Puducherry Adidravidar Development Corporation Limited Tender
View complete overview of Puducherry Puducherry Adidravidar Development Corporation Limited Tender
Puducherry Adidravidar Development Corporation Limited Tender
Civil And Construction
Building Construction
Eprocure
Opening Date25 Jul 2023
Closing Date1 Aug 2023
Tender Amount₹ 13,44,707
Costs
EMD
₹ 26,894Document Cost
₹ 525Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_PADCO_13262_1Bid Award Id
ViewTender No
47/PADSTDC/EW/23-24Tender Authority
Puducherry Adidravidar Development Corporation Limited ViewPurchaser Address
-Website
http://pudutenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Code No.9.129 : Providing and fixing cupboard shutters 25 mm thick , with Pre - laminated flat pressed three layer particle board or graded wood particle board IS : 12823 marked , exterior grade (Grade I Type II) ,having oneside decorative lamination and other side balancing lamination , including teak wood lipping of 25 mm wide x 12 mm thick with necessary screws and bright finished stainless steel piano hinges ,complete
43
-
-
... More
Code No. 10.25.2: Steel work welded in built up sections / framed work , including cutting,hoisting,fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required - in gratings, frames, guard bar, ladder,railings, brackets,gates and similar works
300
-
-
... More
Code No.12.41.2: Providing and fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS :5382, leaving 10mm gap for thermal expansion, (i) Single socketed pipes - 110 mm diameter
64
-
-
... More
Code No.12.42.5.2: Providing and fixing on wall face unplasticised - PVC moulded fittings /accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion - bend 87.5 degree -110 mm bend
16
-
-
... More
Code No.12.42.6.2: Providing and fixing on wall face unplasticised - PVC moulded fittings /accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion - shoe (plain) -110mm shoe
16
-
-
... More
Code No.12.43.2: Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised- PVC rain water pipes by means of 50x50x50mm hard wood plugs ,screwed with M.S. screws of required length, including cutting brickwork and fixing in cement mortar 1:4 ( 1 cement : 4 coarse sand) and making good the wall etc.,complete - 110mm
64
-
-
... More
Code No.13.48.1: Finishing with deluxe multi surface paint system for interiors and exteriors using primer as per manufacture's specification -Two or more coats applied on walls @ 1.25 ltr / 10 sqm over and including one coat of special primer applied @ 0.75 ltr / 10 sqm
3190
-
-
... More
Code No.14.43 : Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to
scrarches etc.complete
3190
-
-
... More
Code No.14.54.1: Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade - One or more coats on old work
513
-
-
... More
Code No. 14.75 : Repair to plaster of thickness 12mm to 20mm in patches of area 2.5sqm and under including cutting the patch in proper shape , raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar , including disposal of rubbish ,all complete
160
-
-
... More
Code No. 15.3 : Demolishing R.C.C work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead
25
-
-
... More
Code No. 15.7.4 : Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead - in cement mortar
38
-
-
... More
Code No. 16.100 : Acid cleaning for the existing Mosaic floors , glazed tiles work and removing the stains and decays to give a glassy look etc complte (The Acid used shall be 32% concentrated hydrochloric acid after taking on the precautionary measures)
232
-
-
... More
Code No. 18.48A : Providing and Placing on terrace (at all litre 7.54 floor levels) polyethylene water storage tank ISI: 12701 marked , with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank - Circular Tank
2000
-
-
... More
Code No. 7259 : Supplying and fixing of C.P.brass long body bibcock
30
-
-
... More
Code No.1.15.1 : Rewiring for light point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface /recessed steel / PVC conduit including dismantling as required - GROUP A
31
-
-
... More
Code No.1.15.2 : Rewiring for light point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface /recessed steel / PVC conduit including dismantling as required - GROUP B
22
-
-
... More
Code No.1.15.3 : Rewiring for light point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface /recessed steel / PVC conduit including dismantling as required - GROUP C
27
-
-
... More
Code No.1.22.2: Supplying and fixing metal box of following sizes (nominal per size) on surface or inrecess with suitable size of phenolic laminated sheet cover in front including painting etc.as required - 100 mm x 100 mm x 60 mm deep
14
-
-
... More
Code No.1.22.6:Supplying and fixing metal box of following sizes (nominal persize) on surface or inrecess with suitable size of phenolic laminated sheet cover in front including painting etc.as required - 200 mm x 125 mm x 60 mm
11
-
-
... More
Code No.1.22.16:Supplying and fixing metal box of following sizes (nominal size) on surface or inrecess with suitable size of phenolic laminated sheet cover in front including painting etc.as required - 250 mm x 300 mm x 100 mm
11
-
-
... More
Code No.1.23.1: Supplying and fixing following piano type switch / socket on the existing switch box / cover including connections etc.as required - 5/6 A switch
116
-
-
... More
Code No.1.23.3 :Supplying and fixing following piano type switch / socket on the existing switch box / cover including connections etc.as required - 2 way 15/16 A switch
16
-
-
... More
Code No.1.25 : Supplying and fixing two module stepped type electronic fan requlator on the existing modular plate switch box including connections but excluding modular plate etc as required
35
-
-
... More
Code No. 1.44 : Installation , testing and commissioning of ceiling fan , including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FRLS PVC insulated , copper conductor ,single core cable etc as required
35
-
-
... More
Code No. 1.50.1: Installation of exhaust fan in the existing opening , including making good the damage , connection , testing ,commissioning etc. as required - Upto 450 mm sweep.
2
-
-
... More
Code No. 2.3.2: Supplying and fixing following way , single pole and neutral ,sheet steel , MCB disribution board , 240 V, on surface / recess , complete with tinned copper bus bar , neutral bus bar , earth bar , din bar , interconnections , powder painted including earthing etc. as required (But without MCB / RCCB / Isolator)
- 8 way ,double door
1
-
-
... More
Code No. 2.10.4 : Supplying and fixing 5 A to 32 A rating , 240/415 V, 10 kA, "C" curve , miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections , testing and commissioning etc .as required. -Triple Pole
10
-
-
... More
Code No. 2.13.2 : Supplying and fixing following rating , double pole , 240 V, Isolator in the existing MCB DB complete with connections ,testing and commissioning etc.as required - 63 A
6
-
-
... More
Code No. 3131-O : Supplying of 450mm 1400 rpm heavy duty exhaust fan Make:Almonard/Orient/Usha.
2
-
-
... More
Code No. NPSR : Suppling of ceiling fan sweep 1200mm Fusion-50 Energy saving fan Five star.Make: Havells (Rate appd No.605/PW/SEI/AE(P)-II/F.No.221/14-15/579 Dt. 02.02.2015)
35
-
-
... More
Code No. NPSR: Supplying and fixing of 20-24 W LED tube light fitting make : Philips/Wipro/Havells (Rate appd No.352/PW/SE-I/AE(P)-I/F.No.CB312(Elect)/2018-19. Dt.30.01.2019)
52
-
-
... More
Code No. NPSR: Supplying and fixing of 48W LED Street Light Fitting(Philips/Havells/Ledgeo) etc., complete as directed by the Engineer-in-charge. (Rate appd No.2735/PW/SE-II/AE(P)-6/SB-150/2022-23/1019 Dt. 25/07/2022).
14
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements