Electricity Department Tender
View complete overview of Puducherry Electricity Department Tender
Electricity Department Tender
Eprocure
Opening Date3 Jul 2020
Closing Date20 Jul 2020
Tender Amount₹ 29,96,548 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 1,24,067Document Cost
₹ 1,180Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2020_HDPOW_6329_1Bid Award Id
ViewTender No
e.No.01/ED/EE-SPM and Bldgs./2020-21Tender Authority
Electricity Department ViewPurchaser Address
-Website
http://pudutenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
H.T. Rod (Brass) with Metal parts (Brass) (IS 3347) for 200 KVA
3
-
-
... More
L.T. Rod copper with Metal parts Brass each (IS. 3347) for 200 KVA
4
-
-
... More
Breather for 200 KVA
1
-
-
... More
Wheel valve of size 1 ¼”each (superior quality) for 200 KVA
1
-
-
... More
New Transformer Oil per litre conforming I.S. No.335-1993 with latest amendments for 200 KVA
300
-
-
... More
C.R.G.O Lamination for 200 KVA
0.5
-
-
... More
Radiator Fins for 200 KVA
1
-
-
... More
Inter coil Insulation per limb for 200 KVA
3
-
-
... More
Re-insulation of L.V. Coils for 200 KVA
102
-
-
... More
Oil Resistance Paint for inner side of Tanks per Transformer for 200 KVA
2
-
-
... More
Gray Paint for outer side of Distribution Transformer for 200 KVA
2
-
-
... More
Gasket for tank cover / Transformer for 200 KVA
1
-
-
... More
Loading of Distribution Transformers at Department site, Transportation and unloading Distribution Transformers at Factory site per Transformer for 200 KVA
1
-
-
... More
Opening, lifting the core and re-Examination: Per Transformer for 200 KVA
1
-
-
... More
Positioning the core back after repair, and complete electrical connection, replacing gaskets and boxing up with top cover for each repairable Transformer for 200 KVA
1
-
-
... More
Electrical connections: Star Connection for 200 KVA
1
-
-
... More
Electrical connections : Delta Connection for 200 KVA
1
-
-
... More
Cleaning tank, tubes, conservator tank etc., internal surface of and make them fit for use and painting with oil resistive paint excluding cost of paint per transformer for 200 KVA
1
-
-
... More
Cleaning, scraping the external surface of the transformer and painting with good quality Siemens grey paint with two coats excluding cost of paint per transformer for 200 KVA
1
-
-
... More
Charges for hot oil circulation after filling for 200 KVA
300
-
-
... More
Drying out of the repaired core after assembling the coils for 200 KVA
1
-
-
... More
Welding per cm for 200 KVA
90
-
-
... More
Sub-total
1
-
-
... More
HV Coil SE Copper / Kg for 315 KVA
199.08
-
-
... More
H.T. Bushings Insulator (I.S. 3347 ) for 315 KVA
3
-
-
... More
L.T. Bushings Insulator(I.S. 3347) for 315 KVA
4
-
-
... More
H.T. Rod (Brass) with Metal parts (Brass) (IS 3347) for 315 KVA
3
-
-
... More
L.T. Rod copper with Metal parts Brass each (IS. 3347) for 315 KVA
4
-
-
... More
Breather for 315 KVA
1
-
-
... More
Wheel valve of size 1 ¼”each (superior quality) for 315 KVA
1
-
-
... More
New Transformer Oil per litre conforming I.S. No.335-1993 with latest amendments for 315 KVA
535
-
-
... More
C.R.G.O Lamination for 315 KVA
0.5
-
-
... More
Radiator Fins for 315 KVA
1
-
-
... More
Inter coil Insulation per limb for 315 KVA
3
-
-
... More
Re-insulation of L.V. Coils for 315 KVA
96.9
-
-
... More
Oil Resistance Paint for inner side of Tanks per Transformer for 315 KVA
2
-
-
... More
Gray Paint for outer side of Distribution Transformer for 315 KVA
2
-
-
... More
Gasket for tank cover / Transformer for 315 KVA
1
-
-
... More
Loading of Distribution Transformers at Department site, Transportation and unloading Distribution Transformers at Factory site per Transformer for 315 KVA
1
-
-
... More
Opening, lifting the core and re-Examination: Per Transformer for 315 KVA
1
-
-
... More
Positioning the core back after repair, and complete electrical connection, replacing gaskets and boxing up with top cover for each repairable Transformer for 315 KVA
1
-
-
... More
Electrical connections: Star Connection for 315 KVA
1
-
-
... More
Electrical connections : Delta Connection for 315 KVA
1
-
-
... More
Cleaning tank, tubes, conservator tank etc., internal surface of and make them fit for use and painting with oil resistive paint excluding cost of paint per transformer for 315 KVA
1
-
-
... More
Cleaning, scraping the external surface of the transformer and painting with good quality Siemens grey paint with two coats excluding cost of paint per transformer for 315 KVA
1
-
-
... More
Charges for hot oil circulation after filling for 315 KVA
535
-
-
... More
Drying out of the repaired core after assembling the coils for 315 KVA
1
-
-
... More
Welding per cm for 315 KVA
50
-
-
... More
Sub-total
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements