Higher And Technical Education Department Tender
View complete overview of Puducherry DHTE Tender
Higher And Technical Education Department - DHTE Tender
Civil And Construction
Education And Training Services
Eprocure
Opening Date3 Oct 2024
Closing Date14 Oct 2024
Tender AmountRefer Documents
Costs
EMD
₹ 1,25,700Document Cost
₹ 1,050Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_DHTE_16646_1Tender No
PTU/BD/62/2024-25Tender Authority
Higher And Technical Education Department ViewPurchaser Address
-Website
http://pudutenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Code No 2.27A.1 Supplying and filling with gravel (excluding rock) in trenches, plinth,sides of foundations etc.in layers not exceeding 20cm in depth consolidating each deposited layers by ramming and watering etc.complete including all lead and lift.
90
-
-
Code No 2.31 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared.
440
-
-
Code No 2.33.2 Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches removing the roots and stacking of serviceable material and disposal of unserviceable material - Beyond 60 cm girth upto and including 120 cm girth.
5
-
-
Code No 4.1.10 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering.- All work upto plinth level -1:5:10 (1 cement:5coarse sand : 10 graded stone aggregate 40mm nominal size)
35
-
-
Code No 5.1.2 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement -All work upto plinth level : 1:1.5:3 (1 cement : 1 .5 coarse sand : 3 graded stone aggregate 20mm nominal size)
27
-
-
Code No 5.2.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters , buttresses, plinth and string courses , fillets, columns , pillars, piers, abutments, posts and struts etc.upto floor five level excluding cost of centering, shuttering,finishing and reinforcement:1:1.5:3 (1 cement : 1.5coarse sand : 3 graded stone aggregate 20mm nominal size)
9.5
-
-
Code No 5.2.3 Reinforced cement concrete work in walls (any thickness) , including attached pilasters, buttresses , plinth and sting courses , fillets , columns , pillars ,piers , abutments , posts and struts etc. upto floor five level excluding cost of centering , shuttering , finishing and reinforcement - 1:2:4 (1 cement : 2coarse sand :4 graded stone aggregate 20mm nominal size)
1.5
-
-
Code No.5.33.2: Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work , using cement content as per approved design mix , including pumping of concrete to site of laying but excluding the cost of centering , shuttering ,finishing and reinforcement , including admixtures in recommended proportions as per IS : 9103 to accelerate, retard setting of concrete , improve workability without impairing strength and durability . Note:- Cement content considered in this item is @ 330 kg / cum. Excess or less cement used as per design mix is payable or recoverable separately. - All work above plinth level upto floor V level
66
-
-
Code No.5.34.1: Extra for providing richer mixes at all floor levels - Note:- Excess / less cement over the specified cement content used is payable / recoverable separately -Providing M-30 grade concrete instead of M-25 grade BMC / RMC . (Note:- cement content considered in M-30 is @ 340 kg / cum)
66
-
-
Code No. 5.9.1 Centring and shuttering including strutting, propping etc.and removal of form for:Foundations , footings, bases of columns ,etc. for mass concrete.- Using steel sheet with M.S.frames
42
-
-
Code No 5.9.5 Centring and shuttering including strutting, propping etc. and removal of form for: lintels, beams, plinth beams, girders, bressumers and cantilevers.- Using steel sheet with M.S.frames
262
-
-
Code No 5.9.6 Centring and shuttering including strutting, propping etc. and removal of form for: columns, pillars, piers, abutments, posts and struts.- Using steel sheet with M.S.frames
151
-
-
Code No 5.9.3 Centering and shuttering including strutting , propping etc and removal of form for - Suspended floors , roofs , landings , balconies and access platform
281
-
-
Code No 5.9.7 Centering and shuttering including form for - Stairs , (excluding landings) except spiral -staircases strutting , propping etc and removal of form for - Stairs , (excluding landings) except spiral -staircases
9
-
-
Code No 5.9.19 Centering and shuttering including strutting , propping etc and removal of form for -Weather shade , Chajjas, corbels etc., including edges
23
-
-
Code No.5.22.10: Providing and placing M30 grade cover block for RCC work all levels
8500
-
-
Code No 5.22.6 Steel reinforcement for R.C.C.work including straightening , cutting , bending , placing in position and binding all complete upto plinth level - Thermo -Mechanically treated bars (TISCON / VIZAG / IISCO / SAIL / JSW) Fe - 415 or more
3200
-
-
Code No 5.22A.6 Steel reinforcement for R.C.C.work including straightening , cutting , bending , placing in position and binding all complete above plinth level - Thermo - Mechanically Treated bars (TISCON / VIZAG / IISCO / SAIL / JSW) Fe - 415 or more
10600
-
-
Code No 6.1.1 Brick work with FPS bricks of class designation 35 in foundation and plinth in cement mortar 1:4 (1 cement : 4 coarse sand)
11
-
-
Code No 6.4.1 Brick work with FPS bricks of class designation 35 in superstructure above plinth level upto floor V level in all shapes and sizes in cement mortar 1:4 (1cement: 4 coarse sand)
73
-
-
Code No.9.121 Providing and fixing Fiber glass reinforced Plastic (FRP) door frames of cross section 90mm x 45mm having single rebate of 32mm x 15mm to receive shutter of 30mm thickness. The laminate shall be molded with fire resistant grade unsaturated polyester resin and chopped mat. Doorframe laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fibreglass from all sides. MS stay shall be provided at the bottom to steady the frame
5.5
-
-
Code No 9.122.1 Providing and fixing to existing door frames - 30mm thick glass fibre reinforced plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5mm thick FRP laminate for panels conforming to TADS 6: 1993 and / or IS : 14856 - 2000 including fixing to frames.
2.1
-
-
Code No.9.71.1 Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete : - 125x64x2.50mm
20
-
-
Code No 9.147D.3 Providing and fixing factory made UPVC white colour sliding glazed window upto 1.50m in height dimension comprising of uPVC multi - chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 + or - 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile , zinc alloy (white powder coated) touch locks with hook , zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I. fastners 100 x8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shyall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc.After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality , all complete as per approved drawing.(Single / double glass panes , wire mesh and silicon sealent shall be paid separately) - Two track two panels sliding window made of (bigl series) frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 + or - 0.2 mm and single glazing bead / double glazing bead of appropriate dimension.(Area of window upto 1.75 sqm upto 2.50 sqm) - sliding window size 1.50x1.35 m
27
-
-
Code No 9.96.1 Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with nuts and screws etc. complete:-300x16mm
6
-
-
Code No 9.97.3 Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc.complete :- 200x10mm
8
-
-
Code No 9.100.1 Providing and fixing aluminium handles , ISI marked , anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade,with necessary screws etc, complete - 125 mm
8
-
-
Code No 9.165.1B Providing and fixing of 65 mm Godrej Navatal lock of 7 levers with 3 keys etc complete.
5
-
-
Code No.10.16.1 Steel work in built up tubular trusses including cutting, hoisting fixing in position and applying a priming coat of approved steel primer welded and bolted including special shaped washers etc. complete. Hot finished welded type tubes.
235
-
-
Code No.10.18 Providing and fixing circular/hexogonal cast iron or M.S. sheet box for ceiling fan clamp of internal dia 140mm, 73mm height, top lid of 1.5mm thick M.S. sheet with its top surface backed for proper bonding, top lid shall be screwed in to the cast iron/M.S. sheet box by means of 3.3mm dia. Round headed screws, one lock at the corners. Clamp shall be made of 12mm dia M.S. bar bent to shape as per standard drawing.
17
-
-
Code No. 10.25.2 : Steel work welded in built up sections / framed work , including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required - in gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
720
-
-
Code No 11.41.2A Providing and laying fully vitrified floor tiles of size 600 x600 mm (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622 of approved make (Nitco / Rak / Johnson /Asian ) in all colours and shades , laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) , including grouting the joints with white cement and matching pigments etc., complete - size of tile 600 x600 mm
240
-
-
Code No 11.48.2 Grouting the joints of flooring tiles having joints of 3mm width, using epoxy grout mix of 0.70kg of organic coated filler of desired shade (0.10kg of hardener and 0.20 kg of resin per kg) , including filling / grouting and finishing complete - size of tile 600x600 mm .
240
-
-
Code No 11.50 Deduct for not grouting the joints with white cement and matching pigment in the items of fixing of vitrified tiles
240
-
-
Code No.12.8: Providing non-asbestos high impact polypropylene reinforced cement 6mm thick corrugated sheet (as per IS : 14871) roofing upto any pitch and fixing with pollymer coated J or L hooks, bolts and nuts 8mm dia. G.I. plain and bitumen washers or with self drilling fastener and EPDM washers etc., complete excluding the cost of purlins, rafters and trusses corrugated sheets and including cutting to size and shape wherever required.
36
-
-
Code No 12.15.1 Painting top of roofs with bitumen of approved quality at 17kg per 10sqm impregnated with a coat of coarse sand at 60 cudm per 10 sqm including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete: With residual type petroleum bitumen of penetration 80/100.
267
-
-
Code No 12.20L Lime concrete terracing on roofs of required thickness laid to fall with 25mm nominal size brick aggregate and 50% lime mortar 1:2 (1 lime putty : 2 surkhi) rammed and finished with gur and belgiri treatment complete including rounding of junctions with Parapet wall complete
27
-
-
Code No 12.41.2 Providing and fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion, (i) Single socketed pipes - 110 mm diameter
33
-
-
Code No 12.42.5.2 Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion - bend 87.5 degree - 110 mm bend
8
-
-
Code No 12.42.6.2 Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion - shoe (plain) - 110mm shoe
8
-
-
Code No. 12.43.2 Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised- PVC rain water pipes by means of 50x50x50mm hard wood plugs , screwed with M.S. screws of required length, including cutting brickwork and fixing in cement mortar 1:4 ( 1 cement : 4 coarse sand) and making good the wall etc., complete - 110mm
40
-
-
Code No 12.53 Providing and fixing 15mm thick densified regular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture spintone / cosmos /Hexa or equivalent of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main 'T' runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre , and cross 'T" of size 24 x28 mm made out of 0.33 mm (minimum) sheet, 1200 mm long spaced between main 'T' at 600 mm centre to centre to form a grid of 1200 x600 mm and secondary cross 'T' of length 600 mm and size 24x28 mm made of 0.33 mm thick (minimum) sheet to be inter locked at middle of the 1200x600mm panel to from grid of size 600x600 mm, resting on periphery walls / partitions on a perimetre wall angle pre-coated steel of size 24x24x3000 mm made of 0.4mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230mm interval and laying 15mm thick densified edges calcium silicate ceiling tiles of approved texture (Spintone /Cosmos/hexa) in the grid, including , cutting / making opening for services like diffusers , grills, light fittings, fixtures , smoke detectors etc., wherever required. Main 'T' runners to be suspended from ceiling using G.I.slotted cleats of size 25x35x1.6mm fixed to ceiling with 12.5mm dia and 50mm long dash fasteners, 4mm G.I.adjustable rods with galvanised steel level clips of size 85x30x0.8mm, spaced at 1200mm centre to centre along main 'T' , bottom exposed with 24mm of all T-sections shall be pre -painted with polyster baked paint, for all heights, as per specifications, drawings - Note:- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut out) having area less than 0.30 sqm. The calcium silicate ceiling tile shall have NRC , value of 0.50(minimum), light reflection 85% ,non - combustible as per B.S.476 Part IV, 100% humidity resistance and also having thermal conductivity 0.043 w/m 0 KC
191
-
-
Code No 12.55 Providing and fixing heat resistant terrace tiles (300mm x 300mm x 20mm) with SRI (solar refractive index) 78, solar reflection 0.70 and initial emittance 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete , including providing skirting upto 150mm height along the parapet walls in the same manner
267
-
-
Code No 13.1.1 12mm cement plaster of mix :Cement mortar 1:4 (1 cement : 4 fine sand)
455
-
-
Code No 13.2.1 15 mm cement plaster on rough side of single or half brick wall of mix - cement mortar 1:4 (1 cement : 4 fine sand)
335
-
-
Code No 13.16.1 6mm cement plaster of mix 1:3 (1 cement : 3 fine sand).
405
-
-
Code No 13.48.1 Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications - Two or more coats applied @ 1.25 ltr / 10 sqm over and including one coat of special primer applied @ 0.75 ltr / 10 sqm.
1400
-
-
Code No 13.52.1 Finishing with epoxy paint (two or more
coats) at all locations prepared and applied as per manufacturer specifications including appropriate priming coat, preparation of surface, etc. complete - On Steel work.
40
-
-
Code No 16.2.1 Making plinth protection with bricks of class designation 7.5 laid on edge in cement mortar 1:6 (1 cement : 6 coarse sand) with 12 mm thick bed of cement mortar 1:6 ( 1 cement : 6 coarse sand) over 75 mm bed of dry brick aggregate 40mm nominal size rammed. Consolidated and grouted with fine sand and the top of bricks pointed with cement mortar 1:3 (1 cement : 3 fine sand)
37
-
-
Code No 21.1.1.3 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate Z sections and other sections of approved make conforming to IS:733 and IS: 1285, fixing with dash fasteners of required dia and size,including necessary filling up the gaps at junctions , i.e at top, bottom and sides with required EPDM rubber / neoprene gasket etc. Aluminium sections shall be smooth,rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling , C.P.brass / stainless steel screws , all complete as per architectural drawings (Glazing, paneling and dash fasteners to be paid for separately) - for fixed portion - Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron)
500
-
-
Code No 21.1.2.2 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate Z sections and other sections of approved make conforming to IS:733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions , i.e at top, bottom and sides with required EPDM rubber / neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling , C.P.brass / stainless steel screws , all complete as per architectural drawings (Glazing, paneling and dash fasteners to be paid for separately) - for shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (fittings shall be paid for separately) - Powder coated aluminium (minimum thickness of powder coating 50 micron)
55
-
-
Code No 21.3.1 Providing and fixing glazing in aluminium door, window , ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings ( cost of aluminium snap beading shall be paid in basic item) - with float glass panes of 4.0 mm thickness
27
-
-
Code No 21.3.2 Providing and fixing glazing in aluminium door, window , ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings ( cost of aluminium snap beading shall be paid in basic item) - with float glass panes of 5.50 mm thickness
18
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements