If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 4,90,919Document Cost
₹ 1,180Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_AAI_120087_1Bid Award Id
ViewTender No
AAI/ASR/EE/eNIT-02/2022-23Tender Authority
Airports Authority Of India ViewPurchaser Address
-Website
http://https://www.aai.aero/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
3.5 core x 185 sqmm
1500
-
-
... More
3.5 core x 300 sqmm
2100
-
-
... More
3.5 core x 400 sqmm
500
-
-
... More
Supplying and laying of DWC HDPE pipe (lSI marked) of following sizes along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required.
-
-
-
... More
90 mm dia (OD-90 mm & ID-76 mm nominal)
326
-
-
... More
120 mm dia (OD-120 mm & ID-103 mm nominal)
4083
-
-
... More
160 mm dia (OD-160 mm & ID-135 mm nominal)
2575
-
-
... More
200 mm dia (OD-200 mm & ID-175 mm nominal)
258
-
-
... More
Providing, laying and fixing G.l. pipe (medium class) of following diameters by proper supports for drain/naala crossing complete in as respect as required.
-
-
-
... More
100 mm dia
70
-
-
... More
150 mm dia
108
-
-
... More
Supply & laying of GI pipe (medium class) of following diameters in hard soil / surface concrete upto a depth of 40 cms. including excavation and refilling it with 1:2:4 CC to make the surface good etc. as required & as per the direction of Engineer-in-charge.
-
-
-
... More
100 mm dia
59
-
-
... More
150 mm dia
64
-
-
... More
Supply & Laying of HDPE pipe of following outer/inner dia having 6 KG/cm2 pressure rating through trenchless technology, direct in ground upto the depth of 3 meters including splicing of pipe of size complete as required.
-
-
-
... More
120 mm dia (OD-120 mm & ID-103 mm nominal)
420
-
-
... More
160 mm dia (OD-160 mm & ID-135 mm nominal)
410
-
-
... More
Laying of one no. PVC insulated and PVC sheathed / XPLE power cable of 1.1 kv grade of following size in existing RCC/ HUME/ Stoneware/Metal pipe/HDPE etc as required.
-
-
-
... More
Above 95 sq. mm and upto 185 sq. mm
5137
-
-
... More
Above 185 sq. mm and upto 400 sq. mm
3436
-
-
... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing masonry open duct as required.
-
-
-
... More
Above 95 sq. mm and upto 185 sq. mm
137
-
-
... More
Above 185 sq. mm and upto 400 sq. mm
643
-
-
... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required.
-
-
-
... More
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
20
-
-
... More
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
30
-
-
... More
Laying & fixing of one no. PVC insulated and PVC sheathed / XPLE power cable of 1.1 kv grade of following size on cable tray as required.
-
-
-
... More
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
17
-
-
... More
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
96
-
-
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
-
-
-
... More
3½ X 120 sq. mm (45mm)
2
-
-
... More
3½ X 150 sq. mm (50mm)
6
-
-
... More
3½ X 185 sq. mm (57mm)
6
-
-
... More
3½ X 240 sq. mm (62mm)
8
-
-
... More
3½ X 300 sq. mm (70mm)
5
-
-
... More
3½ X 400 sq. mm (82mm)
4
-
-
... More
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
-
-
-
... More
3½ X 120 sq. mm
1
-
-
... More
3½ X 150 sq. mm
4
-
-
... More
3½ X 185 sq. mm
3
-
-
... More
3½ X 240 sq. mm
3
-
-
... More
3½ X 300 sq. mm
3
-
-
... More
3½ X 400 sq. mm
1
-
-
... More
Supplying and making cable route marker with cement concrete1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) of size 60 cm X 60 cm at the bottom and 50cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.
12
-
-
... More
Design, fabrication, supply, installation, testing and commissioning of cubical type, dust & vermin proof, outdoor type, floor mounted electrical Feeder Pillar with IP 54 protection, suitable for 415 V, 3 phase, 50 Hz AC supply system fabricated in compartmentalised design from CRCA sheet steel of 2mm thick for frame work and covers, detachable gland plates of suitable thickness and front hinged door locking arrangment, i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having extendable TPN Aluminum Alloy bus bars of high conductivity, DMC/ SMC bus bar supports and insulators suitable for 1.1 kV. The minimum dimensions of the feeder pillar should be 600 mm (Width) x 300 mm (Depth) x 500 mm (Height). Entire panel shall have a common GI earth bar of size 25mm x 5mm at the rear with 2 Nos. earth studs along with bottom holes (4 nos.) of appropriate size for cable entry. Mounting/Grouting should be done with iron/MS angle with minimum size of 50mm x 50mm x 6mm grouted properly by cement concrete of 1:2:4 ratio up to 0.30 mtr depth and 0.30 mtr above ground level. Wherever directed by Engineer-in-Charge, provision for 02 nos. legs of same size made out of minimum 40 mm dia GI/Al. pipe alongwith breakable coupling to make the feeder pillar frangible has to made.
Bus Bar:- 600 Amps of high conductivity Aluminium busbar of minimum size 80 mm x 6 mm x 350 mm for three phase and neutral - 1 Set. Bus bar should have holes with nut bolts for terminating cables of size 3.5x400 sqmm or as directed by Engineer-in-Charge.
1
-
-
... More
Design, fabrication, supply, installation, testing and commissioning of cubical type, dust & vermin proof, outdoor type, floor mounted electrical Feeder Pillar with IP 54 protection, suitable for 415 V, 3 phase, 50 Hz AC supply system fabricated in compartmentalised design from CRCA sheet steel of 2mm thick for frame work and covers, detachable gland plates of suitable thickness and front hinged door locking arrangment, i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having extendable TPN Aluminum Alloy bus bars of high conductivity, DMC/ SMC bus bar supports and insulators suitable for 1.1 kV. The minimum dimensions of the feeder pillar should be 600 mm (Width) x 300 mm (Depth) x 500 mm (Height). Entire panel shall have a common GI earth bar of size 25mm x 5mm at the rear with 2 Nos. earth studs along with bottom holes (4 nos.) of appropriate size for cable entry. Mounting/Grouting should be done with iron/MS angle with minimum size of 50mm x 50mm x 6mm grouted properly by cement concrete of 1:2:4 ratio up to 0.30 mtr depth and 0.30 mtr above ground level. Wherever directed by Engineer-in-Charge, provision for 02 nos. legs of same size made out of minimum 40 mm dia GI/Al. pipe alongwith breakable coupling to make the feeder pillar frangible has to made.
Bus Bar:- 300 Amps of high conductivity Aluminium busbar of minimum size 50 mm x 5 mm x 350 mm for three phase and neutral - 1 Set. Bus bar should have holes with nut bolts for terminating cables of size 3.5x120/3.5x150/3.5x185 sqmm or as directed by Engineer-in-Charge.
10
-
-
... More
Design, fabrication, supply, installation, testing and commissioning of cubical type, dust & vermin proof, outdoor type, floor mounted electrical Feeder Pillar with IP 54 protection, suitable for 415 V, 3 phase, 50 Hz AC supply system fabricated in compartmentalised design from CRCA sheet steel of 2mm thick for frame work and covers, detachable gland plates of suitable thickness and front hinged door locking arrangment, i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having extendable TPN Aluminum Alloy bus bars of high conductivity, DMC/ SMC bus bar supports and insulators suitable for 1.1 kV. The minimum dimensions of the feeder pillar should be 600 mm (Width) x 300 mm (Depth) x 500 mm (Height). Entire panel shall have a common GI earth bar of size 25mm x 5mm at the rear with 2 Nos. earth studs along with bottom holes (4 nos.) of appropriate size for cable entry. Mounting/Grouting should be done with iron/MS angle with minimum size of 50mm x 50mm x 6mm grouted properly by cement concrete of 1:2:4 ratio up to 0.30 mtr depth and 0.30 mtr above ground level. Wherever directed by Engineer-in-Charge, provision for 02 nos. legs of same size made out of minimum 40 mm dia GI/Al. pipe alongwith breakable coupling to make the feeder pillar frangible has to made.
Bus Bar:- 500 Amps of high conductivity Aluminium busbar of minimum size 75 mm x 6 mm x 350 mm for three phase and neutral - 1 Set. Bus bar should have holes with nut bolts for terminating cables of size 3.5x240/3.5x300 sqmm or as directed by Engineer-in-Charge.
6
-
-
... More
Design, fabrication, supply, installation, testing and commissioning of cubical type, dust & vermin proof, outdoor type, floor mounted electrical Feeder Pillar with IP 54 protection, suitable for 415 V, 3 phase, 50 Hz AC supply system fabricated in compartmentalised design from CRCA sheet steel of 2mm thick for frame work and covers, detachable gland plates of suitable thickness and front hinged door locking arrangment, i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having extendable TPN Aluminum Alloy bus bars of high conductivity, DMC/ SMC bus bar supports and insulators suitable for 1.1 kV. The minimum dimensions of the feeder pillar should be 1000 mm (Width) x 400 mm (Depth) x 600 mm (Height). Entire panel shall have a common GI earth bar of size 25mm x 5mm at the rear with 2 Nos. earth studs along with bottom holes (4 nos.) of appropriate size for cable entry. Mounting/Grouting should be done with iron/MS angle with minimum size of 50mm x 50mm x 6mm grouted properly by cement concrete of 1:2:4 ratio up to 0.30 mtr depth and 0.30 mtr above ground level. Wherever directed by Engineer-in-Charge, provision for 02 nos. legs of same size made out of minimum 40 mm dia GI/Al. pipe alongwith breakable coupling to make the feeder pillar frangible has to made.
Bus Bar:- 400 Amps of high conductivity Aluminium busbar of minimum size 50 mm x 6 mm x 350 mm for three phase and neutral - 1 Set. Bus bar should have holes with nut bolts for terminating cables of size 3.5x150/3.5x185 sqmm or as directed by Engineer-in-Charge.
Change-over-Switch: 320A on-load - 1 no. inside the feeder pillar with 2 inputs and 1 output.
2
-
-
... More
Supply of 3 core x 35 Sqmm. 11 kV(E) grade stranded compact circular aluminium conductor, conductor screen with extruded semi conducting compound, XLPE insulated, insulation screening with extruded semi conducting compound in combination with copper tape, cores laid up, inner sheath of PVC, Galvanized steel flat strip armoured and overall PVC sheathed cable conforming to IS 7098 Part-II, 2011 with the latest amendments and as specified.
700
-
-
... More
Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for 35 sqmm, 3 core, XLPE aluminium conductor cable of 11 KV grade as required.
3
-
-
... More
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including compression glands (if required) and lugs suitable for 35 sqmm, 3 core, XLPE aluminium conductor cable of 11 kV grade as required.
1
-
-
... More
Supplying and laying of DWC HDPE pipe (lSI marked) of following sizes along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (1.2 mtr below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
120 mm dia (OD-120 mm & ID-103 mm nominal)
391
-
-
... More
Providing, laying and fixing G.l. pipe (medium class) of following diameters by proper supports for drain/naala crossing complete in as respect as required.
150 mm dia
14
-
-
... More
Supply & Laying of HDPE pipe of following outer/inner dia having 6 KG/cm2 pressure rating through trenchless technology, direct in ground upto the depth of 3 meters including splicing of pipe of size complete as required.
120 mm dia (OD-120 mm & ID-103 mm nominal)
292
-
-
... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 kV grade of following size in existing RCC/ HUME/ Stoneware/Metal pipe/HDPE etc as required.
Upto 120 sqmm
762
-
-
... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 kV grade of following size in existing masonry open duct as required.
Upto 120 sqmm
149
-
-
... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 kV grade of following size on cable tray as required.
35 sqmm (clamped with 40x3mm or suitable size MS flat clamp)
39
-
-
... More
Design, fabrication, supply, installation, testing and commissioning of outdoor type IP54 rated dust & vermin proof floor mounted electrical panel, fabricated in compartmentalized design from 2 mm thick CRCA sheet steel, complete with 7 tank process for powder coating in approved shade, with extensible aluminium bus bars with SMC busbar supports, short circuit withstand capacity of minimum 25 kA for 1 sec, copper earth strips of standard size & studs, gland plates of suitable thickness, cable alleys of suitable size for cable routing etc. complete with metering instruments, LED indicating lamps & accessories suitable for operation on 415 V, 50 Hz AC system including control wiring, interlocking arrangement between incomers & buscouplers, protections etc. suitable/compatible with following switchgears & instruments. INCOMERS
MCCB FP 250A, 25KA Ics = 100% Icu with built in thermal magnetic release- 3 Nos
BUSBARS
Extensible TPN aluminium main busbars of minimum 800A and auxiliary busbars of suitable ratings with sleeves, SMC supports at specified intervals etc.- 01 set
BUS COUPLERS
MCCB FP 250A, 25kA Ics = 100% Icu with built in thermal magnetic release- 2 Nos
OUTGOINGS
MCCB FP 125A, 25kA Ics = 100% Icu with built in thermal magnetic release- 3 Nos
MCCB FP 63A, 25kA Ics = 100% Icu with built in thermal magnetic release- 9 Nos
INSTRUMENTATION & METERING
All incoming and outgoing supplies should have digital MFM showing voltage & current levels along with selector switches, CTs/PTs of appropriate capacities & ratios, LED indication lamps as per system requirement. Mounting/Grouting of the panel should be done with iron/MS angle of suitable size grouted properly in foundation with cement concrete of 1:2:4 ratio. Wherever directed by Engineer-in-Charge, provision for 04 nos. legs of same size made out of minimum 60 mm dia GI/Al. pipe alongwith breakable coupling to make the feeder pillar frangible has to made.
1
-
-
... More
Design, fabrication, supply, installation, testing and commissioning of outdoor type IP54 rated dust & vermin proof floor mounted electrical panel, fabricated in compartmentalized design from 2 mm thick CRCA sheet steel, complete with 7 tank process for powder coating in approved shade, with extensible aluminium bus bars with SMC busbar supports, short circuit withstand capacity of minimum 25 kA for 1 sec, copper earth strips of standard size & studs, gland plates of suitable thickness, cable alleys of suitable size for cable routing etc. complete with metering instruments, LED indicating lamps & accessories suitable for operation on 415 V, 50 Hz AC system including control wiring, interlocking arrangement between incomers & buscouplers, protections etc. suitable/compatible with following switchgears & instruments. INCOMERS
MCCB FP 125A, 25KA Ics = 100% Icu with built in thermal magnetic release- 2 Nos
BUSBARS
Extensible TPN aluminium main busbars of minimum 300A and auxiliary busbars of suitable ratings with sleeves, SMC supports at specified intervals etc.- 01 set
BUS COUPLERS
MCCB FP 125A, 25kA Ics = 100% Icu with built in thermal magnetic release- 1 Nos
OUTGOINGS
MCCB FP 100A, 25kA Ics = 100% Icu with built in thermal magnetic release- 2 Nos
MCCB FP 63A, 25kA Ics = 100% Icu with built in thermal magnetic release- 2 Nos
MCCB FP 25A, 25kA Ics = 100% Icu with built in thermal magnetic release- 2 Nos
INSTRUMENTATION & METERING
All incoming and outgoing supplies should have digital MFM showing voltage & current levels along with selector switches, CTs/PTs of appropriate capacities & ratios, LED indication lamps as per system requirement.
Mounting/Grouting of the panel should be done with iron/MS angle of suitable size grouted properly in foundation with cement concrete of 1:2:4 ratio. Wherever directed by Engineer-in-Charge, provision for 04 nos. legs of same size made out of minimum 60 mm dia GI/Al. pipe alongwith breakable coupling to make the feeder pillar frangible has to made.
2
-
-
... More
Design, fabrication, supply, installation, testing and commissioning of outdoor type IP54 rated dust & vermin proof floor mounted electrical panel, fabricated in compartmentalized design from 2 mm thick CRCA sheet steel, complete with 7 tank process for powder coating in approved shade, with extensible aluminium bus bars with SMC busbar supports, short circuit withstand capacity of minimum 50 kA for 1 sec, copper earth strips of standard size & studs, gland plates of suitable thickness, cable alleys of suitable size for cable routing etc. complete with metering instruments, LED indicating lamps & accessories suitable for operation on 415 V, 50 Hz AC system including control wiring, interlocking arrangement between incomers & buscouplers, protections etc. suitable/compatible with following switchgears & instruments. INCOMERS
MCCB FP 400A, 50KA Ics = 100% Icu with built in thermal magnetic release- 3 Nos
BUSBARS
Extensible TPN aluminium main busbars of minimum 1600A and auxiliary busbars of suitable ratings with sleeves, SMC supports at specified intervals etc.- 01 set
BUS COUPLERS
MCCB FP 400A, 50kA Ics = 100% Icu with built in thermal magnetic release- 2 Nos
OUTGOINGS
MCCB FP 250A, 25kA Ics = 100% Icu with built in thermal magnetic release- 3 Nos
MCCB FP 125A, 25kA Ics = 100% Icu with built in thermal magnetic release- 6 Nos
INSTRUMENTATION & METERING
All incoming and outgoing supplies should have digital MFM showing voltage & current levels along with selector switches, CTs/PTs of appropriate capacities & ratios, LED indication lamps as per system requirement. Mounting/Grouting of the panel should be done with iron/MS angle of suitable size grouted properly in foundation with cement concrete of 1:2:4 ratio. Wherever directed by Engineer-in-Charge, provision for 04 nos. legs of same size made out of minimum 60 mm dia GI/Al. pipe alongwith breakable coupling to make the feeder pillar frangible has to made.
1
-
-
... More
Design, fabrication, supply, installation, testing and commissioning of outdoor type IP54 rated dust & vermin proof floor mounted electrical panel, fabricated in compartmentalized design from 2 mm thick CRCA sheet steel, complete with 7 tank process for powder coating in approved shade, with extensible aluminium bus bars with SMC busbar supports, short circuit withstand capacity of minimum 25 kA for 1 sec, copper earth strips of standard size & studs, gland plates of suitable thickness, cable alleys of suitable size for cable routing etc. complete with metering instruments, LED indicating lamps & accessories suitable for operation on 415 V, 50 Hz AC system including control wiring, interlocking arrangement between incomers & buscouplers, protections etc. suitable/compatible with following switchgears & instruments. INCOMERS
MCCB FP 250A, 25KA Ics = 100% Icu with built in thermal magnetic release- 2 Nos
BUSBARS
Extensible TPN aluminium main busbars of minimum 600A and auxiliary busbars of suitable ratings with sleeves, SMC supports at specified intervals etc.- 01 set
BUS COUPLERS
MCCB FP 250A, 25kA Ics = 100% Icu with built in thermal magnetic release- 1 Nos
OUTGOINGS
MCCB FP 125A, 25kA Ics = 100% Icu with built in thermal magnetic release- 2 Nos
MCCB FP 63A, 25kA Ics = 100% Icu with built in thermal magnetic release- 4 Nos
INSTRUMENTATION & METERING
All incoming and outgoing supplies should have digital MFM showing voltage & current levels along with selector switches, CTs/PTs of appropriate capacities & ratios, LED indication lamps as per system requirement. Mounting/Grouting of the panel should be done with iron/MS angle of suitable size grouted properly in foundation with cement concrete of 1:2:4 ratio. Wherever directed by Engineer-in-Charge, provision for 04 nos. legs of same size made out of minimum 60 mm dia GI/Al. pipe alongwith breakable coupling to make the feeder pillar frangible has to made.
1
-
-
... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required
29
-
-
... More
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
252
-
-
... More
Providing and fixing 25 mm X 5 mm G.I.strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut,bolt, spring, washer excavation and re-filling etc. as required.
87
-
-
... More
Providing and fixing 25 mm X5 mm G.I. strip on surface or in recess for connections etc. as required.
29
-
-