Works Department Tender

Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.

Works Department Tender

Works
Electrical and Electronics
Eprocure
Opening Date18 Jun 2024
Closing Date2 Jul 2024
Tender Amount₹ 1,22,56,249 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Double Pole Belting Channel 75X40X 4.8mm., 7.14KG/Mtr., each channel length 1.66 Mtr., 4 no's channel required =( 7.14x1.66x4)

94.82

-

-

... More
50x50x6mm.GI Bracing Angle, 4.5Kg./mtr., each angle length 2.671 mtr., 4 nos angle required = (4.5x2.671x4)

96.16

-

-

... More
Danger Plate, 2 no's.

4

-

-

... More
Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 2 no's = (2x0.59x0.510)

1.2

-

-

... More
H.T. Stay clamp, 50x8 mm. flat, 3.14Kg/Mtr., 0.551 Mtr. Length, 2 no's qty. required ( 1 Pair)

4

-

-

... More
H.T. Stay set (Complete )

4

-

-

... More
H.T. Stay Insulator Type-C

4

-

-

... More
7/10 SWG Stay Wire 15kg /stay

60

-

-

... More
Gi Pipe Earthing 40mm. 3 Mtr. Long

2

-

-

... More
50x6mm GI Flat for earthing, 2.36kg/mtr., (2.5 mtr. For mesh formation and 2.5 mtr. For raising)= 5x2.36

23.6

-

-

... More
GI barbed wire anticlimbing device 3 Kg. Per support, 2 no's qty. required =(2x3kg)

12

-

-

... More
Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 8 no's = (8x0.59x0.510)

4.81

-

-

... More
11 KV pin insulator polymer

6

-

-

... More
H W fitting(B&S) 70KN, 3Bolt

12

-

-

... More
Disc insulator (B&S) 70 KN polymer

12

-

-

... More
PG Clamp for 100 sq.mm AAA conductor

12

-

-

... More
GI Nut , Bolt & Washer of different sizes (12.261 Kg each DP without AB Switch)

24.52

-

-

... More
Black Paint

2

-

-

... More
Yellow Colour Paint for Background

4

-

-

... More
Fixing of complete 11KV line Complete stay set includes 1) Turn Buckle Assembly 2) Stay Rod & Stay plate 3) Stay Insulator 4) Stay Wire. 5)Stay clamps with Nuts & bolts BA will do the excvation including excvation, supply of 0.5Cum cement concrete foundation 1:2:4 size ( 500mmx500mmx800mm) using 20mm BHG metal with all labour and material as per TPCODL Drawing & Standard.

4

-

-

... More
Concreting ratio 1:1.5:3 (500mmX500mmX1800mm) = 0.45Cu.mtr

1.8

-

-

... More
Couping ratio 1:1.5:3 with dimension (500X500X450)= 0.1125 Cu mtr

0.45

-

-

... More
Construction Earthing chamber including installation of earthing pipe.Making earthing chamber including excavation , soil treatment with bentonide powder , calculation of earth resistance, including Installation of 3Mtr GI Pipe 40mm/50mm including welding of GI flat around pipe .

2

-

-

... More
WPB (GI) Pole 160x152 (11Mtr. Long, 30.44KG/Mtr.)

2

-

-

... More
Top Channel 100X50X6mm, 9.56 KG/Mtr., each channel length 3 mtr., 2 no's channel required =( 2x9.56x3)

57.36

-

-

... More
Fish Plate 50x6 mm., 2.36 kg/Mtr., each 0.280 mtr. length, 6 no's required = (6x2.36x0.280)

3.96

-

-

... More
AB switch Mounting Channel 75X40X4.8mm, 7.14KG/Mtr, each channel length 3 Mtr., 2 no's channel required =( 7.14x3x2)

42.84

-

-

... More
AB Switch Side Support Channel 100X50X6mm,9.56 KG/Mtr., each channel length 0.35 mtr., 2 no's channel required =( 9.56x2x0.35)

6.69

-

-

... More
Channel Support for down Pipe 75X40X 4.8mm., 7.14KG/Mtr., each channel length 0.8 Mtr., 1 no's channel required =( 7.14x0.8x1)

5.71

-

-

... More
Double Pole Belting Channel 75X40X 4.8mm., 7.14KG/Mtr., each channel length 3.0 Mtr., 4 no's channel required =( 7.14x3x4)

85.68

-

-

... More
50x50x6mm.GI Bracing Angle, 4.5Kg./mtr., each angle length 3.512 mtr., 4 nos angle required = (4.5x3.512x4)

63.22

-

-

... More
Danger Plate, 2 no's.

2

-

-

... More
Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 2 no's = (2x0.59x0.510)

0.6

-

-

... More
H.T. Stay clamp, 50x8 mm. flat, 3.14Kg/Mtr., 0.551 Mtr. Length, 2 no's qty. required ( 1 Pair)

2

-

-

... More
H.T. Stay set (Complete )

2

-

-

... More
H.T. Stay Insulator Type-C

2

-

-

... More
7/10 SWG Stay Wire 15kg /stay

30

-

-

... More
Gi Pipe Earthing 40mm. 3 Mtr. Long

2

-

-

... More
50x6mm GI Flat for earthing, 2.36kg/mtr., (12.5 Mtr. For L.A, 3 Mtr for AB Switch Body, 2.5 mtr. For mesh formation and 2.5 mtr. For raising)= 20.5x2.36

48.38

-

-

... More
GI barbed wire anticlimbing device 3 Kg. Per support, 2 no's qty. required =(2x3kg)

6

-

-

... More
Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 8 no's = (8x0.59x0.510)

2.41

-

-

... More
Lightning Arrester(12KV,10KA) (Station Class,class-2)

3

-

-

... More
AB Switch (11KV,400A.3pole,50Hz)

1

-

-

... More
11 KV pin insulator polymer

3

-

-

... More
H W fitting(B&S) 70KN, 3Bolt

6

-

-

... More
Disc insulator (B&S) 70 KN polymer

6

-

-

... More
PG Clamp for 100 sq.mm AAA conductor

6

-

-

... More
GI Nut , Bolt & Washer of different sizes (13.718 Kg each DP with AB Switch)

13.72

-

-

... More
Black Paint

1

-

-

... More
Yellow Colour Paint for Background

2

-

-

... More
Fixing of complete 11KV line Complete stay set includes 1) Turn Buckle Assembly 2) Stay Rod & Stay plate 3) Stay Insulator 4) Stay Wire. 5)Stay clamps with Nuts & bolts BA will do the excvation including excvation, supply of 0.5Cum cement concrete foundation 1:2:4 size ( 500mmx500mmx800mm) using 20mm BHG metal with all labour and material as per TPCODL Drawing & Standard.

2

-

-

... More
Concreting ratio 1:1.5:3 (500mmX500mmX1800mm) = 0.45Cu.mtr

0.9

-

-

... More
Couping ratio 1:1.5:3 with dimension ( 500X500X450)= 0.1125 Cu mtr

0.23

-

-

... More
Construction Earthing chamber including installation of earthing pipe.Making earthing chamber including excavation , soil treatment with bentonide powder , calculation of earth resistance, including Installation of 3Mtr GI Pipe 40mm/50mm including welding of GI flat around pipe .

2

-

-

... More
WPB (GI) Pole 160x152 (11Mtr. Long, 30.44KG/Mtr.)

4

-

-

... More
Straight Cross Arm 100X50X6mm, 9.56 KG/Mtr., each channel length 1.2 mtr., 2 no's channel required =( 2x9.56x1.2)

91.78

-

-

... More
Fish Plate 50x6 mm., 2.36 kg/Mtr., each 0.280 mtr. length, 8 no's required = (8x2.36x0.280)

21.15

-

-

... More
Straight Cross Arm 100X50X6mm, 9.56 KG/Mtr., each channel length 0.306 mtr., 2 no's channel required =(2x9.56x0.306)

23.4

-

-

... More
Danger Plate, 1 no's.

4

-

-

... More
Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 1 no's = (1x0.59x0.510)

1.2

-

-

... More
GI barbed wire anticlimbing device 3 Kg. Per support

12

-

-

... More
Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 4 no's = (4x0.59x0.510)

4.81

-

-

... More
11 KV pin insulator polymer

12

-

-

... More
H W fitting(B&S) 70KN, 3Bolt

24

-

-

... More
Disc insulator (B&S) 70 KN polymer

24

-

-

... More
Earthing of Support ( Coil Type )

4

-

-

... More
No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing

1.05

-

-

... More
PG Clamp for 100 sq.mm AAA conductor

24

-

-

... More
GI Nut , Bolt & Washer of different sizes (3.55 Kg each Cut Pole)

14.2

-

-

... More
Black Paint

2

-

-

... More
Yellow Colour Paint for Background

8

-

-

... More
Concreting ratio 1:1.5:3 (500mmX500mmX1800mm) = 0.45Cu.mtr

1.8

-

-

... More
Couping ratio 1:1.5:3 with dimension ( 500X500X450)= 0.1125 Cu mtr

0.45

-

-

... More
WPB (GI) Pole 160x152 (11Mtr. Long, 30.44KG/Mtr.)

1

-

-

... More
Straight Cross Arm 100X50X6mm, 9.56 KG/Mtr., each channel length 1.2 mtr., 4 no's channel required =( 4x9.56x1.2)

45.89

-

-

... More
Fish Plate 50x6 mm., 2.36 kg/Mtr., each 0.280 mtr. length, 16 no's required = (16x2.36x0.280)

10.57

-

-

... More
Straight Cross Arm 100X50X6mm, 9.56 KG/Mtr., each channel length 0.306 mtr., 4 no's channel required =( 4x9.56x0.306)

11.7

-

-

... More
Danger Plate, 1 no's.

1

-

-

... More
Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 1 no's = (1x0.59x0.510)

0.3

-

-

... More
GI barbed wire anticlimbing device 3 Kg. Per support

3

-

-

... More
Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 4 no's = (4x0.59x0.510)

1.2

-

-

... More
11 KV pin insulator polymer

4

-

-

... More
H W fitting(B&S) 70KN, 3Bolt

6

-

-

... More
Disc insulator (B&S) 70 KN polymer

6

-

-

... More
Earthing of Support ( Coil Type )

1

-

-

... More
No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing

0.26

-

-

... More
PG Clamp for 100 sq.mm AAA conductor

6

-

-

... More
H.T. Stay clamp, 50x8 mm. flat, 3.14Kg/Mtr., 0.551 Mtr. Length, 2 no's qty. required ( 1 Pair)

2

-

-

... More
H.T. Stay set (Complete )

2

-

-

... More
H.T. Stay Insulator Type-C

2

-

-

... More
7/10 SWG Stay Wire 15kg /stay

30

-

-

... More
GI Nut , Bolt & Washer of different sizes (7.433 Kg each Cut Pole)

7.43

-

-

... More
Black Paint

0.5

-

-

... More
Yellow Colour Paint for Background

2

-

-

... More
Fixing of complete 11KV line Complete stay set includes 1) Turn Buckle Assembly 2) Stay Rod & Stay plate 3) Stay Insulator 4) Stay Wire. 5)Stay clamps with Nuts & bolts BA will do the excvation including excvation, supply of 0.5Cum cement concrete foundation 1:2:4 size ( 500mmx500mmx800mm) using 20mm BHG metal with all labour and material as per TPCODL Drawing & Standard.

2

-

-

... More
Concreting ratio 1:1.5:3 (500mmX500mmX1800mm) = 0.45Cu.mtr

0.45

-

-

... More
Couping ratio 1:1.5:3 with dimension ( 500X500X450)= 0.1125 Cu mtr

0.11

-

-

... More
WPB (GI) Pole 160x152 (11Mtr. Long, 30.44KG/Mtr.)

15

-

-

... More
11 KV V cross Arm (10.2 K.g. each )

15

-

-

... More
Top bracket 100x50X6 mm GI channel (2kg each)

15

-

-

... More
Danger Plate, 1 no's. for each pole

15

-

-

... More
Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 1 no's = (1x0.59x0.510)

4.51

-

-

... More
GI barbed wire anticlimbing device 3 Kg. Per support

45

-

-

... More
Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 4 no's = (4x0.59x0.510)

18.05

-

-

... More
11 KV pin insulator polymer, 3 Nos. required for each support

45

-

-

... More
Earthing of Support ( Coil Type )

15

-

-

... More
No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing

3.93

-

-

... More
GI Nut , Bolt & Washer of different sizes (1.45 Kg/ Pin Point)

21.75

-

-

... More
100 mm2 AAAC

2935.5

-

-

... More
Black Paint

15

-

-

... More
Yellow Colour Paint for Background

30

-

-

... More
Concreting ratio 1:1.5:3 (500mmX500mmX1800mm) = 0.45Cu.mtr

6.75

-

-

... More
Couping ratio 1:1.5:3 with dimension ( 500X500X450)= 0.1125 Cu mtr

1.69

-

-

... More
Inspection Fee of Over Head Line (HT) - Rs. 375 up to 1 km

1

-

-

... More
Inspection Fee of Over Head Line (HT) - Rs. 225/ Additional Km

1

-

-

... More
WPB (GI) Pole 160x152 (11Mtr. Long, 30.44KG/Mtr.)

8

-

-

... More
9 Mtr. long 300 Kg. PSC Pole (For Raising of LT ABC)

4

-

-

... More
Pole clamp for EYE hook for (XLPE Aerial bunched Cable)

8

-

-

... More
EYE hook for XLPE Aerial bunched Cable

8

-

-

... More
Dead End Clamp suitable for messenger XLPE Aerial bunched Cable

8

-

-

... More
Top Channel GI 100 X 50 X 6 MM (3000 mm long) (9.56Kg./Mtr, 2 No's.) (Each 2x3.000x9.56= 57.36 Kg)

229.44

-

-

... More
Fish Plate 50x6 mm., 2.36 kg/Mtr., each 0.280 mtr. length, 6 no's required = (6x2.36x0.280)

15.86

-

-

... More
M.U Channel GI 75x40x4.8 mm (3000 mm long)(7.14Kg./Mtr., 2 No's.) (Each 2x3.000x7.14= 42.84 Kg)

171.36

-

-

... More
AB Switch Mounting Channel 75x40x4.8 mm GI Channel (3000 mm long)(7.14Kg./Mtr., 2 No's.) (Each 2x3.000x7.14= 42.84 Kg)

171.36

-

-

... More
AB Switch Side Support Channel 100X50X6mm,9.56 KG/Mtr., each channel length 0.35 mtr., 2 no's channel required =( 9.56x2x0.35)

26.77

-

-

... More
Channel Support for down Pipe 75X40X 4.8mm., 7.14KG/Mtr., each channel length 0.8 Mtr., 1 no's channel required =( 7.14x0.8x1)

22.85

-

-

... More
HG/ DO Fuse Mounting Channel 75x40x4.8 mm GI Channel (3000 mm long)(7.14Kg./Mtr., 2 No's.) (Each 2x3.000x7.14= 42.84 Kg)

171.36

-

-

... More
Cantilever Support Channel 75x40x4.8 mm GI Channel (810 mm long,2 No's.) (7.14Kg./Mtr., 2 No's.) (Each 2x0.810x7.14= 11.57 Kg)

46.27

-

-

... More
Cantilever Support Angle 50 X 50 X 6MM GI (1282 mm long) (4.5Kg./Mtr, 2 No's.) (Each 2x1.282x4.5= 11.54Kg)

46.15

-

-

... More
Transformer Base GI Channel 100 X 50 X 6 MM (3000 mm long) (9.56Kg./Mtr, 2 No's.) (Each 2x3.000x9.56= 57.36 Kg)

229.44

-

-

... More
Transformer Base Support GI Channel 100 X 50 X 6 MM (515 mm long) (9.56Kg./Mtr, 2 No's) (Each 2x0.515x9.56= 9.85Kg)

39.39

-

-

... More
Transformer Belting Angle 50 X 50 X 6MM GI (3000 mm long)(4.5Kg./Mtr, 2 No's) (Each 2x3.0x4.5 Kg)

108

-

-

... More
Transformer Belting Support Angle 50 X 50 X 6MM GI (580 mm long)(4.5Kg./Mtr,2 No's) (Each 2x0.580x4.5= Kg)

20.88

-

-

... More
LTDB Mounting Angle 50 X 50 X 6MM GI (1000 mm long)(4.5Kg./Mtr, 2 No's) (Each 2x1x4.5 Kg)

36

-

-

... More
50x6mm GI Flat for earthing, 2.36kg/mtr., (2.5x7 mtr. For mesh formation, 12 Mtr. For LA and 2.5 mtr. For raising, 11 mtr for AB switch, 2.8 mtr for HG Fuse, 5x2 mtr. for DTR Nutral, (1.3+4.5) mtr. For DTR Body, 0.500 mtr for LTDB & AB Switch operating handle, 3 mtr. for Fencing) ( Each 65.6x 2.36= 154.81 Kg)

619.26

-

-

... More
LT Distribution Box with MCCB, Aluminium Busbar of 2 Bay with kit kat fuse for 100 KVA S/S

4

-

-

... More
55mm2 All Alloy Aluminum Conductor (AAAC) - PVC Insulated (50 Mtr. Each Dtr.)

200

-

-

... More
4 Cx 150 mm2 LT XLPE Cable(Armoured) - FOR 100 KVA Trf.

60

-

-

... More
AB Switch(11KV,200A.3pole,50Hz)

4

-

-

... More
H.G.Fuse( 11KV.200A.3Pole)

4

-

-

... More
PG Clamp for 55 sq.mm AAA conductor

24

-

-

... More
Disc insulator (B&S)70 KN polymer

12

-

-

... More
H W fitting (B&S)70KN(3bolted)

12

-

-

... More
Lightning Arrester(12KV,10KA) Station Class 2

12

-

-

... More
11KV pin insulator polymer

12

-

-

... More
HT stay set complete

8

-

-

... More
HT stay Clamp (1.9Kg/pair)

8

-

-

... More
HT stay insulator TYPE-C

8

-

-

... More
7/10 SWG GI stay wire, Grade -2 (15Kg./ Set)

120

-

-

... More
40 mm Nominal bore GI pipe (medium gauge) earthing device with 3 mtr .Long

28

-

-

... More
GI Nuts & Bolts of Assorted size (25 Kg/ DSS DP)

100

-

-

... More
GI Barbed wire/Anticlimbing device (3Kg /Pole)

24

-

-

... More
Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 8 no's = (8x0.59x0.510)

9.63

-

-

... More
Danger plate 11kv

8

-

-

... More
Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 2 no's = (2x0.59x0.510)

2.41

-

-

... More
Name plate

4

-

-

... More
Painting of Yellow Colour Paint for Background

8

-

-

... More
Painting of Black Colour Paint for Numbering

4

-

-

... More
Concreting ratio 1:1:5:3(500mm x500mmx1800mm) =0.45Cu.mtr (For WPB Pole)

3.6

-

-

... More
Couping ratio 1:1:5:3 with dimension (500 x500x450)= 0.1125 Cu mtr

0.9

-

-

... More
Fixing of stay with 0.5Cum cement concrete foundation 1:3:6 size( 900mmx600mmx900mm) using 40mm BHG metal with all labor and material except stay set ,stay wire, stay insulator .

8

-

-

... More
Construction of Earthing chamber including installation of earthing pipe , Making earthing chamber including excavation, soil treatment with bentonide powder , calculation of earth resistance including installation of 3 Mtr Gi Pipe 40mm/50mm including welding of GI flat aroung pipe

28

-

-

... More
Laying of 1 C 400mm^2 LT XLPE Cable

60

-

-

... More
Supply and erection of GI fencing with Gate.

60

-

-

... More
Concreting ratio 1:1:5:3(500mm x500mmx1500mm) =0.375Cu.mtr

1.5

-

-

... More
WPB (GI) Pole 160x152 (11Mtr. Long, 30.44KG/Mtr.)

2

-

-

... More
9 Mtr. long 300 Kg. PSC Pole (For Raising of LT ABC)

1

-

-

... More
Pole clamp for EYE hook for (XLPE Aerial bunched Cable)

2

-

-

... More
EYE hook for XLPE Aerial bunched Cable

2

-

-

... More
Dead End Clamp suitable for messenger XLPE Aerial bunched Cable

2

-

-

... More
Top Channel GI 100 X 50 X 6 MM (3000 mm long) (9.56Kg./Mtr, 2 No's.) (Each 2x3.000x9.56= 57.36 Kg)

57.36

-

-

... More
Fish Plate 50x6 mm., 2.36 kg/Mtr., each 0.280 mtr. length, 6 no's required = (6x2.36x0.280)

3.96

-

-

... More
Double Pole Belting Channel 75X40X 4.8mm., 7.14KG/Mtr., each channel length 3.0 Mtr., 2 no's channel required =( 7.14x3x2)

42.84

-

-

... More
50x50x6mm.GI Bracing Angle, 4.5Kg./mtr., each angle length 3.512 mtr., 2 nos angle required = (4.5x3.512x2)

31.61

-

-

... More
M.U Channel GI 75x40x4.8 mm (3000 mm long)(7.14Kg./Mtr., 2 No's.) (Each 2x3.000x7.14= 42.84 Kg)

42.84

-

-

... More
AB Switch Mounting Channel 75x40x4.8 mm GI Channel (3000 mm long)(7.14Kg./Mtr., 2 No's.) (Each 2x3.000x7.14= 42.84 Kg)

42.84

-

-

... More
AB Switch Side Support Channel 100X50X6mm,9.56 KG/Mtr., each channel length 0.35 mtr., 2 no's channel required =( 9.56x2x0.35)

6.69

-

-

... More
Channel Support for down Pipe 75X40X 4.8mm., 7.14KG/Mtr., each channel length 0.8 Mtr., 1 no's channel required =( 7.14x0.8x1)

5.71

-

-

... More
HG/ DO Fuse Mounting Channel 75x40x4.8 mm GI Channel (3000 mm long)(7.14Kg./Mtr., 2 No's.) (Each 2x3.000x7.14= 39.98 Kg)

42.84

-

-

... More
Cantilever Support Channel 75x40x4.8 mm GI Channel (810 mm long,2 No's.) (7.14Kg./Mtr., 2 No's.) (Each 2x0.810x7.14= 11.57 Kg)

11.57

-

-

... More
Cantilever Support Angle 50 X 50 X 6MM GI (1282 mm long) (4.5Kg./Mtr, 2 No's.) (Each 2x1.282x4.5= 11.54Kg)

11.54

-

-

... More
50x6mm GI Flat for earthing, 2.36kg/mtr., (2.5x7 mtr. For mesh formation, 12 Mtr. For LA and 2.5 mtr. For raising, 11 mtr for AB switch, 2.8 mtr for HG Fuse, 5x2 mtr. for DTR Nutral, (1.3+4.5) mtr. For DTR Body, 0.500 mtr for LTDB & AB Switch operating handle, 3 mtr. for Fencing) ( Each 65.6x 2.36= 154.81 Kg)

154.82

-

-

... More
LT Distribution Box with MCCB, Aluminium Busbar for 3 Bay with kit kat fuse for 250 KVA S/S

1

-

-

... More
55mm2 All Alloy Aluminum Conductor (AAAC) - PVC Insulated (50 Mtr. Each Dtr.)

50

-

-

... More
1 Cx 400 mm2 LT XLPE Cable(Un-Armoured)

120

-

-

... More
AB Switch(11KV,200A.3pole,50Hz)

1

-

-

... More
H.G.Fuse( 11KV.200A.3Pole)

1

-

-

... More
PG Clamp for 55 sq.mm AAA conductor

6

-

-

... More
Disc insulator (B&S)70 KN polymer

3

-

-

... More
H W fitting (B&S)70KN(3bolted)

3

-

-

... More
Lightning Arrester(12KV,10KA) Station Class 2

3

-

-

... More
11KV pin insulator polymer

3

-

-

... More
HT stay set complete

2

-

-

... More
HT stay Clamp (1.9Kg/pair)

2

-

-

... More
HT stay insulator TYPE-C

2

-

-

... More
7/10 SWG GI stay wire, Grade -2 (15Kg./ Set)

30

-

-

... More
40 mm Nominal bore GI pipe (medium gauge) earthing device with 3 mtr .Long

7

-

-

... More
GI Nuts & Bolts of Assorted size (25 Kg/ DSS DP)

25

-

-

... More
GI Barbed wire/Anticlimbing device (3Kg /Pole)

6

-

-

... More
Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 8 no's = (8x0.59x0.510)

2.41

-

-

... More
Danger plate 11kv

2

-

-

... More
Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 2 no's = (2x0.59x0.510)

0.6

-

-

... More
Name plate

1

-

-

... More
Painting of Yellow Colour Paint for Background

2

-

-

... More
Painting of Black Colour Paint for Numbering

1

-

-

... More
Concreting ratio 1:1:5:3(500mm x500mmx1800mm) =0.45Cu.mtr (For WPB Pole)

0.9

-

-

... More
Couping ratio 1:1:5:3 with dimension (500 x500x450)= 0.1125 Cu mtr

0.23

-

-

... More
Fixing of stay with 0.5Cum cement concrete foundation 1:3:6 size( 900mmx600mmx900mm) using 40mm BHG metal with all labor and material except stay set ,stay wire, stay insulator .

2

-

-

... More
Construction of Earthing chamber including installation of earthing pipe , Making earthing chamber including excavation, soil treatment with bentonide powder , calculation of earth resistance including installation of 3 Mtr Gi Pipe 40mm/50mm including welding of GI flat aroung pipe

7

-

-

... More
LTDB Plinth

1

-

-

... More
DTR Plinth

1

-

-

... More
Laying of 1 C 400mm^2 LT XLPE Cable

120

-

-

... More
Supply and erection of GI fencing with Gate.

20

-

-

... More
Concreting ratio 1:1:5:3(500mm x500mmx1500mm) =0.375Cu.mtr

0.38

-

-

... More
WPB (GI) Pole 160x152 (11Mtr. Long, 30.44KG/Mtr.)

2

-

-

... More
9 Mtr. long 300 Kg. PSC Pole (For Raising of LT ABC)

1

-

-

... More
Pole clamp for EYE hook for (XLPE Aerial bunched Cable)

2

-

-

... More
EYE hook for XLPE Aerial bunched Cable

2

-

-

... More
Dead End Clamp suitable for messenger XLPE Aerial bunched Cable

2

-

-

... More
Top Channel GI 100 X 50 X 6 MM (3000 mm long) (9.56Kg./Mtr, 2 No's.) (Each 2x3.000x9.56= 57.36 Kg)

57.36

-

-

... More
Fish Plate 50x6 mm., 2.36 kg/Mtr., each 0.280 mtr. length, 6 no's required = (6x2.36x0.280)

3.96

-

-

... More
Double Pole Belting Channel 75X40X 4.8mm., 7.14KG/Mtr., each channel length 3.0 Mtr., 2 no's channel required =( 7.14x3x2)

42.84

-

-

... More
50x50x6mm.GI Bracing Angle, 4.5Kg./mtr., each angle length 3.512 mtr., 2 nos angle required = (4.5x3.512x2)

31.61

-

-

... More
M.U Channel GI 75x40x4.8 mm (3000 mm long)(7.14Kg./Mtr., 2 No's.) (Each 2x3.000x7.14= 42.84 Kg)

42.84

-

-

... More
AB Switch Mounting Channel 75x40x4.8 mm GI Channel (3000 mm long)(7.14Kg./Mtr., 2 No's.) (Each 2x3.000x7.14= 42.84 Kg)

42.84

-

-

... More
AB Switch Side Support Channel 100X50X6mm,9.56 KG/Mtr., each channel length 0.35 mtr., 2 no's channel required =( 9.56x2x0.35)

6.69

-

-

... More
Channel Support for down Pipe 75X40X 4.8mm., 7.14KG/Mtr., each channel length 0.8 Mtr., 1 no's channel required =( 7.14x0.8x1)

5.71

-

-

... More
HG/ DO Fuse Mounting Channel 75x40x4.8 mm GI Channel (3000 mm long)(7.14Kg./Mtr., 2 No's.) (Each 2x3.000x7.14= 39.98 Kg)

42.84

-

-

... More
Cantilever Support Channel 75x40x4.8 mm GI Channel (810 mm long,2 No's.) (7.14Kg./Mtr., 2 No's.) (Each 2x0.810x7.14= 11.57 Kg)

11.57

-

-

... More
Cantilever Support Angle 50 X 50 X 6MM GI (1282 mm long) (4.5Kg./Mtr, 2 No's.) (Each 2x1.282x4.5= 11.54Kg)

11.54

-

-

... More
50x6mm GI Flat for earthing, 2.36kg/mtr., (2.5x7 mtr. For mesh formation, 12 Mtr. For LA and 2.5 mtr. For raising, 11 mtr for AB switch, 2.8 mtr for HG Fuse, 5x2 mtr. for DTR Nutral, (1.3+4.5) mtr. For DTR Body, 0.500 mtr for LTDB & AB Switch operating handle, 3 mtr. for Fencing) ( Each 65.6x 2.36= 154.81 Kg)

154.82

-

-

... More
LT Distribution Box with MCCB, Aluminium Busbar for 4 Bay with kit kat fuse for 500 KVA S/S

1

-

-

... More
55mm2 All Alloy Aluminum Conductor (AAAC) - PVC Insulated (50 Mtr. Each Dtr.)

50

-

-

... More
1 Cx 400 mm2 LT XLPE Cable(Un-Armoured)

180

-

-

... More
AB Switch(11KV,200A.3pole,50Hz)

1

-

-

... More
H.G.Fuse( 11KV.200A.3Pole)

1

-

-

... More
PG Clamp for 55 sq.mm AAA conductor

6

-

-

... More
Disc insulator (B&S)70 KN polymer

3

-

-

... More
H W fitting (B&S)70KN(3bolted)

3

-

-

... More
Lightning Arrester(12KV,10KA) Station Class 2

3

-

-

... More
11KV pin insulator polymer

3

-

-

... More
HT stay set complete

2

-

-

... More
HT stay Clamp (1.9Kg/pair)

2

-

-

... More
HT stay insulator TYPE-C

2

-

-

... More
7/10 SWG GI stay wire, Grade -2 (15Kg./ Set)

30

-

-

... More
40 mm Nominal bore GI pipe (medium gauge) earthing device with 3 mtr .Long

7

-

-

... More
GI Nuts & Bolts of Assorted size (25 Kg/ DSS DP)

25

-

-

... More
GI Barbed wire/Anticlimbing device (3Kg /Pole)

6

-

-

... More
Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 8 no's = (8x0.59x0.510)

2.41

-

-

... More
Danger plate 11kv

2

-

-

... More
Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 2 no's = (2x0.59x0.510)

0.6

-

-

... More
Name plate

1

-

-

... More
Painting of Yellow Colour Paint for Background

2

-

-

... More
Painting of Black Colour Paint for Numbering

1

-

-

... More
Concreting ratio 1:1:5:3(500mm x500mmx1800mm) =0.45Cu.mtr (For WPB Pole)

0.9

-

-

... More
Couping ratio 1:1:5:3 with dimension (500 x500x450)= 0.1125 Cu mtr

0.23

-

-

... More
Fixing of stay with 0.5Cum cement concrete foundation 1:3:6 size( 900mmx600mmx900mm) using 40mm BHG metal with all labor and material except stay set ,stay wire, stay insulator .

2

-

-

... More
Construction of Earthing chamber including installation of earthing pipe , Making earthing chamber including excavation, soil treatment with bentonide powder , calculation of earth resistance including installation of 3 Mtr Gi Pipe 40mm/50mm including welding of GI flat aroung pipe

7

-

-

... More
LTDB Plinth

1

-

-

... More
DTR Plinth

1

-

-

... More
Laying of 1 C 400mm^2 LT XLPE Cable

180

-

-

... More
Supply and erection of GI fencing with Gate.

20

-

-

... More
Concreting ratio 1:1:5:3(500mm x500mmx1500mm) =0.375Cu.mtr

0.38

-

-

... More
GI H Pole (13Mtr. Long, 30.44KG/Mtr.)

4

-

-

... More
Top Channel 100X50X6mm, 9.56 KG/Mtr., each channel length 4.3 mtr., 8 no's channel required =( 8x9.56x4.3)

328.86

-

-

... More
Fish Plate 50x6 mm., 2.36 kg/Mtr., each 0.280 mtr. length, 24 no's required = (24x2.36x0.280)

15.86

-

-

... More
Isolator Support Cahnnel 75X40X 4.8mm., 7.14KG/Mtr., each channel length 4.3 Mtr., 2 no's channel required =( 2x7.14x4.3)/ Isolator

61.4

-

-

... More
Double Pole Belting Channel 75X40X 4.8mm., 7.14KG/Mtr., each channel length 4.3 Mtr., 8 no's channel required =( 8x7.14x4.3)

245.62

-

-

... More
50x50x6mm.GI Bracing Angle, 4.5Kg./mtr., each angle length 4.927 mtr., 8 nos angle required = (8*4.5*4.927)

177.37

-

-

... More
Isolator Operating Down Pipe Support Cahnnel 75X40X 4.8mm., 7.14KG/Mtr., each channel length 0.8 Mtr., 1 no channel required =( 1x7.14x0.8)/ Isolator

5.71

-

-

... More
Down Pipe Diagonal Support Angle, 4.5Kg./mtr., each angle length 0.388mtr., 1 no angle required = (1*4.5*0.388)/ Isolator

1.75

-

-

... More
Down Pipe Base Support Angle, 4.5Kg./mtr., each angle length 0.34mtr., 1 no angle required = (1*4.5*0.340)/ Isolator

1.53

-

-

... More
Isolator Support Side Cahnnel 100X50X6mm, 9.56 KG/Mtr., each channel length 0.5 mtr., 2 no's channel required =( 2x9.56x0.5)/ Isolator

9.56

-

-

... More
Danger Plate, 2 no's.

2

-

-

... More
Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 2 no's = (2x0.59x0.510)

0.6

-

-

... More
Gi Pipe Earthing 40mm. 3 Mtr. Long

3

-

-

... More
50x6mm GI Flat for earthing, 2.36kg/mtr., (15 Mtr. For L.A, 4 Mtr for Isolator Body, 2.5 mtr. For mesh formation and 5 mtr. For raising)

62.54

-

-

... More
GI barbed wire anticlimbing device 3 Kg. Per support, 4 no's qty. required =(4x3kg)

12

-

-

... More
Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 16 no's = (16x0.59x0.510)

4.81

-

-

... More
Lightning Arrester(30KV,10KA) (Station Class,class-2)

3

-

-

... More
33 KV 1250 AMP Double break (Turn & twist center rotating) isolator without earth switch with Pl(Polymer)

1

-

-

... More
33KV pin insulator polymer

6

-

-

... More
H W fitting(B&S)90KN,4 Bolt

18

-

-

... More
Disc insulator (B&S) 90 KN polymer

18

-

-

... More
PG Clamp for 232 sq.mm AAA conductor

24

-

-

... More
232 sq.mm AAA conductor

30.9

-

-

... More
GI Nut , Bolt & Washer of different sizes

45

-

-

... More
Black Paint

1

-

-

... More
Yellow Colour Paint for Background

2

-

-

... More
Concreting ratio 1:1.5:3 (500mmX500mmX2200mm) = 0.55Cu.mtr

2.2

-

-

... More
Couping ratio 1:1.5:3 with dimension (500X500X450)= 0.1125 Cu mtr

0.45

-

-

... More
Construction Earthing chamber including installation of earthing pipe.Making earthing chamber including excavation , soil treatment with bentonide powder , calculation of earth resistance, including Installation of 3Mtr GI Pipe 40mm/50mm including welding of GI flat around pipe .

3

-

-

... More
GI H Pole (13Mtr. Long, 30.44KG/Mtr.)

4

-

-

... More
Top Channel 100X50X6mm, 9.56 KG/Mtr., each channel length 3.25 mtr., 2 no's channel required =( 2x9.56x3.25)

124.28

-

-

... More
Fish Plate 50x6 mm., 2.36 kg/Mtr., each 0.280 mtr. length, 6 no's required = (6x2.36x0.280)

7.93

-

-

... More
Double Pole Belting Channel 75X40X 4.8mm., 7.14KG/Mtr., each channel length 1.96 Mtr., 5 no's channel required =( 5x7.14x1.96)

139.94

-

-

... More
50x50x6mm.GI Bracing Angle, 4.5Kg./mtr., each angle length 3.432 mtr., 4 nos angle required = (4*4.5*3.432)

123.55

-

-

... More
Danger Plate, 2 no's.

4

-

-

... More
Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 2 no's = (2x0.59x0.510)

1.2

-

-

... More
H.T. Stay clamp, 50x8 mm. flat, 3.14Kg/Mtr., 0.511 Mtr. Length, 2 no's qty. required ( 1 Pair)

4

-

-

... More
H.T. Stay set (Complete )

4

-

-

... More
H.T. Stay Insulator Type-C (2 No's.)

8

-

-

... More
7/8 SWG Stay Wire 15kg /stay

60

-

-

... More
Gi Pipe Earthing 40mm. 3 Mtr. Long

2

-

-

... More
50x6mm GI Flat for earthing, 2.36kg/mtr., (2.5 mtr. For mesh formation and 2.5 mtr. For raising)= 5x2.36

23.6

-

-

... More
GI barbed wire anticlimbing device 3 Kg. Per support

12

-

-

... More
Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 8 no's = (8x0.59x0.510)

4.81

-

-

... More
33KV pin insulator polymer

6

-

-

... More
H W fitting(B&S) 90KN,4 Bolt

12

-

-

... More
Disc insulator (B&S) 90 KN polymer

12

-

-

... More
PG Clamp for 232 sq.mm AAA conductor

12

-

-

... More
GI Nut , Bolt & Washer of different sizes (12.261 Kg each DP without Isolator)

24.52

-

-

... More
Black Paint

2

-

-

... More
Yellow Colour Paint for Background

4

-

-

... More
Fixing of complete 11KV line Complete stay set includes 1) Turn Buckle Assembly 2) Stay Rod & Stay plate 3) Stay Insulator 4) Stay Wire. 5)Stay clamps with Nuts & bolts BA will do the excvation including excvation, supply of 0.5Cum cement concrete foundation 1:2:4 size ( 500mmx500mmx800mm) using 20mm BHG metal with all labour and material as per TPCODL Drawing & Standard.

4

-

-

... More
Concreting ratio 1:1.5:3 (500mmX500mmX1800mm) = 0.45Cu.mtr

2.2

-

-

... More
Couping ratio 1:1.5:3 with dimension (500X500X450)= 0.1125 Cu mtr

0.45

-

-

... More
Construction Earthing chamber including installation of earthing pipe.Making earthing chamber including excavation , soil treatment with bentonide powder , calculation of earth resistance, including Installation of 3Mtr GI Pipe 40mm/50mm including welding of GI flat around pipe .

2

-

-

... More
13 Mtr. Long H-Pole(GI)

1

-

-

... More
Straight Cross Arm Channel 100 x 50 x 6 mm, 9.56 KG/mtr, each channel length 1.7 Mtr., 4 No's of Channel = (4x 9.56x1.7)

65.01

-

-

... More
Fish Plate 50x6 mm., 2.36 kg/Mtr., each 0.280 mtr. length, 16 no's required = (16x2.36x0.280)

10.57

-

-

... More
Straight Cross Arm Top Channel 100 x 50 x 6 mm, 9.56 KG/mtr, each channel length 0.306 Mtr., 4 No's of Channel = (4x 9.56x0.306)

11.7

-

-

... More
Danger Plate, 1 no's.

1

-

-

... More
Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 1 no's = (1x0.59x0.510)

0.3

-

-

... More
GI barbed wire anticlimbing device 3 Kg. Per support

3

-

-

... More
Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 4 no's = (4x0.59x0.510)

1.2

-

-

... More
33KV pin insulator polymer (4 No's each 90 Deg. Cut point)

4

-

-

... More
H W fitting(B&S)90KN,4 Bolt

6

-

-

... More
Disc insulator (B&S)90 KN polymer

6

-

-

... More
Earthing of Support ( Coil Type )

1

-

-

... More
No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing

0.26

-

-

... More
PG Clamp for 232 sq.mm AAA conductor

6

-

-

... More
H.T. Stay clamp, 50x8 mm. flat, 3.14Kg/Mtr., 0.511 Mtr. Length, 2 no's qty. required ( 1 Pair)

1

-

-

... More
H.T. Stay set (Complete )

1

-

-

... More
H.T. Stay Insulator Type-C (2 No's.)

1

-

-

... More
7/8 SWG Stay Wire 15kg /stay

15

-

-

... More
GI Nut , Bolt & Washer of different sizes (11.31 Kg each 90 deg. Cut point)

11.31

-

-

... More
Black Paint

1

-

-

... More
Yellow Colour Paint for Background

2

-

-

... More
Fixing of 33KV line Complete stay set includes 1) Turn Buckle Assembly 2) Stay Rod & Stay plate 3) Stay Insulator 4) Stay Wire. 5)Stay clamps with Nuts & bolts, including excvation, supply of 0.5Cum cement concrete foundation 1:2:4 size (500mmx500mmx800mm) using 20mm BHG metal with all labour and material (Excavation of earth will be done of size 500X500X1500 mm.)

1

-

-

... More
Concreting ratio 1:1.5:3 (500mmX500mmX2200mm) = 0.55Cu.mtr

0.55

-

-

... More
Couping ratio 1:1.5:3 with dimension ( 500X500X450)= 0.1125 Cu mtr

0.11

-

-

... More
13 Mtr. Long H-Pole(GI)

5

-

-

... More
33 KV V cross Arm (GI) 22Kg each

5

-

-

... More
Top bracket 100x50x6mm GI channel ( 300mm each)

5

-

-

... More
Danger Plate, 1 no's.

5

-

-

... More
Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 1 no's = (1x0.59x0.510)

1.5

-

-

... More
GI barbed wire anticlimbing device 3 Kg. Per support

15

-

-

... More
Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 4 no's = (4x0.59x0.510)

6.02

-

-

... More
33KV pin insulator polymer

15

-

-

... More
Earthing of Support ( Coil Type )

5

-

-

... More
No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing

1.31

-

-

... More
GI Nut , Bolt & Washer of different sizes (1.45 Kg/ Pin Point)

7.25

-

-

... More
232 sq.mm AAA conductor

927

-

-

... More
Black Paint

5

-

-

... More
Yellow Colour Paint for Background

10

-

-

... More
Concreting ratio 1:1.5:3 (500mmX500mmX2200mm) = 0.55Cu.mtr

2.75

-

-

... More
Couping ratio 1:1.5:3 with dimension ( 500X500X450)= 0.1125 Cu mtr

0.56

-

-

... More
Supply of 33kV, 3Core, 400sqmm Aluminium, XLPE insulation UG Cable with spare (SC rating of cable in kA- 37.7kA and SC rating of Armour in kA-20kA)

300

-

-

... More
Supply of Outdoor termination kits Heat Shrinkable type suitable for 33kV, 3Core, 400sqmm, HT UG Cable kits

4

-

-

... More
Supply of materials for High Density Polyethelene (HDPE) pipe 160mm diameter, PE 80- PN8 for laying of 33kV UG cable

300

-

-

... More
Laying, Commissioning & Testing of 33kV, 3Core, 1Run, 400sqmm, XLPE insulation (extruted type) UG cable with spare by open trench method.

300

-

-

... More
Erection of Outdoor termination kits Heat Shrinkable type suitable for 33kV, 3Core, 400sqmm, HT UG cable kits

4

-

-

... More
Laying of 160mm dia PE 80-PN8, HDPE pipe inside open trench.

300

-

-

... More
Earth work excavation of soil

126

-

-

... More
Earth work excavation of hard rock

54

-

-

... More
Back filling with excavated soil outside and above the trench

180

-

-

... More
Damage of asphalt/tar road and other utilities and reconstructing to bring to its original shape after laying of cable in open trench (1mtr. width)

150

-

-

... More
Supply and erection of GI Pipe of dia. 150mm, Class-B (8Mtr.)

32

-

-

... More
Renovation of Cable loop Chamber

12

-

-

... More
Supply and Erection of Cable Route Marker along the cable route at an interval of 30mtrs with civil works

5

-

-

... More
Inspection Fee of UG Line (HT) - Rs. 3000/ km.

1

-

-

... More
Inspection Fee of UG Line (HT) - Rs. 1500/ Additional Km

1

-

-

... More
Supply of 11kV, 3Core, 400sqmm, XLPE insulation armoured UG cable (SC rating of cable in kA- 37.7kA and SC rating of Armour in kA- 15kA)

180

-

-

... More
Supply of Outdoor termination kits Heat Shrinkable type suitable for 11kV, 3Core, 400 sqmm, HT UG cable for 3Core (Set)

4

-

-

... More
Supply of HDPE PE 80-PN8 pipe of 160mm diameter (for 400sqmm HT cable laying)

180

-

-

... More
Laying, Commissioning, Testing of 11kV, 3core, 400sqmm, aluminium, XLPE insulation armoured (extruded type) UG cable by open trench method.

180

-

-

... More
Erection of Outdoor termination kits Heat Shrinkable type suitable for 11kV, 3Core, 400sqmm, aluminium UG cable kits for 3core (set)

4

-

-

... More
Laying of 160mm dia PE 80-PN8, HDPE pipe inside open trench.

180

-

-

... More
Earth work excavation of soil

63

-

-

... More
Earth work excavation of hard rock

27

-

-

... More
Back filling with excavated soil outside and above the trench

90

-

-

... More
Damage of asphalt/tar road and other utilities and reconstructing to bring to its original shape after laying of cable in open trench (1mtr. width)

90

-

-

... More
Supply and erection of GI Pipe of dia. 150mm, Class-B (8Mtr.)

32

-

-

... More
Supply and Erection of Cable Route Marker along the cable route at an interval of 30mtrs with civil works

3

-

-

... More
9 Mtr. long 300 Kg. PSC Pole

56

-

-

... More
LT Stay set Complete

18

-

-

... More
7/12 SWG GI stay wire, Grade -2

216

-

-

... More
LT stay Clamp ( 1.40Kg/pair)

18

-

-

... More
LT Stay insulator

18

-

-

... More
Pole clamp for EYE hook for (XLPE Aerial bunched Cable)

56

-

-

... More
EYE hook for XLPE Aerial bunched Cable

18

-

-

... More
Dead End Clamp suitable for messenger XLPE Aerial bunched Cable

18

-

-

... More
Suspension Clamp with EYE hook for ABC

35

-

-

... More
4C×95 mm² (P)+1C×95 mm²(M)+1CX16 mm²(Street Light) (LT AB Cable)

2310

-

-

... More
Insulated piercing connector.Type-A-main 50 to 150 sq.mm & Tap-50 to 150 sq.mm

44

-

-

... More
Insulated piercing connector.Type-C-main 16 to 95 sq.mm & Tap-1.5 to 16 sq.mm

11

-

-

... More
Pipe Earthing (each 5th pole to earth)

11

-

-

... More
Coil Earthing

45

-

-

... More
No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing

14.67

-

-

... More
Danger plate (LT)

56

-

-

... More
Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 1 no's = (1x0.59x0.510)

16.85

-

-

... More
GI barbed wire anticlimbing device 3 Kg. Per support

168

-

-

... More
Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 4 no's = (4x0.59x0.510)

67.4

-

-

... More
GI Nut , Bolt & Washer of different sizes (0.5 Kg/ Pole)

28

-

-

... More
Black Paint

56

-

-

... More
Yellow Colour Paint for Background

112

-

-

... More
Fixing of LT Complete stay set includes 1) Turn Buckle Assembly 2) Stay Rod & Stay plate 3) Stay Insulator 4) Stay Wire. 5)Stay clamps with Nuts & bolts, including excvation, supply of 0.5Cum cement concrete foundation 1:2:4 size (500mmx500mmx800mm) using 20mm BHG metal with all labour and material (Excavation of earth will be done of size 500X500X1500 mm.)

18

-

-

... More
Concreting ratio 1:1.5:3 (500mmX500mmX1500mm) = 0.375Cu.mtr

21

-

-

... More
Construction Earthing chamber including installation of earthing pipe.Making earthing chamber including excavation , soil treatment with bentonide powder , calculation of earth resistance, including Installation of 3Mtr GI Pipe 40mm/50mm including welding of GI flat around pipe .

11

-

-

... More
CABLE 2X4 SQMM SERVICE CABLE PVC

27000

-

-

... More
4C X 25sq. mm. Armoured Aluminium Cable - XLPE Insulated

70

-

-

... More
Insulated piercing connector.Type-C-main 16 to 95 sq.mm & Tap-1.5 to 16 sq.mm - For LT AB Cable

8

-

-

... More
GI Nut , Bolt & Washer

0.5

-

-

... More
Three Phase Service Connection Cable Dismantling (Upto 30 Mtr.)

2

-

-

... More
Meter Installation- Single Phase

30

-

-

... More
Meter Removal- Single Phase

30

-

-

... More
Single Phase Meter Accuracy Test at Side-SP

30

-

-

... More
Punching of Protocols for field activities

30

-

-

... More
Instalation of 2C*4 sq mm armoured-sp

30

-

-

... More
Service cable removal of any size used for SP

30

-

-

... More
9mtr long PSC pole

22

-

-

... More
11mtr RS joist pole (with DP)

23

-

-

... More
Existing 11/0.4KV, Three Phase DSS(100VA)

4

-

-

... More
Existing 11/0.4KV, Three Phase DSS(250KVA

1

-

-

... More
Existing 11/0.4KV, Three Phase DSS(500KVA)

1

-

-

... More
11KV V Cross Arm

15

-

-

... More
11KV GI Pin

45

-

-

... More
Dismatling of channel

420

-

-

... More
Dismantling of Disc insulator

9

-

-

... More
100mm2 AAAC

2550

-

-

... More
Dismatling of AB cable

550

-

-

... More
ITC of 100KVA Transformer

4

-

-

... More
ITC of 250KVA Transformer

1

-

-

... More
ITC of 500KVA Transformer

1

-

-

... More
Labour charges loading, transportation, unloading and staking at a proper place in safe position/site store. N.B. (while shifting or relocation of existing infrastructure ,Deduction of Salvage value of 8% of the original cost of such infrastructure is to be considered in the estimate amounting Rs 83,258.00)

9

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.