Rural Water Supply And Sanitation Department Tender

... More
Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.

Rural Water Supply And Sanitation Department - RWSS Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date12 Jan 2024
Closing DateCancelled
Tender Amount₹ 6,64,466 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Fish plate 50x8mm,2.36 kg/mtr each 0.28 mtr. length 8 nos required= (8x2.36x0.28)

5.3

516

97.5

... More
Straight cross arm 100x50x6mm , 9.56 kg per mtr each channel length 0.306 mtr 2 nos channel required = (2x9.56x0.306)

5.9

448

76

... More
Danger Ptate, 1 no's.

1

104

104

... More
Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 1 no's = (1x0.59x0.510)

0.3

29

97.5

... More
GI barbed wire anticlimbing device 3 Kg. Per support

3

312

104

... More
Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 4 no’s = (4x0.59x0.510)

1.2

117

97.5

... More
11 KV pin insulator polymer

3

780

260

... More
H W fitting(B&S) 70KN, 3Bolt

6

2730

455

... More
Disc insulator (B&S) 70 KN polymer

6

8970

1495

... More
Earthing of Support ( Coil Type )

1

215

215.8

... More
No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing

0.3

29

97.5

... More
PG Clamp for 55 sq.mm AAA conductor

6

3744

624

... More
GI Nut , Bolt & Washer of different sizes

3.6

365

101.4

... More
Black Paint

0.5

143

286

... More
Yellow Colour Paint for Background

2

432

216

... More
Stock, Storage & Insurance i.e 3%

1

1509

1509.83

... More
Contigency @ 3%

1

1555

1555.13

... More
Tools & Plants @ 2%

1

1036

1036.75

... More
Transportation @ 7.5%

1

3887

3887.82

... More
Erection Charges @ 5% (on Trf/ Breaker/ Joist)

1

1527

1527.54

... More
Erection Charges @ 10% (except Trf/Breaker/WBP/H-pole/HT stay set/PSC pole)

1

2128

2128.68

... More
Civil & Services Work

-

-

-

... More
Concreting ratio 1:1.5:3 (500mm x 500mmx1800mm ) = 0.45 Cum Mtr

0.5

3250

6500

... More
Concreting ratio 1:1.5:3 (500mm x 500mmx450mm ) = 0.1125 Cum Mtr

0.1

650

6500

... More
Other overheads (Including 6% supervision charges)

1

3937

3937.79

... More
Material for 11 KV Cut Point with 90 degree angle

-

-

-

... More
WBP GI pole 160x152 (11 mtr lomg 30044 kg/Mtr)

1

29661

29661

... More
Straight cross arm 100x50x6mm , 9.56 kg per mtr each channel length 1.2 mtr 4 nos channel required =( 4x9.56x1.2)

45.9

3488

76

... More
Fish plate 50x8mm,2.36 kg/mtr each 0.28 mtr. length 16 nos required= (16x2.36x0.28)

10.6

1033

97.5

... More
Straight cross arm 100x50x6mm , 9.56 kg per mtr each channel length 0.306 mtr 4 nos channel required = (4x9.56x0.306)

11.7

889

76

... More
Danger Ptate, 1 no's.

1

104

104

... More
Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 1 no's = (1x0.59x0.510)

0.3

29

97.5

... More
GI barbed wire anticlimbing device 3 Kg. Per support

3

312

104

... More
Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 4 no’s = (4x0.59x0.510)

1.2

117

97.5

... More
11 KV pin insulator polymer

4

1040

260

... More
H W fitting(B&S) 70KN, 3Bolt

9

4095

455

... More
Disc insulator (B&S) 70 KN polymer

9

13455

1495

... More
Earthing of Support ( Coil Type )

1

215

215.8

... More
No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing

0.3

29

97.5

... More
PG Clamp for 55 sq.mm AAA conductor

9

5616

624

... More
H.T. Stay clamp, 50x8 mm. flat, 3.14Kg/Mtr., 0.551 Mtr. Length, 2 no's qty. required ( 1 Pair)

1

162

162.5

... More
H.T. Stay set (Complete )

1

1365

1365

... More
H.T. Stay Insulator Type-C

1

65

65

... More
7/10 SWG Stay Wire 15kg /stay

15

1462

97.5

... More
GI Nut , Bolt & Washer of different sizes

7.4

750

101.4

... More
Black Paint

0.5

143

286

... More
Yellow Colour Paint for Background

2

432

216

... More
Stock, Storage & Insurance i.e 3%

1

1933

1933.87

... More
Contigency @ 3%

1

1991

1991.89

... More
Tools & Plants @ 2%

1

1264

1264.99

... More
Transportation @ 7.5%

1

4979

4979.72

... More
Erection Charges @ 5% (on Trf/ Breaker/ Joist)

1

1527

1527.54

... More
Erection Charges @ 10% (except Trf/Breaker/WBP/H-pole/HT stay set/PSC pole)

1

3269

3269.88

... More
Civil & Services Work

-

-

-

... More
Fixing of complete 11 KV line complete stay set includes 1) Turn Bucklw Assembly 2) Stay Rod & Stay Plate 3) Stay Insulator 4) Stay Wire 5) Stay clamps with Nuts & Bolts will do the excavation supply of 0.5 cim cement concrete foundation 1:2:4 size 500 mm x 500 mm x 800 mm using 20 mm BHG metal with all labour and material as per TPCODL srawing and standard

1

2250

2250

... More
Concreting ratio 1:1.5:3 (500mm x 500mmx1800mm ) = 0.45 Cum Mtr

0.5

3250

6500

... More
Concreting ratio 1:1.5:3 (500mm x 500mmx450mm ) = 0.1125 Cum Mtr

0.1

650

6500

... More
Other overheads (Including 6% supervision charges)

1

5120

5120.19

... More
Material for 11 KV pin points with 90 Degree Angle

-

-

-

... More
PSC pole 9 mtr lomg 300 kg

1

3900

3900

... More
PSC pole clamp

2

208

104

... More
Straight cross arm 100x50x6mm , 9.56 kg per mtr each channel length 1.2 mtr 4 nos channel required =( 4x9.56x1.2)

45.9

3488

76

... More
Fish plate 50x8mm,2.36 kg/mtr each 0.28 mtr. length 16 nos required= (16x2.36x0.28)

10.6

1033

97.5

... More
Straight cross arm 100x50x6mm , 9.56 kg per mtr each channel length 0.306 mtr 4 nos channel required = (4x9.56x0.306)

11.7

889

76

... More
Danger Ptate, 1 no's.

1

104

104

... More
Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 1 no's = (1x0.59x0.510)

0.3

29

97.5

... More
GI barbed wire anticlimbing device 3 Kg. Per support

3

312

104

... More
Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 4 no’s = (4x0.59x0.510)

1.2

117

97.5

... More
11 KV pin insulator polymer

4

1040

260

... More
H W fitting(B&S) 70KN, 3Bolt

6

2730

455

... More
Disc insulator (B&S) 70 KN polymer

6

8970

1495

... More
Earthing of Support ( Coil Type )

1

215

215.8

... More
No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing

0.3

29

97.5

... More
PG Clamp for 55 sq.mm AAA conductor

6

3744

624

... More
H.T. Stay clamp, 50x8 mm. flat, 3.14Kg/Mtr., 0.551 Mtr. Length, 2 no's qty. required ( 1 Pair)

2

325

162.5

... More
H.T. Stay set (Complete )

2

2730

1365

... More
H.T. Stay Insulator Type-C

2

130

65

... More
7/10 SWG Stay Wire 15kg /stay

30

2925

97.5

... More
GI Nut , Bolt & Washer of different sizes

7.4

750

101.4

... More
Black Paint

0.5

143

286

... More
Yellow Colour Paint for Background

2

432

216

... More
Stock, Storage & Insurance i.e 3%

1

1027

1027.27

... More
Contigency @ 3%

1

1058

1058.09

... More
Tools & Plants @ 2%

1

579

579.53

... More
Transportation @ 7.5%

1

2645

2645.22

... More
Erection Charges @ 10% (except Trf/Breaker/WPB/ H-Pole/HT stay set/PSC pole)

1

2495

2495.94

... More
Erection Charges @ 20% of PSC pole- Not to be used for 33kv

1

803

803.4

... More
Civil & Services Work

-

-

-

... More
Fixing of complete 11 KV line complete stay set includes 1) Turn Bucklw Assembly 2) Stay Rod & Stay Plate 3) Stay Insulator 4) Stay Wire 5) Stay clamps with Nuts & Bolts will do the excavation supply of 0.5 cim cement concrete foundation 1:2:4 size 500 mm x 500 mm x 800 mm using 20 mm BHG metal with all labour and material as per TPCODL srawing and standard

2

4500

2250

... More
Concreting ratio 1:1.5:3 (500mm x 500mmx1500mm ) = 0.375 Cum Mtr

0.4

2600

6500

... More
Other overheads (Including 6% supervision charges) for 11KV cut point with 90 degree angle

1

2987

2987.36

... More
11KV line length 0.20 in KM with 40 mtr. span

-

-

-

... More
Material for 11 KV pin points with PSC

-

-

-

... More
PSC pole 9 mtr lomg 300 kg

2

7800

3900

... More
PSC pole V cross Arm Back clamp

2

208

104

... More
11 KV V cross Arm (10.2 K.g. each )

2

2106

1053

... More
Top bracket 100x50X6 mm GI channel(2Kg each)

2

390

195

... More
Danger Ptate, 1 no's for each pole

2

208

104

... More
Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 1 no's = (1x0.59x0.510)

0.6

58

97.5

... More
GI barbed wire anticlimbing device 3 Kg. Per support

6

624

104

... More
Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 4 no’s = (4x0.59x0.510)

2.4

234

97.5

... More
11 KV pin insulator polymer

6

1560

260

... More
Earthing of Support ( Coil Type )

2

431

215.8

... More
No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing

0.5

48

97.5

... More
GI Nut , Bolt & Washer of different sizes

2.9

294

101.4

... More
55 mm2 AAAC

0.6

23400

39000

... More
Black Paint

2

572

286

... More
Yellow Colour Paint for Background

4

864

216

... More
Stock, Storage & Insurance i.e 3%

1

1185

1185.12

... More
Contigency @ 3%

1

1220

1220.68

... More
Tools & Plants @ 2%

1

813

813.79

... More
Transportation @ 7.5%

1

3051

3051.69

... More
Erection Charges @ 10% (except Trf/Breaker/WPB/ H-Pole/HT stay set/PSC pole)

1

3265

3265.53

... More
Erection Charges @ 20% of PSC pole- Not to be used for 33kv

1

1606

1606.8

... More
Civil & Services Work

-

-

-

... More
Concreting ratio 1:1.5:3 (500mm x 500mmx1500mm ) = 0.375 Cum Mtr

0.8

5200

6500

... More
Other overheads (Including 6% supervision charges) for 11KV cut point with 90 degree angle

1

3331

3331.36

... More
Line Protecting Guarding on Single Pole for Road Crossing

-

-

-

... More
Length of 11 KV Line Protecting Guarding = 30 Mtr

-

-

-

... More
Material for Line Protecting guarding

-

-

-

... More
Grading channel 75x40x6 mm , 7.14 kg/mtr each channel length 2.2 mtr, 4 nos channel required = 4x7.14x2.2 (For single pole)

62.8

4772

76

... More
No-6 GI Wire (0.192 kg/mtr) for main string

23

2242

97.5

... More
No-8 GI Wire (0.131 kg/mtr ) for lacing

4.9

477

97.5

... More
Eye Bolt (136 mm , 16 mm dia 1.577 kg/mtr)

4

312

78

... More
GI pipe earthing 40 mm, 3 Mtr long

2

2730

1365

... More
50x6 mm GI Flat for earthing, 2.36 kg/mtr (107 mtr for raising) = 10.7x2.36

50.5

4923

97.5

... More
Stock, Storage & Insurance i.e 3%

1

464

464

... More
Contigency @ 3%

1

477

477.92

... More
Tools & Plants @ 2%

1

262

262.38

... More
Transportation @ 7.5%

1

1194

1194.81

... More
Erection Charges @ 10% (except Trf/Breaker/WPB/ H-Pole/HT stay set/PSC pole)

1

1311

1311.88

... More
Civil & Services Work

-

-

-

... More
Construction earthing chamber including installation of earthing pipe making earthing chamber including excavation, soil treatment with bentonite powder calculation of earth resistance including installation of 3 Mtr GI pipe 40mm/50mm including welding of GI flat around pipe

2

7400

3700

... More
Other overheads (Including 6% supervision charges) for 11KV cut point with 90 degree angle

1

1594

1594.66

... More
Material for DP Mounted DSS

-

-

-

... More
9 Mtr. long 300 Kg. PSC Pole (For DSS DP)

2

7800

3900

... More
Pole clamp

14

1456

104

... More
Top Channel 100 x 50 x 6mm MS channel each 3.0 mtr. Long( 9.56 K.g. per mtr.) x2 nos

57.4

4362

76

... More
Fish Plate 50 x 6 mm MS Angel (0.28 mtrs. Long 6 nos.)2.36K.g. per mtr.

4

390

97.5

... More
AB Swith Mounting Channel 75x40x6 -3.0 mtr.long, 2 nos.(14K.g. per mtr.)

42.8

3252

76

... More
AB Swith side support Channel 100x50x6 -0.35 mtr.long, 2 nos.(9.56K.g. per mtr.)

6.7

509

76

... More
Channel support for down pipe 75x40x6 -0.8 mtr.long, 1 nos.(7.14K.g. per mtr.)

5.7

433

76

... More
HG/DD Fuse, Mounting Channel 75x40x8 -3.0 mtr.long, 2 nos.(7.14K.g. per mtr.)

42.8

3252

76

... More
Cantilever support chhanel 75 x 40 x 8 mm GI chhanel (0.81 mtrs. Long 2 nos.)7.14K.g. per mtr.

11.6

881

76

... More
Angle for Cantilever arrrangement for AB Switch & HG Fuse 50 x 50 x 6 -2 mtr .each 2 nos.(4.5 K.g. per mtr.)

11.5

874

76

... More
Transformer base GI chhanel 100 x 50 x 6mm GI channel each 3.0 mtr. Long( 9.56 K.g. per mtr.)x2 nos

57.4

4362

76

... More
Transformer base support GI chhanel 100 x 50 x 6mm GI channel each 0.515 mtr. Long( 9.56 K.g. per mtr.)x2 nos

9.9

752

76

... More
Transformer belting Angel 50 x 50 x 6 mm - 3.0 mtr. Long 2 nos.(4.5 K.g. per mtr.)

27

2052

76

... More
Transformer beltingsupport Angel 50 x 50 x 6 mm - 0.58 mtr. Long 2 nos.(4.5 K.g. per mtr.)

5.2

395

76

... More
LTDB mounting ANGLE 50 x 50 x 6mm GI each 1.0 mtr. Long( 4.5 K.g. per mtr.)x2 nos

9

684

76

... More
50X6 mm GI Flat for earthisng 2.36 kg/mtr (2.5x7 mtr) for mesh formation 12 Mtr for LA and 2.5 Mtr for raising, 11 Mtr for AB switch, 2.8 Mtr fro HG fuse, 5x2 mtr for DTR Neutral (1.3+4.5)mtr for DTR body 0.5 Mtr for LTDB & AB switch operating handle, 3 mtr for fencing

154.8

15093

97.5

... More
25KVA, 11/0.4KV (AL) Transformer BIS energy Level-II

1

69940

69940

... More
L.T. Distribution box with MCCB, Aluminum Busbar of single Bay with kit kat fuse for 25KVA S/S

1

19409

19409

... More
55 mm2 AAAC PVC insulated

50

2762

55.24

... More
4c x 35mm2 LT XLPE Cable(Armoured) for 25 KVA TFR.

15

3200

213.38

... More
AB Switch (11KV, 200A. 3 Pole 50 Hz )

1

9555

9555

... More
HG Fuse (11KV, 200A.3 pole)

1

7956

7956

... More
PG clamp ofr 55 sq mm AAA conductor

6

3744

624

... More
DISC Insulator (B & S) 70KN Polymer

3

4485

1495

... More
H.W. Fitting (B & S ) 70 KN 3 Bolt

3

1365

455

... More
Lightning Arrestor (12 KV . 10 KA) Station Class 2

3

13845

4615

... More
11 KV Pin Insulator Polymer

3

780

260

... More
H.T. Stay set (Complete )

2

2730

1365

... More
H.T. Stay clamp (1.95 K.g./ Pair )

2

325

162.5

... More
H.T. Stay Insulator TYPE-C

2

130

65

... More
7/10 SWG GI Stay Wire Grade-2 (15 kg / Stay)

30

2925

97.5

... More
40mm nominal bore GI pipe (medium gauge) earthing device with 3 mtr. Long

7

9555

1365

... More
GI Nuts & Bolts of Assorted size

25

2535

101.4

... More
GI barbed wire anticlimbing device 3 Kg. Per support

6

624

104

... More
Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 4 no’s = (4x0.59x0.510)

2.4

234

97.5

... More
Danger plate (11 KV)

2

208

104

... More
Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 1 no's — (1x0.59x0.510)

0.6

58

97.5

... More
Name Plate

1

104

104

... More
Structure Numbering and Marking

-

-

-

... More
Yellow Colour Paint for Background

2

432

216

... More
Black colour Paint for Numbering

1

286

286

... More
Stock, Storage & Insurance i.e 3%

1

6112

6112.09

... More
Contigency @ 3%

1

6295

6295.45

... More
Tools & Plants @ 2%

1

3608

3608.34

... More
Transportation @ 7.5%

1

15738

15738.63

... More
Erection Charges @ 5% on Trf/Breaker/Joist

1

3601

3601.91

... More
Erection Charges @ 10% (except Trf/Breaker/WPB/ H-Pole/HT stay set/PSC pole)

1

11034

11034.45

... More
Erection Charges @ 20% of PSC pole- Not to be used for 33kv

1

1606

1606.8

... More
Civil & Services Work

-

-

-

... More
Concreting ratio 1:1.5:3 (500mm x 500mmx1500mm ) = 0.375 Cum Mtr

0.8

5200

6500

... More
Fixing of stay set with 0.5Cum cement concret foundation 1:3:6 size ( 900mmx600mmx900mm) using 40mm BHG metal with all labour and material except stay set , stay wire , stay insulator .

2

4500

2250

... More
Construction earthing chamber including installation of earthing pipe making earthing chamber including excavation, soil treatment with bentonite powder calculation of earth resistance including installation of 3 Mtr GI pipe 40mm/50mm including welding of GI flat around pipe

7

25900

3700

... More
Laying of 4C x 35 mm2 LT XLPE cable

15

702

46.8

... More
Supply and errection of GI fencing with gate

15

54000

3600

... More
Other overheads (Including 6% supervision charges) for 11KV cut point with 90 degree angle

1

20514

20514.66

... More
Material for Service Connection

-

-

-

... More
4C x 10 mm2 Armoured Aluminium Cable LT XLPE

10

1003

100.33

... More
Insulated piercing connector, Type-B main 16 to 95 sq mm & Tap-1.5 to 16 sqmm - For LT AB Cable

4

240

60

... More
GI Nuts & Bolts and washer

0.3

30

101.4

... More
Applicable Taxes to make in landed cost @ 18%

1

228

228.36

... More
Stock, Storage & Insurance i.e 3%

1

44

44.91

... More
Contigency @ 3%

1

46

46.26

... More
Tools & Plants @ 2%

1

30

30.84

... More
Transportation @ 7.5%

1

115

115.64

... More
Erection Charges @ 10% (except Trf/Breaker/WPB/ H-Pole/HT stay set/PSC pole)

1

154

154.19

... More
Civil & Services

-

-

-

... More
Other overheads (Including 6% supervision charges) for 11KV cut point with 90 degree angle

1

113

113.35



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.