Puducherry Slum Clearance Board Tender
View complete overview of Puducherry Puducherry Slum Clearance Board Tender
Puducherry Slum Clearance Board Tender
Civil And Construction
Building Construction
Eprocure
Opening Date4 Jul 2024
Closing Date16 Jul 2024
Tender Amount₹ 9,15,579
Costs
EMD
₹ 18,312Document Cost
₹ 525Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PSCB_16020_1Bid Award Id
ViewTender No
02_pscb_2023_24Tender Authority
Puducherry Slum Clearance Board ViewPurchaser Address
-Website
http://pudutenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Special repairs to the existing office building of Puducherry Slum Clearance Board at Savanapet Periyar nagar Puducherry 3rd call
Special repairs to the existing office building of Puducherry Slum Clearance Board at Savanapet Periyar nagar Puducherry 3rd call
BOQ Items
CODE NO:6.1.2: Brick work with common burnt clay F.P.S. (non modular ) bricks of class designation 7.5 in foundation and plinth in - cement mortar 1:6 (1 cement : 6 coarse sand)
1
-
-
CODE NO:6.12.2: Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in - cement mortar 1:4 (1 cement :4 coarse sand)
1
-
-
CODE NO: 9.105.4: Providing and fixing partition upto ceiling height consisting of G.I. frame and required board , including providing and fixing of frame work made of special section power pressed / roll form G.I. sheet with zinc coating of 120 gms / sqm (both side inclusive ), consisting of floor and ceiling channel 50mm wide having equal flanges of 32 mm and 0.50 mm thick , fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm diametre 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre , and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre . The boards are to be fixed to the frame work with joints staggered to avoid through cracks , M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards , fixed to the studs using metal to metal flat head screws , including jointing and finishing to a flush finish with recommended jointing compound , jointing tape , angle beads at corners (25 mm X 25 mm X 0.5 mm) , joint finisher and two coats of primer suitable for board as per manufacture,s specification and all complete - 66 mm overall thickness partition using 8 mm thick double skin non - asbestos multipurpose cement board reinforced with cellulose fibre manufactured through autoclaving process (High pressure steam cured) as per IS : 14862 with suitable fibre cement screws
4
-
-
CODE NO:9.120.2: Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S.tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15 x15 mm for top & bottom rails. M.S.frame shall have a coat of steel primers of approved make and manufacture . M.S. frame covered with 5 mm thick heat moulded PVC 'C' channel of size 30mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top , bottom and lock rails shall be provided both side of the panel. 10mm (5 mm x 2) thick , 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail , panelling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded / sealed to the styles & rails with 7 mm (5 mm + 2 mm) thick x 15 mm wide PVC sheet beading on innerside , and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the C" Channel using PVC sol vent adhesive etc. omplete manufacturer's specification & drawing - 30mm thick pre laminated PVC door shutters
7
-
-
CODE NO: 9.127.2: Providing & fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 type S, including cost of adhesive of approved quality - 1.0 mm thick
17
-
-
CODE NO: 10.16.1: Steel work in built up tubular (round,square or rectanglar hollow tubes etc.) trusses etc., including cutting , hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete - hot finished welded type tubes
320
-
-
CODE NO:11.1.1: Brick on edge flooring with bricks of class designation 7.5 on a bed of 12mm cement mortar , including filling the joints with same mortar , with common burnt clay non modular bricks - cement mortar 1:4 (1 cement : 4 coarse sand)
18
-
-
CODE NO: 11.36D: Providing and fixing commercial quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer) , of approved make (Jhonson / Asian / Somany / Nitco) in all colours , shades of size 200 x 300 mm as approved in skirting , risers of steps and dados, over 12mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement with pigment of matching shade complete - size 200x300 mm
85
-
-
CODE NO: 11.37.2: Providing and laying ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of commercial quality conforming to IS : 15622, of approved make (Bell / Johnson / Regency / Somany / Naveen / Asian) in colours such as white, Ivory, Grey, Fume red brown ,laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including pointing the joints with white cement and matching pigment etc., complete
55
-
-
CODE NO:12.20: Providing and laying pressed clay tiles (as per approved pattern 18mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound , laid over a bed of 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete
20
-
-
CODE NO:12.42.3.1: Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion - Single tee with door - 75 x75x75mm
4
-
-
CODE NO:12.42.6.1: Providing and fixing on wall face unplasticised - PVC moulded fittings /accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion - shoe (plain) - 75mm shoe
4
-
-
CODE NO:12.42.6.2: Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion - shoe (plain) - 110mm shoe
2
-
-
CODE NO:12.51.1: Providing and fixing precoated galvanised steel sheet roofing accessories 0.5mm(+0.05%) total coated thickness , zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both sides of the sheet and polyster top coat 15-18 microns using self drilling / self tapping screws complete - Ridges plain (500 - 600mm)
25
-
-
CODE NO:13.1.1: 12mm cement plaster of mix -1:4 ( 1 cement : 4 fine sand)
12
-
-
CODE NO:13.2.1: 15mm cement plaster on the rough side of single or half brick wall of mix - 1:4 (1cement : 4 fine sand)
17
-
-
CODE NO:13.48.1: Finishing with deluxe multi surface paint system for interiors and exteriors using primer as per manufacture's specification - Two or more coats applied on walls @ 1.25 ltr / 10 sqm over and including one coat of special primer applied @ 0.75 ltr / 10 sqm
2940
-
-
CODE NO:14.1.1: Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq.metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 metres lead -with cement mortar 1:4 (1 cement : 4fine sand)
153
-
-
CODE NO:14.42.1: White washing with lime to give an even shade - Old work (two or more coats)
835
-
-
CODE NO:14.43: Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scrarches etc. complete
105
-
-
CODE NO:14.54.1: Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade - One or more coats on old work
560
-
-
CODE NO:15.2.1: Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead - nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
0.5
-
-
CODE NO:15.3: Demolishing R.C.C work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead
5
-
-
CODE NO:15.7.4: Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead - in cement mortar
4
-
-
CODE NO:15.26: Demolishing brick tile covering in terraching including stacking of serviceable material and disposal of unserviceable material within 50 metres
65
-
-
CODE NO:17.3.1: Providing and fixing white vitreous china pedestal type water closet (European type) ith seat and lid,10 litre low level white vitreous china flushing cistern & C.P.flush bend with fittings & C.I. brackets , 40 mm flush bend , overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets , cutting and making good the walls and floors wherever required - W.C.pan with ISI marked white solid plastic seat and lid
4
-
-
CODE NO:17.7.2: Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps ,32mm C.P.brass waste of standard pattern , including painting of fittings and brackets ,cutting and making good the walls wherever required - white Vitreous China wash basin size 630x450 mm with a single 15 mm C.P.brass pillar taps
6
-
-
CODE NO:17.32.3: Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6mm thick hard board backing - Oval shape 450x350 mm (outer dimensions)
4
-
-
CODE NO:18.9.11: Providing and fixing ASTM pipes including all ASTM plain& brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fitting with one step ASTM solvent cement and testing of joints complete (Internal work exposed on wall ) - 20mm nominal outer dia pipes
30
-
-
CODE NO:19.33.1: Providing and fixing on wall / column face unplasticed - PVC soil and waste pipes (type - B) conforming to IS : 13592- 1992 including jointing with seal ring conformation to IS : 5382 leaving 10mm gap for thermal expansion - single socked pipes-110mm diametre
23
-
-
CODE NO:19.33.1A: Providing and fixing on wall face/column face unplasticised - PVC moulded fittings / accessories for unplasticisd - PVC soil and waste pipes conforming to IS:14735 - 1999 including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion - Single tee with door - 110x110x110mm
4
-
-
CODE NO:19.33.1C: Providing and fixing on wall face / column face unplasticised - PVC mould fittings / accessories for unplasticisd - PVC soil and waste pipes conforming to IS : 14735 - 1999 including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion - bend 110 mm
4
-
-
CODE NO:19.33.1D: Providing and fixing on wall face / column face unplasticised - PVC mould fittings / accessories for unplasticisd - PVC soil and waste pipes conforming to IS : 14735 - 1999 including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion - bend with door 110
4
-
-
CODE NO:19.33.2: Providing and fixing on wall / column face unplasticised - PVC soil and waste pipes (type B) conforming to IS :13592 - 1992 including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion - Single socketed pipes 75mm diameter
20
-
-
CODE NO:34.1.1: Providing two legged scaffolding using 15cm diameter blue - gum posts or casurina posts or best quality bamboo - posts of 4m over all length (3.0m height + 0.5 m projection + 0.5 into the ground) the distance between the two rows being 1.25 m and the spacing of posts with 0.5 m overlap on either side and braces to step up and providing a platform with country wood planks of 40mm thick and 1m width etc in a complete form using coir and nails 1 m run (Rate of scaffolding for a height of 3 m and lenghth of 1 m)
26
-
-
CODE NO:34.1.2: Exta for Providing two legged scaffolding for every additional height of 2.5 m (Rate for scaffolding for a height of 3 m and length of 1m)
26
-
-
As per observed data: Disposal of scarified building material rate including that of transportation to 2kms lead, loading and unloading etc. complete as directed by Engineer-in-charge.
9.5
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements