Rural Development Department Tender

Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.

Rural Development Department - RDD Tender

Works
Building Construction
Eprocure
Opening Date21 Jan 2025
Closing Date7 Feb 2025
Tender Amount₹ 18,55,24,748 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Ground Floor

505.74

-

-

... More
Providing 375mm dia and 8.00 m long, single under reamed bored compaction cast-in-situ RCC Pile with M-25 grade concrete including cost of boring to required dia meter and depth to plumb and taking precautionary measure against collapsing of side soil due to presence of water table using bentonite powder etc., concreting and driving the cage made of M.S. / T.S. steel as per approved drawing into the freshly laid concrete vertically by means of power winch to requied depth but excluding cost of M.S. / T.S. steel and labour charges for cutting, bending and binding of steel etc. complete confirming to IS-2911 specification including necessary routine tests including cost, conveyance, royalties and taxes of all materials with labour,labour cess and T&P etc. required for the work complete as per the specification and instruction of Engineer-in-Charge.

-

-

-

... More
Ground Floor

2704

-

-

... More
Supplying and filling in foundation and plinth with good quality river sand including watering, ramming with cost, conveyances, royalties of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer-in-charge.

-

-

-

... More
Ground Floor

740.94

-

-

... More
Diluting and injecting chemical emulsion (to be supplied free of cost at site of work) for PRE CONSTRUCTIONAL Anti-termite treatment and creating a continuous chemical barrier under and all-round the column pits, wall trenches, basement excavation, top perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surroundings of pipes and conduits etc. complete as per specifications (plinth area of the building at ground floor only shall be measured for payment).

-

-

-

... More
Ground Floor

855

-

-

... More
Cement concrete of proportion (1:4:8) in foundation and floors using 4cm size clean hard black crusher broken granite stone metal of approved quality and from approved quarry including hoisting, lowering and laying concrete in layers not exceeding 15 cm. (6") thick to the required level ramming, watering, curing etc. complete including cost, conveyance, royalties of all materials with all labour and T&P required for the work etc. complete in all respect and as per the direction of the Engineer-in-charge.

-

-

-

... More
Ground Floor

65.81

-

-

... More
Providing and laying plain cement concrete of proportion (1:3:6) in foundation and floors using 4 cm. size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality and from approved quarry including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm. thick in each layer including cost, conveyance, royalties of all materials and cost of all labours,labour cess, T&P etc complete as per the direction of the Engineer-in-charge.

-

-

-

... More
Ground Floor

84.68

-

-

... More
Fly Ash brick masonry in cement mortar (1:6) in foundation & plinth using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge.

-

-

-

... More
Ground Floor

56.79

-

-

... More
Fly Ash brick masonry in cement mortar (1:6) in super structure using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge.

-

-

-

... More
Ground Floor

163.24

-

-

... More
First Floor

121.38

-

-

... More
Second Floor

151.99

-

-

... More
Third Floor

154.37

-

-

... More
Fourth Floor

154.37

-

-

... More
Terrace Floor

62.4

-

-

... More
Fly Ash brick masonry in cement mortar (1:4) in super structure using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge.

-

-

-

... More
Ground Floor

20

-

-

... More
First Floor

29.61

-

-

... More
Second Floor

29.49

-

-

... More
Third Floor

12.3

-

-

... More
Fourth Floor

12.3

-

-

... More
Providing and Fixing 100 mm thick dry wall with impact resistance board and 2 hrs fire rating, 4" EPS modular wall pannels partition. The eps construction system shall be of modular pannels and accessories to build a frame for a structure of Width 1200 mm, length 200 6000mm Eps slab thickness 100mm Eps slab type plain or corrugated with mesh of 50x 50 mm,100x100 mm having Mesh wire of thickness 2.5 mm dia (std)2.0mm,3.0 mm. (Thickness details 2.5 mm wire 50x50 mm mesh 50 mm easy pannels with 1" plaster both side) having Self load 120 kg/ m2, load bearing 350kn/m. th mal insulation k value of 0.033, good water proof, good Sound proof, good Strength weight ratio with Load bearing and 120 min.of fire rated, with thermal insulation, sound insolation, monolithic & strong, earth quake resistance, no corrosion, mep conduitng, curved pannels, easy installation of electrical and plumbing service, pest resistance, having plaster cracks, no mounds, for fast construction, light weight & economic green building products having Eps density of 15 kg/ m3 including cost of all materials, labour, T&P, royalty etc complete in all respect and as per direction of the Engineer-in- charge.

-

-

-

... More
Ground Floor

152.84

-

-

... More
First Floor

190.69

-

-

... More
Second Floor

152.09

-

-

... More
Third Floor

280.44

-

-

... More
Fourth Floor

280.44

-

-

... More
Providing, lifting, hoisting and laying Reinforced cement concrete of M-25 grade as per approved designs and drawings having a minimum compressive strength (in work test) 250 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portland slag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position.

-

-

-

... More
Pile cap

-

-

-

... More
Ground Floor

458.4

-

-

... More
RCC wall up to NGL

-

-

-

... More
Ground Floor

14.03

-

-

... More
COLUMN ABOVE PLINTH

-

-

-

... More
Ground Floor

127.63

-

-

... More
First Floor

76.32

-

-

... More
Second Floor

75.53

-

-

... More
Third Floor

74.77

-

-

... More
Fourth Floor

74.52

-

-

... More
Terrace Floor

12.34

-

-

... More
PLINTH BEAM

-

-

-

... More
Ground Floor

55.03

-

-

... More
LINTEL

-

-

-

... More
Ground Floor

10.18

-

-

... More
First Floor

8.99

-

-

... More
Second Floor

10.71

-

-

... More
Third Floor

8.45

-

-

... More
Fourth Floor

8.45

-

-

... More
Terrace Floor

1.64

-

-

... More
CHAJJA & FINS

-

-

-

... More
Ground Floor

43.61

-

-

... More
First Floor

19.86

-

-

... More
Second Floor

19.86

-

-

... More
Third Floor

19.86

-

-

... More
Fourth Floor

19.86

-

-

... More
Terrace Floor

4.23

-

-

... More
ROOF BEAM

-

-

-

... More
Ground Floor

94.16

-

-

... More
First Floor

95.96

-

-

... More
Second Floor

91.04

-

-

... More
Third Floor

91.29

-

-

... More
Fourth Floor

91.29

-

-

... More
Terrace Floor

14.01

-

-

... More
ROOF SLAB

-

-

-

... More
Ground Floor

121.87

-

-

... More
First Floor

121.79

-

-

... More
Second Floor

104.77

-

-

... More
Third Floor

104.77

-

-

... More
Fourth Floor

104.77

-

-

... More
Terrace Floor

17.57

-

-

... More
STAIRCASE

-

-

-

... More
Ground Floor

10.21

-

-

... More
First Floor

10.19

-

-

... More
Second Floor

10.23

-

-

... More
Third Floor

10.23

-

-

... More
Fourth Floor

10.23

-

-

... More
Supplying Cutting, straightening coiled or bent up M.S. Rod or tor steel of primary steel producers such as SAIL / Tiscon / RINL / JINDAL STEEL / SHYAM STEEL (grade Fe-500D) etc. including bending, binding, welding, wastage & over lapping and jointing if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors with labour cess etc. (payment will be made on standard weight of B.I.S. for M.S. Rods or tor steel only) etc. complete as per specification & direction of Engineer-in-charge.

-

-

-

... More
Ground Floor

1537.45

-

-

... More
First Floor

499.68

-

-

... More
Second Floor

474.32

-

-

... More
Third Floor

470.48

-

-

... More
Fourth Floor

469.98

-

-

... More
Terrace Floor

67.61

-

-

... More
Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.

-

-

-

... More
Ground Floor

485.66

-

-

... More
First Floor

482.57

-

-

... More
Second Floor

530.7

-

-

... More
Third Floor

580.22

-

-

... More
Fourth Floor

581.48

-

-

... More
Terrace Floor

445.38

-

-

... More
Providing 16 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.

-

-

-

... More
Ground Floor

1684.3

-

-

... More
First Floor

1652.28

-

-

... More
Second Floor

1693.61

-

-

... More
Third Floor

2302.19

-

-

... More
Fourth Floor

2300.39

-

-

... More
Terrace Floor

147.78

-

-

... More
Providing 6 mm thick cement plaster with cement mortar of mix (1:4) with screened and washed sharp sand for mortar and finished smooth to R.C.C. work after closed deep chipping & slurry treatment including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.

-

-

-

... More
Terrace Floor

94.03

-

-

... More
Fixing granite tiles of approved dimension area above 0.4 sqm (20mm thick) in floor, treads of steps and landing on 20mm thick bed of cement mortar (1:4) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties of all materials complete in all respects as per direction of Engineer-in-Charge.

-

-

-

... More
Ground Floor

165.36

-

-

... More
First Floor

196.58

-

-

... More
Second Floor

121.48

-

-

... More
Third Floor

173.35

-

-

... More
Fourth Floor

173.35

-

-

... More
Supplying, fitting and fixing Glazed vetrified tiles (GVT) of premium grade having thickness 10mm confirming to IS of size 600mm x 1200mm Plain (Ivory)of approved make (JOHNSON / KAJARIA/ RAK) in floors on 20mm thick bed of C.M. (1:4)(1cement:4course sand) and filling the joint with white cement mixed with pigment to match the shades of the tileincluding cost of all materials, labour, labour cess, T&P etc. required for the work complete in all respect as directed by the Engineer in charge.

-

-

-

... More
Ground Floor

529.05

-

-

... More
First Floor

266.58

-

-

... More
Second Floor

174.31

-

-

... More
Third Floor

378.58

-

-

... More
Fourth Floor

378.58

-

-

... More
Providing, fitting, fixing Glazed vetrified tiles (GVT) of premium grade having thickness 8mm to 10mm confirming to IS of size 600mm x 1200mm Color / Printed series (Homogenous) of approved make (JOHNSON/ KAJARIA/ RAK) as directed by Engineer-in-charge in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties of all materials all labour,labour cess complete in all respects.

-

-

-

... More
Ground Floor

59.25

-

-

... More
First Floor

23.82

-

-

... More
Second Floor

16.79

-

-

... More
Third Floor

20.27

-

-

... More
Fourth Floor

20.27

-

-

... More
Supplying, fitting and fixing vetrified Industrial tiles in floors of premium grade having thickness10mm of size 400mm x 400mm confirming to IS with colour / printed series of approved make (JOHNSON /RAK / KAJARIA) on 20mm thick bed of C.M. (1:4) including cost of all materials, labour, T&P etc. required for the work in all respect as directed by the Engineer in charge.

-

-

-

... More
Ground Floor

22.32

-

-

... More
Supplying, fitting and fixing vetrified Industrial tiles in floors of premium grade having thickness 10mm of size 300mm x 300mm confirming to IS with colour / printed series of approved make (JOHNSON /RAK / KAJARIA or equivalent ) on 20mm thick bed of C.M. (1:4) including cost of all materials, labour, T&P etc. required for the work in all respect as directed by the Engineer in charge.

-

-

-

... More
Ground Floor

190.57

-

-

... More
First Floor

170

-

-

... More
Second Floor

170

-

-

... More
Third Floor

170

-

-

... More
Fourth Floor

170

-

-

... More
Providing and laying Platform jalsalmer & Tactile jalsalmer 15mm thickness, siz-300x300 mm 1st quality of RAK, JOHNSON, KAJARIA or equivalent approved make, colours & shades laid on 20 mm thick cement mortar 1:4 (1cement: 4coarse sand) including pointing the joints with white cement and matching pigments, etc. complete as per direction of EIC at all floors and all heights.

-

-

-

... More
Ground Floor

27.68

-

-

... More
First Floor

23.58

-

-

... More
Second Floor

23.58

-

-

... More
Third Floor

23.58

-

-

... More
Fourth Floor

23.58

-

-

... More
Providing full body matt finish vitrified tile flooring using vitrified tiles having thickness of min 10mm conforming to IS 13755 of 1200x600 (homogeneous) of premium quality (JOHNSON / SOMANY/ KAJARIA/ RAK) in floors, treads on steps and landings on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and fixing with neat white cement slurry,grouting the joints with neat white cement slurry mixed with required quantities of pigments of approved make to match the shades of the vitrified tile if required , watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour,Labour cess , sundries, T&P required for the work, complete in all respect as per specification and direction of Engineer-in-charge.

-

-

-

... More
Ground Floor

154.05

-

-

... More
First Floor

312.74

-

-

... More
Second Floor

250.37

-

-

... More
Third Floor

152.47

-

-

... More
Fourth Floor

152.47

-

-

... More
Fixing of Ceramic wall tiles of premium grade having thickness 6.50mm to 7.00mm confirming to IS 13753 of size 60cm x 30cm special plain / printed series in dados skirting & riser of steps on 12mm thick cement plaster 1:3 joined with neat cement slurry mixed with pigments to match the shade of the tiles, including rubbing & polishing etc. complete including cost, conveyance, royalties of all materials, labour with T&P complete in all respects as per direction of Engineer-in-Charge. (make-Somany,Johnson,RAK,Kajaria)

-

-

-

... More
Ground Floor

218.04

-

-

... More
First Floor

268.25

-

-

... More
Second Floor

228.2

-

-

... More
Third Floor

147.48

-

-

... More
Fourth Floor

171.48

-

-

... More
Fixing of Kota Stone of minium thickness 16mm thick of premium grade of size above 0.10 Sqm. in floors over 20mm thick bed of cement mortar 1:4 (1cement:4course sand)and filling the joint with white cement mixed with pigments to match the shade of the tiles, including rubbing & polishing etc. complete including cost, conveyance, royalties of all materials, labour,labour cess with T&P complete in all respects as per direction of Engineer-in-Charge.

-

-

-

... More
Ground Floor

28.31

-

-

... More
First Floor

23.2

-

-

... More
Second Floor

36.65

-

-

... More
Third Floor

63.54

-

-

... More
Fourth Floor

63.54

-

-

... More
LABORATORY-FLOORING :- Providing and installation of Standard Plus anti bacterial PVC Flooring with 3mm cementious self-leveling flooring system with CL 11 as per specification of Ardex Endura. PVC flooring manufactured by Tarkett with a nominal thickness of 2mm as per ISO 24346 - EN 428. The nominal thickness of the wear layer shall be 2mm. The wear suface shall be PUR reinforced. Standard Plus shall conform to requirement of ISO 10581 - EN 649. It shall have blinder content of Type I as per ISO 10581, Fire resistance of 8kW/m2 as per ISO 9239-1 and class Bfl-S1 as per EN 13501-1, Indentation of less than .04mm as per ISO 24343-1 and EN 433, Slip Resistance of R9 as per DIN 51130, greater than 0.3 as per EN 13893. The static electrical discharge shall be less than 2kV as per EN 1815. Eclipse Premium shall have Class A as per ASTM F24 F51 for the clean room test. The product does not contain Pthalate based plasticizer and emission rate of VOC is very low, measured after 28 days as per EN 16516. TVOC and formaldehyde emissions are below 10 g/m3. It is 100% REACH compliant. The product is fit to be used in Class 34 in commercial and Class 43 in industrial as per EN ISO 10874. The product is installed using welding rods to ensure seamless finish. The average seam strength shall be more than 240N/50mm as per EN 684.

-

-

-

... More
Ground Floor

25.54

-

-

... More
Second Floor

19.97

-

-

... More
Third Floor

16.33

-

-

... More
Fourth Floor

16.33

-

-

... More
OT, ICU :- Providing and installation of Primo SD anti bacterial PVC antistatic Flooring with 3mm cementious self-levelling flooring system with CL 11 as per specification of Ardex Endura. PVC flooring manufactured by Tarkett with a norminaql thickness of 2mm as per ISO 24340-EN 649. Primo SD shall have blinder content of Type I as per ISO 10581, Fire resistance of 8kW/m2 as per ISO 9239-1 and class Bfl-S1 as per EN 13501-1, Indentation of less than .03mm as per ISO 24343-1 and EN 433, Sip Resistance of R9 as per DIN 51130, GREATER THAN 0.3 AS PER EN 13893. The static electrical discharge shall be less than 2kV as per EN 1815. The electrical resistance of the product shall be less than 10^8 as per N 1081. The product does not contain Pthalate based plasticizer and emission rate of VOC is very low, measered after 28 days as per EN 16516. TVOC and formaldehyde emissions are below 10 g/m3. It is 100% REACH compliant. The product is fit to be used in Class 34 in Industrial as per EN ISO 10874. The product is installed using multi coloured welding rods to ensure seamless finish. The average seam strength shall be more than 240N/50mm as per EN 684.

-

-

-

... More
Second Floor

181.8

-

-

... More
WALLGARD FOR OT & ICU. Providing and installation of Homogenous Vinyl Sheet for wall with a total thickness of 1.3 mm as per ISO 24346 - EN 428, width of 2m as per ISO 24341 - EN 426, weight of 2.100 g/m2 as per EN ISO 23997.. The wear surface shall be PUR reinforced. It shall conform to requirement of wetroom as per GBR class VT. It shall have Class A as per ASTM F24 F51 and ISO Class 4 as per ISO 14644-1 for the Clean room test. he product does not contain Pthalate based plasticizer and emission rate of VOC is very low, measured after 28 days as per EN 16516. TVOC and formaldehyde emissions are below 10µg/m3. It is 100% REACH compliant. The product is fit to be used in Class 34 in Commercial and Class 43 in Industrial as per EN ISO 10874. The product is installed using multi coloured welding rods to ensure seamless finish. The average seam strength shall be more than 240N/50mm as per EN 684.

-

-

-

... More
Second Floor

271.01

-

-

... More
Supplying, fitting and fixing of openable UPVC doors with door frame of approved make with 6mm thick glass of apprved make (FENESTA/NCL VEKA LTD./Koemmerling/ DURAPLAST) quality complete with frame, shutters and all fittings and fixtures including all cost,conveyance,royalty & taxes of all materials,labour,T&P required for the work etc. complete as per specification & direction of the Engineer-in-charge.

-

-

-

... More
First Floor

25.2

-

-

... More
Second Floor

25.2

-

-

... More
Third Floor

79.2

-

-

... More
Fourth Floor

22.8

-

-

... More
Supply & installation of Lead lined door. Door leaves construced from 1.20mm thick Glavanized steel sheet formed to provide a 46mm thick Galvanized steel sheet formed to provide a 46mm thick fully flush, double skin door shell with lock seam joints at stile edges. In fill of PUF including 2.0mm lead sheet (Poly Urethanes Foam) is used to give the required rigidity and effective acoustic and thermal insulation. Door frames produced from 1.6mm thick galvanized steel sheet formed to double or single rebate profile of size 143x57105mmx60mm & 100x57 mm and we are insertb 2mm lead sheet in the door frame. The door frames may be built into the brick or block walls using corrugated "T" anchors not welded to the frames (First fix). Frames may also be fixed on plastered openings with the hepl of Anchor fasteners ( Second fix). Door frames are supplied to knock down from with butt joints for bolted assembly at site, including cost of materials, all labour,sundries,T& P etc.complete in all respect as per direction of Engineer-in-charge.

-

-

-

... More
Ground Floor

69.48

-

-

... More
First Floor

63.72

-

-

... More
Second Floor

63.72

-

-

... More
Third Floor

67.8

-

-

... More
Fourth Floor

67.8

-

-

... More
Supplying and installing UPVC-3 tracks sliding windows and 2 sashes (shutters) with ss mesh sash dimension of 58mm x 32mm and sash dimension of 61mm x 37mm for windows with corners fusion welded , fully reinforced with Glavanized steel of 1.2mm to 2mm. The sash will be fitted with 5 mm reflective toughened glass of make-Saint gobin/AIS/Golplus. The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets, bridging wdeges and glass packers) and with suitable water draining system. Application of silicon sealant from inside/outside of Dowcornig / GE or equivalent including cost of all materials, all labour , sundries, T&P etc. complete in all respect as per approved drawing & direction of Engineer-in-charge. (Make:-FENESTA/NCL VEKA LTD./Koemmerling/ DURAPLAST)

-

-

-

... More
Ground Floor

47.28

-

-

... More
First Floor

100.03

-

-

... More
Second Floor

100.03

-

-

... More
Third Floor

69.54

-

-

... More
Fourth Floor

71.34

-

-

... More
Terrace Floor

6.6

-

-

... More
Providing and fixing of Glazed fire door for 120mins fire rating Glazed door shall be tested as per IS/ISO 3009-1, IS 16947 for 120mins fire rating. Door frames and partitions shall be single rebate frame profile of size 125x60mm made out of 1.60mm GI (120 gsm). Door leaf shall be fully glazed with minimum 60 x 120mm profile step box section for taking glass elements. Door leaf shall be manufactured from 1.2mm Gl (120GSM), Doors shall be 60mm thick and the internal construction of the door should be rigid reinforcement pads for stability of profile. For doors and partitions, beeding shall be minimum 1.2 mm Gl with 25mm height, with screws 6 x 19mm. The infill material shall be resin bonded honycomb for rigidity. The glass shall be, ultra clear fire rated glass E120 minimum 8mm thick, for (E) 120 minutes integrity with light transmission of minimum 92% as per EN1363 and EN1364. Glass shall have a impact resistance of 181 as per EN 12600, Glazing kit to be provided along with steel beeding and ceramic tape. Doorset shall include following hardware and accessories as a complete assembly. SS ball bearing hinges of SS304 grade of size 100x75x3mm, Fire rated mortise dead lock, 55mm BS, 20mm sq. forend, including escutheion, with both side key cylinder, 1pairs Pull handle D type, 22dia, CTC 300mm, back to back, with spindle, SS 304, SSS finish. Door closer with spring size of EN 2-4, as per EN1154 and CE marked. Doorset finished in desired colour of powder coating not less than 50microns including suitable anchors all inclusive far fixing of doorset. Rate shall include supply and installation of frame, shutter as a complete assembly including all hardware, & glass with tape.Manufacturer test certificates shall covers complete door set as a un-latched assembly with a valid test certificate not exceeding 5 years from the date of issue of report. for more info refer doors details drawings.

-

-

-

... More
Ground Floor

15.12

-

-

... More
First Floor

10.08

-

-

... More
Second Floor

15.12

-

-

... More
Third Floor

25.2

-

-

... More
Fourth Floor

25.2

-

-

... More
METAL FIRE DOOR :- Providing and fixing ISI Marked un-insulated fire rated door confirming to IS 3614: 2021, & tested to IS17518, and shall carry a shall be for 120minutes integrity only. Material shall be galvanised steel conforming to IS 277, made out of minimum 1.2 (18 SWG) for both frame and shutter, G.l. sheet (zinc coating 120 gsm/sqm). Frame shall be 125 x 55 grooved profile with built in rebate for fire rated smoke seal. Frame shall be mitered and field assembled. EPDM smoke seal to be provided along with frame as standard. Door shutter shall be double skin of 46mm thick with required fire rating and with vision panel. The infill material shall be resin bonded honeycomb core. All doorset shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks and door closers. The door stiles should be interlocked, for pairs of doors integral astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite, minimum 5mm clear fire rated glass of size 150 x 750mm (max 0.12sq.mt) on both shutters, fixing with clipon arrangement. All frame and door shutter shall be finished polyster powder coated to minimum 50microns, of approved colour as per the direction of the engineer incharge Cost of double leaf doorset shall include following hardware and acressories as a complete assembly.

-

-

-

... More
SS ball bearing hinges of 55304 grade of size 100x75x3mm, 1no Fire rated mortise dead lock, 55mm BS, 20mm sq. forend, including escutheion, sss as per EN 12209 with both side key cylinder on active leaf and 2nos flush bolt on the inactive leaf in case of double leaf door along with dust proof socket at bottom, 1pairs Pull handle D type, 22dia, CTC 300mm, back toback per leaf, with spindle, SS 304, SS finish. 1no of Door closer with spring size of EN 2-4, as per EN1154 and CE marked per leaf. Suitable anchor fastners for fixing on different type of wall construction as per manufacturer recommendation. Once frames is installed it shall be filled with fire rated PUF. Manufacturer test certificates shall covers complete door set as a un-latched assembly with a valid test certificate not exceeding 5 years from the date of issue of report.for more info refer doors details drawings, including cost of all materials, all labour, sundries, T&P etc. complete in all respect as per direction of Engineer-in-Charge.

-

-

-

... More
Ground Floor

6.48

-

-

... More
First Floor

6.48

-

-

... More
Second Floor

6.48

-

-

... More
Third Floor

6.48

-

-

... More
Fourth Floor

6.48

-

-

... More
Supplying, fitting & fixing in all floors of M.S. grills, grill gates, M.S. gates, garage door, collapsible gates with top and bottom rails, steel windows, critical frames for windows, stair case and parapet railing made out of M.S Square bar/ flat including stair case hand railing with 40mm. dia G.I.pipe etc. including painting two coats over a coat of redoxide primer as per approved drawing and design with cost of all materials & labour, labour cess, T&P, sundries etc. complete in all respect as per specification & direction of the Engineer-in-Charge.

-

-

-

... More
Ground Floor

3904.5

-

-

... More
First Floor

2500.52

-

-

... More
Second Floor

2500.51

-

-

... More
Third Floor

1769.8

-

-

... More
Fourth Floor

1783.3

-

-

... More
Terrace Floor

401.25

-

-

... More
Priming one coat with wall cement primer (water bound) to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess T&P etc. complete as per the direction of the Engineer-in-charge. (Make: Asian/ Berger/ ICI or equivalent make duly approved by Engineer-in-Charge)

-

-

-

... More
Ground Floor

2169.96

-

-

... More
First Floor

2134.85

-

-

... More
Second Floor

2224.31

-

-

... More
Third Floor

2882.41

-

-

... More
Fourth Floor

2881.87

-

-

... More
Terrace Floor

687.19

-

-

... More
Providing and applying to Wall painting two coats with Anti-Fungal Weather coat paint (1st quality) exterior grade of approved make & approved shade over a coat of primer to make an even finished surface in all floors and heights with all scaffolding and staging charges including cost, conveyance, cost of all labours, T & P, sundries etc. as required for the work complete in all respect as per the direction of the Engineer-in-Charge. (Make: Asian/ Berger/ ICI or equivalent make duly approved by Engineer-in-Charge).

-

-

-

... More
Ground Floor

485.66

-

-

... More
First Floor

482.57

-

-

... More
Second Floor

530.7

-

-

... More
Third Floor

580.22

-

-

... More
Fourth Floor

581.48

-

-

... More
Terrace Floor

445.38

-

-

... More
Finishing plastered surfaces of walls with cement based wall putty (Water based) of approved make (JK White/ Birla white or equivalent make duly approved by Engineer-in-Charge) and finishing the surface smooth and even by sand papering to receive painting in walls, at all heights with staging wherever necessary with cost, conveyance, cost of all labour,labourcess, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-charge.

-

-

-

... More
Ground Floor

1684.3

-

-

... More
First Floor

1652.28

-

-

... More
Second Floor

1693.61

-

-

... More
Third Floor

2302.19

-

-

... More
Fourth Floor

2300.39

-

-

... More
Terrace Floor

241.81

-

-

... More
Painting two coats with Plastic Emulsion paint over a coat of water bond cement primer to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess, T&P etc. complete as per the direction of the Engineer-in-charge. (Make: Asian/ Berger/ ICI/ equivalent make)

-

-

-

... More
Ground Floor

1684.3

-

-

... More
First Floor

1652.28

-

-

... More
Second Floor

1693.61

-

-

... More
Third Floor

2302.19

-

-

... More
Fourth Floor

2300.39

-

-

... More
Terrace Floor

241.81

-

-

... More
Painting two coat with approved synthetic enamel paint to new wood & Iron work over a coat of Red oxide primer including cost, conveyances, royalties of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer in charge. (Make-Asian/ Berger/ ICI or equivalent make duly approved by Engineer-in-charge).

-

-

-

... More
Ground Floor

84.39

-

-

... More
First Floor

50.03

-

-

... More
Second Floor

50.03

-

-

... More
Third Floor

35.39

-

-

... More
Fourth Floor

35.66

-

-

... More
Terrace Floor

26.16

-

-

... More
Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, cost of all labour,labour cess, T&P etc. required for the work complete in all respect as per direction of the Engineer-in-charge. (Make-JINDAL )

-

-

-

... More
Ground Floor

241

-

-

... More
First Floor

156.9

-

-

... More
Second Floor

166.31

-

-

... More
Third Floor

434.25

-

-

... More
Fourth Floor

331.37

-

-

... More
Waterproofing Treatment :- Liftpit :- Providing waterproofing for Liftpit :- Cleaning the inside surface & exposing the all construction joints (20 mm x 20 mm grooves) & honey combs, filling & sealing with Microcrete - 4 & cementitious pressure grouting of joints with expanding grout & polymer sika / perma Intreplast EP @ 0.5 kg + Sika Latex 0.5 kh/50 kg of cement. Providin & applying Sika Top seal 109 hi ( Two component Based acrylic polymer coating ) two coats followed by a protection plaster over a bond coat of sika Latex ( 1:4:6) & finish with net cement punning complete as per manufacture specification and direction of Engineer-In-Charge.

-

-

-

... More
Ground Floor

74.91

-

-

... More
G.R.C. JALI - Providing and fixing glass reinforced concrete (G.R.C) Screens in approved size, pattern, design, shadeand thickness of 50mm on frame and design element in 30mm thick have weight approximately between 3.5 - 4 kg per sq.ft .and color of M/S Unistone make or equivalent. The above weight and having at least 50% void space. The screens should be made from 53 grade white portlsnd cement manufactured by N.E.G JAPAN or equivalent, super plasticizers manufactured by BASF or equivalent, polymers manufactured by BASF or equivalent and U.V resistant synthetic inorganic pigments should be used for pigmentation manufactured by BAYFERROX (Germany) or equivalent. The matrial casting should take place in frp molds. The fixing of screens should be Dry fixing i.e. to be done with M.S Galvanized clamps, fixtures and fasteners of Hilti/fischer.

-

-

-

... More
Ground Floor

24.28

-

-

... More
First Floor

24.13

-

-

... More
Second Floor

26.54

-

-

... More
Third Floor

29.01

-

-

... More
Fourth Floor

29.07

-

-

... More
Structural Glazing. Providing and fixing of Fixed Glazing with part Top hung of approved make to be fabricated from roll formed sections made of pre-painted steel (base steel as per IS-513 of 0.6 mm thick “D” quality, galvanized as per IS-277 with zinc of 120Gm/Sq.mtr) with paint specification being with primer of 5-7 microns and finished paint with polyster paint (Black /Pearl white/ Chocolate Brown) of 12-16 microns alongwith the alkyd backer at the back of 5-7 microns and the sizes of outer frame being of 46x52 mm and with all vertical and horizontal mullions are of 46x70 mm and fixed beadings are of 18x25 mm. Top hung shutter should be of 46 x 46 mm. Accessories / gaskets are to be used as per the manufacturer’s supply and specification like handle being made of high grade aluminium powder coated and with nylon receiver and gasket will be made of EPDM. All corner brackets are to be made of CRCA with zinc phosphating.The mullion caps and louvered-clips should be of glass filled nylon. The sections are to be cut to length ,mitre joined with corner bracket and frames are fixed to the concrete/masonry walls by means of self expanding screws and glass to be used of 5mm reflective with all taxes complete.

-

-

-

... More
Ground Floor

239.04

-

-

... More
Supply and installation of Stainless steel ceilings are the safest when it comes to sanitizing and disinfecting. So easy to wash and wipe often and the results visible to all from housekeeping to auditors to patients and doctors alike. Well, Serge Astral SS does duty in this ICU. Clip-in tiles, Sj having 600x600x0.6mm having weight 2kg/m2, square edge, bulkheads made up of SS Material sheets installed in ceiling using Spring-T system. Spring-T system of 600x600mm module includes Skelet WA15W30, sectional thickness 0.4mm, with unequal flanges of 15/19mm, length 3000mm, fixed along the perimeter of walls with the help of nylon sleeves and suitable fasteners at 300mm centers. Then Hold-on ceiling clamp hung from the soffit at 600mm centers bothways with Hanger rod and soffit cleat. Strut Spring-T is then held in position by hold-on clamp @ every 600mm centers. Astral Plus Clip-in ceiling tiles 600x600x0.6mm are then clipped into Spring-T."Technical Parameters Fire (Class) - A. Acoustics - nil (For E300 Mounting). Thermal conductivity (W/mk)-na Climate (°C, RH) -50, 99. Light reflectance (%) -75 Green (VOC, RC %) - Low, 25, Finish-Matt HAS Anti Bacterial H+V+, including cost of all materials, all labour, sundries, T&P etc. complete in all respect as per direction of Engineer-in-Charge

-

-

-

... More
Ground Floor

337.37

-

-

... More
First Floor

385.99

-

-

... More
Second Floor

375.97

-

-

... More
Third Floor

338.12

-

-

... More
Fourth Floor

309.49

-

-

... More
GYP BOARD CEILLING :- Providing and fixing False ceiling as per Saint Gobain Specifications made of standard G.I. Sections and 12mm thick gyp board sheets inclusive of all hangers, edge members and other clips complete, with sheets fixed with proper Philip fastner by power drills and joints duly finished ensuring level in line, complete with putty, primer and painting of approved make and colour. Cost includes cutouts for electrical fittings, materials, labour, T&P etc complete as per direction of the Engineer-in-charge. (Basic Rate of Gypsum Board 12mm thk. Rs.303/ sheet).

-

-

-

... More
Ground Floor

337.37

-

-

... More
First Floor

385.99

-

-

... More
Second Floor

375.97

-

-

... More
Third Floor

338.12

-

-

... More
Fourth Floor

309.49

-

-

... More
Providing 2.5cm thick Grading Concrete over roof slab with cement concrete (1:2:2) using 6mm size black hard granite crusher broken chips and screened & washed sharp sand for mortar and finished smooth to the rough surface of slab including watering and curing with cost, conveyance, royalties of all materials with cost of all labour, labour cess and T&P required for the work etc. complete in all respect as directed by the Engineer in charge.

-

-

-

... More
Terrace Floor

862

-

-

... More
Waterproofing Treatment :- Terrcae Roof Top Surface. Providing test first to be done , application of nerolac perma guard 2k in 2coats over the roof slab & continue over the parapet wall reinforced covering with 1:4 cm admixed with nerolac perma plast-o-proof STD @ 100gm per 50kg cement over the joint to terrace to parapet over bond coat perma latex SBR (1:4:6) followed by a the protection screed (1:1.5:3) in panel of size 2mtrx2mtr to drain the water towards the rain water pipe & finally filled the grooves 8mm x10mm with nerolac perma polyseal (poly sulphide sealant ) complete as per manufacture specification & direction of engineer incharge

-

-

-

... More
Terrace Floor

862

-

-

... More
EXPANSION JOINT TREATMENT:- Supplying and Installing of Expoband one Flexible Polyolefin (FPO) membrane system which is designed to be bonded over expansion and movement joints up to 150mm in structures to prevent the passage of water having Elongation at break: 400%, Tensile Strength: 12.5N/mm2 (DIN EN 12311-2 Method B), Water vapour permeability: 2.7g/Sqm/day (DIN EN 1931-Method B). It is bonded in position using two-part epoxy adhesive, Nitobond PC40 as per manufacturer direction after proper fixing of the necessary backup materials as specified and directed by the Engineer In-charge. The item rate shall be including of all kinds of labour, tools & tackle, machineries, lead & lift, mathadi charges, curing, wastages, consumable, cleaning, shifting of debris outside the site premises, surface preparation etc. complete as per design, drawing & instructions of EIC

-

-

-

... More
Ground Floor

65.57

-

-

... More
E.I. WORK Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/ Norpack/ Anchor/ Kinjal 6A modular type (anti bactorial & flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) (anti bactorial & flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.

-

-

-

... More
GROUP-A

153

-

-

... More
GROUP-B

300

-

-

... More
GROUP-C

400

-

-

... More
Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( (anti bactorial & flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.

190

-

-

... More
Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( (anti bactorial & flame retradant type)) with suitable size modular box & cover(anti bactorial & falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.

25

-

-

... More
Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)((anti bactorial & flame retradant type)) with suitable size modular box & cover(anti bactorial & flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.

60

-

-

... More
Supplying,fixing of 1x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+1 no 6A switch & socket(modular type) ( (anti bactorial & flame retradant type) with suitable size modular box & metallic cover plate (both side)(anti bactorial & falme retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN)/Panasonic (vision) (For equipement power)(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.

20

-

-

... More
Supplying,fixing of 3x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+3 nos 6A switch & socket(modular type) ( (anti bactorial & flame retradant type) with suitable size modular box & metallic cover plate (both side)(anti bactorial & falme retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. Make-Schneider (Zencelo)/ legrand( ( Myrius-NEXT GEN)) /Panasonic (vision) (For equipement power). (Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.

20

-

-

... More
Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/RR KABLE in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ Norpack/ Anchor/ Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5)

750

-

-

... More
Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ Norpack/ Anchor/ Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5)

2000

-

-

... More
Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ Norpack/ Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5)

1200

-

-

... More
Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ Norpack/ Anchor/ Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit .(LFDB TO LBDB/UBDB) (2X6+1X2.5)

750

-

-

... More
Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ Norpack/ Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit.(LFDB TO LBDB/Medical equipement) (4X6+2X4)

250

-

-

... More
Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ Norpack/ Anchor/ Kinjal as required as per direction of Engg.-in-Charge. 4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit .(LFDB TO FLOOR PANEL TO TPN BDB power) (4X10+2X6)

250

-

-

... More
Supplying and fixing 32 amps, 240 volts, SPN, industrial type socket outlet, with 2 pole and earth metal enclosed plug top along with 32 amps. C-series, SP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet, and complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge.. . Make-Legrand/Schneider/Siemens ISI marked as approved,All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.(for equipement only & split AC at required area)

30

-

-

... More
Supplying and installation of 25A AC starter Modular type, Schneider/Siemens/Legrand coil voltage-230 Volt A.C. on mod Box of suitable size including modular coveras required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.

30

-

-

... More
Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover.Make-Schneider (Zencelo)/ legrand( ( Myrius-NEXT GEN)) /Panasonic (vision)as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.

20

-

-

... More
S/F of Bakelite angle holder/batten holder (make-Anchor/Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.

30

-

-

... More
Sub-Head II (Light fitting Fixture & Fan)

-

-

-

... More
Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years.

33

-

-

... More
Supplying, installation, of exhaust fan of heavy duty 380 mm sweep 1400 rpm with louvers(Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection .as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years.

10

-

-

... More
Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.. .(With fan Regulator)

180

-

-

... More
Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years

70

-

-

... More
Supplying and fixing of Energy efficient Recess /Surface mounted square/round shaped LED luminaire made up of CRCA powder coated sheet steel of 25W (595mm x 595 mm x70mm) and system lumens output not less than 3250 lumens (130 lm/ wt) with diffusers for better light transmission and pure effect with High luminous flux LEDs for better light output, CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (5 years warranty)supply .as required as per direction of Engg.-in-Charge (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) . The luminaire must be Replacement Warranty will be 5 years.

170

-

-

... More
SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years .

140

-

-

... More
SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years

40

-

-

... More
Supplying and fixing of Energy efficient recessed mounted LED luminaire made up of CRCA powder coated housing, Top opening clean room LED luminaire of 595mm x 595 mm x70mm size with of 45 W and system lumens output not less than 4500 lumens , IP65 ,dust free & zero maintenance , anti glare high transmittance PMMA diffuser , operating volatge range 150-265 V, high performance potentiometric electronic driver for zero maintenance , 2.5 KV internal urge protection, L70 B 50: 50,000 hrs., CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,,IP 65 protection complete with all other accessories suitable for operation on 230 V, 50 Hz supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2years. .CLEAN ROOM FITTING for OT.

12

-

-

... More
Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge . (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved.

180

-

-

... More
BDBS,DB,AC DB,FLOOR PANELS,MCBS

-

-

-

... More
Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9 as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years.

-

-

-

... More
4 Way(8+4+12+12) Way TPN MCB DD 7 Segment DB Horizontal Type as per IEC 61439-3 with configuration of incomming I-8 modules,incomming II-4 modules,sub incommer-12 module & out going-12 modules,suitable for Flush mounting and Surface mounting with Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years

20

-

-

... More
Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years

12

-

-

... More
Supplying and fixing 6-32 Amps rating, C series,10KA breaking capacity,SP, 230 volts, MCB . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 3 years..

336

-

-

... More
Supplying and fixing 40 amps rating, 415 volts, C series,10KA breaking capacity, FOUR poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 3 years.

10

-

-

... More
Supplying and fixing 40 Amps rating,C series,10KA breaking capacity, 4P, 415 volts, RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 3 years.

10

-

-

... More
Supplying and fixing 40 Amps rating,C series,10KA breaking capacity, 2P, 240 volts, RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 3 years.

12

-

-

... More
Supplying and fixing 63Amps 4P 415 volts MCB Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB with connections as per direction of Engg.-in-Charge..Warranty on MCB is 3 years.

10

-

-

... More
Supplying and fixing 63Amps 4P 415 volts RCCB 30 mA Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..The RCCB should be Replacement Warranty will be 3 years.

10

-

-

... More
Supplying and fixing 40 amps rating, 240 volts, C series,10KA breaking capacity, Double poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 3 years.

12

-

-

... More
Supplying and fixing of Type (I +II) 3P+N SPD with Lightening impulse discharge current I imp(10/350) µs 7kA/POLE and 25kA total and maximum discharge current Imax(8/20) msec-50kA,with response time25 nanosec in the incommer of Distribution board, Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB with connections as per direction of Engg.-in-Charge.The SPD should have Replacement Warranty will be 3 years.

20

-

-

... More
(Earthing) INSTALLATION

-

-

-

... More
Supplying,installation,testing & commissioning Of Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (WITH charcoal and salt) as required as per direction of Engg.-in-Charge.

6

-

-

... More
Supplying,installation,testing & commissioning of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.The entire earthing system should be Replacement Warranty will be 2 years

4

-

-

... More
Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. Tapping from 50mm x 6 mm bus bar to all sub panel

200

-

-

... More
Providing and fixing 25mm x 5 mm copper strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. Main LT ROOM dg panel earthing.

150

-

-

... More
Providing and fixing 50mm x 5 mm copper strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. MainLT ROOM dg panel earthing.

50

-

-

... More
Providing and fixing 50mm x 6 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. 2 runs from main LT room to electrical shaft upto 5th floor.

50

-

-

... More
CABLING AND END TERMINATION MAIN AREA

-

-

-

... More
Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/ Polycab/ HAVELLS/ RR KABLE/ Gloster of following size cables as per direction of Engg.-in-Charge.

-

-

-

... More
3.5core x 240 sq mm

200

-

-

... More
3.5core x 150 sq mm

100

-

-

... More
3.5core x 95 sq mm

100

-

-

... More
3.5core x 70 sq mm

75

-

-

... More
4core x 16 sq mm

200

-

-

... More
4 core x 6 sq mm

100

-

-

... More
3.5core x 35 sq mm

200

-

-

... More
LAYING OF CABLE

-

-

-

... More
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.

200

-

-

... More
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.

270

-

-

... More
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 120 SQ. MM but not exceeding 400 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.

210

-

-

... More
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge.

30

-

-

... More
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge.

55

-

-

... More
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in open duct etc as required as per direction of Engg.-in -charge.

40

-

-

... More
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM in open duct 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge.

90

-

-

... More
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge.

25

-

-

... More
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 120 SQ. MM From 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge.

30

-

-

... More
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 400 SQ. MM From 120 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge.

20

-

-

... More
Supplying and making end termination with brass double compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge.

-

-

-

... More
3.5 core x240 sq mm

6

-

-

... More
4 core x16sq mm

25

-

-

... More
3.5 core x35 sq mm

20

-

-

... More
3.5 core x95 sq mm

8

-

-

... More
3.5 core x150 sq mm

8

-

-

... More
3.5 core x70 sq mm

10

-

-

... More
Providing,fixing and laying of following dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge.

-

-

-

... More
50 mm dia

40

-

-

... More
Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge.

-

-

-

... More
200 mm dia

200

-

-

... More
PANELS

-

-

-

... More
MAIN CONTROL PANEL AT GF

-

-

-

... More
S/I/T&Commissioning of CPRI Tested LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by siemens gray powder cote paint fallowed by 9 tank acid treatment is designed as G.A drawing as per direction of Engg.-in-Charge.Warrentee period of replacement of panel & accessories must be 3 years & compelete test certificate must be submitted along with panel board including component list.60x10mm seperate Aluminium Earth busbar should be installed. In commer-1-01 number of 400A 4P Icu=100%Ics,36Ka LSIG MCCB with micro processor based release Electrical locking for normal & DG ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS(FROM 250 KVA TRANSFORMER). Busbar-1&2 04 numbers of 400Amps Cupper busbar with duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing). Sub In commer-01 number of 250A 4P Change over Switch. Out going- 07 numbers of 125A 4P MCCB,,25Ka MCCB withTMR based release with adjustable overload ,Icu=100%Ics( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS). Out going- 3 numbers of 250A 4P Icu=100%Ics,,36Ka MCCB withTMR based release with adjustable overload ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS). Out going- 7 numbers of 100/63A 25ka 4P Icu=100%Ics MCCB ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS). Out going- 7 numbers of 63A 4P MCB (make- Legrand-DX3/Schneider-Acti 9/Siemens-Betaguard). Instrument- (i) 06 numbers phase indicating lamp with toggle switch & HRC fuse. (ii) 02 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication with RS 485 COMPACTIVITY FOR bms data. 1 no. 3P+N 12.5kA/POLE SPDwith 63A 4P MCB,10Ka(TYPE-I+II)(make- Legrand/Schneider/Siemens)

1

-

-

... More
FLOOR POWER PANEL

-

-

-

... More
S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 3 years & compelete test certificate must be submitted along with panel board including component list.Type 2 SPD,40kA shall be installed in the incomer. 20X10mm Separate Aluminium Earth bus bar should be installed. In commer- 01 no 125A 4P MCCB 16kA,C series with on/off trip indication Light load for each floor. ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS). Busbar- 04 numbers of 150Amps 25*5mm copper bus bar Electrolytic copper busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator. Out going- 06 nos 63A 4P MCB 10kA,C series Light load to LDBs . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9. Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse. (ii)multifuction meter (A,f,V,Kwh,kvarh,pf) with suitable rating of CT accuracy class 1 as per incomer rating.

5

-

-

... More
FLOOR LIGHTPANEL

-

-

-

... More
S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. )as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 3 years & compelete test certificate must be submitted along with panel board including component list. Type 2 SPD,40kA shall be installed in the incomer. 20X10mm separate Aluminium Earth bus bar should be installed. In commer- 01 no 100A 4P MCCB 16kA, with ROM & S. Link. ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS) (Icu=100%Ics)with shunt trip. Busbar- 04 numbers of 100Amps, Electrolytic copper busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator. Out going- 06 nos 63A 4P MCB 10kA,C series for Light BDB. Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9. Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse. (ii) multifuction meter (A,f,V,Kwh,kvarh,pf) with suitable rating of CT accuracy class 1 as per incomer rating.

5

-

-

... More
AC O/D PANEL

-

-

-

... More
S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing.as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 3 years & compelete test certificate must be submitted along with panel board including component list. 40x10mm Separate Aluminium Earth bus bar should be installed. In commer- 01 no 250A 4P MCCB 25kA,C series with on/off trip indication Light load for each floor. ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS). Busbar- 04 numbers of 250Amps 25*10mm copper bus bar Electrolytic copper busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator. Out going- 05 nos 63A 4P RCBO 300MA,C series . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9. Out going- 04 nos 32A 4P RCBO 300MA,C series . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9. Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse. (iii) multifuction meter (A,f,V,Kwh,kvarh,pf) with suitable rating of CT accuracy class 1 as per incomer rating. 1 no. 3P+N 12.5kA/POLE SPDwith 63A 4P MCB,10kA(TYPE-I)(make- Legrand/Schneider/Siemens).

1

-

-

... More
UPS PANEL

-

-

-

... More
S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. (FOR ALL MAIN CONNECTED LOAD) BUILDING EMERGENCY LIGHT)as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 3 years & compelete test certificate must be submitted along with panel board including component list. Type 2 SPD,40kA shall be installed in the incomer. Separate Aluminium Earth bus bar should be installed. In commer- 02 numbers of 63 Amps 4P MCCB 25KA. Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 (Icu=100% Isc) with shunt trip & axulary for BMS & mechnical inter locking for one incommer source to other. Busbar- 04 numbers of 100Amps Electrolytic copper busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator. Out going- 15 nos 32A 2P MCB UPS Light load for each floor. Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse. (ii) multifuction meter (A,f,V,Kwh,kvarh,pf) with suitable rating of CT accuracy class 1 as per incomer rating. NB- This panel should have proper earth by suitable rated copper flat.

1

-

-

... More
CABLE TRAY /RACE WAY FOR DISTRIBUTION OF POWER

-

-

-

... More
Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge.

40

-

-

... More
Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 300mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge.

20

-

-

... More
Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 400mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge.

10

-

-

... More
Supplying,fixing of FLOOR RACE WAY WITH JUNCTION box GALVANIZED(GC) type AS PER EN-ISO-1461 , with internal dimensions of size 38mm(H) x 225mm(W), of MAKE- Profab/OBO/Neidax .(With all accessories,bend,cover,supporter)WITH REQUIRED SIZED JUNCTION BOX ,COVER CONNECTOR as required as per direction of Engg.-in-Charge.(3 COMPARTMENT TOTAL 54 MM HEIGHT.

50

-

-

... More
20 PASSENGER BED CUM HOSPITAL LIFT WITH WIRRING(1.1)

-

-

-

... More
Supply,Installation, Testing & Commissioning of of 20 Passenger-cum-bed lift gearless with Machine room Capacity(1360 Kg), with minimum shaft size of 2100mm(Left to right)x2900mm(Front to back) Elevator G+4 Floors with ACVVVF drive/Control with ARD =1.00 MPS, SS honeycomb interior ,2hr fire rated door with simplex operation without attendant car position indicators,battery operated alarm bell & emegency light,SS honeycomb finish door finished car interior, recess Granite flooring ,power operated centre opening automatic sliding SS honeycomb finish doors for car entrance & hoist way entrance etc .All SS material shall be of grade SS-304 and minimum thickness of 1.6mm. Machine beams,buffer support channels,facia plate including sills pit ladder metal screen in Elevator pit etc.as per specifiaction including cost of (i)Overload detection,(ii)Voice announcement,(iii) Intercom,(iv)Braille Buttons with all Civil & Electrical works required for installation of Elevator in the existing lift well and machine room,scaffolding ,floor cutting including Fireman's switch complete in all respec as per the instruction of Engg. in charge.The Elevator should be suitable for physically handicapped person. make:OTIS/Mitsubishi/Schindler/Johnson

3

-

-

... More
Lightning Protection :- Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/Equivalent

300

-

-

... More
Supply of Roof conductor holder for parapet- Polyamide Conductor holder:With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/Equivalent

150

-

-

... More
Supply of Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance. Tested as per IEC 62561. Make-OBO/Dehn/Equivalent

20

-

-

... More
Supply of Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Tested as per IEC 62561.(2nos/expansion piece ).Make-OBO/Dehn/Equivalent

12

-

-

... More
Supply of 1 mtr vertical air terminal with mounting accessories on the flat surface to meet the requirements of IS/IEC 62305. Tested for Electrical , mechanical and chemical as per IEC 62561. Tested for 100kA lightning current. Make-OBO/Dehn/Equivalent

12

-

-

... More
Supply of Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3 Nominal size Ø10/16 mm aluminium rod: 2 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. Tested as per IEC 62561. Make-OBO/Dehn/Equivalent

4

-

-

... More
Supply for Providing of Stand for Fang Fix system 16 kg with base and clamp ,made up of frost resistant concrete and clamp tested upto 100KA lightning current . Make-OBO/Dehn/Equivalent

8

-

-

... More
Supply for Providing of Stand for Fang Fix system 16 kg made up of frost resistant concrete. Make-OBO/Dehn/Equivalent

8

-

-

... More
Supply of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Engineer. Tested for 100kA lightning current. Make-OBO/Dehn/Equivalent

8

-

-

... More
Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr Height for Test Joint .Internal dimensions: 100x100x48 mm Make-OBO/Dehn/Equivalent

8

-

-

... More
Supply of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized. Tested as per IEC 62561. Make-OBO/Dehn/Equivalent

100

-

-

... More
Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. Make-OBO/Dehn/Equivalent

15

-

-

... More
Supply of flat conductor holder- Fit: FL 30, With mounting hole 6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from hot-dip galvanised steel, Bottom section from polyamide, black. Tested as per IEC 62561. Make-OBO/Dehn/Equivalent

20

-

-

... More
Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. Make-OBO/Dehn/Equivalent

3

-

-

... More
Supply of UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 17.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2 Make-OBO/Dehn/Equivalent

8

-

-

... More
Supply of universal clamp made of SS to connect rod with flat conductor Make-OBO/Dehn/Equivalent

8

-

-

... More
Supply of Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested Make-OBO/Dehn/Equivalent

8

-

-

... More
Supply of The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system. Make-OBO/Dehn/Equivalent

8

-

-

... More
Installation of The above arrangements including all accessories as per Direction of Engg. In charge.

1

-

-

... More
Supply ,installation ,testing & commissioning of 20KVA Parallel UPS SYSTEM WITH IGBT based inverter system, true online double conversion system, inbuilt isolation transformer & automatic phase sequence corrector of 3ph in put to 3 ph output,415V, with built in BMS with battery back up up to 30 minutes with MS Rack for battery Housing, DC cable 7 Mtr with SFU and links for installation (Battery required: 12V, 65AH, 32 No.s) protection for fault by OL,UV,EF,GF,OC,Ph. (Make:Numeric /APC/ Vertiv) LOAD OF OT,ICU) as per direction of Engg.-in-Charge. Warrentee period of all accessories & component & system must be 2 years & compelete test certificate must be submitted along with ups including component list & SLD.

2

-

-

... More
Supply & Laying of Cat6 23Awg UTP Cable, through existing conduit, Make: Legrand/Systimax/Panduit

100

-

-

... More
Supply & fixing of RJ-45Jack of Category 6 with Dual-port British-style Face plate 86x86 mm with Curveture and wall mount box Make: Legrand/Systimax/Panduit

34

-

-

... More
Supply & fixing of Cat6 24 Port Jack Panel loaded with individual keystone:Make: Legrand/Systimax/Panduit

7

-

-

... More
Supply & Installation of Cat6 Factory crimpped moulded patch cord,1mtr, Make: Legrand/Systimax/Panduit

50

-

-

... More
Supply & Installation of Cat6 Factory crimpped moulded patch cord, 2mtr. Make: Legrand/Systimax/Panduit

10

-

-

... More
Supply & Installation of 6F Single Mode Armoured FO Cable through existing conduit. Make: Legrand/Systimax/Panduit

100

-

-

... More
Supply, Installation,Testing & Commisioning of 6Port Rack Mount Loaded LIU including SM SC Adaptor and Pigtail. Make: Legrand/Systimax/Panduit

7

-

-

... More
Supply, Installation,Testing & Commisioning of Single Mode SC-LC Type OFC Patch Cord, 2mtr length.Make: Legrand/Systimax/Panduit

7

-

-

... More
Supply & Installation of 1000Base LX Fiber Transceiver. Make: Cisco/Digisol/HP

7

-

-

... More
Supply and installation of 24 Port Layer2 Giga (10/100/1000BaseT) PoE Switch with 4 x 1Gig SFP Port , Switching Capacity 56 Gbps, Throughput 41.7 Mpps ,Management Port 1 x RJ 45 Console port ,PoE power budget 270 Watt, Switch should support IEEE 802.3af & IEEE 802.3at standard ,MAC Address 16K , Jumbo Frame 12K ,Temperature Working 0°C~50°C, storage -40°C~70°C, Power Supply AC: 100~240VAC.Digisol Model No. DG-GS1528HPE-P/Cisco/HP

7

-

-

... More
Supply & Installation of 9U/500Wall Mount Rack with FAN, PDU, Cable manager and H/W Pkt. Make : Valrack/Rittal/APW

6

-

-

... More
Supply & fixing of 24U 600/650D UL Listed Floor mount Rack loaded with one no 10Skt 5/15A power distribution unit, 4nos cable manager, Four nos 90CFM FANs, 1no HD Self and one pkt H/W screw. Make : Valrack/Rittal/APW

1

-

-

... More
Supplying and fixing of Hybrid EPABX system equipped with 128 Analog extensions and 6 Analog Trunk, including required hardware and software etc as reqd. Make-Matrix/Siemens/Coral

1

-

-

... More
Supplying desktop telephone sets with colour ID as reqd Make-Panasonic/Beetel

22

-

-

... More
S/f of 50 pair MDF box with 3 nos. krone module.

2

-

-

... More
S/f of 5O pair krone box with k2 no. krone module

2

-

-

... More
Supplying and drawing following pair 0.5 sq mm FR PVC insulated annealed copper conductor, unarmored telephone cable in the surface/ recessed steel/ PVC conduit as required.

-

-

-

... More
2 Pair

1000

-

-

... More
20 Pair

200

-

-

... More
Supplying and fixing of following sizes of medium class PVC FRLS conduit ISI marked along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per direction of Engg.-in-Charge .Make-AKG/ Norpak

-

-

-

700

-

-

700

-

-

... More
A.FIRE PROTECTION WORK (A-1) FIRE EXTINGUISHERS Providing & Fixing of fire extinguishers with necessary accessories, stand, trolley, etc. 6 Kg ABC (Powder Type) Fire Extinguisher. In HP Mild Steel Cylinders ISI marked fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged with ABC powder (Mono Ammonium Phosphate) pressured by Nitrogen complete in all respects including wall suspension bracket and conforming to IS:15683safex/minimax/safeguard/Ceasefire

28

-

-

... More
ISI marked (IS:15683) portable AFFF Mechanical foamfire extinguisher, Foam type capacity 9 liters with gun metal cap and nozzle and complete in all respects including initial fill and wall suspension bracketssafex/minimax/safeguard/Ceasefire

3

-

-

... More
ISI Marked portable fire extinguisher, 4.5 kg CO2 type fire extinguishers complete in all respect including initial fill and wall suspension brackets & shall conform to latest IS 15683safex/minimax/safeguard/Ceasefire

13

-

-

... More
Supplying and installing at approved location approved make fire buckets (3 nos./set) of 24 gauge galvanized steel sheet, standard 9 litre capacity and of round bottom shape, painted white inside and black on the bottom, inscribed with letters '' FIRE'' in black and gold with dry clean fire sand. The scope shall also include the stand for mounting the sand bucket.

1

-

-

... More
Supplying, installation, testing and commissioning of 2kg Eco friendly stored pressure type filled with HFC 236 (Clean agent fire extinguisher having zero Ozone depletion potential ) Clean agen fire extiguisher with safety seal, pressure guage, controlable discharge mechanism, helium leak detection, tested and confirming to IS:15683 complete with initial chage as required. Make-Safex/Fireshield/Ceasefire

4

-

-

... More
(A-2) FIRE RISER: Supplying, installation testing and commissioning of the following.‘C' class MS pipe as per IS1239 with welded / flanged / screwed joints and with heavy clamps, hangers, brackets or pipe supports (all with screwed/welded joints) as required including MS pipe of shorter lengths, tapering connecting pieces, short or long bends, forged specials like sockets, union nuts, elbows, reducers, plugs, Tees etc. Complete to make the system operative as required by LFA / TAC authorities. The pipes will have to be laid and fixed on walls, ceilings, into brick walls or RCC with lead anchor fasteners. The work includes making holes in brick or RCC walls, slabs/ roofs and making good the damages by bringing to the original condition to the satisfaction of the Consultant/Client and painting two coats of approved shade(Post office red)of enamel paint over a coat of approved primer for over ground / overheads pipes. Make- TATA/Jindal/Sail

-

-

-

... More
100 mm

60

-

-

... More
80 mm

12

-

-

... More
Supply, installation, testing and commissioning of ci Butterfly valve of PN 1.6 rating with metal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required: 100 mm. Kartar/H-sarker/zoloto/Kirloskar

2

-

-

... More
Providing and fixing Single headed hydrant having outlet of 63 mm dia (2.1/2”) N.B. hydrant (IS:5290) landing valve in Stainless Steel Morris Pattern instanteous coupling type TAC / LFA approved & ISI certified heavy type hydraulically tested to 1.5 times working pressure with necessary nuts, bolts etc. Make-Kartar/Newage/Fireshield/Minimax

10

-

-

... More
Providing & fixing 63mm dia RRL hose pipe as per IS 636 TYPE A TAC/ LFA approved of 15 mtr length of approved pattern and size including SS male and female Coupling duly bound with copper wire etc. complete. Make-Kartar/Newage/Fireshield/Minimax

20

-

-

... More
Providing and fixing fire hose cabinet to house fire hydrant & hose, including all other related accerrories fabricated from M.S. sheet (2mm thick) of fully welded construction having front door with locking arrangement, partially glazed with 4 mm thick glass. Cabinet shall be powder coated & painted with post office red colour of size as approved by the engineer-in-charge to house 15 mtr.x2 nos. hoses. The hose box size is 750 mm x 600 mm x 300 mm. Make-Kartar/Newage/Fireshield/Minimax

10

-

-

... More
Supplying & fixing first aid fire hose reel of thermoplast braided suitably reinforced 20 mm size & 30 m standard length with 5 mm tapering branch nozzle, 25mm dia. Pipe to connect to riser. Hose to be swinging type wall mounted drum & recessing into hose cabinet to suit location including fixing with lead anchor fasteners & bolts (Including drum and swivel arrangement) etc complete. (IS 884).Make-Kartar/Newage/Fireshield/Minimax

10

-

-

... More
Supplying and fixing specially designed orifice plates (minimum 6 mm plate thickness) on hydrant outlets of landing valves including distant pieces of suitable size for reducing delivery pressure to 3.5 kg/ sq.cm at hydrant valve , as required by LFA complete with necessary accessories, etc. complete.

10

-

-

... More
Providing and fixing Stainless Steel standard branch pipe dia 63 mm inlet with nozzle 20 mm dia outlet conforming to IS : 903, suitable for instantaneous connections to hose coupling etc. as required: Make-Kartar/Newage/Fireshield/Minimax

10

-

-

... More
Providing, fixing and testing forged brass 25 mm dia screwed inlet single acting air release valve with asll accessories. Kartar/newage/equivalent

3

-

-

... More
Providing, fixing and testing forged 25 mm dia screwed ball valve with accessories.Kartar/Zoloto/Eq.

11

-

-

... More
(A-3)EXTERNAL HYDRANT SYSTEM Supplying, installation testing and commissioning of the following ‘C’ class MS Pipe IS 1239 above 150 nb IS 3589 over ground pipes and road crossing under ground with welded / flanged connection with saddles, supports (all with screwed/welded joints) as required including pipe of shorter lengths, tapering connecting pieces, short or long bends, elbows, reducers etc. Complete to make the system operative as required by LFA / TAC authorities.The above ground pipes will laid on concrete pedestal with structural steel or Steel bracket & painting two coats of approved shade(Post office red)of enamel paint over a coat of approved primer for overheads pipes and road crossing pipes will laid through humepipe with wrapping coating. Make- Jindal/TATA /Sail

-

-

-

... More
150 mm

278

-

-

... More
80 mm

5

-

-

... More
Providing and fixing hydrant valve . With flanges and accessories and supply, fixing 63 mm dia SS Single headed Hydrant Valve in the courtyard IS:5290 Including 2 coats of approved enamel paint (red) over a coat of primer, complete with 2.1/2” ‘Morris’ pattern instaneous couplings, etc. complete. Make-Kartar/Newage/Fireshield/Minimax

5

-

-

... More
Providing & fixing approved 63mm dia RRL hose pipe as per IS 636 TYPE A TAC/ LFA of 15 mtr. standard length of approved pattern and size including SS male and female Coupling duly bound with copper wire etc. complete. Make-Kartar/Newage/Fireshield/Minimax

10

-

-

... More
Providing and fixing Stainless Steel standard branch pipe dia 63 mm inlet with nozzle 20 mm dia outlet conforming to IS : 903, suitable for instantaneous connections to hose coupling etc. as required: Make-Kartar/Newage/Fireshield/Minimax

5

-

-

... More
Providing and fixing TAC approved fire hose cabinet to house fire hydrant & hose, including all other related accerrories fabricated from M.S. sheet (2mm thick) of fully welded construction having front door with locking arrangement, partially glazed with 4 mm thick glass. Cabinet shall be powder coated & painted with post office red colour of size as approved by the engineer-in-Charge to house 15 mtr.x2 nos. hoses. The hose box size is 750 mm x 600 mm x 300 mm . Make-Kartar/Newage/Fireshield/Minimax

5

-

-

... More
Supplying and fixing 4 way Fire Brigade service inlet of size 150 mm dia. with 4 No. 63mm (2.1/2") size Stainless Steel male outlets ( Stainless Steel male coupling) including metallic cover of mild steel and glass front, indicator plates complete. as required by LFA/TAC/engineer in charge kartar/zoloto/Kirloskar

1

-

-

... More
Supplying and fixing Fire Brigade draw out connection of size 100 mm dia. SS male outlets ( Stainless steel male coupling) including 100 mm dia foot valve etc. complete to be connected with fire water tank. as required by LFA/TAC/engineer in charge kartar/zoloto/Kirloskar

1

-

-

... More
Supply and installation, testing and commissioning of Isolation Sluice valves tested to ISI marked ,PN 1.6 with CI body, bonnet & brass trim parts, & having necessary companion flanges, bolts, nuts, gasket packing and any other spares, including indicator for open and shut position to be installed as per fire practice etc complete. 150 mm dia. Kartar/H-sarker/zoloto/Kirloskar

1

-

-

... More
Supply,Installation,Testing & Commissioning of Air vessel made of 250mm dia, 8mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia Gun metal wheel valve, with required accessories, pressure gauge and painting with synthetic enamel paint as required.

1

-

-

... More
(A-4)FIRE PUMPS & RELATED ACCESSORIES Supplying & installing completely testing & commissioning of End Suction Back Pull Out pump set having pump speed of 2900 rpm, Pump Efficiency not less than 65%, with CI Casing, Bronze Impeller, SS 410 Shaft & Shaft Sleeve Connected through Flexible Coupling with a TEFC Sq. Cage Induction Motor mounted on a common base frame fabricated in MS Channel. Packing has to be of Mechanical seal. It has to be inclussive of all the pump accessories. The pump shall be capable of giving not less than 150% discharge at a head not less than 65% of the rated head. Motor to be of continuous rating Motor to be suitable for 415V, 50Hz, AC supply of 35 KW rating for the above pumps. Motor shall accept +/- 10% variation in voltage and +/- 3% variation in frequency. It has to be of IE2 efficiency class. etc. complete. Pump - Motor : Discharge : 2280 LPM, Head-70 mtr.kirloskar/Wilo/KSB

1

-

-

... More
Supplying, installing, testing and commissioning of End Suction Back Pull Out pump set having pump speed of 2900 rpm, Pump Efficiency not less than 25%, with CI Casing, Bronze Impeller, SS 410 Shaft & Shaft Sleeve Connected through Flexible Coupling with a TEFC Sq. Cage Induction Motor mounted on a common base frame fabricated in MS Channel.Motor to be suitable for 415V, 50Hz, AC supply of 5 to 11 KW rating for the above pumps. Motor shall accept +/- 10% variation in voltage and +/- 3% variation in frequency. It has to be of IE2 efficiency class. Packing has to be of Mechanical seal. It has tio be inclusive of all the pump accessories complete . The scope shall also include necessary coupling, coupling guard, base frame, foundation bolts etc. complete Pump - Motor: Discharge: 180 LPM, Head: 70 mtr. kirloskar/Wilo/KSB

1

-

-

... More
Supply, installation, testing & commissioning of diesel Engine driven common stand by pump, horizontal centrifugal end suction type with mechanical seal and capable to deliver 2280 LPM , to ensure a minimum pressure of 3.5 Kg/Sqcm at the farthest or topmost hydrant / sprinkler. Fire pump shall have C.I. casing, CS diffusers, bronze impeller (hard finished and dynamically balanced) and S.S. (304) Shaft with mechanical seal. The installation shall be complete with necessary pressure gauge with gun metal shut off cock on suction & delivery side. The pump shall coupled to not less than 35 kw of Diesel engine radiator water cooled type with speed not more than 1800 RPM and complete set shall be mounted on common base frame. Batteries & battery leads with stand, Fuel tank ( for 6 Hrs. operation ) with stand & gauge glass, Fuel piping with valves. The quoted rate shall includes radiator water cooling piping(if required) coupling guard and other standard accessories (as recommended by manufacturer) and foundation bolts, etc. complete. Pump shall be capable of furnishing Not less than 150% of rated capacity at a head of Not less than 65% of the rated head. The shut off head shall Not exceed 120% of rated head. flexible coupling, coupling guard,anti vibration pad & exhaust pipe connection complete as required. Pump - diesel engine: Discharge:2280 LPM, Head: 70 mtr. kirloskar/Wilo/KSB

1

-

-

... More
MCC for Fire Pumps : Design, manufacture, supply ,installation, testing and commissioning of following Automated Fire panel suitable for 415V, 3 phase, 4 wire, 50 hz power distribution system. The panel should be indoor, free standing, floor mounting, sheet metal clad, Cubicle, dead front, dust and vermin proof, compartmentalized design fabricated out of 2mm CRCA sheet complete with Cu busbars, a separate earth bus bar to be provided through out the length of the panel. The incoming and outgoing feeders shall be accommodated in a modular multitier arrangement, adequate size cable alley, painting, earthing numbering, damper plate etc. as required as per direction of engineer-in-charge and as per local Fire Authority requirement.The panel shall be fabricated by only CPRI approved manufacturer As per the details below INCOMING 1 No 200A 25kA TP with solid neutral SDFU 1 Set of 400 Amps. TPN Cu. Bus bars with color coded heat shrinkable PVC sleeves. Indicator R,Y,B,ON,OFF,TRIP. Ammeter LCD type display+3 CTs,Voltmeter LCD type display OUTGOING FEEDER FOR Electri PUMPS - 01 No : 01 No 160 A TP MCCB, with star delta Starter contactor and OLR ratings as per type 2 co-ordination,with digital ammeter, voltmeter, ON,OFF push button, local remote switch,auto manual seclector switch etc. FEEDER FOR JOCKEY PUMP - 01 No: 01 No 32 A TP MCCB, with star delta Starter contactor and OLR ratings as per type 2 co-ordination, with Digital Ammeter,voltmeter, ON,OFF push button, local remote switch, auto manual selector switch etc. DIESEL ENGINE PUMP - 01 No a) 25Amps DPMCB - 01 No( b) Battery charger with transformer with rectifier resistance DC ammeter, DC voltmeter, Trickle / booster / off selector switch - 1 No (c) 1 set of indicating lamps for the following : 1. Phase indication 2. Battery charger on 3.Over load relay 4. DC supply on 5.Control switch on 6. Engine fails to start 7. Pump on 8. Low oil pressure 9. High water temperature10. Auto manual selector switch (d) 1 sets of push button stations for the following : 1. Engine Start 2. Engine Stop 3. Engine - hooter ACK 4. Engine - fault reset (e) Selector switches (Engine control, mode selector)-1 No ( f) Auxiliary relays / contactors / timer for sequence operating for starting and stopping of the engine - 1 set (g) Hooter for audio alarm (Industrial type) - 1 No. (h)Automatic source transfer Relay with 3 attempt starting,High Low Lube pressure, timers and relays as required and suitable contactor. All the components shall be housed in a common cubical made of 2mm CRCA sheet with required stiffeners ( if required). The panel shall be powder coated of approved color both inside & out side. The panel shall have both bottom & top cable entry provisions and panel shall be mounted on Pedestal of 300 mm height. Also panel shall have sufficient (min. 10 Nos) NO/NC contacts for extending the status( annunciation) of fire pumps to the Fire alarm panel. CPRI Approved Make of switchgear-Legrand/Schneider/Siemens

1

-

-

... More
Earthing with G.l. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry 'enclosure with cover plate having locking arrangement and watering pipe of 1.5 meter long etc. with charcoal/ coke and salt as required.

2

-

-

... More
Supplying and laying 25 mm X 5 mm G.l strip at ground as strip earth electrode, including connection/ terminating with G.l. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.l. nut bolt & spring washer spaced at 50mm).

60

-

-

... More
CABLE Supply, laying testing and commissioning of L.T. Al. XLPE armoured cable confirming to IS : 7098 Part - II as per direction of engineer-in-charge as per the description given below:

-

-

-

... More
3.5 C x 95 sq.mmPolycab/ finolex/ havells

50

-

-

... More
4 C x 50 Sqmm.Polycab/ finolex/ havells

30

-

-

... More
12 C x 2.5 Sqmm.(Cu) Polycab/ finolex/ havells

20

-

-

... More
4 C x 16 Sqmm.Polycab/ finolex/ havells

30

-

-

... More
CABLE END TERMINATION Supply, fixing, connection, testing and commissioning of double compression brass cable glands and crimping type lugs / sockets with necessary tools and equipments as specified in specifications and IS. The glands and lugs / sockets shall be suitable for cable size and type mentioned above. The job also includes, if necessary, supply and fixing of extension busbar of same material on circuit breaker / FSU or panel board terminal / connector to connect more than one no. of parallel cables or to connect higher size cable to lower size unit. The job also includes earthing the glands and armour of the cable with common earth bar or flexible copper mesh.

-

-

-

... More
3.5C x 95 sq.mm

2

-

-

... More
4 C x 50 Sqmm

8

-

-

... More
12 C x 2.5 Sqmm.

2

-

-

... More
4 C x 16 Sqmm.

4

-

-

... More
CABLE TRAY Supplying and installing of perforated G.I.sheet cable tray with necessary iron suspension supports, anchor fasteners etc. complete. Maximum height of suspension shall Not exceed 500 mm.Size of the tray is 40mm x 200mm x 40mm and 2mm thick.

15

-

-

... More
Providing and fixing Power wiring with 2 core x 1.5 sq.mm. PVC armoured copper cable for wiring pressure switches, etc. Including all required material and labour, terminations, etc. Complete.Polycab/ havells

60

-

-

... More
Supplying, installation testing and commissioning of the following . ‘C’ class MS Pipe as per IS:1239 above 150 nb IS 3589 for over ground pipes with flanged/ welded and with heavy clamps, hangers, brackets or pipe supports (all with flanged/welded joints) as required including pipe of shorter lengths, tapering connecting pieces, short or long bends, MS specials like sockets, union nuts, elbows, reducers, plugs, Tees, bends, etc. Complete to make the system operative as required by LFA / TAC authorities the pipes will have to be laid and fixed in trenches on walls, ceilings, into brick walls or RCC with lead anchor fastners. The work includes excavation in all types of soils and back filling and making holes in brick or RCC walls, slabs/ roofs and making good the damages by bringing to the original condition to the satisfaction of the engineer-in-charge and painting two coats of approved shade(Post office red)of enamel paint over a coat of approved primer for overheads pipes.Make- Jindal/TATA/Sail

-

-

-

... More
200mm

12

-

-

... More
150mm

12

-

-

... More
80 mm

6

-

-

6

-

-

... More
Providing, installing and commissioning C.I. flanged "Y" type Strainer with SS mesh, suitable flanges, nuts, bolts, gaskets etc. complete (ISI). Kartar/Zoloto/H sarker

-

-

-

... More
150 mm

2

-

-

... More
80 mm

1

-

-

... More
Supply and installation, testing and commissioning of double flanged Isolation Sluice valves conforming to IS 14846 tested to ISI marked ,PN 1.6 with CI body, bonnet & brass trim parts, & having necessary companion flanges, bolts, nuts, gasket packing, support and any other spares, including indicator for open and shut position Kartar/Zoloto/H sarker

-

-

-

... More
Size : 200 mmKartar/Zoloto/H sarker/Kirloskar

1

-

-

... More
Size : 150 mm Kartar/Zoloto/H sarker/Kirloskar

2

-

-

... More
Size : 80 mm Kartar/Zoloto/H sarker/Kirloskar

1

-

-

... More
Size : 50 mm Kartar/Zoloto/H sarker/Kirloskar

1

-

-

... More
Supply, installation, testing and commissioning of ci Butterfly valve of PN 1.6 rating with metal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required: Kartar/Zoloto/H sarker/Kirloskar

-

-

-

... More
Size : 150 mm

2

-

-

... More
Size : 80 mm

1

-

-

... More
Size : 50 mm

1

-

-

... More
NRV conforming to IS 5312 (swing type) or to API 594/598 (dual plate check type) with CI body & brass trim part, PN 1.6 having necessary companion flanges, CS hardwares. Gaskets, arrow indicating direction of flow, etc. complete. It shall be ISI Marked and approved make Kartar/Zoloto/H sarker/Kirloskar

-

-

-

... More
Size : 150 mm

3

-

-

... More
Size : 80 mm

1

-

-

... More
Size : 50 mm

1

-

-

... More
Supply, installation testing and commissioning pressure switch assembly with interlocking of pumps. Indfos/Danfos

5

-

-

... More
100 mm dial Pressure gauge with Syphon tubing, isolation valve & mounting accessories complete Range: 0 - 10 kg/sq.cm. H-Guru/G.Guru

7

-

-

... More
Supplying, installing, testing and commissioning of hydraulically operated Sprinkler control valve, with water motor gong bell and trims as required, pressure gauges, drain valves, ball valves, check valves, strainers etc. complete.as per NBC/LFA/direction of engineer-in-charge Size : 150 mm.HD/Viking/tyco

1

-

-

... More
SITC of water level indicator with panel, with probe & all control wiring to operate the system automatic/manual & shall prevent the pump from dry running as per NBC/LFA/ direction of engineer-in-charge

1

-

-

... More
Ball valve of 15 mm diaKartar/H sarker

10

-

-

... More
(A-5)TERRACE PIPING & ACCESSORIES Supply, installation, testing and commissioning of ci Butterfly valve of PN 1.6 rating with metal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required: Kartar/Zoloto/H sarker/Kirloskar

-

-

-

... More
Size : 150 mm

3

-

-

... More
Size: 50 mm

2

-

-

... More
NRV conforming to IS 5312 (swing type) or to API 594/598 (dual plate check type) with CI body & brass trim part, PN 1.0 having necessary companion flanges, CS hardwares. Gaskets, arrow indicating direction of flow, etc. complete. It shall be ISI Marked and approved make Size : 150 mm Kartar/H sarker/Zoloto

1

-

-

... More
Supplying, installation testing and commissioning of the following ‘C’ class MS Pipe as per IS:1239 for overhead pipes with flanges welded and with heavy clamps ,hangers, brackets or pipe supports (all with screwed/welded joints) as required including pipe of shorter lengths, tapering connecting pieces, short or long bends, MS specials like sockets, union nuts, elbows, reducers, plugs, Tees etc. Complete to make the system operative as required by LFA / TAC authorities the pipes will have to be laid and fixed in trenches on walls, ceilings, into brick walls or RCC with lead anchor fasteners. The work shall be to the satisfaction of the engineer-in-charge and painting two coats of approved shade(Post office red)of enamel paint over a coat of approved primer for overhead pipes.Make-TATA/Jindal/Sail

-

-

-

... More
Size : 150 mm

58

-

-

... More
Size : 50 mm

6

-

-

... More
(A-6)SPRINKLER SYSTEM Supplying, installation testing and commissioning of the following ‘C’ class MS Pipe as per IS:1239 for overhead pipes with fittings & flanges including pipe of shorter lengths, tapering connecting pieces, short or long bends, MS specials like sockets, union nuts, elbows, reducers, plugs, Tees etc. Complete to make the system operative as required by LFA / TAC authorities the pipes will have to be laid and fixed in trenches on walls, ceilings, into brick walls or RCC with lead anchor fasteners. The work shall be to the satisfaction of the engineer-in-charge and painting two coats of approved shade(Post office red)of enamel paint over a coat of approved primer for overhead pipes. Make-TATA/Jindal/Sail

-

-

-

... More
Size : 150 mm

75

-

-

... More
Size : 100mm

45

-

-

... More
Size : 80 mm

36

-

-

... More
Size : 65 mm

100

-

-

... More
Size : 50 mm

185

-

-

... More
Size : 40 mm

85

-

-

... More
Size : 32 mm

254

-

-

... More
Size : 25 mm

584

-

-

... More
Supplying, installing, testing and commissioning of standard response Sprinkler quartzoid bulb type with 15mm screwed end connection of 68 deg. C. temperature rating, K 80 and orifice shall Not be less than 3 mm. Pendent sprinkler HD/Viking/tyco

300

-

-

... More
Supplying, installing, testing and commissioning of test valve and complete accessories like tees,elbows flanges etc.as per NBC/LFA/direction of engineer-in-charge.

-

-

-

... More
Test assembly

6

-

-

... More
Test Valve (25 mm)

6

-

-

... More
Drain Pipe of 25 mm dia.Jindal/Tata

6

-

-

... More
Supply, installation, testing and commissioning of ci Butterfly valve of PN 1.6 rating with metal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required:

-

-

-

... More
Size : 150 mmKartar/Zoloto/H sarker

6

-

-

... More
50 mm (Drain Ball type valve for each riser / drain downtake)KartarZoloto/H sarker

6

-

-

... More
Supply & installation of approved make flow switch on sprinkler header on each floor, operating at 24-V with all accessories & hardwares as per NBC/LFA/direction of engineer-in-charge. Honeywell/Eq.

6

-

-

... More
SIGNAGES:-Providing and installing in position the following type of sign boards made out of 3mm thick flexyle photoluminescent based glow in dark sheeting with luminous properties enclosed in a weather proof Uvstabilized film with UV screen printing by imported links pasted over3 mm thick cast acrylic from front side with 6 mm thick acrylic, -20 to+80 deg C, Suitablefor indoor use, greenish yellow, glow visible upto 4-6 hr in total darkness.Make-Prolite/Bajaj

8500

-

-

... More
ANALOGUE ADDRESSABLE FIRE DETECTION AND ALARM SYSTEM Supply, Installation,Testing & Commisioning of Microprocessor based 2 loop fire alarm control panel with each loop capable of taking 99 devices, 8 line x 40 character alpha- numeric liquid crystal display .The panel shall be soft addressable type . The panel shall be able to give pin point location of all fire/fault conditions. Further, the panel must be able to automatically switch off respective control switches when ever any alarm is triggered. The panel shall have in built rectifier, Loop cards,provision for externel & internal printer(if required), L C D unit to indicate Fire/Fault Signal with address and analog output, built in printer to log all fire or fault events complete in all respects, integral SMF lead acid batteries with sealed cells of 24 V capable of running for a minimum of 8 hours with integral battery charger complete as required and as per specification. The fire alarm panel shall be suitable for software integration with BMS & PA system. Make:MORLEY IAS/Siemens/Bosch

1

-

-

... More
Supply, Installation,Testing & Commisioning of Analog Addressable Intelligent multi sensing detector with two inbuilt optical smoke & heatsensors with light angles as per NFPA style 7 wiring complete with base and inbuilt isolator as required.Make:MORLEY IAS/Siemens/Bosch

180

-

-

... More
Supply, Installation, testing and Commissioning of addressable manual call box made of polycarbonate with plastic break glass front and complete with monitor module MCB shall be recessed in wall . Make:MORLEY IAS/Siemens/Bosch

10

-

-

... More
SITC of addressable loop powered monitor module complete as required Make:MORLEY IAS/Siemens/Bosch

4

-

-

... More
Supply Installation, Testing & Commissioning of wall mounting loop powered addressable type hooter with strobe with all accessories as per specification.Make:MORLEY IAS/Siemens/Bosch

10

-

-

... More
Supplying, installing, testing and commissioning of 2C x 1.5 sq. mm, Twisted Pair PVC insulated FRLS Armored Cable with Accessories confirming to IS standards and specifications. The quoted rate shall includes of Acrylic Fire stop Sealant in the opening for cables passing through fire compartment walls of RCC floors, masonry walls to provide up to 2 hours fire rating. Make:-Polycab/ finolex/ havells/ RR Kabel

1800

-

-

... More
EMERGENCY EVACUATION SYSTEM/PUBLIC ADDRESS SYSTEM Supplying, installing, testing and commissioning of 6 Watt wall mounted speakers with built in line matching transformer, grill flush mounting type in side the utility rooms.Make:Honeywell/Bose/Bosch

60

-

-

... More
Supplying, installing, testing and commissioning solid state Compact 480w Power Amplifier The amplifier should be clean reliable audio for public address amplification. Line input less than 1 volt, unbalanced and line output less than 1 volt unbalanced.Make.: Honeywell/Bose/Bosch

2

-

-

... More
Supplying, installing, testing and commissioning of P.A. Controller 8 zone shall expandable up to 60 zones , with priority module micro processor based, mixing amplifier, with 6 zone for suitable selection module, power supply unit & goose neck micro phone etc.Make.: Honeywell/Bose/Bosch

1

-

-

... More
Supplying, installing, testing and commissioning of P.A. Call station of 8 zones with priority module micro processor based & goose neck micro phone etc shall be located in the reception / security for the announcement necessary communication cable/CAT 6 shall be considered from PA controller to call station .Make.: Honeywell/Bose/Bosch

1

-

-

... More
Supplying, installing, testing and commissioning of 19" Rack 650mm depth, 17 U high amplifier rack assembly made of aluminum channel equivalent to euro rack system, with side and rear panels made of 14 swg powder coated sheet steel front transparent persplexdoor and with rails, rollers & bearings. Fans shall provided at the top for ventilation side panels will be ventilated type. The rack shall be powder coated of approved color and spare 'U' shall be covered with blank panels.Make. Honywell/Bosch/Bose/eq.

1

-

-

... More
Supplying, installing, testing and commissioning of 2 runs of 40 strand and each of 0.2 mm thick, Twisted Pair PVC insulated FRLS unarmored Cable with Accessories confirming to IS standards and specifications. The quoted rate shall includes of Acrylic Fire stop Sealant in the opening for cables passing through fire compartment walls of RCC floors, masonry walls to provide up to 2 hours fire rating. Polycab/ finolex/ havells/ Eq.

670

-

-

... More
Supplying, installing, testing and commissioning approved make PVC FRLS conduits on ceiling / wall / floor etc. complete with accessories like, Junction boxes, Collars, Bends etc. 20mm dia.

600

-

-

... More
Supply,Installation, Testing and Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling only, having all hermetically sealed inverter type Scroll/Twin rotary Compressor(s), microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. The unit shall deliver the rated capacity at AHRI Conditions and work even at 49°C ambient temperature without tripping. The unit shall be suitable to work on 380-415 V, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. MS/GI powder coated stand with vibration isolation pads. The ODU shall have low noise condenser fans with external static pressure of the outdoor unit shall be more then 75 Pa to avoid hot air recirculation, auto address setting, automatic refrigerant charging,auto check function for connection error and complete with indoor and outdoor units with individual controller and with fittings etc. .The Unit should have free phase technology so that unit can work in case of phase reversal also without tripping of units.(Make: MITSUBISHI ELECTRIC /DAIKIN/O-General/Hitachi sigma model )

-

-

-

... More
12 HP

2

-

-

1

-

-

3

-

-

... More
20 HP

1

-

-

... More
Outdoor Connecting Kit

3

-

-

... More
Supply, Installation,Testing and Commissioning of following minimu capacity 4-way/ VRV Cassette Type Indoor ceiling mounted unit equipped with cord less remote , synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, drain pan, drain pump, cassette grill, insulation, necessary supports, vibration isolation etc, suitable for operation on 230 V ± 10%, 50 Hz single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire. All indoor Units should have force shut option to connect with fire alarm adaptor, so that the unit automatically stops in case or fire. The cooling capacity of indoor unit will be at air inlet conditions of 27 degree C DBT and 19 degree C WBT. (Make: MITSUBISHI ELECTRIC /DAIKIN/O-General/Hitachi sigma model )

-

-

-

... More
Cassette Unit

-

-

-

... More
2.06 TR

10

-

-

... More
2.56 TR

2

-

-

... More
3.3 TR

2

-

-

... More
4.12 TR

2

-

-

... More
4.6TR

2

-

-

... More
Supply, Installation,Testing and Commissioning of following minimum cpacity Wall Mounted Type Indoor unit equipped with cord less remote , synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, insulation, necessary supports, vibration isolation etc, suitable for operation on 230 V ± 10%, 50 Hz single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire. All indoor Units should have force shut option to connect with fire alarm adaptor, so that the unit automatically stops in case or fire. The cooling capacity of indoor unit will be at air inlet conditions of 27 degree C DBT and 19 degree C WBT. (Make: MITSUBISHI ELECTRIC /DAIKIN/O-General/Hitachi sigma model )

-

-

-

... More
Hi Wall Unit

-

-

-

... More
1.32 TR

4

-

-

... More
2.06 TR

2

-

-

... More
Supply & Installation of interconnecting following sizes of refrigerant copper pipe work of following outer diameter, insulated with 25mm thick closed cell electrometric Nitrile rubber tubular insulation between each set of indoor & outdoor units . The pipe dia upto 25 shall be soft seamless & above 25mm dia shall be hard seamless . All piping inside the room shall be properly fixed/supported with suitable size of clamp/ M.S. hanger and all external piping shall run in GI. cable tray etc. as reqd. Make of insulation-K Flex/Armacell/A-Flex Make of pipe-Rajco/Mandev

-

-

-

... More
Gas/Liquid line with 25mm thick insulation

-

-

-

... More
41.3mm

9

-

-

... More
34.9mm

22

-

-

... More
28.58mm

8

-

-

... More
22.2mm

47

-

-

... More
19.05mm

20

-

-

... More
15.88mm

246

-

-

... More
12.7mm

53

-

-

... More
9.52mm

178

-

-

... More
6.35mm

41

-

-

... More
Supply, Manufacturing, fixing,testing and commisioning of Alluminium ducting complete with supports,dampers etc.as per specifications. MakeTATA/SAIL/JINDAL

-

-

-

... More
24 G Sheet

300

-

-

... More
22 G Sheet

50

-

-

... More
Supply,installation,testing and commissioning of duct thermal insulation of Following Capacities , Make - Armacell/A flex/K flex . - with 25 mm thick Nitrile Rubber for indoor supply air ducting

30

-

-

... More
Accoustic Insulation 15 mm thick of Armasound open cell nitrile rubber

13

-

-

... More
Supply, erection, testing & commissioning of Aluminium powder coated grilles without VCD having flange all around.Make-Glenstorm/Airflow/Systemaire

5

-

-

... More
Supply, erection, testing & commissioning of Aluminium powder coated grilles with VCD having flange all around.Make-Glenstorm/Airflow/Systemaire

6

-

-

... More
Control & Transmission Wiring

-

-

-

... More
Supply Installation Testing and Commission of Control wiring of 2 core x 1.5 sqmm copper in suitable conduits between indoor and outdoor units (Make: Finolex/Polycab/Havells/RR kabel)

182

-

-

... More
Supply Installation Testing and Commission of PVC drain pipe with 6mm thick nitrile tube insulation. ( Supreme, Finolex)

-

-

-

25

-

-

91

-

-

17

-

-

... More
Design SITC of GI Slotted Tray for expose copper piping covered with GI sheet(22G) on terrace & in shaft if open.

-

-

-

... More
50mmx150mm X 50mm

105

-

-

... More
50mmx300mm X 50mm

20

-

-

... More
Gas Charging for the entire circuit(R410A)

140

-

-

... More
VI pads for ODU base

1

-

-

... More
Canvas connection for TFA units

5

-

-

... More
AIR HANDLING UNIT - 2 Stage Filtration- with VFD -Supply, Installation, testing and commissioning of factory fabricated double skin type Air Handling Units (BMS compatible) Floor Mounted Units with fire dampers for High Precision Zones as per specifications given below:-AHU Construction:- It shall be made out of min.0.6 mm pre-plasticized/pre-coated Galvanised steel sheet outside & 0.6 mm plain stainless steel sheet inside with 50 mm thick PUF insulation factory injected between them by injection moulding m/c, with density not less than 38 kg/Cum between them. Drain pan (made out of 1.25 mm stainless steel (SS Grade 304) sheet insulated with 19 mm think closed cell insulation(Nitrile/XLPE) & thermal break profile. Necessary foundation required & anti vibration pads shall be provided & cost for the same shall be included in this item. Supply Air Stream:- 1) Filter section consisting of pre filter and microvee/fine filter . Pre-filter section shall be with non woven synthetic media of 10 micron particle size with an efficiency of 90%, fine/microvee filter section will be with filters of non woven synthetic media of 3 micron particle size of efficiency 99%.2) BACKWARD CURVED PLUG/Centrifugal fans (with min. 70% efficiency) with blower motor, drive and flexible duct connection. The supply fan shall be provided with variable frequency drive and input / output signal compatible to BMS system.3) 6 row deep cooling coil 4) No Heating Coil Required 5) 50 mm Thick Puf Panel with Inner and outer Sheet of .6 mm thick both Side 6) Mixing Box comprising of damper & filter section.COIL- Copper tubes and Aluminium fins 12-13 fin./inch, Coil size shall be selected for air velocity of 500 ft/minute 12deg Celcius coil leaving temp & velocity across filters at 500 ft/minute. 7) 4.5 kW Heater bank.Motors shall be suitable for 415 ± 10% volts, 50 Hz, 3 phase AC supply & high efficiency(IE 3). Vibration isolation shall be as per specifications and as shown on the drawings. VFD:- VFD designed for HVAC applications with built-in PID controller, control panel (keypad & display) , IP-54 enclosure for use on standard BACKWARD CURVED PLUG/Centrifugal fans. The display should be in alpha-numeric characters and programming facility should be in user-friendly HVAC terminology. IP 20 Rated VFD to be placed inside the Stater Panel with IP 55 enclosure. Each VFD panel to be provided with digital display showing electrical parameters like voltage,current and power consumption.Sound level 72 db at the distance of 2 mtr.(maximum)Squirrel cage induction motors suitable for 415 ± 10% volts, 50 Hz, AC supply & high efficiency (IE-3 Efficiency), H.P of motor and coil shall be as per actual selection meeting other technical requirements. At the time of odering ahu total pressure loss as per friction method and ahu coil selection should be submitted for approval. Room design temp-19 deg celcius/RH-55%,INTAKE AIR DBT/RH-19 Deg. Cel./55%, Discharge air DBT/RH-12/96%. if any increase in head, no additional cost will be paid by the agency.4000 CFM / 17TR/6 RD CC / 110 mm TSP with Pre & Fine Filter - (Make:- VTS/ Trane/Systemair/Edgetech) For OT

1

-

-

... More
Supply & Installation of Planair Ceiling system with unidirectional airflow. Plenum unit, Holding structure & Top plenum are made of Aluminium Sheet 1.5mm thk. with aluminum extrusion frame with hepa filter with H-14 Grade having efficiency 99.97% down to0.3 micron.. in plenum level or in AHU level (AHU Level is preferred) The laminar flow system shall have such design with Diffuser : 2 layer monofilament precision woven polyester of uniform porosity with an open area of sufficient resistance to create laminar from diffusers face and integral lighting provides an illumination level in excess of 15000 Lux in operating area and 10000 Lux other electronic without flicker Size 2400mm x 2400mm x350mm complete as per the direction of engineer incharge. ( Make-Spectrum/AAF )

1

-

-

... More
P.H. WORK Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor CPVC pipes and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge In Ground floor

-

-

-

... More
In Ground floor

-

-

-

... More
20mm dia CPVC Pipe(Supreme/Ashirvad)

60

-

-

... More
25mm dia CPVC Pipe(Supreme/Ashirvad)

90

-

-

... More
32mm dia CPVC Pipe(Supreme/Ashirvad)

20

-

-

... More
50mm dia CPVC Pipe(Supreme/Ashirvad)

100

-

-

... More
In First floor

-

-

-

... More
20mm dia CPVC Pipe(Supreme/Ashirvad)

40

-

-

... More
25mm dia CPVC Pipe(Supreme/Ashirvad)

60

-

-

... More
32mm dia CPVC Pipe(Supreme/Ashirvad)

10

-

-

... More
40mm dia CPVC Pipe(Supreme/Ashirvad)

20

-

-

... More
50mm dia CPVC Pipe(Supreme/Ashirvad)

10

-

-

... More
In Second floor

-

-

-

... More
20mm dia CPVC Pipe(Supreme/Ashirvad)

20

-

-

... More
25mm dia CPVC Pipe(Supreme/Ashirvad)

30

-

-

... More
32mm dia CPVC Pipe(Supreme/Ashirvad)

5

-

-

... More
40mm dia CPVC Pipe(Supreme/Ashirvad)

20

-

-

... More
50mm dia CPVC Pipe(Supreme/Ashirvad)

10

-

-

... More
In Third floor

-

-

-

... More
20mm dia CPVC Pipe(Supreme/Ashirvad)

20

-

-

... More
25mm dia CPVC Pipe(Supreme/Ashirvad)

30

-

-

... More
32mm dia CPVC Pipe(Supreme/Ashirvad)

10

-

-

... More
40mm dia CPVC Pipe(Supreme/Ashirvad)

30

-

-

... More
50mm dia CPVC Pipe(Supreme/Ashirvad)

10

-

-

... More
In Fourth floor

-

-

-

... More
20mm dia CPVC Pipe(Supreme/Ashirvad)

20

-

-

... More
25mm dia CPVC Pipe(Supreme/Ashirvad)

30

-

-

... More
32mm dia CPVC Pipe(Supreme/Ashirvad)

10

-

-

... More
40mm dia CPVC Pipe(Supreme/Ashirvad)

30

-

-

... More
50mm dia CPVC Pipe(Supreme/Ashirvad)

10

-

-

... More
In Fifth floor

-

-

-

... More
40mm dia CPVC Pipe(Supreme/Ashirvad)

40

-

-

... More
50mm dia CPVC Pipe(Supreme/Ashirvad)

100

-

-

... More
Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge.

-

-

-

... More
250mm thick wall -In Ground floor

15

-

-

... More
250mm thick wall -In First floor

12

-

-

... More
250mm thick wall -In Second floor

8

-

-

... More
250mm thick wall -In Third floor

8

-

-

... More
250mm thick wall -In Fourth floor

8

-

-

... More
Supplying all materials, labour, T&P and cutting holes in RCC floor,roofs slabs,chajjas etc. including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge.

-

-

-

... More
In Ground floor

10

-

-

... More
In First floor

8

-

-

... More
In Second floor

5

-

-

... More
In Third floor

5

-

-

... More
In Fourth floor

5

-

-

... More
Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking GI/ PVC pipes and making good the damages as per the direction of the Engineer in charge.

-

-

-

... More
In Ground floor

150

-

-

... More
In First floor

100

-

-

... More
In Second floor

50

-

-

... More
In Third floor

50

-

-

... More
In Fourth floor

50

-

-

... More
Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI pipes and fittings including making good the damages etc all complete as per PH specification and direction of the Engineer in charge

-

-

-

... More
250mm to 375mm thick wall-In GF to 4th floor.

160

-

-

... More
Supplying all materials, labour, T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge

-

-

-

... More
15mm dia CP Long Body Bib cock (Con-CHR-107KN Jaquar make)

13

-

-

... More
15mm dia CP two in one bib cock (Con-CHR-041KN Jaquar make)

28

-

-

... More
15mm dia CP Bib cock (Con-CHR-047KN Jaquar make)

4

-

-

... More
15mm dia CP Health faucet (Con-ALD-MCH-573 Jaquar make)

28

-

-

... More
15mm dia CP angle stop cock (Con-CHR-053KN Jaquar make)

77

-

-

... More
20mm dia CP consealed stop cock(Con-CHR-083KN Jaquar make)

6

-

-

... More
15mm dia CP Urinal Flush Valve(Jaquar)No.FLV-CHR-1093

5

-

-

... More
15mm dia CP Pillar cock (Con-CHR-011KN Jaquar make)

40

-

-

... More
15mm CP revolving shower (Jaquar)CON-CHR-209KN

4

-

-

... More
25mm dia Brass or gun metal fullway valve(Shakti or equivalent make)

22

-

-

... More
32mm dia Brass or gun metal fullway valve(Shakti or equivalent make)

7

-

-

... More
40mm dia Brass or gun metal fullway valve(Shakti or equivalent make)

4

-

-

... More
50mm dia Brass or gun metal fullway valve(Shakti or equivalent make)

8

-

-

... More
15mm CP Extension piece

128

-

-

... More
125mm CP grating

80

-

-

... More
15mm size C.P. flange

128

-

-

... More
Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.

-

-

-

... More
110mm U-PVC SWR Pipe (Ashirvad/Supreme Make)

650

-

-

... More
110mm U-PVC door bend(Ori Plast/Finolex/Supreme Make)

40

-

-

... More
110mm U-PVC Plain tee(Ori Plast/Finolex/Supreme Make)

70

-

-

... More
110mm U-PVC D/Jn door(Ori Plast/Finolex/Supreme Make)

16

-

-

... More
110mm U-PVC offset without ear(Ori Plast/Finolex/Supreme Make)

16

-

-

... More
110mm U-PVC Plain bend(Ori Plast/Finolex/Supreme Make)

35

-

-

... More
110mm U-PVC Cowl(Ori Plast/Finolex/Supreme Make)

8

-

-

... More
110mm U-PVC ‘P’ Trap(Ori Plast/Finolex/Supreme Make)

72

-

-

... More
110mm U-PVC S/Jn door(Ori Plast/Finolex/Supreme Make)

30

-

-

... More
110mm U-PVC Door tee(Ori Plast/Finolex/Supreme Make)

32

-

-

... More
110mm U-PVC Socket(Ori Plast/Finolex/Supreme Make)

100

-

-

... More
Supplying all materials, labour, T&P and cutting of R.C.C chajja for taking H.C.I pipes and making good the damages etc all complete as per P.H.Specification and direction of the Engineer in charge

-

-

-

... More
Cutting of R.C.C chajja for taking H.C.I pipes

-

-

-

... More
In Ground floor

7

-

-

... More
In First floor

6

-

-

... More
In Second floor

5

-

-

... More
In Third floor

5

-

-

... More
In Fourth floor

5

-

-

... More
Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan conforming to IS:2556-part-3-2004) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x 30mm footrest, fixing 100mm dia HCI ‘P’ or ‘S’ trap (with/without 50mm dia horn) for water closet squatting pan including jointing the trap with pan in cement mortar (1:1), cutting the floor and mending good the damages etc all complete as per specification and direction of the Engineer in charge

-

-

-

... More
580mm size Orissa pan(Parrywear/Hindware/Neycer)

4

-

-

... More
Supplying all materials, labour T&P and and fixing 12.50 liters/10 liters capacity low level flushing cistern with a pair of cast iron or M.S. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle,unions and couplings for connection with inlet, outlet and overflow pipes, 32mm dia CP long flush bend, 15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connceting the inlet pipe with suupply main , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge

-

-

-

... More
10 ltr. Capacity pvc L.L. cistern with 32mm. Dia CP long flush bend ( Slimline-white-Parryware make )

22

-

-

... More
Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet (European type W.C pan) with integral ‘P’or ‘S’ trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1), fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer in charge

-

-

-

... More
E.W.C. with ‘P’ trap plain with seat cover.(Parrywear/Hindware/Neycer)

18

-

-

... More
One piece commod(Hindware)ELEMENT Cat No.92084.

9

-

-

... More
Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps conforming to IS:2556-part-4-2004 with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of 15mm dia nominal bore(Plaza make), fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste(Plaza make), etc all complete as per specification and direction of the Engineer in charge

-

-

-

... More
550mmx400mm size wash hand basin with pedestral(Parrywear/Hindware/Neycer)

17

-

-

... More
Under Counter basin(560x450)Hindware-No.10095

12

-

-

... More
Halfpedestal basin(560x450)Hindware No.91049+91115

10

-

-

... More
Matrix Set -1 (WB 65 x 35 with one pair mounting brackets, EWC & Cistern complete with fittings & seat cover, one no hinged rail 76 cm and five nos of grab rails 60 cm)(Hindware)No.7002

1

-

-

... More
Supplying all materials, labour, T&P and fixing glazed earthenware squatting plate of size 600mmx350mm with integral longitudinal flushing pipe including embedding the plate in 25mm cement mortar (1:8) laid over 150mm cement concrete (1:5:10) using 40mm hard granite metal all complete as per specification and direction of the Engineer in charge

-

-

-

... More
Fixing of squatting urinal (Parrywear/Hindware/Neycer)

2

-

-

... More
Supplying all materials, labour, T&P and fixing bowl pattern urinal including connecting the urinal with waste pipe by means of white lead mixed with chopped hemp etc all complete as per specification and direction of the Engineer in charge.

-

-

-

... More
Fixing of Half stall urinal (Parrywear/Hindware/Neycer)

5

-

-

... More
15mm dia C.P.Urinal Spreader

5

-

-

... More
32mm dia CP Dome Waste

5

-

-

... More
Supplying all materials, labour, T&P and fixing wash kitchen sink/laboratory sink with cast iron or M S brackets painted white including cutting holes in walls and making good the damages etc all complete as per specification and direction of the Engineer in charge

-

-

-

... More
600x450x250 mm stainless steel kitchen sink (Jayna make)

9

-

-

... More
Supplying all materials, labour, T&P and fixing mirror of superior glass conforming to IS:3438-1996 mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in charge

-

-

-

... More
600mm x 450mm size B.E mirror

17

-

-

... More
Big size Mirror-12x0.60x0.75=

5.4

-

-

... More
Design Mirror(Parryware)

10

-

-

... More
Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rails complete fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge

-

-

-

... More
600x125mm plate glass shelf with CP guard rails

36

-

-

... More
Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge

-

-

-

... More
25mmx600mm long CP towel rail

39

-

-

... More
CP towel ring

25

-

-

... More
Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge

-

-

-

... More
CP soap holder

39

-

-

... More
CP soap Dispenser(Jaquar)ACN-CHR-1135N

10

-

-

... More
Supplying all materials, labour, T&P and providing granite in wall, treads and landing on 25mm thick bed of cement mortar 1:1 (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge. upto 0.10 sqm.

-

-

-

... More
In Ground floor

18.9

-

-

... More
In First floor

13.05

-

-

... More
Supplying all materials, labour, T&P and fixing Kodappa tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge

-

-

-

... More
In Ground floor

5.4

-

-

... More
In First floor

10.8

-

-

... More
Supplying all materials, labour, T&P and providing and filling sand including watering, ramming and compacting, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge

-

-

-

... More
In Ground floor

12.67

-

-

... More
Supplying all materials, labour, T&P and providing cement concrete (1:4:8) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge

-

-

-

... More
In Ground floor

4.22

-

-

... More
Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge

-

-

-

... More
In Ground floor

4.22

-

-

... More
In First floor

5.19

-

-

... More
In Second floor

3.96

-

-

... More
In Third floor

1.78

-

-

... More
In Fourth floor

1.78

-

-

... More
Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge

-

-

-

... More
In Ground floor

157.61

-

-

... More
In First floor

162.75

-

-

... More
In Second floor

55.02

-

-

... More
In Third floor

74.13

-

-

... More
In Fourth floor

74.13

-

-

... More
Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) with neat cement punning on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge

-

-

-

... More
In First floor

79.65

-

-

... More
In Second floor

22.15

-

-

... More
In Third floor

33.64

-

-

... More
In Fourth floor

33.64

-

-

... More
Providing & applying water proofing treatment (Two Component glass fibre reinforced specially formulated acrylic modified, cementitious elastic coating system) using Sika Top Seal 109 hi & Sika Fab-1 or equivalent (glass fibre cloth) @ 3Kg/Sq.mtr before one coat of Sika Top Seal 109 hi or equivalent Primer @ 200 gm/Sq.mtr over the cleaned RCC Horizontal Surface & Outer retaining wall etc including the cost of all materials, cost of labour, conveyance, taxes, T&P, etc. all complete as per the direction of Engineer-in-Charge.

-

-

-

... More
In First floor

79.65

-

-

... More
In Second floor

22.15

-

-

... More
In Third floor

33.64

-

-

... More
In Fourth floor

33.64

-

-

... More
Supplying all materials, labour, T&P and providing and fixing Vitrified tiles in floors, treads or steps and landing on 25mm thick bed of cement mortar (1:1) ( 1 cement : 1 sand ) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge ( Vitrified floor tiles of premium grade having thickness 7mm to 8mm conforming to IS 13755 of size Kajaria/Somany/Johnson tile 60cmx60cm special printed series to be pre-approved by the Engineer-in-charge )

-

-

-

... More
In Ground floor

42.23

-

-

... More
In First floor

51.79

-

-

... More
In Second floor

10.35

-

-

... More
In Third floor

17.75

-

-

... More
In Fourth floor

17.75

-

-

... More
Supplying all materials, labour, T&P and providing and fixing porcelain glazed tiles in dado skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge( Vitrified mat finish wall tiles of premium grade having thickness 6.5mm to 6.7mm conforming to IS 13753 of size Kajaria/Somany/Johnson tile 60cmx30cm special plain / printed series to be pre-approved by the Engineer-in-charge )

-

-

-

... More
In Ground floor

157.61

-

-

... More
In First floor

162.75

-

-

... More
In Second floor

55.02

-

-

... More
In Third floor

74.13

-

-

... More
In Fourth floor

74.13

-

-

... More
Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 650kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter. of make Rajshri Plastiwood/ Alstone/Aramstrong or euivalant as per direction of Engineer-in-charge.

68.36

-

-

... More
Factory made Solid WPC door frame of size 90mmx45mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification. of make Rajshri Plastiwood/ Alstone/ Aramstrong or euivalant as per direction of Engineer-in-charge.

204.75

-

-

... More
Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) Pure Chill 80 PSS UV of size 750x570x1350mm height with water storage capacity 80 liters along with 2 nos of faucets 1 for cold water and 1 for normal water including a flow of 1.5 ltr per minute etc all complete as per approved drawing,specification and direction of the Engineer in charge.

5

-

-

... More
External P.H.Works

-

-

-

... More
Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, Fly ash brickwork in cement mortar (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size CI grating etc all complete as per approved drawing, specification and direction of the Engineer in charge

-

-

-

... More
Inside size 250mmx250mm

14

-

-

... More
Supplying all materials, labour, T&P and constructing inspection chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class Fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips, 12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge

-

-

-

... More
Inside size 760mmx760mmx460mm

18

-

-

... More
Fitting and fixing RCPC cover (18")

18

-

-

... More
Supplying all materials, labour, T&P and constructing man hole chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class K.B brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge

-

-

-

... More
Man hole chamber Inside size 910mmx910mmx910mm

6

-

-

... More
Fitting and fixing RCPC cover (18")

6

-

-

... More
Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and 1st class K.B brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Brick masonry soakway pit 1.20m dia x 2.00m deep

2

-

-

... More
Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class–3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge.

-

-

-

... More
110mm dia u-pvc pipe alround concrete

94

-

-

... More
160mm dia u-pvc pipe alround concrete

50

-

-

... More
Construction of 120000 Liters RCC Under ground Reserver of Inside size- 12.00 X 6.50 X1.80m

-

-

-

... More
Earth work in excavation of foundation in all kinds of soil within 50 mtr initial lead and 1.5mtr initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3 mtr in depth and as per direction of the Engineer in charge.

171.81

-

-

... More
-do- with Ist additional depth of 1.50 m over the initial lead and lift

34.36

-

-

... More
Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer in charge.

30.49

-

-

... More
Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge

20.33

-

-

... More
Supplying all materials, labour, T&P and providing cement concrete (1:1½:3)with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge

-

-

-

... More
Base slab 1x13.20x7.70x.30

30.49

-

-

... More
Roof Slab - 1x12.60x7.10x0.20

17.89

-

-

... More
Beam -

26.03

-

-

... More
Supplying all materials, labour, T&P and providing M.S.Reinforcement for RCC work including cutting, banding, binding, straightening and trying the grills and placing in position including cost of binding wire 18 to 20 gage.

26.03

-

-

... More
Supplying all materials, labour,T&P and providing 6mm thick cement plasster (1:4) over CC work including watering curring and conveyance of all materials to site.

183.4

-

-

... More
Supplying all materials, labour, T&P and providing cement punning including watering, curring and conveyance of all materials to site.

183.4

-

-

... More
Supplying and fitting and fixing stainless steel 34 grade in said rail using 5mm dia 2mm thick circular pipe and lalustrade 32mmx32mmx2mm at the rate of mtr.Center to center and square pipe 32x32x2mm below including welding with stanless steel elect rod and fixing with necessary accessories etc.complete as per direction of the Engineer-in-charge.

120

-

-

... More
Providing fitting and fixing RCPC cover etc complete as per direction of Engineer-in-charge

2

-

-

... More
Supplying all materials, labour, T&P and providing shoring and shuttering foundation trenches, pits etc with close wooden planks or sheets shuttering etc all complete as per direction of the Engineer in charge.

70.92

-

-

... More
De-watering

100

-

-

... More
Providing & applying water proofing treatment (Two Component glass fibre reinforced specially formulated acrylic modified, cementitious elastic coating system) using Sika Top Seal 109 hi & Sika Fab-1 or equivalent (glass fibre cloth) @ 3Kg/Sq.mtr before one coat of Sika Top Seal 109 hi or equivalent Primer @ 200 gm/Sq.mtr over the cleaned RCC Horizontal Surface & Outer retaining wall etc including the cost of all materials, cost of labour, conveyance, taxes, T&P, etc. all complete as per the direction of Engineer-in-Charge.

184.05

-

-

... More
Construction of 20000 Liters RCC Over head Tank of Inside size- 6.00 X 3.00 X1.50m- In Fifth floor.(For Domestic purpose)

-

-

-

... More
Supplying all materials, labour, T&P and providing cement concrete (1:1½:3)with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge

-

-

-

... More
Base Slab - 1x6.50x3.50x0.15

3.41

-

-

... More
Top Slab - 1x6.50x3.50x0.125

2.84

-

-

... More
Column-

10.51

-

-

... More
Supplying all materials, labour, T&P and providing M.S.Reinforcement for RCC work including cutting, banding, binding, straightening and trying the grills and placing in position including cost of binding wire 18 to 20 gage.

10.51

-

-

... More
Supplying all materials, labour,T&P and providing 6mm thick cement plasster (1:4) over CC work including watering curring and conveyance of all materials to site.

52.2

-

-

... More
Supplying all materials, labour, T&P and providing cement punning including watering, curring and conveyance of all materials to site.

52.2

-

-

... More
Supplying and fitting and fixing stainless steel 34 grade in said rail using 5mm dia 2mm thick circular pipe and lalustrade 32mmx32mmx2mm at the rate of mtr.Center to center and square pipe 32x32x2mm below including welding with stanless steel elect rod and fixing with necessary accessories etc.complete as per direction of the Engineer-in-charge.

60

-

-

... More
Providing fitting and fixing MS cover made out of MS angle and sheet duly welding and fixing with frame and hinges along with locking arrangement of size 60cmx60cm etc complete as per direction of Engineer-in-charge

40

-

-

... More
Providing & applying water proofing treatment (Two Component glass fibre reinforced specially formulated acrylic modified, cementitious elastic coating system) using Sika Top Seal 109 hi & Sika Fab-1 or equivalent (glass fibre cloth) @ 3Kg/Sq.mtr before one coat of Sika Top Seal 109 hi or equivalent Primer @ 200 gm/Sq.mtr over the cleaned RCC Horizontal Surface & Outer retaining wall etc including the cost of all materials, cost of labour, conveyance, taxes, T&P, etc. all complete as per the direction of Engineer-in-Charge.

54.85

-

-

... More
(Sinking of 150mm size tube well through hand boring( water jet) method) Suplying all materials, labour, T&P and setting up boring equipments including erection of suitable staging for installation of the required size of tube well, dismantling and removing the same after complection of the work, including transportation of the boring equipments, cleaning and levelling the site, excavation of mud pit, channels etc, levelling of site all complete as per direction of Engineer in charge

2

-

-

... More
Supplying all labour, T&P and transporting the boring pipes, top casing, grouting pipes, PVC pipes and fittings, PVC well screens, cement, bentinite and gravels etc to the worksite including loading and unloading etc all complete as per direction of the Engineer in charge.

2

-

-

... More
Supplying all labours, T&P and drilling pilot bore not less than 102mm dia, without casing pipes in all kind of soils and rocks for the following depths excluding supply of necessary boring pipes including supply of necessary cutting equipments, extra sockets ( whenever required) etc and withdrawing the boring pipes, washing and keeping the bore logging if required all complete as per direction of Engineer in charge Drilling pilot bore from 0 to 360 metres

180

-

-

... More
Supplying all labour, T&P and reaming the pilot bore to the following sizes and depth without casing pipes including withdrawing the boring pipes, washing the bore by means of pipe cylinder etc all complete as per direction off Engineer in charge. Reaming 100mm to 150mm dia from 0-360 mtr

180

-

-

... More
Reaming 150mm to 200mm dia from 0-360 mtr

180

-

-

... More
Reaming 200mm to 300mm dia from 0-360 mtr

180

-

-

... More
Supplyimg all labour, T&P and jointing materials & lowering the 300mm dia top casing pipes into the position and removing the same after all complete as per direction of Engineer in charge From 0-360 mtr

2

-

-

... More
Supplying all labour, T&P and jointing materials and lowering the pvc casing pipes, fittings and well screens in position, including fitting and fixing of centraliser, cutter plug and washing the bore all complete as per direction of Engineer in charge 150mm dia PVC casing pipe from 0 to 360 metres

180

-

-

... More
Cost of 150 mm dia PVC ASTM pipe(sch-80)

181.6

-

-

... More
Cost of 150mm dia Slott Cutting

30

-

-

... More
150 mm dia C.I.end/top cutter plug

4

-

-

... More
Cost & Conveyance of bentonite powder

20

-

-

... More
Supplying all materials, labour, T&P and packing the bore with washed gravel of river shingles of required size and specification around the well screen and pipe etc all complete as per the direction off the Engineer in charge. Labour charges

4

-

-

... More
Cost and Conveyance of gravel

4

-

-

... More
Supplying all materials, labour, T&P and packing the bore with river sand over the gravel pack all complete as per the direction of the Engineer in charge. Labour charges

3

-

-

... More
Cost and Conveyance of sand

3

-

-

... More
Supplying all labour, T&P including developing the tube well with compressor ( supplied by contractor ) continuiously worked till clear & adequate discharge is obtained from the tube well including supply and use of necessary equipments and labour as per direction of the Engineer in charge. Labour charges

2

-

-

... More
Supply all materials, labour, T&P and providing,fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1phase line voltage ranging from 320 volt to 450 volt conforming to IS:8034/89 with following specifications with suitable control pannel, jointing with GI/PVC/HDPE pipes electrification, testing,commissioning,trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge. a) 2 H.P three phase 3 stage head range 30 to 54 metres, discharge 155 to 110 L.P.M with outlet dia of 32mm Submersible Pump & Motor.

-

-

-

... More
2 H.P three phase 3 stage head range 30 to 54 metres, discharge 155 to 110 L.P.M with outlet dia of 32mm Submersible Pump & Motor.

2

-

-

... More
DOL control panel

2

-

-

... More
2.50sqmm cable

150

-

-

... More
32mm dia steel short piece

4

-

-

... More
Steel rope with cover

70

-

-

... More
Well cap suitable for 8" bore well

2

-

-

... More
50mm size CI bracket

4

-

-

... More
20mm dia rigid UPVC pipes

150

-

-

... More
32mm dia rigid PVC ASTM pipes

150

-

-

... More
40mm dia HDPE pipe

70

-

-

... More
Labour charges for lowering of submesible pumpset with pipes and cables etc. with testing and commissioning at site.

2

-

-

... More
Supplying all materials, labour, T&P and constructing Bore well protection chamber of the inside size 650x650x1000hight with cement concrete (1:3:6) using 40mm size hard granite metal on foundation, 1st class Fly ash brickwork in cement mortar (1:3), with base cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:4) inside and outside, R.C.C cover slab in (1:1.5:3) using 12mm size h.g chips, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge.

2

-

-

... More
Supply all materials, labour, T&P and providing,fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1phase line voltage ranging from 320 volt to 450 volt conforming to IS:8034/89 with following specifications with suitable control pannel, jointing with GI/PVC/HDPE pipes electrification, testing,commissioning,trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge.

-

-

-

... More
2HP Three Phase 5 stage Horizental submersible pump set.

1

-

-

... More
DOL control panel

1

-

-

... More
50mm S. S. Nipple, S. S. bolt & clips

2

-

-

... More
50mm M. S. Clamp, Bend, Socket & 200mm M. S. well cap

1

-

-

... More
2.50mm Sqm Submersible flat cable

50

-

-

... More
Labour charges for lowering, testing, commissioning & transportation to site etc.

1

-

-

... More
Construction 1 nos 200 users RCC Septic tank

-

-

-

... More
Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-Charge.

107.14

-

-

... More
-do- with Ist extra lift of 1.5 mtr over the initial lead and lift

71.19

-

-

... More
Supplying all materials,labour ,T&P and filling in foundation and plinth with sand well watered and rammed including cost, conveyance of all materials to work site ,payment of royalty,taxes etc. all complete as per direction of the Engineer-in -charge

11.47

-

-

... More
Supplying all materials, labour, T&P and providing cement concrete ( 1:4:8 ) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge.

9.04

-

-

... More
Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge

4

-

-

... More
Supplying all materials, labour, T&P and providing cement concrete (1:1:5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge

-

-

-

17.2

-

-

... More
Top slab

7.13

-

-

19.34

-

-

... More
Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge

-

-

-

... More
In ground floor

19.34

-

-

... More
Supplying all materials,labour,T&P and providing 6mm thick cement plaster(1:4) on RCC work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge.

75.93

-

-

... More
Supplying all materials,labour,T&P and providing 12mm CP (1:4) with cement punning on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge.

8.1

-

-

... More
Supplying all materials, labour, T&P and providing,fitting and fixing 100mm x 100mm x 100mm SW Tee in wall including filling the recess with cement concrete (1:3:6) with 12mm size h.g chips all complete including watering, curing, conveyance of all materials to worksite, payment of royalty all complete as per specification and direction of the Engineer in charge

2

-

-

... More
Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge.

12

-

-

... More
Supplying all materials, labour, T&P and fitting and fixing RCPC cover of heavy duty etc. all complete as per specification and direction of the Engineer in charge.

2

-

-

... More
Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge

58.85

-

-

... More
OXYGEN SYSTEM

-

-

-

... More
Oxygen Gas Outlet Point with Adopter . Make-Medinited/Unistar/Unitech

67

-

-

... More
SITC for Oxygen Outlets as Per standards, Terminal units shall be capable of single-handed insertion and removal of the medical gas probe. The wall mounted first fix assembly shall consist of brass pipeline termination block with copper stub pipe secured between a back plate and a gas specific plate to allow limited radial movement of the copper stub to align with the pipeline. The gas specific plate shall be permanently fixed to the backplate etc. complete as required. Oxygen Manifold 10 + 10 With Tail Pipe & Nrv Make-Medinited/Unistar/Unitech

1

-

-

... More
SITC of oxygen manifold of Size (10 working + 10 Standby) for Indian type bulk cylinders, high pressure copper annealed tail pipes complete with middle frame, chains for individual bulk oxygen cylinder, NRV's and 20 nos. pig tail pipes. it should be suitable to withstand a working pressure of 145 kg/cm2 and should be tested at 300 kg/cm2. etc. complete as required. Oxygen Manifold 3+3 Emergency With Regulator Make-Medinited/Unistar/Unitech

1

-

-

... More
SITC of oxygen manifold of Size (3 working + 3 Standby) for Indian type bulk cylinders, high pressure copper annealed tail pipes complete with middle frame, chains for individual bulk oxygen cylinder, NRV's and 6 nos. pig tail pipes. it should be suitable to withstand a working pressure of 130 kg/cm2 and should be tested at 300 kg/cm2. etc. complete as required.Oxygen Semi-Control Panel Make-Medinited/Unistar/Unitech

1

-

-

... More
SITC of Semi-Automatic oxygen control panel. Visual indication of the manifold is provided by 3 guages within control panel, Indicating Pressure of the right & Left hand bank and the supply pressure from control panel to distribution system with sensing faciliteies to provide visual signals na other anciliary services such as heaters. Pannel should be fitted with audio alarm indication for changeover of empty cylinder. The entire manifold will be hydraulically tested at 130 Kg/Cm2 pressure, duly degreased foroxygen Service, and supplied in sealed cover, ready for assembly at site etc. complete as required.(Note : Excluding Supply of cylinder.( Make-Medinited/Unistar/Unitech)Oxygen Flow Meter With Humdifire Bottle Make-Medinited/Unistar/Unitech

55

-

-

... More
SITC for Oxygen flowmeter complete with humidifier bottle, The flow meter must be constructed with chromium plated brass body, extremely robust, to take care of the day to day usage demand. Flow meter cartridge type knob : easy to maintain, offers optimum adjustment quality and superior designing and engineering to provide high level of accuracy, with no significant affect from restrictions caused by down-stream equipments. The flow meters should be 0-15 LPM range for oxygen. etc complete as required.

-

-

-

... More
VACCUM SYSTEM

-

-

-

... More
Vaccum Gas Outlet Point with Adopter Make-Medinited/Unistar/Unitech

30

-

-

... More
SITC for Vacuum outlets as per standards, Terminal units shall be capable of single-handed insertion and removal of the medical gas probe. The wall mounted first fix assembly shall consist of brass pipeline termination block with copper stub pipe secured between a back plate and a gas specific plate to allow limited radial movement of the copper stub to align with the pipeline. The gas specific plate shall be permanently fixed to the backplate, etc. complete as required.

-

-

-

... More
Ward Vaccum Regulator with 600ml jar Make-Medinited/Unistar/Unitech

30

-

-

... More
Vaccum Pump Type , Cap:- 5 Hp • 5 HP motor with suitable starter, mounted on base frame, complete with wiring, switched, interconnecting pipes and isolation valve(s). • The vacuum pressure isn’t exceeding 29.4 in Hg with flow volume 60 cfm. Make :- Anest Iwata

2

-

-

... More
Vaccum Reciver , Cap:-500 Ltr The receiver assembly shall be fitted with a pressure safety valve capable of passing the maximum flow output of the compressor at 10% receiver overpressure. The receiver shall be further protected by a safety pressure relief valve and include a pressure gauge. Make :- Anest Iwata

1

-

-

... More
Pressure Filter

2

-

-

... More
COMPRESSED AIR SYSTEM

-

-

-

... More
Air Gas Outlet Point with Adopter Make-Medinited/Unistar/Unitech

30

-

-

... More
Compressed M.Air- 4 Bar outlets as Per standards , Terminal units shall be capable of single-handed insertion and removal of the medical gas probe. The wall mounted first fix assembly shall consist of brass pipeline termination block with copper stub pipe secured between a back plate and a gas specific plate to allow limited radial movement of the copper stub to align with the pipeline. The gas specific plate shall be permanently fixed to the backplate, etc. complete as required.

-

-

-

... More
Air Compressor , Cap:- 7.5 Hp • Oil free Reciprocating Base Mounted two stage oil free with three phase Motor Compressor. • 7.5HP electric motor Base mounted • Maximum pressure 8.5 of minimum 24.5 cfm. • Other hardware complete with wiring, switches, interconnecting pipes and isolation valve(s). Make :- Anest Iwata

2

-

-

... More
Air Receiver , Cap:-500 Ltr The receiver assembly shall be fitted with a pressure safety valve capable of passing the maximum flow output of the compressor at 10% receiver overpressure. The receiver shall be further protected by a safety pressure relief valve and include a pressure gauge. Make :- Anest Iwata

1

-

-

... More
Air Dryer ,Cap:-40 CFM , Make-Trident/ Sumit Dryer

1

-

-

... More
Pressure Regulator

4

-

-

... More
NITRUS SYSTEM

-

-

-

... More
Nitrus Gas Outlet Point Make-Medinited/Unistar/Unitech

2

-

-

... More
Nitrous Oxide outlets as Per standards, Terminal units shall be capable of single-handed insertion and removal of the medical gas probe. The wall mounted first fix assembly shall consist of brass pipeline termination block with copper stub pipe secured between a back plate and a gas specific plate to allow limited radial movement of the copper stub to align with the pipeline. The gas specific plate shall be permanently fixed to the backplate, etc. complete as required.Nitrus Manifold 2 + 2 With Tail Pipe & Nrv Make-Medinited/Unistar/Unitech

1

-

-

... More
(2working + 2 Standby) size of N2O manifold complete with middle frame, chains, NRV's 4 nos. pig tail pipes, Manifold should have high pressure copper annealed tail pipes with one end having brass bull nose suitable for Nitrous Oxide cylinders and other end suitable for Manifold non- return Valves. Each manifold will have one terminal header and a NPT connection for the Automatic Control Panel. etc. complete as required.Nitrus Manifold 1+1 Emergency With Regulator Make-Medinited/Unistar/Unitech

1

-

-

... More
(1 working + 1 Standby) size of N2O manifold complete with middle frame, chains, NRV's 2 nos. pig tail pipes, Manifold should have high pressure copper annealed tail pipes with one end having brass bull nose suitable for Nitrous Oxide cylinders and other end suitable for Manifold non- return Valves. Each manifold will have one terminal header and a NPT connection for the Automatic Control Panel. etc. complete as required. Nitrus Semi-Control Panel Make-Medinited/Unistar/Unitech

1

-

-

... More
Semi-Automatic N2O control panel. With heater, The entire manifold will be hydraulically tested at 250 Kg/Cm2 pressure, duly degreased , etc complete as required

-

-

-

... More
Distribution Copper Pipe EN: 13348,Make:-Janya/Mandev

-

-

-

... More
Medical Grade copper pipe with required copper fittings, All pipes shall be drawn half hard temp., solid drawn, seamless, phosphorous deoxidised, non-arsenic and degreased copper pipe conforming to EN BS: 13348:2008/ASTM B819 standard ,EN 1057:1996 (originally BS 2871-1971 Part 1 (Table X) and chemical composition as per BS-6017 of 1981 table 2, The supplies of copper pipe would be accompanied with manufacturers test certificate for the physical properties of copper pipes and their Chemical composition. The supply of pipes be further substantiated with inspection certificate from the third party like Lloyds Register. etc. complete as required.

-

-

-

... More
Copper Pipe 12 MM X 0.7 OD

260

-

-

... More
Copper Pipe 15 MM X 0.9 OD

530

-

-

... More
Copper Pipe 22 MM X 0.9 OD

580

-

-

... More
Copper Pipe 28 MM X 0.9 OD

490

-

-

... More
Copper Pipe 42 MM X 1.2 OD

52

-

-

... More
Isolation Ball Valve 12 MM (MAKE:-MATRIX)

18

-

-

... More
Isolation Ball Valve 15 MM (MAKE:-MATRIX)

15

-

-

... More
Isolation Ball Valve 22 MM (MAKE:-MATRIX)

12

-

-

... More
Isolation Ball Valve 28 MM (MAKE:-MATRIX)

4

-

-

... More
Isolation Ball Valve 42 MM (MAKE:-MATRIX)

2

-

-

... More
Valve With Valve Box 2 Gas (1gas+1Vac) Make-Medinited/Unistar/Unitech

3

-

-

... More
Valve With Valve Box 3 Gas (2gas+1Vac) Make-Medinited/Unistar/Unitech

5

-

-

... More
Area Alarm System Make-Medinited/Unistar/Unitech

5

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.