Public Works Department Tender
View complete overview of Puducherry PWD Tender
Public Works Department - PWD Tender
Security and Emergency Services
Electrical and Electronics
Electrical Works
Eprocure
Opening Date22 Nov 2024
Closing Soon28 Nov 2024
Tender Amount₹ 14,61,422
Costs
EMD
₹ 29,228Document Cost
₹ 525Tender Fee
Refer Documents
Summary
Rewiring And Providing Cctv Arrangement 30kva 24 Kw Generator Set Air Cooled Facility In Ground Floor Sub Jail Premises And Rewiring At First Floor Quarters At Administrative Office Building, Sub Jail, Mahe.
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PWDC2_16946_1Tender No
35/EEM/24-25/27(24-25)Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://https://pwd.py.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Code No. 1.14.3: Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor , single core cable in surface / recessed medium class PVC conduit as required - 2 X 4 sq.mm + 1 x 4 sq.mm earth wire
35
-
-
Code No. 1.14.9: Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor , single core cable in surface / recessed medium class PVC conduit as required - 4 X 6 sq.mm + 2 x 6 sq.mm earth wire
40
-
-
Code No. 1756: 8 way (4+24) , TPN , MCB DB , double door ,horizontal type
2
-
-
Code No. 2.2.13: Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel borad including drilling holes in cubicls panels , making connections , etc. as required - 100 A , 30 kA 4 pole
1
-
-
Code No. 2.14.3: Supplying and fixing following rating, double pole , (single phase and neutral), 240V , residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections , testing and commissioning etc as required-63 A
3
-
-
Code No. 2.4.1: Supplying and fixing following way , horizontal type three pole and neutral , sheet steel , MCB distribution board , 415 V, on surface / recess , complete with tinned copper bus bar , neutral bus bar , earth bar , din bar, Interconnections , powder painted including earthing etc. as required (but without MCB / RCCB/ Isolator ) 4way (4+12) , double door
1
-
-
Code No. 2.10.1:- Supplying and fixing 5 A to 32 A rating , 240/415 V, 10 kA,"C" curve , miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections , testing and commissioning etc .as required. -Single Pole
60
-
-
Code No.1.27.2: Supplying and fixing following size / modules , GI box alongwith modular base & cover plate for modular switches in recess etc. as required - 3 module (100mm x 75mm)
2
-
-
Code No.1.27.3: Supplying and fixing following size / modules , GI box alongwith modular base & cover plate for modular switches in recess etc. as required -4 module (125 mm x 75 mm)
2
-
-
Code No. 1.27.4: Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc.as required - 6 module (200 mm x 75 mm)
2
-
-
Code No. 1.27.5: Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc.as required - 12 module (125 mm x 125 mm)
9
-
-
Code No. 1.24.1: Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required - 5/6 A switch
57
-
-
Code No. 1.24.4: Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required - 3 pin 5/6 A socket outlet
5
-
-
Code No. 1.56: Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess , including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlets and 2 nos. 5/6 A modular switches , connection etc.as required. (For light plugs to be used in non residential buildings)
6
-
-
Code No. 1.32: Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess , including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/6 A modular switch , connections etc , as required
2
-
-
Code No. 1.33: Supplying and fixing 3 pin , 5 A ceiling rose on the existing junction box / wooden block including connection etc as required.
35
-
-
Civil PSR Code No.31.263.1 Making earth pit of G.I. pipe for earthing in earth pit with 40mm dia. G.I. pipe medium class of length 3.05m perforated with 46 Nos of 12mm dia. holes, pipe lowered in bore holes of 150mm dia. and filled in with charcoal and salt in alternative layer of 300mm, the top of G.I. pipe shall be clamped. Earth pit shall be provided with 60cm dia precast ring with 60cm depth alround,covered with R.C.C. precast slab etc. as per I.E. standards.
2
-
-
Civil PSR Code No.31.264.1A Supplying and fixing of copper wire 8 SWG (4 mm dia) for earthing arrangements including bolt and nuts etc., complete.
40
-
-
Code No.NPSR:- Supply and fixing of 20 - 24W LED tube light fitting. (Make:-Havells/Crompton/Bajaj /Halonix/Surya) (Inclusive of GST)
40
-
-
Code No.NPSR:- Supply and fixing of 1200 mm BEE 5-star rated BLDC ceiling fan. Make: Atomberg/ Havells/ Bajaj/ Orient/ Crompton / Usha. (Inclusive of GST)
12
-
-
Code No.1.57:- Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB , "C" curve including connections , painting etc .as req.
40
-
-
Code No.NPSR:-Supply of ISI marked 4x25sqmm armoured aluminium PVC U.G cable - 1.1 KV grade. Make:- Finolex/ Polycab/Havells.(Inclusive of GST)
12
-
-
Code No.7.1.1:- Laying of one number PVC insulated and PVC sheathed /XLPE power cable of 1.1 kV grade of following size direct in ground including excavation , sand cushioning, protective covering and refilling the trench etc.as required - Upto 35 sq.mm
1
-
-
Code No.9.1.34 :- Supplying and making end termination with brass compression
gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1kV grade as required - 4 X25 sq.mm (28 mm)
25
-
-
Code No. NPSR: Supply and fixing of LED street light fitting existing/ New street light arms having 140Watts -160W and above (system wattage), IP 65/66, white colour with necessary over voltage, under voltage and surge protection with 3 years onsite warranty for replacement/ rectification. (Make:-Philips/ Havells / Crompton/ Bajaj/ Eveready)The rate is inclusive of all taxes.
20
-
-
Code No.17.2.12: Supply and fixing of wall mount bracket of 50 mm dia GI pipe suitable for SVL / MH fittings with clamp , bolts and nuts as required
2
-
-
Code No. NPSR: Supply and fixing of LED street light fitting existing/ New street light arms having 140Watts -160W and above (system wattage), IP 65/66, white colour with necessary over voltage, under voltage and surge protection with 3 years onsite warranty for replacement/ rectification. (Make:-Philips/ Havells / Crompton/ Bajaj/ Eveready)The rate is inclusive of all taxes.
9
-
-
Code No.17.2.12: Supply and fixing of wall mount bracket of 50 mm dia GI pipe suitable for SVL / MH fittings with clamp , bolts and nuts as required
9
-
-
Code No.17.2.11 Fixing testing and commissioning of Sodium vapour / Mercury vapour /Metal halide street light fittings on existing poles as required
9
-
-
Code No. NPSR: Supply of 32 channel network video recorder.
#) Support Multi - brand network cameras.
#) Support 4 SATA HDDs upto 16TB, 2USB2.0 with MAF letter of Make CP plus CP - UNR 432T4,Samsung, Sony. (Inclusive of GST)
1
-
-
Code No. NPSR: Supply of color outdoor network HD IR Bullet Camera.
#) 4 Megapixel,H-264T/MJPEGProgrssvie scan CMOS, 120db (WD) and IR upto 30mts. image sensor #) 3.6mm lens (2.8mm, 6mm, 8mm optional) Make CP plus ,Samsung, Sony. (Inclusive of GST)
16
-
-
Code No. NPSR: Supply of color Indoor HD IP IR Dome Camera
#) 4 Megapixel,H-264T/MJPEGProgrssvie scan CMOS, 120db (WD) and IR upto 30mts. image sensor #) 3.6mm lens (2.8mm, 6mm, 8mm optional) Make CP plus ,Samsung, Sony. (Inclusive of GST)
2
-
-
Code No. NPSR: Supply of 4TB Hard disk (Surveillance HDD) for video storage in NVR Make:Seagate / western digital. (Inclusive of GST)
2
-
-
Code No. NPSR: Supply and installation of sine wave Invertor of 1KVA capacity with back up for 6hours along with 12V , 150AH batteries - 2nos.Make : Luminous / Exide. (Inclusive of GST)
1
-
-
Code No. NPSR: Supply of wall mounted network Rack -9U door glass, completely covered and have security locks, proper ventilated with one fan one cable manager, power distribution unit of 6nos., (5A) sockets with surge protection, mounting accessories and, 5A top Ventilation switch. (Inclusive of GST)
1
-
-
Code No. NPSR: Installation of wall mounted network Rack-9U door of glass, completely covered and have security locks, proper ventilated with one fan one cable manager, power distribution unit of 6nos., (5A) sockets with surge protection, mounting accessories and 5A top ventilation switch. (Inclusive of GST)
1
-
-
Code No. NPSR: Supply of DGS 1210 series 24 Port Network switch. (Inclusive of GST)
1
-
-
Code No. NPSR: Supply of 32inch LED Monitor .Make: Samsung / LG /Sony. (Inclusive of GST)
1
-
-
Code No. NPSR: Supply and laying of cat 6 cables laying with PVC pipe & Material. (Inclusive of GST)
1500
-
-
Code No. NPSR: Supply and drawing of 1.5sqmm 3 core flexible power cable. Make:- Finolex/ Polycab/Havells.(Inclusive of GST)
300
-
-
Code No. NPSR: Installation charges for cameras and recording system including testing and commissioning. (Inclusive of GST)
1
-
-
Civil PSR Code No.31.280.1A Supplying of 3 phase, 415 volts, 50 cycles, 0.8 power factor for electric starting diesel generator comprising the following units:-(Kirloskar/ Leyland/Ruston /Greaves Cotton/Cummins make) air cooled and shall be of multi stroke, multi cylinders, cold starting, developing not less than 43 BHP under normal temperature and pressure. The engine shall conform to I.S. 10002 with latest amendments. It shall be capable of taking 10% over load for one hour in every 12 hours of continous operation including 6 Nos. of anti vibration pads.The engine shall be complete with the following accessories:Electrical starting provision, engine cooling fan, fuel and lubricating oil filters, oil bath, air filter, lub oil pressure gauge 90 litres capacity fuel tank mounted with engine, hour meter with exhaust manifold, flexible pipe, 12 /24 volts electric starting equipment complete
1
-
-
Civil PSR Code No.31.281.1A Providing and fixing of suitable M.S.exhaust pipe including 2 Nos. of M.S.bends (long), 7 Nos. of M.S. flanges, M.S.pipe Class B - 5 Rm as flexible exhaust pipe. The rate is inclusive of transportation charges for shifting of welding machine and gas cutting set to site, consumption of welding rod 10 SWG and cutting gas, providing fasterners of 10mm bolts / nuts / washers and flange gaskets including labour charges etc. as per IE standard.-65 mm dia exhaust pipe (upto 40 KVA)
1
-
-
Civil PSR Code No.31.284.1A Providing and fixing of 4 pole change over switch of STANDARD/HAVELLS/KUNDAN/ GEM make including M.S. frame as per I.E. standard.-100 Amps (upto 50 KVA) standard.-65 mm dia exhaust pipe (upto 40 KVA)
1
-
-
Civil PSR Code No.31.285.1A Charges for transporting, erection, testing and commissioning of generator set excluding foundation,but including mechanical and other unskilled wages for installation of equipment, wiring from generator set to panel board and change over switches, handling charges, purchase of spares if any required for the installation and commissioning, the cost of fuel and other materials for a trial run of 6 hours. This rate also includes for testing and commissioning of generator set as specified, obtaining approval of Central Electricity Authority (CEA),payment for CEA inspection/Licence fees or any other charges and fulfilling other requirements and conditions laid down by CEA-From 30 KVA to 50 KVA
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%