Scheduled Tribes And Scheduled Castes Development Department Tender
Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.
Scheduled Tribes And Scheduled Castes Development Department Tender
Civil And Construction
Building Construction
Eprocure
Opening Date6 Jun 2023
Closing Date16 Jun 2023
Tender AmountRefer Documents
Costs
EMD
₹ 27,755Document Cost
₹ 6,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_STSCD_89645_28Bid Award Id
ViewTender No
02/2023-24Tender Authority
Scheduled Tribes And Scheduled Castes Development Department ViewPurchaser Address
-Website
http://http://stscodisha.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Ground Floor
999.09
40662
40.7
First Floor
1404.23
60101
42.8
4 cm thick grading concrete in CC (1:2:4) on roof slab with 12mm and downgraded size cb chips for old work with cost, conveyance, royalty of all materials etc complete
-
-
-
First Floor
294.92
191639
649.8
Supplying of M.S Doors, Window with grills, Grills,Collapsible gates made out of M.S Angle frame, M.s Flat Sheet etc. of approved section and design, electrically welded properly with all necessary locking arrangement and one coat redoxide primer including cost of all materials, labour, T&P, carriage of materials to site etc. complete as per the direction of the Engineer-in-charge.
1705.87
218010
127.8
Labour charges for fitting and fixing of door and window shutter with all complete work
42.84
3354
78.3
16mm thick cement plaster (1:6) in cement mortar finished smooth surface on brick wall after racking out joints including watering curing to required period including cost conveyance, royalty of all materials, T&P complete etc. as per specification and direction of Engineer in charge.
-
-
-
Ground Floor
482.83
96566
200
First Floor
646.67
133602
206.6
12mm thick cement plaster (1:6) in cement mortar finished smooth surface on brick wall after racking out joints including watering curing to required period including cost conveyance, royalty of all materials, T&P complete etc. as per specification and direction of Engineer in charge.
-
-
-
Ground Floor
469.33
65518
139.6
First Floor
713.97
103668
145.2
6mm thick cement plaster in cement mortar(1:4) to RCC surface finished including watering curing to required period including cost conveyance, royalty of all materials, T&P complete etc. as per specification and direction of Engineer in charge.
-
-
-
Ground Floor
334.81
52732
157.5
First Floor
296.91
47950
161.5
Providing and fixing chicken wiremash on joints of RCC (Beam & Coloumn with brick work )Brick ,Block ,Ele Conduit Work (over the Chasing Work ) Before plastering with nail /Screw Complete satisfaction as per the engineer in charges /Architect.
100
14000
140
Painting two coats of synthetic enamel paint over a coat of primer of approved quality, brand and shade including smoothening the surface by sand paper and filler etc complete with cost, conveyance, royalty, taxes of all materials, labours T&P required as per specification and direction of Engineer-in-charge.
-
-
-
Ground Floor
115.63
22825
197.4
First Floor
115.63
23403
202.4
Wall painting two coats with plastic emulsion paint over putty work and one coat primer with cost, conveyance, royalty, taxes of all materials labour T&P and scaffolding as required for the work and as per direction of Engineer-in-charge.
-
-
-
Ground Floor
1512.24
358400
237
First Floor
943.58
228440
242.1
Finishing to walls with two coats weather coat over one coat primer after finishing wall surface of wall with cement based wall putty (water based) and weather coat paint of approved brand and approved colour including cleaning the surface with cost, conveyance, royalty taxes of all materials labour T&P and scaffolding as required for the work and as per specification and direction of Engineer-in-charge.
-
-
-
Ground Floor
727.88
183571
252.2
First Floor
713.97
184775
258.8
RCC work of M-20 grade with 20 mm and down grade black hard granite chips including cost, conveyance, royalty and all taxes of all materials with all leads, lifts, T&P etc including rigid and smooth centering, shuttering and dismantling the same after the curing of RCC work for 28 days complete the item of work in all respect as per specification and direction of Engineer-in-charge.
-
-
-
(a) Column & Beam
-
-
-
Second Floor
1.66
22746
13702.6
(b) Roof Slab
-
-
-
Second Floor
2.39
27067
11325.2
Labour charges for straightening coiled or bent up MS rods including cutting, bending and welding if required and tying the grills, laying and placing in proper position as per design including cost, conveyance, taxes etc of tested MS/TS rod with testing data of required specification & cost of binding wires of 18 to 20 gauge, labour, T&P required for the work complete and as per the specification and direction of the Engineer-in-charge.
-
-
-
Second Floor
5.04
53479
10611.1
Brick work with Flyash bricks of size 23 cm X 11 cm X 8 cm having crushing strength between 100 Kg/cm2 to 149 kg/cm2 in cement mortar (1:6) in superstructure including cost, conveyance, royalty, taxes of all materials, labour, T&P required for the work complete and as per the direction of the Engineer-in-charge.
9.36
47830
5110.1
Renovation of Electrical work
-
-
-
Surface/ recessed wiring to light point with ISI marked 1.5 Sq. mm PVC S/C Al Multistand copper wire in 20 mm dia PVC conduit and S/F of 5A Modular switch mounted on M.S. Board ( Make if wire Anchor/Phinolex/ Havelles/V-Guard/ L & T) as per the direction of the Engineer -in-Charge.
-
-
-
(a) Group-A
48
23040
480
(b) Group-B
100
70600
706
(c) Group-C
36
35640
990
Surface/ recessed wiring to fan point with ISI marked 1.5 Sq. mm PVC S/C Al Multistand copper wire in 20 mm dia PVC conduit and S/F of 5A modular switch mounted on M.S. Board as per the direction of Engineer-in-Charge
-
-
-
(a) Group-B
76
53656
706
Surface/recessed wiring to 5 pin 5A plug point with ISI marked 1.5 Sq.mm PVC S/C Al multistand copper wire in 20 mm dia PVC conduct and S/F of 5A modular flush type socket with switch mounted on M.S. Board as per the Direction of the Engineer -in-Charge
-
-
-
(a) Per Point
6
2550
425
(b) On existing board
52
11024
212
S/F of 3 pin plug point with ISI marked 4 Sq. mm S/C Al/Multistand coper wire in 20mm dia PVC conduit and S/F of 15 A flush type modular socket with 15 A modular switch on M.S. Board as per the Direction of Engineer - in-charge
4
1980
495
Surface/recessed wiring to sub main with S/F of ISI marked 2 x 2.5 Sq.mm Multistand copper wire in 20mm dia PVC conduit as per the direction of the Engineer-in-charge.
760
107920
142
Surface/recessed wiring to sub main with S/F of ISI marked 2 x 4 Sq. mm Multistand copper wire in 20mm dia PVC conduit as per the direction of the Engineer-in-charge.
180
28620
159
Surface/recessed wiring to sub main with S/F of ISI marked 2 x 6 Sqmm '+ 1 x 2.5 Sqmm Multistand copper wire in 20mm dia PVC conduit as per the direction of the Engineer-in-charge.
60
11400
190
Surface/recessed wiring to sub main with S/F of ISI marked 2 x 1.5 Sqmm Multistand copper wire in 20mm dia PVC conduit as per the direction of the Engineer-in-charge.
300
38400
128
S/F of ISI marked BK angle holder with shade out without bulb as per the direction of the Engineer-in-charge.
124
7316
59
S/F of ISI marked 6A M.C.B with busbar as per the direction of the Engineer-in-charge.
-
-
-
(a) 3 way
2
3008
1504
(b) 6 way
6
13788
2298
S/F of ISI marked 32A ICDP main switch on MS Board as per the direction of the Engineer-in-charge.
2
3090
1545
S/F of ISI marked 63A DP main switch on MS Board as per the direction of the Engineer-in-charge.
2
5700
2850
S/F of 48" AC ceiling fan with out regulator (Usha / Bajaj-Elegence / Havells make) as per the direction of the Engineer-in-charge.
29
74066
2554
S/F of 12" Exhaust Fan (Usha / Bajaj-Elegence / Havells make) as per the direction of the Engineer-in-charge.
18
34344
1908
S/F of Electronic fan Regulator ( Modular ) as per the direction of the Engineer-in-charge.
29
11020
380
(S/F of standard earthing as per Govt. specification as per the direction of the Engineer-in-charge.
2
4884
2442
S/F of service connection wire 2 x 6 Sq.mm with GI wire as per the direction of the Engineer-in-charge.
50
2250
45
S/F of 45W LED Street Light fitting complete (Bajaj/Havells/Philips) as per the direction of the Engineer-in-charge.
5
22500
4500
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements