Public Works Department Tender
View complete overview of Puducherry PWD Tender
Public Works Department - PWD Tender
Civil And Construction
Building Construction
Eprocure
Opening Date31 Jul 2024
Closing Date12 Aug 2024
Tender Amount₹ 47,23,423
Costs
EMD
₹ 94,468Document Cost
₹ 525Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PWDC2_16215_1Bid Award Id
ViewTender No
10/PW/SBD-II/ 2024-25Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://pudutenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Supplying and filling with gravel (excluding rock) in layers not exceeding 20cm in depth , breaking clods, watering , rolling each layer with 1/2 tonne roller , or wooden or steel rammers , including all leads and lift etc., complete for making play fields , running trees and court yards
6
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plith level - 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size)
0.5
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plith level - 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)
1
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plith level - 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size)
1.5
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plinth level - 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size)
11.5
-
-
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacture's specification.
16
-
-
Centering and shuttering including strutting , propping etc and removal of form for - Suspended floors , roofs , landings , balconies and access platform
6
-
-
Centering and shuttering including strutting , propping etc and removal of form for - Lintels , beams , plinth beams , girders , bressumers and cantilevers.
155
-
-
Centering and shuttering including strutting , propping etc and removal of form for - Columns , Pillars , Piers , Abutments , Posts and Struts.
120
-
-
Centering and shuttering including strutting , propping etc and removal of form for -Weather shade , Chajjas, corbels etc., including edges.
45
-
-
Providing , hoisting and fixing upto floor five level precast reinforced cement concrete in shelves including setting in cement mortar 1:3 (1 cement : 3 coarse sand) , cost of required centering , shuttering and finishing with neat cement punning on exposed surfaces but excluding the cost of reinforcement , with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size)
0.05
-
-
Providing precast cement concrete jali 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 6mm nominal size) reinforced with 1.6 mm dia mild steel wire including centering and shuttering, roughening cleaning , fixing and finishing in cement mortar 1:3 ( 1 cement : 3 fine sand) etc. complete excluding plastering of the jambs, sills and soffits - 50mm thick.
6
-
-
Steel reinforcement for R.C.C.work including straightening , cutting , bending , placing in position and binding all complete upto plinth level - Thermo -Mechanically treated bars (ISI BRAND OF APPROVED MAKE) Fe - 415 or more
5460
-
-
Steel reinforcement for R.C.C.work including straightening , cutting , bending , placing in position and binding all complete above plinth level - Thermo - Mechanically Treated bars (ISI BRAND OF APPROVED MAKE) Fe - 415 or more.
1560
-
-
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering , shuttering , finishing and reinforcement - All work upto plinth level 1:1.5:3 (1cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size).
20
-
-
Reinforced cement concrete work in walls (any thickness) , including attached pilasters, buttresses , plinth and sting courses , fillets , columns , pillars , piers , abutments , posts and struts etc. upto floor five level excluding cost of centering , shuttering , finishing and reinforcement - 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size)
5
-
-
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15 degree landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral stair cases upto floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement: 1.5 coarse M sand : 3 graded stone aggregate 20mm nominal size)
10
-
-
Brick work with common burnt clay F.P.S. (non modular ) bricks of class designation 3.5 in foundation and plinth in - cement mortar 1:4 (1 cement : 4 coarse sand)
5.5
-
-
Brick work with common burnt clay F.P.S. (non modular ) bricks of class designation 3.5 in foundation and plinth in - cement mortar 1:6 (1 cement : 6 coarse sand)
32
-
-
Brick work with common burnt clay F.P.S (non modular ) bricks of class designation 3.5 in superstructure above plinth level upto floor five level in all shapes and sizes in - cement mortar 1:6 ( 1 cement : 6 coarse sand)
45
-
-
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 3.5 in foundations and plinth in - cement mortar 1:4 (1 cement :4 coarse sand)
11
-
-
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 3.5 in superstructure above plinth level upto floor V level - cement mortar 1:4 (1 cement : 4 coarse sand)
5.5
-
-
Extra for providing and placing in position 2 nos 6mm dia M.S.bars at every third course of half brick masonry
16.5
-
-
Providing and fixing M.S.grills of required pattern in frames of windows etc with M.S. flats , square or round bars etc. including priming coat with approved steel primer all complete - Fixed to steel windows by welding
200
-
-
Providing and fixing M.S.grills of required pattern in frames of windows etc with M.S. flats , square or round bars etc. including priming coat with approved steel primer all complete - Fixed to openings / wooden frames with rawl plugs screws etc
1100
-
-
Providing and fixing of 65mm Godrej Navatal lock of 6 levers etc complete.
3
-
-
Providing and fixing 1mm thick M.S.sheet door with frame of 40x40x6 mm angle iron and 3mm M.S.gusset plates at the junctions and corners , all necessary fittings complete, including applying a priming coat of approved steel primer - Using flats 30x6 mm for diagonal braces and central cross piece.
13
-
-
Steel work welded in built up sections / framed work , including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required – in gratings, frames, guard bar, ladder, railings, brackets,gates and similar works.
1000
-
-
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc .complete - 40mm thick with 20mm nominal size stone aggregate
330
-
-
Cement plaster skirting upto 30 cm height , with cement mortar 1:3 (1 cement : 3 coarse sand) , finished with a floating coat of neat cement - 18mm thick.
35
-
-
Providing and laying pressed clay tiles (as per approved pattern 18mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound , laid over a bed of 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete
180
-
-
Lime concrete terracing on roofs of required thickness laid to fall with 25mm nominal size brick aggregate and 50% lime mortar 1:2 (1 lime putty : 2 surkhi) rammed and finished with gur and belgiri treatment complete including rounding of junctions with Parapet wall complete.
18
-
-
Making khurras 45x45cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20mm nominal size) over P.V.C. sheet 1m x1m x 400 micron , finished with 12 mm cement plaster 1:3 ( 1cement : 3 coarse sand) and a coat of neat cement , rounding the edges, making and finishing the outlet complete.
4
-
-
Providing and fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion, (i) Single socketed pipes – 110 mm diameter.
35
-
-
Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion - Single tee without door -110x110x110mm.
4
-
-
Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion - bend 87.5 degree - 110 mm bend.
4
-
-
Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion - shoe (plain) - 110mm shoe.
4
-
-
Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised- PVC rain water pipes by means of 50x50x50mm hard wood plugs , screwed with M.S. screws of required length, including cutting brickwork and fixing in cement mortar 1:4 ( 1 cement : 4 coarse sand) and making good the wall etc., complete - 110mm
31
-
-
20mm cement plaster of mix -1:4 (1 cement : 4 fine sand).
1430
-
-
15mm cement plaster on rough side of single or half brick wall of mix - 1:4 (1 cement : 4 coarse sand)
9
-
-
12 mm cement plaster of mix 1:5 (1 cement : 5 fine sand)
365
-
-
Cement plaster 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement - 20mm cement plaster
21
-
-
15 mm cement plaster on the rough side of single or half brick wall of mix 1:5 (1 cement : 5 fine sand)
430
-
-
6mm cement plaster of mix 1:3 (1 cement : 3 fine sand).
331
-
-
Finishing with deluxe multi surface paint system for interiors and exteriors using primer as per manufacture's specification - Two or more coats applied on walls @ 1.25 ltr / 10 sqm over and including one coat of special primer applied @ 0.75 ltr / 10 sqm.
3210
-
-
Painting with synthetic enamel paint of approved brand and manufacutre to give an even shade – Two or more coats on new work.
150
-
-
Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq.metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 metres lead – with cement mortar 1:4 (1 cement : 4fine sand)
15
-
-
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc.complete
130
-
-
Demolishing lime concrete manually / by mechanical means and disposal of material within 50 metres.
15.5
-
-
Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead - nominal concrete 1:3:6 or richer mix (i/c equivalent design mix).
13.5
-
-
Demolishing R.C.C work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead.
3
-
-
Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead - in cement mortar.
91
-
-
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead - of area 3 sqm and below.
17
-
-
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead - of area beyond 3 sq.metres.
3
-
-
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead - for thickness of tiles 10mm to 25mm.
175
-
-
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
1430
-
-
Supplying fixing and commisioning of Suguna / Texmo / Sharp 1 HP monoblock pumpset slow speed single phase motor. The rate include the cost of pumpset , pumpset fixing in position and test run etc.complete.
1
-
-
Providing and fixing ASTM pipes including all ASTM plain& brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing . This includes jointing of pipes & fitting with one step ASTM solvent cement and testing of joints complete (Internal work exposed on wall ) - 20mm nominal outer dia pipes.
20
-
-
Providing and fixing ASTM pipes including all ASTM plain& brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing . This includes jointing of pipes & fitting with one step ASTM solvent cement and testing of joints complete (Internal work exposed on wall ) - 25mm nominal outer dia pipes.
20
-
-
Providing and fixing ASTM pipes including all ASTM plain& brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing . This includes jointing of pipes & fitting with one step ASTM solvent cement and testing of joints complete (Internal work exposed on wall ) - 32mm nominal outer dia pipes
20
-
-
Providing and fixing ASTM pipes including all ASTM plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes & fitting with one step ASTM solvent cement and the cost of cutting chases and making good the same including testing of joints complete (Concealed work including cutting chases and making good the walls etc.) – 20 mm nominal outer dia pipes.
10
-
-
Providing and fixing gun metal gate valve with C.I.wheel of approved quality (Screwed end) - 25mm nominal bore.
8
-
-
Providing and fixing gun metal gate valve with C.I.wheel of approved quality (Screwed end) - 40mm nominal bore.
1
-
-
Providing and fixing ball valve (brass) of approved quality , high or low pressure , with plastic floats complete - 25mm nominal bore
1
-
-
Providing and fixing G.I.union in G.I.pipe including cutting and threading the pipe and making long screws etc.complete (New work) - 25mm nominal bore
6
-
-
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI: 12701 marked , with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank - Circular Tank.
2000
-
-
Providing and fixing C.P.brass stop cock (concealed ) of standard design and of approved make conforming to IS :8931 – 15mm nominal bore.
6
-
-
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality - LD - 2.5 - rectangular shape 600x450 mm inernal dimensions
1
-
-
Boring , providing and installing bored cast -in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring , with bentonite solution and temporary casing of appropriate lenghth for setting out and removal of same and the lenghth of the pile to be embedded in the pile cap etc. all complete , including removal of excavated earth with all lifts and leads (length of pile for payment shall be measured upto bottom of pile cap) - 300 mm dia piles.
160
-
-
Chipping of unsound / weak concrete material from slabs , beams , columns etc. with manual Chisel and / or by standard power driven percussion type or of approved make including tapering of all edges , making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete - 50 mm average thickness.
130
-
-
Chipping of unsound / weak concrete material from slabs , beams , columns etc. with manual Chisel and / or by standard power driven percussion type or of approved make including tapering of all edges , making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete - 25 mm average thickness
330
-
-
Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm upto 200mm in RCC beams , lintels , columns and slabs to introduce steel bars for sunshades / balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement , all complete - Upto and including 12mm dia.
455
-
-
Providing , mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and complete in all respect - SBR Polymer ( @ 10% of cement weight ) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer.
460
-
-
Providing , mixing and applying SBR polymer (of approved make ) modified Cement mortar in proportion of 1:4 (1 cement : 4 graded coarse sand with polymer minimum 2% by wt.of cement used) as per specifications . Note: Measurement and Payment : The Pre-measurement of thickness shall be done just after the surface preparation is completed and payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and / or the 75mm size cube cursing strength at the end of 28 days to be not less than 30 N / Sqmm) - 25 mm average thickness in two layers.
330
-
-
Providing , mixing and applying SBR polymer (of approved make @ minimum 2% by wt.of cement used) modified plain / reinforced cement concrete for structural members having minimum characteristic compressive strength ( with ordinary portland cement , coarese sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria) with specified average thickness . Note: Rates shall be for finished surface area of concrete and shall include the cost of labour , concrete and appropriate approved Super - Plasticiser for rendering concrete as flowable and SBR polymer but shall exclude cost of reinforcement , bond coat , Shear Keys , centering and shuttering , strutting , propping etc., (Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal istrument) - 50 mm thick in Grade M 25 with cement content not less than 330 kg per cum
130
-
-
Supply of Quarry rubbish including stacking to department gauge for premeasurement and spreading required thickness.
11
-
-
Providing and fixing welded steel windows of standard rolled steel section, joints mitred and welded with 15x3 mm lugs, 10 cm long with steel lugs embedded in cement concrete blocks 15x10x10cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or wooden plugs and screws or with fixing clips or with fixing Bolts and nuts as required including fixing and welding of M.S. sheet of 1.20mm thick with M.S. flat beading welded around the panels welding of hinges, handles, tower bolts, hooks and eyes including the cost of applying a priming coat with ready mixed red oxide zinc chromate primer of approved brand and manufacture etc. complete window side hung/top hung
550
-
-
Disposal of Moorum / building rubbish / similar unserviceable dismantled or waste material by mechanical transport including loading, transporting unloading within a lead of 10km for all lifts, complete all as per the directions of Engineer-in-charge.
170
-
-