Baba Farid University Of Health Sciences Tender

... More
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Baba Farid University Of Health Sciences - BFUHS Tender

Works
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date15 Jan 2025
Closing DateCancelled
Tender Amount₹ 6,30,60,044.73 
This is an estimated amount, exact amount may vary.
Notes
Download

AI Insights

Class Of Bidder
... View More
The class eligibility requirement to bid or participate in this tender is registration of contractor of appropriate class, but the specific class is not mentioned.
Bid Capacity
... View More
To extract the bid capacity required, we look at the provided formula and values. The formula given is: Assessed Available Bid Capacity = (A * N * 2 - B), where A is the maximum value of civil engineering works executed in any one year during the last five years, N is the number of years prescribed for completion of the project, and B is the value of existing commitments and ongoing works. Given the cost of the work is Rs. 6,30,60,045.00, and the requirements for similar works are either two works of 50% of this value or one work of 80% of this value, we calculate these as Rs. 3,15,30,022.50 for two similar works and Rs. 5,04,48,036.00 for one similar work. However, without specific details on A, N, and B for the bidder, we cannot directly calculate the Assessed Available Bid Capacity using the provided formula. The values of A, N, and B are crucial for determining the bid capacity, and without them, we cannot proceed with the calculation. Therefore, the bid capacity required in terms of a specific value or formula directly applicable to the given tender cannot be accurately determined with the information provided.
Technical Capacity
... View More
The required prior work experience for the bidder is related to the "Assessed Available Bid Capacity" calculation, which involves the maximum value of Civil Engineering works executed in any one year during the last five years. The bidder needs to provide details of their available bid capacity, which should be more than the total value of their financial bid for works above Rs. 1.00 Crore. For electrical work, the minimum required experience includes: - 80% value of one similar work, which is Rs. 50448036.00 - 50% value of two similar works, which is Rs. 31530023.00 These values indicate the minimum amount of similar work experience required for a bidder to be eligible. The calculation of Assessed Available Bid Capacity also involves the number of years prescribed for completion of the Project/Works and the value of existing commitments and on-going works. The formula for calculating the Assessed Available Bid Capacity is: (A * N * 2 - B), where A is the maximum value of Civil Engineering works executed, N is the number of years for completion, and B is the value of existing commitments and on-going works.

Costs

  • EMD

    ₹ 12,62,000
  • Document Cost

    ₹ 5,900
  • Tender Fee

    ₹ 5,900

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
PROVIDING 11KV SUBSTATION INCLUDING DG SET, TRANSFORMER AND ELECTRICAL WORK
PROVIDING 11KV SUBSTATION INCLUDING DG SET, TRANSFORMER AND ELECTRICAL WORK
FINANCIAL BID FOR PROVIDING 11KV SUBSTATION INCLUDING DG SET, TRANSFORMER AND ELECTRICAL WORK
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
VACUUM CIRCUIT BREAKER: IN SUBSTATION FOR 2NOS. TRANSFORMERS 1250 & 1600KVA Supply, Erection, Testing and Commisioning of 11kV, 3Phase, 50Hz, Indoor metal clad, floor mounted, ‘Horizontal draw out’ type VCB (Vacuum Circuit Breaker) switch board unit 630 Amp. which includes 630/800 Amp. Vacuum Circuit Breaker for Incoming/ Out going feeder with Electrolytic Copper bus bars of suitable rating, Horizontal Isolation type as per IEC 62271-100-200. The Switchgear panels shall be sheet steel construction with ALUZINC not less than 2.5mm thickness for load bearing sections and not less than 2mm thickness for non-load bearing, dust, moisture and vermin proof to provide a degree of protection IP-4X in accordance with IS:13947. VCBs are type tested according to International Standards IEC-62271 at renowned laboratories. They are compact, safe and reliable. The Panels shall be tested for IAC level of 25kA/1 Sec. No. of operations of Vacuum interrupter bottles for better performance (i) At rated current: 10,000 operation (ii) No. of short circuit dead operation at rated short circuit current: 100 opeartion

-

-

-

... More
VCB parameters are as below: (a). Rated Voltage: 12kV (b). Rated short circuit breaking current withstand : Min. 25kA for 3sec. (c). Rated insulation voltage lightning (Impulse withstand) : At 75kV Peak (d). Rated insulation voltage( Power frequency withstand) : Min. 28kV (e). Rated operating sequence : O-0.3 sec - CO - 3 min-CO (f). Spring charging mechanism : Manually as well as motor operated (230V, AC, 50Hz) (g). Operation type: Manually and electrically open (Electrical-230V, AC,50Hz) (h). Earthing Switch : Mechanically interlocked device to prevent personnel from getting electric shock during breaker maintenance. VCB incorporating mechanical as well as electrical ON/OFF indiaction "OFF" push button, test/ serviceposition limit switches, with minimum 6NO+6NC breaker auxiliary contacts in service position, Manual charging of breaker should be done without opening the front door.

-

-

-

... More
Incomer shall consist of: (a). Cast Resin CT's 11kV : 600-300/1-1A, Core1: Class1, 10VA for 3phase, Core2: 5P10, 10VA (b). Cast Resin PT's 11kV : PT Ratio 11kV/√3 / 110V/√3 / 110V/√3, Class 1, Class 0.5 Burden 50VA (c). Protections : Numerical instantaneous IDMTL mimic dispaly relay (230V, AC, 50Hz) : U/V, O/V, E/F, O/C, S/C & TCS with RS 485 Modbus protocol for communication & drawout type (d). Master Trip/ Anti pumping relay (e). Digital Voltmeter : Range 0-12kV with necessary voltmeter with built in selector switch & suitable for 230V AC 96x96 sq.mm dial with shrouded terminal. (f). Digital Ammeter : Applicable Range with necessary ammeter with built in selector switch & suitable for 230V AC 96x96 sq.mm dial with shrouded terminal. (g). Multi-function meter with suitable communication to Central Software dta control & SCADA system, Converter having facility of real time data monitoring, historical trend and web dashboard (h). Necessary AC supply, healthy indication lamp & switch, TNC (Trip, Neutral & Close) breaker control switch with indicating arrangement, Local/ remote selector switch for breaker open/close operations All the relays shall belong to a common platform and shall be of single make with Electro-mechanical type relays in draw-out casing. PCB shall be with conformal coating to withstand heavily polluted environments.

-

-

-

... More
Outgoing shall consist of: (a). Cast Resin CT's 11kV : 600-300/1-1A, Core1: Class1, 10VA for 3phase, Core2: 5P10, 10VA (b). Protections : Numerical instantaneous IDMTL mimic dispaly relay : E/F, O/C, S/C & TCS with RS485 Modbus protocol for communication & drawout type for line feeder protection (c). Master Trip/ Anti pumping relay (d). Transformer Protection : 3 elements auxiliary relay (230V, AC, 50Hz) for transformer fault, Alarm for Buchholz, winding temperature & oil temperature (e). Digital Ammeter : Applicable Range with necessary ammeter with built in selector switch & suitable for 110V AC 96x96 sq.mm dial with shroded terminal (f). Multi-function meter with suitable communication to Central Software dta control & SCADA system, Converter having facility of real time data monitoring, historical trend and web dashboard (g). Necessary AC supply, healthy indication lamp & switch, TNC (Trip, Neutral & Close) breaker control switch with indicating arrangement, Local/ remote selector switch for breaker open/close operations All the relays shall belong to a common platform and shall be of single make with Electro-mechanical type relays in draw-out casing. PCB shall be with conformal coating to withstand heavily polluted environments:- 11kV, 3Phase, 50Hz, Indoor metal clad, floor mounted, ‘Horizontal draw out’ type VCB (Vacuum Circuit Breaker) Switch board unit 630 Amp. which includes 1 No. 630 /800Amp. Vacuum Circuit Breaker as Incomer, 2Nos. Vacuum Circuit Breaker as Out going feeder with in built power packs interconnected with Electrolytic Copper bus bars of suitable rating (2Nos. 800 KVA Transformer).

1

1794617

1794617

... More
TRANSFORMER 1250KVA: Supply, installation, testing and commissioning of 11KV/433V, 1250KVA, Indoor/Outdoor type floor mounted Distribution Transformer, Three Phase 50 Hz, Oil Immersed, Naturally Cooled ONAN, Core type Double wound with copper conductor conforming to IS:1180 (As amended upto date) Level-2 & IS: 2026 with first filling of Oil as per IS:335 compltete with connections on both sides (HT/LT side) as per satisfaction of Engineer Incharge at site. (a). Output Rating : KVA (b). No Load Voltage ratio at rated voltage & frequency: 11KV/ 0.433kV (c). Off Circuit Tap changer: +5% to -10% off circuit tapping in steps of 2.5%. (d). Vector group : Dyn11 (e). Ambient temperature: 50°C (f). Oil/ Winding temperature rise: As per IS:1180 (g). Magnetic Core: Prime grade of M4 or better (h). System Highest Voltage :- 12kV at the HV side (i). Terminations: Cable Box on HV & LV Side (j). Insulation Level: ● H.V. Power Frequency (KV rms) : 28 kV ● H.V. Impulse withstand voltage (KV peak): 75 kVp The Tranformers shall fitted with accesories like Rating and Diagram anodized aluminium plate, 2 Nos. Earthing terminals, 4 Nos. Lifting Lugs, Air Release hole with plug, Dehydrating Silica Gel Breather, Oil Level guage with minimum level marking, Conservator with Oil filling hole with cap & drain plug, Thermometer Pocket, Jacking Lugs, Bottom Drain cum filter valve, Top Filter Valve, 4Nos. Uni-directional rollers, Explosion vent with diaphragm, Marshmalling Box (Protection Class IP55), OTI with alarm & trip, WTI with alarm & trip, Double float Buchholz relay with alarm & trip, 2Nos. Shunt off valves for Buchholz relay & Fixed/ Detachable Radiator. Note: Manufacturer testing labotatory to be NABL certified with in house core cutting facility for proper control & monitoring of quality & to avoid mixing of Prime core with Second grade /defective core materials. Transformer designed for 110% continuous overfluxing withstand capability as per IS:6600. Noise Level for Transformer shall be as per NEMA TR1-2013. All Routine Test shall be carried out as per IS: 2026:-

1

3069282

3069282

... More
TRANSFORMER 1600KVA: Supply, installation, testing and commissioning of 11KV/433V, 1600KVA, Indoor/Outdoor type floor mounted Distribution Transformer, Three Phase 50 Hz, Oil Immersed, Naturally Cooled ONAN, Core type Double wound with copper conductor conforming to IS:1180 (As amended upto date) Level-2 & IS: 2026 with first filling of Oil as per IS:335 compltete with connections on both sides (HT/LT side) as per satisfaction of Engineer Incharge at site. (a). Output Rating : KVA (b). No Load Voltage ratio at rated voltage & frequency: 11KV/ 0.433kV (c). Off Circuit Tap changer: +5% to -10% off circuit tapping in steps of 2.5%. (d). Vector group : Dyn11 (e). Ambient temperature: 50°C (f). Oil/ Winding temperature rise: As per IS:1180 (g). Magnetic Core: Prime grade of M4 or better (h). System Highest Voltage :- 12kV at the HV side (i). Terminations: Cable Box on HV & LV Side (j). Insulation Level: ● H.V. Power Frequency (KV rms) : 28 kV ● H.V. Impulse withstand voltage (KV peak): 75 kVp The Tranformers shall fitted with accesories like Rating and Diagram anodized aluminium plate, 2 Nos. Earthing terminals, 4 Nos. Lifting Lugs, Air Release hole with plug, Dehydrating Silica Gel Breather, Oil Level guage with minimum level marking, Conservator with Oil filling hole with cap & drain plug, Thermometer Pocket, Jacking Lugs, Bottom Drain cum filter valve, Top Filter Valve, 4Nos. Uni-directional rollers, Explosion vent with diaphragm, Marshmalling Box (Protection Class IP55), OTI with alarm & trip, WTI with alarm & trip, Double float Buchholz relay with alarm & trip, 2Nos. Shunt off valves for Buchholz relay & Fixed/ Detachable Radiator. Note: Manufacturer testing labotatory to be NABL certified with in house core cutting facility for proper control & monitoring of quality & to avoid mixing of Prime core with Second grade /defective core materials. Transformer designed for 110% continuous overfluxing withstand capability as per IS:6600. Noise Level for Transformer shall be as per NEMA TR1-2013. All Routine Test shall be carried out as per IS: 2026:-

1

3569788

3569788

... More
APFC FOR 1250KVA TRANSFORMER: Design, supply, installation, testing and commissioning of APFC Panel of 400KVAR capacity with 7% detuned reactor suitable for operation on 415 ± 5% Volt, 3 Phase, 50 Hz, Ac supply, having MPP type resin bounded static capacitors (without oil) of suitable rating complete with MCCB Four Pole 630amp., 415volts, ≥36kA Microprocessor Based Adjustable Thermal and Magnetic Setting (Ics = 100%) capacity panel, upto 12 step microprocessor based power factor controller relay capable to select the rating from 2Nos. x 10KVAR, 2Nos. x 15KVAR, 2Nos. x 25KVAR 6Nos. x 50KVAR capcitor bank, current limiting contactors for each capacitors protected with suitable rating MCCBs of minimum 25 KA breaking capacity having thermal magnetic release for over load & short circuit protection, cooling fans for panel and digital multifunction meter, Class-1.0 with RS485 communication port indicating lights, earthing the panel etc. as reqd. The panel should have provision of timer based circuit in APFC relay to switch ON and OFF the static part of 120 KVAR capacity, automatically as and when required. Capacity of static capacitor should be accommodated from the overall rating of the panel and should be designed to switch in independently. The panel should be manufactured with1.6 mm thick CRCA sheet duly powder coated etc complete as per PWD specification complete as per satisfaction of the Engineer in charge at site.

1

827979

827979

... More
APFC FOR 1600KVA TRANSFORMER: Design, supply, installation, testing and commissioning of APFC Panel of 550 KVAR capacity with 7% detuned reactor suitable for operation on 415 ± 5% Volt, 3 Phase, 50 Hz, Ac supply, having MPP type resin bounded static capacitors (without oil) of suitable rating complete with 1000 A, 50kA , 4 Pole, ACB EDO capacity panel, 12 step microprocessor based power factor controller relay capable to select the rating from 2No. x 25KVAR, 10Nos. x 50KVAR capcitor bank, current limiting contactors for each capacitors protected with suitable rating MCCBs of minimum 25 KA breaking capacity having thermal magnetic release for over load & short circuit protection, cooling fans for panel and digital multifunction meter, Class-1.0 with RS485 communication port indicating lights, earthing the panel etc. as reqd. The panel should have provision of timer based circuit in APFC relay to switch ON and OFF the static part of 550 KVAR capacity, automatically as and when required. Capacity of static capacitor should be accommodated from the overall rating of the panel and should be designed to switch in independently. The panel should be manufactured with1.6 mm thick CRCA sheet duly powder coated etc complete as per PWD specification complete as per satisfaction of the Engineer in charge at site.

1

1451000

1451000

... More
INDOOR MAIN LT PANELS : Designing, Supply, Erection, Testing & commissioning of Indoor Type Tested LT cubical panel as per IEC 61439 standard enclosure (dust, vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system. The assembly manufacture should be ISO approved and CPRI tested for short circuit of (minimum 50kA) as well as IP degree of protection (IP44). Fabrication: Panel shall be made from 14/16 SWG CRCA sheet, conforming to IS:8623. The fabrication should be such that all the member i.e. vertical/horizontal should be detachable type i.e. total bolted. In case of any changes required at site should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar channel as well as the cable chamber should be totally isolated from the feeder chamber. Where the crossing of the wire or bus link should have proper rubber gourmets or non-hygroscopic material. No live part should be in visible condition. The base channel will be made out of 75mm x 40mm x 5mm rolled channel. "The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The panel door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. Minimum depth 400mm / wide 300 mm for busbar/ Cable ally at the front of the panel. The panel will be free standing floor mounting type having provision for cable entry from bottom/top with cable glands etc.

-

-

-

... More
Painting: The sheet metal is sprayed with corrosion resistant etch Primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work. Busbars: The Panel shall be provided with TPN Alumium busbar of suitable size according to the size of MCCB's. All Busbar will be air insulated with codified in Red, Yellow, Blue & Black as per standard for cable termination with the help of extended busbar only with proper adjustable cable supports. The main busbar would be supported upon non-hygroscopic SMC/DMC supports. Metering: The panel shall be completed with digital metering unit (with selector switches, voltmeter & ammeter) epoxy insulator, gasket, PVC sleeves, CT's & L.E.D. type indicator etc. Manufacturer of Panel should be CPRI Approved (Approval not older then 5 years) & ISO certified (Manufacturer workshop as per ISO 9001: 2015 standard). The Concerned contactor shall be approved the detailed drawing of panel with complete specification from the Engineer in charge at site. Detail of capacities of ACB/MCCB's to be installed in the cubical panel Enclosure (including the cost of MCCB's+E.R.H.) as per following.

-

-

-

... More
BLOCK-B: Transformer 1600KVA: Main Incomer: 2500 Amp.415volts 50KA,, 4P EDO ACB with M.P. Release ET6G Trip unit with O/L, S/C, E/F Prot = 1No. (From Transformer-1, 1600KVA) Under Voltage Release 220VAC for ACB Interlocking 2500 Amp.415volts 50KA,, 4P EDO ACB with M.P. Release ET6G Trip unit with O/L, S/C, E/F Prot = 1No. (From DG Synchronize Panel ACB 2500Amp.) Under Voltage Release 220VAC for ACB Interlocking INTERLOCKING: Both incomer and Buscoupler electricaly interlocked at a time two breaker can be operate. (Electrically & Mechanical Interlocked) Outgoings from Transformer-1, 1600KVA.: ■ 800 Amp.415volts 50KA, 4P EDO ACB with M.P. Release ET6G Trip unit with O/L, S/C, E/F Prot = 1No.■ 630amp. 415 volts breaking capacity ≥36kA, FP microprocessor based adjustable thermal and magnetic protection MCCB unit = 8Nos. Buscoupler:2500 Amp.415volts 50KA,, 4P EDO ACB with M.P. Release ET6G Trip unit with O/L, S/C, E/F Prot = 1No.Under Voltage Release 220VAC for ACB Interlocking BLOCK-A: Transformer 1250KVA: Main Incomer:2000 Amp.415volts 50KA,, 4P EDO ACB with M.P. Release ET6G Trip unit with O/L, S/C, E/F Prot = 1No. (From Transformer-1, 1250KVA) Under Voltage Release 220VAC for ACB Interlocking 2000 Amp.415volts 50KA,, 4P EDO ACB = 1No. (From DG Synchronize Panel ACB 2000Amp.)Under Voltage Release 220VAC for ACB InterlockingOutgoings from Transformer-2, 1250KVA :■ 630amp. 415 volts breaking capacity ≥36kA, FP microprocessor based adjustable thermal and magnetic protection MCCB unit = 7Nos .■ All Incomers & Out going With Extendable Rotary Handle with adjustable depth complete as per schematic diagram attached & Satisfaction of the Engineer in charge at site. Enclosure: Panel Size: As per Norms

1

3744100

3744100

... More
SYNCHRONISING PANEL: (DG SET SYNCHRONISING & LOAD SHARING PANEL) Designing, Supply, Erection, Testing & commissioning of Indoor Type Tested Synchronizing Panel (SYNCHRONIZING & LOAD SHARING PANEL) as per IEC 61439 standard suitable for 4Nos. DG Set capacity 320 KVA, 650KVA, 750 & 1010KVA enclosure (dust, vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system. The assembly manufacture should be ISO approved and CPRI tested for short circuit of (minimum 50kA) as well as IP degree of protection (IP44). Fabrication: Panel shall be made from 14/16 SWG CRCA sheet, conforming to IS:8623. The fabrication should be such that all the member i.e. vertical/horizontal should be detachable type i.e. total bolted. In case of any changes required at site should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar channel as well as the cable chamber should be totally isolated from the feeder chamber. Where the crossing of the wire or bus link should have proper rubber gourmets or non-hygroscopic material. No live part should be in visible condition. The base channel will be made out of 75mm x 40mm x 5mm rolled channel. "The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The panel door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. Minimum depth 400mm / wide 300 mm for busbar/ Cable ally at the front of the panel. The panel will be free standing floor mounting type having provision for cable entry from bottom/top with cable glands etc.

-

-

-

... More
Painting: The sheet metal is sprayed with corrosion resistant etch Primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work. Busbars: The panel shall be provided with TPN copper busbar of suitable size according to the size of MCCB's. All Busbar will be air insulated with codified in Red, Yellow, Blue & Black as per standard for cable termination with the help of extended busbar only with proper adjustable cable supports. The main busbar would be supported upon non-hygroscopic SMC/DMC supports. Metering: The panel shall be completed with digital metering unit (with selector switches, voltmeter & ammeter) epoxy insulator, gasket, PVC sleeves, CT's & L.E.D. type indicator etc. Manufacturer of Panel should be CPRI Approved (Approval not older then 5 years) & ISO certified (Manufacturer workshop as per ISO 9001: 2015 standard). The Concerned contactor shall be approved the detailed drawing of panel with complete specification from the Engineer in charge at site. Detail of capacities of ACB/MCCB's to be installed in the cubical panel Enclosure (including the cost of MCCB's+E.R.H.) as per following.

-

-

-

... More
Synchronization Relay having Protection, Auto Synchronization, Auto Load Management, Auto Load Sharing and Auto Changeover Feature Detailed Inbuilt Feature in Syn. Relay : Short-circuit, Over-current, Voltage-dependent over-current, Overvoltage, undervoltage, Overfrequency, underfrequency, Unbalanced voltage, Unbalanced current, Underexcitation, Overexcitation or Var import, Overload, Busbar/Mains O/V, Busbar/Mains Undervoltage, Busbar/Mains Overfrequency, Busbar/Mains Unbalanced Voltage, Emergency StopBusbar/Mains Underfrequency, Over-speed, Low-High Battery Voltage, Generator Breaker External Trip, Mains Breaker External Trip, GB Synchronisation Failure, GB Open Failure, MB Synchronisation Failure, MB Open-Close Failure, Phase Sequence Error, Hz/V Failure, Fuel fill check error, EIC warning via J1939/comm. link, EIC Coolant temperature via J1939/comm. link, EIC oil pressure via J1939/comm. link

-

-

-

... More
Synchronizing Panel (SYNCHRONIZING & LOAD SHARING PANEL) suitable for 4Nos. DG Set capacity 320 KVA, 650KVA, 750KVA & 1010KVA: Incomer Feeder From DG-1 (1010 KVA): ■ 1600A 4P 50KA EDO ACB with M.P. Release ET6G Trip unit with O/L, S/C, E/F Prot = 1No. Incomer Feeder From DG-2 (650 KVA): ■ 1000A 4P 50KA EDO ACB with M.P. Release ET6G Trip unit with O/L, S/C, E/F Prot = 1No.Incomer Feeder From DG-3 (750 KVA): ■ 1600A 4P 50KA EDO ACB with M.P. Release ET6G Trip unit with O/L, S/C, E/F Prot = 1No.Incomer Feeder From DG-4 (320 KVA): ■ 800A 4P 50KA EDO ACB with M.P. Release ET6G Trip unit with O/L, S/C, E/F Prot = 1No.Bus Coupler: ■ 4000A 4P 50KA EDO ACB with M.P. Release ET6G Trip unit with O/L, S/C, E/F Prot = 1No.Outgoings Feeders: ■ 2500A 4P 50KA EDO ACB with M.P. Release ET6G Trip unit with O/L, S/C, E/F Prot = 1No.■ 2000A 4P 50KA EDO ACB with M.P. Release ET6G Trip unit with O/L, S/C, E/F Prot = 1No.■ All Incomers & Out going With Extendable Rotary Handle with adjustable depth complete as per schematic diagram attached & Satisfaction of the Engineer in charge at site. Enclosure: Panel Size: As per Norms

1

4085100

4085100

... More
HT CABLE, END TERMINATION KITS & CONTROL CABLE FOR TRANSFOMER: XLPE INSULATED HT ARMOURED CABLES (UNDERGROUND): Supply & laying of Circular Aluminium Conductor screened with extruded semiconducting compound, XLPE insulated, insulation screened with extruded semiconducting combination in combination with copper tape (0.3KA for 1sec.) cores laid up, FR PVC inner sheathed, galvanized steel strip armoured and overall FR PVC sheathed cable confirming to IS:7098 (Part-2), 2011 working voltage 11KV(E) grade to be laid 1.50 meter below ground level including excavation, sand cushioning, covering with sand & First class bricks and back filling the trench etc., of the required size:- HT Cable Overall size 300sq.mm (3Core) (From PSPCL Meter to Metering Room VCB & Metering Room VCB to Substation Room VCB's)

250

2295

573947.5

... More
XLPE INSULATED HT ARMOURED CABLES (LOOSE): Supply & laying of Circular Aluminium Conductor screened with extruded semiconducting compound, XLPE insulated, insulation screened with extruded semiconducting combination in combination with copper tape (0.3KA for 1sec.) cores laid up, FR PVC inner sheathed, galvanized steel strip armoured and overall FR PVC sheathed cable confirming to IS:7098 (Part-2), 2011 working voltage 11KV(E) grade to be laid 1.50 meter below ground level including excavation, sand cushioning, covering with sand & First class bricks and back filling the trench etc., of the required size:- HT Cable Overall size 300sq.mm (3Core) (From PSPCL Meter to Metering Room VCB & Metering Room VCB to Substation Room VCB's)

50

1860

93045

... More
HT Cable Overall size 185sq.mm (3Core) (From Substation Room VCB's to Transformer 1600KVA)

100

1336

133626

... More
HT Cable Overall size 150sq.mm (3Core) (From PSPCL Meter to Metering Room VCB & Metering Room VCB to Substation Room VCB)

100

1154

115421

... More
S/E of Heat shrinkable cable end termination/ Straight through joint kit for 11 KVA /6.6 KV (E) XLPE Cables as approved & desired by Enginer in charge:- Heat Shrinkable End Termination for cable size 240-400 sq. mm, 3Core (Indoor Type)

4

4635

18542.44

... More
Heat Shrinkable End Termination for cable size 240-400 sq. mm, 3Core (Outdoor Type)

1

5473

5473.35

... More
Heat Shrinkable End Termination for cable size 120-185 sq. mm, 3Core (Outdoor Type)

4

4594

18377.24

... More
PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE: Supply and erection of XLPE/ PVC insulated PVC sheathed (10 core) unarmoured copper conductor cable (ISI marked) confirm to IS:7098 (PART-I), 1988 loose in the existing trench or pipe with suitable size of copper thimbles/ lugs complete in all respect as desired by the Engineer-in-charge:- (From Substation VCB to 2Nos. Transformers 1600 & 1250KVA) Overall size 2.5sq.mm (10 Core)

300

353

106002

... More
SANDWICH TYPE ALUMINIUM BUS BAR TRUNKING: (FROM TRANSFOMERS TO MAIN LT PANEL, APFC PANEL & MAIN LT PANEL TO SYNCH. PANEL) Supply, Installing testing and commissioning of 800A, 3P + 100% Neutral, 50KA For 1 Sec, Sandwich Bus trunking Straight Feeder Length, Aluminium Conductor, IP 55 with GI Enclosure in 1.5mm Thick. continuous earthing with 2 Nos integral earth conductor and Suspension Hanging system etc along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.

40

14911

596440

... More
Supply, Installing testing and commissioning of 2000A, 3P + 100% Neutral, 50KA For 1 Sec, Sandwich Bus trunking Straight Feeder Length, Aluminium Conductor, IP 55 with GI Enclosure in 1.5mm Thick. continuous earthing with 2 Nos integral earth conductor and Suspension Hanging system etc along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.

40

30830

1233200

... More
Supply, Installing testing and commissioning of 2500A, 3P + 100% Neutral, 50KA For 1 Sec, Sandwich Bus trunking Straight Feeder Length, Aluminium Conductor, IP 55 with GI Enclosure in 1.5mm Thick. continuous earthing with 2 Nos integral earth conductor and Suspension Hanging system etc along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.

40

34531

1381240

... More
Supply, Installing, testing & commissioning of Elbow vertical /Horizontal /off set Bend 800Amp / 3P+1N+E (Only fabrication charges) etc.along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.

8

10107

80856

... More
Supply, Installing, testing & commissioning of Elbow vertical /Horizontal /off set Bend 2000Amp / 3P+1N+E (Only fabrication charges) etc.along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.

8

14313

114504

... More
Supply, Installing, testing & commissioning of Elbow vertical /Horizontal /off set Bend 2500Amp / 3P+1N+E (Only fabrication charges) etc.along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.

8

16850

134800

... More
Supply, Installing Flange End Unit 800 Amp (Fabrication Charges only) complete with hardware-nuts and bolts etc.along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.

4

17447

69788

... More
Supply, Installing Flange End Unit 2000 Amp (Fabrication Charges only) complete with hardware-nuts and bolts etc.along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.

4

25798

103192

... More
Supply, Installing Flange End Unit 2500 Amp (Fabrication Charges only) complete with hardware-nuts and bolts etc.along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.

4

33532

134128

... More
Supply, installation, Copper Flexible 800Amp (1 Set of 4Nos. Copper Flexible) complete with hardware-nuts and bolts etc.along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.

4

23537

94148

... More
Supply, installation, Copper Flexible 2000Amp (1 Set of 4Nos. Copper Flexible) complete with hardware-nuts and bolts etc.along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.

4

62750

251000

... More
Supply, installation, Copper Flexible 2500Amp (1 Set of 4Nos. Copper Flexible) complete with hardware-nuts and bolts etc.along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.

4

87615

350460

... More
Supply, installation, of Adopter Box/tap off box for Transformer side and panel side 800 Amp. etc.along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.

4

31808

127232

... More
Supply, installation, of Adopter Box/tap off box for Transformer side and panel side 2000 Amp. etc.along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.

4

45424

181696

... More
Supply, installation, of Adopter Box/tap off box for Transformer side and panel side 2500 Amp. etc.along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.

4

52170

208680

... More
INDOOR LT CABLES, CABLE TRAY & DWC PIPE: XLPE INSULATED UN-ARMOURED CABLES (LOOSE):- Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- Overall size 16sq.mm (4Core) Un-armoured (Loose)

700

131

92183

... More
Overall size 120sq.mm (3½ Core) Un-armoured (Loose)

750

586

439507.5

... More
Overall size 185sq.mm (3½ Core) Un-armoured (Loose)

900

865

778671

... More
Overall size 240sq.mm (3½ Core) Un-armoured (Loose)

300

1114

334224

... More
Overall size 300sq.mm (3½ Core) Un-armoured (Loose)

300

1355

406518

... More
DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- Double walled corrugated (DWC) HDPE pipe 63/51 mm (outer/ inner dia.)

620

155

96670.4

... More
Double Walled Corrugated HDPE Pipe 90/76mm (Outer/ Inner dia.)

50

199

9955.5

... More
Double walled corrugated (DWC) HDPE pipe120/103.50mm (outer/ inner dia.)

670

290

194815.9

... More
Double Walled Corrugated HDPE Pipe 160/ 136mm (Outer/ Inner dia.)

720

341

245757.6

... More
Double Walled Corrugated HDPE Pipe 180/152mm (Outer/ Inner dia.)

540

426

230401.8

... More
CABLE TRAY: Supply and erection of MS perforated cable tray (MS Sheet thickness 2mm) with DA gray paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x 6mm thick to be fixed with fastners/ nut & bolts etc., complete in all respect as desired by the Engineer-in-charge and as per PWD General Specifications:- Cable Tray Size 300mm x 50mm x 50mm (2mm thick)

20

1455

29114.6

... More
Cable Tray Size 450mm x 50mm x 50mm (2mm thick)

20

1902

38052.4

... More
S/E of LT Cast Resin type/ Heat Shrinkable Termination Kit for Outdoor/ Indoor supply of 1.1 KV grade PVC/XLPE cable as desired by the Engineer in charge of the site:- Heat Shrinkable Outdoor/ Indoor End Termination Kit for Cable Size 3½/4 Core 225-300sq.mm

8

2556

20455.6

... More
Supply and erection of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections:- Brass Gland for Aluminium cable 2/3/4 Core size 16sq.mm

20

130

2604.2

... More
Brass Gland for Aluminium cable 3/3½/4 Core size 95-120sq.mm

16

251

4025.28

... More
Brass Gland for Aluminium cable 3/3½/4 Core size 185sq.mm

20

347

6953.2

... More
Brass Gland for Aluminium cable 3/3½/4 Core size 240sq.mm

6

450

2700.36

... More
Brass Gland for Aluminium cable 3/3½/4 Core size 300sq.mm

20

514

10290.6

... More
Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:- Aluminium thimble cable Core size 10 -16sq.mm

40

14

590

... More
Aluminium thimble cable Core size 50sq.mm

20

28

568.8

... More
Aluminium thimble cable Core size 70sq.mm

10

31

316.1

... More
Aluminium thimble cable Core size 95sq.mm

10

36

368.7

... More
Aluminium thimble cable Core size 150sq.mm

80

54

4382.4

... More
Aluminium thimble cable Core size 185sq.mm

30

65

1959.6

... More
Aluminium thimble cable Core size 300sq.mm

60

122

7332.6

... More
COPPER EARTHING (Upto 14 metre in Length):- iii- Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 10.50 metre (34.44 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 14metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 9metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- Earthing with 20mm x 3mm Copper Tape (upto 14Metre in Length)

8

18663

149307.04

... More
Earthing with 25mm x 3mm Copper Tape (upto 14Metre in Length)

14

20321

284496.38

... More
COPPER EARTHING (Upto 23 metre in Length): Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 19.50 metre (63.96 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 23metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 18metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- Earthing with 40mm x 5mm Copper Tape (upto 23Metre in Length)

4

51617

206468.32

... More
Additional Length 20mm x 3mm thick Copper Tape

160

517

82830.4

... More
Additional Length 25mm x 3mm thick Copper Tape

280

637

178404.8

... More
Additional Length 40mm x 5mm thick Copper Tape

80

1631

130499.2

... More
SUB STATION SAFETY EQUIPMENTS: Supply of Rubber hand gloves suitable for 11KV.

2

901

1802

... More
Supply & fixing of shock treatment chart both in Hindi & English for treating person suffering due to electric shock mounted on wall hooks.

2

181

362

... More
Providing and fixing H.T. danger notice plate of 250 mm x 200mm, made of mild steel at least 2mm thick and vitreous enamelled white on both sides and with inscription in single red colour on front side as required.

10

160

1600

... More
Providing and fixing M.V. danger notice plate of 200 mm x 150mm, made of mild steel at least 2mm thick and vitreous enamelled white on both sides and with inscription in single red colour on front side as required.

10

112

1120

... More
Providing and fixing of Carbon dioxide (CO2) type fire extinguishers conforming to IS 2878-1976 and cylinder fully charged of 4.5 Kg capacity.

4

7965

31860

... More
Supply and fixing of foam fire extinguishers, Portable ABC type 6Kg capacity hanged on wall with bracket component as required.

4

3813

15252

... More
Providing of set of 4 Nos. 9.5 Litre capacity GI bucket painted in post office red colour with prior coat of red - oxide paint and written with white paint 'Fire' and mounted on MS angle iron frame with bracket of appropriate size and capacity including filling sand etc.

1

5682

5682

... More
Supply of First Aid box as approved by St. John Ambulance Brigade / Indian red Cross conforming to IS 2217 -1963.

1

2278

2278

... More
Supply & fixing of fire retardant/ extinguishing Electrical insulated synthatic mat 1Mt. x 2Mt. of 2.0 mm thick +/- 10% confirming to BIS: DOC NO. ET-02 (5440) meeting requirments of IS: 15652 :2006 (with upto date amendment), suitable for all voltages not exceeding 3.3 KV and having minimum width of 1000 mm +/- 20mm and including supply of required quantity of adhensive/ compound and fixing the same at size as per site requirments.

6

2364

14184

... More
Supply & fixing of fire retardant/ extinguishing Electrical insulated synthatic mat 1Mt. x 2Mt. of minimum 3.0 mm thick +/- 10% confirming to BIS: DOC NO. ET-02 (5440) meeting requirments of IS: 15652 :2006 (with upto date amendment),, suitable for all voltages not exceeding 33 KV and having minimum width of 1000 mm +/- 20mm and including supply of required quantity of adhensive/ compound and fixing the same at size as per site requirments.

6

3437

20622

... More
Providing Silent Diesel Generating Sets: 1No. 320KVA. 1No. 650KVA, 1No. 750KVA & 1No. 1010KVA Supply, Erection, Testing and Commissioning of Silent (Sound Proof) Diesel Generator Set 320 KVA /256KW .It should be air cooled/water cooled naturally aspirated/ turbo charged/ turbo charged after cool (As per manufacturer standard). ENGINE: The Diesel engine developing 395 BHP (Approx.) for giving a power rating as per ISO 8528- Part-1 ( With CPCB-IV Norms amnded upto date) in KVA at the load terminals of alternator at 1500 rpm at actual site conditions. The engine shall confirm to IS 10000/ ISO 3046/ BS: 649/ BS 5514 amended up to date have dynamically balanced Fly wheel, air cleaner (dry/ oil bath type) as per manufacturer standard. A mechanical/ electronic governor of TYPE A1 AND A2 to maintain engine speed at all conditions of load, daily fuel service tank of minimum 8 hours running capacity as per manufacturer standard, Dry exhaust manifold with suitable exhaust residential grade silencer to reduce the noise level.suitable self-starter for 12 V/ 24 V DC ,battery charging alternator unit and voltage regulator, Lubrication oil cooler,Lubrication oil filters with replaceable elements. ENGINE CONTROL PANEL: Engine control panel fitted and having digital display i.e Start/stop key switch/push button, Battery charging indication,Engine Hours indications, Over speed indication, High water temperature indication, Lubricant oil pressure indication,) RPM indication and MCCB (Fixed Thermal and Adjustable Thermal protection) of suitable rating for outgoing supply. ALTERNATOR: The alternator should be designed as per (IS4722 and IEC:34 ) standard. Rated Power Factor : 0.8 (lag), Rated voltage : 230/415 volt, SPDP (Screen Protected Drip Proof), Degree of protection: IP-23, Ventilation : Self ventilated air cooled Alternator should have 40 degree maximum class H insulation, Automatic voltage regulator unit should be provided as per standard practice of manufacturer. Its voltage dip shall not exceed more than 20% of the rated voltage at any step load or transient load as per ISO 8528 (Part-1). Its efficiency at full load 0.8 power factor, 10% overload one hour in every 12 hrs of continuous use.

-

-

-

... More
ACOUSTIC ENCLOSURE: The enclosure shall be fabricated out the CRCA sheet of thickness not less than 1.6 mm on the outside cover with inside cover having not less than 0.6 mm thick perforated powder coated CRCA sheet. It should be IP54 Suitable for outdoor installation exposed to weather conditions, noise level up to 75 dB (A). All sheet metal parts should be processed through 7-tank pre treatment process and batteries accommodated in the battery rack .The acoustic lining should be made up of high quality insulation material i.e. Rockwool / glass/ mineral wool / PU foam of appropriate thickness & density for sound absorption.The inside of enclosure should be provided with at least one no. 28 W-T5 fluorescent tube light/ LED 10Watt luminaries controlled by a 5A switch for adequate lighting during servicing etc.with 2 year warranty from the date of installation. complete in all respect as desired by engineer at site:-The Generator set should be instaaled at site on the suitable size existing plinth of RCC as per specifacation DG set as per satisfacation of the Engineer- in-Charge at site. The model of engine will be decided by the Engineer in Charge. MANUAL CONTROL PANEL: Manual control panel shall be fabricated out of 1.6 mm sheet steel, totally enclosed, dust, damp and vermin proof wall mounted/ free standing floor mounted type with IP-53 degree of protection & front operated, composite meter for digital display, HRC fuses of suitable rating. MCCB (Fixed Thermal and Adjustable Thermal protection)/ ACB (Over cuurent/ overload, shorcircuit, instantenous, earth fault protection) should be used. Battery charger complete with voltage regulator, Voltmeter and Ammeter for charging the battery from external mains. This will be in addition to the battery charging alternator or dynamo fitted on the engine.All the components in the control panel shall be properly mounted, duly wired and labeled. Suitable terminals are to be provided for panel incoming and outgoing connections. System opeartion facility provided shall afford the following operational requirements. Necessary instruments and accessories such as voltmeter, power factor meter, KW meter, KWH meter, Ammeter, Frequency meter,battery charger complete in all respect as desired by engineer at site:-

1

3857254

3857254

... More
625-650KVA Silent DG Set: Supply, Erection, Testing and Commissioning of Silent (Sound Proof) Diesel Generator Set 625-650 KVA /520KW .It should be air cooled/water cooled naturally aspirated/ turbo charged/ turbo charged after cool (As per manufacturer standard). ENGINE: The Diesel engine developing 764 BHP (Approx.) for giving a power rating as per ISO 8528- Part-1 ( With CPCB-IV Norms amnded upto date) in KVA at the load terminals of alternator at 1500 rpm at actual site conditions. The engine shall confirm to IS 10000/ ISO 3046/ BS: 649/ BS 5514 amended up to date have dynamically balanced Fly wheel, air cleaner (dry/ oil bath type) as per manufacturer standard. A mechanical/ electronic governor of TYPE A1 AND A2 to maintain engine speed at all conditions of load, daily fuel service tank of minimum 8 hours running capacity as per manufacturer standard, Dry exhaust manifold with suitable exhaust residential grade silencer to reduce the noise level.suitable self-starter for 12 V/ 24 V DC ,battery charging alternator unit and voltage regulator, Lubrication oil cooler,Lubrication oil filters with replaceable elements. ENGINE CONTROL PANEL: Engine control panel fitted and having digital display i.e Start/stop key switch/push button, Battery charging indication,Engine Hours indications, Over speed indication, High water temperature indication, Lubricant oil pressure indication,) RPM indication and MCCB (Fixed Thermal and Adjustable Thermal protection) of suitable rating for outgoing supply. ALTERNATOR: The alternator should be designed as per (IS4722 and IEC:34 ) standard. Rated Power Factor : 0.8 (lag), Rated voltage : 230/415 volt, SPDP (Screen Protected Drip Proof), Degree of protection: IP-23, Ventilation : Self ventilated air cooled Alternator should have 40 degree maximum class H insulation, Automatic voltage regulator unit should be provided as per standard practice of manufacturer. Its voltage dip shall not exceed more than 20% of the rated voltage at any step load or transient load as per ISO 8528 (Part-1). Its efficiency at full load 0.8 power factor, 10% overload one hour in every 12 hrs of continuous use.

-

-

-

... More
ACOUSTIC ENCLOSURE: The enclosure shall be fabricated out the CRCA sheet of thickness not less than 1.6 mm on the outside cover with inside cover having not less than 0.6 mm thick perforated powder coated CRCA sheet. It should be IP54 Suitable for outdoor installation exposed to weather conditions, noise level up to 75 dB (A). All sheet metal parts should be processed through 7-tank pre treatment process and batteries accommodated in the battery rack .The acoustic lining should be made up of high quality insulation material i.e. Rockwool / glass/ mineral wool / PU foam of appropriate thickness & density for sound absorption.The inside of enclosure should be provided with at least one no. 28 W-T5 fluorescent tube light/ LED 10Watt luminaries controlled by a 5A switch for adequate lighting during servicing etc.with 2 year warranty from the date of installation. complete in all respect as desired by engineer at site:-The Generator set should be instaaled at site on the suitable size existing plinth of RCC as per specifacation DG set as per satisfacation of the Engineer- in-Charge at site. The model of engine will be decided by the Engineer in Charge. MANUAL CONTROL PANEL: Manual control panel shall be fabricated out of 1.6 mm sheet steel, totally enclosed, dust, damp and vermin proof wall mounted/ free standing floor mounted type with IP-53 degree of protection & front operated, composite meter for digital display, HRC fuses of suitable rating. MCCB (Fixed Thermal and Adjustable Thermal protection)/ ACB (Over cuurent/ overload, shorcircuit, instantenous, earth fault protection) should be used. Battery charger complete with voltage regulator, Voltmeter and Ammeter for charging the battery from external mains. This will be in addition to the battery charging alternator or dynamo fitted on the engine.All the components in the control panel shall be properly mounted, duly wired and labeled. Suitable terminals are to be provided for panel incoming and outgoing connections. System opeartion facility provided shall afford the following operational requirements. Necessary instruments and accessories such as voltmeter, power factor meter, KW meter, KWH meter, Ammeter, Frequency meter,battery charger complete in all respect as desired by engineer at site:-

1

8183369

8183369

... More
750KVA Silent DG Set: Supply, Erection, Testing and Commissioning of Silent (Sound Proof) Diesel Generator Set 750 KVA /600KW .It should be air cooled/water cooled naturally aspirated/ turbo charged/ turbo charged after cool (As per manufacturer standard). ENGINE: The Diesel engine developing suitable 901 BHP (Approx.) for giving a power rating as per ISO 8528- Part-1 ( With CPCB-IV Norms amnded upto date) in KVA at the load terminals of alternator at 1500 rpm at actual site conditions. The engine shall confirm to IS 10000/ ISO 3046/ BS: 649/ BS 5514 amended up to date have dynamically balanced Fly wheel, air cleaner (dry/ oil bath type) as per manufacturer standard. A mechanical/ electronic governor of TYPE A1 AND A2 to maintain engine speed at all conditions of load, daily fuel service tank of minimum 8 hours running capacity as per manufacturer standard, Dry exhaust manifold with suitable exhaust residential grade silencer to reduce the noise level.suitable self-starter for 12 V/ 24 V DC ,battery charging alternator unit and voltage regulator, Lubrication oil cooler,Lubrication oil filters with replaceable elements. ENGINE CONTROL PANEL: Engine control panel fitted and having digital display i.e Start/stop key switch/push button, Battery charging indication,Engine Hours indications, Over speed indication, High water temperature indication, Lubricant oil pressure indication,) RPM indication and MCCB (Fixed Thermal and Adjustable Thermal protection) of suitable rating for outgoing supply. ALTERNATOR: The alternator should be designed as per (IS4722 and IEC:34 ) standard. Rated Power Factor : 0.8 (lag), Rated voltage : 230/415 volt, SPDP (Screen Protected Drip Proof), Degree of protection: IP-23, Ventilation : Self ventilated air cooled Alternator should have 40 degree maximum class H insulation, Automatic voltage regulator unit should be provided as per standard practice of manufacturer. Its voltage dip shall not exceed more than 20% of the rated voltage at any step load or transient load as per ISO 8528 (Part-1). Its efficiency at full load 0.8 power factor, 10% overload one hour in every 12 hrs of continuous use.

-

-

-

... More
ACOUSTIC ENCLOSURE: The enclosure shall be fabricated out the CRCA sheet of thickness not less than 1.6 mm on the outside cover with inside cover having not less than 0.6 mm thick perforated powder coated CRCA sheet. It should be IP54 Suitable for outdoor installation exposed to weather conditions, noise level up to 75 dB (A). All sheet metal parts should be processed through 7-tank pre treatment process and batteries accommodated in the battery rack .The acoustic lining should be made up of high quality insulation material i.e. Rockwool / glass/ mineral wool / PU foam of appropriate thickness & density for sound absorption.The inside of enclosure should be provided with at least one no. 28 W-T5 fluorescent tube light/ LED 10Watt luminaries controlled by a 5A switch for adequate lighting during servicing etc.with 2 year warranty from the date of installation. complete in all respect as desired by engineer at site:-The Generator set should be instaaled at site on the suitable size existing plinth of RCC as per specifacation DG set as per satisfacation of the Engineer- in-Charge at site. The model of engine will be decided by the Engineer in Charge. MANUAL CONTROL PANEL: Manual control panel shall be fabricated out of 1.6 mm sheet steel, totally enclosed, dust, damp and vermin proof wall mounted/ free standing floor mounted type with IP-53 degree of protection & front operated, composite meter for digital display, HRC fuses of suitable rating. MCCB (Fixed Thermal and Adjustable Thermal protection)/ ACB (Over cuurent/ overload, shorcircuit, instantenous, earth fault protection) should be used. Battery charger complete with voltage regulator, Voltmeter and Ammeter for charging the battery from external mains. This will be in addition to the battery charging alternator or dynamo fitted on the engine.All the components in the control panel shall be properly mounted, duly wired and labeled. Suitable terminals are to be provided for panel incoming and outgoing connections. System opeartion facility provided shall afford the following operational requirements. Necessary instruments and accessories such as voltmeter, power factor meter, KW meter, KWH meter, Ammeter, Frequency meter,battery charger complete in all respect as desired by engineer at site:-

1

8927097

8927097

... More
1010KVA Silent DG Set: Supply, Erection, Testing and Commissioning of Silent (Sound Proof) Diesel Generator Set 1010 KVA /808KW .It should be air cooled/water cooled naturally aspirated/ turbo charged/ turbo charged after cool (As per manufacturer standard). ENGINE: The Diesel engine developing suitable 1210 BHP (Approx.) for giving a power rating as per ISO 8528- Part-1 ( With CPCB-II Norms amnded upto date) in KVA at the load terminals of alternator at 1500 rpm at actual site conditions. The engine shall confirm to IS 10000/ ISO 3046/ BS: 649/ BS 5514 amended up to date have dynamically balanced Fly wheel, air cleaner (dry/ oil bath type) as per manufacturer standard. A mechanical/ electronic governor of TYPE A1 AND A2 to maintain engine speed at all conditions of load, daily fuel service tank of minimum 8 hours running capacity as per manufacturer standard, Dry exhaust manifold with suitable exhaust residential grade silencer to reduce the noise level.suitable self-starter for 12 V/ 24 V DC ,battery charging alternator unit and voltage regulator, Lubrication oil cooler,Lubrication oil filters with replaceable elements. ENGINE CONTROL PANEL: Engine control panel fitted and having digital display i.e Start/stop key switch/push button, Battery charging indication,Engine Hours indications, Over speed indication, High water temperature indication, Lubricant oil pressure indication,) RPM indication and MCCB (Fixed Thermal and Adjustable Thermal protection) of suitable rating for outgoing supply. ALTERNATOR: The alternator should be designed as per (IS4722 and IEC:34 ) standard. Rated Power Factor : 0.8 (lag), Rated voltage : 230/415 volt, SPDP (Screen Protected Drip Proof), Degree of protection: IP-23, Ventilation : Self ventilated air cooled Alternator should have 40 degree maximum class H insulation, Automatic voltage regulator unit should be provided as per standard practice of manufacturer. Its voltage dip shall not exceed more than 20% of the rated voltage at any step load or transient load as per ISO 8528 (Part-1). Its efficiency at full load 0.8 power factor, 10% overload one hour in every 12 hrs of continuous use.

-

-

-

... More
ACOUSTIC ENCLOSURE: The enclosure shall be fabricated out the CRCA sheet of thickness not less than 1.6 mm on the outside cover with inside cover having not less than 0.6 mm thick perforated powder coated CRCA sheet. It should be IP54 Suitable for outdoor installation exposed to weather conditions, noise level up to 75 dB (A). All sheet metal parts should be processed through 7-tank pre treatment process and batteries accommodated in the battery rack .The acoustic lining should be made up of high quality insulation material i.e. Rockwool / glass/ mineral wool / PU foam of appropriate thickness & density for sound absorption.The inside of enclosure should be provided with at least one no. 28 W-T5 fluorescent tube light/ LED 10Watt luminaries controlled by a 5A switch for adequate lighting during servicing etc.with 2 year warranty from the date of installation. complete in all respect as desired by engineer at site:-The Generator set should be instaaled at site on the suitable size existing plinth of RCC as per specifacation DG set as per satisfacation of the Engineer- in-Charge at site. The model of engine will be decided by the Engineer in Charge. MANUAL CONTROL PANEL: Manual control panel shall be fabricated out of 1.6 mm sheet steel, totally enclosed, dust, damp and vermin proof wall mounted/ free standing floor mounted type with IP-53 degree of protection & front operated, composite meter for digital display, HRC fuses of suitable rating. MCCB (Fixed Thermal and Adjustable Thermal protection)/ ACB (Over cuurent/ overload, shorcircuit, instantenous, earth fault protection) should be used. Battery charger complete with voltage regulator, Voltmeter and Ammeter for charging the battery from external mains. This will be in addition to the battery charging alternator or dynamo fitted on the engine.All the components in the control panel shall be properly mounted, duly wired and labeled. Suitable terminals are to be provided for panel incoming and outgoing connections. System opeartion facility provided shall afford the following operational requirements. Necessary instruments and accessories such as voltmeter, power factor meter, KW meter, KWH meter, Ammeter, Frequency meter,battery charger complete in all respect as desired by engineer at site:-

1

8816271

8816271

... More
SANDWICH TYPE ALUMINIUM BUS BAR TRUNKING: (FROM DG SET TO SYNCH. PANEL) Supply, Installing testing and commissioning of 800A, 3P + 100% Neutral, 50KA For 1 Sec, Sandwich Bus trunking Straight Feeder Length, Aluminium Conductor, IP 55 with GI Enclosure in 1.5mm Thick. continuous earthing with 2 Nos integral earth conductor and Suspension Hanging system etc along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.

30

14911

447330

... More
Supply, Installing testing and commissioning of 1000A, 3P + 100% Neutral, 50KA For 1 Sec, Sandwich Bus trunking Straight Feeder Length, Aluminium Conductor, IP 55 with GI Enclosure in 1.5mm Thick. continuous earthing with 2 Nos integral earth conductor and Suspension Hanging system etc along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.

60

17357

1041420

... More
Supply, Installing testing and commissioning of 1600A, 3P + 100% Neutral, 50KA For 1 Sec, Sandwich Bus trunking Straight Feeder Length, Aluminium Conductor, IP 55 with GI Enclosure in 1.5mm Thick. continuous earthing with 2 Nos integral earth conductor and Suspension Hanging system etc along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.

30

24364

730920

... More
Supply, Installing, testing & commissioning of Elbow vertical /Horizontal /off set Bend 800Amp / 3P+1N+E (Only fabrication charges) etc.along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.

4

10107

40428

... More
Supply, Installing, testing & commissioning of Elbow vertical /Horizontal /off set Bend 1000Amp / 3P+1N+E (Only fabrication charges) etc.along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.

8

10417

83336

... More
Supply, Installing, testing & commissioning of Elbow vertical /Horizontal /off set Bend 1600Amp / 3P+1N+E (Only fabrication charges) etc.along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.

4

11656

46624

... More
Supply, Installing Flange End Unit 800 Amp (Fabrication Charges only) complete with hardware-nuts and bolts etc.along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.

2

17447

34894

... More
Supply, Installing Flange End Unit 1000 Amp (Fabrication Charges only) complete with hardware-nuts and bolts etc.along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.

4

19803

79212

... More
Supply, Installing Flange End Unit 1600 Amp (Fabrication Charges only) complete with hardware-nuts and bolts etc.along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.

2

20843

41686

... More
Supply, installation, Copper Flexible 800Amp (1 Set of 4Nos. Copper Flexible) complete with hardware-nuts and bolts etc.along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.

2

23537

47074

... More
Supply, installation, Copper Flexible 1000Amp (1 Set of 4Nos. Copper Flexible) complete with hardware-nuts and bolts etc.along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.

4

34994

139976

... More
Supply, installation, Copper Flexible 1600Amp (1 Set of 4Nos. Copper Flexible) complete with hardware-nuts and bolts etc.along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.

2

46490

92980

... More
Supply, installation, of Adopter Box/tap off box for Transformer side and panel side 800 Amp. etc.along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.

2

31808

63616

... More
Supply, installation, of Adopter Box/tap off box for Transformer side and panel side 1000 Amp. etc.along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.

4

33202

132808

... More
Supply, installation, of Adopter Box/tap off box for Transformer side and panel side 1600 Amp. etc.along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.

2

41636

83272

... More
INDOOR LT CABLES, CABLE TRAY & DWC PIPE: XLPE INSULATED UN-ARMOURED CABLES (LOOSE):- Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- Overall size 185sq.mm (3½ Core) Un-armoured (Loose) 2Runs from DG Set 320KVA to AMF Panel

200

865

173038

... More
Overall size 95sq.mm (3½ Core) Un-armoured (Loose) 2Runs from DG Set 200KVA to AMF Panel

200

453

90602

... More
PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE: Supply and erection of XLPE/ PVC insulated PVC sheathed (10 core) unarmoured copper conductor cable (ISI marked) confirm to IS:7098 (PART-I), 1988 loose in the existing trench or pipe with suitable size of copper thimbles/ lugs complete in all respect as desired by the Engineer-in-charge:- (From DG Set to AMF Panel) Overall size 2.5sq.mm (10 Core)

200

353

70668

... More
DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- Double walled corrugated (DWC) HDPE pipe 63/51 mm (outer/ inner dia.)

180

155

28065.6

... More
Double Walled Corrugated HDPE Pipe 90/76mm (Outer/ Inner dia.)

180

199

35839.8

... More
Double walled corrugated (DWC) HDPE pipe120/103.50mm (outer/ inner dia.)

180

290

52338.6

... More
COPPER EARTHING (Upto 14 metre in Length):- iii- Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 10.50 metre (34.44 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 14metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 9metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- (Body earthing & Neutral Earthing) Earthing with 25mm x 3mm Copper Tape (upto 14Metre in Length) (Body earthing & Neutral Earthing: 4Nos. for DG Set 200KVA)

4

20321

81284.68

... More
Earthing with 25mm x 5mm Copper Tape (upto 14Metre in Length) (Body earthing & Neutral Earthing: 4Nos. for DG Set 320KVA)

4

25977

103909.64

... More
Additional Length 25mm x 3mm thick Copper Tape

60

637

38229.6

... More
Additional Length 25mm x 3mm thick Copper Tape

60

1039

62388



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.