Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
2 TR Nominal Capacity - 800 CFM

1

-

-

... More
Supply, installation, testing and commissioning of Air Cooled High Wall mounted Split type Air Conditioner (inverter type) of following capacity consisting of high wall mounted type room unit (fan coil) with cordless remote control and outdoor condensing unit comprising of enegy efficient suitable rotary compressor for operation on single phase, 230 V, 50Hz supply, fixing the outdoor unit on a raised platform as per manufacturers recommendation and fixing of room (fan coil) unit on wall, standard 3.5 m distance refrigerant copper piping with 13mm nitrile rubber insulation, providing and making interconnection between room & condenser as per site conditions, comprising of full electrical cabling from power plug near indoor unit and to outdoor unit, ODU MS stand, with suitable bolts, nuts, clamps, making holes on walls, plastering etc., as per site requirement, first charge refrigarant gas (R410-A/R407-C/R32), complete as required.

-

-

-

... More
1.5 TR 5 star rated as per BEE

1

-

-

... More
Supply, installation, testing and commissioning of copper refrigerant piping with 13 mm thick nitrile rubber insulation interconnecting the Condensing unit to evaporating unit for split units as per site condition

-

-

-

... More
Copper refrigerant piping for 2 TR Cassette unit of suitable size 5/8" & 3/8".

15

-

-

... More
Copper refrigerant piping for 1.5 TR Split AC of suitable size 1/2" & 1/4".

15

-

-

... More
Voltage Stabilizer 4 KVA rating suitable for 1.5TR Split AC Units with Overcurrent & Under voltage protection. (The input voltage is 230V ± 10% AC 50 c/s)

1

-

-

... More
Voltage Stabilizer 5 KVA rating suitable for 2TR Cassette AC Units with Overcurrent & Under voltage protection. (The input voltage is 230V ± 10% AC 50 c/s)

1

-

-

... More
Supply and installation of 20A-25A 3 pin metal clad plug and socket with 20A-25A MCB with suitable powder coated sheet steel enclosure with fixing accessories etc

2

-

-

... More
Supply and installation of PVC drain pipe with 6mm nitrile rubber insulation ISI marked, connecting the drain lines from the indoor units to floor sump to be concealed or to be laid as per site required with as may be decided by Engineer-in-charge.

-

-

-

20

-

-

40

-

-

... More
Dismantling and Modification of Existing ducts of various size, collars, elbows, gaskets, hangers, supports etc. as required

1

-

-

... More
Supplying, installation, testing and commissioning of Exhaust Inline fan of 600 CFM capacity. The work includes making holes in walls by making smooth cement finish etc., as required

1

-

-

... More
Cleaning & Sanitizing of CSU's with approved chemical by dismantling coil sections (if necessary) applying and rinsing with an acceptable biocides / chemicals and high pressure cleaning with water, straigtening fins by utilizing a coil combing system, cleaning of drain pans & lines etc and refixing the coils. Vacuuming, hand scraping, cleaning of fans and motors by removing debris from fan impellers, blower blades and its housing.

-

-

-

... More
Ceiling suspended units

2

-

-

... More
Supplying, installation, testing and commissioning of External thermal insulation on supply air ducts using min 9mm thick nitrile rubber class"O"closed cell type with anti microbial protection as per specifications

28.3

-

-

... More
Supplying and fixing of flexible connection made out of fire-retardant, lint-free double canvass connections of heavy gauge of required sizes for CSU's with necessary bolt, nut, screws, gaskets etc (if required)

2

-

-

... More
PART - B (Walk-In-Cold room)

-

-

-

... More
Supplying, Testing and Commissioning of Walk-In-Cold room of temperature to be maintained between 0°C to 4°C with Standard RH Level, Room size External: 2.44 m (D) x 2.44 m(W) x 2.44 m (H) Prefab modular PUF panels of thickness 60mm on all sides including floor with SS/SS sheet cladding on both sides and PUF panel with thickness 0.4 mm, one number door openings, Floor Panel 60mm Thick, Floor PP Outer 6mm Marine PLY- 1.2 MM AL.Chaqured Plate as per detailed specifications and requirements, Internal lighting with limit Switch to control lighting inside cold room.

1

-

-

... More
Supplying, Installation, Testing and Commissioning of Air-cooled condensing unit with suitable capacity, hermetically sealed compressor complete with condenser coil, blower, motor and all other safety and control accessories in outdoor enclosure for 1.5Tr Outdoor unit model and Evaporator coil with suitable capacity cooling coil, fan and all other safety and control accessories as required. (Make: Bluestar)

2

-

-

... More
Supplying and fixing of twin copper refrigerant pipeline for liquid line and gas duly insulated with nitrile foam rubber, including complete from indoor unit to outdoor unit as required.

30

-

-

... More
Supplying & laying of Suitable size PVC insulated copper cable for power and control wiring / Light connection wiring & indoor to outdoor communication wiring for tightly wrapped with packing tape, providing necessary clamps/supports etc

45

-

-

... More
Supplying and fixing of Weather Proof Bell Bush Switch / Hooter Alarm and by providing necessary Accessories.

1

-

-

... More
Supplying and fixing of of Heavy duty-powder coated Stand for the outdoor unit with necessary Accessories as required.

1

-

-

... More
Supplying, Installation, Testing and Commissioning of Timer with its controls complete assembly with necessary acessories

1

-

-

... More
Labour Charges for Shifting of Cold Room Panels, Indoor & Outdoor Units from Ground floor to 2nd Floor which also includes Transportation charges.

1

-

-

... More
Labour Charges for Installation of Cold Room Panels.

384

-

-

... More
PART - C (Clean Room - Class 10000)

-

-

-

... More
Ceiling Suspended Fan Filter Unit: Supplying & Fixing of ceiling suspended type fan filter unit made up of GI sheet with powder coated finish construction. The fan filter unit consists of a 10micron pre filter, blower, 0.3 micron HEPA filter and SS304 perforated diffusers with the provisions for suspending from ceiling. The blower is designed to provide 90 to 120 FPM of air velocity. Dimensions For Room I: 9 feet X 9.5 feet & Room II: 10 feet X 9 feet, FFU size: L 4 x W 2 x H 2 Feet, Capacity : 600 CFM

4

-

-

... More
Return Air Riser Panel: Supplying & Fixing of return air riser panels made up of 1.2 mm thick GI sheet with powder coated finish. The return air riser will be fixed in the corners of the room and has the provision for to connect the flexible hose and dampers. Dimension: W 1.5 x H 8 feet

8

-

-

... More
Flexible Hose: Supplying & Fixing of insulated flexible hose between return air riser and fan filter unit. Dia : 8 inches

30

-

-

... More
GI Butterfly dampers: Supply & Fixing of GI butterfly dampers in the return air riser panel collar and fan filter unit collar in order to adjust the volume of Air.

16

-

-

... More
Pre Filter & SS304 diffuser for Return air riser: Supply & Fixing of 10 micron pre filter and SS304 perforated diffuser in the return air riser panel. Dimension : W 1.2 x H 1.2 feet

8

-

-

... More
Walkable steel panel false ceiling: Supplying & fixing of 50mm thick double skin .PUFF panel enclosure for return air riser: Supply & fixing of 50mm thick double-skin PUFF panel as an enclosure for PUFF panel with the above specifications.

244

-

-

... More
Supplying and Fixing of Electrical Control panels to Turn ON/OFF the Fan filter units which includes Electrical cabling from control panels to FFU's.

2

-

-

... More
Air Curtain with Limit Switch: Supplying & Fixing of air curtains with automatic On/Off (Limit switch) while opening and closing the doors of each cleanrooms. Dimension: 1220 x 225 x 225 mm. Model : High Velocity series

2

-

-

... More
Miscellaneous Charges: Charges towards the packing, loading, freight of materials and unloading at the site as required.

1

-

-

... More
Supply, installation, balancing and commisnioning of site fabricated GSS sheet metal ducts rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter, dampers, vanes, hangers, supports etc as per approved drawings & specification of following sheet thickness

-

-

-

... More
Thickness 0.63mm sheet

36

-

-

... More
Supplying, Fixing, Testing and Commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core.

0.37

-

-

... More
Supplying, Fixing, Testing and Commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core.

1.87

-

-

... More
Total Amount in figures :

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.