Public Works Department Tender
View complete overview of Puducherry PWD Tender
Public Works Department - PWD Tender
Civil And Construction
Building Construction
Eprocure
Opening Date13 Dec 2023
Closing Date26 Dec 2023
Tender Amount₹ 13,08,457
Costs
EMD
₹ 26,169Document Cost
₹ 525Tender Fee
Refer Documents
Summary
Construction Of Workshop For Mechanical Engineering Department And Completion Of Balance Portion Of Lower Level Floor At South Block Of Indira Gandhi Polytechnic College, Mahe.
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_PWDC2_14552_1Bid Award Id
ViewTender No
73/EEM/23-24/29(23-24)Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://https://pwd.py.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Sample Affidavit and experience for PWD Puducherry Contractor
BOQ Items
... More
Code No.1.27.6:- Supplying and fixing following size / modules , GI box per alongwith modular base & cover plate for modular switches inrecess etc. as required - 12 module (125 mm x 125 mm)
9
-
-
... More
Code No. 1.33:-Supplying and fixing 3 pin , 5 A ceiling rose on the existing per junction box / wooden block including connection etc asrequired
50
-
-
... More
Code No. 1.14.2:- Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor , single core cable in surface / recessed medium class PVC conduit as required - 2 X 2.5 sq.mm + 1 x 2.5 sq.mm earth
456
-
-
... More
Code No. 1.14.3:- Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor , single core cable in surface / recessed medium class PVC conduit as required - 2 X 4 sq.mm + 1 x 4 sq.mm earth wire
410
-
-
... More
Code No. 1.14.9:- Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor ,single core cable in surface / recessed medium class PVC conduit as required - 4 X 6 sq.mm + 2 x 6 sq.mm earth wire
319
-
-
... More
Code No. 1.17.1:-Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface / recessed steel / PVC conduit as required - 1 X 1.5
1950
-
-
... More
Code No. Non PSR:- Supplying and installation, testing and commissioning of surface/ recess mounting, vertical type 415 volts, TPN MCCB Distribution board of sheet steel, dust protected,duly phosphatised and powedered painted, inclusive of 200 amps tinned copper bus bar, 2 Nos of neutral link, earth eearth bar, din bar for mounting MCCB's detachable gland/knock out place of following ways (But without MCCB) a required make: Legrand , 6 way, TPN double door MCCB, DB, Vertical type including 6 mm dia rag bolts with nuts
3
-
-
... More
Code No. 2.4.1:- Supplying and fixing following way , horizontal type three pole per and neutral , sheet steel , MCB distribution board , 415 V, on surface / recess , complete with tinned copper bus bar , neutral bus bar , earth bar , din bar, Interconnections , powder painted including earthing etc. as required (but without MCB / RCCB / Isolator ) 4way (4+12) , double door
2
-
-
... More
Code No. 2.10.1:- Supplying and fixing 5 A to 32 A rating , 240/415 V, 10 kA, per "C" curve , miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections , testing and commissioning etc .as required. -Single Pole
24
-
-
... More
Code No. Non PSR:- Supplying and fixing following rating, three pole 415 V miniature circuit breaker in the existing MCB DB complete with connection , testing and commisioning etc., as required 63 A Make : Legrand Polycab/Sncab
13
-
-
... More
Code No. 1.24.1:- Supplying and fixing following modular switch / socket on the per existing modular plate & switch box including connections but excluding modular plate etc. as required - 5/6 A switch
86
-
-
... More
Code No. 1.24.4:- Supplying and fixing following modular switch / socket on the per existing modular plate & switch box including connections but excluding modular plate etc. as required - 3 pin 5/6 A socket outlet
9
-
-
... More
Code No. 1.24.3:- Supplying and fixing following modular switch / socket on the per existing modular plate & switch box including connections but excluding modular plate etc. as required - 15/16 A switch
10
-
-
... More
Code No. 1227 :- Supply of AC Exhaust Fan 375mm (15'') Sweep (Light Duty)
5
-
-
... More
Code No. 1207 :- Supply of 48W LED Street Light Fitting(Philips / Havells )
5
-
-
... More
Code No.17.2.12:- Supply and fixing of wall mount bracket of 50 mm dia GI pipe per suitable for SVL / MH fittings with clamp , bolts and nuts as required
5
-
-
... More
Code No. 17.2.11:- Fixing testing and commissioning of Sodium vapour / Mercury per vapour / Metal halide street light fittings on existing poles as required
5
-
-
... More
Code No. 1.45:- Installation , testing and commissioning of ceiling fan , per including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FRLS PVC insulated , copper conductor , single core cable , including providing and fixing phenoliclaminated sheet cover on the fan box etc as required
20
-
-
... More
Code No. 1.50.1:- Installation of exhaust fan in the existing opening , including per making good the damage , connection , testing ,commissioning etc. as required - Upto 450 mm sweep
5
-
-
... More
Code No. Non PSR:- Supply and fixing of 20-24W LED tube light fitting Make Philips/Havells/Wipro
42
-
-
... More
Code No. Non PSR: - Supplying of 3 1/2 x 95 Sqmm armoured aluminium UG cable 1.1 KV grade at site . Make : Polycab / Finolex /Havells.
180
-
-
... More
Copde No. Non PSR:- Supplying of 4 x 50 sq.mm armoured aluminium UG cable 1-1 KV grade at site. Make Polycab /Finolex Havells.
150
-
-
... More
Code No. 7.1.2:- Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation , sand cushioning, protective covering and refilling the trench etc.as required - above 35 sq.mm and upto 95 sq.mm
165
-
-
... More
Code No. 7.7.2:- Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required - above 35 sq.mm and upto 95 sq.mm (clamped with 25 x3mm MS flat clamp)
150
-
-
... More
Code No. 9.1.24:- Supplying and making end termination with brass compression per gland and aluminium lugs for following size of PVC insulatedand PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required - 31/2 X95 sq.mm (45 mm
2
-
-
... More
Code No.9.1.36:- Supplying and making end termination with brass compression pergland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1kV grade as required - 4 X50 sq.mm (35 mm)
6
-
-
... More
Code No. Non PSR: Supplying of energy efficient 5 star 1200 mm sweep AC ceilling fan complete with all accessories like down rod, canopy etc., with ,aking necessarry connection cable as requird etc. (Make : Orient/USHA/Crompton/ Havells/or equivalent)
20
-
-
... More
Code No. 31.263.1:- Making earth pit of G.I. pipe for earthing in earth pit with 40mm dia. G.I. pipe medium class of length 3.05m perforated with 46 Nos of 12mm dia. holes, pipe lowered in bore holes of 150mm dia. and filled in with charcoal and salt in alternative layer of 300mm, the top of G.I. pipe shall be clamped. Earth pit shall be provided with 60cm dia precast ring with 60cm depth alround,covered with R.C.C. precast slab etc. as per I.E. standards.
8
-
-
... More
Code No. 31.264.1A:- Supplying and fixing of copper wire 8 SWG (4 mm dia) for earthing arrangements including bolt and nuts etc., complete.
96
-
-
... More
Code No. 2834:- Supply of 100 mm dia G.I.pipe (medium class)
12
-
-
... More
Code No. Non PSR:- Supply erection, testing and commissioning of one number of distribution panel board for the power supply of overall size 1375 x 1750 x 300mm made out of 16 EWG thich cold rolled MS sheet. The panel has to be mounted on MS angle frame fixed suitably on the wall of 1 no. of 250 A, 4 pole change over, 1 no. of 125 A TPN cubicle switch fuse units make : L&T, 3 nos. of 100 A TPN cubicle switch fuse units make: L&T, 2 nos. of 63 A TPN cubicle switch fuse units make: L&T, 3 nos of current transformer, 1 no. of digital ammeter, 1 no. of digital voltmeter, 3 nos of signal lamps, 2 nos of selector switch units. The switch units are to be fixed within the allotted size in the panel board, the bottom sheet for cable entry. Inter connection between the switch fuse units are to be done with copper flats. The panel should be painted with two coats of rust froof zinc chromate and two coats of anti corrosive epoxy shade 631 siemens grey paint after completion of de rusting process. The door should be of flush type in position. The panel provided with removable type gland plated to the bottom and with sufficient holes of required diameter, the cost should be inclusive of minor modifications suitable for site condition as approved by Engineer -in Charge.
1
-
-
... More
Code No. 2.20:- Supplying and fixing 30 A, 415 V, TPN Industrial type socket per outlet, with 4 pole and earth , metal enclosed plug top alongwith 30A "C" curve, TPMCB in sheet steel enclosure ,on surface or in recess , with chained metal cover for the socket out let and complete with connections , testing and commissioning ets as required
17
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements