India Tourism Development Corporation Limited Tender
View complete overview of Puducherry ITDC Tender
India Tourism Development Corporation Limited - ITDC Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date25 Mar 2022
Closing Date6 Apr 2022
Tender AmountRefer Documents
Costs
EMD
₹ 4,50,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_ITDC_111178_1Bid Award Id
ViewTender No
PAHCL/SECBP/SITC/2022Tender Authority
India Tourism Development Corporation Limited ViewPurchaser Address
-Website
http://http://itdc.co.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
SITC FOR FACADE LIGHTING OF CHIEF SECRETARIAT BUILDING AND BHARATHY PARK PUDUCHERRY
SITC FOR FACADE LIGHTING OF CHIEF SECRETARIAT BUILDING AND BHARATHY PARK PUDUCHERRY
BOQ Items
Design Supply Installation Testing and Commissioning of 1000mm Length RGB with neutral white LED linear grazing luminaire high power LED with housing material of extruded aluminium with die-cast aluminum end caps, dark grey anodized finish, system wattage should be less than or equal to 80W at full load and system lumen output of not less than 3100 lumens. Fixture shall be avilable with high power LED and architectural optics with choice of beam angles of Elliptical 15°- 20°x35°-40°. The luminaire shall be able to deliver 190lx at 24 ft from luminaire with a beam width of 15 ft in horizontal and 7ft in vertical plane. The luminarie peak intensity shall be minimum 10000Cd The luminaries shall be with Anti-aging and anti-UV high optical efficiency PMMA lens and clear tempered glass for better illumination. The white LED should have SDCM 4 for better color. Fixture dimension shall be not larger than 1000 x 105 x 80 mm with out bracket and weight not more than 5.0kgs. Luminarie should have IP67 rated male/female connectors for DMX through wiring. Fixture shall operate in a temperature range of -40°C to 50°C and startup temperature range of -35°C to 50°C. Fixture shall have auto-ranging input voltage for 120 – 277 VAC. Lifetime should be at least 50,000 burning hours at L70 at 35 degree centigrade with total IP66 protection. Fixture shall equipped with mechanical impact of minimum IK06.
28
-
-
Design Supply Installation Testing and Commissioning of exterior rated circular shaped RGB with neutral white LED flood light luminaire. The luminarie housing material shall be extruded aluminium with die-cast aluminum end caps, dark grey finish, system wattage should be less than or equal to 36W at full load and system lumen output of not less than 1500 lumens. Fixture shall be avilable with architectural optics with choice of beam angles of 10°-15°x 10°- 15° Mid beam. The luminaries shall be with Anti-aging and anti-UV high optical efficiency PMMA lens and clear tempered glass for better illumination. The white LED should have SDCM 4 for better color. Fixture dimension shall be not larger than Ø205 mm x 157 mm (without bracket) and weight not more than 5.0kgs. Luminarie should have IP67 rated male/female connectors for DMX through wiring. Fixture shall operate in a temperature range of -40°C to 50°C. Fixture shall have auto-ranging input voltage for 120 – 277 VAC. Lifetime should be at least 50,000 burning hours at L70 at 35 degree centigrade with total IP66 protection. Fixture shall equipped with mechanical impact of minimum IK08.
9
-
-
Design Supply Installation Testing and Commissioning of circular warm white LED flood light luminaire high power LED with housing material of extruded aluminium with die-cast aluminum end caps, dark grey anodized finish, system wattage should be less than or equal to 28W at full load and system lumen output of not less than 1500 lumens. Fixture shall be available with high power LED and architectural optics with choice of beam angles of Elliptical 5°- 10°x5°-10°. The luminaire shall be able to deliver 500lx at 24 ft from luminaire with a beam width of 4 ft in both horizontal and vertical plane. The luminaire peak intensity shall be minimum 26000Cd The luminaires shall be with Anti-aging and anti-UV high optical efficiency PMMA lens and clear tempered glass for better illumination. The white LED should have SDCM 4 for better color. Fixture dimension shall be not larger than 190mm dia and 150mm height without bracket and weight not more than 3.0kgs. Fixture shall operate in a temperature range of -40°C to 50°C and startup temperature range of -35°C to 50°C. Fixture shall have auto-ranging input voltage for 120 – 277 VAC. Lifetime should be at least 50,000 burning hours at L70 at 35 degree centigrade with total IP66 protection. Fixture shall equipped with mechanical impact of minimum IK06.
1
-
-
Supply Installation Testing and Commissioning of compact DMX signal amplifier that takes the incoming DMX512/RDM signal and amplify the signal into long distance transmission. The housing shall be aluminum with block color finish. This compact signal amplifier supports magnetic isolation protection, protects the controllers and ensures that the DMX signal can be normally transmitted to various luminaires, improving the reliability and stability of the entire control system. The amplifier should have IP66 protection. The amplifier should able to transmit the DMX signal up to 100mtr or up to 64 luminaires with out signal loss. Operating temperature shall be -20° to 50°C. The maximum power consumption shall be less than 1.5W and input voltage shall be 12-24V DC.
3
-
-
Supply Installation Testing and Commissioning of IP 66 rated 12-24V, 45W SMPS to provide the input supply to DMX signal amplifier
3
-
-
Supply, installation, testing and commissioning of controller to author, configure, and control dynamic LED light shows for DMX lighting networks. The controller with two universe of DMX ports control up to 340 light addresses, Works as a stand-alone or computer-driven controller, Secure Digital (SD) card drive for flexible show storage , USB 2.0 interface for downloading shows and configuring from attached PC or Mac, Simple installation and wiring is required, Flexible, adaptable mounting options are expected, Should be provided with light show authoring software, Direct line voltage power supports 100 — 240 VAC , Six configurable effects — Using light show authoring software to select from six effects, adjust effect settings, such as color, speed, and brightness etc as reqd.
1
-
-
Supply Installation Testing and Commissioning of compact DMX signal amplifier that takes the incoming DMX512/RDM signal and amplify the signal and supporting bi-directional communications for discovery, addressing and DMX control of light fixtures.This unit takes the incoming DMX/RDM signal and splits the signal into six separate output channels allowing for expanding the number of devices controlled from 32 to 6 X 32. The output terminals are electronically isolated from the input & RDM-through port and share a common ground reference. All six output ports have an independent output driver to boost the DMX/RDM signal. Operating temperature shall be -10° to 35°C. The maximum power consumption shall be less than 4.5W and input voltage shall be 12-24V DC.
10
-
-
Supply Installation Testing and Commissioning of 10 pieces of 2mtr factory made male to female cable to connect the DMX enabled data line for better connectivity.
2
-
-
Supply Installation Testing and Commissioning of 10 pieces of 5mtr factory made male to female cable to connect the DMX enabled data line for better connectivity.
7
-
-
Supply Installation Testing and Commissioning of 10 pieces of 2mtr factory made female connector cable to connect the DMX enabled light fixture with the controller data line for better connectivity.
1
-
-
Supply Installation Testing and Commissioning of 20 pieces of factory made male/ female endcap to terminate the data network.
2
-
-
Supplying and laying/ Fixing of Flexible CAT 6 LAN cable on surface complete i/c connection, testing etc
200
-
-
Supplying and laying/ Fixing of Armoured CAT 6 LAN cable on surface complete i/c connection, testing etc
50
-
-
Supplying & laying/ Fixing the following sizes of PVC insulated, PVC Flexible Copper Cable of following sizes in the following manners complete i/c connection, testing with all accessories etc. as required .
-
-
-
4 x 16 sq.mm copper
80
-
-
2 x 2.5 sq.mm
80
-
-
3 x 2.5 sq.mm Armoured
50
-
-
3 x 2.5 sq.mm
1800
-
-
Supplying and laying the above wire in a insulated 40 mm Dia HDPE pipe.
100
-
-
Supplying and laying the above wire in a insulated 25 mm Dia HDPE pipe.
100
-
-
Supply and fixing of IP65 rated Cable Junction Boxes 6 x 4 inch for providing connectivity between luminaries and the supply line.
333
-
-
Supply and fixing of IP65 rated Cable Junction Boxes 4 x 4 inch for providing connectivity between luminaries and the data line.
18
-
-
Supply and fixing of IP65 rated enclosure box 12 x 8 inch for accomadating the DMX booster and providing to the device. It shall be provided with a single phase plug point inside the box.
10
-
-
Supply of 10A single pole MCB
333
-
-
Supply of four pole 40A MCB
2
-
-
Fabrication, supplying, installation and commissioning of outdoor rated and weather proof feeder pillar of suitable size with locking arrangement in front & back with rain cap cover suitable for 3 phase, 4 wire 415 volt 50Hz dust and vermin proof made with CRCA sheet duly compartmentalized. The panel should be supplied with 40kVA 3 phase SPD, 1KVA/600W UPS, MCCB, RCCB and 3 phase servo stabilizer. The stabilizer rating shall be two times of the connecting load. The panel should have separate protetcive enclosure for DMX controller, voltage stabilizer and other lighting accessories and to be free from dust and moisture. It should be supplied with minimum power point/ socket and necessary air ventilation fan and system. The panel and control equipments should be provided with proper chemical earthing. Termination of all cables and wires inside the panel should be done properly with lugs and to be tagged for instant identification. Keypad should be installed with proper back box. The supply to the controller inside the panel to be powered ON only through UPS. DB Panel and stabilizer to be placed minimum 2 feet above ground level to avoid safety hazards and water accumulation inside the panel as per technical specification.
1
-
-
Supply and Fixing of Chemical Earthing Electrode ( 50 mm Dia Copper Pipe, 1.6 mm Thick 3 mtr Long with 25bag 2 nosmoisture Booster bag ,installation charges and labour charges etc
2
-
-
Supply and Fixing of Lug for Cable End Termination
1000
-
-
Supplying and laying the wire in a PVC Trunking with the size of 50mm X 50mm and the trunking should have high impact resistance.
1000
-
-
Supply and installation of customized L shape clamp with channel for mounting the linear on the civil slap. The clamp should be made of GI with white powder coated material as per standard technical specification. Dimension shall be 1.47mtr length with two supporting L clamp.
177
-
-
Supply and installation of 1.2mtr mesh for protect the linear fixtures from unauthorize access.
8
-
-
Supply and installation of mesh to cover the 230 x 240 x 110mm size product. It should capable to protect the flood light fixtures from unauthorize access.
8
-
-
Supply and fixing of outdoor rated 18 way PVC distribution box.
4
-
-
Supply and Fixing of gland for proper cable entry and exit from junction box and other electrical boxes.
180
-
-
Supplying and laying the above wire in a 1 inch PVCbend pipe.
50
-
-
Supplying and laying the above wire in a 1 inch PVC pipe and the length of the pipe shall be 3mtr.
30
-
-
Operation and Maintenance
-
-
-
Routine, Preventive & Comprehensive Maintenance and Operation of entire DYNAMIC FACADE LIGHTING system comprising of all installed as per specifications & Schedule of work, including corrective maintenance resolution with dedicated Call center facility 24x7 hours with dedicated E-mail ID, telephone No. or with any other quick response facilities for quick response and effective maintenance and operation, all as per specific terms and conditions and direction of Engineer in-charge .
-
-
-
1st year
1
-
-
2nd year
1
-
-
3rd year
1
-
-
4th year
1
-
-
5th year
1
-
-
FIN BID FOR DYNAMIC LIGHTING - BHARATHY PARK , PONDICHERRY
-
-
-
Design Supply Installation Testing and Commissioning of circular RGB with neutral white LED flood light luminaire high power LED with housing material of extruded aluminium with die-cast aluminum end caps, dark grey anodized finish, system wattage should be less than or equal to 36W at full load and system lumen output of not less than 1500 lumens. Fixture shall be avilable with high power LED and architectural optics with choice of beam angles of Elliptical 35°- 40°x35°-40°. The luminaire shall be able to deliver 12lx at 50 ft from luminaire with a beam width of 34 ft in both horizontal and vertical plane. The luminarie peak intensity shall be minimum 4400Cd The luminaries shall be with Anti-aging and anti-UV high optical efficiency PMMA lens and clear tempered glass for better illumination. The white LED should have SDCM 4 for better color. Fixture dimension shall be not larger than 210mm dia and 160mm height without bracket and weight not more than 5.0kgs. Luminarie should have IP67 rated male/female connectors for DMX through wiring. Fixture shall operate in a temperature range of -40°C to 50°C and startup temperature range of -35°C to 50°C. Fixture shall have auto-ranging input voltage for 120 – 277 VAC. Lifetime should be at least 50,000 burning hours at L70 at 35 degree centigrade with total IP66 protection. Fixture shall equipped with mechanical impact of minimum IK06.
150
-
-
Supply Installation Testing and Commissioning of compact DMX signal amplifier that takes the incoming DMX512/RDM signal and amplify the signal into long distance transmission. The housing shall be aluminum with block color finish. This compact signal amplifier supports magnetic isolation protection, protects the controllers and ensures that the DMX signal can be normally transmitted to various luminaires, improving the reliability and stability of the entire control system. The amplifier should have IP66 protection. The amplifier should able to transmit the DMX signal up to 100mtr or up to 64 luminaries with out signal loss. Operating temperature shall be -20° to 50°C. The maximum power consumption shall be less than 1.5W and input voltage shall be 12-24V DC.
14
-
-
Supply Installation Testing and Commissioning of IP 66 rated 12-24V, 45W SMPS to provide the input supply to DMX signal amplifier
14
-
-
Supply, installation, testing and commissioning of controller to author, configure, and control dynamic LED light shows for DMX lighting networks. The controller with two universe of DMX ports control up to 340 light addresses, Works as a stand-alone or computer-driven controller, Secure Digital (SD) card drive for flexible show storage , USB 2.0 interface for downloading shows and configuring from attached PC or Mac, Simple installation and wiring is required, Flexible, adaptable mounting options are expected, Should be provided with light show authoring software, Direct line voltage power supports 100 — 240 VAC , Six configurable effects — Using light show authoring software to select from six effects, adjust effect settings, such as color, speed, and brightness etc as reqd.
1
-
-
Supply Installation Testing and Commissioning of compact DMX signal amplifier that takes the incoming DMX512/RDM signal and amplify the signal and supporting bi-directional communications for discovery, addressing and DMX control of light fixtures.This unit takes the incoming DMX/RDM signal and splits the signal into six separate output channels allowing for expanding the number of devices controlled from 32 to 6 X 32. The output terminals are electronically isolated from the input & RDM-through port and share a common ground reference. All six output ports have an independent output driver to boost the DMX/RDM signal. Operating temperature shall be -10° to 35°C. The maximum power consumption shall be less than 4.5W and input voltage shall be 12-24V DC.
1
-
-
Supply Installation Testing and Commissioning of 10 pieces of 2mtr factory made female connector cable to connect the DMX enabled light fixture with the controller data line for better connectivity.
3
-
-
Supply Installation Testing and Commissioning of 20 pieces of factory made male/ female endcap to terminate the data network.
1
-
-
Electrical Components
-
-
-
Supplying and laying/ Fixing of Armoured CAT 6 LAN cable on surface or conceled as required complete i/c connection, testing etc
600
-
-
Supplying & laying/ Fixing the following sizes of PVC insulated, PVC Flexible Copper Cable of following sizes in the following manners complete i/c connection, testing with all accessories etc. as required .
-
-
-
Shielded 4 x 2.5 sq.mm
3000
-
-
2 x 1.5 sq.mm
2000
-
-
Supplying and laying the above wire in a insulated 50 mm Dia HDPE pipe.
3000
-
-
Supplying and laying the above wire in a insulated 25 mm Dia HDPE pipe.
3000
-
-
Supply and Fixing of IP65 rated 12 way PVC distribution box with single number of 20A 4 pole MCB and 6 no's of 10A of single pole MCB.
25
-
-
Supply and fixing of IP65 rated enclosure box 12 x 8 inch for accomadating the DMX booster and providing to the device. It shall be provided with a single phase plug point inside the box.
18
-
-
Fabrication, supplying, installation and commissioning of outdoor rated and weather proof feeder pillar of suitable size with locking arrangement in front & back with rain cap cover suitable for 3 phase, 4 wire 415 volt 50Hz dust and vermin proof made with CRCA sheet duly compartmentalized. The panel should be supplied with 40kVA 3 phase SPD, 1KVA/600W UPS, MCCB, RCCB and 3 phase servo stabilizer. The stabilizer rating shall be two times of the connecting load. The panel should have separate protetcive enclosure for DMX controller, voltage stabilizer and other lighting accessories and to be free from dust and moisture. It should be supplied with minimum power point/ socket and necessary air ventilation fan and system. The panel and control equipments should be provided with proper chemical earthing. Termination of all cables and wires inside the panel should be done properly with lugs and to be tagged for instant identification. Keypad should be installed with proper back box. The supply to the controller inside the panel to be powered ON only through UPS. DB Panel and stabilizer to be placed minimum 2 feet above ground level to avoid safety hazards and water accumulation inside the panel as per technical specification.
1
-
-
Supply and Fixing of Chemical Earthing Electrode ( 50 mm Dia Copper Pipe, 1.6 mm Thick 3 mtr Long with 25bag 2 nosmoisture Booster bag ,installation charges and labour charges etc
2
-
-
Supply and Installation of single pole 10kA single phase SPD for individual luminaries for better safety from surges or spikes.
40
-
-
Supply and Installation of 4 pole 40kA three phase SPD for individual luminaries for better safety from surges or spikes.
1
-
-
Supply and Fixing of 50/ 25mm gland for proper cable entry and exit from junction box and other electrical boxes.
800
-
-
Supply and Fixing of Lug for Cable End Termination
200
-
-
Supply and Erection of 3mtr hot dip galvanized Pu coated steel tubular post along with circular shape bracket to mount 6 no's of fixture
25
-
-
Labour for laying of cable through HDPE pipe ( 50 mm and 25mm OD ) in floor and cement concrete including braking & Filling of floor with soil or cement concrete mix.
3000
-
-
Operation and Maintenance
-
-
-
Routine, Preventive & Comprehensive Maintenance and Operation of entire DYNAMIC FACADE LIGHTING system comprising of all installed as per specifications & Schedule of work, including corrective maintenance resolution with dedicated Call center facility 24x7 hours with dedicated E-mail ID, telephone No. or with any other quick response facilities for quick response and effective maintenance and operation, all as per specific terms and conditions and direction of Engineer in-charge .
-
-
-
1st year
1
-
-
2nd year
1
-
-
3rd year
1
-
-
4th year
1
-
-
5th year
1
-
-
Supply Installation testing and commissioning of all Luminaires, Drivers , controllers, relay design options and software components for design Option 1 as per the BOQ submitted at Annexure – 3 clause no 42.1. Complete work. Grand Total for Design Option 1 Chief Secretariat
1
-
-
Supply Installation testing and commissioning of all Luminaires, Drivers , controllers, relay design options and software components for design Option 2 (if any) as per the BOQ submitted at Annexure – 3 Clause .no 42.2 . Complete work. Grand Total for Design Option 2 Chief Secretariat
1
-
-
Supply Installation testing and commissioning of all Luminaires, Drivers , controllers, relay design options and software components for design Option 1 as per the BOQ submitted at Annexure – 3 clause no 42.1. Complete work. Grand Total for Design Option 1
1
-
-
Supply Installation testing and commissioning of all Luminaires, Drivers , controllers, relay design options and software components for design Option 2 (if any) as per the BOQ submitted at Annexure – 3 Clause .no 42.2 . Complete work. Grand Total for Design Option 2
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements