Airports Authority Of India Tender
View complete overview of Puducherry AAI Tender
Airports Authority Of India - AAI Tender
Coronavirus COVID 19
Eprocure
Opening Date13 Jan 2019
Closing Date9 Jan 2019
Tender Amount₹ 40,56,368
Costs
EMD
₹ 81,127Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2018_AAI_19360_1Bid Award Id
ViewTender No
AAI/PDY/ENGG(C)/Solar Plant/18-19Tender Authority
Airports Authority Of India ViewPurchaser Address
-Website
http://https://www.aai.aero/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
65
-
-
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50m outside the periphery of the area cleared.
12141
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
a) 1:5:10 (1 cement : 5 coarse Sand : 10 graded stone aggregate 40 mm nominal size)
14
-
-
Centering and shuttering including strutting, propping etc. and removal of form for :
a) Foundations, footings, bases of columns, etc. for mass concrete.
38
-
-
Centering and shuttering including strutting, propping etc. and removal of form for :
b) Lintels, beams, plinth beams, girders, bressumers and cantilevers.
32
-
-
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
a)Thermo-Mechanically Treated bars of grade Fe-500D or more.
2000
-
-
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix,including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.(Note :- Cement content considered in this item is @ 330 kg/cum.Excess/less cement used as per design mix is payable/recoverable separately).
a) All works upto plinth level
13
-
-
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in
a) Cement mortar 1:6 (1 cement : 6 coarse Sand)
11
-
-
52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
100
-
-
12 mm cement plaster of mix
a) 1:6 (1 cement: 6 coarse sand)
40
-
-
Finishing walls with water proofing cement paint of required shade :
a) New work (Two or more coats applied @ 3.84 kg/10 sqm)
40
-
-
Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
570
-
-
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. a) With material conforming to Grade-II (size range 53 mm to 0.075 mm) having CBR Value-25
57
-
-
Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.
57
-
-
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
1310
-
-
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
a) Hot finished welded type tubes
1675
-
-
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : i) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately).
a) Anodised aluminium (Anodised transparent or dyed to required shade according to IS 1868, Minimum anodic coating of grade AC 15)
46
-
-
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item):
a) With float glass panes of 5.50 mm thickness.
6
-
-
Providing and laying Ceramic glazed floor tiles of size 300x300mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
12
-
-
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :
a) W.C. pan with ISI marked white solid plastic seat and lid
1
-
-
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
i) Internal work - Exposed on wall
a) 15 mm nominal outer dia Pipes
10
-
-
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
i) Internal work - Exposed on wall
a) 25 mm nominal outer dia Pipes
15
-
-
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
a) Circular tank
500
-
-
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.
a) 15 mm nominal bore
1
-
-
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.
a) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5.
1
-
-
Providing and fixing PUF panels on roof made out with 0.4 mm thick Pre coated Profile steel sheets at outer side and 0.25 mm thick Pre coated plain sheet at inner side of PUF and total thickness of roof panel shall be 30 mm.
121
-
-
Providing and fixing wall cladding with PUF panels made out with 0.4 mm thick Pre-coated plain sheets at outer and inner side of PUF in MS tubular section. In base 1.6mm thick GI channel of size 50x62x30mm and top 1.2mm thick GI channel of size 40x62x40mm to be fixed in wall panel. Total thickness of wall panel shall be 50 mm. The panels are joined together by tongue and groove method and placed in the vertical direction.
184
-
-
Providing and fixing PUF door on PUF panel walls made out with 0.4 mm thick Pre-coated plain sheets at outer and inner side of PUF. Total thickness of door panel shall be 30 mm. The rate includes necessary door fittings etc complete as per the direction of Engineer-in-charge.
6
-
-
Electrical Works
-
-
-
Sub Head:1I Internal Electrification
-
-
-
Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
-
-
-
Group C
13
-
-
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
-
-
-
Group C
11
-
-
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
6
-
-
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
7
-
-
Supplying and fixing following size/ modules, PVC box alongwith modular base & cover plate for modular switches in recess etc as required
-
-
-
3 Module
3
-
-
6 Module
2
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
-
-
-
2 X 1.5 sq.mm + 1 X 1.5 sq.mm earth wire
100
-
-
2 X 2.5 sq.mm + 1 X 2.5 sq.mm earth wire
100
-
-
2 X 4 sq.mm + 1 X 4 sq.mm earth wire
100
-
-
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
-
-
-
20 mm
25
-
-
25 mm
25
-
-
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel / PVC conduit as required.
-
-
-
a) 3 x 1.5 sq. mm
25
-
-
b) 3 x 2.5 sq. mm
25
-
-
c) 3 x 4 sq. mm
25
-
-
Supply and fixing rotary stepped type electronic fan regulator (1 module) on the existing modular plate switch box including connections but excluding modular plate etc. as required.
3
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required
-
-
-
5/6 Amps switch
5
-
-
15/16 Amps switch
5
-
-
3 pin 5/6 Amps socket outlet
5
-
-
6 pin 15/16 Amps socket outlet
5
-
-
Telephone socket outlet
2
-
-
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted,inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required •
-
-
-
4 way double door DB
1
-
-
Supplying and fixing following rating, 415 volts, 10 KA Four pole MCB, C curve in the existing MCB DB complete with connections, testing and commissioning etc., as required
-
-
-
63A FP MCB
1
-
-
Supplying and fixing of 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
12
-
-
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out letand complete with connections, testing and commissioning etc. as required.
4
-
-
Supplying and fixing following rating, 415 volts, Four pole RCCB, C curve in the existing MCB DB complete with connections, testing and commissioning etc., as required 63A FP RCCB, 300mA
1
-
-
Supplying and Installation following rating, 230 volts, exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
Upto 450 mm sweep
1
-
-
Supplying, Installation, testing and commissioning of 20 W Surface/Wall Mounted LED Batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver, suitable for operation on single phase,230 Volts, 50HZ, AC power supply etc complete as required.
16
-
-
Supplying,Installation, testing and commissioning of 5 star rated energy efficient ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
3
-
-
Supply of 45W LED Street light luminaire comprising of die-cast aluminium housing powder coated along with toghened glass with IP 65 protection with in-built electronic driver complete i/c having 95 lm / watt and 50,000 burning hours with all accessories, all prewired suitable for operation on 230 V 50 Hz Ac supply etc complete as required
4
-
-
Installation, testing and commissioning of prewired LED street light integral luminaire complete with all accessories directly on the building/wall including providing & fixing street light bracket of suitable size made out of "B" class GI pipe along with GI clamp/bolt/nuts etc., as required
4
-
-
Fire Alarm Works
-
-
-
Supply, Installation, Testing & Commissioning single loop, networkable,multi-protocol, analogue addressable fire alarm control panel Display:6x40 character (240x64 pixels) blue liquid, Indicators: Fire, Fault, Disablement, Test, BuzzerMuted, Delayed Mode, Sounders Silenced,Sounders Disabled and Power. Also dedicated fault LEDs for System Fault, Sounder Fault, Supply Fault and Earth Fault. 40, 80 or 160 LED fire zone crystal display with backlight illumination indicators optional. Programming Keys: 12 button alpha numeric keypad inc cancel and return keys plus 4 navigationkeys and an OK key.The ITC shall include the smoke detectors, GSM Dialer, Manual call points and Hooter cum Strobe etc as complete as required.
1
-
-
Supply of GSM dialer, GSM based Voice and SMS dialer, Micro-controller based, 2 Voice Messages, Separate Intrusion & Fire Message, 15 Telephone Numbers for Each Message, 20 Second Recording Time for Each Message, Alarm SMS with Alarm Type, Time and Date Information, System Status SMS for Arm & Disarm, Separate SMS for Tamper & Wrong code, Non-volatile Memory, GSM Signal Strength display. Can be integrated with Intruder Alarm Panels, Fire Alarm Panels, DVR's, Video Door Phones, Access Control Systems and more etc as required.
1
-
-
Supply of UL Listed Addressable type smoke Detector complete with all accessories like base, base box, etc. to be installed under/above false ceiling, roof and concealed space, etc. interconnecting to loop cable complete in all respects as required by the standard specifications.
4
-
-
Supply of UL Listed Addressable type Manual Call Point (break glass type) complete with Input Module, push button, enclosed in box with provision for cable or conduit coupling etc.complete in all respects as required by the standard specifications. The unit to be painted fire red outside, white inside and written 'In case of fire break glass'.
2
-
-
Supply of UL listed Hooter cum Strobe with Base plate complete in all respects as required by the standard specifications.
2
-
-
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required.
2C X1.5 SQ mm
150
-
-
AC Works
-
-
-
Supply, Installing, Testing and Commissioing of Inverter Split Type , 2.0 TR Airconditioners ( of 5 star rating consisting of HI-Wall split 2.0 Ton indoor unit, condensing unit (out door unit) with fully hermetically sealed compressor suitable for operation on 1 phase, 230V±10%, 50HZ, AC power supply . The supply of unit shall include the copper pipings, power cables for interconnecting between the indoor unit and outdoor unit as per standard manufacturer design (ie.., upto 3 mtrs) including the drain pipies & out door stand, first charge of refrigerant R 410 A/ R32 etc as required (Make: As per the approved makes). The rate quoted shall be inclusive of transportation charges upto Puducherry Airport.
a) Drain PVC pipe [11/2" dia or as per OEM's standard size]
b) Insulated copper pipe --- Liquid Line [1/4" dia as per OEM's standard size]
c) Insulated copper pipe --- Suction Line [1/2" dia as per OEM's standard size]
d) 3 core x 2.5 Sqmm PVC insulated copper wire.[ or as per OEM's standard size]
4
-
-
Supply & fixing of Extra length of the following, suitable for 2.0 TR Airconditioner (inter connections suitable for item No.1)
a) Drain PVC pipe [1 1/2" dia or as per OEM's standard size]
b) insultated copper pipe - liquid line [1/4" dia or as per OEM's standard size]
c) Insulated copper pipe - Suction [1/2" dia or as per OEM's standard size]
d) d) 3 core x 2.5 Sqmm PVC insulated copper wire[ or as per OEM's standard size] The rates quoted shall be inclusive of transportation charges upto Puducherry Airport.
20
-
-
Supply, installation, testing and commissining of wall mounting type 5 KVA Capacity, single phase, automatic line voltage stabilzer, suitable for operation on 170 volts AC input, 200 volts to 240 volts AC output, single phase, 50Hz AC power supply with built in time delay, high voltage cutoff, and low voltage cut off at 145 volts and input/output/ trip indications and suitable for aplication of 2.0 Ton Air conditioning unit etc, as required.
4
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements