Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PWDC2_16272_1Tender No
20/EEM/24-25/14(24-25)Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://https://pwd.py.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Code No. 2.5.3:- Supplying and fixing following way , single pole and neutral , sheet steel , MCB disribution board , 240 V, on surface / recess , complete with tinned copper bus bar , neutral bus bar , earth bar , din bar , interconnections , powder painted including earthing etc. as required (But without MCB / RCCB / Isolator)-12 way (4+36) , double door.
1
-
-
Code No. 1.3.3:- Wiring for light point / fan point /exhaust fan point /call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit , with modular switch , modular plate , suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required - GROUP C
40
-
-
Code No. 1.4:- Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit , 2 way modular switch , modular plate , suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc.as required.
10
-
-
Code No. 1.27.2:- Supplying and fixing following size / modules , GI boxalongwith modular base & cover plate for modular switches in recess etc. as required - 3 module.
18
-
-
Code No. Non PSR:- Supply and fixing following rating, three pole, 415 V miniature circuit breaker in the existing MCB DB complete with connection , testing and commissioning etc., as required -63 A Make : Legrand/ Polycab/ Sncab.
9
-
-
Code No. 2.101:- Supplying and fixing 5 A to 32 A rating , 240/415 V, 10 kA, C curve , miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections , testing and commissioning etc .as required. -Single Pole
10
-
-
Code No. 2.14.2:- Supplying and fixing following rating, double pole , (single phase and neutral), 240V , residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections , testing and commissioning etc as required - 40 A
10
-
-
Code No. 2.15.2:- Supplying and fixing following rating , four pole ,(three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections , testing and commissioning etc.as required - 40 A.
3
-
-
Code No. 2.17:- Supplying and fixing following rating , four pole ,(three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections , testing and commissioning etc.as required - 40 A.
6
-
-
Code No1.14.3:- Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor , single core cable in surface / recessed medium class PVC conduit as required - 2 X 4.0 sq.mm + 1 x 4.0 sq.mm earth.
245
-
-
Code No. 1.14.2:- Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor , single core cable in surface / recessed medium class PVC conduit as required - 2 X 2.5 sq.mm + 1 x 2.5 sq.mm earth.
340
-
-
Code No. 1.14.1:-Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor , single core cable in surface / recessed medium class PVC conduit as required - 2 X 1.5 sq.mm + 1 x 1.5 sq.mm earth.
420
-
-
Code No. 1.32:- Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess , including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/6 A modular switch , connections etc , as required
4
-
-
Code No. 1.56:-Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess , including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlets and 2 nos. 5/6 A modular switches , connection etc.as required. (For light plugs to be used in non residential buildings).
4
-
-
Code No. 1.57:- Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB , "C" curve including connections , painting etc .as required.
2
-
-
Code No. Non PSR:- Supply and fixing of 20 - 24W LED tube light fitting. Make:- Philips / Havells / Wipro. Rate APP.Lr.No.352/PW/SE-I/AE(P)-I/F.No.CB-312(Elec)/18-19/dt.30-01-2019.
15
-
-
Code No. Non PSR:- Supplying of energy efficient 5-star 1200 mm sweep Ac ceiling fan complete with all accesories like down rod, canopy etc with making necesary connection cable a required etc. ( Make : Orient/ Usha/ Crompton/ Havell/ or equivalent).
12
-
-
Code No 1.45:- Installation , testing and commissioning of ceiling fan , including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FRLS PVC insulated , copper conductor , single core cable , including providing and fixing phenolic laminated sheet cover on the fan box etc as required
12
-
-
Code No. Non PSR :- Supply and fixing of 20-24W slim type recess mounted square LED luminaire of size 1'X1'/1.25'x1.25". Make:Wipro/ Jaquar /Philips
12
-
-
Code No. 31.263.1:-Making earth pit of G.I. pipe for earthing in earth pit with 40mm dia. G.I. pipe medium class of length 3.05m perforated with 46 Nos of 12mm dia. holes, pipe lowered in bore holes of 150mm dia. and filled in with charcoal and salt in alternative layer of 300mm, the top of G.I. pipe shall be clamped. Earth pit shall be provided with 60cm dia precast ring with 60cm depth alround,covered with R.C.C. precast slab etc. as per I.E. standards.
2
-
-
Code No. 5.13:- Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15mm dia G.I.pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
40
-
-
Code No. 5.10:- Providing and fixing 25 mm x 5 mm copper strip in 40 mm dia G.I.pipe from earth electrode including connection with brass nut , bolt, spring , washer excavation and re-filling etc.as required
20
-
-
Code No. Non PSR:-Supply of 3.5 x 35 sq.mm PVC/XLPE sheathed armoured aluminum UG cable - 1.1 KV grade. Make : Finolex/ Polycab/ Paragon/ Havells.
60
-
-
Code No. Non PSR:- Supplying of 4 x 16 sqmm armoured aluminium U.G cable - 1.1 KV grade at site. Make:- Polycab/Finolex/Havells. (Appr. Lr. No. 1681/PW / SE-II/ AE (P)-6/ SB-868/ 2022-23 / 1679, dt. 24.06.2022)
80
-
-
Code No. Non PSR:-Supply of 4 x10 sq.mm PVC sheathed armoured aluminum UG cable - 1.1 KV grade. Make : Finolex/ Polycab/ Paragon.
50
-
-
Code No. 7.1.1:- Laying of one number PVC insulated and PVC sheathed / metre 361.21 XLPE power cable of 1.1 kV grade of following size direct in ground including excavation , sand cushioning, protective covering and refilling the trench etc.as required - upto 35 sq.mm.
170
-
-
Code No. 9.1.33:- Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1KV grade as required:4 X 16 Sq.mm (28mm)
20
-
-
Code No. Non PSR:-Supplying and laying D-Link CAT-6 wire, channel & other accessories for networking. The cost includes all taxes, labour charges, materials , transportation etc., complete.
170
-
-
Code No. Non PSR:-Supplying and fixing Legrand back box face plate, CAT 6 IO & RJ11 IO for networking and intercom. The rate includes all taxes.
16
-
-
Code No. Non PSR:-Supplying and laying 2 pair wire with channel & other accessories . The cost includes all taxes, labour charges, materials , transportation etc., complete.
50
-
-
Code No. Non PSR:-Supplying and fixing of D-Link 24 port switch-Giga for networking. The rate includes all taxes.
2
-
-
Code No. Non PSR:-Supplying and fixing of D-Link patch panel 24 port for networking. The rate includes all taxes.
2
-
-
Code No. Non PSR:-Supplying and fixing of 125 /200/250/315 A DIN HRC fuse base for aerial board in the ED pole for control the metering panel supply. Make : HPL/ Havells/ C&S. cost should be inclusive of minor modification suitable for site condition etc., complete as approved by Engineer - In Charge.
6
-
-
Code No. Non PSR:-Supplying and fixing of 32-100 A HRC fuse link for fuse base in the Aerial board. Cost should be inclusive of minor modification suitable for site condition etc., complete as approved by Engineer - In Charge.
6
-
-
Code No. 3131-O:- Supply of 375 mm 1400 rpm heavy duty exhuast fan Make : Almonard/ Orient/ Usha. 3000
4
-
-
Code No 1.50.1:-Installation of exhaust fan in the existing opening , including making good the damage , connection , testing , commissioning etc. as required - Upto 450 mm sweep