Municipal Administration And Water Supply Department Tender
View complete overview of Puducherry Municipal Administration And Water Supply Department Tender
Municipal Administration And Water Supply Department Tender
Civil And Construction
Building Construction
Eprocure
Opening Date23 Feb 2023
Closing Date28 Feb 2023
Tender Amount₹ 25,00,000
Costs
EMD
₹ 25,000Document Cost
₹ 1Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_MAWS_290448_1Bid Award Id
ViewTender No
630/2022/E1Tender Authority
Municipal Administration And Water Supply Department ViewPurchaser Address
-Website
http://tntenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Plain Cement Concrete 1:4:8 (one cement four fine aggregates and eight coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification
2.46
-
-
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid)
68.58
-
-
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid)
-
-
-
For plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc
137.71
-
-
For plane surfaces such as rectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc.
43.25
-
-
M-20 CONCRETE - Providing and laying in position, standarised design mix M-20 Grade using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 350Kg/m3 and maximum water cement ratio of 0.55, including admixture(plasticiser/super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.70 cu.m.)940.50Kg of 20mm machine crushed stone jelly and with about (2.80 cu.m.)462.00Kg of 10-12mm machine crushed jelly and with about (4.25 cu.m.)701.25Kg of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor/roof slabs wherever neccessary without clambing extra, etc. complete complying with standard specification and as directed by the departmental officers. the coarse and fine aggregates to be used should comply with the requierments of IS 383-2016. (No separate payment will be made by the department for the exces usage of materials as per design mix.) (SI No 81)
-
-
-
Foundation
5.93
-
-
Ground Floor
28.26
-
-
Suppling and fabricating and placing in position MS (or) R.T.S. bar for reinforcement to all RCC works as per the design given including cost of steel and binding wire also in all floors.
3.6
-
-
Brick work in CM 1:5 (one cement & five sand) using II class ground moulded bricks of size 9"X43/8"X 2 3/4" including finishing, curing, etc., complete complying with standard specification.
-
-
-
Ground Floor
38.39
-
-
Brick Partition Walls using III class ground moulded chamber bricks of size 8 3/4"X43/8"X 23/4" in C.M 1:3 using hoop iron reinforcement,if found necessary standard specification including finishing, curing,etc., complete complying with standard specification.
-
-
-
Ground Floor
2.54
-
-
Plastering with cement mortar 1:3,10 mm ,thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications (S.I.306)
129.77
-
-
Plastering with cement mortar (1:5) 12mm ,thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications (S.I.306)
345.25
-
-
Dadooing Supplying and laying in flooring with fully polished Sinthetic Grey colour Granite stone of 10mm thick (average) of 2' X 1' in size laid in cement mortar 1:2 - 20 mm thick & pointed with same colour of cement etc., complete as per standard specification
6.31
-
-
Painting two coats with ready mixed Plastic Emulsion Paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. - 10 sq.m
475.02
-
-
Laying the Flooring with Anti skid coloured ceramic tiles of sizes 305mm X305mm X 6mm size of approved make and quality and colour l Set in cement mortar 1:3 (one cement ,three sand) over 20 mm base layer plastering and pointing with white cement neatly as directed.
11.11
-
-
Dadooing walls with Glazed tiles of sizes 305mm X200mm X 6mm size of approved make and quality and colour l Set in cement mortar 1:2 (one cement ,two sand) over 10 mm base layer plastering and pointing with white cement neatly as directed.
17.19
-
-
Paving the floor with Vitrified Marbonite tiles of approved quality and colour of size 600x600x8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3(one cement three sand) 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer. The colour & quality of tiles should be got approved by Municipal Engineer before use on work
58.14
-
-
Supplying & fixing door shutters for Mediun Density Fiber Board of exterior grade 35 mm thick,single leaf conforming to IS:12406/1989 with 35x12 mm T.W.Lipping on all edges with necessary adhesives and CP screws complying with standard specifications. The rate is inclusive of threee coats of best quality varnish but excluding cost of furniture fittings.such as 300 mm tower bolt 2nos,200mm towerbolt I no. 300mm Aldrop 1 No. Alu handle ornamental type 2 Nos,and 1 No. Door stopper etc complete.
10.92
-
-
Supply and fixing of PVC Solid Doors using 19gauge 19mm MS Sq,tubes for styles and frames, 15mm MS Sq.tubes for to, Lock and bottom rails. The Steel Tubes shall be covered with 5mm thick Solid PVC sheets. Shutter using 5mm thick solid PVC sheets for panelling shall rigidly fixed in position including furniture and fittings. The over all size of styles shall be 50mm X 30mm. The over all size of top rail, Lock rail and bottom rail shall be 75mm X 30mm. The over all size of frames shall be 50mm X 45mm with suitable tabate for housing the shutter etc, complete as per standard specification.
6.3
-
-
UPVC Ventilator
Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work
1.44
-
-
UPVC Window
Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned.
Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work
8
-
-
Designing the Semi Unitised Structural Glazing System with open groove joint as per design intent, preparation of shop drawings for approval, supply, fabricate, erect as per
approved shop drawings at all floor levels and all floor heights including conducting field test as per the test criteria set out in the particular specification (Metholodgy should be got approved by the Dept.
Officials.) Design the framing system (i.e. male & Female frame) to support vision panels, spandrel panels either with glass or aluminium composite panel, openable, window panels on a continuous framing supported between floors. Also design the split framing unutilized glazing system in case of strip or punched windows with vision panel proposed with either insulated / Monolithic glass, groove width in the system both in horizontal and vertical shall not be more than 20mm. Glazing of panel shall be done only at factory at the controlled atmosphere
3
-
-
Finishing the top of roof with one course of machine pressed tiles of size 200 mm x 200 mm x 20 mm of approved quality in Cement Mortar 1:3 (One Cement add three sand) 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete
70.28
-
-
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete
5.4
-
-
Weathering Course with Concrete Broken Brick (S.I.No.278) & ( P & D) Data 54.Jelly 20mm gauge in pure slaked lime (no sand to be added) over roof slab,the proportion of brick jelly to lime being '32 to 12.5 well beated with wooden beaters for giving required slope and thickness as directed by the departmental officers etc., complete.-10 cum
7.03
-
-
Supply and fixng of TNEB meter board suitable for 3 phase 200A service connection made up of suitable angle iron frame work of size 3 feet x 2 feet using angle iron of size 1-1/2" x 1-1/2" x 1/4" rigidly fixed on wall covered with
hylem sheet of size 3 feet x 2 feet of 12mm thickness with necessary bolts and nuts supports and supply and fixing
of 3 Nos. 200A fuse units (500V), 1 No. neutral link, copper earth flat of size 1" x 1/4" with inter connection of EB
meter to fuse units by 19/16 PVC insulated copper wire with earth connection complete
1
-
-
Supply and fixing 16amps DP switch with metal clad(side handle) of 500 V with F & N on suitable teak wood Board of size 30cmx20cmx6 cm including necessary internal conection,earth connection etc.,complete )
2
-
-
Supply an fixing o 6way SPDB of 16A /way with 16ADP switch with metal clad of 500V with fuse and neutral (sidehandle) on suitable angle iron frame work with trunking box MS cableen try box with PWD earthing
2
-
-
Supply and run off 2 of 4 sqmm PVC insulated single core unsheathed copper conductor cable of 1100 V grade with ISI mark confirming to IS:694/1990 with continious earth connection by means of 1.50 sqmm PVC insulated single core unsheathed copper conductor cable confirming to IS:694/1990 in suitable PVC rigid pipe 1.8mm thick concealed in wall for mains including the cost of PVC pipes and specials, cables, cement, brass screws, T.W plugs, saddles and labour etc., complete in all respects as directed by the departemental officers.
10
-
-
Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated unsheathed SC copper conductor of 1100V grade in
suitable PVC rigid pipe concealed in wall and ceiling with PVC accessoires with TW switch box and 5A FT switch
in flush with wall with 3mm thick hylum sheet cover for making good of the concealed portion with suitable
colour for PVC concealed fan point (for electronic regulator)
6
-
-
4 ways 3 phase DB
No. of ways incomer MCB / Isolator - 4 No. of ways incomer ELCB / RCD - 4 No. of outgoings ways - 12
3
-
-
Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with doubledoor (metal) 1 No. 32A DP MCB as incoming and 6 Nos. 6A to 32A SPMCB outgoing in flush with wall andmaking good of the concealed portion with earth connection only. The MCB DB and MCB's should be with ISImark (like standard make)
3
-
-
Supply and fixing of 32A TPNMC switch with suitable angle iron frame work with MS cable entry boxes with earth connection only
3
-
-
AIR CONDITIONER (AC) SUPPLY & INSTALLATION OF AIR-CONDITIONER WITH COPPER COIL. 1.5 TR Split Type AC Unit
2
-
-
Supply and installation of 5 KVA capacity Automatic Voltage Stabilizer with time delay relay
2
-
-
Supply and laying of 5/8" and 3/8" copper pipe (Extra beyond 3 metres supplied with AC unit)
2
-
-
Supply and fixing of MS stand for fixing outdoor unit
2
-
-
Wiring with 2x1.5sqmm PVC insulated single core unsheathed copper conductor cable of 1100V grade with ISI mark confirming to IS: 694/1990 in suitable PVC rigid pipe of 1.8mm thick with ISI mark concealed in wall and ceiling with PVC accessories in flush with wall including the cost of cable, pvc pipe and specials, ceiling rose, flush type 5ams SP mark switch, PVC junction box, 16gauge MS switch box 100mm x 100mm x 75mm covered by laminated hylem sheet 3mm thick, cement, labour and making good of concealed portion with suitable colour for concealed PVC LIGHT point.
2
-
-
Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated single core unsheathed copper conductor of 1100V grade in
suitable PVC rigid pipe concealed in wall and ceiling with PVC accessoires in flush with wall with 3mm thick hylum
sheet cover with TW switch box and 5A FT switch and making good of the concealed portion with suitable colour for PVC concealed light (6 points per coil) (for rooms like bath, toilet & pumproom, etc.)
2
-
-
Wiring with 3 x 1.5 sq.mm. (22 / 0.3) PVC insulated single core unsheathed copper conductor of 1100V grade in
suitable PVC rigid pipe on wall and ceiling with PVC accessories and with TW switch box and 5A FT switch (two way)
with painting of suitable colour with continuous earth wire connection of 14 SWG TC wire for open PVC straircase
light point
2
-
-
Supply and run off 2 of 2.50sqmm PVC insulated single core unsheathed copper conductor cable of 1100 V grade with ISI mark confirming to IS:694/1990 with continious earth connection by means of 1.50 sqmm PVC insulated single core unsheathed copper conductor cable confirming to IS:694/1990 in suitable PVC rigid pipe 1.8mm thick concealed in wall for mains including the cost of PVC pipes and specials, cables, cement, brass screws, T.W plugs, saddles and labour etc., complete in all respects as directed by the departemental officers
50
-
-
Supply and fixing of 5A / 15 A 3 Pin combined flush type wall socket with 15A flush type switch concealed in suitable MS Box in flush with wall and covered with 3 mm thick hylem sheet
6
-
-
Supply and run off 2 of 4 sqmm PVC insulated single core unsheathed copper conductor cable of 1100 V grade with ISI mark confirming to IS:694/1990 with continious earth connection by means of 1.50 sqmm PVC insulated single core unsheathed copper conductor cable confirming to IS:694/1990 in suitable PVC rigid pipe 1.8mm thick concealed in wall for mains including the cost of PVC pipes and specials, cables, cement, brass screws, T.W plugs, saddles and labour etc., complete in all respects as directed by the departemental officers
15
-
-
Earthing as per the ISI specification with an earth electrode of 2.10 metre Class 'B' GI pipe of dia not less than40mm with copper earth plate of size 125mm x 50mm x 6mm with necessary funneling arrangements withnecessary masonry work and with 38mm RCC cover slab for the brick masonry
3
-
-
Supply and run of 1 of No.8 SWG GI wire for earth connection
30
-
-
Supply and fixing of 18W LED 3000K Square type resessed fiiitng (Philips/Havells) complete with T.W round blocks on wall or ceiling with flu tube with PVC unsheather copper leads from terminals to the filling
9
-
-
Supply and fixing of single box type 4'36W fluorescent fitting complete with electronic ballast with TW roundblocks on wall or ceiling with flu tube with PVC unsheathed Copper leads from terminals to the fitting
6
-
-
Supply and fixing of WT bulk head fitting with guard (Philips / Bajaj / Crompton / K-Lite) suitable for 11W CFL
4
-
-
Supply and fixing of 1200mm (48")sweep AC ceiling fan complete with stepped electronic 300W regulator with the
existing down rod on the existing clamps.
5
-
-
Supply and fixing of 5A / 15A 3 pin combined flush type wall socket with 15A flush type switch on suitable TW Box
6
-
-
Add GST 18%