Works Department Tender

Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.

Works Department - EICCL Tender

Works
Civil And Construction
Road Construction
Eprocure
Opening Date1 Nov 2024
Closing Date16 Nov 2024
Tender Amount₹ 48,26,850 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Double Pole Belting Channel 75X40X 4.8mm., 7.14KG/Mtr., each channel length 1.66 Mtr., 4 no's channel required =( 7.14x1.66x4)

47.41

91

4341.77

... More
50x50x6mm.GI Bracing Angle, 4.5Kg./mtr., each angle length 2.671 mtr., 4 nos angle required = (4.5x2.671x4)

48.08

91

4402.98

... More
Danger Plate, 2 no's.

2

125

250.64

... More
Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 2 no's = (2x0.59x0.510)

0.6

117

70.71

... More
H.T. Stay clamp, 50x8 mm. flat, 3.14Kg/Mtr., 0.551 Mtr. Length, 2 no's qty. required ( 1 Pair)

2

195

391.62

... More
H.T. Stay set (Complete )

2

1644

3289.66

... More
H.T. Stay Insulator Type-C

2

78

156.66

... More
7/10 SWG Stay Wire 15kg /stay

30

117

3524.7

... More
Gi Pipe Earthing 40mm. 3 Mtr. Long

1

1644

1644.83

... More
50x6mm GI Flat for earthing, 2.36kg/mtr., (2.5 mtr. For mesh formation and 2.5 mtr. For raising)= 5x2.36

11.8

117

1386.38

... More
GI barbed wire anticlimbing device 3 Kg. Per support, 2 no's qty. required =(2x3kg)

6

125

751.92

... More
Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 8 no's = (8x0.59x0.510)

2.41

117

282.82

... More
11 KV pin insulator polymer

3

313

939.9

... More
H W fitting(B&S) 70KN, 3Bolt

6

548

3289.68

... More
Disc insulator (B&S) 70 KN polymer

6

1801

10808.88

... More
PG Clamp for 80 sq.mm AAA conductor

6

830

4981.5

... More
GI Nut , Bolt & Washer of different sizes (12.261 Kg each DP without AB Switch)

12.26

122

1498.17

... More
Black Paint

1

344

344.63

... More
Yellow Colour Paint for Background

2

260

520.56

... More
Fixing of complete 11KV line Complete stay set includes 1) Turn Buckle Assembly 2) Stay Rod & Stay plate 3) Stay Insulator 4) Stay Wire. 5)Stay clamps with Nuts & bolts BA will do the excvation including excvation, supply of 0.5Cum cement concrete foundation 1:2:4 size ( 500mmx500mmx800mm) using 20mm BHG metal with all labour and material as per TPCODL Drawing & Standard.

2

2272

4545

... More
Concreting ratio 1:1.5:3 (500mmX500mmX1800mm) = 0.45Cu.mtr

0.9

6565

5908.5

... More
Couping ratio 1:1.5:3 with dimension (500X500X450)= 0.1125 Cu mtr

0.23

6565

1477.13

... More
Construction Earthing chamber including installation of earthing pipe.Making earthing chamber including excavation , soil treatment with bentonide powder , calculation of earth resistance, including Installation of 3Mtr GI Pipe 40mm/50mm including welding of GI flat around pipe .

1

3737

3737

... More
WPB (GI) Pole 160x152 (11Mtr. Long, 30.44KG/Mtr.)

2

34258

68516.92

... More
Top Channel 100X50X6mm, 9.56 KG/Mtr., each channel length 3 mtr., 2 no's channel required =( 2x9.56x3)

57.36

91

5253.03

... More
Fish Plate 50x6 mm., 2.36 kg/Mtr., each 0.280 mtr. length, 6 no's required = (6x2.36x0.280)

3.96

117

465.82

... More
AB switch Mounting Channel 75X40X4.8mm, 7.14KG/Mtr, each channel length 3 Mtr., 2 no's channel required =( 7.14x3x2)

42.84

91

3923.29

... More
AB Switch Side Support Channel 100X50X6mm,9.56 KG/Mtr., each channel length 0.35 mtr., 2 no's channel required =( 9.56x2x0.35)

6.69

91

612.85

... More
Channel Support for down Pipe 75X40X 4.8mm., 7.14KG/Mtr., each channel length 0.8 Mtr., 1 no's channel required =( 7.14x0.8x1)

5.71

91

523.1

... More
Double Pole Belting Channel 75X40X 4.8mm., 7.14KG/Mtr., each channel length 3.0 Mtr., 4 no's channel required =( 7.14x3x4)

85.68

91

7846.57

... More
50x50x6mm.GI Bracing Angle, 4.5Kg./mtr., each angle length 3.512 mtr., 4 nos angle required = (4.5x3.512x4)

63.22

91

5789.32

... More
Danger Plate, 2 no's.

2

125

250.64

... More
Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 2 no's = (2x0.59x0.510)

0.6

117

70.71

... More
H.T. Stay clamp, 50x8 mm. flat, 3.14Kg/Mtr., 0.551 Mtr. Length, 2 no's qty. required ( 1 Pair)

2

195

391.62

... More
H.T. Stay set (Complete )

2

1644

3289.66

... More
H.T. Stay Insulator Type-C

2

78

156.66

... More
7/10 SWG Stay Wire 15kg /stay

30

117

3524.7

... More
Gi Pipe Earthing 40mm. 3 Mtr. Long

2

1644

3289.66

... More
50x6mm GI Flat for earthing, 2.36kg/mtr., (12.5 Mtr. For L.A, 3 Mtr for AB Switch Body, 2.5 mtr. For mesh formation and 2.5 mtr. For raising)= 20.5x2.36

48.38

117

5684.17

... More
GI barbed wire anticlimbing device 3 Kg. Per support, 2 no's qty. required =(2x3kg)

6

125

751.92

... More
Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 8 no's = (8x0.59x0.510)

2.41

117

282.82

... More
Lightning Arrester(12KV,10KA) (Station Class,class-2)

3

5561

16683.24

... More
AB Switch (11KV,400A.3pole,50Hz)

1

18563

18563.03

... More
11 KV pin insulator polymer

3

313

939.9

... More
H W fitting(B&S) 70KN, 3Bolt

6

548

3289.68

... More
Disc insulator (B&S) 70 KN polymer

6

1801

10808.88

... More
PG Clamp for 80 sq.mm AAA conductor

6

830

4981.5

... More
GI Nut , Bolt & Washer of different sizes (13.718 Kg each DP with AB Switch)

13.72

122

1676.2

... More
Black Paint

1

344

344.63

... More
Yellow Colour Paint for Background

2

260

520.56

... More
Fixing of complete 11KV line Complete stay set includes 1) Turn Buckle Assembly 2) Stay Rod & Stay plate 3) Stay Insulator 4) Stay Wire. 5)Stay clamps with Nuts & bolts BA will do the excvation including excvation, supply of 0.5Cum cement concrete foundation 1:2:4 size ( 500mmx500mmx800mm) using 20mm BHG metal with all labour and material as per TPCODL Drawing & Standard.

2

2272

4545

... More
Concreting ratio 1:1.5:3 (500mmX500mmX1800mm) = 0.45Cu.mtr

0.9

6565

5908.5

... More
Couping ratio 1:1.5:3 with dimension ( 500X500X450)= 0.1125 Cu mtr

0.23

6565

1477.13

... More
Construction Earthing chamber including installation of earthing pipe.Making earthing chamber including excavation , soil treatment with bentonide powder , calculation of earth resistance, including Installation of 3Mtr GI Pipe 40mm/50mm including welding of GI flat around pipe .

2

3737

7474

... More
11 KV Cut Point with 90 Degree Angle (8nos.) WPB (GI) Pole 160x152 (11Mtr. Long, 30.44KG/Mtr.)

8

34258

274067.68

... More
Straight Cross Arm 100X50X6mm, 9.56 KG/Mtr., each channel length 1.2 mtr., 4 no's channel required =( 4x9.56x1.2)

367.1

91

33619.38

... More
Fish Plate 50x6 mm., 2.36 kg/Mtr., each 0.280 mtr. length, 16 no's required = (16x2.36x0.280)

84.58

117

9937.59

... More
Straight Cross Arm 100X50X6mm, 9.56 KG/Mtr., each channel length 0.306 mtr., 4 no's channel required =( 4x9.56x0.306)

93.61

91

8572.94

... More
Danger Plate, 1 no's.

8

125

1002.56

... More
Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 1 no's = (1x0.59x0.510)

2.41

117

282.82

... More
GI barbed wire anticlimbing device 3 Kg. Per support

24

125

3007.68

... More
Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 4 no's = (4x0.59x0.510)

9.63

117

1131.29

... More
11 KV pin insulator polymer

32

313

10025.6

... More
H W fitting(B&S) 70KN, 3Bolt

52.5

548

28784.7

... More
Disc insulator (B&S) 70 KN polymer

52.5

1801

94577.7

... More
Earthing of Support ( Coil Type )

8

260

2080.32

... More
No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing

2.1

117

246.26

... More
PG Clamp for 80 sq.mm AAA conductor

52.5

830

43588.13

... More
H.T. Stay clamp, 50x8 mm. flat, 3.14Kg/Mtr., 0.551 Mtr. Length, 2 no's qty. required ( 1 Pair)

16

195

3132.96

... More
H.T. Stay set (Complete )

16

1644

26317.28

... More
H.T. Stay Insulator Type-C

16

78

1253.28

... More
7/10 SWG Stay Wire 15kg /stay

240

117

28197.6

... More
GI Nut , Bolt & Washer of different sizes (7.433 Kg each Cut Pole)

59.46

122

7265.91

... More
Black Paint

4

344

1378.52

... More
Yellow Colour Paint for Background

16

260

4164.48

... More
Fixing of complete 11KV line Complete stay set includes 1) Turn Buckle Assembly 2) Stay Rod & Stay plate 3) Stay Insulator 4) Stay Wire. 5)Stay clamps with Nuts & bolts BA will do the excvation including excvation, supply of 0.5Cum cement concrete foundation 1:2:4 size ( 500mmx500mmx800mm) using 20mm BHG metal with all labour and material as per TPCODL Drawing & Standard.

16

2272

36360

... More
Concreting ratio 1:1.5:3 (500mmX500mmX1800mm) = 0.45Cu.mtr

3.6

6565

23634

... More
Couping ratio 1:1.5:3 with dimension ( 500X500X450)= 0.1125 Cu mtr

0.9

6565

5908.5

... More
11 KV Pin Points With PSC PSC POLE 9 METER LONG 300 KG

45

5089

229027.5

... More
PSC Pole V cross Arm Back Clamp

45

125

5639.4

... More
11 KV V cross Arm (10.2 K.g. each )

45

1268

57099.15

... More
Top bracket 100x50X6 mm GI channel (2kg each)

45

234

10574.1

... More
Danger Plate, 1 no's. for each pole

45

125

5639.4

... More
Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 1 no's = (1x0.59x0.510)

13.5

117

1586.12

... More
GI barbed wire anticlimbing device 3 Kg. Per support

133

125

16667.56

... More
Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 4 no's = (4x0.59x0.510)

54.16

117

6363.26

... More
11 KV pin insulator polymer, 3 Nos. required for each support

133

313

41668.9

... More
Earthing of Support ( Coil Type )

45

260

11701.8

... More
No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing

11.79

117

1385.21

... More
GI Nut , Bolt & Washer of different sizes (1.45 Kg/ Pin Point)

65.25

122

7972.9

... More
55 mm2 AAAC

2.55

46995

119837.25

... More
80 mm2 AAAC

4.15

67359

279541.93

... More
Crimping type Midspan Compression Joint for 55 sq.mm AAA conductor

6

322

1933.86

... More
Black Paint

45

344

15508.35

... More
Yellow Colour Paint for Background

90

260

23425.2

... More
Concreting ratio 1:1.5:3 (500mmX500mmX1500mm) = 0.375 Cu.mtr

16.87

6565

110751.55

... More
Shifting & re-construction of 100 KVA SS - 1 No WPB (GI) Pole 160x152 (11Mtr. Long, 30.44KG/Mtr.)

2

34258

68516.9

... More
Top Channel GI 100 X 50 X 6 MM (3000 mm long) (9.56Kg./Mtr, 2 No's.) (Each 2x3.000x9.56= 57.36 Kg)

57.36

91

5253.03

... More
Fish Plate 50x6 mm., 2.36 kg/Mtr., each 0.280 mtr. length, 6 no's required = (6x2.36x0.280)

3.96

117

465.82

... More
AB Switch Mounting Channel 75x40x4.8 mm GI Channel (3000 mm long)(7.14Kg./Mtr., 2 No's.) (Each 2x3.000x7.14= 42.84 Kg)

42.84

91

3923.29

... More
AB Switch Side Support Channel 100X50X6mm,9.56 KG/Mtr., each channel length 0.35 mtr., 2 no's channel required =( 9.56x2x0.35)

6.69

91

612.85

... More
Channel Support for down Pipe 75X40X 4.8mm., 7.14KG/Mtr., each channel length 0.8 Mtr., 1 no's channel required =( 7.14x0.8x1)

5.71

91

523.1

... More
HG/ DO Fuse Mounting Channel 75x40x4.8 mm GI Channel (3000 mm long)(7.14Kg./Mtr., 2 No's.) (Each 2x3.000x7.14= 42.84 Kg)

42.84

91

3923.29

... More
Cantilever Support Channel 75x40x4.8 mm GI Channel (810 mm long,2 No's.) (7.14Kg./Mtr., 2 No's.) (Each 2x0.810x7.14= 11.57 Kg)

11.57

91

1059.29

... More
Cantilever Support Angle 50 X 50 X 6MM GI (1282 mm long) (4.5Kg./Mtr, 2 No's.) (Each 2x1.282x4.5= 11.54Kg)

11.54

91

1056.65

... More
Transformer Base GI Channel 100 X 50 X 6 MM (3000 mm long) (9.56Kg./Mtr, 2 No's.) (Each 2x3.000x9.56= 57.36 Kg)

57.36

91

5253.03

... More
Transformer Base Support GI Channel 100 X 50 X 6 MM (515 mm long) (9.56Kg./Mtr, 2 No's) (Each 2x0.515x9.56= 9.85Kg)

9.85

91

901.77

... More
Transformer Belting Angle 50 X 50 X 6MM GI (3000 mm long)(4.5Kg./Mtr, 2 No's) (Each 2x3.0x4.5 Kg)

27

91

2472.66

... More
Transformer Belting Support Angle 50 X 50 X 6MM GI (580 mm long)(4.5Kg./Mtr,2 No's) (Each 2x0.580x4.5= Kg)

5.22

91

478.05

... More
LTDB Mounting Angle 50 X 50 X 6MM GI (1000 mm long)(4.5Kg./Mtr, 2 No's) (Each 2x1x4.5 Kg)

9

91

824.22

... More
50x6mm GI Flat for earthing, 2.36kg/mtr., (2.5x7 mtr. For mesh formation, 12 Mtr. For LA and 2.5 mtr. For raising, 11 mtr for AB switch, 2.8 mtr for HG Fuse, 5x2 mtr. for DTR Nutral, (1.3+4.5) mtr. For DTR Body, 0.500 mtr for LTDB & AB Switch operating handle, 3 mtr. for Fencing) ( Each 65.6x 2.36= 154.81 Kg)

154.82

117

18189.33

... More
55mm2 All Alloy Aluminum Conductor (AAAC) - PVC Insulated (50 Mtr. Each Dtr.)

50

66

3328

... More
4 Cx 150 mm2 LT XLPE Cable(Armoured) - FOR 100 KVA Trf.

15

992

14893.95

... More
AB Switch(11KV,200A.3pole,50Hz)

1

11513

11513.77

... More
H.G.Fuse( 11KV.200A.3Pole)

1

9586

9586.98

... More
PG Clamp for 55 sq.mm AAA conductor

6

751

4511.52

... More
Disc insulator (B&S)70 KN polymer

3

1801

5404.41

... More
H W fitting (B&S)70KN(3bolted)

3

548

1644.81

... More
Lightning Arrester(12KV,10KA) Station Class 2

3

5561

16683.21

... More
11KV pin insulator polymer

3

313

939.9

... More
HT stay set complete

2

1644

3289.64

... More
HT stay Clamp (1.9Kg/pair)

2

195

391.62

... More
HT stay insulator TYPE-C

2

78

156.64

... More
7/10 SWG GI stay wire, Grade -2 (15Kg./ Set)

30

117

3524.63

... More
40 mm Nominal bore GI pipe (medium gauge) earthing device with 3 mtr .Long

7

1644

11513.78

... More
GI Nuts & Bolts of Assorted size (25 Kg/ DSS DP)

25

122

3054.68

... More
GI Barbed wire/Anticlimbing device (3Kg /Pole)

6

125

751.92

... More
Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 8 no's = (8x0.59x0.510)

2.41

117

282.82

... More
Danger plate 11kv

2

125

250.64

... More
Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 2 no's = (2x0.59x0.510)

0.6

117

70.7

... More
Name plate

1

125

125.32

... More
Structure Numbering and Marking Yellow Colour Paint for Background

2

260

520.56

... More
Black Colour Paint for numbering

1

344

344.63

... More
Concreting ratio 1:1.5:3 (500mmX500mmX1800mm) = 0.450Cu.mtr (For WPB Pole)

0.9

6565

5908.5

... More
Couping ratio 1:1.5:3 (500mmX500mmX450mm) = 0.113Cu.mtr

0.23

6565

1483.69

... More
Fixing of stay set with 0.5Cum cement concrete foundation 1:3:6 size ( 900mmx600mmx900mm) using 40mm BHG metal with all labor and material except stay set , stay wire , stay insulator .

2

2272

4545

... More
Construction Earthing chamber including installation of earthing pipe.Making earthing chamber including excavation , soil treatment with bentonide powder , calculation of earth resistance, including Installation of 3Mtr GI Pipe 40mm/50mm including welding of GI flat around pipe .

7

3737

26159

... More
Laying of 4 Cx 150 mm2 LT XLPE Cable

15

72

1090.8

... More
Supply and Erection of GI Fencing with Gate

15

3636

54540

... More
Shifting & re construction of 25 KVA SS- 3 nos, WPB (GI) Pole 160x152 (11Mtr. Long, 30.44KG/Mtr.)

6

34258

205550.73

... More
Top Channel GI 100 X 50 X 6 MM (3000 mm long) (9.56Kg./Mtr, 2 No's.) (Each 2x3.000x9.56= 57.36 Kg)

172.08

91

15759.09

... More
Fish Plate 50x6 mm., 2.36 kg/Mtr., each 0.280 mtr. length, 6 no's required = (6x2.36x0.280)

10.62

117

1247.72

... More
AB Switch Mounting Channel 75x40x4.8 mm GI Channel (3000 mm long)(7.14Kg./Mtr., 2 No's.) (Each 2x3.000x7.14= 42.84 Kg)

128.52

91

11769.86

... More
AB Switch Side Support Channel 100X50X6mm,9.56 KG/Mtr., each channel length 0.35 mtr., 2 no's channel required =( 9.56x2x0.35)

20.08

91

1838.56

... More
Channel Support for down Pipe 75X40X 4.8mm., 7.14KG/Mtr., each channel length 0.8 Mtr., 1 no's channel required =( 7.14x0.8x1)

17.14

91

1569.31

... More
HG/ DO Fuse Mounting Channel 75x40x4.8 mm GI Channel (3000 mm long)(7.14Kg./Mtr., 2 No's.) (Each 2x3.000x7.14= 42.84 Kg)

128.52

91

11769.86

... More
Cantilever Support Channel 75x40x4.8 mm GI Channel (810 mm long,2 No's.) (7.14Kg./Mtr., 2 No's.) (Each 2x0.810x7.14= 11.57 Kg)

34.7

91

3177.86

... More
Cantilever Support Angle 50 X 50 X 6MM GI (1282 mm long) (4.5Kg./Mtr, 2 No's.) (Each 2x1.282x4.5= 11.54Kg)

34.61

91

3169.95

... More
Transformer Base GI Channel 100 X 50 X 6 MM (3000 mm long) (9.56Kg./Mtr, 2 No's.) (Each 2x3.000x9.56= 57.36 Kg)

172.08

91

15759.09

... More
Transformer Base Support GI Channel 100 X 50 X 6 MM (515 mm long) (9.56Kg./Mtr, 2 No's) (Each 2x0.515x9.56= 9.85Kg)

29.54

91

2705.31

... More
Transformer Belting Angle 50 X 50 X 6MM GI (3000 mm long)(4.5Kg./Mtr, 2 No's) (Each 2x3.0x4.5 Kg)

81

91

7417.98

... More
Transformer Belting Support Angle 50 X 50 X 6MM GI (580 mm long)(4.5Kg./Mtr,2 No's) (Each 2x0.580x4.5= Kg)

15.66

91

1434.14

... More
LTDB Mounting Angle 50 X 50 X 6MM GI (1000 mm long)(4.5Kg./Mtr, 2 No's) (Each 2x1x4.5 Kg)

27

91

2472.66

... More
50x6mm GI Flat for earthing, 2.36kg/mtr., (2.5x7 mtr. For mesh formation, 12 Mtr. For LA and 2.5 mtr. For raising, 11 mtr for AB switch, 2.8 mtr for HG Fuse, 5x2 mtr. for DTR Nutral, (1.3+4.5) mtr. For DTR Body, 0.500 mtr for LTDB & AB Switch operating handle, 3 mtr. for Fencing) ( Each 65.6x 2.36= 154.81 Kg)

464.45

117

54566.83

... More
55mm2 All Alloy Aluminum Conductor (AAAC) - PVC Insulated (50 Mtr. Each Dtr.)

150

66

9984.63

... More
4 Cx 35 mm2 LT XLPE Cable(Armoured) - FOR 25 KVA Trf.

45

257

11570.53

... More
AB Switch(11KV,200A.3pole,50Hz)

3

11513

34541.33

... More
H.G.Fuse( 11KV.200A.3Pole)

3

9586

28760.94

... More
PG Clamp for 55 sq.mm AAA conductor

18

751

13534.56

... More
Disc insulator (B&S)70 KN polymer

9

1801

16213.28

... More
H W fitting (B&S)70KN(3bolted)

9

548

4934.47

... More
Lightning Arrester(12KV,10KA) Station Class 2

9

5561

50049.67

... More
11KV pin insulator polymer

9

313

2819.7

... More
HT stay set complete

6

1644

9868.95

... More
HT stay Clamp (1.9Kg/pair)

6

195

1174.88

... More
HT stay insulator TYPE-C

6

78

469.95

... More
7/10 SWG GI stay wire, Grade -2 (15Kg./ Set)

90

117

10573.88

... More
40 mm Nominal bore GI pipe (medium gauge) earthing device with 3 mtr .Long

21

1644

34541.33

... More
GI Nuts & Bolts of Assorted size (25 Kg/ DSS DP)

75

122

9164.03

... More
GI Barbed wire/Anticlimbing device (3Kg /Pole)

18

125

2255.76

... More
Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 8 no's = (8x0.59x0.510)

7.22

117

848.45

... More
Danger plate 11kv

6

125

751.92

... More
Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 2 no's = (2x0.59x0.510)

1.81

117

212.11

... More
Name plate

3

125

375.96

... More
Structure Numbering and Marking Yellow Colour Paint for Background

6

260

1561.68

... More
Black Colour Paint for numbering

3

344

1033.89

... More
Concreting ratio 1:1.5:3 (500mmX500mmX1800mm) = 0.450Cu.mtr (For WPB Pole)

2.7

6565

17725.5

... More
Couping ratio 1:1.5:3 (500mmX500mmX450mm) = 0.113Cu.mtr

0.68

6565

4451.07

... More
Fixing of stay set with 0.5Cum cement concrete foundation 1:3:6 size ( 900mmx600mmx900mm) using 40mm BHG metal with all labor and material except stay set , stay wire , stay insulator .

6

2272

13635

... More
Construction Earthing chamber including installation of earthing pipe.Making earthing chamber including excavation , soil treatment with bentonide powder , calculation of earth resistance, including Installation of 3Mtr GI Pipe 40mm/50mm including welding of GI flat around pipe .

21

3737

78477

... More
Laying of 4 Cx 35 mm2 LT XLPE Cable

45

47

2127.06

... More
Supply and Erection of GI Fencing with Gate

45

3636

163620

... More
Shifting & re construction of 63 KVA SS-3 Nos WPB (GI) Pole 160x152 (11Mtr. Long, 30.44KG/Mtr.)

6

34258

205550.73

... More
Top Channel GI 100 X 50 X 6 MM (3000 mm long) (9.56Kg./Mtr, 2 No's.) (Each 2x3.000x9.56= 57.36 Kg)

172.08

91

15759.09

... More
Fish Plate 50x6 mm., 2.36 kg/Mtr., each 0.280 mtr. length, 6 no's required = (6x2.36x0.280)

11.89

117

1397.44

... More
AB Switch Mounting Channel 75x40x4.8 mm GI Channel (3000 mm long)(7.14Kg./Mtr., 2 No's.) (Each 2x3.000x7.14= 42.84 Kg)

128.52

91

11769.86

... More
AB Switch Side Support Channel 100X50X6mm,9.56 KG/Mtr., each channel length 0.35 mtr., 2 no's channel required =( 9.56x2x0.35)

20.08

91

1838.56

... More
Channel Support for down Pipe 75X40X 4.8mm., 7.14KG/Mtr., each channel length 0.8 Mtr., 1 no's channel required =( 7.14x0.8x1)

17.14

91

1569.31

... More
HG/ DO Fuse Mounting Channel 75x40x4.8 mm GI Channel (3000 mm long)(7.14Kg./Mtr., 2 No's.) (Each 2x3.000x7.14= 42.84 Kg)

128.52

91

11769.86

... More
Cantilever Support Channel 75x40x4.8 mm GI Channel (810 mm long,2 No's.) (7.14Kg./Mtr., 2 No's.) (Each 2x0.810x7.14= 11.57 Kg)

34.7

91

3177.86

... More
Cantilever Support Angle 50 X 50 X 6MM GI (1282 mm long) (4.5Kg./Mtr, 2 No's.) (Each 2x1.282x4.5= 11.54Kg)

34.61

91

3169.95

... More
Transformer Base GI Channel 100 X 50 X 6 MM (3000 mm long) (9.56Kg./Mtr, 2 No's.) (Each 2x3.000x9.56= 57.36 Kg)

172.08

91

15759.09

... More
Transformer Base Support GI Channel 100 X 50 X 6 MM (515 mm long) (9.56Kg./Mtr, 2 No's) (Each 2x0.515x9.56= 9.85Kg)

29.54

91

2705.31

... More
Transformer Belting Angle 50 X 50 X 6MM GI (3000 mm long)(4.5Kg./Mtr, 2 No's) (Each 2x3.0x4.5 Kg)

81

91

7417.98

... More
Transformer Belting Support Angle 50 X 50 X 6MM GI (580 mm long)(4.5Kg./Mtr,2 No's) (Each 2x0.580x4.5= Kg)

15.66

91

1434.14

... More
LTDB Mounting Angle 50 X 50 X 6MM GI (1000 mm long)(4.5Kg./Mtr, 2 No's) (Each 2x1x4.5 Kg)

27

91

2472.66

... More
50x6mm GI Flat for earthing, 2.36kg/mtr., (2.5x7 mtr. For mesh formation, 12 Mtr. For LA and 2.5 mtr. For raising, 11 mtr for AB switch, 2.8 mtr for HG Fuse, 5x2 mtr. for DTR Nutral, (1.3+4.5) mtr. For DTR Body, 0.500 mtr for LTDB & AB Switch operating handle, 3 mtr. for Fencing) ( Each 65.6x 2.36= 154.81 Kg)

464.45

117

54566.83

... More
55mm2 All Alloy Aluminum Conductor (AAAC) - PVC Insulated (50 Mtr. Each Dtr.)

150

66

9984.63

... More
4 Cx 95 mm2 LT XLPE Cable(Armoured) - FOR 63 KVA Trf.

45

577

26006.85

... More
AB Switch(11KV,200A.3pole,50Hz)

3

11513

34541.33

... More
H.G.Fuse( 11KV.200A.3Pole)

3

9586

28760.94

... More
PG Clamp for 55 sq.mm AAA conductor

18

751

13534.56

... More
Disc insulator (B&S)70 KN polymer

9

1801

16213.28

... More
H W fitting (B&S)70KN(3bolted)

9

548

4934.47

... More
Lightning Arrester(12KV,10KA) Station Class 2

9

5561

50049.67

... More
11KV pin insulator polymer

9

313

2819.7

... More
HT stay set complete

6

1644

9868.95

... More
HT stay Clamp (1.9Kg/pair)

6

195

1174.88

... More
HT stay insulator TYPE-C

6

78

469.95

... More
7/10 SWG GI stay wire, Grade -2 (15Kg./ Set)

90

117

10573.88

... More
40 mm Nominal bore GI pipe (medium gauge) earthing device with 3 mtr .Long

21

1644

34541.33

... More
GI Nuts & Bolts of Assorted size (25 Kg/ DSS DP)

75

122

9164.03

... More
GI Barbed wire/Anticlimbing device (3Kg /Pole)

18

125

2255.76

... More
Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 8 no's = (8x0.59x0.510)

7.22

117

848.45

... More
Danger plate 11kv

6

125

751.92

... More
Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 2 no's = (2x0.59x0.510)

1.81

117

212.11

... More
Name plate

3

125

375.96

... More
Structure Numbering and Marking Yellow Colour Paint for Background

6

260

1561.68

... More
Black Colour Paint for numbering

3

344

1033.89

... More
Concreting ratio 1:1.5:3 (500mmX500mmX1800mm) = 0.450Cu.mtr (For WPB Pole)

2.7

6565

17725.5

... More
Couping ratio 1:1.5:3 (500mmX500mmX450mm) = 0.113Cu.mtr

0.68

6565

4451.07

... More
Fixing of stay set with 0.5Cum cement concrete foundation 1:3:6 size ( 900mmx600mmx900mm) using 40mm BHG metal with all labor and material except stay set , stay wire , stay insulator .

6

2272

13635

... More
Construction Earthing chamber including installation of earthing pipe.Making earthing chamber including excavation , soil treatment with bentonide powder , calculation of earth resistance, including Installation of 3Mtr GI Pipe 40mm/50mm including welding of GI flat around pipe .

21

3737

78477

... More
Laying of 4 Cx 95 mm2 LT XLPE Cable

45

47

2127.06

... More
Supply and Erection of GI Fencing with Gate

45

3636

163620

... More
Shifting and reconstruction of LT 3p5w line - 1.17 Km with 50mm2 ABC 9 Mtr. long 300 Kg. PSC Pole

35

5089

178132.5

... More
LT Stay set Complete

10

814

8145.8

... More
7/12 SWG GI stay wire, Grade -2

120

117

14098.8

... More
LT stay Clamp ( 1.40Kg/pair)

10

172

1723.2

... More
LT Stay insulator

10

47

470

... More
LT Accessories with Eye hook and Clamp Pole clamp for EYE hook for (XLPE Aerial bunched Cable)

45

313

14098.5

... More
EYE hook for XLPE Aerial bunched Cable (25-70 sq.mm)

20

93

1879.8

... More
Dead End Clamp suitable for messenger XLPE Aerial bunched Cable (25-70 sq.mm)

20

101

2036.4

... More
Suspension Clamp with EYE hook for ABC (25-70 sq.mm)

25

532

13315.25

... More
3x50 + 1x35 mm2 (LT AB Cable)

1228.5

203

250184.03

... More
Insulated piercing connector.Type-A-main 50 to 150 sq.mm & Tap-50 to 150 sq.mm

18

136

2452.68

... More
GI Pipe Earthing (each 5th pole to earth)

7

1644

11513.81

... More
Coil Earthing

28

260

7281.12

... More
No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing

9.17

117

1077.38

... More
Danger plate (LT)

35

125

4386.2

... More
Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 1 no's = (1x0.59x0.510)

10.53

117

1237.35

... More
GI barbed wire anticlimbing device 3 Kg. Per support

105

125

13158.6

... More
Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 4 no's = (4x0.59x0.510)

42.13

117

4949.38

... More
GI Nut , Bolt & Washer of different sizes (0.5 Kg/ Pole)

17.5

122

2138.33

... More
Black Paint

35

344

12062.05

... More
Yellow Colour Paint for Background

70

260

18219.6

... More
Fixing of LT Complete stay set includes 1) Turn Buckle Assembly 2) Stay Rod & Stay plate 3) Stay Insulator 4) Stay Wire. 5)Stay clamps with Nuts & bolts, including excvation, supply of 0.5Cum cement concrete foundation 1:2:4 size (500mmx500mmx800mm) using 20mm BHG metal with all labour and material (Excavation of earth will be done of size 500X500X1500 mm.)

10

2272

22725

... More
Concreting ratio 1:1.5:3 (500mmX500mmX1500mm) = 0.375Cu.mtr

13.13

6565

86165.63

... More
Construction Earthing chamber including installation of earthing pipe.Making earthing chamber including excavation , soil treatment with bentonide powder , calculation of earth resistance, including Installation of 3Mtr GI Pipe 40mm/50mm including welding of GI flat around pipe .

7

3737

26159

... More
Dismantling of 25 KVA DTR

3

1500

4500

... More
Dismantling of 63 KVA DTR

3

1800

5400

... More
Dismantling of100 KVA DTR

1

3189

3189.6

... More
Dismantling of PSC Poles

40

900

36000

... More
Dismantling of WPB poles

26

1350

35100

... More
Dismantling of Conductor

6700

9

60300

... More
Dismantling of LT ABC with Accessories

1110

22

24975



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.