Works Department Tender

Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.

Works Department - EICCL Tender

Works
Civil And Construction
Road Construction
Electrical and Electronics
Electrical Works
Eprocure
Opening Date12 Aug 2024
Closing Date22 Aug 2024
Tender Amount₹ 42,36,297 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Double Pole Belting Channel 75X40X 4.8mm., 7.14KG/Mtr., each channel length 1.66 Mtr., 4 no's channel required =( 7.14x1.66x4)

47.41

4341

91.58

... More
50x50x6mm.GI Bracing Angle, 4.5Kg./mtr., each angle length 2.671 mtr., 4 nos angle required = (4.5x2.671x4)

48.08

4402

91.58

... More
Danger Plate, 2 no's.

2

250

125.32

... More
Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 2 no's = (2x0.59x0.510)

0.6

70

117.49

... More
H.T. Stay clamp, 50x8 mm. flat, 3.14Kg/Mtr., 0.551 Mtr. Length, 2 no's qty. required ( 1 Pair)

2

391

195.81

... More
H.T. Stay set (Complete )

2

3289

1644.83

... More
H.T. Stay Insulator Type-C

2

156

78.33

... More
7/10 SWG Stay Wire 15kg /stay

30

3524

117.49

... More
Gi Pipe Earthing 40mm. 3 Mtr. Long

1

1644

1644.83

... More
50x6mm GI Flat for earthing, 2.36kg/mtr., (2.5 mtr. For mesh formation and 2.5 mtr. For raising)= 5x2.36

11.8

1386

117.49

... More
GI barbed wire anticlimbing device 3 Kg. Per support, 2 no's qty. required =(2x3kg)

6

751

125.32

... More
Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 8 no's = (8x0.59x0.510)

2.41

282

117.49

... More
11 KV pin insulator polymer

3

939

313.3

... More
H W fitting(B&S) 70KN, 3Bolt

6

3289

548.28

... More
Disc insulator (B&S) 70 KN polymer

6

10808

1801.48

... More
PG Clamp for 80 sq.mm AAA conductor

6

4981

830.25

... More
GI Nut , Bolt & Washer of different sizes (12.261 Kg each DP without AB Switch)

12.26

1498

122.19

... More
Black Paint

1

344

344.63

... More
Yellow Colour Paint for Background

2

520

260.28

... More
Fixing of complete 11KV line Complete stay set includes 1) Turn Buckle Assembly 2) Stay Rod & Stay plate 3) Stay Insulator 4) Stay Wire. 5)Stay clamps with Nuts & bolts BA will do the excvation including excvation, supply of 0.5Cum cement concrete foundation 1:2:4 size ( 500mmx500mmx800mm) using 20mm BHG metal with all labour and material as per TPCODL Drawing & Standard.

2

4545

2272.5

... More
Concreting ratio 1:1.5:3 (500mmX500mmX1800mm) = 0.45Cu.mtr

0.9

5908

6565

... More
Couping ratio 1:1.5:3 with dimension (500X500X450)= 0.1125 Cu mtr

0.23

1477

6565

... More
Construction Earthing chamber including installation of earthing pipe.Making earthing chamber including excavation , soil treatment with bentonide powder , calculation of earth resistance, including Installation of 3Mtr GI Pipe 40mm/50mm including welding of GI flat around pipe .

1

3737

3737

... More
DP With AB Switch WPB (GI) Pole 160x152 (11Mtr. Long, 30.44KG/Mtr.)

2

68516

34258.46

... More
Top Channel 100X50X6mm, 9.56 KG/Mtr., each channel length 3 mtr., 2 no's channel required =( 2x9.56x3)

57.36

5253

91.58

... More
Fish Plate 50x6 mm., 2.36 kg/Mtr., each 0.280 mtr. length, 6 no's required = (6x2.36x0.280)

3.96

465

117.49

... More
AB switch Mounting Channel 75X40X4.8mm, 7.14KG/Mtr, each channel length 3 Mtr., 2 no's channel required =( 7.14x3x2)

42.84

3923

91.58

... More
AB Switch Side Support Channel 100X50X6mm,9.56 KG/Mtr., each channel length 0.35 mtr., 2 no's channel required =( 9.56x2x0.35)

6.69

612

91.58

... More
Channel Support for down Pipe 75X40X 4.8mm., 7.14KG/Mtr., each channel length 0.8 Mtr., 1 no's channel required =( 7.14x0.8x1)

5.71

523

91.58

... More
Double Pole Belting Channel 75X40X 4.8mm., 7.14KG/Mtr., each channel length 3.0 Mtr., 4 no's channel required =( 7.14x3x4)

85.68

7846

91.58

... More
50x50x6mm.GI Bracing Angle, 4.5Kg./mtr., each angle length 3.512 mtr., 4 nos angle required = (4.5x3.512x4)

63.22

5789

91.58

... More
Danger Plate, 2 no's.

2

250

125.32

... More
Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 2 no's = (2x0.59x0.510)

0.6

70

117.49

... More
H.T. Stay clamp, 50x8 mm. flat, 3.14Kg/Mtr., 0.551 Mtr. Length, 2 no's qty. required ( 1 Pair)

2

391

195.81

... More
H.T. Stay set (Complete )

2

3289

1644.83

... More
H.T. Stay Insulator Type-C

2

156

78.33

... More
7/10 SWG Stay Wire 15kg /stay

30

3524

117.49

... More
Gi Pipe Earthing 40mm. 3 Mtr. Long

2

3289

1644.83

... More
50x6mm GI Flat for earthing, 2.36kg/mtr., (12.5 Mtr. For L.A, 3 Mtr for AB Switch Body, 2.5 mtr. For mesh formation and 2.5 mtr. For raising)= 20.5x2.36

48.38

5684

117.49

... More
GI barbed wire anticlimbing device 3 Kg. Per support, 2 no's qty. required =(2x3kg)

6

751

125.32

... More
Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 8 no's = (8x0.59x0.510)

2.41

282

117.49

... More
Lightning Arrester(12KV,10KA) (Station Class,class-2)

3

16683

5561.08

... More
AB Switch (11KV,400A.3pole,50Hz)

1

18563

18563.03

... More
11 KV pin insulator polymer

3

939

313.3

... More
H W fitting(B&S) 70KN, 3Bolt

6

3289

548.28

... More
Disc insulator (B&S) 70 KN polymer

6

10808

1801.48

... More
PG Clamp for 80 sq.mm AAA conductor

6

4981

830.25

... More
GI Nut , Bolt & Washer of different sizes (13.718 Kg each DP with AB Switch)

13.72

1676

122.19

... More
Black Paint

1

344

344.63

... More
Yellow Colour Paint for Background

2

520

260.28

... More
Fixing of complete 11KV line Complete stay set includes 1) Turn Buckle Assembly 2) Stay Rod & Stay plate 3) Stay Insulator 4) Stay Wire. 5)Stay clamps with Nuts & bolts BA will do the excvation including excvation, supply of 0.5Cum cement concrete foundation 1:2:4 size ( 500mmx500mmx800mm) using 20mm BHG metal with all labour and material as per TPCODL Drawing & Standard.

2

4545

2272.5

... More
Concreting ratio 1:1.5:3 (500mmX500mmX1800mm) = 0.45Cu.mtr

0.9

5908

6565

... More
Couping ratio 1:1.5:3 with dimension ( 500X500X450)= 0.1125 Cu mtr

0.23

1477

6565

... More
Construction Earthing chamber including installation of earthing pipe.Making earthing chamber including excavation , soil treatment with bentonide powder , calculation of earth resistance, including Installation of 3Mtr GI Pipe 40mm/50mm including welding of GI flat around pipe .

2

7474

3737

... More
11 KV Cut Point with 90 Degree Angle (8nos.) WPB (GI) Pole 160x152 (11Mtr. Long, 30.44KG/Mtr.)

8

274067

34258.46

... More
Straight Cross Arm 100X50X6mm, 9.56 KG/Mtr., each channel length 1.2 mtr., 4 no's channel required =( 4x9.56x1.2)

367.1

33619

91.58

... More
Fish Plate 50x6 mm., 2.36 kg/Mtr., each 0.280 mtr. length, 16 no's required = (16x2.36x0.280)

84.58

9937

117.49

... More
Straight Cross Arm 100X50X6mm, 9.56 KG/Mtr., each channel length 0.306 mtr., 4 no's channel required =( 4x9.56x0.306)

93.61

8572

91.58

... More
Danger Plate, 1 no's.

8

1002

125.32

... More
Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 1 no's = (1x0.59x0.510)

2.41

282

117.49

... More
GI barbed wire anticlimbing device 3 Kg. Per support

24

3007

125.32

... More
Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 4 no's = (4x0.59x0.510)

9.63

1131

117.49

... More
11 KV pin insulator polymer

32

10025

313.3

... More
H W fitting(B&S) 70KN, 3Bolt

52.5

28784

548.28

... More
Disc insulator (B&S) 70 KN polymer

52.5

94577

1801.48

... More
Earthing of Support ( Coil Type )

8

2080

260.04

... More
No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing

2.1

246

117.49

... More
PG Clamp for 80 sq.mm AAA conductor

52.5

43588

830.25

... More
H.T. Stay clamp, 50x8 mm. flat, 3.14Kg/Mtr., 0.551 Mtr. Length, 2 no's qty. required ( 1 Pair)

16

3132

195.81

... More
H.T. Stay set (Complete )

16

26317

1644.83

... More
H.T. Stay Insulator Type-C

16

1253

78.33

... More
7/10 SWG Stay Wire 15kg /stay

240

28197

117.49

... More
GI Nut , Bolt & Washer of different sizes (7.433 Kg each Cut Pole)

59.46

7265

122.19

... More
Black Paint

4

1378

344.63

... More
Yellow Colour Paint for Background

16

4164

260.28

... More
Fixing of complete 11KV line Complete stay set includes 1) Turn Buckle Assembly 2) Stay Rod & Stay plate 3) Stay Insulator 4) Stay Wire. 5)Stay clamps with Nuts & bolts BA will do the excvation including excvation, supply of 0.5Cum cement concrete foundation 1:2:4 size ( 500mmx500mmx800mm) using 20mm BHG metal with all labour and material as per TPCODL Drawing & Standard.

16

36360

2272.5

... More
Concreting ratio 1:1.5:3 (500mmX500mmX1800mm) = 0.45Cu.mtr

3.6

23634

6565

... More
Couping ratio 1:1.5:3 with dimension ( 500X500X450)= 0.1125 Cu mtr

0.9

5908

6565

... More
11 KV Pin Points With PSC PSC POLE 9 METER LONG 300 KG

45

229027

5089.5

... More
PSC Pole V cross Arm Back Clamp

45

5639

125.32

... More
11 KV V cross Arm (10.2 K.g. each )

45

57099

1268.87

... More
Top bracket 100x50X6 mm GI channel (2kg each)

45

10574

234.98

... More
Danger Plate, 1 no's. for each pole

45

5639

125.32

... More
Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 1 no's = (1x0.59x0.510)

13.5

1586

117.49

... More
GI barbed wire anticlimbing device 3 Kg. Per support

133

16667

125.32

... More
Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 4 no's = (4x0.59x0.510)

54.16

6363

117.49

... More
11 KV pin insulator polymer, 3 Nos. required for each support

133

41668

313.3

... More
Earthing of Support ( Coil Type )

45

11701

260.04

... More
No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing

11.79

1385

117.49

... More
GI Nut , Bolt & Washer of different sizes (1.45 Kg/ Pin Point)

65.25

7972

122.19

... More
55 mm2 AAAC

2.55

119837

46995

... More
80 mm2 AAAC

4.15

279541

67359.5

... More
Crimping type Midspan Compression Joint for 55 sq.mm AAA conductor

6

1933

322.31

... More
Black Paint

45

15508

344.63

... More
Yellow Colour Paint for Background

90

23425

260.28

... More
Concreting ratio 1:1.5:3 (500mmX500mmX1500mm) = 0.375 Cu.mtr

16.87

110751

6565

... More
Shifting & re-construction of 100 KVA SS - 1 No WPB (GI) Pole 160x152 (11Mtr. Long, 30.44KG/Mtr.)

2

68516

34258.45

... More
Top Channel GI 100 X 50 X 6 MM (3000 mm long) (9.56Kg./Mtr, 2 No's.) (Each 2x3.000x9.56= 57.36 Kg)

57.36

5253

91.58

... More
Fish Plate 50x6 mm., 2.36 kg/Mtr., each 0.280 mtr. length, 6 no's required = (6x2.36x0.280)

3.96

465

117.49

... More
AB Switch Mounting Channel 75x40x4.8 mm GI Channel (3000 mm long)(7.14Kg./Mtr., 2 No's.) (Each 2x3.000x7.14= 42.84 Kg)

42.84

3923

91.58

... More
AB Switch Side Support Channel 100X50X6mm,9.56 KG/Mtr., each channel length 0.35 mtr., 2 no's channel required =( 9.56x2x0.35)

6.69

612

91.58

... More
Channel Support for down Pipe 75X40X 4.8mm., 7.14KG/Mtr., each channel length 0.8 Mtr., 1 no's channel required =( 7.14x0.8x1)

5.71

523

91.58

... More
HG/ DO Fuse Mounting Channel 75x40x4.8 mm GI Channel (3000 mm long)(7.14Kg./Mtr., 2 No's.) (Each 2x3.000x7.14= 42.84 Kg)

42.84

3923

91.58

... More
Cantilever Support Channel 75x40x4.8 mm GI Channel (810 mm long,2 No's.) (7.14Kg./Mtr., 2 No's.) (Each 2x0.810x7.14= 11.57 Kg)

11.57

1059

91.58

... More
Cantilever Support Angle 50 X 50 X 6MM GI (1282 mm long) (4.5Kg./Mtr, 2 No's.) (Each 2x1.282x4.5= 11.54Kg)

11.54

1056

91.58

... More
Transformer Base GI Channel 100 X 50 X 6 MM (3000 mm long) (9.56Kg./Mtr, 2 No's.) (Each 2x3.000x9.56= 57.36 Kg)

57.36

5253

91.58

... More
Transformer Base Support GI Channel 100 X 50 X 6 MM (515 mm long) (9.56Kg./Mtr, 2 No's) (Each 2x0.515x9.56= 9.85Kg)

9.85

901

91.58

... More
Transformer Belting Angle 50 X 50 X 6MM GI (3000 mm long)(4.5Kg./Mtr, 2 No's) (Each 2x3.0x4.5 Kg)

27

2472

91.58

... More
Transformer Belting Support Angle 50 X 50 X 6MM GI (580 mm long)(4.5Kg./Mtr,2 No's) (Each 2x0.580x4.5= Kg)

5.22

478

91.58

... More
LTDB Mounting Angle 50 X 50 X 6MM GI (1000 mm long)(4.5Kg./Mtr, 2 No's) (Each 2x1x4.5 Kg)

9

824

91.58

... More
50x6mm GI Flat for earthing, 2.36kg/mtr., (2.5x7 mtr. For mesh formation, 12 Mtr. For LA and 2.5 mtr. For raising, 11 mtr for AB switch, 2.8 mtr for HG Fuse, 5x2 mtr. for DTR Nutral, (1.3+4.5) mtr. For DTR Body, 0.500 mtr for LTDB & AB Switch operating handle, 3 mtr. for Fencing) ( Each 65.6x 2.36= 154.81 Kg)

154.82

18189

117.49

... More
55mm2 All Alloy Aluminum Conductor (AAAC) - PVC Insulated (50 Mtr. Each Dtr.)

50

3328

66.56

... More
4 Cx 150 mm2 LT XLPE Cable(Armoured) - FOR 100 KVA Trf.

15

14893

992.93

... More
AB Switch(11KV,200A.3pole,50Hz)

1

11513

11513.77

... More
H.G.Fuse( 11KV.200A.3Pole)

1

9586

9586.98

... More
PG Clamp for 55 sq.mm AAA conductor

6

4511

751.92

... More
Disc insulator (B&S)70 KN polymer

3

5404

1801.47

... More
H W fitting (B&S)70KN(3bolted)

3

1644

548.27

... More
Lightning Arrester(12KV,10KA) Station Class 2

3

16683

5561.07

... More
11KV pin insulator polymer

3

939

313.3

... More
HT stay set complete

2

3289

1644.82

... More
HT stay Clamp (1.9Kg/pair)

2

391

195.81

... More
HT stay insulator TYPE-C

2

156

78.32

... More
7/10 SWG GI stay wire, Grade -2 (15Kg./ Set)

30

3524

117.49

... More
40 mm Nominal bore GI pipe (medium gauge) earthing device with 3 mtr .Long

7

11513

1644.83

... More
GI Nuts & Bolts of Assorted size (25 Kg/ DSS DP)

25

3054

122.19

... More
GI Barbed wire/Anticlimbing device (3Kg /Pole)

6

751

125.32

... More
Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 8 no's = (8x0.59x0.510)

2.41

282

117.49

... More
Danger plate 11kv

2

250

125.32

... More
Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 2 no's = (2x0.59x0.510)

0.6

70

117.49

... More
Name plate

1

125

125.32

... More
Structure Numbering and Marking Yellow Colour Paint for Background

2

520

260.28

... More
Black Colour Paint for numbering

1

344

344.63

... More
Concreting ratio 1:1.5:3 (500mmX500mmX1800mm) = 0.450Cu.mtr (For WPB Pole)

0.9

5908

6565

... More
Couping ratio 1:1.5:3 (500mmX500mmX450mm) = 0.113Cu.mtr

0.23

1483

6565

... More
Fixing of stay set with 0.5Cum cement concrete foundation 1:3:6 size ( 900mmx600mmx900mm) using 40mm BHG metal with all labor and material except stay set , stay wire , stay insulator .

2

4545

2272.5

... More
Construction Earthing chamber including installation of earthing pipe.Making earthing chamber including excavation , soil treatment with bentonide powder , calculation of earth resistance, including Installation of 3Mtr GI Pipe 40mm/50mm including welding of GI flat around pipe .

7

26159

3737

... More
Laying of 4 Cx 150 mm2 LT XLPE Cable

15

1090

72.72

... More
Supply and Erection of GI Fencing with Gate

15

54540

3636

... More
Shifting & re construction of 25 KVA SS- 2 nos, WPB (GI) Pole 160x152 (11Mtr. Long, 30.44KG/Mtr.)

4

137033

34258.46

... More
Top Channel GI 100 X 50 X 6 MM (3000 mm long) (9.56Kg./Mtr, 2 No's.) (Each 2x3.000x9.56= 57.36 Kg)

114.72

10506

91.58

... More
Fish Plate 50x6 mm., 2.36 kg/Mtr., each 0.280 mtr. length, 6 no's required = (6x2.36x0.280)

7.08

831

117.49

... More
AB Switch Mounting Channel 75x40x4.8 mm GI Channel (3000 mm long)(7.14Kg./Mtr., 2 No's.) (Each 2x3.000x7.14= 42.84 Kg)

85.68

7846

91.58

... More
AB Switch Side Support Channel 100X50X6mm,9.56 KG/Mtr., each channel length 0.35 mtr., 2 no's channel required =( 9.56x2x0.35)

13.38

1225

91.58

... More
Channel Support for down Pipe 75X40X 4.8mm., 7.14KG/Mtr., each channel length 0.8 Mtr., 1 no's channel required =( 7.14x0.8x1)

11.42

1046

91.58

... More
HG/ DO Fuse Mounting Channel 75x40x4.8 mm GI Channel (3000 mm long)(7.14Kg./Mtr., 2 No's.) (Each 2x3.000x7.14= 42.84 Kg)

85.68

7846

91.58

... More
Cantilever Support Channel 75x40x4.8 mm GI Channel (810 mm long,2 No's.) (7.14Kg./Mtr., 2 No's.) (Each 2x0.810x7.14= 11.57 Kg)

23.13

2118

91.58

... More
Cantilever Support Angle 50 X 50 X 6MM GI (1282 mm long) (4.5Kg./Mtr, 2 No's.) (Each 2x1.282x4.5= 11.54Kg)

23.08

2113

91.58

... More
Transformer Base GI Channel 100 X 50 X 6 MM (3000 mm long) (9.56Kg./Mtr, 2 No's.) (Each 2x3.000x9.56= 57.36 Kg)

114.72

10506

91.58

... More
Transformer Base Support GI Channel 100 X 50 X 6 MM (515 mm long) (9.56Kg./Mtr, 2 No's) (Each 2x0.515x9.56= 9.85Kg)

19.69

1803

91.58

... More
Transformer Belting Angle 50 X 50 X 6MM GI (3000 mm long)(4.5Kg./Mtr, 2 No's) (Each 2x3.0x4.5 Kg)

54

4945

91.58

... More
Transformer Belting Support Angle 50 X 50 X 6MM GI (580 mm long)(4.5Kg./Mtr,2 No's) (Each 2x0.580x4.5= Kg)

10.44

956

91.58

... More
LTDB Mounting Angle 50 X 50 X 6MM GI (1000 mm long)(4.5Kg./Mtr, 2 No's) (Each 2x1x4.5 Kg)

18

1648

91.58

... More
50x6mm GI Flat for earthing, 2.36kg/mtr., (2.5x7 mtr. For mesh formation, 12 Mtr. For LA and 2.5 mtr. For raising, 11 mtr for AB switch, 2.8 mtr for HG Fuse, 5x2 mtr. for DTR Nutral, (1.3+4.5) mtr. For DTR Body, 0.500 mtr for LTDB & AB Switch operating handle, 3 mtr. for Fencing) ( Each 65.6x 2.36= 154.81 Kg)

309.63

36377

117.49

... More
55mm2 All Alloy Aluminum Conductor (AAAC) - PVC Insulated (50 Mtr. Each Dtr.)

100

6656

66.56

... More
4 Cx 35 mm2 LT XLPE Cable(Armoured) - FOR 25 KVA Trf.

30

7713

257.12

... More
AB Switch(11KV,200A.3pole,50Hz)

2

23027

11513.78

... More
H.G.Fuse( 11KV.200A.3Pole)

2

19173

9586.98

... More
PG Clamp for 55 sq.mm AAA conductor

12

9023

751.92

... More
Disc insulator (B&S)70 KN polymer

6

10808

1801.48

... More
H W fitting (B&S)70KN(3bolted)

6

3289

548.28

... More
Lightning Arrester(12KV,10KA) Station Class 2

6

33366

5561.08

... More
11KV pin insulator polymer

6

1879

313.3

... More
HT stay set complete

4

6579

1644.83

... More
HT stay Clamp (1.9Kg/pair)

4

783

195.81

... More
HT stay insulator TYPE-C

4

313

78.33

... More
7/10 SWG GI stay wire, Grade -2 (15Kg./ Set)

60

7049

117.49

... More
40 mm Nominal bore GI pipe (medium gauge) earthing device with 3 mtr .Long

14

23027

1644.83

... More
GI Nuts & Bolts of Assorted size (25 Kg/ DSS DP)

50

6109

122.19

... More
GI Barbed wire/Anticlimbing device (3Kg /Pole)

12

1503

125.32

... More
Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 8 no's = (8x0.59x0.510)

4.81

565

117.49

... More
Danger plate 11kv

4

501

125.32

... More
Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 2 no's = (2x0.59x0.510)

1.2

141

117.49

... More
Name plate

2

250

125.32

... More
Structure Numbering and Marking Yellow Colour Paint for Background

4

1041

260.28

... More
Black Colour Paint for numbering

2

689

344.63

... More
Concreting ratio 1:1.5:3 (500mmX500mmX1800mm) = 0.450Cu.mtr (For WPB Pole)

1.8

11817

6565

... More
Couping ratio 1:1.5:3 (500mmX500mmX450mm) = 0.113Cu.mtr

0.45

2967

6565

... More
Fixing of stay set with 0.5Cum cement concrete foundation 1:3:6 size ( 900mmx600mmx900mm) using 40mm BHG metal with all labor and material except stay set , stay wire , stay insulator .

4

9090

2272.5

... More
Construction Earthing chamber including installation of earthing pipe.Making earthing chamber including excavation , soil treatment with bentonide powder , calculation of earth resistance, including Installation of 3Mtr GI Pipe 40mm/50mm including welding of GI flat around pipe .

14

52318

3737

... More
Laying of 4 Cx 35 mm2 LT XLPE Cable

30

1418

47.27

... More
Supply and Erection of GI Fencing with Gate

30

109080

3636

... More
Shifting & re construction of 63 KVA SS-2 Nos WPB (GI) Pole 160x152 (11Mtr. Long, 30.44KG/Mtr.)

4

137033

34258.46

... More
Top Channel GI 100 X 50 X 6 MM (3000 mm long) (9.56Kg./Mtr, 2 No's.) (Each 2x3.000x9.56= 57.36 Kg)

114.72

10506

91.58

... More
Fish Plate 50x6 mm., 2.36 kg/Mtr., each 0.280 mtr. length, 6 no's required = (6x2.36x0.280)

7.93

931

117.49

... More
AB Switch Mounting Channel 75x40x4.8 mm GI Channel (3000 mm long)(7.14Kg./Mtr., 2 No's.) (Each 2x3.000x7.14= 42.84 Kg)

85.68

7846

91.58

... More
AB Switch Side Support Channel 100X50X6mm,9.56 KG/Mtr., each channel length 0.35 mtr., 2 no's channel required =( 9.56x2x0.35)

13.38

1225

91.58

... More
Channel Support for down Pipe 75X40X 4.8mm., 7.14KG/Mtr., each channel length 0.8 Mtr., 1 no's channel required =( 7.14x0.8x1)

11.42

1046

91.58

... More
HG/ DO Fuse Mounting Channel 75x40x4.8 mm GI Channel (3000 mm long)(7.14Kg./Mtr., 2 No's.) (Each 2x3.000x7.14= 42.84 Kg)

85.68

7846

91.58

... More
Cantilever Support Channel 75x40x4.8 mm GI Channel (810 mm long,2 No's.) (7.14Kg./Mtr., 2 No's.) (Each 2x0.810x7.14= 11.57 Kg)

23.13

2118

91.58

... More
Cantilever Support Angle 50 X 50 X 6MM GI (1282 mm long) (4.5Kg./Mtr, 2 No's.) (Each 2x1.282x4.5= 11.54Kg)

23.08

2113

91.58

... More
Transformer Base GI Channel 100 X 50 X 6 MM (3000 mm long) (9.56Kg./Mtr, 2 No's.) (Each 2x3.000x9.56= 57.36 Kg)

114.72

10506

91.58

... More
Transformer Base Support GI Channel 100 X 50 X 6 MM (515 mm long) (9.56Kg./Mtr, 2 No's) (Each 2x0.515x9.56= 9.85Kg)

19.69

1803

91.58

... More
Transformer Belting Angle 50 X 50 X 6MM GI (3000 mm long)(4.5Kg./Mtr, 2 No's) (Each 2x3.0x4.5 Kg)

54

4945

91.58

... More
Transformer Belting Support Angle 50 X 50 X 6MM GI (580 mm long)(4.5Kg./Mtr,2 No's) (Each 2x0.580x4.5= Kg)

10.44

956

91.58

... More
LTDB Mounting Angle 50 X 50 X 6MM GI (1000 mm long)(4.5Kg./Mtr, 2 No's) (Each 2x1x4.5 Kg)

18

1648

91.58

... More
50x6mm GI Flat for earthing, 2.36kg/mtr., (2.5x7 mtr. For mesh formation, 12 Mtr. For LA and 2.5 mtr. For raising, 11 mtr for AB switch, 2.8 mtr for HG Fuse, 5x2 mtr. for DTR Nutral, (1.3+4.5) mtr. For DTR Body, 0.500 mtr for LTDB & AB Switch operating handle, 3 mtr. for Fencing) ( Each 65.6x 2.36= 154.81 Kg)

309.63

36377

117.49

... More
55mm2 All Alloy Aluminum Conductor (AAAC) - PVC Insulated (50 Mtr. Each Dtr.)

100

6656

66.56

... More
4 Cx 95 mm2 LT XLPE Cable(Armoured) - FOR 63 KVA Trf.

30

17337

577.93

... More
AB Switch(11KV,200A.3pole,50Hz)

2

23027

11513.78

... More
H.G.Fuse( 11KV.200A.3Pole)

2

19173

9586.98

... More
PG Clamp for 55 sq.mm AAA conductor

12

9023

751.92

... More
Disc insulator (B&S)70 KN polymer

6

10808

1801.48

... More
H W fitting (B&S)70KN(3bolted)

6

3289

548.28

... More
Lightning Arrester(12KV,10KA) Station Class 2

6

33366

5561.08

... More
11KV pin insulator polymer

6

1879

313.3

... More
HT stay set complete

4

6579

1644.83

... More
HT stay Clamp (1.9Kg/pair)

4

783

195.81

... More
HT stay insulator TYPE-C

4

313

78.33

... More
7/10 SWG GI stay wire, Grade -2 (15Kg./ Set)

60

7049

117.49

... More
40 mm Nominal bore GI pipe (medium gauge) earthing device with 3 mtr .Long

14

23027

1644.83

... More
GI Nuts & Bolts of Assorted size (25 Kg/ DSS DP)

50

6109

122.19

... More
GI Barbed wire/Anticlimbing device (3Kg /Pole)

12

1503

125.32

... More
Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 8 no's = (8x0.59x0.510)

4.81

565

117.49

... More
Danger plate 11kv

4

501

125.32

... More
Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 2 no's = (2x0.59x0.510)

1.2

141

117.49

... More
Name plate

2

250

125.32

... More
Structure Numbering and Marking Yellow Colour Paint for Background

4

1041

260.28

... More
Black Colour Paint for numbering

2

689

344.63

... More
Concreting ratio 1:1.5:3 (500mmX500mmX1800mm) = 0.450Cu.mtr (For WPB Pole)

1.8

11817

6565

... More
Couping ratio 1:1.5:3 (500mmX500mmX450mm) = 0.113Cu.mtr

0.45

2967

6565

... More
Fixing of stay set with 0.5Cum cement concrete foundation 1:3:6 size ( 900mmx600mmx900mm) using 40mm BHG metal with all labor and material except stay set , stay wire , stay insulator .

4

9090

2272.5

... More
Construction Earthing chamber including installation of earthing pipe.Making earthing chamber including excavation , soil treatment with bentonide powder , calculation of earth resistance, including Installation of 3Mtr GI Pipe 40mm/50mm including welding of GI flat around pipe .

14

52318

3737

... More
Laying of 4 Cx 95 mm2 LT XLPE Cable

30

1418

47.27

... More
Supply and Erection of GI Fencing with Gate

30

109080

3636

... More
Shifting and reconstruction of LT 3p5w line - 1.17 Km with 50mm2 ABC 9 Mtr. long 300 Kg. PSC Pole

35

178132

5089.5

... More
LT Stay set Complete

10

8145

814.58

... More
7/12 SWG GI stay wire, Grade -2

120

14098

117.49

... More
LT stay Clamp ( 1.40Kg/pair)

10

1723

172.32

... More
LT Stay insulator

10

470

47

... More
LT Accessories with Eye hook and ClampPole clamp for EYE hook for (XLPE Aerial bunched Cable)

45

14098

313.3

... More
EYE hook for XLPE Aerial bunched Cable (25-70 sq.mm)

20

1879

93.99

... More
Dead End Clamp suitable for messenger XLPE Aerial bunched Cable (25-70 sq.mm)

20

2036

101.82

... More
Suspension Clamp with EYE hook for ABC (25-70 sq.mm)

25

13315

532.61

... More
3x50 + 1x35 mm2 (LT AB Cable)

1228.5

250184

203.65

... More
Insulated piercing connector.Type-A-main 50 to 150 sq.mm & Tap-50 to 150 sq.mm

18

2452

136.26

... More
GI Pipe Earthing (each 5th pole to earth)

7

11513

1644.83

... More
Coil Earthing

28

7281

260.04

... More
No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing

9.17

1077

117.49

... More
Danger plate (LT)

35

4386

125.32

... More
Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 1 no's = (1x0.59x0.510)

10.53

1237

117.49

... More
GI barbed wire anticlimbing device 3 Kg. Per support

105

13158

125.32

... More
Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 4 no's = (4x0.59x0.510)

42.13

4949

117.49

... More
GI Nut , Bolt & Washer of different sizes (0.5 Kg/ Pole)

17.5

2138

122.19

... More
Black Paint

35

12062

344.63

... More
Yellow Colour Paint for Background

70

18219

260.28

... More
Fixing of LT Complete stay set includes 1) Turn Buckle Assembly 2) Stay Rod & Stay plate 3) Stay Insulator 4) Stay Wire. 5)Stay clamps with Nuts & bolts, including excvation, supply of 0.5Cum cement concrete foundation 1:2:4 size (500mmx500mmx800mm) using 20mm BHG metal with all labour and material (Excavation of earth will be done of size 500X500X1500 mm.)

10

22725

2272.5

... More
Concreting ratio 1:1.5:3 (500mmX500mmX1500mm) = 0.375Cu.mtr

13.13

86165

6565

... More
Construction Earthing chamber including installation of earthing pipe.Making earthing chamber including excavation , soil treatment with bentonide powder , calculation of earth resistance, including Installation of 3Mtr GI Pipe 40mm/50mm including welding of GI flat around pipe .

7

26159

3737

... More
Dismantling Portion Dismantling of 25 KVA DTR

2

3000

1500

... More
Dismantling of 63 KVA DTR

2

3600

1800

... More
Dismantling of100 KVA DTR

1

3189

3189.6

... More
Dismantling of PSC Poles

40

36000

900

... More
Dismantling of WPB poles

22

29700

1350

... More
Dismantling of Conductor

6700

60300

9

... More
Dismantling of LT ABC with Accessories

1110

24975

22.5



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.