Rural Development Department Tender

Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.

Rural Development Department - RDD Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date30 Jan 2024
Closing Date8 Feb 2024
Tender Amount₹ 46,22,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing Cement Concrete (1:3:6) with 40mm size crusher broken granite metal of approved quality from approved quarry including hoisting lowering & levelling in position to required level in each layer not exceeding 15cm thick in foundation including frame work where necessary ramming using vibrator to proper slope and levelling curing dewatering with cost conveyance taxes royality, labour of all materials, with additional charges as decieded by the District Administration, DMF & EMF @15% on royality amount and including hire & running charges of machineries T&P required for the work including supplying & working of pumps and cess as per the specifiction and direction of Engineer-in- charge

21.26

130416

6134.36

... More
Providing Plain Cement Concrete of proportion (1:2:4) using 12 mm (1/2") size clean hard black crusher broken granite chips of approved quality and from approved quarry including hoisting lowering and laying concrete in layers not exceeding 15cm (6") thick to the required level ramming, watering & Curing etc. complete including cost & conveyance of all materials with all taxes & royalties and all labour with T&P required for the work with cess etc, with additional charges as decieded by the District Administration, DMF & EMF @15% on royality amount and including hire & running charges of machineries T&P required for the work including supplying & working of pumps and cess as per the specifiction and direction of Engineer-in- charge

5.04

38718

7682.24

... More
RCC work of grade M-20 having a minimum compressive strength in work text of 200Kg/cm2 in 15cm cubes at 28days after mixing and tests conducted using 10mm to 20mm size (20mm not to exceed 25 percent) crusher black broken granite stone chips of approved quality and from approved quarry including hoisting,lowering and laying concrete by using vibrators watering and curing for four weeks centering and shuttering and finishing the exposed surface smooth to receive painting or white or clour wasing providing grooves or beads where necessary including cost, conveyance, taxes with additional charges as decieded by the District Administration, DMF & EMF @15% on royality amount royalties of all materials and labour required for the work etc, complete with all T&P and cess in all respect but execluding cost of reinforcement MS rods or tor steel and binding wires of 18 to 20 guage and labour charges etc, complete as per specification and direction of Engineer-in-charge. Column base

14.66

103055

7029.73

... More
Column

5.49

92765

16897.22

... More
Plinth

4.29

33681

7851.26

... More
Lintel

3.15

44378

14088.56

... More
Beam

6.06

102397

16897.22

... More
Chajja

5.76

6788

1178.63

... More
Stair Case

1.53

22647

14802.46

... More
Slab

12.4

166739

13446.76

... More
1st Floor Column

3.68

70046

19034.44

... More
Lintel

2.12

33207

15664.1

... More
Beam

4.35

82799

19034.44

... More
Chajja

3.95

5267

1333.62

... More
Stair Case

1.53

25276

16520.78

... More
Slab

10.39

154748

14893.95

... More
Head Room Column

1.24

26759

21580.51

... More
Beam

0.66

14243

21580.51

... More
Chajja

7.02

10659

1518.4

... More
Slab

1.54

25582

16611.92

... More
Straightening bent up or coiled rods cutting bending,binding, cranking hooking, welding jointing (if required) the M.S.Rods or Tor steel & binding wires and binding tying the grills hoisting lowering & placing in proper position as required for RCC works with cost conveyance & taxes of M.S. Rods or Tor steel & binding wires of 18 to 20 gauge and labour with all T&P required for the work with cess etc,complete in all floors (weight of binding wire will not be considered for payment and payment will be made on weight of M.S. Rods or Tor steel only) etc. in all respects as per the direction of Engineer-in-Charge.

54.38

484755

8914.22

... More
1st Floor

27.63

247021

8940.32

... More
Head Room

4.94

44294

8966.42

... More
Fly ash brick masonary in Cement Mortar (1:6) in Foundation using Fly ash brick of 25 cm X 12 cm X 8 cm size having a crushing strength not less than 75kg per Sq.cm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering & curbelling watering and curring for 7days after immersing the bricks in water for six hours before use etc. with additional charges as decieded by the District Administration, DMF & EMF @15% on royality amount and including hire & running charges of machineries T&P required for the work including supplying & working of pumps and cess as per the specifiction and direction of Engineer-in- charge

23.58

122476

5194.08

... More
Fly ash brick masonary in Cement Mortar (1:6) in Superstrcuture using Fly ash brick of 25 cm X 12 cm X 8 cm size having a crushing strength not less than 75kg per Sq.cm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering & curbelling watering and curring for 7days after immersing the bricks in water for six hours before use etc. with additional charges as decieded by the District Administration, DMF & EMF @15% on royality amount and including hire & running charges of machineries T&P required for the work including supplying & working of pumps and cess as per the specifiction and direction of Engineer-in- charge

46.8

244876

5232.4

... More
1st Floor

30.82

170291

5525.37

... More
Head Room

9.4

54692

5818.34

... More
12mm (1/2") thick cement plaster in C.M (1:6) finsihed smooth to out side brick walls after racking out the joints including watering & curing for seven days with cost and conveyance of all materials and laobur with T&P required for the work with all taxes, royalties & cess etc, with additional charges as decieded by the District Administration, DMF & EMF @15% on royality amount and labour charges, T&P etc. required for the work complete as per specification and direction of the Engineer-in-Charge.

140.3

23288

165.99

... More
1st Floor

108.8

18717

172.04

... More
Head Room

66.43

12554

188.99

... More
16mm (5/8") thick cement plaster in C.M. (1:6) finished smooth to inside surface of 10" thick brick wall after racking out the joints including watering & curing for seven days with cost and conveyance of all materials and labour with T&P required for the work with all taxes, royalties & cess etc, with additional charges as decieded by the District Administration, DMF & EMF @15% on royality amount and labour charges, T&P etc. required for the work complete as per specification and direction of the Engineer-in-Charge.

261.3

61248

234.4

... More
1st Floor

304.4

72992

239.79

... More
Head Room

18.88

4628

245.17

... More
6mm thick cement plaster in cement mortar (1:4) to ceilling of roof lintel and chajjas after chipping and chiselling the same and clearing the surface by wire brush finished smooth watering and curing for 7 days including cost,conveyance of all materials and labour with T&P & Cess required for the work with taxes and royality etc with additional charges as decieded by the District Administration, DMF & EMF @15% on royality amount and labour charges, T&P etc. required for the work complete as per specification and direction of the Engineer-in-Charge.

83.93

14981

178.5

... More
First Floor

60.99

11144

182.73

... More
Head Room

7.24

1353

186.97

... More
Supplying,fitting & fixing Anti skid vetrified tile in floors of size 600mm x 600mm of approved make conforming to IS:13755 laid on 20 mm thick cement mortar (1:4) (1 cement:4 course sand) and filling joints with white cement of approved quality including cost of all materials with additional charges as decieded by the District Administration, DMF & EMF @15% on royality amount and labour charges, T&P etc. required for the work complete as per specification and direction of the Engineer-in-Charge.

86.69

94948

1095.26

... More
First Floor

78

86265

1105.97

... More
Fixing vetrified tiles in dadoos, skirting and risers of steps on 12mm thick CP (1:3) jointed with neat cement slurry mixed with pigments to match the shade of the tiles including cost, carriage, cost of all labour etc. complete. with additional charges as decieded by the District Administration, DMF & EMF @15% on royality amount and labour charges, T&P etc. required for the work complete as per specification and direction of the Engineer-in-Charge.

21.4

25704

1201.16

... More
First Floor

12.5

15215

1217.27

... More
Priming one coats with any approved primer over plaster surface including cost of the primer with cost conveyance and taxes of all materials and labour with T&P required for the work with cess etc, complete as per the direction of the Engineer-In-Charge.

464.13

31008

66.81

... More
First Floor

461.69

32073

69.47

... More
Head Room

92.55

6478

70

... More
Wall painting two coats with plastic Emulsion paint of approved quality & shade on new work to give an even shade with brush to interior walls surface after cleaning the surface including cost of plastic emulsion paint with cost, conveyance and taxes of all materials and labour with T&P required for the work with CESS etc complete as per direction of Engineer-in-Charge. Ground Floor

323.83

28856

89.11

... More
First Floor

352.89

32053

90.83

... More
Head Room

26.12

2417

92.56

... More
Finishing wall surface two coats with approved quality of weather coat (ISI) paint of plastered surface after celaning the surface including cost of paint, cost conveyance and taxes of all materials and labour with T&P and Cess required for the work etc, complete in all respect as per the direction of Engineer-in-Charge.

140.3

11538

82.24

... More
First Floor

108.8

9259

85.11

... More
Head Room

66.43

5844

87.98

... More
Supplying of M.S. Door, Window with grills, Grills made out of M.S. Angle frame, M.S. Flat, Sheet etc of approved section & design, electrically welded properly with all necessary locking arrengement, and 1 coat red oxide primer including cost of all materials, labour charges, carriage of materials to site etc. complete. Ground Floor

564.77

39533

70

... More
First Floor

420.58

29440

70

... More
Head Room

59.5

4165

70

... More
Supplying,fitting,fixing up window (sliding type) made up aluminum section 151-154,151-155, as windows frame sec tion no. 151-155,151-153 abd 151-167 as shuter frame with 5mm thick black glass as panel fitted with rubber beading including locking arrangement including all fitting in cluding cost of materials all taxes labour,T&P & Cess etc complete as per direction of Engineer-in-charge.

9.97

49460

4960.97

... More
First Floor

10.38

51494

4960.97

... More
Providing and Fixing ISI marked 32mm thick flush door shutters conforming to IS : 2202 (part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak three ply veneering with vertical grains or cross bands and face veneers on both faces of shutters of approved design including cost of all door fittings and fixtures etc. complete

11.63

124075

10668.61

... More
First Floor

7.75

82681

10668.61

... More
Supplying fitting of Stainless steel of 304 garde in hand railing using 50 mm dia of 2 mm thick circular pipe with balustarade of size 32 mm X 32 mm X 2 mm @ 0.90m C/C in 3 rows in stair case as per approved design and specification buffering polisging etc. including cost conveyance of all materials complete as per direction of the Engineer- in - Charge.

4.5

16675

3705.56

... More
First Floor

4.5

16675

3705.56

... More
Painting two coats with approved enamel paints of approved colour, shade over a coat of primer including sand papering, polishing the surface, cost, conveyances of all materials and cost of all labour etc, complete as per specification & direction of E.I.C.

29.33

6246

212.96

... More
First Floor

19.49

4256

218.37

... More
Head Room

2.37

530

223.95

... More
25mm thick CC 1:2:2 with 6mm size CB Chips for grading concrete over roof slab etc complete.

25.36

8948

352.84

... More
First Floor

91.38

35059

383.67

... More
Head Room

12.31

5102

414.49

... More
Providing & fixing of chequred tiles in floors of approved make conforming to IS:13755 laid on 20 mm thick cement mortar (1:4) (1 cement:4 course sand) and filling joints with white cement of approved quality including cost of all materials with additional charges as decieded by the District Administration, DMF & EMF @15% on royality amount and labour charges, T&P etc. required for the work complete as per specification and direction of the Engineer-in-Charge.

50.4

33129

657.34

... More
Earthwork in all kinds of soil in excavation of foundation trenches within 50m initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth etc all complete as per direction of the E.I.C. Initial lift upto 1.5 mtr

6.89

1571

228.21

... More
From 1.5 mtr to 3.0 mtr depth

2.3

562

244.97

... More
Supplying all materials, labour, T&P and filling in foundation and plinth with river sand well watered and rammed including conveyance of all materials to work site, payment of royalty, taxes etc all complete as per the direction of the E.I.C.

0.69

794

1155

... More
Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 40mm H.G metal including watering, curing and conveyance of all materials to site payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C.

0.46

2699

5882.3

... More
Supplying all materials, labour, T&P and providing plain cement concrete (1:1.5:3) with 12mm size H.G chips including watering, curing and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C.

0.5

4082

8149.1

... More
Supplying all materials,labour, T&P and providing Brick work with K.B.Brick having crushing strength not less than 75 Kg/CM2 with dimensional tolerence of +/- 8% in C.M including watering, curring, conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C.

3.19

17292

5426

... More
Supplying all materials, labour, T&P and providing cement plaster on brick/stone work including watering,curring and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C.

8.55

1612

188.6

... More
Supplying all materials, labour, T&P and providing cement punning on plastered surface including watering,curring and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C.

8.55

298

34.9

... More
Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for RCC work including false work and dismantling them after casting including conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C.

1.78

1201

676.9

... More
Supplying all materials, labour, T&P and providing M.S.reinforcements for RCC work including cutting, bending, binding, straightening and tying the grills and placing in position including cost of binding wire 18 to 20 gauge conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C.

0.22

1985

9024.8

... More
Supplying all materials, labour, T&P and providing Reinforced cement concrete (1:1.5:3) with 12mm size H.G chips including watering, curing and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C.

0.25

2037

8149.1

... More
Supplying all materials, labour, T&P and making M.S. Step Iron in 20mm Dia M.S Steel bars and fixing into walls of Manhole/ Septic Tanks duly embeded in C.C(1:2:4) etc all complete as per P.H specification and direction of the E.I.C.

5

1354

270.9

... More
Supplying all materials, labour, T&P and providing 50mm thick pre-cast R.C.C. baffle wall in R.C.C(1:1.5:3) including reinforcement cage using 12mm size HG chips fitted and fixed in position, finished smooth etc. complete including cutting grooves and mending good the damages etc all complete as per P.H specification and direction of the E.I.C.

0.45

447

994.1

... More
Supplying all materials, labour, T&P and providing 160mm dia P.V.C Tee inside the septic tank including cutting holes and duly embeded in P.C.C(1:1.5:3) using 12mm size HG chips fitted and fixed in position and mending good the damages etc all complete as per P.H specification and direction of the E.I.C.

2

1722

861.3

... More
Supplying all materials, labour,T&P and providing 12mm thick cement flush pointing in C:M (1:3) to Brick Masonry works including watering curring and conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C.

12.65

2045

161.7

... More
Supplying all materials, labour,T&P and filling Foundation and Plinth with excavated earth including watering, ramming etc all complete as per direction of the E.I.C.

2.2

281

128.05

... More
Supplying all materials, labour, T&P and fixing Ceramic tiles in floors, treads abd kabdubg ib 25mm thick bed of cement mortar 1:1 joined with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. all complete as per specification and direction of the E.I.C. GROUND FLOOR

8.24

10009

1214.8

... More
1ST FLOOR

5.75

7118

1238

... More
Supplying all materials, labour, T&P and fixing porcelain glazed tiles in dado skirting on 12mm thick CP 1:3 joined with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. all complete as per specification and direction of the E.I.C. GROUND FLOOR

32.59

41659

1278.3

... More
1ST FLOOR

22.24

29172

1311.7

... More
Factory made single leaf rigid FRP(alternately called GRP) sandwich composite door shutter of 32mm thick laminated with two GRP skins with wood grain finish fabricated using UV-stabilised Isopthalic Gelcoat and one layer of 450 gsm E-glass Chopped Strand Mat (CSM) impregnated with orthopthalic palyester resin. The thickness of the skins shall not be less than 1.50mm Expanded Polystyrone(EPS) structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material. Wooden reinforcements made of seasoned sal wood block of cross section not less than 28mmx32mm and also necessary sal wood reinforcements for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, the sal wood reiforcements and the skins.

7.19

22873

3181.1

... More
Factory made FRP(alternately called GRP) door frame of size 75mmx100mm fabricated using E-glass Chopped Strand Mat (CSM) U.V stabilised Inopthalic Gelcoat and impregnated with Inopthalic resin. The thickness of the GRP skins shall not be less than 2.00mm. The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The GRP frame shall be provided with wooden reinforcement on six locations for high screw holding capacity for for fixing metallic hold fast and shall be consolidated by filling with medium density foam/plaster of paris with fibre reinforcement, Six numbers of 260mm x 25mm x 5mm size 'S' shaped M.S flat hold fast shall be provided with the frame.

24.75

13654

551.7

... More
Supplying all materials, labour, T&P and cutting holes through brick/stone masonary works including making good the damages in cm (1:4) for taking GI / PVC pipes and making good the damages etc all complete as per P.H specification and direction of the E.I.C. a) 250mm to 375mm thick wall

15

3036

202.4

... More
Cutting Grooves in wall or floor

20

4110

205.5

... More
Supplying all materials, labour T&P and fitting and fixing 10 Ltrs capacity PVC low level flushing cistern with a pair of C.I. or M.S.brackets complete with fittings such as syphonic arrangement, 15mm nominal size Brass/PVC ball valve with polythene float, CP/Brass handle, unions and couplings for connection with inlet, outlet, overflow pipes, 32mm dia PVC flush bend, 15mm dia PVC connection pipes including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting inlet pipe with supply main with etc all complete as per specification and direction of the E.I.C (PARRYWARE, CERA, HINDWARE)

5

9590

1918

... More
Supplying all materials, labour, T&P and fixing water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x30mm footrest etc all complete as per specification and direction of the E.I.C. 580mmx440mm size White Orissa pan

2

7087

3543.7

... More
European water closet with ‘P’trap plain with White Plastic PVC Seat Cover

3

11143

3714.5

... More
Supplying all materials, labour, T&P and fixing wash kitchen sink/laboratory sink with C.I/M.S brackets paintedwhite including holes in walls and making good the damages etc all complete as per specification and direction of the E.I.C. 610x510x200 mm stainless steel kitchen sink

2

11943

5971.7

... More
Supplying all materials, labour T&P and fixing wash basins with C.I. or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing 32mm dia CP brass waste, etc all complete as per specification and direction of the E.I.C. a).550mmx400mm W.H.basin (PARRYWARE, CERA, HINDWARE)

4

13029

3257.4

... More
Supplying all materials, labour, T&P and fitting and fixing Brass/CP fittings of the following nominal bore with supply of all jointing materials etc. all complete as per specification and the direction of the E.I.C. (PLAZZ / Parryware / HINDWARE) A) 15mm dia CP Bib Cock (long Body)

9

8815

979.5

... More
15mm dia CP Bib Cock (Sort Body)

5

4527

905.4

... More
15mm dia CP Angle Stop Cock

11

10144

922.2

... More
15 mm dia CP Pillar Cock

4

4597

1149.4

... More
15mm dia CP concealed stop cock

6

6651

1108.6

... More
a) Fixing of 20mmx450mm long CP towel rail

5

5074

1014.8

... More
CP towel ring

4

2187

546.8

... More
fixing CP soap holder

8

2556

319.6

... More
Fixing of Glass Mirror 600mmx450mm size B.E mirror (fixed type)

4

3294

823.7

... More
25mm dia U-PVC Ball Valve[Metal Ball]

3

2383

794.4

... More
32mm dia U-PVC Ball Valve[Metal Ball]

1

1636

1636.2

... More
15mm dia CP flange

15

781

52.07

... More
15 mm C.P Extension piece 50 mm long

15

1149

76.6

... More
15mm x 225mm long size CP shower arm

4

2240

560

... More
Supplying all materials, labour, T&P and fitting and fixing U-PVC soil waste ventilating pipes of and fittings of the following outside diameter of 4kg/cm2 conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing etc all complete as per P.H specification and direction of the E.I.C. a) 110mm dia PVC SWR pipe

35

13405

383

... More
110mm dia Plain bend

4

703

175.9

... More
110mm U-PVC door bend

4

1004

251.1

... More
110mm U-PVC door Tee

4

1414

353.6

... More
110mm dia cowl

4

339

84.9

... More
125mm dia CP grating

9

777

86.4

... More
110mm dia PVC P trap

5

1905

381.1

... More
110mm dia PVC SWR offset

3

1433

477.7

... More
110mm PVC SWR S/Jn with door

2

707

353.6

... More
75mm dia PVC pipe

10

2309

230.9

... More
75mm PVC SWR plain bend

4

420

105.1

... More
75mm PVC SWR DOOR bend

2

288

144

... More
Supplying all materials, labour, T&P and providing and fixing to wall or ceilling and floor PVC pipes conforming to (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor testing etc all complete as per P.H specification and direction of the E.I.C. a) 20mm dia C-PVC pipe (Internal)

40

11144

278.6

... More
25mm dia PVC(ASTM) pipe(External)

45

4752

105.6

... More
32mm dia PVC(ASTM) pipe(External)

5

694

138.9

... More
Supplying all materials, labour, T&P and laying in trenches 4kg/cm2 U-PVC SWR soil waste ventilating pipes for sewer line of following dia in trenches (to slope or level)and jointing with supply of approved solvent cement by non-heat application method C.C (1:3:6) using 40mm size hard granite metal on bed of the trenches and all round concrete encashing with C:C (1:4:8) using 40 mm size H.G. metal, earthwork in excavation in trenches in all kinds of soil, refilling the same in a layer of 0.30mtr with watering, ramming and removing of surplus earth, testing the S.W. pipeline etc. all complete as per approved drawing, specification and direction of the E.I.C. Laying of 100 mm dia S.W Pipe line Haunch top

12

16036

1336.4

... More
Supplying all materials, labour, T&P and constructing Gully Trap chamber of the following inside size with 8 cm thick precast cover slab in CC (1:1.5:3) mix using 12 mm size H.G chips, foundation concrete (1:3:6) using 40 mm size HG metal on bed and around trap , !st class KB Brick work in CM (1:6) in F & P and inside 12 mm thick cement plaster (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap 150mmx150mm size C.I grating etc. all completed as per approved drawing, specification and direction of E.I.C. (a).Inside size 250mmx250mm

4

8427

2106.9

... More
Supplying all materials, labour, T&P and constructing Inspection Chamber of the following sizes with cement concrete (1:3:6) using 40 mm size HG metal on bed, 1st class KB Brick work in CM (1:6) moulding and shaping the channel inside and benching with C:C (1:1.5:3) using 12 mm size H.G chips, 12 mm thick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in C.C(1:1.5:3) using 12 mm size H.G chips with RCC man hole cover, earth work excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc. all complete as per approved specification and direction of E.I.C Inside size 760mm x 760mm x 460mm

3

29587

9862.4

... More
Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and 1st class KB brick work in CM (1:6) for the remaining height at top, 12mm thick Cement Plaster (1:4) inside and outside over masonry brick work, gravel packing in the rear of well steining, RCC cover slab in CC (1:1.5:3) using 12mm HG chips, fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to work site, payment of royalty, taxes etc all complete as per approved specification and direction of the E.I.C. Construction of Soak way Pit (1.00 m dia x 2.00m Deep)

1

14893

14893.9

... More
Construction of Soak way RING Pit (0.90 m dia x 2.00m Deep)

3

18557

6185.7

... More
Supplying all materials, labour, T&P and Fitting and Fixing of PVC water storage tank including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jamnuts, including hoisting upto a height of 5 mtr above G.Land placing the tank in required position including conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. 1000 Ltr capacity PVC tank (ISI mark Sintex make)

1

13612

13612.3

... More
Supplying all materials, labour, T&P and construction of masonry staging with providing 1st class K.B. Brick work in C.M.(1:6) of 0.46mtr height in staging, 12 mm cement plaster in C.M (1:6), R.C.C. Beam of 0.25mx0.30mx2.60m & roof slab of 1.40mx1.40m in C.C (1:1.5:3) using 12mm size H.G.Chips including centering, shuttering, bending and binding of rod etc watering, curring, conveyance of all materials to work site, payment of royalty, taxes etc all complete as per P.H specification and direction of the E.I.C. 1000 Ltr capacit ON ground FLOOR

1

15737

15737.7

... More
SINKING OF TW Labour for drilling a perfectly vertical bore hole at specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rigs or combination rigs as required to suit the site condition as per the direction of the Engineer-in-charge including use of own rigs with its accessories, tools and plants and consumables etc for lowering of 200 mm dia P.V.C/G.I/MS pipes for housing fitted socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/P.V.C/M.S casing pipes if required to prevent collapse of over burden is to be provided by the contractor including lowering and withdrawing after completion of the tubewell) Drilling of 125mm X 100mmdia bore-

70

47313

675.9

... More
Lowering of the following size G.I/P.V.C pipes with or without slotted pipes as per the necessary from ground level upto 30 mtrs depth and fitted and fixed up in perfectly vertical position including cutting and threading pipes and slotted pipe and supplying and fixing all jointing materials, tools and plants complete and keeping the top of the casing pipe threaded including plugging tubewell to prevent entry of foreign materials from above. a) Lowering of 125mm dia PVC pipe (Labour)

30

3660

122

... More
Cost of 125mm dia PVC pipe (Sch-80-ISI mark)

30.5

33418

1095.68

... More
Cleaning and developing the tube well using their own compressor continuously worked till clean and adequate discharge is obtained from the tubewell including supply and use of all necessary equipments and labour as per the direction of Engineer-in-charge.

1

3661

3661.3

... More
Installation of pump set Supply of ISI mark 1.00 HP single phase vertical submersible pump set with discharge of 1800-2200 ltr/hour and a head of 45-60 Mtr of reputed make like KSB/TEXMO and equivlant including all cost conveyance and taxes etc all complete as per the direction of E.I.C.

1

15849

15849.15

... More
Supplying all labour, T&P and fitting abnd fixing of 1.00 HP single phase vertical submersible pump set with commissioning and testing etc all complete as per the direction of E.I.C.

1

1475

1475

... More
Supplying all labour, T&P and fitting abnd fixing of ISI mark DOL starter of reputed make like BCH or equivalent for 1.00 HP single phase submersible pump including all cost, conveyance of all taxes etc all complete as per the direction of E.I.C.

1

2809

2809.32

... More
Supplying all labour, T&P and fitting abnd fixing of three core flat cable (1.5 mm2) of ISI mark of reputed make like BCH/Finolex or equivalent and connecting the pump and starter including all cost, conveyance and taxes etc all complete as per as per the direction of E.I.C.

50

3585

71.7

... More
Supplying all labour, T&P and fitting abnd fixing of plastic rope MS well cover, MS clamp, stainless steel short piece, bend and socket including all cost, taxes etc all complete as per as per the direction of E.I.C.

1

1660

1660

... More
Supplying all labour, T&P and fitting abnd fixing of HDPE pipe and fitting with making connection to pump set including all cost, taxes etc all complete as per as per the direction of E.I.C. A) 32mm dia HDPE pipe

37

4884

132

... More
BORE PROTECTION Supplying all materials, labour, T&P for construction of bore protection wall with providing sand filling, cement concrete (1:4:8) with HG metal & KB brick work in cement mortar (1:6) of 1.15 height, 16mm thick CP over the brick work, RCC slab of size 0.95 x 0.95 x 0.75 mtr avairage length in C 1:1.5:3, centering shutering including watering curing conveyance of all materials to work site with all cost, taxes etc all complete as per as per the direction of E.I.C.

1

6712

6712.67

... More
Wiring Recessed wiring to light point with 1.5 sq.mm FR PVC insulatedsingle core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 5Amp, 250 V piano type modular switch ISI marked and ceiling rose ISI marked mounted on MS box having front Modular base & cover of suitable size , MS box with 1 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire Finolex/ L&T / Anchor / Havels /HPL/ V Guard ) -do- Group A

23

10855

471.98

... More
-do- Group B

21

14995

714.06

... More
-do- Group C

10

10187

1018.74

... More
Recessed wiring to Fan Point in... -do- Group B

10

7140

714.06

... More
Recessed wiring to Call Bell Point in... -do- Group C

3

3056

1018.74

... More
Recessed wiring to Exhaust Fan Point in….. -do- Group C

7

7131

1018.74

... More
S/F of fan hook 'S' type made of 16 mm MS rod for fixing in the Existing RCC Roof.

10

2624

262.43

... More
S/F of Angle holder replacing Ceilling Rose

28

495

17.7

... More
Swich Boards S/F of 5A. Modular Switch & 5A. Modular Socket outlet of ISI marked on existing board

28

6375

227.69

... More
S/F of extension board of 6 modular Metal box with modular base & cover in recess including providing and fixing of 2 nos of 3pin 5/6amp modular socket out let & 2 nos of 5/6 amp piano type modular switch, connection, painting etc as required.

13

10177

782.87

... More
S/F of Power point with 4 modular metal box with modular base & cover in recess including providing and fixing of 5 pin 15/16 amp. piano type Modular switch & Socket, connection, painting etc as required

5

3257

651.54

... More
S/F of Power point with 4 modular & 2 modular metal box with modular base & cover in recess including providing and fixing of 5 pin 15/16 amp. piano type Modular switch & Socket & Mini DP MCB, connection, painting etc as required for AC

3

3921

1307.1

... More
S/F of computer board consisting of 3 nos of 5amp modular plug and modular switch & 1 no of Mini MCB complete with wiring on 12 modular M.S. box with modular cover.

4

5448

1362.15

... More
S/F of 1 no of 5 pin 15/16 amp. Socket , 1 no of switch & 1 no of 15/16A top with modular mini MCB, in 6 modular box with cover with connection, painting etc as required for Inverter connection

2

2014

1007.2

... More
S/F of 18 SWG Modular metal box of following sizes (Nominal size) in recess with suitable size of Modular base & cover in front including cutting the wall and making good the same in case of recessed conduit as required. 2 Modular box with base & cover

20

4430

221.54

... More
4 Modular box with base & cover

3

806

268.83

... More
6 Modular box with base & cover

4

1309

327.49

... More
8 Modular box with base & cover

2

738

369.43

... More
12 Modular box with base & cover

8

3856

482.08

... More
Sub-Main Wiring for circuit / sub-main wiring along with earth wire with following sizes of PVC insulated single core multistrand copper conductor with ISI marked conforming to IS-694/1990 in 20mm dia non metalic heavy duty flexible conduit 1.6mm in recessed PVC conduit as required (Make of wire - Finolex/L&T/Anchor/Havels/V-guard) 2x1.5+1x1.0 (1.8)

88

11698

132.94

... More
2x2.5+1x1.5 (1.8.2)

247

36533

147.91

... More
2x4+1x1.5 (1.8.3)

120

19834

165.29

... More
Inverter wiring (1x1.5smm) Copper wire (1.19.1)

111

5464

49.23

... More
Circuit Breakers S/F of 'B/C/D' series SP MCB of 5 - 32A amp rating (As per direction of engineer in charge) 240Volt for lighting and other loads in the existing MCB Distribution board ISI marked complete with connection, testing and commissioning etc. as required single pole (SP) (2.6.1)

18

2404

133.6

... More
Supply, Installation testing & commissioning of Main Switches (IS13940 part 3/1993) of following coopacity on existing surface/wall mounting & complete with H.R.C fuse links, inter connections earthing etc as required as per direction of Engineer Incharge (Make-Seimens/HPL/Anchor/L&T /Havels/C&S/R. K.) S/F of MCB 12 way Double door (2.3.7)

2

3822

1911.25

... More
Main switches Supply, Installation testing & commissioning of Main Switches (IS13940 part 3/1993) of following coopacity on existing surface/wall mounting & complete with H.R.C fuse links, inter connections earthing etc as required as per direction of Engineer Incharge (Make-Seimens/HPL/Anchor/L&T /Havels/C&S/R. K.) S/F of 63A ICDP main switch with MS box of 250mmx300mmx60mm deep ( (2.15A)+(1.24.16 )

2

4714

2357.16

... More
Earthing Supply & laying 8 SWG Cu wire in recess for loop earthing as required (3.18)

15

1453

96.87

... More
S/F of Cu .Earth Plate Earthing 600 mm x600mmx3.15mm with Salt & Charcoal for Earth electrode (3:5)+(3.6)

2

11321

5660.74

... More
Fittings Supply, Installation, Testing & Commissioning of exhaust fan upto 450 mm sweep in the exising opening, including making the hole to suit the size of the above fan making good the damaged complete, connection, etc as required. (1.43)

7

22712

3244.68

... More
S/F of Call bell/Buzzer(Ding dong type) ISI marked suitable for DC/AC single phase 230 volts complete as required. (1.30)

3

372

124.27

... More
S/F of 18-25Watt L.E.D Tube light fitting with all accessories and connections (Make:HPL-Neptune Havells-Elite LED Pride Plus/PAC/Crompton-RetroPLL

19

13174

693.41

... More
Supply of 1200mm BLDC A.C. Ceiling fan with all accessories and connections with out fan regulator (Make:Usha-Energia-32/Polycab-Affeciente Neo/Crompton-Energion /Havels-Efficiencia DX/Orient-Ecotech Supreme/Anchor-Eco Breeze urban )

10

45772

4577.21

... More
S/F step type modular fan regulator

10

2848

284.81

... More
Supply & fixing of superior type Led bulk head fitting general domestic use ISI marked square / oval type including necessary connections. ( M-5 )

3

1818

606.05

... More
Supply & Fixing of 45-48 Watt single L.E.D street light fitting with LED & Electrinic driver including all accessories and connections (Make:Crompton/Phillips/HPL/Polycab/Havells)

3

17187

5729.04



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.