Department Of Local Administration Tender
View complete overview of Puducherry DLA Tender
Department Of Local Administration - DLA Tender
Civil And Construction
Building Construction
Eprocure
Opening Date14 Aug 2024
Closing Date23 Aug 2024
Tender Amount₹ 71,74,395
Costs
EMD
₹ 1,43,488Document Cost
₹ 1,050Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_DLA_15734_3Bid Award Id
ViewTender No
OM/e-tenders/002/2024-25Tender Authority
Department Of Local Administration ViewPurchaser Address
-Website
http://http://www.dla.go.th/en/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Construction of houses to the tribal community in Anaikarai street Shanmugapuram in Kadhirkamam Constituency
Construction of houses to the tribal community in Anaikarai street Shanmugapuram in Kadhirkamam Constituency
BOQ Items
Code No. 2.27A.1
Supplying and filling with gravel (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering etc., completed including all leads and lift .
83
-
-
Code No. 4.1.10
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plinth level - 1:5:10 (1 cement : 5 Coarse sand : 10 grade stone aggregate 40mm nominal size)
35
-
-
Code No. 5.1.2
Providing and laying in position specified grade of reinforced cement concrete ,excluding the cost of centering ,shuttering , finsishing and reinforcement -All work upto plinth level 1:1.5:3 (1cement :1.5 coarse sand : 3 graded stone aggregate 20mm nominal size)
28
-
-
Code No. 5.2.2
Reinforced cement concrete work in walls (any thickness) , including attached pilasters, buttresses , plinth and sting courses , fillets , columns , pillars ,piers , abutments , posts and struts etc.upto floor five level excluding cost ofcentering , shuttering , finishing and Reinforcement - 1:1.5:3 (1 cement: 1.5coarse sand: 3 graded stone aggregate 20mm nominal size).
14.5
-
-
Code No. 5.3.1(PSR2013-14)&SE appd rate based on PSR (2020-21) basic rates)
Reinforced cement concrete work in beams, suspended floors , roofs having slope up to 15degree landings , balconies , shelves , chajjas , lintels , bands , plain window sills , staircases and spiral stair cases upto floor five level excluing the cost of centering ,shuttering, finishing and reinforcement , with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size)
57.5
-
-
Code No. 5.9.3
Centering and shuttering including strutting , propping etc and removal of form for - Suspended floors , roofs , landings , balconies and access platform.
262
-
-
Code No 5.9.5
Centering and shuttering including strutting , propping etc and removal of form for - Lintels , beams , plinth beams , girders , bressumers and catilevers
1381
-
-
Code No. 5.9.6
Centering and shuttering including strutting , propping etc and removal of form for - Columns , Pillars , Piers , Abutments , Posts and Struts
291
-
-
Code No. 5.22A.6
Steel reinforcement for R.C.C.work including straightening , cutting , bending , placing in position and binding all complete above plinth level - Thermo - Mechanically Treated bars (TISCON / VIZAG / IISCO / SAIL / JSW) Fe - 415 or more
9897
-
-
Code No. 5.23
Smooth finishing of the exposed surface of RCC work with 6mm thick cement mortar 1:3 ( 1 Cement : 3 Fine Sand )
448
-
-
Code No. 6.1.2 ( Addendum)
Brick work with common burnt clay F.P.S. (non modular ) bricks of class designation 3.5 in foundation and plinth in - cement mortar 1:6 (1 cement : 6 coarse sand)
41
-
-
Code No.6.4.2 ( Addendum)
Brick work with common burnt clay F.P.S (non modular ) bricks of class designation 3.5 in superstructure above plinth level upto floor five level in all shapes and sizes in - cement mortar 1:6 ( 1 cement : 6 coarse sand).
126
-
-
Code No. 6.13.2
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 3.5 in superstructure above plinth level upto floor V level - cement mortar 1:4 (1 cement : 4 coarse sand)
101
-
-
Code No. 6.15
Extra for providing and placing in position 2 nos 6mm dia M.S.bars at every third course of half brick masonry
101
-
-
Code No. 9.1.2P
Providing wood work in frames of doors , windows, clerestory windows and other frames , wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately) -Padak wood
1.1
-
-
Code No. 9.6.1
Providing and fixing 35mm thick factory made laminated veneer lumber door shutter conforming to IS : 14616 and TADS 15 : 2001 (Part B) , including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, all complete and panelling with panels of -12mm thick plain grade -1 , medium density flat pressed three layer particle board FPT - I or graded wood particle board FPT -I, IS :3087 marked , bonded with BWP type synthetic resin adhesive as per IS : 848
40
-
-
Code No. 9.63.1
Providing and fixing ISI marked oxidised M.S. tower bolt black finish (Barrel type) with necessary screws etc.complete -250x10mm.
31
-
-
Code No. 9.63.3
Providing and fixing ISI marked oxidised M.S. tower bolt black finish (Barrel type) with necessary screws etc.complete -150x10mm.
62
-
-
Code No. 9.81.1
Providing and fixing bright finished brass handles with screws etc complete - 125 mm
40
-
-
Code No. 9.95.1
Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour orshade with necessary screws etc.complete -125 X 75 X 4 mm.
57
-
-
Code No. 9.117.1
Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance +_1mm ), with wall thickness 2.0 mm (+-0.2mm) , corners of the door frame to be jointed with galvanized brackets and stainless steel screws , joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S.tube of size 19 x 19 mm and 1mm (+-0.1mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer's specification - Extruded section profile size 48 x 40 mm.
60
-
-
Code No. 9.118.1
Providing and fixing to existing door frames - 24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59 x 24 mm and wall thickness 2 mm (+- 0.2 mm) with inbuilt edging on both sides . The styles and rails mitred and joint at the corners by means of M.S. galvanised / plastic brackets of size 75 x 220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S.tube of size 20x20 mm and 1mm (+- 0.1mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100 x 24 mm and 2 mm (+-0.2 mm) wall thickness, fixed to the shutter styles by means of plastic / galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multichambered single panel of size not less than 620 mm, having overall thickness of 20 mm and 1 mm (+_ 0.1mm) wall thickness . They panels filled vertcally and tie bar at two places by inserting horizontally 6 mm galvanised M.S.rod and fastened with nuts and washers , complete as per manufacturer's specification (For W.C. and bathroom door shutter)
19
-
-
Code No. 9.147D.1
Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50m in height dimension comprising of uPVC multi - chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 + or - 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile , zinc alloy (white powder coated) touch locks with hook , zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I. fastners 100 x8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shyall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc.After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality , all complete as per approved drawing.(Single / double glass panes , wire mesh and silicon sealent shall be paid separately) - Two track two panels sliding window made of (small series) frame 52 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 + or - 0.2 mm and single glazing bead of appropriate dimension.(Area of window upto 1.75 sqm) - sliding window size 1.20x1.35 m
46
-
-
Code No. 9.165.1B
Providing and fixing of 65 mm Godrej Navatal lock of 7 levers with 3 keys etc complete
6
-
-
Code No. 10.25.1
Steel work welded in built up sections / framed work , including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required - in stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required all complete
1988
-
-
Code No. 11.3.1
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc .complete - 40mm thick with 20mm nominal size stone aggregate
222
-
-
Code No. 11.22.1.1
Tile work in skirting, risers of steps and dado upto 2 m height ,over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry @ 3.3 kg / sqm, including pointing in white cement mixed with pigment of matching shade complete - marble tiles (polished) Raj nagar - 8mm thick
65
-
-
Code No. 12.20
Providing and laying pressed clay tiles (as per approved pattern 18mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound , laid over a bed of 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete
205.5
-
-
Code No. 12.20L
Lime concrete terracing on roofs of required thickness laid to fall with 25mm nominal size brick aggregate and 50% lime mortar 1:2 (1 lime putty : 2 surkhi) rammed and finished with gur and belgiri treatment complete including rounding of junctions with Parapet wall complete.
18
-
-
Code No. 12.41.2
Providing and fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion, (i) Single socketed pipes - 110 mm diameter.
73
-
-
Code No. 12.42.5.2
Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion - bend 87.5 degree - 110 mm bend
18
-
-
Code No. 12.42.6.2
Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10mm gap for thermal expansion - shoe (plain) - 110mm shoe
18
-
-
Code No. 12.43.2
Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised- PVC rain water pipes by means of 50x50x50mm hard wood plugs , screwed with M.S. screws of required length, including cutting brickwork and fixing in cement mortar 1:4 ( 1 cement : 4 coarse sand) and making good the wall etc., complete - 110mm
72
-
-
Code No. 13.8.3
12 mm cement plaster of mix 1:5 (1 cement : 5 fine sand)
1118
-
-
Code No. 13.9.2
cement plaster 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement - 20mm cement plaster
35
-
-
Code No. 13.9.2A
15 mm cement plaster on the rough side of single or half brick wall of mix 1:5 (1 cement : 5 fine sand)
706
-
-
Code No. 13.46.1
Finishing walls with acrylic smooth exterior paint of required shade - New work (two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm
2307
-
-
Code No. 13.50.1
Applying priming coat - with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood)
88
-
-
Code No. 13.50.3
Applying priming coat: - with ready mixed Red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works.
50
-
-
Code No. 13.61.1
Painting with synthetic enamel paint of approved brand anf manufacutre to give an even shade - two or more coats on new work.
138
-
-
Code No. 17.13.2
Providing and fixing white vitreous china water closet squatting pan (Indian type) - Orissa pattern W.C.pan of size 580x440mm.
6
-
-
Code No. 17.14.1
Extra for using coloured W.C.pan instead of white W.C.pan - Orissa pattern W.C.pan 580x440mm
6
-
-
Code No. 18.9.21
Providing and fixing ASTM pipes including all ASTM plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes & fitting with one step ASTM solvent cement and the cost of cutting chases and making good the same including testing of jointscomplete (Concealed work including cutting chases and making good the walls etc.) - 20 mm nominal outer dia pipes
42
-
-
Code No. 18.17.1A
Providing and fixing gun metal gate valve with C.I.wheel of approved quality (screwed end) - 20 mm nominal bore
12
-
-
Code No. 18.18.2
Providing and fixing ball valve (brass) of approved quality , high or low pressure , with plastic floats complete - 20mm nominal bore
6
-
-
Code No. 18.48A
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI: 12701 marked , with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank - Circular Tank
6000
-
-
Code No. 20.2.1
Boring , providing and installing bored cast -in-situ reinforced cement concrete piles of grade M-25 of specified diameterand length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring , with bentonite solution and temporary casing of appropriate lenghth for setting out and removal of same and the lenghth of the pile to be embedded in the pile cap etc. all complete , including removal of excavated earth with all lifts and leads (length of pile for payment shall be measured upto bottom of pile cap) - 300 mm dia piles.
244
-
-
Code No. 21.3.1
Providing and fixing glazing in aluminium door, window , ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings ( cost of aluminium snap beading shall be paid in basic item) - with float glass panes of 4.0 mm thickness
46
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements