Rural Development Department Tender
... More
Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.
Costs
EMD
₹ 2,81,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_CERWI_74422_45Bid Award Id
ViewTender No
Tender Online RCK-04/19Tender Authority
Rural Development Department ViewPurchaser Address
-Website
http://http://rdodisha.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Removing all types of Hume pipes and stacking within a lead of 1000 m including Earthwork and Dismantling of Masonry Works as per Technical Specification Clause 202 of MoRD excluding cost of excavation of earth,dismantling of stone masonry in headwall & protective work etc complete as per direction of Engineer in charge.
30
7164
238.8
... More
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement as per MORD technical Specification Clause 301 and direction of the Engineer in Charge
232.09
6600
28.44
... More
Construction of embankment with approved material obtained from borrow pits with all lifts and leads, transporting to site by mechanical means, spreading, grading to required slope and compacting to meet requirement as per Technical Specification Clause 301 of MoRD for Rural roads and as per direction of Engineer-in-Charge.
9215.76
1479221
160.51
... More
Providing Construction of granular sub-base Gr-III by providing well graded material, spereading in uniform layers with tractor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per MORD Technical Specification clause 401 and as per direction of Engineer in Charge.
1941.25
2266681
1167.64
... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density as per Technical Specification Clause 405 of MoRD by manual means and as per direction of the Engineer-in-Charge.
-
-
-
... More
Grading No.-II(With Crushable Screening)
771.22
1643384
2130.89
... More
Grading No.-III (With Crushable Screening)
771.22
1604045
2079.88
... More
Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502 of MoRD for low porosity surface & as per direction of the Engineer-in-Charge.
10282.83
302623
29.43
... More
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503 of MoRD & as per direction of the Engineer-in-Charge.
10282.83
105296
10.24
... More
Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates using S-65 penetration grade bitumen to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of Type C as per Technical Specification Clause 508 of MoRD by manual means i.e., without paver finisher & as per direction of the Engineer-in-Charge. (Cold Mix Bitumen)
10282.83
1346742
130.97
... More
Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type C as per Technical Specification Clause 510 as per the direction of the Engineer-in-charge. (Cold Mix Bitumen)
10282.83
454295
44.18
... More
Fine dressing and turfing including transportation by mechanical means with all leads and lifts and placing of turfs in position and ramming with thapies including watering and cost of labour and all materials etc. complete as per the direction of the Engineer-in-Charge.
10712.78
191008
17.83
... More
Rigid Pavement
-
-
-
... More
Providing Construction of granular sub-base Gr-III by providing well graded material, spereading in uniform layers with tractor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per MORD Technical Specification clause 401 and as per direction of Engineer in Charge.
253.79
296335
1167.64
... More
Construction of Panelled cement concrete pavement, thickness as per design, over a prepared sub-base, with 43 grade cement or any other type as per Clause 1501.2.2, M30 (grade) coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25mm mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the form work as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars near approaches to bridges and culverts (expansion joints), admixtures as approved, curing of concrete slabs for 14 days, curing compound and water finishing to lines and grade as per drawing and Technical Specification Clause 1501. and as per direction of the Engineer-in-charge.
188.9
912713
4831.73
... More
Cross Drainage Works
-
-
-
... More
Earthwork in excavation for foundation of structures upto 3 m depth as per drawing and technical specification Clause 305.1 includding setting out, construction of shoring and bracing, removal of stumps and other deleterious materials, disposal upto 50m, dressing of sides and bottom and backfilling with approved excavated material and as per direction of the Engineer-in-Charge.
101.16
27522
272.07
... More
Providing and laying of Type-B (first class) bedding for laying of Hume Pipe on well compacted moorum or approved granular material as per MORD Technical Specification clause 1105(ii) and as per direction of the Engineer-in-Charge.
6.68
6384
955.7
... More
Plain/reinforced cement concrete in open foundation complete as per drawings & Technical Specification Clauses 802, 803, 1202 & 1203of MORD and as per direction of Engineer-in-Charge
9
35054
3894.89
... More
Plain cement concrete M-15 nominal mix (1:2½:5) in Sub-structure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 of MORD specification for Rural roads and as per the direction of the Engineer-in-Charge.
74.71
307249
4112.56
... More
Providing and laying reinforced cement concrete pipe NP3 for culverts including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106 of MoRD & as per direction of the Engineer-in-Charge.
-
-
-
... More
1000 mm dia Hume Pipe single row
30
179528
5984.28
... More
Protection Works
-
-
-
... More
Earthwork in excavation for foundation of structures upto 3 m depth as per drawing and technical specification Clause 305.1 includding setting out, construction of shoring and bracing, removal of stumps and other deleterious materials, disposal upto 50m, dressing of sides and bottom and backfilling with approved excavated material and as per direction of the Engineer-in-Charge.
331.56
90207
272.07
... More
P.C.C. grade M-15 (1:2.5:5 Nominal mix) in open Foundations complete as per drawings and technical specification Clauses 802, 803, 1202 and 1203 of MORD specification for Rural roads and as per the direction of the Engineer-in-Charge.
62.84
244754
3894.89
... More
P.C.C. grade M-15 (1:2.5:5 Nominal mix) in Sub-structure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 of MORD specification for Rural roads and as per the direction of the Engineer-in-Charge.
326.68
1343491
4112.56
... More
Providing weepholes in brick masonry/ stone masonry, plain/ reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and MORD technical specification Clauses 614, 709, 1204 and as per direction of the Engineer in charge
192.67
33202
172.33
... More
Road Furnitures
-
-
-
... More
Providing and fixing typical PMGSY informatory sign board with Logo as per MORD specification and drawing.Three MS Plates of 1.6mm thick, top and middle plate duly welded with MS flat iron 25mm x 5mm size on back edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm . The angle iron frame of lower most plate and flat iron frame of middle of middle plate will be welded to 2 Nos. 75mm x 75mm x of 12 SWG sheet tubes posts duly embeded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm ,600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S will be stove enamelled on both sides.Lettering and printing arrows, boarder etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour.All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 and as per Direction of Engineer-in-Charge.
2
19491
9745.97
... More
Reinforced cement concrete M15 grade Guard stone/ Boundary pillars of standard design as per IRC:25 fixed position including finishing and lettering but excluding painting as per drawing and Technical specification Clause 1704 of MORD and as per Direction of Engineer-in-Charge.
31
23706
764.71
... More
Reinforced cement concrete M15 grade Kilometer stone of standard design as per IRC:8 fixing in position including painting & printing etc. as per the drawing &technical specification clause 1703 of MoRD and as per direction of Engineer-in-Charge.
-
-
-
... More
b) Ordinary Kilometer Stone (precast)
3
5197
1732.56
... More
c) 200 Meter Stone (precast)
12
5894
491.18
... More
Providing and erecting direction and place identification of semi-reflective sign boards as per IRC:67 made of 2mm thick M.S.sheet duly stove enamelled paint in white colour in front and grey colour on back with red reflective boarder of 70 mm width and required message, letters,figures with reflective engineering grade tape as per MORD specification of required shade and colour. Supported and welded on 47mm x 47mm of 12 SWG Square tube of 3050mm height duly strengthened by 25mm x 5 mm M/s flats iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450mm X 450mm x 600mm,600mm below ground level as per approved drawing and technical specification clause 1701. of MoRD as per direction of the Engineer-in-Charge.
-
-
-
... More
600 mm Equilateral Triangle
12
16914
1409.56
... More
Providing and fixing of typical PMGSY Citizens information board as per MORD specifications and drawing. Three MS Plates of 50 X 5 mm thick, back plate duly welded with 75mm dia steel tubes back on edges as per drawings. The lower & upper plate will be welded with MS flat iron frame of 50mm x 5mm. The steel tubes duly embeded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm below ground level. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 and as per direction of Engineer in Charge.
3
47657
15885.99
... More
Providing and erecting direction and place identification of semi reflective sign boards as per IRC-67 made of 2 mm thick M.S. Sheet duly stove enameled paint white colour in front and grey colour on back with reflective border of 70 mm width and required message, letters, figures with reflective tape of engineering grade as per MORD specifications of required shade and colour. Supported and welded on two nos. 47 mm x 47 mm of 12 SWG square tube of 3050 mm height duly strengthened by 25 mm x 5 mm MS flat iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701 (upto 0.90 square meter size) and as per direction of the Engineer-in-charge.
8
13857
1732.16
... More
Providing and fixing of typical PMGSY maintenance information board as per MORD specifications and drawing. Three MS Plates of 50 X 5 mm thick, back plate duly welded with 75mm dia steel tubes back on edges as per drawings. The lower & upper plate will be welded with MS flat iron frame of 50mm x 5mm. The steel tubes duly embeded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm below ground level. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 and as per direction of Engineer in Charge.
1
15885
15885.99
... More
TOTAL PART-I
1
13062157
1
... More
Routine Maintenance after completion of Construction works
-
-
-
... More
For 1st Year
3.1
133595
43095.16
... More
For 2nd Year
3.1
175883
56736.45
... More
For 3rd Year
3.1
199633
64398.06
... More
For 4th Year
3.1
231251
74597.1
... More
For 5th Year
3.1
254884
82220.65
... More
TOTAL PART-II
1
995247
1
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements