If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Baba Farid University Of Health Sciences - BFUHS Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date8 Nov 2024
Closing Date20 Nov 2024
Tender Amount₹ 12,69,679.07 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

  • EMD

    ₹ 25,500
  • Document Cost

    ₹ 1,180
  • Tender Fee

    ₹ 2,360

Summary

Replacing Damaged Roof Of 10 Nos. Garages Near Opd Parking Area Of Ggsmh, Fdk

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Replacing damaged roof of 10 Nos. Garages Near OPD Parking Area of GGSMH, FDK
Replacing damaged roof of 10 Nos. Garages Near OPD Parking Area of GGSMH, FDK
Financial bid for replacing damaged roof of 10 Nos. Garages Near OPD Parking Area of GGSMH, FDK
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Dismantling reinforced cement concrete work over roof

15.18

2321

35246.59

... More
Dismantling cement conglomerate floors 25mm to 50mm thick including concrete base.

83.84

114

9627.35

... More
Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres.

4.48

191

859

... More
Cement concrete 1:8:16 With brick ballast 40mm gauge mixing by mechanical means using concrete mixer volumetric type

9.47

3843

36394.54

... More
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth

1.83

5014

9176.26

... More
Damp proof course 4cm thick of cement concrete 1:2:4 with water proofing compound as per manufactures guidelines

1.05

257

269.9

... More
First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level.

12.89

5159

66509.05

... More
Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc

205.59

560

115224.97

... More
Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steelreinforcement centring and shuttering in superstructure including cost of mechanical mixer and vibrator

33.97

7182

244001.41

... More
Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete

29.89

7876

235440.84

... More
Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing

212.25

731

155250.26

... More
Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16

6

106

636.06

... More
Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 4 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge.

20.09

128

2582.17

... More
Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. UPVC 110 mm bend

6

142

853.32

... More
Plastering on underside of ceiling 10mm thick cement plaster 1:3

200.07

195

39097.68

... More
12.5 mm thick cement plaster 1:4 on walls

44.31

201

8916.06

... More
12.5 mm thick cement plaster 1:5 on walls

342.11

192

65955.39

... More
Cement concrete 1:2:4 With stone ballast or shingle using mechanical mixter

7.18

5653

40589.19

... More
Floating coat of 1.5 mm thick neat cement laid in one operation to the topping.

124.44

30

3801.64

... More
Supplying and fixing rolling shutters, of approved make, made of 80mmx1.25mm, M.S. Laths, interlocked together through their entire length and jointed together, at the end, by end locks, mounted on specially designed pipe shaft, with brackets, side guides, 27.5cm long wire spring grade No. 2 and arrangement for inside and outside locking with push and pull operation complete, including top cover 0.80mm thick (payment is to be made for the exact size of opening where rolling shutter is to be fixed

7.06

2946

20803.28

... More
Labour cost of rolling shutters, of approved make, made of 80mmx1.25mm, M.S. Laths, interlocked together through their entire length and jointed together, at the end, by end locks, mounted on specially designed pipe shaft, with brackets, side guides, 27.5cm long wire spring grade No. 2 and arrangement for inside and outside locking with push and pull operation complete,

70.61

400

28244

... More
scrapping of white wash and colour wash from the walls

643.6

7

4743.33

... More
White washing (two or more coat

763.08

11

8844.1

... More
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.

155.33

69

10800.09

... More
Cleanning of building rubbish from site to outside building rubbish lead 5 kms.

33.95

219

7444.9

... More
Recovery of old material at site. Bricks

950

4

-4085

... More
Brick tiles

2089

4

-9400.5

... More
Brick bats

6.77

472

-3198.83

... More
Scrap of erotten steel

454.4

32

-14540.8

... More
Electrical WorkRECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Supply & erection of Wiring fan point (With fan box)

14

1210

16942.8

... More
Supply & erection of wiring light point

32

762

24399.04

... More
Wiring 6Amp. Plug control comprising wall socket point RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES

14

371

5198.9

... More
Supply & erection of wiring 16Amp. Plug control comprising wall socket point RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES

14

478

6692.28

... More
Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge overall size 1.5 sq.mm (Un-sheathed)

190

24

4683.5

... More
Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge overall size 4 sq.mm (Un-sheathed)

295

53

15755.95

... More
Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications Heavy Gauge PVC Conduit Pipe 25mm dia. (On Surface)

125

57

7190

... More
Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs MCB Single Pole 6-32amp. (10kA, Curve-C

24

190

4573.68

... More
MCB Four Pole 50, 63amp. (10kA, Curve-C)

1

1750

1750.75

... More
Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-TP&N Vertical Double Door Distribution Board 8 way each

1

8518

8518.23

... More
Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:-MCCB Four Pole 125 amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting

1

9342

9342.01

... More
Supply and erection of High quality aluminium extruded with decorative end caps glazed LED batten of Make Jaquar Item Code LGLZ01x020XC or Its equilant Make and Cat. of Philips / Crompton including erection of the same with connections, testing etc.complete in all respects as approved and desired by the Engineer in-charge at site. (BFUHS/UWD/2019/10622 Dt 27/5/2019)

26

521

13546

... More
Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade to be laid (On Surface) as per PWD General Specifications Overall size 25sq.mm (4Core) Un-armoured (On-Surface)

20

193

3871.6

... More
Supply and erection of Ceiling Fan 1200mm (48") with double ball bearing including flexible wire & petty material etc. for connections and testing complete in all respects as approved and desired by the Engineer in-charge at site. Makes: Crompton High Speed Opel White, Anchor XL code14067 WH, Havell's Velocity HS

4

2201

8804

... More
Supply and erection of Heavy duty Exhaust Fans 300mm, 900RPM with aluminium louver shutter, double ball bearing longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site. Make: Crompton EXHD300-6-1, Havells Turbo Force SP, Anchor Anmol Heavy Duty BFUHS/UWD/2021/25524-30 Dt 20/12/2021

1

3501

3501



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.