Indira Gandhi Medical College And Research Institute Tender
View complete overview of Puducherry Indira Gandhi Medical College And Research Institute Tender
Indira Gandhi Medical College And Research Institute Tender
Security and Emergency Services
Eprocure
Opening Date15 Jun 2023
Closing Date13 Jul 2023
Tender Amount₹ 7,01,66,404
Costs
EMD
₹ 14,03,330Document Cost
₹ 1,575Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_MH_12900_1Bid Award Id
ViewTender No
13/ IGMC RI/EC /EEE/ 23-24Tender Authority
Indira Gandhi Medical College And Research Institute ViewPurchaser Address
-Website
http://pudutenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Monitor modules
15
-
-
Control modules for fan, AHU kitchen hood etc. with 230V 2A relay where ever required.
15
-
-
Supply, installation, testing and commissioning of signal initiating devices complete with galvanised steel, back box, detector with base etc.complete as specified and as required.
-
-
-
Addressable photoelectric smoke detectors below false ceiling.
300
-
-
Addressable photoelectric smoke detectors above false ceiling with necessary frame work for mounting base.
300
-
-
Addressable multisensor detectors
20
-
-
Addressable break glass unit with fire fighters telephone jack in galvanised back box.
20
-
-
Response Indicator
300
-
-
Point wiring for below false ceiling detectors break glass modules, control and monitor modules consisting of 2 nos 1 pair 1.0 sqmm armoured FRLS copper multistrand, twisted pairs, PVC wires generally as shown on drawings. (one pair spare)
36
-
-
Point wiring for above false ceiling detectors including response indicator consisting of 2 nos 1 pair 1.0 sqmm armoured FRLS copper multistrand, twisted pairs, PVC wires generally as shown on drawings. (one pair spare)
36
-
-
Supply, installation, teseting & commissioning of public address speakers for the integrated voice evacuation system with
6 W public area ceiling speakers 85 dBA @ 3m at lowest setting complete with backbox.
25
-
-
Point wiring for PA system with 2 nos 1 pair 1.0 sqmm armoured FRLS copper multistrand, twisted pairs, PVC wires generally as shown on drawings. (one pair spare)
67
-
-
Looping of Main panel and secondary panels with CAT 6 UTP cable in 25mm dia PVC conduit.
160
-
-
Supply of Smoke Detectors, Multisensor detectors, Heat Detectors, Control Modules & Monitor Modules individually packed in polythene bags.
-
-
-
Monitor Modules
10
-
-
Control Modules for fan, AHU & kitchen hood control
10
-
-
Addressable photoelectric smoke detectors
10
-
-
Addressable Multisensor detectors
10
-
-
Addressable break glass unit with fire fighters, telephone jack in galvanised back box
10
-
-
Addressable heat detector
10
-
-
6W public area ceiling speakers 85 dBA @ 3m at lowest setting complete with back box.
10
-
-
Fire Fighting System
Fire Hydrant And Sprinkler Pumping Systems
Supply, installation and testing of fire pumps, electrically driven generally as specified and shown in data sheet complete with: i) all accessories as mentioned in the data sheet.
ii) vibration mounts & suction and discharge flexibles. iii) test connection excluding starter panel & foundation.
-
-
-
Main & standby pumps of centrifugal multistage pump, capacity 2850 lpm, head 100m, motor 90KW, casing iron, impeller bronze, shaft EN8.
4
-
-
Main & standby pumps of centrifugal multistage pump, capacity 450 lpm, head 95m, motor 11KW, casing iron, impeller bronze, shaft EN8.
1
-
-
Providing, Fixing, Testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following: complete in all respect as required.
-
-
-
Horizontal, centrifugal, back pullout pump to ensure a minimum pressure of 3.5 kg / sq.cm. at highest and farthest outlet at specified flow of 4550 lpm at 70m. head conforming to IS standards.
Diesel engine of 1800rpm, 120HP water cooled type with radiator conforming to relevant BS & IS standard complete with auto starting mechanism, 12 volts/24 volts electric starting equipment, Diesel tank, exhaust pipe extended up to 1 m. outside pump house duly insulated with 50 mm. thick glass wool with 1.0 mm. thick aluminium sheet cladding, residential silencer, instruments and protection as per specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.
1 no. 2 hours capacity day diesel storage tank fabricated from 3 mm thick M.S plates. Tank shall be provided with inlet, outlet, overflow, air vent, drain connections, filling connection and magnetic level indicator. Tank shall be mounted on a suitable steel structure (painted with 2 coats of red oxide paint). tank shall be provided with epoxy coat from inside & two or more coats of synthetic enamel paint outside over two coats of red oxide primer
24 volts 180 AH lead acid battery (12 volts- 2 Nos) with boost/trickle charger for starting the engine automatically complete as required.
Common Base plate for Pump and engine and coupling, coupling guard and other accessories as required for complete installation of pump set.
1
-
-
Supplying, installing, testing and commissioning of Air Vessel 3m³ capacity having 1320mm O.D x 2m cylindrical height, made out of 12mm thick Dishend and 10mm thick Shell of I.S:2062 Gr-A/B having dish end welded with shell manufacturing as per Design code I.S:2825, Class II suitable for working pressure 7Kg/cm², Hydrotested at 21Kg/cm², Joint efficiency 0.85, Radiography longitudinal seam 100%, Circumferential seam 10% spot with all necessary valves & fittings.
1
-
-
Supply and installation of pressure gauge panels for hydrant system and sprinkler system generally as shown and comprising: i) Pressure gauges. ii) Pressure switches. iii) Water piping from various systems upto the gauge panel. iv) Painted Sheet metal enclosure with glass paneling.
3
-
-
Hydrant System
Supply and installation of internal and external hydrants as shown on drawings and meeting the intents of specifications.
-
-
-
Internal hydrants/landing valves generally as specified & shown on drawings complete with:
i) Twin headed landing valve.
ii) 20mm dia 30m long first aid rubber hose on M.S reel with ball type shut off valve tapped from the riser with GI pipe
iii) 63mm dia Reinforced Rubber lined canvas hoses 2 # 15m long.
iv) branch pipe & nozzle.
v) painted 3mm M.S hose cabinet with glass front of approved design
5
-
-
External hydrant single head stand-post type generally as specified & shown on drgs.
50
-
-
External hose cabinets as specified for wall mounting or free standing complete with:
i) Mild steel or fibre glass cabinet with glass vision panels & support structure
ii) 63mm dia controlled percolation canvas hoses 2 x 15m long hoses with couplings and Nozzle or branch pipe
50
-
-
Fire brigade inlet connection to Fire Tank,fire system with two twin headed 63mm valves or 4 way connection ,150 mm M.S pipe stand and header as specified & shown on drawings.
5
-
-
Supply and Installation of Sluice Value ( Including of all accessories)
-
-
-
250mm dia
3
-
-
200mm dia
3
-
-
150mm dia
3
-
-
Supply and Installation of Y strainer 250mm (Including all accessories)
3
-
-
Supply and Installation of Sluice Value ( Including of all accessories)
-
-
-
250mm dia
2
-
-
200mm dia
5
-
-
100mm dia
2
-
-
Sprinkler System
Supply and installation of isolation valve as specified and shown on drawings and complete with:
i) Mains stop butterfly valve
ii) Isolation valve with retard chamber
iii) Pressure gauges
iv) Test connection with ball valve
v) Water motor, gong, ball valve, strainer etc.
vi) All inter connected galvanised steel piping connection etc complete
150mm size
10
-
-
Supply and installation of chromium plated or white polyester coated fast response sprinklers generally as specified complete with escutcheon plates as shown on drgs.
-
-
-
Pendant type 15/10mm 57°C
3500
-
-
Pendant type 15/10mm 79°C
100
-
-
Upright type 15/10mm 57°C
800
-
-
Sidewall type 15/15 57°C Extended coverage
20
-
-
Supply and installation of 1m long (UL Listed) stainless steel flexible pipe connection to sprinkler head.
1000
-
-
Supply Sprinklers individually packed in polythene bags.
-
-
-
Pendant exposed type 15/10mm/57°C
30
-
-
Upright type 15/10mm/57°C
30
-
-
Supply of 1m long (UL Listed) stainless flexible pipe
100
-
-
Piping For Fire Fighting
External Piping
Supply and Laying external piping (UNDERGROUND) generally as specified using M.S. pipe conforming to IS 3589 (for pipe sizes above 150 mm) & G.I. Pipe confirming to IS 1239 (for welded pipes upto 150mm) heavy' class complete with:(Including Dismantling)
i) All pipes and fittings together with flanges, neoprene gaskets, bolts & nuts
ii) "Pypcoat" wrapping as specified.
-
-
-
300 n.b
20
-
-
250 n.b
20
-
-
200 n.b
4000
-
-
150 n.b
500
-
-
80 n.b
200
-
-
Excavation upto hard murram as per general profiles and back filling
2500
-
-
Making 1:2:4 cement concrete supports and thrust blocks generally as shown on drawings.
75
-
-
Supply & installation of butterfly valves with holding flanges generally complete as specified.
-
-
-
250 n.b
5
-
-
200 n.b
20
-
-
150 n.b
40
-
-
100 n.b
40
-
-
80 n.b
20
-
-
65 n.b
40
-
-
Providing brick masonary valve chamber generally as specified complete with cast iron surface box. (Heavy duty)
a) 900x900 (1200mm depth)
20
-
-
Internal Piping
Supply and Laying heavy class M.S pipe confirming to IS 3589 for size above 150mm and galvanised mild steel pipes conforming to IS1239 upto size 150mm laid to slopes with all fittings (excluding flanges) as specified.
-
-
-
150 n.b with welded Joints
1500
-
-
100 n.b with welded Joints
1000
-
-
80 n.b with welded Joints
500
-
-
65 n.b with welded Joints
1250
-
-
50 n.b with heavy duty welded / screwed fittings
1500
-
-
40 n.b with heavy duty welded / screwed fittings
1200
-
-
32 n.b with heavy duty welded / screwed fittings
50
-
-
25 n.b with heavy duty welded / screwed fittings
2100
-
-
Supply & Installation of ball valves with supports etc.
25 n.b gun metal (screwed)
10
-
-
Supply, installation, testing, & commissioning of flow switch assembly complete with:
i) Flow switch
ii) Isolating ball / Butterfly valve with 2A tamper switch.
iii) flanges or union connections
100 mm
40
-
-
Portable Fire Exitinguishers
Supply, installation of Portable Fire Extinguishers as described below:
-
-
-
5 Kg DCP extinguisher
23
-
-
5.0Kg CO2 extinguishers
13
-
-
Buckets with dry clean sand-4 nos with stand
10
-
-
Electricals For Pump room
Supply, installation and testing of Fire Pump Panel generally as specified and as per drawing
i) Panel with digital voltmeter and ammeters (with selector switch), starters, bus bars, indicating lamps, internal wiring & earthling.(As per the direction of the Engineer - in- charge)
1
-
-
Providing remote push button station ON-OFF lockable in Powder coated enclosure for the main and standby pump at the fire control room (Hospital) with indicating lamps
1
-
-
Supply, laying, testing and commissioning of 1100 V grade PVC insulated and FRLS sheathed and armoured cables indoor or outdoor with Aluminimum conductor as specified complete with. Cable clamps on walls columns, beams, built-up trenches, cable markers etc. complete earthing the glands armouring etc.
-
-
-
3.5C 300 sqmm AYFY
350
-
-
3.5C 185 sqmm AYFY
200
-
-
4C 16 sqmm YRY
100
-
-
4C 1.5 sqmm YRY (Control Cables for Remote push button station for Pump start stop, pressure gauge station etc.
800
-
-
Making cable end terminations including brass compression glands and double crimping type copper lugs for Al/Cu cables
-
-
-
3.5 C 300 AYFY
24
-
-
3.5 C 185 AYFY
24
-
-
4 C 16 YRY
24
-
-
4 C 1.5 YRY
24
-
-
Supply and installation of GI cable trays complete with painted supports.
Perforated cable tray 600 x 50x2mm thick
75
-
-
Supply and laying of main earthing as shown on drawing. 25 x 3 copper
30
-
-
Earthing with G.I. earth pipe 3.0 meter long, 40 mm dia including accessories, and providing masonary enclosure with cover plate etc. with charcoal / coke and salt as required
10
-
-
Providing and fixing 25 mm x 5 mm G.I.strip in 40 mm G.I.pipe from earth electrode including connection with G.I.nut , bolt,spring , washer excavation and re-filling etc.as required
100
-
-
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required
200
-
-
Dismantiling if any
Dismantling the existing pipes and equipments if any without any damages and keeping safely to a place as directed by the engineer in charge.
Before Quoting the Vendors need to visit the site.
1
-
-
Repainting existing pipe lines Painting for Existing Fire pipes as per the standard based on the condition at Site
'Before Quoting the Vendors need to visit the site.
1
-
-
Liasoning charges for obtaining the fire safety approval from the concerned department
1
-
-