Puducherry Adidravidar Development Corporation Limited Tender

View complete overview of Puducherry Puducherry Adidravidar Development Corporation Limited Tender

Puducherry Adidravidar Development Corporation Limited Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date14 Dec 2022
Closing Date21 Dec 2022
Tender Amount₹ 12,26,870 
Notes
Download

Costs

Summary

Special Repairs And Maintenance Works To The Govt. Girls Hostel At Krishna Nagar, Puducherry

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Code No.4.1.3:- Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plith level - 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)

16

-

-

... More
Code No.4.1.8:- Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plith level - 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size)

38

-

-

... More
Code No.4.5.2:- Providing and fixing upto floor five level precast cement concrete string or lacingcourses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, etc. including hoisting and setting in position withcement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete - 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)

0.25

-

-

... More
Code No.5.1.3:- Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)

6.5

-

-

... More
Code No.5.9.2:- Centering and shuttering including strutting, propping etc and removal of form for - Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

44

-

-

... More
Code No.5.22.7:- Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level – Thermo - Mechanically treated bars (ISI BRAND OF APPROVED MAKE) Fe - 415 or more

675

-

-

... More
Code No.6.4.2:- Brick work with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in superstructure above plinth level upto floor five level in all shapes and sizes in - cement mortar 1:6 ( 1 cement : 6 coarse sand)

0.51

-

-

... More
Code No.11.3.1:- Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps ect. complete - 40mm thick with 20mm nominal size stone aggregate

132

-

-

... More
Code No.11.36A:- Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make (Jhonson / Asian / Somany / Nitco) in all colours, shades of size 200 x 300 mm as approved in skirting , risers of steps and dados, over 12mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement with pigment of matching shade complete – size 200x300 mm

21

-

-

... More
Code No.11.41.2A:- Providing and laying fully vitrified floor tiles of size 600 x600 mm (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622 of approved make (Nitco / Rak / Johnson /Asian ) in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete - size of tile 600 x600 mm

48

-

-

... More
Code No.11.61:- Providing and laying 22 mm thick factory made pre-polished cement concrete flooring tiles of required colour and design over 20 mm thick cement mortar 1:4 (1 cement : 4 sand ) and jointed with cement slurry mixed with an admixture of pigment to match the shade of the tile - (Endura \ Ultra \ Dazzle \ Technic)

79

-

-

... More
Code No.12.20:- Providing and laying pressed clay tiles (as per approved pattern 18mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound, laid over a bed of 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete

86

-

-

... More
Code No.12.41.2:- Providing and fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion, (i) Single socketed pipes - 110 mm diameter

100

-

-

... More
Code No.12.42.4.2:- Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised rigid PVC rain waterpipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion - Single tee without door -110x110x110mm

3

-

-

... More
Code No.12.42.5.2:- Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion - bend 87.5 degree - 110 mm bend

4

-

-

... More
Code No.13.8.3:- 12 mm cement plaster of mix 1:5 (1 cement : 5 fine sand)

85

-

-

... More
Code No.14.1.1:- Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq.metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 metres lead - with cement mortar 1:4 (1 cement : 4fine sand)

13

-

-

... More
Code No.14.43:- Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scrarches etc. complete

1845

-

-

... More
Code No.14.67.2:- Finishing walls with premium acrylic smooth exterior paint with silicon additives of required shade - old work (one or more coats applied @0.83 ltr /10 sqm)

1845

-

-

... More
Code No.14.75A:- Cleaning of terrace / loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5 gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete. (the old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made@ Rs.0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account)

10000

-

-

... More
Code No.15.2.1:- Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead – nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)

5

-

-

... More
Code No.15.2.2:- Nominal concrete 1:4:8 or leaner mix (including equivalent design mix)

4

-

-

... More
Code No.15.7.4:- Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead - in cement mortar

2

-

-

... More
Code No.15.23.1:- Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead – for thickness of tiles 10mm to 25mm

110

-

-

... More
Code No.15.26:- Demolishing brick tile covering in terraching including stacking of serviceable material and disposal of unserviceable material within 50 metres lead

86

-

-

... More
Code No.18.9.12:- Providing and fixing ASTM pipes including all ASTM plain& brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fitting with one step ASTM solvent cement and testing of joints complete (Internal work exposed on wall) - 25mm nominal outer dia pipes

90

-

-

... More
Code No.18.9.13:- Providing and fixing ASTM pipes including all ASTM plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fitting with one step ASTM solvent cement and testing of joints complete (Internal work exposed on wall) - 32mm nominal outer dia pipes

75

-

-

... More
Code No.18.48A:- Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank - Circular Tank

2000

-

-

... More
Code No.18.50.1:- Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms - 15mm nominal bore

6

-

-

... More
Code No.19.30.1.1:- Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I.cover with frame (light duty) 455 x 610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement : 5 fine sand : 10graded stone aggregate 40mm nominal size), inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete extra complete as per standard design - inside dimensions 455 x 610 mm and 45 cm deep for single pipe line - with common burnt clay F.P.S. (non modular) bricks of class designation 7.5

6

-

-

... More
Code No.NPSR:- Chipping the worn out wall and concrete portion using proper tools and removing the loose particles and preparing the surface for treatment with wire bruch etc., complete until to reach good surface and removing the debris and disposal of the debris as directed by the Engineer-in-charge with all leads and lifts etc., complete. (Rate App. Vide No.7677/PW/SE-II/AE(C)6/SB-150/17-18/1152 dt.06.02.2018

224

-

-

... More
Code No.NPSR:- Removing the loose particles/rust/mill scale deposits completely duly cleaning it with wire brush/crush sheet etc., and removing the dust over the old concrete surface and providing and system based aromatic Rust remover of CERA/SIKA/FOSROC/MC Bauchmie/ DON/BASF Or Equivalant make certified and tested by accredited institutions (confirming to IS 9077 - 1979 (reaffirmed - 1997) Appendix B, Clause 5.3.3) including all tools complete as per manufacturers specification and as directed by at the Engineering-in-charge. (Rate App. vide No.7677/PW/SE-II/AE(C)6/SB-150/17-18/1152, dt.06.02.2018).

93

-

-

... More
Code No.NPSR:- Applying a polymer based anticrrosive coating material of CERA/SIKA/ FOSROC/MC Bauchine/DON/ BASF or Equivalent make certified and testing by accredited institutions mixing mechanically until it is homogeneous and applying the same as one rich coat on prepared steel surface with brush with all lead and lift etc., complete and as directed by the Engineering-in-charge (Measurement as per the total area of treatment) (Rate App. vide No.7677/PW/SE-II/AE(C)6/SB-150/17-18/1152 dt.06.02.2018).

163

-

-

... More
Code No.NPSR:- Plastering the wall surface with cement mortar of mix 1:4 (one part of cement : 4 fine sand) mixed with styrene butadiene styrene rubber latex of CERA/ SIKA/ FOSROC/ MC Bauchmie/ DON/ BASF or Equivalent make certified and tested by accredited institutions (confirming to ASTM 1059-99 for bonding agent, Physical properties: Compressive strength 7.5 + or -2.0MPa, Tensile strength 2.0MPa at the ratio of 1:1:5 (1 part of cera polymer Latex : 1 part of water : 5 parts of cement) in 2 coats including all lead and lift etc. complete as per manufacturer's specification and as directed by the Engineer-in-charge. (Rate App. vide No.7677/PW/SE-II/AE(C)6/SB-150/17-18/1152 dt.06.02.2018).

163

-

-

... More
Code No.31.9.1:- Providing and fixing brass gate valve with C.I. wheel of approved quality (screwed end) - 32mm nominal bore.

3

-

-

... More
Code No.NPSR:- Supplying and fixing of 20-24W tube light fitting. Make: Philips

25

-

-

... More
Code No.NPSR:- Supplying of ceiling fan sweep 1200mm fusion-50 energy saving fan five star. Make Havells. Rate App. Lr. No.605/PW/SE-I/AE(P)-II/F.No.221/2014-15 dt.02.02.2015

10

-

-

... More
Code No.1.44:- Installation, testing and commissioning of ceiling fan, per no including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc as required.

10

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.