Works Department Tender

Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.

Works Department - EICCL Tender

Works
Civil And Construction
Bridge Construction
Eprocure
Opening Date21 Nov 2024
Closing Date2 Dec 2024
Tender Amount₹ 69,57,668.79 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and applying of anticorrosive treatment to exposed structural reinforcement by two coats of IPNET RB or equivalent with time interval of minimum 8 -10 hours between each coat after the application of two coats of alkaline rust converting primer. The application shall be done by brush or spray after cleaning existing reinforcement with wire / rotary wire brush to make the surfaces free from loose material, dirt, traces of corrosion etc. and thoroughly washing with water and allowing it to dry inclusive of all labour, materials, equipment etc. complete in all respect as per specifications and instructions of Engineer in Charge.

643

409

263186.33

... More
Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.(Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make)

643

821

528385.25

... More
Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.(Up to 12 mm diameter (Quantity taken for estimate purpose approximately. Quantity may vary as per actual work) @ 50Rmt per span))

1100

9

10483

... More
Bars above 12 mm diameter (Quantity taken for estimate purpose approximately. Quantity may vary as per actual work) @ 50 Rmt per span)

1100

19

20977

... More
Shotcreting R.C.C. columns, beams, and slab etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineer- in-Charge. Note: Rate shall be include the providing necessary ground wire etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/tapping with a blunt metal instrument.(75 mm thick in Grade M 25 with cement content not less than 330 kg per cum)

293

1382

405060.78

... More
Providing and fixing hard drawn steel wire fabric of size 75 x 25 mm mesh or other suitable size wire mesh to be fixed & firmly anchored to the concrete surface by means of "L"shaped mild steel shear key welded with existing reinforcement including the cost of materials, labour, tool & plants as approved by the Engineer-In-Charge.

293

671

196699.69

... More
Providing , mixing and applying SBR polymer (of approved make) modified cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt of cement used) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and payment under this item shall be made only after proper wet curing has been done and surface has been satisfactory evaluated by sounding / tapping with a blunt metal instrument and/ or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N /mm2 .(50mm thickness in 3 Layers)

350

740

259073.5

... More
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.

10

1662

16621.1

... More
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.

216.98

276

59888.65

... More
Providing and laying in position ready mixed or site batched design mix M15 grade cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural source, Portland Pozzolona/Ordinary Portland / Portland Slag cement, admixture in recommended proportions as per IS:9103 to accelerate /retard setting of concrete , to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing , carriage for all leads; but excluding the cost of cantering , shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.

7.88

6198

48845.05

... More
Providing & Laying Design M-40 grade concrete (Note : Min. Cement content considered in M-40 is @ 390 kg/ cum)(For approach slab )

15.75

7277

114616.37

... More
Centering and shuttering including strutting, propping etc. and removal of form work for :

28.7

369

10618.43

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.

632

87

55028.24

... More
Providing and laying of neoprene seal in expansion joint for horizontal movement, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instructions for installation complete work.

187

3252

608296.04

... More
Providing and fixing drainage spouts complete as per IRC: SP-42 with 100 mm dia PVC pipe and down-take length 1m as per engineer-in-charge.

220

1199

263986.8

... More
Providing and fixing Glow studs of size 100x20 mm made of heavy duty body shall be moulded ASA (Acrylic styrene Acrylonitrile) or HIP (High impact polystyrene) or ABS having electronically welded micro- prismatic lens with abrasion resistant coating as approved by Engineer in charge. The glow stud shall support a load of 13635 kg tested in accordance with ASTM D4280. The slope of retro- reflective surface shall be 35 (+/-5) degrees to base .The reflective panels on both sides with at least 12 cm of reflective area up each side. The luminance intensity should be as per the specification and shall be tested as described in ASTM I: 809 as recommended in BS: 873 part 4: 1973. The studs shall be fixed to the Road surface using the adhesive conforming to IS, as per procedure recommended by the manufacturer complete and as per direction of Engineer-in-charge.

220

468

103131.6

... More
Providing and painting of Anticorrosive paint on exposed surface of superstructures and complete as per specifications and manufacture's recommendation by approved supplier as per the direction of Engineer-in-Charge.

14971.94

179

2688511.27

... More
Cleaning and removing vegetation as and where required.

616.36

8

5097.3

... More
Providing and inserting 12mm dia galvanised steel injection nipple in honey comb area and along crack line including drilling of holes of required diameter (20mm to 30mm) up to depth 30mm to 80mm at required spacing making the hole & cracks dust free by blowing compressed air , sealing the distance between injection nipple with adhesive chemical of approved make and allow it to cure complete as per direction of Engineer-in-charge.

1000

157

157030

... More
Providing and injecting grout in proportion recommended by the manufacturer into cracks/honey-comb area of concrete / masonry by suitable gun/pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-in-charge. (Epoxy Injection grout in concrete/RCC work of approved make.)

500

830

415360

... More
Providing and placing high strength, non shrink pre-packed free flow micro concrete having compressive strength of 60 MPa at 28 days (compressive strength of one day should not be less than 25 MPa) as per specifications. The micro concrete mix shall be prepared by mixing non shrink pre-packed free flow micro concrete powder with well graded cleaned crushed, aggregate 10mm & down (aggregate should be less than 10mm but retained on 3.36mm) in proportion of 2:1 (Two part pre-pack micro concrete powder : one part stone aggregate) by weight for repairing excessively damaged area of structural elements excluding reinforcement but including scaffolding, curing inclusive of all labour, materials, equipment etc. complete as per specifications and instructions of Engineer-in-Charge.

5

46281

231408.45

... More
Providing and applying 2.5 mm thick road marking strips (retro- reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of Engineer-in-charge and accordance with applicable specifications.

302.94

280

85110.99

... More
Providing and fixing retro reflecting sign board.

2

5894

11789.5

... More
Providing and applying stone pitching as per drawing/engineer in charge.

18

2327

41887.98

... More
Providing and applying cement grout in stone masonry about 100mm thick complete work as per drawing/engineer in charge.

160

830

132915.2



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.