam locked type. The panels should have tongue and groove joints for proper fixing. At the joints of the panels on the outside and inside fix 50 mm wide flat strips made of 0.60 mm thick pre colour coated GI sheet so as to prevent any moisture ingress and leakage inside the panels. The PUF panels shall be minimum 50 mm thick with 0.6 mm thick PP GI sheet on both sides with tongue and groove arrangement having internal cam locks for jointing. The inside corner of panel walls corner angles made of 0.6 mm thick PPGI shall be fixed to cover the corner joints. Similarly external corner of PUF panels for walls and roof shall be fixed of 0.6 mm thick PP GI. The roof panels shall be further reinforced with hollow M.S. tubes to increase their load bearing capacity. 50 mm wide 'U' type flushing made of at least 20 G GI sheets shall be fixed on the edges of the roof using secure rivets to stop water entering into the panel. The roof panels will also have interlocking with cam locks and shall have a slope of 1: 50. All exposed foam panels will be covered with C type flushing. All joints are to be thoroughly filled with silicone sealant before covering the joints with flat joints. The rooms shall adequate openings duly sealed for cable, chilled water, and hot water and drain pipes. Provision shall be made in the AHU room for putting fresh air grill and the same will have adequate shelter to avoid ingress of water etc. Providing and fixing of 100 mm panel for walls in white alpine colour having tongue and groove joint with cam locks for interlocking the panels with all accessories as described above.

90

-

-

... More
Providing and fixing of 50 mm panel for Roof in white alpine colour having tongue and groove joint with cam locks for interlocking the panels with all accessories as described above.

40

-

-

... More
Providing and fixing of PUF panel door with door frame, door handle along with rubber gasket hinges etc and flushing as described above

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.