Public Works Department Tender
View complete overview of Puducherry PWD Tender
Public Works Department - PWD Tender
Eprocure
Opening Date1 Sep 2020
Closing Date23 Nov 2020
Tender Amount₹ 17,77,748 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 35,555Document Cost
₹ 525Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2020_PWDC2_6603_1Bid Award Id
ViewTender No
14/PHD/2020-21Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://pudutenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply and erectionof stay set complete for H.T. poles.
4
-
-
Supply and fixing of H.T. tapping channel cross arm without clamp ( 100 x50 x 6)
5
-
-
Supply and fixing of 22 KV Disc insulator with metal parts.
15
-
-
Suppy and laying of concreting of H.T. Pole
6
-
-
Supply and fixing of 22KV 'V' cross arm without clamp.
2
-
-
Supply and fixing of H.T. guarding cross Arm without clamp (75 x 40 x 6mm)
2
-
-
Supply and fixing of L clamp
6
-
-
Supply and fixing of All sizes of M.S. bolts and nuts
40
-
-
Supply and fixing of stay clamp
6
-
-
Earthing of H.T pole (including materials and Labour charges)
7
-
-
Supply and straining of ACSR conductor of 6/1/2.59mm
950
-
-
Supply and fixing of 22KV Pin insulator
15
-
-
Supply and fixing of 22 KV GI pins
15
-
-
Supply and laying of Copper flat 25 x 3 mm
25
-
-
Supply and laying of 8 SWG copper wire
5
-
-
Supply and erection of 4 way 600 Amps SS Pillar Box
1
-
-
Supply of 3 1/2x 300 sqmm armoured PVC aluminium U.G cable - 1.1 KV grade. Make:Finolex/Poycab
70
-
-
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1KV grade of exceeding 120 sq.mm. but not exceeding 400 sq.mm. direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required in Mud Road
50
-
-
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1KV grade of size exceeding 25 sq.mm but not exceeding 400 sq.mm in the existing masonary open duct as required:-
20
-
-
Supply of cable gland for 31/2x 300 sqmm LT UG cable
8
-
-
Supply, erection and commissioning of HT metering panel as per the specificaitona nd requirements of Puducherry Electricity Department
1
-
-
Construction of platform of size 1.00x0.50x0.50m above the ground level for erecting the metering panel board for transformer. The rate includes the cost of earthwork excavation of size 1.00mx0.50mx0.60m, river sand filling to the platform of size 1.00mx0.50x0.15m platform of size 1.00mx0.50mx0.45 with necessary centring and shuttering, plastering the exposed surface and colour washing the plastered area as directed by the Engineer-in-Charges
1
-
-
Construction of Plinth for eretion of pillar Box including chnnels. Brick works and Plain cement concreting as per the requirement. The cost should be inclusive of minor modification suitable for site condition as approved by the engineer-in-Charge.
1
-
-
Earthing with G.I. medium pipe 3.0 mt long and 40mm dia including accessories 250x50x6mm G.I. clamp with 12mm bolt, nut and washer for connecting earth wire, RCC ring enclosure and cover plate complete as required:-
3
-
-
Providing safety equipments - Rubber mats as per IS 15652 - 2006 - ISI marked specifications (2mm thicknes) size 1m x 2 m (colour - Black) (For all the panels)
6
-
-
Providing safety equipments - 11 KV Hand Gloves (ISI) tested)
1
-
-
Supply and fixing of Danger Board 22000/440 volts
5
-
-
First Aid Box treatment chart with 8 mm thickness MDF photo lamination - multi colour size 18" x 2 " both local languages in English & Tamil ( to be fixed in the power room)
2
-
-
First Aid Box - Metal Medium - Ms wall mountable power coated box with 5 compartment fitted with Acrylic door and carrying handle filled with medicines - size: 11" x 12" x 6" (to be fixed in power room)
1
-
-
Stand to hold 4 nos. of fire bucket made of MS angle 32 mm x 32 mm x 3 mm size height 34" x length 44" painted in red colour (with 4 nos. of round bottom fire bucket made of 22 gauge galvanized sheet of 9 lits capacity painted with white colour inside and fire red colour outside mentioning FIRE in black letters and one handle at the top and anothe in the side) with necessary bricking work for fixing of stand
2
-
-
Supply and fixing of 4.5 KG Co2 fire extinguisher
3
-
-
Central Electricity authority Inspection and approval for the HT Installation, preparation of relevant documents, obtaining approval for energisation and Liaisoning works.
1
-
-
Supply of Stone aggregate (Single size): 40 mm nominal size
5
-
-
Supply, erection and testing and commissioning of outdoor type 22/0.433KV, 315KVA Energy efficient Level-II distribution transformers as per the Puducherry Electricity Department specifications with off load tap switch having position with voltage connection in steps of 2.5% with all required accessories. As per the Electricity Department specification Make: RPG Raychem(P) Ltd/Indotech/Kirloskar/Wilson/Sakthi Transformers. (Inclusive of all Taxes)
1
-
-
Supply, testing and erection of floor mounted 100 KVAR automatic Power factor control panel consisting of the following in corner feeder fitted with 160 A TPN SFU with HRC fuses, Voltmeter with selector switches, Microprocessor base controller, auto manual selector switch, Emergency push button to switch off panel, capacitor contactors of adequate rating, Manual switching push button with indication lamps, for 3 phase supply. The equipments shall be fully factory Assembled and tested - Capacitor -Make:Epcos/Siemens
1
-
-