Baba Farid University Of Health Sciences Tender
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 25,500Document Cost
₹ 1,180Tender Fee
₹ 2,360
Summary
Replacing Damaged Roof Of 10 Nos. Garages Near Opd Parking Area Of Ggsmh, Fdk
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_DMER_129572_1Tender No
BFUHS/169/2024Tender Authority
Baba Farid University Of Health Sciences ViewPurchaser Address
-Website
http://http://www.bfuhs.ac.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Replacing damaged roof of 10 Nos. Garages Near OPD Parking Area of GGSMH, FDK
Replacing damaged roof of 10 Nos. Garages Near OPD Parking Area of GGSMH, FDK
Financial bid for replacing damaged roof of 10 Nos. Garages Near OPD Parking Area of GGSMH, FDK
BOQ Items
Dismantling reinforced cement concrete work over roof
15.18
2321
35246.59
Dismantling cement conglomerate floors 25mm to 50mm thick including concrete base.
83.84
114
9627.35
Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres.
4.48
191
859
Cement concrete 1:8:16 With brick ballast 40mm gauge mixing by mechanical means using concrete mixer volumetric type
9.47
3843
36394.54
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth
1.83
5014
9176.26
Damp proof course 4cm thick of cement concrete 1:2:4 with water proofing compound as per manufactures guidelines
1.05
257
269.9
First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level.
12.89
5159
66509.05
Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc
205.59
560
115224.97
Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steelreinforcement centring and shuttering in
superstructure including cost of mechanical mixer and vibrator
33.97
7182
244001.41
Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete
29.89
7876
235440.84
Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing
212.25
731
155250.26
Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16
6
106
636.06
Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 4 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge.
20.09
128
2582.17
Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. UPVC 110 mm bend
6
142
853.32
Plastering on underside of ceiling 10mm thick cement plaster 1:3
200.07
195
39097.68
12.5 mm thick cement plaster 1:4 on walls
44.31
201
8916.06
12.5 mm thick cement plaster 1:5 on walls
342.11
192
65955.39
Cement concrete 1:2:4 With stone ballast or shingle using mechanical mixter
7.18
5653
40589.19
Floating coat of 1.5 mm thick neat cement laid in one operation to the topping.
124.44
30
3801.64
Supplying and fixing rolling shutters, of approved make, made of 80mmx1.25mm, M.S. Laths, interlocked together through their entire length and jointed together, at the end, by end locks, mounted on specially designed pipe shaft, with brackets, side guides, 27.5cm long wire spring grade No. 2 and arrangement for inside and outside locking with push and pull operation complete, including top cover 0.80mm thick (payment is to be made for the exact size of opening where rolling shutter is to be fixed
7.06
2946
20803.28
Labour cost of rolling shutters, of approved make, made of 80mmx1.25mm, M.S. Laths, interlocked together through their entire length and jointed together, at the end, by end locks, mounted on specially designed pipe shaft, with brackets, side guides, 27.5cm long wire spring grade No. 2 and arrangement for inside and outside locking with push and pull operation complete,
70.61
400
28244
scrapping of white wash and colour wash from the walls
643.6
7
4743.33
White washing (two or more coat
763.08
11
8844.1
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
155.33
69
10800.09
Cleanning of building rubbish from site to outside building rubbish lead 5 kms.
33.95
219
7444.9
Recovery of old material at site. Bricks
950
4
-4085
Brick tiles
2089
4
-9400.5
Brick bats
6.77
472
-3198.83
Scrap of erotten steel
454.4
32
-14540.8
Electrical WorkRECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Supply & erection of Wiring fan point (With fan box)
14
1210
16942.8
Supply & erection of wiring light point
32
762
24399.04
Wiring 6Amp. Plug control comprising wall socket point RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES
14
371
5198.9
Supply & erection of wiring 16Amp. Plug control comprising wall socket point RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES
14
478
6692.28
Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge overall size 1.5 sq.mm (Un-sheathed)
190
24
4683.5
Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge overall size 4 sq.mm (Un-sheathed)
295
53
15755.95
Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications Heavy Gauge PVC Conduit Pipe 25mm dia. (On Surface)
125
57
7190
Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs MCB Single Pole 6-32amp. (10kA, Curve-C
24
190
4573.68
MCB Four Pole 50, 63amp. (10kA, Curve-C)
1
1750
1750.75
Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-TP&N Vertical Double Door Distribution Board 8 way each
1
8518
8518.23
Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:-MCCB Four Pole 125 amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting
1
9342
9342.01
Supply and erection of High quality aluminium extruded with decorative end caps glazed LED batten of Make Jaquar Item Code LGLZ01x020XC or Its equilant Make and Cat. of Philips / Crompton including erection of the same with connections, testing etc.complete in all respects as approved and desired by the Engineer in-charge at site. (BFUHS/UWD/2019/10622 Dt 27/5/2019)
26
521
13546
Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade to be laid (On Surface) as per PWD General Specifications Overall size 25sq.mm (4Core) Un-armoured (On-Surface)
20
193
3871.6
Supply and erection of Ceiling Fan 1200mm (48") with double ball bearing including flexible wire & petty material etc. for connections and testing complete in all respects as approved and desired by the Engineer in-charge at site. Makes: Crompton High Speed Opel White, Anchor XL code14067 WH, Havell's Velocity HS
4
2201
8804
Supply and erection of Heavy duty Exhaust Fans 300mm, 900RPM with aluminium louver shutter, double ball bearing longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site. Make: Crompton EXHD300-6-1, Havells Turbo Force SP, Anchor Anmol Heavy Duty BFUHS/UWD/2021/25524-30 Dt 20/12/2021
1
3501
3501
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%