Puducherry Smart City Development Limited Tender
View complete overview of Puducherry Puducherry Smart City Development Limited Tender
Puducherry Smart City Development Limited Tender
Eprocure
Opening Date29 Oct 2021
Closing Date17 Nov 2021
Tender Amount₹ 1,27,32,053 This is an estimated amount, exact amount may vary.
Costs
EMD
Refer DocumentsDocument Cost
₹ 1,500Tender Fee
Refer Documents
Summary
Electrification Works In Mini Sports Stadium At Annathidal, Puducherry
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_PSCDL_8659_1Bid Award Id
ViewTender No
009/PSCDL/2021Tender Authority
Puducherry Smart City Development Limited ViewPurchaser Address
-Website
http://https://pondicherrysmartcity.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Wiring for light /power plug with 2x4 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 No.4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
900
-
-
Wiring for circuit / sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor , single core cable in surface / recessed medium class PVC conduit as required - 2 X 2.5 sq.mm + 1 x 2.5 sq.mm earth
3643
-
-
Wiring for circuit / sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor , single core cable in surface / recessed medium class PVC conduit as required - 2 X 4 sq.mm + 1 x 4 sq.mm earth wire
4040
-
-
Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface / recessed steel / PVC conduit as required -3 x 6 sq.mm
9462
-
-
Wiring for circuit / sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor , single core cable in surface / recessed medium class PVC conduit as required - 4 X 16 sq.mm + 2 x 6 sq.mm earth wire
252
-
-
PVC CONDUITS AND ACCESSORIES Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required - 20mm
372
-
-
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required - 25mm
16512
-
-
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required - 32mm
60
-
-
Supplying and fixing 3 pin , 5 A ceiling rose on the existing junction box / wooden block including connection etc as required
307
-
-
Supplying and fixing following size / modules , GI box along with modular base & cover plate for modular switches in recess etc. as required - 1 or 2 module (75mm x 75mm)
6
-
-
Supplying and fixing following size / modules , GI box along with modular base & cover plate for modular switches in recess etc. as required - 3 module (100mm x 75mm)
18
-
-
Supplying and fixing following size / modules , GI box along with modular base & cover plate for modular switches in recess etc. as required - 4 module (125 mm x 75 mm)
2
-
-
Supplying and fixing following size / modules , GI box along with modular base & cover plate for modular switches in recess etc. as required - 6 module (200 mm x 75 mm)
2
-
-
Supplying and fixing following size / modules , GI box along with modular base & cover plate for modular switches in recess etc. as required - 8 module (125 mm x 125 mm)
2
-
-
Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required - 5/6 A switch
12
-
-
Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required - 15/16 A switch
6
-
-
Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required - 3 pin 5/6 A socket outlet
12
-
-
Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required - 6 pin 15/16 A socket outlet
6
-
-
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess , including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch , connections etc , as required
478
-
-
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess , including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/6 A modular switch , connections etc , as required.
220
-
-
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlets and 2 nos. 5/6 A modular switches , connection etc. as required.
5
-
-
Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc .as required.
19
-
-
TELEPHONE Supplying and fixing RJ 11 modular type Telephone outlet and modular plate in cadmium / GI plated MS box including making connections etc as required. Make: MK / Creabtree
5
-
-
DATA NETWORKING Supplying and fixing Data socket outlet modular type and modular plate in cadmium / GI plated MS box including making connections etc as required. Make: MK / Crabtree
8
-
-
CABLE Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required - 4 X16 sq.mm (28 mm)
18
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required - 4 X25 sq.mm (28 mm)
2
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required - 4 X50 sq.mm (35 mm)
22
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required - 31/2 X95 sq.mm (45 mm)
12
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required - 31/2 X240 sq.mm (62 mm)
2
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required - 31/2 X300 sq.mm (70 mm)
8
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required - 31/2 X400 sq.mm (82 mm)
4
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation , sand cushioning, protective covering and refilling the trench etc. as required - Upto 35 sq.mm
900
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation , sand cushioning, protective covering and refilling the trench etc. as required - above 35 sq.mm and upto 95 sq.mm
893
-
-
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation , sand cushioning , protective covering and refilling the trench etc. as required - above 185 sq.mm and upto 400 sq.mm
527
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC / HUME / METAL pipe as required - above 185 sq.mm and upto 400 sq.mm
21
-
-
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required - upto 35 sq.mm (clamped with 1mm thick saddle)
60
-
-
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required - above 35 sq.mm and upto 95 sq.mm (clamped with 25 x3mm MS flat clamp)
102
-
-
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required - above 185 sq.mm and upto 400 sq.mm (clamped with 40 x3mm MS flat clamp)
42
-
-
CABLE TRAY AND TRENCH Supplying and installing following size of perforated Hot dipped Galvanised iron cable tray (galvanization thickness not less than 50 microns) with perforation not more than 17.5% , in convenient sections , joined with connectors , suspended from the ceiling with G.I. suspenders including G.I .bolts & nuts , etc .as required - 150 mm width x 50 mm depth x 1.6mm thickness
96
-
-
Supplying and installing following size of perforated Hot dipped Galvanised iron cable tray (galvanization thickness not less than 50 microns) with perforation not more than 17.5% , in convenient sections , joined with connectors , suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts , etc .as required - 300 mm width x 50 mm depth x
180
-
-
Supplying and installing following size of perforated Hot dipped galvanized iron cable tray "bends" (galvanization not less than 50 microns) with perforation not more than 17.5% , in convenient sections , joined with connectors , suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts , etc. as required - 150 mm width x 50 mm depth x 1.6 mm thickness
4
-
-
Supplying and installing following size of perforated Hot dipped galvanized iron cable tray "bends" (galvanization not less than 50 microns) with perforation not more than 17.5% , in convenient sections , joined with connectors , suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts , etc. as required - 300 mm width x 50 mm depth x 1.6 mm thickness
2
-
-
Excavation for cable trenches in soft soil , depth upto 1.2 m including dressing of sides lift upto 1.5m , including getting out the excavated soil , refilling with sand and good soil after laying of cable / pipe etc. in layers of 20cm , ramming, watering and disposal of surplus excavated soil as directed , within a lead of 50 meters
624
-
-
Supply of GI pipe 100 mm dia
21
-
-
EARTHING Supplying and installing following size of perforated Hot dipped galvanized iron cable tray "Tee" (galvanization not less than 50 microns) with perforation not more than 17.5% , in convenient sections , joined with connectors , suspended from the ceiling
2
-
-
Providing and fixing 25mm x 5mm GI. Strip on surface or in recess for connections etc. as required
1066
-
-
Providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc as required
96
-
-
TELEPHONE Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor , unarmored telephone cable in the existing surface / recessed steel / PVC conduit as required - two pair
594
-
-
DATA NETWORKING Supplying and drawing of UTP 4 pair CAT 6 LAN cable in the existing surface / recessed Steel / PVC Conduit as required - 1 run of cable.
618
-
-
CCTV Supplying and drawing of UTP 4 pair CAT 6 LAN cable in the existing surface / recessed Steel / PVC Conduit as required - 1 run of cable.
3720
-
-
CABLE Supply of 4 x 16sqmm PVC sheathed armoured aluminium U.G cable - 1.1 KV grade. Make: Finolex/ Poly cab
750
-
-
Supply of 4 x 25sqmm PVC sheathed armoured aluminium U.G cable - 1.1 KV grade. Make: Finolex/ Poly cab
210
-
-
Supply of 4C x 50 sq mm PVC sheathed armoured aluminium U.G cable- 1.1 KV grade. Make: Finolex /Poly cab
887
-
-
Supply of 3 1/2 x 95sqmm PVC sheathed armoured aluminium U.G cable- 1.1 KV grade. Make: Finolex /Poly cab
108
-
-
Supply of 3 1/2 x 240sqmm PVC sheathed armoured aluminium U.G cable- 1.1 KV grade. Make: Finolex/ Poly cab
36
-
-
Supply of 3 1/2 x 300sqmm PVC sheathed armoured aluminium U.G cable- 1.1 KV grade. Make: Finolex /Poly cab
473
-
-
Supply of 3 1/2 x 400sqmm PVC sheathed armoured aluminium U.G cable- 1.1 KV grade. Make: Finolex/ Poly cab
60
-
-
PANEL Supply of outdoor type (IP 65) LT Pillar boxes fabricated with 14G CRCA sheet steel and powder coated, aluminium bus bars, provision for incoming and outgoing cable terminations, the incoming and outgoing switchgears are as per the followings. The items including necessary control wiring, safety features, lock & key / sealing arrangements and providing necessary, support structure/frames with painting as required for erection. All complete with necessary fixing accessories etc. All complete as required by PED standards & specifications.
6 way 600 Amps SS Pillar Box
2
-
-
6 way 400/600 Amps Distribution Pillar Box
4
-
-
Installation, testing and commissioning of outdoor type (IP 65) LT Pillar boxes fabricated with 14G CRCA sheet steel and powder coated, aluminium bus bars, provision for incoming and outgoing cable terminations, the incoming and outgoing switchgears are as per the followings. The items including necessary control wiring, safety features, lock & key/ sealing arrangements, civil works and providing necessary, support structure/frames with painting as required for erection. All complete with necessary fixing accessories etc. All complete as required by PED standards & specifications.
6 way 600 Amps SS Pillar Box
2
-
-
6 way 400/600 Amps Distribution Pillar Box
4
-
-
Supply, installation, testing and commissioning of 415V metering panel board fabricated with 14G CRCA sheet steel, powder coated with Siemens gray (RAL7032 IS-5) after seven tank process, complete with aluminium bus bars (the clearance shall not less than 25 mm for phase-phase and 19mm for phase-neutral/earth), 3.15mm sheet steel or 40x40x6mm MS angle for load bearing members, lifting hooks, MS base frame of 75mm height incomers and outgoing switchgear as below. The item including cost of supply and fixing of 3-phase energy meters, necessary sealing arrangements, 25x3mm GI earthing throughout the bottom length, 6 sq.mm FRLS copper wire inter connections for compartment earthing, complete copper control wiring with crimping type ferrules, copper lugs, proper engravation sheet to be fixed on each outgoing etc. Also the cost inclusive of minor civil works and providing necessary, support structure/frames with painting as required for erection. All complete as per specifications, drawing and/or as required by CEA/PED. The contractor shall submit general arrangement & control wiring drawings and get approval from site Engineer/Consultant before commence the fabrication works. Note: panels costing should be as per sold & with respect to PED standards
-
-
-
Metering Panel-1 Incomer : 160A TPN FSU : 1 no. Outgoings : 24 Sets each comprising of: a) 32A DP Fuse cut outs with neutral link. b) Single phase Energy meter as per PED requirement. c) 32A DP MCB (C - curve 10KA) 1 Sets each comprising of: a) 63A TPN Fuse cut outs with neutral link. b) Three phase Energy meter as per PED requirement. c) 63A FP MCB (C - curve 10KA)
1
-
-
Metering Panel-2 Incomer : 125A TPN FSU : 1 no. Outgoings : 12 Sets each comprising of: a) 32A DP Fuse cut outs with neutral link. b) Single phase Energy meter as per PED requirement. c) 32A DP MCB (C - curve 10KA)
1
-
-
Metering Panel-3 Incomer : 160A TPN FSU : 1 no. Outgoings : 18 Sets each comprising of: a) 32A DP Fuse cut outs with neutral link. b) Single phase Energy meter as per PED requirement. c) 32A DP MCB (C - curve 10KA) 3 Sets each comprising of: a) 63A TPN Fuse cut outs with neutral link. b) Three phase Energy meter as per PED requirement. c) 63A FP MCB (C - curve 10KA)
1
-
-
Metering Panel-4 Incomer : 160A TPN FSU : 1 no. Outgoings : 26 Sets each comprising of: a) 32A DP Fuse cut outs with neutral link. b) Single phase Energy meter as per PED requirement. c) 32A DP MCB (C - curve 10KA) 1 Sets each comprising of: a) 63A TPN Fuse cut outs with neutral link. b) Three phase Energy meter as per PED requirement. c) 63A FP MCB (C - curve 10KA)
1
-
-
Metering Panel-5 Incomer : 125A TPN FSU : 1 no. Outgoings : 16 Sets each comprising of: a) 32A DP Fuse cut outs with neutral link. b) Single phase Energy meter as per PED requirement. c) 32A DP MCB (C - curve 10KA)
1
-
-
Metering Panel-6 Incomer : 125A TPN FSU : 1 no. Outgoings : 16 Sets each comprising of: a) 32A DP Fuse cut outs with neutral link. b) Single phase Energy meter as per PED requirement. c) 32A DP MCB (C - curve 10KA)
1
-
-
Metering Panel-7 Incomer : 160A TPN FSU : 1 no. Outgoings : 32 Sets each comprising of: a) 32A DP Fuse cut outs with neutral link. b) Single phase Energy meter as per PED requirement. c) 32A DP MCB (C - curve 10KA)
1
-
-
Metering Panel - 8 Incomer : 125A TPN FSU : 1 no. Outgoings : 24 Sets each comprising of: a) 32A DP Fuse cut outs with neutral link. b) Single phase Energy meter as per PED requirement. c) 32A DP MCB (C - curve 10KA) 1 Sets each comprising of: a) 63A TPN Fuse cut outs with neutral link. b) Three phase Energy meter as per PED requirement. c) 63A FP MCB (C - curve 10KA)
1
-
-
Metering Panel- 9 Incomer : 160A TPN FSU : 1 no. Outgoings : 32 Sets each comprising of: a) 32A DP Fuse cut outs with neutral link. b) Single phase Energy meter as per PED requirement. c) 32A DP MCB (C - curve 10KA) 1 Sets each comprising of: a) 63A TPN Fuse cut outs with neutral link. b) Three phase Energy meter as per PED requirement. c) 63A FP MCB (C - curve 10KA)
1
-
-
UTILITY PANEL i) 100A, TPN, 25KA, MCCB with thermal magnetic releases and rotary handle mechanism & spreader - 1 No. 100A 4P 25KA on load Auto Transfer Switch with ON delay Timer, Auxiliary relay/contactor, single phase preventer, control MCB's, ON/OFF push buttons, MFn meter, phase indications etc. - 1 No. Phase indication lamps(R,Y,B) - 1 set. ON/OFF/TRIP Indication lamps - 1 set. CT ratio 100/5A,CL:1.0 tape insulated bar primary type with suitable sorting links. - 3Nos. - 1 Set. Metering: Multifunction meters cl:1.0 measured with following parameters: V,A,F,PF,KW,KWH & Phase sequence. - 1 Set Bus bar: i)100A, TPN, 25KA, for 1 sec Aluminium bus bars ii) Phase: current density not more than 0.8A/sq.mm iii) Neutral: half of the phase current (0.5 x phase) iv) Earth: 25x3mm copper flat Outgoing: i) 63A, FP, 10KA, MCB 'C' Curve - 04 Nos. ii) 32A, FP, 10KA, MCB 'C' Curve - 04 Nos. iii) 25A, FP, 10KA, MCB 'C' Curve - 02 Nos.
1
-
-
COMMON AREA PANEL - 1 i) 100A, TPN, 25KA, MCCB with thermal magnetic releases and rotary handle mechanism & spreader - 1 No. 100A 4P 25KA on load Auto Transfer Switch with ON delay Timer, Auxiliary relay/contactor, single phase preventer, control MCB's, ON/OFF push buttons, MFn meter, phase indications etc. - 1 No. Phase indication lamps(R, Y, B) - 1 set. ON/OFF/TRIP Indication lamps - 1 set. CT ratio 100/5A, CL: 1.0 tape insulated bar primary type with suitable sorting links. - 3Nos. - 1 Set. Metering: Multifunction meters cl: 1.0 measured with following parameters: V,A,F,PF,KW,KWH & Phase sequence. - 1 Set Bus bar: i) 100A, TPN, 25KA, for 1 sec Aluminium bus bars ii) Phase: current density not more than 0.8A/sq.mm iii) Neutral: half of the phase current (0.5 x phase) iv)Earth: 25x3mm copper flat Outgoing: i) 63A, FP, 10KA, MCB 'C' Curve - 06 Nos. ii) 32A, DP, 10KA, MCB 'C' Curve - 07 Nos. iii) 25A, FP, 10KA, MCB 'C' Curve - 02 Nos.
1
-
-
COMMON AREA PANEL - 2 i) 100A, TPN, 25KA, MCCB with thermal magnetic releases and rotary handle mechanism & spreader - 1 No. 100A 4P 25KA on load Auto Transfer Switch with ON delay Timer, Auxiliary relay/contactor, single phase preventer, control MCB's, ON/OFF push buttons, MF n meter, phase indications etc. - 1 No. Phase indication lamps(R, Y, B) - 1 set. ON/OFF/TRIP Indication lamps - 1 set. CT ratio 100/5A,CL:1.0 tape insulated bar primary type with suitable sorting links. - 3Nos. - 1 Set. Metering: Multifunction meters cl: 1.0 measured with following parameters: V, A, F, PF, KW, KWH & Phase sequence. - 1Set Bus bar: i) 100A, TPN, 25KA, for 1 sec Aluminium bus bars ii) Phase: current density not more than 0.8A/sq.mm iii) Neutral: half of the phase current (0.5 x phase) iv) Earth: 25x3mm copper flat Outgoing: i) 63A, FP, 10KA, MCB 'C' Curve - 06 Nos. ii) 32A, DP, 10KA, MCB 'C' Curve - 04 Nos. iii) 25A, FP, 10KA, MCB 'C' Curve - 02 Nos.
1
-
-
ADMIN PANEL i) 100A, TPN, 25KA, MCCB with thermal magnetic releases and rotary handle mechanism & spreader - 1 No. 100A 4P 10KA on load Auto Transfer Switch with ON delay Timer, Auxiliary relay/contactor, single phase preventer, control MCB's, ON/OFF push buttons, MFn meter, phase indications etc. - 1 No. Phase indication lamps(R,Y,B) - 1 set. ON/OFF/TRIP Indication lamps - 1 set. Metering: Multifunction meters cl: 1.0 measured with following parameters: V, A, F, PF, KW, KWH & Phase sequence. - 1Set Bus bar: i) 100A, TPN, 25KA, for 1 sec Aluminium bus bars ii) Phase: current density not more than 0.8A/sq.mm iii) Neutral: half of the phase current (0.5 x phase) iv) Earth: 25x3mm copper flat Outgoing: i) 40A, FP, 10KA, MCB 'C' Curve - 02 Nos. ii) 32A, FP, 10KA, MCB 'C' Curve - 02 Nos.
1
-
-
TELEPHONE Supplying and drawing of 10 Pair, FR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
20
-
-
Supply and fixing of 10-pair telephone Krone type junction box enclosed in MS box with hinged cover with lock & key arrangements, all complete as per specifications, drawings and / or as directed by the Engineer.
1
-
-
EARTHING Supply of Potential Earth Electrodes Model STANDARD PS53C 48mm dia, wall thickness 3.25mm, terminal size :32 x 10 mm, terminal hole dia 12 mm, hot dip galvanized 80 to 100 microns, 3 meter long, pipe inner space filled with high conductive material, including 2 bags (25kg per bag) of Earth Life Compound , as IS 3043. Base Metal: IS marked branded mild steel pipes.
22
-
-
Supply and providing the following safety items as per the requirements of statutory authorities:
-
-
-
Supplying of fire bucket painted red & approved (set of 4 buckets)
1
-
-
Supplying and fixing danger plate 11KV written in two languages
2
-
-
Supply of hand gloves suitable for 11 KV
2
-
-
Supplying of non skid rubber mat 12mm thick and 900mm width.
2
-
-
Supplying and fixing of shock treatment chart
1
-
-
Supplying and fixing danger plate 440 volts written in two languages
9
-
-
Supply and fixing carbon di oxide fire extinguisher type 4.5Kg capacity
9
-
-
Obtaining CEA Approval for energisation (safety certificate) of the installations after preparation & submission of drawings, documents relevant for the same.
1
-
-
DISTRIBUTION BOARD Supplying and fixing following way , horizontal type three pole and neutral , sheet steel , MCB distribution board , 415 V, on surface / recess , complete with tinned copper bus bar , neutral bus bar , earth bar , din bar, Interconnections , powder painted including earthing etc. as required (but withoutMCB / RCCB / Isolator ) 8way (4+24) , double door
3
-
-
Supplying and fixing following way , horizontal type three pole and neutral , sheet steel , MCB distribution board , 415 V, on surface / recess , complete with tinned copper bus bar , neutral bus bar , earth bar , din bar, Interconnections , powder painted including earthing etc. as required (but without MCB / RCCB / Isolator ) 6way (4+18) , double door
2
-
-
Supplying and fixing following way , horizontal type three pole and neutral , sheet steel , MCB distribution board , 415 V, on surface / recess , complete with tinned copper bus bar , neutral bus bar , earth bar , din bar, Interconnections , powder painted including earthing etc. as required (but without MCB / RCCB / Isolator ) 4way (4+12) , double door
3
-
-
Supplying and fixing following way, single pole and neutral , sheet steel , MCB distribution board , 240 V, on surface / recess, complete with tinned copper bus bar , neutral bus bar , earth bar , din bar , interconnections , powder painted including earthing etc. as required (But without MCB / RCCB /
8
-
-
Supplying and fixing following way , single pole and neutral , sheet steel , MCB distribution board , 240 V, on surface / recess, complete with tinned copper bus bar , neutral bus bar , earth bar , din bar , interconnections , powder painted including earthing etc. as required (But without MCB / RCCB / Isolator) - 8 way ,double door
200
-
-
Supplying and fixing Cable End Box (loose wire box) (IP 43) suitable for following triple pole and neutral , sheet steel , MCB distribution board , 415 V, on surface / recess, complete with testing and commissioning etc. as required. For 8 way , double door TPN MCBDB
3
-
-
Supplying and fixing Cable End Box (loose wire box) (IP 43) suitable for following triple pole and neutral , sheet steel , MCB distribution board , 415 V, on surface / recess, complete with testing and commissioning etc. as required. For 6 way , double door TPN MCB DB
2
-
-
Supplying and fixing DP sheet steel enclosure on surface / recess along with 25 / 32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
2
-
-
Supplying and fixing 5 A to 32 A rating , 240/415 V, 10 kA, "C" curve , miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections , testing and commissioning etc. as required. - Single Pole
1353
-
-
Supplying and fixing 5 A to 32 A rating , 240/415 V, 10 kA, "C" curve , miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections , testing and commissioning etc. as required. - Single Pole Commissioning etc .as required. - Triple Pole
3
-
-
Supplying and fixing following rating, double pole , (single phase and neutral), 240V , residual current circuit breaker (RCCB), having a sensitivity current 30 m A in the existing MCB DB complete with connections , testing and commissioning etc as required - 25 A
208
-
-
Supplying and fixing following rating, double pole , (single phase and neutral), 240V , residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections , testing and commissioning etc as required - 40 A
15
-
-
Supplying and fixing following rating, double pole , (single phase and neutral), 240V , residual current circuit breaker (RCCB), having a sensitivity current 30 m A in the existing MCB DB complete with connections , testing and commissioning etc as required - 63 A
9
-
-
Supplying and fixing following rating , four pole ,415 V , isolator in the existing MCB DB complete with connections , testing and commissioning etc. as required - 40 A
11
-
-
Supplying and fixing following rating , four pole ,415 V , isolator in the existing MCB DB complete with connections , testing and commissioning etc. as required - 63 A
3
-
-
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required
12
-
-
LIGHT FIXTURES / FAN Installation, testing and commissioning of wall bracket / ceiling fittings of all sizes and shapes containing upto two GLS / CFL /LED lamps per fitting. Complete with all accessories including connections etc as required.
333
-
-
Supply of ceiling fan Sweep 1200mm Fusion - 50 Energy saving fan five star. Make: Hevells.
249
-
-
Stepped type Modular Fan regulator (2 module)
249
-
-
3mm thick mica plate for fan hook box (L.M.R)
249
-
-
Concealed type ceiling fan metal hook. (L.M.R)
249
-
-
Installation testing and commissioning of ceiling fan/wall mounting fan and wiring the down rod of standard length .(upto 30cm) with 14/.86mm Plastic insulated twisted Copper wire including earthing as
249
-
-
Supply of 300mm 1400 rpm heavy duty exhaust fan Make:Almonard/Orient/Usha
21
-
-
Installation of exhaust fan in the existing opening , including making good the damage , connection , testing ,commissioning etc. as required - Upto 450 mm sweep
21
-
-
LIGHT FIXTURES fixing Step type socket Fan Regulator on the existing switch box/cover including connections etc. as required.
249
-
-
Supplying of 230V, 1 x 20W LED ceiling mounted type light fitting with suitable 20W LED lamp and necessary fixing accessories as required. Make: Philips/Bajaj
18
-
-
Supplying of 230V, 1 x 24W LED ceiling mounted type light fitting with suitable 24W LED lamp and necessary fixing accessories as required. Make: Philips/Bajaj
70
-
-
Supplying of 230V, 1 x 18W LED wall mounted light fitting with suitable 18W LED lamp and necessary fixing accessories as required. Make: Philips/Bajaj
235
-
-
Supplying and fixing of LED 4000K 2 x 2 Square Type Recessed Fitting. (Philips / Havells )
6
-
-
Supply and Fixing of 20W LED tube light fitting Make: Philips / Bajaj / Benio
582
-
-
Supplying of 1 x 10 LED 2' Washbasin light fittings with suitable 10W LED lamp and necessary fixing accessories as required. Make: Philips/Bajaj
10
-
-
Supplying and fixing of 230V, 1 x 34W LED ceiling mounted type light fitting with suitable 34W LED lamp and necessary fixing accessories as required. Make: Philips/Bajaj
6
-
-
DATA NETWORKING Supply, installation, testing and commissioning of 16 port Data switches with rack, the rate shall be inclusive of all required civil works. (Make: Netgear / Digilink)
1
-
-
CAMERA Supplying and fixing of wall or ceiling mounted type Fixed Dome or Bullet type Camera 2.0 Megapixel high- performance CMOS, Analog HD output, up to 1080P resolution True Day/Night, DNR, Smart IR Up to 30m IR distance, IP66 weatherproof with all necessary BNC connectors and fixing accessories as required.
30
-
-
Supply, fixing and termination of high quality rack mounted type patch panel with one number of 24 port POE network switch, fixing frames, links and interconnections, necessary accessories etc., all complete as per specifications, drawings and / or as directed by the Engineer.
2
-
-
Supply of wall Mounted network rack - 9U door of glass, completely covered and have security lockers, proper ventilated with one fan one cable manager, power distribution units of 6nos (5A) sockets with surge protection, mounting accessories and 5A top Ventilation switch.
2
-
-
Installation of wall Mounted network rack - 9U door of glass, complete covered and have security locks, proper ventilated with one fan one cable manager, power distribution units of 6nos(5A) sockets with surge protection, mounting accessories and 5A top Ventilation switch.
2
-
-
Supplying and installing of 64 Channel Network Video Recorder with Max 320Mbps incoming bandwidth Smart H.265+/H.265/ Smart H.264+/H.264/ MJPEG Up to 12MP resolution preview and playback Support 8 SATA HDDs up to 10TB Each, 4 USB (2 USB3.0, 2USB2.0) 2 HDMI / 2VGA simultaneous video output Support Multi-brand network cameras Support RAID 0/1/5/10 Mobile Software: iCMOB, gCMOB CMS Software: KVMS Pro. The items including supply of 6TB hard disk, connectors, pins and providing complete configuration etc.
1
-
-
Supplying and installing of Power Supply Unit along with necessary Battery backup, suitable for 1nos. 64 channel network video recorder system.
1
-
-
Supplying and installing of 43" LED colour monitor.
3
-
-
INVERTER SYSTEM Supply and erection of 1 Phase, 230 V, 2 k VA 1P -n 1P out /INVERTER with suitable BCB (battery circuit breaker), filters, 6 nos. 12V 28Ah SMF battery bank, with 30minutes backup. The items including necessary safety features, protections/relays, necessary battery racks, cables/wires and fixing accessories etc.
1
-
-
Evaluation Notes How It Works ?