Rural Development Department Tender

Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.

Rural Development Department - RDD Tender

Works
Building Construction
Eprocure
Opening Date4 Jan 2025
Closing Date20 Jan 2025
Tender Amount₹ 44,63,83,856 
Notes
Download

Costs

Summary

Construction Of Newly Proposed 100 Bedded Sdh Medical Building

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
INTERNAL ROAD

980

-

-

625

-

-

... More
COMPOUND WALL

250

-

-

... More
Filling in foundation trenches and plinth, with excavated earth including laying the earth in layers not exceeding 23.5 cm thick ramming & watering with all leads & lifts including cost of all labour,T&P completed as directed by the Engineer-in-charge.

-

-

-

... More
BUILDING

5397.47

-

-

... More
SECURITY ROOM AND GATE COMPLEX

115.74

-

-

... More
INTERNAL ROAD

857.5

-

-

246.2

-

-

... More
COMPOUND WALL

166.67

-

-

... More
Supplying and filling in foundation and plinth with good quality river sand including watering, ramming with cost, conveyances, royalties of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer-in-charge.

-

-

-

... More
BUILDING PROPER

1378.46

-

-

... More
SECURITY ROOM AND GATE COMPLEX

16.32

-

-

... More
INTERNAL ROAD

367.5

-

-

93.75

-

-

... More
COMPOUND WALL

26.8

-

-

... More
Providing & applying of pre constructional anti-termite treatment by drilling 12mm dia holes at distance of 30cm @ junction of wall & floor about 300mm apart deep enough to reach the soil below & chemical emulsion (IMIDACHLOPRIED 30.5SC mixed with 47.5ltr water) pumped these holes to soak the soil @ 1 ltr solution of each hole as per manufactures specification & the holes should be pluged the filling materials including cost of all materials, labour,conveyance, T&P , all taxes and hire charges of machinaries as per direction of Engineer-in-charge.(make-premise-BAYER,Paxton-FMC,ozie-KALYANI)

-

-

-

... More
BUILDING

8187.39

-

-

... More
SECURITY ROOM AND GATE COMPLEX

26.98

-

-

... More
Providing and laying plain cement concrete of proportion (1:3:6) in foundation and floors using 4 cm. size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality and from approved quarry including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm. thick in each layer including cost, conveyance, royalties of all materials and cost of all labours,labour cess, T&P etc complete as per the direction of the Engineer-in-charge.

-

-

-

... More
BUILDING PROPER

538.27

-

-

... More
SECURITY ROOM AND GATE COMPLEX

14.6

-

-

93.75

-

-

... More
COMPOUND WALL

17.87

-

-

... More
Plain cement concrete (1:2:4) using 12mm size black hard crusher broken granite chips of approved quality from approved quarry including hoisting, lowering and laying concrete in layers, watering, curing etc. complete including cost, conveyance, royalties of all materials with labour,labour cess and T&P etc. required for the work complete as per the direction of the Engineer-in-charge.

-

-

-

... More
BUILDING

421.89

-

-

... More
SECURITY ROOM AND GATE COMPLEX

2.76

-

-

... More
Fly Ash brick masonry in cement mortar (1:6) in foundation & plinth using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge.

-

-

-

... More
BUILDING

113.95

-

-

... More
SECURITY ROOM AND GATE COMPLEX

6.48

-

-

... More
COMPOUND WALL

13.5

-

-

... More
Fly Ash brick masonry in cement mortar (1:6) in super structure using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge.

-

-

-

... More
BUILDING

-

-

-

... More
GROUND FLOOR

280.98

-

-

... More
FIRST FLOOR

258.78

-

-

... More
SECOND FLOOR

223.53

-

-

... More
THIRD FLOOR

218.24

-

-

... More
FOURTH FLOOR

217.8

-

-

... More
TERRACE FLOOR

146.7

-

-

... More
COMPUND WALL

82.8

-

-

... More
SECURITY ROOM AND GATE COMPLEX

64.12

-

-

... More
Fly Ash brick masonry in cement mortar (1:4) in super structure using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge.

-

-

-

... More
BUILDING PROPER

-

-

-

... More
GROUND FLOOR

295.52

-

-

... More
FIRST FLOOR

276.57

-

-

... More
SECOND FLOOR

190.7

-

-

... More
THIRD FLOOR

200.7

-

-

... More
FOURTH FLOOR

173.52

-

-

... More
Providing and laying in position ready mixed M-25 grade concrete having compressive strength at 28 days test not less than 250 kg/ sq.cm for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying , including the cost of centering, shuttering finishing and excluding reinforcement including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, and hoisting, lowering, laying and compacting concrete, watering and curing and finishing the exposed surfaces smooth with cost, conveyance, royalties, taxes of all materials with all labour,Labour cess and T&P required for the work improve workability without impairing strength and durability as per direction of the Engineer - in - charge.

-

-

-

... More
BUILDING PROPER

-

-

-

... More
FOOTING

2693.25

-

-

... More
COLUMN UP TO PLINTH

94.99

-

-

... More
PLINTH BEAM

185.11

-

-

... More
SECURITY ROOM AND GATE COMPLEX

-

-

-

... More
FOOTING

23.82

-

-

... More
COLUMN UP TO PLINTH

4

-

-

... More
PLINTH BEAM

4.98

-

-

... More
COMPOUND WALL

-

-

-

... More
FOOTING

33.6

-

-

... More
COLUMN UP TO PLINTH

5.38

-

-

... More
PLINTH BEAM

13.5

-

-

... More
E)COPING AT TOP OF COMPOUND WALL

6

-

-

... More
R.C.C COLUMN

-

-

-

... More
GROUND FLOOR

143.47

-

-

... More
FIRST FLOOR

137.79

-

-

... More
SECOND FLOOR

117.44

-

-

... More
THIRD FLOOR

117.44

-

-

... More
FOURTH FLOR

108.16

-

-

... More
TERRACE FLOOR

55.51

-

-

... More
SECURITY ROOM AND GATE COMPLEX

18.3

-

-

... More
COMPOUND WALL

11.95

-

-

... More
SHELVES

-

-

-

... More
GROUND FLOOR

44.55

-

-

... More
FIRST FLOOR

21.92

-

-

... More
SECOND FLOOR

38.63

-

-

... More
THIRD FLOOR

49.65

-

-

... More
FOURTH FLOR

28.74

-

-

... More
R.C.C LINTEL

-

-

-

... More
GROUND FLOOR

33.26

-

-

... More
FIRST FLOOR

33.9

-

-

... More
SECOND FLOOR

30.1

-

-

... More
THIRD FLOOR

30

-

-

... More
FOURTH FLOR

20.97

-

-

... More
TERRACE FLOOR

0.27

-

-

... More
SECURITY ROOM AND GATE COMPLEX

0.54

-

-

... More
R.C.C CHAJJA

-

-

-

... More
GROUND FLOOR

79.44

-

-

... More
FIRST FLOOR

59.87

-

-

... More
SECOND FLOOR

63.84

-

-

... More
THIRD FLOOR

64.76

-

-

... More
FOURTH FLOR

54.64

-

-

... More
TERRACE FLOOR

4.71

-

-

... More
R.C.C ROOF BEAM

-

-

-

... More
GROUND FLOOR

223.02

-

-

... More
FIRST FLOOR

134

-

-

... More
SECOND FLOOR

152

-

-

... More
THIRD FLOOR

151

-

-

... More
FOURTH FLOOR

73.7

-

-

... More
TERRACE FLOOR

73.81

-

-

... More
SECURITY ROOM AND GATE COMPLEX

10.42

-

-

... More
R.C.C SLAB

-

-

-

... More
GROUND FLOOR

409.52

-

-

... More
FIRST FLOOR

315.84

-

-

... More
SECOND FLOOR

312.02

-

-

... More
THIRD FLOOR

309.99

-

-

... More
FOURTH FLOR

274.6

-

-

... More
TERRACE FLOOR

26.15

-

-

... More
SECURITY ROOM AND GATE COMPLEX

10.72

-

-

... More
R.C.C STAIRCASE

-

-

-

... More
GROUND FLOOR

24.66

-

-

... More
FIRST FLOOR

24.66

-

-

... More
SECOND FLOOR

24.66

-

-

... More
THIRD FLOOR

24.66

-

-

... More
FOURTH FLOR

24.66

-

-

... More
R.C.C. work of M-20 in following works using 12 mm. to 20 mm. (½” to ¾”) size (20 mm. not to exceed 25%) hard black crusher broken granite stone chips of approved quality from approved quarry including hoisting, lowering, laying and compacting concrete, watering curing, centering, shuttering and finishing the exposed surfaces smooth with cost, conveyance, royalties, taxes of all materials with all labour,labour cess and T & P required for the work etc. complete in all respect but excluding the cost and conveyance of M.S. rods or Tor steel and binding wire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding and tying the grills and placing in proper position and as per the direction of the Engineer-in-charge.

-

-

-

-

-

-

... More
BASE SLAB

78.8

-

-

112.5

-

-

... More
COVER SLAB

65.6

-

-

... More
Supplying Cutting, straightening coiled or bent up M.S. Rod or tor steel of primary steel producers such as SAIL / TATA / RINL / JINDAL STEEL / SHYAM STEEL/ SEL Tiger (grade Fe-500D) etc. including bending, binding, welding and jointing if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors with labour cess etc. (payment will be made on standard weight of B.I.S. for M.S. Rods or tor steel only) etc. complete as per specification & direction of Engineer-in-charge.

-

-

-

... More
BUILDING PROPER

-

-

-

... More
GROUND FLOOR

3014.25

-

-

... More
FIRST FLOOR

839.19

-

-

... More
SECOND FLOOR

828.06

-

-

... More
THIRD FLOOR

825.02

-

-

... More
FOURTH FLOR

627.64

-

-

... More
TERRACE FLOOR

252.59

-

-

... More
SECURITY ROOM AND GATE COMPLEX

89.46

-

-

... More
COMPOUND WALL

69.22

-

-

136.16

-

-

... More
Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.

-

-

-

... More
GROUND FLOOR

4430.39

-

-

... More
1ST FLOOR

3520.99

-

-

... More
2ND FLOOR

3615.43

-

-

... More
3RD FLOOR

3074.66

-

-

... More
4TH FLOOR

2856.63

-

-

... More
HEAD ROOM

1499.92

-

-

... More
SECURITY ROOM & MAIN GATE

372.72

-

-

... More
COMPOUND WALL

400

-

-

... More
Providing 16 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.

-

-

-

... More
GROUND FLOOR

4430.39

-

-

... More
1ST FLOOR

3520.99

-

-

... More
2ND FLOOR

3615.43

-

-

... More
3RD FLOOR

3074.66

-

-

... More
4TH FLOOR

2856.63

-

-

... More
HEAD ROOM

1499.92

-

-

... More
SECURITY ROOM & MAIN GATE

146.9

-

-

... More
COMPOUND WALL

418.76

-

-

... More
Providing 6 mm thick cement plaster with cement mortar of mix (1:4) with screened and washed sharp sand for mortar and finished smooth to R.C.C. work after closed deep chipping & slurry treatment including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.

-

-

-

... More
GROUND FLOOR

1492.01

-

-

... More
1ST FLOOR

1246.27

-

-

... More
2ND FLOOR

1426.47

-

-

... More
3RD FLOOR

1514.12

-

-

... More
4TH FLOOR

882.13

-

-

... More
HEAD ROOM

498.56

-

-

... More
SECURITY ROOM & MAIN GATE

114.58

-

-

... More
COMPOUND WALL

150

-

-

... More
Providing full body matt finish vitrified tile flooring using vitrified tiles having thickness of min 10mm conforming to IS 13755 of 1200x600 (shade to be decided as per Ama Hospital scheme) (homogeneous) of premium quality (JOHNSON / SOMANY/ KAJARIA/ RAK) in floors, treads on steps and landings on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and fixing with neat white cement slurry,grouting the joints with neat white cement slurry mixed with required quantities of pigments of approved make to match the shades of the vitrified tile if required , watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour,Labour cess , sundries, T&P required for the work, complete in all respect as per specification and direction of Engineer-in-charge.

-

-

-

... More
GROUND FLOOR

1765.77

-

-

... More
1ST FLOOR

1504.81

-

-

... More
2ND FLOOR

1555.55

-

-

... More
3RD FLOOR

1266.31

-

-

... More
4TH FLOOR

1023.31

-

-

... More
Providing, fitting, fixing vitrified tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 600mm x 600mm Plain (Ivory) of approved make (JOHNSON / SOMANY/ KAJARIA/ RAK) as directed by Engineer-in-charge in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties of all materials all labour,labour cess complete in all respects.

-

-

-

... More
GROUND FLOOR

1467.35

-

-

... More
1ST FLOOR

1471.26

-

-

... More
2ND FLOOR

1195.67

-

-

... More
3RD FLOOR

1645.66

-

-

... More
4TH FLOOR

900.59

-

-

... More
Supplying, fitting and fixing full body vetrified tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 600mm x 600mm Plain (Ivory) of approved make (JOHNSON / SOMANY/ KAJARIA/ RAK) in floors on 20mm thick bed of C.M. (1:4)(1cement:4course sand) and filling the joint with white cement mixed with pigment to match the shades of the tileincluding cost of all materials, labour, labour cess, T&P etc. required for the work complete in all respect as directed by the Engineer in charge.

-

-

-

... More
SECURITY ROOM AND GATE COMPLEX

26.98

-

-

... More
Fixing of Ceramic wall tiles of premium grade having thickness 6.50mm to 7.00mm confirming to IS 13753 of size 60cm x 30cm special plain / printed series in dados skirting & riser of steps on 12mm thick cement plaster 1:3 joined with neat cement slurry mixed with pigments to match the shade of the tiles, including rubbing & polishing etc. complete including cost, conveyance, royalties of all materials, labour with T&P complete in all respects as per direction of Engineer-in-Charge.(make-Somany,Johnson,RAK,Kajaria)

-

-

-

... More
SECURITY ROOM & MAIN GATE

27.02

-

-

... More
Fixing granite tiles of approved dimension area above 0.4 sqm (20mm thick) in floor, treads of steps and landing on 20mm thick bed of cement mortar (1:4) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties and taxes of all materials complete in all respects as per direction of Engineer-in-Charge.

-

-

-

... More
BUILDING

-

-

-

... More
GROUND FLOOR

198.59

-

-

... More
1ST FLOOR

174.04

-

-

... More
2ND FLOOR

192.15

-

-

... More
3RD FLOOR

204.05

-

-

... More
4TH FLOOR

179.89

-

-

... More
Fixing granite tiles of approved dimension area above 0.1 up to 0.4 sqm (10mm thick) in Dados, treads of steps and landing on 12mm thick cement mortar (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties and taxes of all materials complete in all respects as per direction of Engineer-in-Charge.

-

-

-

... More
BUILDING

-

-

-

... More
GROUND FLOOR

91.18

-

-

... More
1ST FLOOR

91.18

-

-

... More
2ND FLOOR

91.18

-

-

... More
3RD FLOOR

91.18

-

-

... More
4TH FLOOR

91.18

-

-

... More
Supplying, fitting and fixing vetrified Industrial tiles in floors of premium grade having thickness 8mm to 10mm of Size 300mm x 300mm confirming to IS 4457 with colour / printed series of approved make (JOHNSON /RAK / SOMANY/ KAJARIA or equivalent ) on 20mm thick bed of C.M. (1:4) including cost of all materials, labour, T&P etc. required for the work in all respect as directed by the Engineer in charge.

-

-

-

... More
GROUND FLOOR

359.81

-

-

... More
1ST FLOOR

171.69

-

-

... More
2ND FLOOR

171.69

-

-

... More
3RD FLOOR

171.69

-

-

... More
4TH FLOOR

171.69

-

-

... More
Supply and istallation of 2mm elctorstatic dissipetive flooring of robust E17as per selected shade: Dissipative homogeneous PVC floor coverings in rolls or tiles with permanent antistatic propoties less than 2KV. The value of the electrical resistantance is in the range of 106 to 1080 of standards EN 1081 static electirical propensity less than 2 and as per standard EN1815. Abrosion value according to EN 660.2less than or eqal to 4.00mm 3, group M, fire class Bfls1,load class 34/43.after 28days the TVOC 10µg/m³ accoriding ti ISO 16000-6.REACH copliant,ISO 717-2weighted improvement of impact sound inslation is 4db.Price includes Supply, welding rod,30mm coving then installation and transportaion.

-

-

-

... More
GROUND FLOOR

129.81

-

-

... More
1ST FLOOR

31.89

-

-

... More
2ND FLOOR

220.01

-

-

... More
3RD FLOOR

259.89

-

-

... More
4TH FLOOR

331.91

-

-

... More
Providing and fixing of 12mm thick 100% Acrylic UV Solid Surface of approved make IW - 118 (I - White ) shade in approve design,with ISO 14001 -2015 and ISO 9001 - 2015 certified with properties like esterior uv Non - Porous,Themofomable,Unnoticeable joints after appliications,bacteria & antifungal resistance ,heavy duty scratch & stain resistant,impact resistant,insulative & non conductive,Green Biliding IGBC certified,Fire rating as per standard DIN1402-1 Surface spread of flame and having minimum specific Gravity 1.65g/cm3 properties. With additional propoerties like Tensile strength -54.5 N/mm2 Elongation at break ,2% (speed 5mm /min),flexural Strength -60 N/mm2 (Speed 2mm ?min.),Density -1.74 /cc ,Water Absorption -0.02% (At R.T.For 24 hour) Abrasion Resistance Test -19.4,Barcol,Hardness -60 -62,Limiting thermal,Expansion,mm/mm/c-10x10/c-10x10c(degree celcius),Boiling water resistance (At Boiling water for 20 mimutes) -No change in surface colour.

-

-

-

... More
Application of Acrylic UV solid surface sheets to be cut,pasted and finished in approved shade,as per approved design by the Engineer in charge.This solid surface should be fixed over Plyboard supporting structure with all mechanical fixtures as per specification ,drawings and giudlines from the technical person from supplier company .The quoted rates shall inclusive off material cost with fabrication & installation at site.Cost of silicon & approved adhesives ,chamfering of edges flushing of joints and final finshing as per directions of Engineer-in-charge .Complete including cost of all material,Labourrequird for the work,(Make duralaxIndia /merino Hanex.

-

-

-

... More
GROUND FLOOR

133.74

-

-

... More
FIRST FLOOR

48.66

-

-

... More
SECOND FLOOR

157.96

-

-

... More
THIRD FLOOR

132.48

-

-

... More
FORTH FLOOR

874.28

-

-

... More
Providing and fixing factory made 100% solid WPC (Wood Polymer Composite) door frame 125mm x 65mm single rebated made from wood polymer composite (Single extruded process) material comparising of virgin PVC polymer of K value 57-60(Suspension grade) calcium carbonate and natural fibers (Wood Powder / Rice Husk / Wheat husk) and non-toxic additives fabricated with metre joint after applying PVC sulvant cement and screwd with full body treaded start headed screw having minimum frame density of 780kg per/Cbm and an ISO 9001-2015 certified company having good screw holding capacity (Screw withdrawal strength of (minimum 990N)), minimum compressive strength of 58N/mm2, modulus of elasticity 900N/mm2 and resistance to spread of flame of Class A catogary with property of being termite/ borer proof, Water/moisture proof and fire retardant and fixed in position with SS dash fasteners/ Hold fast of required dia and length, all as per specifications drawings as directed by the Engineer-in-Charge. Material test certificate and authentication should be compulsaryly provided by the manufacturing company.

-

-

-

... More
GROUND FLOOR

375.75

-

-

... More
FIRST FLOOR

325.95

-

-

... More
SECOND FLOOR

277.35

-

-

... More
THIRD FLOOR

338.55

-

-

... More
FORTH FLOOR

273.6

-

-

... More
SECURITY ROOM & MAIN GATE

20.1

-

-

... More
Supplying, fitting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality including cost of all door fittings and fixtures etc. complete in all respect as per the direction of the Engineer-in-Charge.

-

-

-

... More
GROUND FLOOR

176.04

-

-

... More
FIRST FLOOR

140.7

-

-

... More
SECOND FLOOR

141.12

-

-

... More
THIRD FLOOR

130.83

-

-

... More
FORTH FLOOR

107.07

-

-

... More
SECURITY ROOM & MAIN GATE

6.94

-

-

... More
Supplying and installing UPVC- 3 tracks sliding windows and 2 sashes (shutters) with ss mesh sash dimension of 58 mm x 32 mm and sash dimension of 61mm x 37mm for windows with corners fusion welded, fully reinforced with Galvanized steel of 1.2 mm to 2 mm. The sash will be fitted with 5mm reflective toughened glass of make - Saint gobain/AIS/Gardian/modi . The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets,bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside / Outside of Dowcorning / GE or equivalent including cost of all materials, all labour, sundries, T&P etc. complete in all respect as per approved drawing & direction of Engineer-in-Charge. (Prominence / FENESTA/NCL VEKA LTD./ Koemmerling/ DURAPLAST).

-

-

-

... More
GROUND FLOOR

273

-

-

... More
FIRST FLOOR

203.59

-

-

... More
SECOND FLOOR

213.93

-

-

... More
THIRD FLOOR

238.54

-

-

... More
FORTH FLOOR

172.22

-

-

... More
HEAD ROOM

6.75

-

-

... More
SECURITY ROOM & MAIN GATE

4.06

-

-

... More
Supplying and fixing of Powder coated 50-60 microns approved colour of Aluminium 40mm Casement series Door Unit with suitable aluminium extrude profiles. the system is designed to accommodate 12mm clear toughened glass of make-Saint gobain/AIS/Gardian/modi. the rate quoted inclusive of hardwares like antilift,roller, Espag lock cum handle,epdm gaskets,T mullion ,Fly Mullion ,bottom adopter ,mid transom ,glazing clip for 12 mm glass felt along with all accessories etc complete. the gap between the wall and window will be filled with silicon weather sealant in the outer side. Casement Door Outer frame - 40mm x 45.3mm Series x 1.4mm thickness, Fly mullion - 44 x 60 mm x 1.4mm thickness, T Mullion 40 x 78.4mm x 1.4mm thickness, Transom - 40.28 x 125.8 x 1.75 mm thickness, Bottom adopter - 34.6 x 26 x 1.5mm thickness, including cost of all materials, all labour, sundries, T&P etc. complete in all respect as per direction of Engineer-in-Charge.(make-Jindal, Hindalco, schueco).

-

-

-

... More
BUILDING PROPER

-

-

-

... More
GROUND FLOOR (GD)

7.2

-

-

... More
Supplying and fixing of Powder coated 50-60 microns approved colour of Jindal aluminium 40mm Casement series Door Unit with suitable aluminium extrude profiles. the system is designed to accommodate 50% 6mm clear Toughen glass & 50% 4mm ACP Sheet in bottom. The quoted rate inclusive of hardwares like antilift,roller, Espag lock cum handle,epdm gaskets,glazing clip for 12 mm glass felt along with all accessories etc complete. the gap between the wall and window will be filled with silicon weather sealant in the outer side. Casement Door Outer frame - 40mm x 45.3mm Series x 1.4mm thickness, Fly mullion - 44 x 60 mm x 1.4mm thickness, T Mullion 40 x 78.4mm x 1.4mm thickness, Transom - 40.28 x 125.8 x 1.75 mm thickness ,Bottom adopter - 34.6 x 26 x 1.5mm thickness.including cost of all materials, all labour, sundries, T&P etc. complete in all respect as per direction of Engineer-in-Charge.(make-Jindal, Hindalco, schueco)

-

-

-

... More
BUILDING PROPER

-

-

-

... More
GROUND FLOOR (GD1)

11.52

-

-

... More
SECOND FLOOR (GD1)

23.04

-

-

... More
THIRD FLOOR (GD1)

23.04

-

-

... More
FOURTH FLOOR (GD1)

20.88

-

-

... More
LEAD LINE DOOR Supply & installation of Lead line door.Door Leaves Constructed from 1.20mm Thick Galvanized Steel Sheet formed to provide a 46mm thick fully flush, doubleskin door shell with Lock Seam joints at stile edges. In-fill of PUF including 2.0mm lead sheet (PolyUrethanes Foam) is used to give the required rigidity and effective acoustic and thermal insulation.DOOR FRAMES Produced from 1.6mm thick galvanized steel sheet formed to double or single rebate profile of size 143 x 57,105mm X 60mm. & 100 X 57mm and we are insert 2mm lead sheet in the door frame. The Door Frames maybe built into the brick or block walls using corrugated “ T ” anchors not welded to the Frames (First Fix).Frames may also be fixed on plastered openings with the help of Anchor Fasteners (Second Fix). Door Framesare supplied to knockdown from with butt joints for Bolted assembly at site.including cost of all materials, all labour, sundries, T&P etc. complete in all respect as per direction of Engineer-in-Charge.(make-Swathi,Steeltech,Metaflex)

-

-

-

... More
BUILDING

-

-

-

... More
GROUND FLOOR

4.32

-

-

... More
METAL FIRE DOOR :- Providing and fixing ISI Marked un-insulated fire rated door confirming to IS 3614:2021,& tested to IS17518,and shall carry a unique label with certification/test report number.The fire rating shall be for 120minutes integrity only.Material shall be galvanised steel conforming to IS 277, made out of minimum 1.2(18 SWG) for both frame and shutter, G.I. sheet (zinc coating 120 gsm/sqm).Frame shall be 125 x 55 grooved profile with built in rebate for fire rated smoke seal. Frame shall be mitered and field assembled. EPDM smoke seal to be provided along with frame as standard. Door shutter shall be double skin of 46mm thick with required fire rating and with vision panel. The infill material shall be resin bonded honeycomb core. All doorset shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks and door closers.The door stiles should be interlocked, for pairs of doors integral astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite, minimum 5mm clear fire rated glass of size 150 x 750mm (max 0.12sq.mt) on both shutters, fixing with clipon arrangement.

-

-

-

... More
All frame and door shutter shall be finished polyster powder coated to minimum 50microns, of approved colour as per the direction of the engineer incharge. Cost of double leaf doorset shall include following hardware and accessories as a complete assembly. SS ball bearing hinges of SS-304 grade of size100x75x3mm,1no Fire rated mortise dead lock, 55mm BS, 20mm sq. forend, including escutheion, sss as per EN 12209 with both side key cylinder on active leaf and 2nos flush bolt on the inactive leaf in case of double leaf door along with dust proof socket at bottom, 1pairs Pull handle D type, 22dia, CTC 300mm, back to back per leaf, with spindle,SS 304, SS finish. 1no of Door closer with spring size of EN 2- 4, as per EN1154 and CE marked per leaf. Suitable anchor fastners for fixing on different type of wall construction as per manufacturer recommendation.Once frames is installed it shall be filled with fire rated PUF. Manufacturer test certificates shall covers complete door set as a un-latched assembly with a valid test certificate not exceeding 5 years from the date of issue of report. for more info refer doors details drawings, including cost of all materials, all labour, sundries, T&P etc. complete in all respect as per direction of Engineer-in-Charge.(make-Shakti Hormannm,Tata pravesh)

-

-

-

... More
GROUND FLOOR (FIRE DOOR)

21.12

-

-

... More
FIRST FLOOR (FIRE DOOR)

38.4

-

-

... More
SECOND FLOOR (FIRE DOOR)

24

-

-

... More
THIRD FLOOR (FIRE DOOR)

21.12

-

-

... More
FOURTH FLOR (FIRE DOOR)

24

-

-

... More
OT DOOR :- Providing and fixing of OT Door frames must be formed of 1.2 mm thick Stainless Steel (SS) Grade 304 No.4 Finish sheet with a single rebate profile of 100 x 62 mm. Frames must be mitered or butt fastened, and field assembled using self-tabs or nuts and bolts. To receive the proper hardware, every provision should be mortised, drilled, and tapped. Back plate brackets and anchor fasteners should be included with frames for installation on a finished plastered masonry wall opening with Door leaf of 46mm thick double skin door is designed to fit flush into the wall panel system and is supplied in different dimensions. Doors are fabricated from 0.8mm Stainless Steel (SS) Grade 304 No.4 Finish sheets.

-

-

-

... More
The GI sheets are resin bonded with honeycomb core as an infill material. The doors are factory CNC fabricated with all necessary provisions for receiving hardware such as hinges, locks and door closers. Double Glazed View Panel of 5mm glass shall be provided as per requirement. For double leaf doors, integrated astragals must be provided on the meeting stile for both the active and inactive leaf. Optional hardware such as Single/Double Point Panic bars can be provided as per client requirement. Optional Infill of Rockwool can be provided for better insulation as per client requirement, Doors can also be internally lined with 2mm Lead sheet to prevent from radiations as an option. DOOR HARDWARE:-SS 304 Ball bearing Butt Hinges ,Door Closer,Mortise Locks ,SS 304 D’ Handle on both sides ,Single/ Double Point Panic Bar with External Trim ,Automatic drop bottom seal,Vision Panel (Double Glazed),including cost of all materials, all labour, sundries, T&P etc. complete in all respect as per direction of Engineer-in-Charge.(make-Swathi,Steeltech,Metaflex)

-

-

-

... More
GROUND FLOOR (OT DOOR)

4.32

-

-

... More
FOURTH FLOOR (OT DOOR)

17.28

-

-

... More
Supplying, fitting & fixing in all floors of M.S. grills, grill gates, M.S. gates, garage door, collapsible gates with top and bottom rails, steel windows, critical frames for windows, stair case and parapet railing made out of M.S Square bar/ flat including stair case hand railing with 40mm. dia G.I.pipe etc. including painting two coats over a coat of redoxide primer as per approved drawing and design with cost of all materials & labour, labour cess, T&P, sundries etc. complete in all respect as per specification & direction of the Engineer-in-Charge.

-

-

-

... More
GROUND FLOOR

6205.32

-

-

... More
1ST FLOOR

4873

-

-

... More
2ND FLOOR

5318.28

-

-

... More
3RD FLOOR

5533

-

-

... More
4TH FLOOR

4265.14

-

-

... More
HEAD ROOM

371.25

-

-

... More
SECURITY ROOM & MAIN GATE

877.26

-

-

... More
Finishing plastered surfaces of walls with cement based wall putty (Water based) of approved make (JK White/ Birla white or equivalent make duly approved by Engineer-in-Charge) and finishing the surface smooth and even by sand papering to receive painting in walls, at all heights with staging wherever necessary with cost, conveyance, cost of all labour,labourcess, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-charge.

-

-

-

... More
GROUND FLOOR

10352.79

-

-

... More
1ST FLOOR

8777.67

-

-

... More
2ND FLOOR

8657.33

-

-

... More
3RD FLOOR

7663.44

-

-

... More
4TH FLOOR

6595.39

-

-

... More
HEAD ROOM

1998.48

-

-

... More
SECURITY ROOM & MAIN GATE

634.2

-

-

... More
Priming one coat with wall cement primer (water bound) to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess T&P etc. complete as per the direction of the Engineer-in-charge. (Out Side) (Make: Asian/ Berger/ Dulex/ ICI or equivalent make duly approved by Engineer-in-Charge)

-

-

-

... More
GROUND FLOOR

11210.52

-

-

... More
1ST FLOOR

8777.67

-

-

... More
2ND FLOOR

9911.87

-

-

... More
3RD FLOOR

8922.75

-

-

... More
4TH FLOOR

8237.17

-

-

... More
HEAD ROOM

1998.48

-

-

... More
SECURITY ROOM & MAIN GATE

372.72

-

-

... More
COMPOUND WALL

968.76

-

-

... More
Wall painting two coats with Antifungal weather coat paint (1st quality) exterior grade of approved make & approved shade to make an even finished surface in all floors and heights with all scaffolding and staging charges including cost, conveyance, cost of all labours, T & P, sundries etc. as required for the work complete in all respect as per the direction of the Engineer-in-Charge. (Make: Asian/ Berger/ Dulux/ ICI or equivalent make duly approved by Engineer-in-Charge).

-

-

-

... More
GROUND FLOOR

2607.04

-

-

... More
1ST FLOOR

2141.9

-

-

... More
2ND FLOOR

1960.06

-

-

... More
3RD FLOOR

1703.9

-

-

... More
4TH FLOOR

1666.2

-

-

... More
HEAD ROOM

1169.09

-

-

... More
COMPOUND WALL

968.76

-

-

... More
SECURITY ROOM & MAIN GATE

372.72

-

-

... More
Painting two coats with plastic emulsion paint with a approved quality primer to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess, T&P etc. complete as per the direction of the Engineer-in-charge. Engineer-in-charge. (Make: Asian/ Berger/ ICI or equivalent make duly approved by Engineer-in-charge).

-

-

-

... More
GROUND FLOOR

7745.75

-

-

... More
1ST FLOOR

6146.35

-

-

... More
2ND FLOOR

6697.27

-

-

... More
3RD FLOOR

5959.54

-

-

... More
4TH FLOOR

3738.76

-

-

... More
HEAD ROOM

829.39

-

-

... More
SECURITY ROOM & MAIN GATE

146.9

-

-

... More
Painting two coat with approved synthetic enamel paint to new iron work over a coat of Red oxide primer including cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer in charge. (Make-Asian/ Berger/ICI or equivalent make duly approved by Engineer-in-charge).

-

-

-

... More
BUILDING

-

-

-

... More
GROUND FLOOR

143.19

-

-

... More
FIRST FLOOR

107.04

-

-

... More
SECOND FLOOR

120.87

-

-

... More
THIRD FLOOR

125.75

-

-

... More
FOURTH FLOR

96.94

-

-

... More
TERRACE FLOOR

14.85

-

-

... More
SECURITY ROOM AND GATE COMPLEX

29.48

-

-

... More
INTERNAL ROAD

512

-

-

... More
Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, cost of all labour,labour cess, T&P etc. required for the work complete in all respect as per direction of the Engineer-in-charge. (Make-JINDAL )

-

-

-

... More
BUILDING PROPER

-

-

-

... More
GROUND FLOOR

1970.45

-

-

... More
FIRST FLOOR

1970.45

-

-

... More
SECOND FLOOR

1970.45

-

-

... More
THIRD FLOOR

1970.45

-

-

... More
FOURTH FLOR

1970.45

-

-

... More
Providing 2.5cm thick Grading Concrete over roof slab with cement concrete (1:2:2) using 6mm size black hard granite crusher broken chips and screened & washed sharp sand for mortar and finished smooth to the rough surface of slab including watering and curing with cost, conveyance, royalties of all materials with cost of all labour, labour cess and T&P required for the work etc. complete in all respect as directed by the Engineer in charge.

-

-

-

... More
GROUND FLOOR

188.7

-

-

... More
THIRD FLOOR

233.34

-

-

... More
TERRACE FLOOR

1853.31

-

-

... More
Waterproofing application:- Providing and application of two component polymer modified flexible cementitious waterproofing coating at a thickness of 1.5 -2.5 mm The membrane should have Elongation equal or more than: 30% Crack Bridging ability : Up to 1 mm Adhesive strength: 1.0 N/mm² @ 28d Tensile elongation: 60% @ 20°C Shore A Hardness 85 (between 3 - 7 days) etc. as per direction of E.I.C (For longer span, in terrace panel of 4m*4m should be done by groove cutting, and filling with PU Sealant) (Make-Myk, Fosroc, Sika)

-

-

-

... More
BUILDING

-

-

-

... More
GROUND FLOOR

188.62

-

-

... More
THIRD FLOOR

233.34

-

-

... More
TERRACE FLOOR

1853.31

-

-

... More
Supply and Installation of 14 mm GRG Tiles steppe edge ceiling tile of size 595 x 595 x 14 mm on the edge & 7 mm in the center having all edges encapsulated with chemical treated paint & having densified tegular edge ,weight 5 kg/m2 having random circular semi perforated in dual diameter / Random fissure semi perforated in variable length which is suspended by using 0.3 mm thick and 15 mm wide pre coated metal T 15 grid system. The technical parameters are as follows : Core - GRG Silicate, Fire – Class 1 & P , Acoustics – NRC 0.5,Climate (degree C, RH) – 50, 99, STC - 30, Termite resistance ,Light reflectance – 85 %,Green (RC %) – 25, Hygiene (VoC, Clean room) – Low, , Load capacity (Kg) - Antisag. The T 15 Grid system of 600 x 600 mm module shall include wall angle(WA 15) with unequal flanges of size 14 x 20 x 3000 mm wide, length 3000 mm, 0.43 mm thick fixed along the perimeter of wall with the help of nylon sleeves and suitable fasteners at 300 mm centers. Then suspend the Main T15 (MT15 W36) having flange width 15 mm /24 mm , height 32/38 mm and length 3600 mm thickness 0.30 mm from the soffit with help of soffit cleat and wire at 1200 mm c/c. Cross T15 (CT15 W12) with flange width 15 mm, height 32 mm and length 1200 mm is then interlocked into the pre-cut slots in the Main T15 at 600 mm centers in the direction perpendicular to the Main T15. Finally, Cross T15 (CT15 W06) having flange width 15 mm, height 32 mm and length 600 mm are then interlocked into the pre cut slots in the 1200 mm Cross T15 at 1200 mm centers and in direction parallel to the Main T15. GRG Tile of size 595 x 595 x 14 mm thick shall be placed into the grid size of 600 x 600 mm. Ensure arrow marks behind panels are oriented in one direction to achieve uniform shade. Test certificate will be submitted after procurement of materials

-

-

-

... More
GROUND FLOOR

1778.02

-

-

... More
1ST FLOOR

1503.42

-

-

... More
2ND FLOOR

1101.16

-

-

... More
3RD FLOOR

1100.16

-

-

... More
4TH FLOOR

751.71

-

-

... More
Supply and installation of Stainless steel ceilings are the safest when it comes to sanitizing and disinfecting. So easy to wash and wipe often and the results visible to all from housekeeping to auditors to patients and doctors alike. Well, Serge Astral SS does duty in this ICU. Clip-in tiles, Sj having 600x600x0.6mm having weight 2kg/m2, square edge, bulkheads made up of SS Material sheets installed in ceiling using Spring-T system.Spring-T system of 600x600mm module includes Skelet WA15W30, sectional thickness 0.4mm, with unequal flanges of 15/19mm, length 3000mm, fixed along the perimeter of walls with the help of nylon sleeves and suitable fasteners at 300mm centers. Then Hold-on ceiling clamp hung from the soffit at 600mm centers bothways with Hanger rod and soffit cleat.Strut Spring-T is then held in position by hold-on clamp @ every 600mm centers. Astral Plus Clip-in ceiling tiles 600x600x0.6mm are then clipped into Spring-T."Technical Parameters. Fire (Class) - A. Acoustics - nil (For E300 Mounting) • Thermal conductivity (W/mk)- na. Climate (°C, RH) - 50, 99. Light reflectance (%) -75. Green (VOC, RC %) - Low, 25, Finish-M HAS Anti Bacterial H+V+, including cost of all materials, all sundries, T&P etc. complete in all respect as per direction of Engineer-in-Charge

-

-

-

... More
GROUND FLOOR

92.95

-

-

... More
2ND FLOOR

221.94

-

-

... More
3RD FLOOR

59.05

-

-

... More
4TH FLOOR

331.91

-

-

... More
Supplying and Installing of Expoband one Flexible Polyolefin (FPO) membrane system which is designed to be bonded over expansion and movement joints up to 150mm in structures to prevent the passage of water having Elongation at break : 400%,Tensile Strength : 12.5N/mm2 (DIN EN 12311-2 Method B),Water vapour permeability : 2.7g/Sqm/day (DIN EN 1931-Method B). It is bonded in position using two-part epoxy adhesive, Nitobond PC40 as per manufacturer direction after proper fixing of the necessary backup materials as specified and directed by the Engineer In-charge. The item rate shall be including of all kinds of labour, tools & tackle, machineries, lead & lift, mathadi charges, curing, wastages, consumable, cleaning, shifting of debris outside the site premises, surface preparation etc. complete as per design, drawing & instructions of EIC.(make-Myk,Fosroc,Sika)

-

-

-

... More
BUILDING PROPER

-

-

-

... More
GROUND FLOOR

13.38

-

-

... More
FIRST FLOOR

10.98

-

-

... More
SECOND FLOOR

16.45

-

-

... More
THIRD FLOOR

10.98

-

-

... More
FOURTH FLOOR

10.98

-

-

... More
TERRACE FLOOR

10.67

-

-

... More
Providing fitting and fixing up partition walling OEL aluminum anodized section No.9210 and 9207 as single groove and double groove respectively as horizontal and vertical member and OEL section 4660 as Tapered clip for fixing up 6mm thick Black Glass and jointing angle No. 1855 etc. as per direction of Engineer-in-charge

-

-

-

... More
EXTERIOR FACADE

43.2

-

-

... More
Loosening to a depth of 150mm, leveling and compacting original ground supporting embankment /sub-grade as per approved drawing and technical specifications as per Section 900 and Clause 305, 305.3.4 of MoRT&H Specification for Road & Bridge works (5th Revision) and as per direction of Engineer-in-Charge.

-

-

-

... More
INTERNAL ROAD

367.5

-

-

... More
Construction of granular sub-base by providing Close graded Granular subbase Grading-III material as per table 400-1, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density complete as per Clause 401 of MoSRT&H Specifications for Road & Bridge works (4th Revision)

-

-

-

... More
INTERNAL ROAD

490

-

-

... More
Supplying and fixing of 80mm thick cement concrete interlocking paver block of M-40 grade of approved make, design, colour and size made by Block making machine with proper compaction laid in required pattern etc. complete in all respect conforming to IRC SP-63:2018 as per direction of the Engineer-in-charge.

-

-

-

... More
INTERNAL ROAD

2450

-

-

... More
Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M-10 grade foundation 150mm thick, foundation having 50mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408 including cost of all materials, labour, T&P, royalty etc complete in all respect and as per direction of the Engineer-in-charge.

-

-

-

... More
INTERNAL ROAD

640

-

-

... More
E.I. WORK Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/ Norpak/ Anchor/Kinjal 6A modular type (anti bactorial & flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) (anti bactorial & flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.

-

-

-

... More
GROUP-A

400

-

-

... More
GROUP-B

340

-

-

... More
GROUP-C

1650

-

-

... More
Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( (anti bactorial & flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.

326

-

-

... More
Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( (anti bactorial & flame retradant type)) with suitable size modular box & cover(anti bactorial & falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.

413

-

-

... More
Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)((anti bactorial & flame retradant type)) with suitable size modular box & cover(anti bactorial & flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.

300

-

-

... More
Supplying,fixing of 1x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+1 no 6A switch & socket(modular type) ( (anti bactorial & flame retradant type) with suitable size modular box & metallic cover plate (both side)(anti bactorial & falme retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN)/Panasonic (vision) (For equipement power)(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.

102

-

-

... More
Supplying,fixing of 3x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+3 nos 6A switch & socket(modular type) ( (anti bactorial & flame retradant type) with suitable size modular box & metallic cover plate (both side)(anti bactorial & falme retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. Make-Schneider (Zencelo)/ legrand( ( Myrius-NEXT GEN)) /Panasonic (vision) (For equipement power). (Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.

20

-

-

... More
Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ Norpak/ Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5)

5244

-

-

... More
Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/RR KABLE in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ Norpak/ Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5)

17800

-

-

... More
Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ Norpak/ Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5)

6522

-

-

... More
Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS /RR KABLE in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ Norpak/ Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit .(LFDB TO LBDB/UBDB) (2X6+1X2.5)

2588

-

-

... More
Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ Norpak/ Anchor/Kinjal as required as per direction of Engg.-in-Charge. 4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit.(LFDB TO LBDB/Medical equipement) (4X6+2X4)

2055

-

-

... More
Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/ Norpak/ Anchor/ Kinjal as required as per direction of Engg.-in-Charge. 4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit .(LFDB TO FLOOR PANEL TO TPN BDB power) (4X10+2X6)

1988

-

-

... More
Supplying and fixing 32 amps, 240 volts, SPN, industrial type socket outlet, with 2 pole and earth metal enclosed plug top along with 32 amps. C-series, SP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet, and complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge.. . Make-Legrand/Schneider/Siemens ISI marked as approved,All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.(for equipement only & split AC at required area)

16

-

-

... More
Supplying and fixing of following sizes of HMS PVC FRLS conduit ISI marked along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per direction of Engg.-in-Charge .Make-AKG/ Norpak/ Kinjal. (Only for data, telephone, CCTV)

-

-

-

4900

-

-

4900

-

-

... More
Supplying and installation of 25A AC starter Modular type, Schneider/Siemens/Legrand coil voltage-230 Volt A.C. on mod Box of suitable size including modular coveras required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.

20

-

-

... More
Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover.Make-Schneider (Zencelo)/ legrand( ( Myrius-NEXT GEN)) /Panasonic (vision)as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.

24

-

-

... More
S/F of Bakelite angle holder/batten holder (make-Anchor/Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.

44

-

-

... More
Sub-Head II (Light fitting Fixture & Fan)

-

-

-

... More
Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years.

60

-

-

... More
Supplying, installation, of exhaust fan of heavy duty 380 mm sweep 1400 rpm with louvers(Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection .as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years.

60

-

-

... More
Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.. .(With fan Regulator)

605

-

-

... More
Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years

1275

-

-

... More
Supplying and fixing of Energy efficient Recess /Surface mounted square/round shaped LED luminaire made up of CRCA powder coated sheet steel of 25W (595mm x 595 mm x70mm) and system lumens output not less than 3250 lumens (130 lm/ wt) with diffusers for better light transmission and pure effect with High luminous flux LEDs for better light output, CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (5 years warranty)supply .as required as per direction of Engg.-in-Charge (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) . The luminaire must be Replacement Warranty will be 5 years.

160

-

-

... More
Supplying an fixing of recess/surface mounted 2'x2' 36 W(595mmx595mmx70mm) square shaped LED with lumen efficacy not less than 130lm/W, CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (5 years warranty) as required as per direction of Engg.-in-Charge (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) . The luminaire must be Replacement Warranty will be 5 years.

400

-

-

... More
SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years .

200

-

-

... More
SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years

120

-

-

... More
Supplying and fixing of Energy efficient recessed mounted LED luminaire made up of CRCA powder coated housing, Top opening clean room LED luminaire of 595mm x 595 mm x70mm size with of 45 W and system lumens output not less than 4500 lumens , IP65 ,dust free & zero maintenance , anti glare high transmittance PMMA diffuser , operating volatge range 150-265 V, high performance potentiometric electronic driver for zero maintenance , 2.5 KV internal urge protection, L70 B 50: 50,000 hrs., CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,,IP 65 protection complete with all other accessories suitable for operation on 230 V, 50 Hz supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2years. .CLEAN ROOM FITTING for OT.

20

-

-

... More
Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge . (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved.

788

-

-

... More
BDBS,DB,AC DB,FLOOR PANELS,MCBS

-

-

-

... More
Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9 as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years.

-

-

-

... More
4 Way(8+4+12+12) Way TPN MCB DD 7 Segment DB Horizontal Type as per IEC 61439-3 with configuration of incomming I-8 modules,incomming II-4 modules,sub incommer-12 module & out going-12 modules,suitable for Flush mounting and Surface mounting with Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years

20

-

-

... More
Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years

20

-

-

... More
2+4 way MCB Enclosure DB (GLAZED door)(only each EM. CONNECTION UPS LOAD)Warranty on DB is 3 years

8

-

-

... More
8 Way(8+4+12+24) Way TPN MCB DD 7 Segment DB Horizontal Type as per IEC 61439-3 with configuration of incomming I-8 modules,incomming II-4 modules,sub incommer-12 module & out going-24 modules,suitable for Flush mounting and Surface mounting with Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years

20

-

-

... More
Supplying and fixing 20 amps rating, 240 volts, C series,10KA breaking capacity, Double poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 3 years.

12

-

-

... More
Supplying and fixing 6-32 Amps rating, C series,10KA breaking capacity,SP, 230 volts, MCB . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 3 years..

888

-

-

... More
Supplying and fixing 40 amps rating, 415 volts, C series,10KA breaking capacity, FOUR poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 3 years.

20

-

-

... More
Supplying and fixing 40 Amps rating,C series,10KA breaking capacity, 4P, 415 volts, RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 3 years.

20

-

-

... More
Supplying and fixing 40 Amps rating,C series,10KA breaking capacity, 2P, 240 volts, RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 3 years.

80

-

-

... More
Supplying and fixing 63 Amps rating,C series,10KA breaking capacity, 2P, 240 volts, RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 3 years.

60

-

-

... More
Supplying and fixing 63Amps 4P 415 volts MCB Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB with connections as per direction of Engg.-in-Charge..Warranty on MCB is 3 years.

20

-

-

... More
Supplying and fixing 63Amps 4P 415 volts RCCB 30 mA Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..The RCCB should be Replacement Warranty will be 3 years.

20

-

-

... More
Supplying and fixing 40 amps rating, 240 volts, C series,10KA breaking capacity, Double poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 3 years.

20

-

-

... More
Supplying and fixing of Type (I +II) 3P+N SPD with Lightening impulse discharge current I imp(10/350) µs 7kA/POLE and 25kA total and maximum discharge current Imax(8/20) msec-50kA,with response time25 nanosec in the incommer of Distribution board, Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB with connections as per direction of Engg.-in-Charge.The SPD should have Replacement Warranty will be 3 years.

40

-

-

... More
(Earthing) INSTALLATION

-

-

-

... More
Supplying,installation,testing & commissioning Of Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (WITH charcoal and salt) as required as per direction of Engg.-in-Charge.

10

-

-

... More
Supplying,installation,testing & commissioning of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.The entire earthing system should be Replacement Warranty will be 2 years

10

-

-

... More
Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. Tapping from 50mm x 6 mm bus bar to all sub panel

655

-

-

... More
Providing and fixing 25mm x 5 mm copper strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. Main LT ROOM dg panel earthing

355

-

-

... More
Providing and fixing 50mm x 5 mm copper strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. MainLT ROOM dg panel earthing.

288

-

-

... More
Providing and fixing 50mm x 6 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. 2 runs from main LT room to electrical shaft upto 5th floor

100

-

-

... More
CABLING AND END TERMINATION MAIN AREA

-

-

-

... More
Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/ Polycab/ HAVELLS/ RR KABLE/ Gloster of following size cables as per direction of Engg.-in-Charge.

-

-

-

... More
3.5core x 300 sq mm

138

-

-

... More
3.5core x 240 sq mm

120

-

-

... More
3.5core x 150 sq mm

150

-

-

... More
3.5core x 95 sq mm

155

-

-

... More
3.5core x 70 sq mm

120

-

-

... More
4core x 16 sq mm

200

-

-

... More
4 core x 6 sq mm

223

-

-

... More
3.5core x 35 sq mm

88

-

-

... More
LAYING OF CABLE

-

-

-

... More
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.

122

-

-

... More
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.

124

-

-

... More
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 120 SQ. MM but not exceeding 400 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.

370

-

-

... More
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge.

200

-

-

... More
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge.

134

-

-

... More
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in open duct etc as required as per direction of Engg.-in -charge.

156

-

-

... More
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM in open duct 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge.

166

-

-

... More
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge.

122

-

-

... More
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 120 SQ. MM From 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge.

66

-

-

... More
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 400 SQ. MM From 120 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge.

66

-

-

... More
Supplying and making end termination with brass double compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge.

-

-

-

... More
3.5 core x300 sq mm

12

-

-

... More
3.5 core x240 sq mm

10

-

-

... More
4 core x16sq mm

10

-

-

... More
3.5 core x35 sq mm

10

-

-

... More
3.5 core x95 sq mm

20

-

-

... More
3.5 core x150 sq mm

8

-

-

... More
3.5 core x70 sq mm

8

-

-

... More
Providing,fixing and laying of following dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge.

-

-

-

... More
50 mm dia

42

-

-

... More
Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge.

-

-

-

... More
200 mm dia

200

-

-

... More
PANELS

-

-

-

... More
FLOOR POWER PANEL (1F, 2F, 3F, 4F, STP, LAUNDRY, AHU,VENTILATION )

-

-

-

... More
S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. (FOR ALL MAIN CONNECTED LOAD) BUILDING POWER)as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 3 years & compelete test certificate must be submitted along with panel board including component list.Type 2 SPD 40 kA with 63A 4P MCB,10kA, Cseries shall be installed in the incomer. 40X10MM Separate Aluminium Earth bus bar should be installed. In commer-01 number of 250 Amps 4P onload type Changeover (Make-C&S/LK/Siemens/Schneider/Legrand) Busbar- 04 numbers of 400Amps 50kA Electrolytic copper busbar duly sleeved by color coaded PVC sleeve & supported by suitable size DMC insulator. Out going- (i) 63A 4P MCB 10kA,C series 08 NOS FOR POWER BDB( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9) Out going- (ii) 04 nos 32A 4P MCB 10kA,C series LIGHT BDB AC IDU BDB/LIGHT BDB( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9) Instrument- (i) 3 numbers phase indicating lamp with 2A SP MCB,C,10KA. (ii) 01 set of MFM with RS-485 & CTS.(DIGITAL)(Sicure/L&T,CT-KAPPA or equievalant make & model)

8

-

-

... More
FLOOR PANEL POWER RIGHT WING(OT FLOOR)

-

-

-

... More
S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. (FOR ALL MAIN CONNECTED LOAD) BUILDING POWER)as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 3 years & compelete test certificate must be submitted along with panel board including component list.Type 2 SPD 40 kA with 63A 4P MCB,10kA, Cseries shall be installed in the incomer. 40X10MM Separate Aluminium Earth bus bar should be installed. In commer-01 number of 250 Amps 4P onload type Changeover (Make-C&S/LK/Siemens/Schneider/Legrand) Busbar- 04 numbers of 300Amps 50kA Electrolytic copper busbar duly sleeved by color coaded PVC sleeve & supported by suitable size DMC insulator. Out going- (i) 63A 4P MCB 10kA,C series 4 NOS FOR POWER BDB( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9) Instrument- (i) 3 numbers phase indicating lamp with 2A SP MCB,C,10KA( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9). (ii) 01 set of MFM with RS-485 & CTS.(DIGITAL)(Sicure/L&T,CT-KAPPA or equievalant make & model)

1

-

-

... More
FLOOR LIGHT PANEL(1F,2F,3F,4F ,LIFT,)

-

-

-

... More
S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. (FOR ALL MAIN CONNECTED LOAD) BUILDING LIGHT)as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 3 years & compelete test certificate must be submitted along with panel board including component list.Type 2 SPD 40 kA with 63A 4P MCB,10kA, Cseries shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed. In commer-01 number of 125 Amps 4P onload type Changeover (Make-C&S/LK/Siemens/Schneider/Legrand) Busbar- 04 numbers of 200Amps 50kA Electrolytic copper busbar duly sleeved by color coaded PVC sleeve & supported by suitable size DMC insulator. Out going- (i)32A 4P MCB 10kA,C series 08 NOS FOR EM. POWER BDB( ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9) Out going- (ii) 04 nos 32A 2P MCB 10kA,C series POWER BDB AC IDU /LIGHT BDB( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9) Instrument- (i) 3 numbers phase indicating lamp with 2A SP MCB,C,10KA. (ii) 01 set of MFM with RS-485 & CTS.(DIGITAL)(Sicure/L&T,CT-KAPPA or equievalant make & model)

6

-

-

... More
MAIN CONTROL PANEL AT SERVICE AREA

1

-

-

... More
S/I/T&Commissioning of LT indoor floor mounted(Totally type tesed standard) TTA IEC:61439-I &II cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by siemens gray powder cote paint is designed as G.A drawing as per direction of Engg.-in-Charge.Warrentee period of replacement of panel & accessories must be with compelete test certificate must be submitted along with panel board including component list.Make of main LT panel-Schneider(PRISMA)/SIEMENS(SIVACON)/ABB(R2K) 80X10MM Separate Aluminium Earth bus bar should be installed.Warrentee period of replacement of panel & accessories must be 3 years & compelete test certificate must be submitted along with panel board including component list. In commer-1- 02 number 4p 1250A EDO TYPE ACB with 1. Micro Processer Based with Breaking(with earth leakage relay) capacity - Icu= Ics= Icw= 50kA for 1 sec having LSING Protection with Display-Current Metering with Last Trip Record Data. (Communication with On & Off Status indication for Remote Closing and Opening operation of breakers through Modbus RS485 protocol and uploading breaker status to Users Computer/SCADA.) & Electrical locking for normal & DG.Make-Schneider(MASTERPACT )/Siemens(3WT)/Legrand(DMX SP) (WITH AXULARY FOR BMS) With On/Off/Trip Indication with TNC switch(750 KVA TRANSFORMER 2 NOS).

-

-

-

... More
In commer-2- 02 number 4p 800A EDO TYPE ACB with 1. Micro Processer Based with breaking (with earth leakage relay) capacity - Icu= Ics= Icw= 50kA for 1 sec having LSING Protection with Display-Current Metering with Last Trip Record Data. (Communication with On & Off Status indication for Remote Closing and Opening operation of breakers through Modbus RS485 protocol and uploading breaker status to Users Computer/SCADA.) & Electrical locking for normal & DG.Make-Schneider(MASTERPACT )/Siemens(3WT)/Legrand(DMX SP) (WITH AXULARY FOR BMS) With On/Off/Trip Indication with TNC switch(500 KVA DG 2 NOS). BUS COUPLER-1- 01 number 4p 1250A EDO TYPE ACB with 1. Micro Processer Based with breaking (with earth leakage relay) capacity - Icu= Ics= Icw= 50kA for 1 sec having LSING Protection with Display-Current Metering with Last Trip Record Data. (Communication with On & Off Status indication for Remote Closing and Opening operation of breakers through Modbus RS485 protocol and uploading breaker status to Users Computer/SCADA.) & Electrical locking for normal & DG.Make-Schneider(MASTERPACT )/Siemens(3WT)/Legrand(DMX SP) (WITH AXULARY FOR BMS) With On/Off/Trip Indication with TNC switch.

-

-

-

... More
1 No PLC based Logic controller Comprising of

-

-

-

... More
1 No - PLC based logic contrller for 2 nos of DG & 2 no of Transformer,EM DG with auto syncronisation, auto load sharing & energy monitoring system. Busbar-1&2 04 numbers of 1600Amps Aluminium busbar with 1A/SQ.MM current carring capacity. busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing). Out going- 02 numberof 630A 4P MCCB(400-630) with ROM 36kA with adjustable Micro processor Release with Ics=100% Icu. ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS)with shunt trip.with axulary for BMS (SPARE,VRF )With On/Off/Trip Indication. Out going- 03 number of 630A 4P MCCB(600-630) with ROM 36kA with adjustable Micro processor Release with Ics=100% Icu. (make- Equievalant LSING ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS)with shunt trip.with axulary for BMS (BUS RISER power )With On/Off/Trip Indication Out going- 02 numbers of 400A(320-400) 4P MCCB with ROM 36kA with adjustable MICRO PROCESSOR Release with Ics=100% Icu. ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS)with shunt trip.with axulary for BMS (HVAC & light,BUS BAR TRUNKING LIGHT,SPARE,KITCHEN)With On/Off/Trip Indication.

-

-

-

... More
Out going- 4 numbers of 100A(80-100) 4P Icu=100%Ics, LSIG MCCB with adjustable Thermal Magnetic Release with Ics=100% Icu. (make- Equievalant LSIG model of ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider-CVS)with shunt trip.with axulary for BMS(with on/off indication) . Out going- 4 numbers of 125A(100-125) 4P Icu=100%Ics, LSIG MCCB with adjustable Thermal Magnetic Release with Ics=100% Icu. (make- Equievalant LSIG model of ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider-CVS)with shunt trip.with axulary for BMS(with on/off indication) . Out going- 3 numbers of 250A(100-250) 4P Icu=100%Ics, LSIG MCCB with micro processor based release with adjustable overload 36KA ,( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS)(Utility,fire,STP,Spare)With On/Off/Trip Indication. Out going- 8 numbers of 32A 4P MCB10KA,C series ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9)(LIGHT SUPPLY) ,8 numbers of 63A 4P MCB ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9)(POWERSUPPLY) Out going- 1 numbers of 250A(100-250) 4P Icu=100%Ics, LSIG MCCB with micro processor based release with adjustable overload 36KA along with 250A 4P contactor with axularies ,( Make-/L&T(MCX TYPE//Legrand(eq.)))(Utility,fire,STP,Spare)With On/Off/Trip Indication.

-

-

-

... More
Instrument- (i) 36 SETs phase indicating lamp with 2A SP MCB,C,10KA.. (ii) 24 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication with RS 485 COMPACTIVITY FOR bms data. (iii)1 SET 65kA 3P+N SPD WITH 63A 4P MCB,10 kA Cseries (iv)Announciation system,auto load manager with sysnchronization with DG NB- This panel should have proper earth by suitable rated copper flat.

-

-

-

... More
MAIN 60 KVA UPS EMERGENCY PANEL

1

-

-

... More
S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. (FOR ALL MAIN CONNECTED LOAD) BUILDING EMERGENCY)as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 3 years & compelete test certificate must be submitted along with panel board including component list.Type 2 SPD 40 kA with 63A 4P MCB,10kA, Cseries shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed. In commer- 02 number of 125 (100-125)Amps 4P MCCB,LSIG with ROM ,25kA with adjustable Thermal Magnetic Release with Ics=100% Icu. (make- Equievalant LSING model of ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS)with shunt trip.with axulary for BMS(with on/off indication) . Busbar- 04 numbers of 200Amps 50kA Electrolytic copper busbar duly sleeved by color coaded PVC sleeve & supported by suitable size DMC insulator. Out going- (ii) 5 nos 63A 4P MCB 10kA,C series UPS PAENL EACH FLOOR,ICU BDB /EM LIGHT BDB( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9) Out going- (i) 02 NOS OF 100A(63-100)Amps 4P MCCB,LSIG with ROM ,25kA with adjustable Thermal Magnetic Release with Ics=100% Icu. (make- Equievalant LSIG model of ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider-CVS)with shunt trip.with axulary for BMS(with on/off indication) . Instrument- (i) 4 sets phase indicating lamp with 2A SP MCB,C,10KA. (ii) 02 set of MFM with RS-485 & CTS.(DIGITAL)(Sicure/L&T,CT-KAPPA or equievalant make & model) (iii)2 SETS. 3P+N 65kA/POLE type 1+2 SPD with 63A rating,10KA breaking capacity ,4P MCB(TYPE-I)(Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9)

-

-

-

... More
FLOOR UPS PANEL & ,OT,ICU

-

-

-

... More
S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. (FOR ALL MAIN CONNECTED LOAD) BUILDING EMERGENCY)as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 3 years & compelete test certificate must be submitted along with panel board including component list.Type 2 SPD 40 kA with 63A 4P MCB,10kA, Cseries shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed. In commer- 01 no 63 A 4P MCB 10kA,C series with on/off trip indication Light load for each floor. ( Make-LEGRAND DX3/ Siemens-Betaguard/ Schneider- Acti 9 ). Busbar- 04 numbers of 100Amps,50kA Electrolytic copper busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator. Out going- 6numbers of 32A 4P MCB 10kA,C series( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9). Out going- 4numbers of 32A DP MCB 10kA,C series( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9). Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse. (ii) 01 set of 0-60Amps MFM with CTS.(DIGITAL)(Sicure/L&T,CT-KAPPA or equievalant make & model).

5

-

-

... More
FDB EQ.-CSSD,XRAY,WASHING

-

-

-

... More
S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. (FOR ALL MAIN CONNECTED LOAD) BUILDING LIGHT)as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 3 years & compelete test certificate must be submitted along with panel board including component list.Type 2 SPD 40 kA with 63A 4P MCB,10kA, Cseries shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed. In commer- 01 no 63 A 4P MCB 10kA,C series with on/off trip indication Light load for each floor. ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9). Busbar- 04 numbers of 32Amps,50kA Electrolytic copper busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator. Out going- 3 numbers of 32A 4P MCB 10KA,C series ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9). Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse. (ii) 01 set of 0-60AmpsMFM with CTS.(DIGITAL)(Sicure/L&T,CT-KAPPA or equievalant make & model).

2

-

-

... More
HVAC ODU PANEL,COM.

-

-

-

... More
S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. (FOR ALL MAIN CONNECTED LOAD) BUILDING LIGHT)as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 3 years & compelete test certificate must be submitted along with panel board including component list.Type 2 SPD 40 kA with 63A 4P MCB,10kA, Cseries shall be installed in the incomer. 60X10MM Separate Aluminium Earth bus bar should be installed. In commer- 01 number of 400A 3P+N MCCB,36 Ka with under voltage,over voltage ,current,earth fault protection ( Make-LEGRAND-DPX3 DB/ Siemens-3VA Model/ Schneider- CVS). Busbar- 04 numbers of 800Amps Electrolytic copper busbar duly sleeved by color coaded PVC sleeve & supported by suitable size DMC insulator. Out going- (i) 63A 4P RCBO,300MA 12NOS FOR OUT DOOR UNIT ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9). Out going- (i)32A 4P RCBO,300mA 8NOS FOR OUT DOOR UNIT ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9). Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse. (ii) 01 set of digital type multifunction meter with CT for voltage, current, frequency, PF, THD indication.

2

-

-

... More
CABLE TRAY /RACE WAY FOR DISTRIBUTION OF POWER

-

-

-

... More
Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge.

144

-

-

... More
Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 300mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge.

144

-

-

... More
Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 400mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge.

122

-

-

... More
Supplying,fixing of FLOOR RACE WAY WITH JUNCTION box GALVANIZED(GC) type AS PER EN-ISO-1461 , with internal dimensions of size 38mm(H) x 225mm(W), of MAKE- Profab/OBO/Neidax .(With all accessories,bend,cover,supporter)WITH REQUIRED SIZED JUNCTION BOX ,COVER CONNECTOR as required as per direction of Engg.-in-Charge.(3 COMPARTMENT TOTAL 54 MM HEIGHT.

122

-

-

... More
FLOOR RISING MAIN SYSTEM

-

-

-

... More
Supplying, installing on wall or suspension on ceiling, testing and commissioning of following capacity Air insulated compact. Type Bus Trunking with reducer required for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with metal clad enclosure having IP-55 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessary joints, elbow joints & expansion joints, fire barrier at each floor, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required.Make-Legrand/Schneider/Siemens/ABB/C&S

-

-

-

... More
630 A Isc = 50kA for 1 second(with reducer as per requirement)

40

-

-

... More
Supplying, installation, testing & commisioning of following capacity End Feed Unit for the existing Air insulated compact. Type bus trunking/ rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick steel sheet enclosure (IP54) duly powder coated with provision of MCCB/ACB (but without MCCB/ACB) complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required.Make-Legrand/Schneider/Siemens/ABB/C&S

-

-

-

... More
630 A 50kA SC for 1 sec

2

-

-

... More
Supplying, installation, testing & commisioning of following capacity Plug In/ tap off box on the existing rising mains for use on 3 phase 4wire 415 volts, 50Hz A.C. supply made with 1.6mm thick sheet steel enclosure (IP54) duly powder coated without MCCB ( complete etc. as required,as per the direction of Engg-in-charge completely Type Tested at NABL Accredited Laboratories as per latest IEC 61439 - 1&6 (Type Test Certificates must be submitted). Busbar to be insulated with multilayered Class F (155 Deg C) PET insulation.Warrentee period must be 5 years & compelete test certificate must be submitted .Make-Legrand/Schneider/Siemens/ABB/C&S

-

-

-

... More
250A 36kA SC for 1 sec

8

-

-

... More
125A 36kA SC for 1 sec

8

-

-

... More
100A 25kA SC for 1 sec

4

-

-

... More
20 PASSENGER BED CUM HOSPITAL LIFT WITH WIRRING(1.1)

-

-

-

... More
Supply,Installation, Testing & Commissioning of of 20 Passenger-cum-bed lift gearless with Machine room Capacity(1360 Kg), with minimum shaft size of 2100mm(Left to right)x2900mm(Front to back) Elevator G+4 Floors with ACVVVF drive/Control with ARD =1.00 MPS, SS honeycomb interior ,2hr fire rated door with simplex operation without attendant car position indicators,battery operated alarm bell & emegency light,SS honeycomb finish door finished car interior, recess Granite flooring ,power operated centre opening automatic sliding SS honeycomb finish doors for car entrance & hoist way entrance etc .All SS material shall be of grade SS-304 and minimum thickness of 2.00mm. Machine beams,buffer support channels,facia plate including sills pit ladder metal screen in Elevator pit etc.as per specifiaction including cost of (i)Overload detection,(ii)Voice announcement,(iii) Intercom,(iv)Braille Buttons with all Civil & Electrical works required for installation of Elevator in the existing lift well and machine room,scaffolding ,floor cutting including Fireman's switch complete in all respec as per the instruction of Engg. in charge.The Elevator should be suitable for physically handicapped person. Make:OTIS/ Mitsubishi/ Schindler

1

-

-

... More
Supply,Installation, Testing & Commissioning of of 13 Passenger lift(884 Kgs) gearless with Machine room Capacity,with minimum shaft size of 2450mm(Left to right)x1700mm(Front to back) Elevator G+4 Floors with ACVVVF drive/Control with ARD =1.00 MPS, SS honeycomb interior ,2hr fire rated door with simplex operation without attendant car position indicators,battery operated alarm bell & emegency light,SS honeycomb finish door finished car interior, recess Granite flooring ,power operated centre opening automatic sliding SS honeycomb finish doors for car entrance & hoist way entrance etc . All SS material shall be of grade SS-304 and minimum thickness of 2.00mm.Machine beams,buffer support channels,facia plate including sills pit ladder metal screen in Elevator pit etc.as per specifiaction including cost of (i)Overload detection,(ii)Voice announcement,(iii) Intercom,(iv)Braille Buttons with all Civil & Electrical works required for installation of Elevator in the existing lift well and machine room,scaffolding ,floor cutting including Fireman's switch complete in all respect as per the instruction of Engg. in charge.The Elevator should be suitable for physically handicapped person. Make:OTIS/ Mitsubishi/ Schindler

1

-

-

... More
500 KVA DG(main)

-

-

-

... More
Supply, Transportation, erection, testing and commissioning of 3 Phase, 415V, 50Hz, water cooled multi cylinder diesel generator set with alternator of 500KVA ( Make -Kirloskar / Jakson/Mahindra) out put contineous rating directly coupled Engine and Alternator with guard and mounted on a common base plate of Robust construction and complete with AMF panel having IP-52 protection, Acoustic Enclosure as per CPCB IV+ norms , sound absorbing material, to restrict sound level up to 75 dB up to 1 mtr distance and as per CPCB IV + norms etc as per following specifications mentioned below. Warrentee period of panel must be 2 years. (a) ALTERNATOR:The alternator of the output rating shall be 3 Phase, 415V, 50Hz, Ac , 0.8 P.F. lagging at 1500 RPM. The alternator is self excited, self regulated, and shall confirm to IS: 13364 of 1992 with regulation of +5% from no load to full load. degree of protections shall be IP21. (b) ENGINE:. Diesel Engine start, developing suitable BHP output at 1500 RPM with mechanical / electronic governing so as to enable the alternator to give 500KVA continuous output at 0.8 P.F. lagging at NTP conditions. The diesel engine shall be capable of providing 10% O/L for 1 Hr for every 11 Hrs of continuous running at full load. The engine with 1st filling of oil and Diesel etc. 01. Exhaust pipe of required size and length with insulation or clading. 02. Diesel tank suitable for 8 to 12 Hours running capacity. 03. Industrial Silencer. 04. SMF Batteries with leads as per the Manufacturer standards

-

-

-

... More
(c) AMF PANEL: Cubical, Compartmentalized, AMF Panel Baord with all Power & Control Contractors,for both main & dg along with battery charger,relay,timer & all required accessories, Meters and other accessories, Internal Wiring, connection, inter-connection etc. for Trouble Free smooth function for 500KVA DG Set complete with Battery Charger & leads as required. (d) BASE PLATE: Common Base Plate of required size for mounting of Engine Alternator Set fabricated from MS Channerl and vibration damping arrangement with cushy foor mounting including paintng etc. as required. (e) FOUNDATION: Suitable size Cement Concrete (1:2:4) foundation duly plastered and finished with neat coat Cement as required along with smoke exhaust system piping including base frame of structure & lightening protection system. *It also includes 2 nos copper plate earthing and 4 nos copper plate earthing for neutral, control cable of 15mtr 2.5sqmm 6core , civil foundation work. (The Manufacturing of DG set shall not in any case be more than six months old from the date of award of work)

1

-

-

... More
Lightning Protection :-

-

-

-

... More
Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/Equeivalent

524

-

-

... More
Supply of Roof conductor holder for parapet- Polyamide Conductor holder:With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/Equeivalent

250

-

-

... More
Supply of Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance. Tested as per IEC 62561. Make-OBO/Dehn/Equeivalent

30

-

-

... More
Supply of Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Tested as per IEC 62561.(2nos/expansion piece ).Make-OBO/Dehn/Equeivalent

18

-

-

... More
Supply of 1 mtr vertical air terminal with mounting accessories on the flat surface to meet the requirements of IS/IEC 62305. Tested for Electrical , mechanical and chemical as per IEC 62561. Tested for 100kA lightning current. Make-OBO/Dehn/Equeivalent

18

-

-

... More
Supply of Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3 Nominal size Ø10/16 mm aluminium rod: 2 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. Tested as per IEC 62561. Make-OBO/Dehn/Equeivalent

10

-

-

... More
Supply for Providing of Stand for Fang Fix system 16 kg with base and clamp ,made up of frost resistant concrete and clamp tested upto 100KA lightning current . Make-OBO/Dehn/Equeivalent

20

-

-

... More
Supply for Providing of Stand for Fang Fix system 16 kg made up of frost resistant concrete. Make-OBO/Dehn/Equeivalent

20

-

-

... More
Supply of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Engineer. Tested for 100kA lightning current. Make-OBO/Dehn/Equeivalent

10

-

-

... More
Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr Height For Test Joint .Internal dimensions: 100x100x48 mm Make-OBO/Dehn/Equeivalent

10

-

-

... More
Supply of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized. Tested as per IEC 62561. Make-OBO/Dehn/Equeivalent

140

-

-

... More
Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. Make-OBO/Dehn/Equeivalent

14

-

-

... More
Supply of flat conductor holder- Fit: FL 30, With mounting hole 6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from hot-dip galvanised steel, Bottom section from polyamide, black. Tested as per IEC 62561. Make-OBO/Dehn/Equeivalent

14

-

-

... More
Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. Make-OBO/Dehn/Equeivalent

2

-

-

... More
Supply of UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 17.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2 Make-OBO/Dehn/Equeivalent

10

-

-

... More
Supply of universal clamp made of SS to connect rod with flat conductor Make-OBO/Dehn/Equeivalent

10

-

-

... More
Supply of Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested Make-OBO/Dehn/Equeivalent

10

-

-

... More
Supply of The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system. Make-OBO/Dehn/Equeivalent

10

-

-

... More
Installation of The above arrangements including all accessories as per Direction of Engg. In charge.

1

-

-

... More
LIGHT SYSTEM

-

-

-

... More
S/F of Street light- 90W,120 lm/w efficacy ,IP PC Lens new generation energy saving & environmental friendly long life versatile pressure die-cast alluminium IP66 roadway luminaire with high power LED as light source with acrylic cover(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) (5Years Warranty)

16

-

-

... More
Supply of 6 mtr long hot dip Galvanized Octagonal pole manufactured from HT steel as per BS EN 10025/IS 2062 having minimum yield strength of 350 N/ SQMM having top dia of 70 MM A/F and bottom dia of 130 MM A/F of 3 mm thick or more , base plate as per IS 2062 complete with 4 nos. En 8 grade foundation bolts to withstand basic wind speed of 180 KM/HR wind speed (As per structural calculation of pole manufacturer )or more (Make of poles: Utkarsh/Bajaj/RR Ispat as per direction of Engg. in Charge.

12

-

-

... More
Installation of pole by making the suitable size foundation by embeding the pole 1 mtr into the ground with necessary civil work and fixing the light on the pole equievalant make ISI marked as approved as per direction of Engg. in Charge.

12

-

-

... More
Supplying, Erection, Fixing, connection & testing of LED BOUNDRY WALL Light of elegant look (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) 35 W LED street light having die cast aluminium housing with toughened glass having lumen efficacy of 110 lm/w or more (As per LM 79 report of third party NABL lab) ,IP 65 protection or more , LED street light model having warrantied for a period of 5 years . The luminaire should be supplied along with bracket maintenance free for inspection as required as per direction of Engg.-in-Charge.

12

-

-

... More
Supplying, Erection, Fixing, connection & testing of 40W LED GATE Light of (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) maintenance free having 2 years warranty G.I P ipe with braket including MCB box & including with foundation as per the Drawing for inspection as required & as per direction of Engg.-in-Charge.

2

-

-

... More
Supplying ,installation & fixing of 10-11W(BOLLARD), High efficient LED with extruded Aluminium housing with PC diffuser.CRI70, IP65, CCT - 6500K, Ambient temp-0 to 45DegC, Driver efficiency80%,THD25%, Powerfactor0.9, Surge protection-4 kV, Multistage Isolated Constant Current-Constant Voltage driver and Safety Extra Low Voltage Safe level60V DC as per IEC standard. Luminaire efficacy ≥ (90 lm/W). Make-Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) including with foundation as per the Drawing for inspection as required & as per direction of Engg.-in-Charge.

12

-

-

... More
Supply ,Installation testing commissioning of Asthetically designed 40-45W(post top), High efficient LED comprises with spun aluminium top cover ,dicast aluminium heatsink,frosted polycarbonate diffuser with dicast mounting base arm.CRI70, IP65, Ambient temp-0 to 45DegC, Driver efficiency85%, CCT-4000/5700K,THD10%,Powerfactor0.95, Surge protection-4 kV internal and 10KV external, Multistage Isolated Constant Current-Constant Voltage operated driver with range 150-300V AC and Safety Extra Low Voltage Safe level60V DC as per IEC standard. Luminaire lumen ≥ 4600 lumens (115 lm/W). Similar to Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)l make having warrantied for a period of 5 years . The luminaire to be installed in 6 mtr long GI hot dip galvanized pole with anti corroson,,uv rays stabilized,metal post with covered by resin of Valmount/BAJAJ/RR ISPAT/UTKASH make equievalant make with proper model complete with SA bracket internal JB with 4 way connector and MCB as per the pole drawing and direction of EIC against which inspection mat take place. It should be installed after making proper size RCC foundation by considering RCC foundation by using M20 grade RCC & Fe 415 grade reinforcement and fixing the 4 nos. En 8 grade J type fdn bolts in the foundation. The luminaire needs to be wired with 3 c 1 sq mm wire from JB as per the direction of Engg-in -charge.

10

-

-

... More
SITC of IP 65 Non-integral flexible LED strip light in 5 mtr length with 12W/Mtr power consuption available with wide beam angle 120 degree is equipped with separate energy efficient isolated electronic driver for safe operation., 3000K with 12 w/mtr @ 5Mtr pool with Driver extra,all required accessories with laying base as required as per direction of Engg.-in-Charge ( MakePanasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 5 years

4

-

-

... More
Supplying, Erection, Fixing, connection & testing of 100W FLOOD Light(120LM/W) of Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) maintenance free having 2 years warranty wit including MCB,stainless steel braket along with driver & including with foundation as per the Drawing for inspection as required & as per direction of Engg.-in-Charge.

4

-

-

... More
S/IT/C of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.The entire earthing system should be Replacement Warranty will be 2 years

4

-

-

... More
Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge.

244

-

-

... More
CABLING

-

-

-

... More
Supplying of one number PVC insulated armoured and PVC sheathed XLPE AL. conductor power cable of 1.1 KV grade POLYCAB/ HAVELLS / RR KABEL/ FINOLEX/ GLOSTER of following size cables as per direction of Engg.-in-Charge.Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials

-

-

-

... More
3.5core x 35 sq mm

100

-

-

... More
4core x 16 sq mm

100

-

-

... More
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.

100

-

-

... More
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 120 SQ. MM From 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge.

100

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge.

-

-

-

... More
3.5 core x35sq mm

4

-

-

... More
4core x 16 sq mm

4

-

-

... More
Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover of reputed make,ISI marked with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials

300

-

-

... More
Providing,fixing and laying of fallowing dia PN10 HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge.

-

-

-

160

-

-

... More
S/I/T&Commissioning of LT OUT DOOR FLOOR mounted cubical type IP66 based panel made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing. (FOR USE) with 32A TPN MCB 01 NO,1 no. Astronomical digital timer, AUTO MANUAL(with start and stop push button) SELECTOR 32 A 3P contactor, OLR,RYB,ON,OFF trip indication, Type-II SPD 40ka ,,04 nos 10A 4P MCB,C,10KA as outgoing Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period 3 years of acceptance of materials

2

-

-

... More
UPS SYSTEM

-

-

-

... More
Supply ,installation ,testing & commissioning of 80KVA Parallel UPS SYSTEM WITH IGBT based inverter system, true online double conversion system, inbuilt isolation transformer & automatic phase sequence corrector of 3ph in put to 3 ph output,415V, with built in BMS with battery back up up to 30 minutes with MS Rack for battery Housing, DC cable 7 Mtr with SFU and links for installation (Battery required: 12V, 100AH, 60 No.s) protection for fault by OL,UV,EF,GF,OC,Ph. (Make:Numeric/APC/ Vertiv/) LOAD OF OT,ICU) as per direction of Engg.-in-Charge. Warranty period of all accessories & component & system must be 2 years & complete test certificate must be submitted along with ups including component list & SLD.

1

-

-

... More
ON GRID SOLAR SOLAR PV SYSTEM

-

-

-

... More
Supply Installation Testing and Commissioning of on grid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono / Poly Crystalline silicon solar cells, net metering facility ,necessary protections, earthing, mounted on Aluminium / GI structure of suitable strength with following components a complete aas arequired: a) Solar Photovoltaic Module of capacity 330Wp or above, manufactured in India, conforming to IS14286 / IEC61215, IS/IEC61730-Part-1,IS/IEC61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants /systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase , 4 wire, 50Hz +/- 2.5Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree Celcious. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage,frequency. c) Data Monitoring System complete with accessories.d)Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugsand other accessories etc. asarequired.e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/ conduit lugs and other accessories etc. asrequired. with all required accessories as required as per the direction of Engg-in-charge.Make-Kamal Solar/ EMMVEE/ Venus / Anchor/panasonic or equievalant reputed make & model A catogory, ISI marked as approved . The entire SOLAR system should be Replacement Warranty will be 5 years

15

-

-

... More
HVAC(VRF/VRV)

-

-

-

... More
Inverter based VRV/ VRF System

-

-

-

... More
Outdoor Units

-

-

-

... More
Supply,Installation, Testing and Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling only, having all hermetically sealed inverter type Scroll/Twin rotary Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. The unit shall deliver the rated capacity at AHRI Conditions and work even at 49°C ambient temperature without tripping. The unit shall be suitable to work on 380-415 V, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. MS/GI powder coated stand with vibration isolation pads. The ODU shall have low noise condenser fans with external static pressure of the outdoor unit shall be more then 75 Pa to avoid hot air recirculation, auto address setting, automatic refrigerant charging,auto check function for connection error and complete with indoor and outdoor units with individual controller and with fittings etc. .The Unit should have free phase technology so that unit can work in case of phase reversal also without tripping of units.(Make: MITSUBISHI ELECTRIC /DAIKIN/O-General/Hitachi sigma model )

-

-

-

... More
12 HP(For Dialysis,KMC,Opthalmology OT,OT-1,OT-2,Maternity OT)

6

-

-

... More
14 HP (for Cassette & Hi-wall)

1

-

-

... More
16 HP(SNCU-1)

1

-

-

... More
10 HP(SNCU)

1

-

-

... More
20 HP (For Cassette & Hi-wall)

21

-

-

... More
S/I/T/C of ODU Connecting Kit

22

-

-

... More
Supply, Installation,Testing and Commissioning of following minimu capacity 4-way/ VRV Cassette Type Indoor ceiling mounted unit equipped with cord less remote , synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, drain pan, drain pump, cassette grill, insulation, necessary supports, vibration isolation etc, suitable for operation on 230 V ± 10%, 50 Hz single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire. All indoor Units should have force shut option to connect with fire alarm adaptor, so that the unit automatically stops in case or fire. The cooling capacity of indoor unit will be at air inlet conditions of 27 degree C DBT and 19 degree C WBT. .

-

-

-

... More
1.05 TR

35

-

-

... More
1.20 TR

14

-

-

... More
1.5 TR

36

-

-

... More
2.0 TR

22

-

-

... More
2.5 TR

23

-

-

40

-

-

... More
4.0 TR

7

-

-

... More
Supply,installation,Testing & commissioning of Y joints to connect various indoor unit to outdoor unit

186

-

-

... More
Supply,Installation,Testing & commissioning of centralised I-Touch Manager indoor units. This should be Touch screen type with necessary adaptors .(Make: MITSUBISHI ELECTRIC /DAIKIN/O-General/Hitachi sigma model )

1

-

-

... More
Supply, Installation,Testing and Commissioning of following minimum cpacity Wall Mounted Type Indoor unit equipped with cord less remote , synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, insulation, necessary supports, vibration isolation etc, suitable for operation on 230 V ± 10%, 50 Hz single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire. All indoor Units should have force shut option to connect with fire alarm adaptor, so that the unit automatically stops in case or fire. The cooling capacity of indoor unit will be at air inlet conditions of 27 degree C DBT and 19 degree C WBT. (Make: MITSUBISHI ELECTRIC /DAIKIN/O-General/Hitachi sigma model )

-

-

-

... More
2.06 TR

2

-

-

... More
2.5 TR

2

-

-

... More
AHU For OT

-

-

-

... More
AIR HANDLING UNIT - 2 Stage Filtration- with VFD -Supply, Installation, testing and commissioning of factory fabricated double skin type Air Handling Units (BMS compatible) Floor Mounted Units with fire dampers for High Precision Zones as per specifications given below:-AHU Construction:- It shall be made out of min.0.6 mm pre-plasticized/pre-coated Galvanised steel sheet outside & 0.6 mm plain stainless steel sheet inside with 50 mm thick PUF insulation factory injected between them by injection moulding m/c, with density not less than 38 kg/Cum between them. Drain pan (made out of 1.25 mm stainless steel (SS Grade 304) sheet insulated with 19 mm think closed cell insulation(Nitrile/XLPE) & thermal break profile. Necessary foundation required & anti vibration pads shall be provided & cost for the same shall be included in this item. Supply Air Stream:- 1) Filter section consisting of pre filter and microvee/fine filter . Pre-filter section shall be with non woven synthetic media of 10 micron particle size with an efficiency of 90%, fine/microvee filter section will be with filters of non woven synthetic media of 3 micron particle size of efficiency 99%.2) BACKWARD CURVED PLUG/Centrifugal fans (with min. 70% efficiency) with blower motor, drive and flexible duct connection. The supply fan shall be provided with variable frequency drive and input / output signal compatible to BMS system.3) 6 row deep cooling coil 4) No Heating Coil Required 5) 50 mm Thick Puf Panel with Inner and outer Sheet of .6 mm thick both Side 6) Mixing Box comprising of damper & filter section.COIL- Copper tubes and Aluminium fins 12-13 fin./inch, Coil size shall be selected for air velocity of 500 ft/minute 12deg Celcius coil leaving temp & velocity across filters at 500 ft/minute. 7) 4.5 kW Heater bank.Motors shall be suitable for 415 ± 10% volts, 50 Hz, 3 phase AC supply & high efficiency(IE 3). Vibration isolation shall be as per specifications and as shown on the drawings. VFD:- VFD designed for HVAC applications with built-in PID controller, control panel (keypad & display) , IP-54 enclosure for use on standard BACKWARD CURVED PLUG/Centrifugal fans. The display should be in alpha-numeric characters and programming facility should be in user-friendly HVAC terminology. IP 20 Rated VFD to be placed inside the Stater Panel with IP 55 enclosure. Each VFD panel to be provided with digital display showing electrical parameters like voltage,current and power consumption.Sound level 72 db at the distance of 2 mtr.(maximum)Squirrel cage induction motors suitable for 415 ± 10% volts, 50 Hz, AC supply & high efficiency (IE-3 Efficiency), H.P of motor and coil shall be as per actual selection meeting other technical requirements. At the time of odering ahu total pressure loss as per friction method and ahu coil selection should be submitted for approval. Room design temp-19 deg celcius/RH-55%,INTAKE AIR DBT/RH-19 Deg. Cel./55%, Discharge air DBT/RH-12/96%. if any increase in head, no additional cost will be paid by the agency.4000 CFM / 17TR/6 RD CC / 110 mm TSP with Pre & Fine Filter - (Make:- VTS/ Trane/Systemair/Edgetech) For Major OTs

1

-

-

... More
AIR HANDLING UNIT - 2 Stage Filtration- with VFD -Supply, Installation, testing and commissioning of factory fabricated double skin type Air Handling Units (BMS compatible) Ceiling Mounted Units with fire dampers for High Precision Zones as per specifications given below:-AHU Construction:- It shall be made out of min.0.6 mm pre-plasticized/pre-coated Galvanised steel sheet outside & 0.6 mm plain stainless steel sheet inside with 50 mm thick PUF insulation factory injected between them by injection moulding m/c, with density not less than 38 kg/Cum between them. Drain pan (made out of 1.25 mm stainless steel (SS Grade 304) sheet insulated with 19 mm think closed cell insulation(Nitrile/XLPE) & thermal break profile. Necessary foundation required & anti vibration pads shall be provided & cost for the same shall be included in this item. Supply Air Stream:- 1) Filter section consisting of pre filter and microvee/fine filter . Pre-filter section shall be with non woven synthetic media of 10 micron particle size with an efficiency of 90%, fine/microvee filter section will be with filters of non woven synthetic media of 3 micron particle size of efficiency 99%.2) BACKWARD CURVED PLUG/Centrifugal fans (with min. 70% efficiency) with blower motor, drive and flexible duct connection. The supply fan shall be provided with variable frequency drive and input / output signal compatible to BMS system.3) 6 row deep cooling coil 4) No Heating Coil Required 5) 50 mm Thick Puf Panel with Inner and outer Sheet of .6 mm thick both Side 6) Mixing Box comprising of damper & filter section.COIL- Copper tubes and Aluminium fins 12-13 fin./inch, Coil size shall be selected for air velocity of 500 ft/minute 12deg Celcius coil leaving temp & velocity across filters at 500 ft/minute. Motors shall be suitable for 415 ± 10% volts, 50 Hz, 3 phase AC supply & high efficiency(IE 3). Vibration isolation shall be as per specifications and as shown on the drawings. VFD:- VFD designed for HVAC applications with built-in PID controller, control panel (keypad & display) , IP-54 enclosure for use on standard BACKWARD CURVED PLUG/Centrifugal fans. The display should be in alpha-numeric characters and programming facility should be in user-friendly HVAC terminology. IP 20 Rated VFD to be placed inside the Stater Panel with IP 55 enclosure. Each VFD panel to be provided with digital display showing electrical parameters like voltage,current and power consumption.Sound level 72 db at the distance of 2 mtr.(maximum)Squirrel cage induction motors suitable for 415 ± 10% volts, 50 Hz, AC supply & high efficiency (IE-3 Efficiency), H.P of motor and coil shall be as per actual selection meeting other technical requirements. At the time of odering ahu total pressure loss as per friction method and ahu coil selection should be submitted for approval.Room design temp-24 deg celcius/RH-55%,INTAKE AIR DBT/RH-24 Deg. Cel./55%, Discharge air DBT/RH-12/96%. if any increase in head, no additional cost will be paid by the agency.The ceiling suspended unit should be placed outside the SNCU AND DIALYSIS UNIT. 75 mm TSP with Pre & Fine Filter - (Make:- VTS/ Trane/Edgetech/Systemair)

-

-

-

... More
Capacity -12 TR 4500 CFM /75mm SP/6RD.(SNCU-1)

2

-

-

... More
Capacity -10 TR 4000 CFM /75mm SP/6RD.(KMC&Dialysis )

2

-

-

... More
SITC of 2 hr fire rated smoke exhaust fan of 2500CFM 75 mm Static Pressure (For SNCU).Make-Krugger/Nicotra/Systemaire

1

-

-

... More
SITC of exhaust fan 400CFM 15 mm Static Pressure (For Injection Room, Dead body Room, Plaster Room, Dressing Room)Make-Krugger/Nicotra/Systemaire

5

-

-

... More
Refrigerant Piping

-

-

-

... More
Supply & Installation of interconnecting following sizes of refrigerant copper pipe work of following outer diameter, insulated with 25mm thick closed cell electrometric Nitrile rubber tubular insulation between each set of indoor & outdoor units . The pipe dia upto 25 shall be soft seamless & above 25mm dia shall be hard seamless . All piping inside the room shall be properly fixed/supported with suitable size of clamp/ M.S. hanger and all external piping shall run in GI. cable tray etc. as reqd. Make of insulation-K Flex/Armacell/A-Flex Make of pipe-Rajco/Mandev

-

-

-

... More
41.3 mm

224

-

-

... More
34.9 mm

212

-

-

... More
28.6 mm

215

-

-

... More
22.2 mm

215

-

-

... More
19.1 mm

240

-

-

... More
12.7 mm

254

-

-

... More
15.9 mm

252

-

-

... More
9.5 mm

265

-

-

... More
6.4 mm

210

-

-

... More
Drain Piping

-

-

-

... More
Providing & fixing of PVC Pipe complete with fittings, supports as per specifications and duly insulated with 9 mm thickness Class O of closed cell nitrile rubber/XLPE as per direction of Engineer-in-charge & specifications enclosed as reqd.

-

-

-

... More
50 mm dia

266

-

-

... More
40 MM dia

266

-

-

... More
32 mm dia

380

-

-

... More
Control & Transmission Wiring

-

-

-

... More
Providing & fixing control cum transmission wiring of 2 core x 1.0 sqmm shielded copper cable in suitable conduits between indoor and out door unit. Make-Polycab/ Finolex/ RR Kabel/ Gloster

1450

-

-

... More
Gas Charging for the entire circuit(R410A)

175

-

-

... More
Air Distribution (OT)

-

-

-

... More
Supply, Manufacturing, fixing,testing and commisioning of Alluminium ducting complete with supports,dampers etc.as per specifications. MakeTATA/SAIL/JINDAL

-

-

-

... More
22 Gauge Al.sheet.

260

-

-

... More
24 Gauge Al.sheet.

412

-

-

... More
Insulation work

-

-

-

... More
Supply,installation,testing and commissioning of duct thermal insulation of Following Capacities , Make - Armacell/A flex/K flex . - with 25 mm thick Nitrile Rubber for indoor supply air ducting

412

-

-

... More
Accoustic Insulation 15 mm thick of Armasound open cell nitrile rubber

260

-

-

... More
Flexible canvas connection

16

-

-

... More
Supply, erection, testing & commissioning of Aluminium powder coated grilles with VCD having flange all around.Make-Glenstorm/Airflow/Systemaire

6

-

-

... More
Supply, erection, testing & commissioning of Aluminium powder coated grilles without VCD having flange all around.Make-Glenstorm/Airflow/Systemaire

6

-

-

... More
FIRE FIGHTING

-

-

-

... More
PUMPS AND APPURTENANCES

-

-

-

... More
Supply , installation, testing & commissioning of Motor driven end suction Back pullout type Centrifugal pump delivering 2280 LPM at 70 Mtr head with CI casing bronze impeller and SS shaft with mechanical seal (for Wet riser & Sprinkler system) with 2 pole TEFC motor suitable for operation on 415 V ,3 ph, 50 C/s AC supply and complying to TAC norms including providing base frame coupling,coupling guard as per direction of Engineer-in-charge (Make:PUMP:KBL/ Grundfos / KSB/ Wilo)

1

-

-

... More
Supply , installation, testing & commissioning of Diesel Engine driven end suction Back pullout type Centrifugal pump having 2280 LPM at 70 Mtr head with CI casing bronze impeller and SS shaft with mechanical seal and suitable diesel engine complying to TAC norms along with all accessories including control wiring between panel & DG set and fuel storage tank including providing base frame coupling,coupling guard as per direction of Engineer-in-charge..(Make:PUMP:KBL/ Grundfos / KSB/Wilo)

1

-

-

... More
Supply , installation, testing & commissioning of Motor driven end suction Back pullout type Centrifugal Jocky pump delivering 180 LPM at 70Mtr head with CI casing bronze impeller , SS shaft with mechanical seal and 2 pole TEFC electric motor suitable for operation on 415 V ,3 ph, 50 C/s AC supply including providing base frame coupling,coupling guaaard as per direction of Engineer-in-charge..(Make:Kirlosker/ Gunfoss / KSB/ wilo)

1

-

-

... More
Supplying, installation, testing and commissioning of Electric Motor Driven Pressurization Terrace Pump having discharge of 450 LPM at 35 MWC head complete with Pump Set, Electric Motor suitable for operation on 415 V ,3 ph, 50 c/s AC supply , Base Frame , 2 no. pressure switch, 1 no. pressure gauges, 2 nos. Butterfly valves, 1 no. NRV as required

1

-

-

... More
S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by Red out & inside gray powder cote paint is designed as G.A drawing. (FOR FIRE FIGHTING) BUILDING POWER)as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 3 years & compelete test certificate must be submitted along with panel board including component list.Type 2 SPD shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed. INCOMING: One(1)- 400 Amp 36 KA TP with solid neutral SDFU with HRC fuses 3 nos (Make-HPL/L&T/Siemens/Schneider) including 01 no of MFM with RS 485, 3 Nos 400/5 metering CTs of Class 1.0, ON/ OFF indicating lamps, 3 Nos Phase indicating lamp and SP 6A MCB ( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9). . Busbar- 04 numbers of 500Amps 50kA Electrolytic copper busbar duly sleeved by color coaded PVC sleeve & supported by suitable size DMC insulator. OUTGOING: a)One(1)-250 Amp 36kA TP MCCB with ROM 36kA with adjustable MICRO PROCESSOR Release with Ics=100% Icu. ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS), along with star delta starter incorporating 3 nos Power 3P contactor with top add on(2NO+2NC) ,Bimetal OLR of suitable rating,axulary contactor , ON/ OFF push button, ON/ OFF indicating lamp, 3 Nos CTs metering CTs 250/5, Ammeter . b) 1 No (Outgoing) – 63 Amp 36kA TP MCCB with ROM 36kA with adjustable MICRO PROCESSOR Release with Ics=100% Icu. ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS), along with star delta starter suitable for motor with O/L release, ON/ OFF push button, ON/ OFF indicating lamp,3nos 50/5 CT,Ammeter,S/S c) 1 Set – Relay, Auto/ Manual Selector Switch, Battery Charger, Annunciation Panel,hotor, Control wiring of pressure switches, flow switches and starters etc as required for auto and manual operation of Jockey pumps, Main Electric Pumps and Diesel Engine Pump as per direction of Engineer-in-charge.d)1 lot control wiring from pressure switch to panel board through auxiliary contactor with 1.5 sq. mm unarmoured PVC insulated ,PVC sheathed copper cable etc as required.

-

-

-

... More
PANEL AS ABOVE

1

-

-

... More
Supply, installation, testing and commissioning of Floor/Wall mounted sectionalised, front operated top entry dust and vermin proof M.V.Panel Boards suitable for operation at 415V, 3 phase, 4 wire, 50Hz distribution system fabricated out of 2.0 mm thick CRCA sheet, insulated busbar with heat shrinkable PVC sleeve, base frame, complete with all accessories including interconnections, earth bus etc as required comprising of. One (1)- 63 Amp, 10 KA,TPN (Class-C) MCB with 3 Nos Phase indicating lamps with control fuse/ MCB, Digital Voltmeter with selector switch. DOL starter with O/L and Single Phasing Preventor suitable for motor. ON/OFF indication lamps, Auto manual switch and ON/OFF push button.

-

-

-

... More
One (1) - Set of Auxilliary relay for automatic operation through pressure switch.

-

-

-

... More
PANEL AS ABOVE

1

-

-

... More
Supply & Laying of XLPE power cable of 1.1 KV grade of following size on Cable

-

-

-

... More
3C X 70 sqmm

88

-

-

... More
3C X 16 sqmm

100

-

-

... More
Cable tray

-

-

-

... More
Supplying instalaltion hot dip galvanized ladder type cable tray of following size including installation along wall/ suspended from ceiling with brackets/ threaded suspenders including bends etc as required.

-

-

-

... More
150 mm (W) X 50 mm (H) with 1.2 mm thick sheet

100

-

-

... More
450 mm (W) X 50 mm (H) with 1.6 mm thick sheet

88

-

-

... More
Cable laying

-

-

-

... More
Laying & fixing of one no. PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size on Cable Tray as required.

-

-

-

... More
Upto 35 Sqmm

80

-

-

... More
Above 35 Sqmm and upto 95 sqmm

86

-

-

... More
End Termination

-

-

-

... More
Supply & Making end Termination with brass compression gland and aluminium lugs for PVC insulated and PVC sheathed cable of 1.1 kv grade (without cost of Cable)

-

-

-

... More
3C X 70 sqmm

4

-

-

... More
3C X 16 sqmm

4

-

-

... More
PIPE & VALVES ETC.

-

-

-

... More
Supply,Installation,Testing & Commissioning of 'C' Class heavy duty MS pipe (as per IS 1239 upto 150 mm NB and IS 3589 for above 150 mm 6.33mm thick) with flanges and fitting such as bends, tees, reducers, rubber insertions and galvanized nuts and bolts of following size on surface along wall / shaft with MS bracket, suspended from ceiling/ beam with suspenders duly painted with two coats of primer and finished with enamel paint of approved colour laid through pipe or in trench after wrapping with hassen cloth after applying coal tar primer as required as per direction of Engineer-in- charge.Make-TATA/JINDAL/SAIL

-

-

-

... More
200mm NB

20

-

-

... More
150mm NB

188

-

-

... More
100mm NB

188

-

-

... More
80mm NB

32

-

-

... More
65mm NB

750

-

-

... More
50mm NB

120

-

-

... More
40mm NB

88

-

-

... More
32mm NB

311

-

-

... More
25mm NB

444

-

-

... More
Supply,Testing & Commissioning of 'C' Class heavy duty MS pipe (as per IS 1239 upto 150 mm NB and IS 3589 for above 150 mm 6mm thick) with flanges and fitting such as bends, tees, reducers, rubber insertions and galvanized nuts and bolts of following size including laying in ground after excavation and refilling of trench along with providing 4mm thick pipecoat for underground pipe after applying wrapping coating primer as required as per direction of Engineer-in- charge.Make-TATA/JINDAL/SAIL

-

-

-

... More
150mm NB

98

-

-

... More
Providing, fixing, testing and commissioning of following size manually operated hand lever type cast iron double flanged slim seal wafer type Butterfly valves with EPDM iron disc as per IS-13095 having pressure ratting PN -1.60 including fixing the same with supply of required jointing materials like rubber insertion, MS nuts & bolts, paint etc. and testing the joints with required water pressure etc. all complete as per specification & direction of E.I.C.Make-Zoloto/Kartar/Kirloskar/Leader

-

-

-

... More
150mm NB

5

-

-

... More
100mm NB

4

-

-

... More
80mm NB

2

-

-

... More
SITC of CI Gate valves as per IS:14846 and rising sprindle type with flanges, bolts, nuts, washers , gaskets, etc.Make-Zoloto/Kartar/Kirloskar/Leader

-

-

-

... More
200mm NB

2

-

-

... More
Providing, fitting & fixing of following size cast iron double flanged type dual plate Non return Valve as per IS- 5312 (Part 1): 2004 with ISI mark of pressure ratting PN-1.60 including fixing the same with supply of required jointing materials like flanges, rubber insertion, MS nuts & bolts, paint etc. and testing the joints with required water pressure etc. all complete as per specification & direction of Engineer-in-charge. Make-Zoloto/Kartar/Kirloskar/Leader

-

-

-

... More
150mm NB

5

-

-

... More
100mm NB

4

-

-

... More
Supply,Installation,Testing & Commissioning of Pressure gauge of 0-16 Kgf/sq.cm. range with cut-off bronze ball valves of suitable size with all accessories as per direction of Engineer-in-charge.Make-H.Guru/G.Guru

4

-

-

... More
Supply,Installation,Testing & Commissioning of Pressure Switch with cut-off bronze ball valves with integral strainer & flare nut (mixed ends) of suitable size with all accessories as per direction of Engineer-in-charge.Make-Danfoss/Grundfoss/Indfoss

4

-

-

... More
Supply,Installation,Testing & Commissioning of stainless steel strainer fabricated out of 1.6 mm thick stainless steel sheet Y Stainer with 3 mm dia hloes with stainless steel flange as required. Make-Zoloto/Kartar/Kirloskar/Leader

-

-

-

... More
150mm NB

2

-

-

... More
100mm NB

2

-

-

... More
Supply,Installation,Testing & Commissioning of Air vessel made of 250mm dia, 8mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia Gun metal wheel valve, with required accessories, pressure gauge and painting with synthetic enamel paint as required.

1

-

-

... More
WET RISER CUM DOWN COMER SYSTEM

-

-

-

... More
Supply,Installation,Testing & Commissioning of Stainless steel Hydrant Valve / Landing valve, of 63 mm NB size, type-A, single headed , oblique type, as per IS :5290/93 and as per direction of Engineer-in-charge.Make-Minimax/Newage/Fireshield/Safex

30

-

-

... More
Supply,Installation,Testing & Commissioning of SS short branch pipe with 63 mm male inlet and 19 mm outlet nozzle, as per IS:903 and as per direction of Engineer-in-charge.Make-Minimax/Newage/Fireshield/Safex

30

-

-

... More
Supply,Installation,Testing & Commissioning of 63 mm NB and 15meter long RRL Fire Hose fitted with 63mm intstantaneous stainless steel male & female SS coupling, complete by GI wire binding for Internal Hydrant as per direction of Engineer-in-charge.Make-Minimax/Newage/Fireshield/Safex

60

-

-

... More
Providing supply & fixing of MS Hose Box for of suitable size(750X600X250mm) to accomodate 2 nos. of 15/ 1 no of 30 mtr long fire hose and a branch pipe, wall mounted type as per direction of Engineer-in-charge.Make-Minimax/Newage/Fireshield/Safex

30

-

-

... More
Supply,Installation,Testing & Commissioning of Swinging pattern wall fixing first aid hose reel made from MS sheet and waterways and moving parts with rubber hose of 20 mm dia. and 30 mtrs. long with ABS(Plastic) shut-off nozzle as per IS: 444/IS: 12585 Type-I., complete with all accessories as per direction of Engineer-in-charge.Make-Minimax/Newage/Fireshield/Safex

30

-

-

... More
Providing, fitting and fixing of C.I. 25 MM single air relief valve with stop cock confirming to IS:14845/2000 with ISI mark for water works purpose including fixing the same with hydrant riser including testing & commissioning the system etc. all complete as per approved specification & direction of Engineer-in-charge.

6

-

-

... More
Providing, fitting & fixing of 4-Way GM fire brigade connection consisting of 63 mm dia instantaneous type male couplings with built-in check valves, 150mm dia flanged outlet complete with bolts, nuts and rubber insertions confirming to IS:904 with ISI mark including testing & commissioning the system etc. all complete as per apporoved specification & direction of EIC. Make-Zoloto/Karatr/Kirloskar

2

-

-

... More
SPRINKLER SYSTEM

-

-

-

... More
Supply,Installation,Testing & Commissioning of Pendent/ Upright type Standrd Sprinkler with QB of 68 /79 deg. C temperature rating and 1/2" end connection confirming to IS: 15105 with ISI mark for all floors etc. all complete as per direction of Engineer-in-charge. Make-Tyco/HD/Viaking

1422

-

-

... More
Supply,Installation,Testing & Commissioning of Cast Iron Ball Valve with teflon seals, Stainless steel Ball & Stem, MS Lever with PVC Coating As Per IS: 9890 ISI Marked. Make-Tyco/HD/Viaking

24

-

-

... More
Providing, fitting and fixing of C.I. single Air relief valve with stop cock confirming to IS:14845/2000 with ISI mark for water works purpose including fixing the same with hydrant riser including testing & commissioning the system etc. all complete as per approved specification & direction of EIC. Make-Tyco/HD/Viaking

4

-

-

... More
Providing & fixing of 25 mm size Gunmetal Pressure Release Valve with isolation valve and all accessories conforming to IS3233:1965 as per direction of Engineer-in-charge. Make-Tyco/HD/Viaking

4

-

-

... More
Providing, laying, testing & commissioning of Flexible Sprinkler Hose Corrugated Unbraided type of length 1mtr for Fire Sprinklers, with 1'' Inlet Nipple BSPT,1/2" Outlet Reducer BSPT,0.7 m Square Supports Bar & Brackets(UL Listed) with all complete accessories as per direction of Engineer-in-charge. Make-Tyco/HD/Viaking

1422

-

-

... More
Providing and fixing of electric flow switch with mechanical time delay feature capable of sensing a minimum of flow of one sprinkler , including making electrical cable termination through input module & integrated with Fire Alarm System.Make-Honeywell/eq.

10

-

-

... More
Supplying, installing, testing and commissioning of hydralically operated Sprinkler control valve (150mm)complete with water motor gong bell, basic trims as required, pressure gauges, pressure switch, drain valves, ball valves etc. complete. Alarm valve shall be UL Listed / FM approved.Make-system sensor/siemens

1

-

-

... More
EXTINGUISHER SYSTEM

-

-

-

... More
Portable Fire Extinguisher System Supplying, installation, testing and commissioning of CO2 type Fire Extinguisher 4.5 kg capacity confirming to IS: 2878 made from ISI marked seamless cylinder confirming to IS: 7285, fitted with ISI marked controlled valve confirming to IS: 3224, high pressure 1mtr discharge hose & horn complete with initial gas charged with carrying handle & wall mounting bracket as per direction of Engineer-in-charge. Make-Safex/Fireshield/Ceasefire

30

-

-

... More
Supplying, installation, testing and commissioning of ABC type fire extinguishers of 6 kg capacity including cost of all material & labour etc complete. Make-Safex/Fireshield/Ceasefire

30

-

-

... More
Fire buckets (FILLED WITH SAND) round bottom type enamel painted, white inside & Red out side and Letter "FIRE" in black out side and handle with mounting bracket.

2

-

-

... More
AUTOMATIC FIRE ALARMING SYSTEM

-

-

-

... More
Supply, Installation,Testing & Commisioning of Microprocessor based Addresable fire alarm control panel , fully networkable with each loop capable of taking 99 devices, 8 line x 40 character alpha- numeric liquid crystal display .The panel shall be soft addressable type . The panel shall be able to give pin point location of all fire/fault conditions. Further, the panel must be able to automatically switch off respective control switches when ever any alarm is triggered. The panel shall have integral SMF lead acid batteries with sealed cells of 24 V capable of running for a minimum of 8 hours with integral battery charger complete as required and as per specification. The fire alarm panel shall be suitable for software integration with BMS & PA system.Make-Morley IAS/Siemens/Bosch/Edward

2

-

-

... More
4 Loop

-

-

-

... More
Supply, Installation, Testing & commissioning of Analog Addressable smoke cum heat detector withinbuilt isolator module and status indicator . Make-Morley IAS/Siemens/Bosch/Edward

1400

-

-

... More
Supply, Installation, Testing & commissioning of Addressable Manual Call Point soft addressable type with in built fault isolator as required.Make-Morley IAS/Siemens/Bosch/Edward

40

-

-

... More
Supply, Installation, Testing & commissioning ofAddressable Loop Powered Hooter cum Strobe (sound output of minimum 90db) cum strobe (strength of light 10cd) complete with inbuilt isolator as required. Make-Morley IAS/Siemens/Bosch/Edward

40

-

-

... More
Supply & Fixing of 2 core 1.5 sq.mm, multi strand, copper conductor, FRLS (Fire Retardent Low Smoke)-PVC insulated GI Screened Armoured cable with saddle and required accessories.& Power Cable. Make-Polycab/RR cable/finolex/havells

5000

-

-

... More
PA SYSTEM

-

-

-

... More
Supplying, installation, testing & commissioning of 6 zone,voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required .Make. Honeywell/Bose/Bosch

1

-

-

... More
Supplying, installation, testing & commissioning of digital audio amplifier 1000 Watt, 25V rms operating at 240 Volt AC Supply complete as required. Make. Honeywell/ Bose/ Bosch

1

-

-

... More
Supplying, installation, testing & commissioning of ceiling/wall mounted loud speaker, 3/15 Watt in ABS enclosure complete as required Make. Honeywell/Bose/Bosch

60

-

-

... More
Supplying and drawing of speaker cable Single pair, 2-core, 1.5 sqmm in existing conduits.

2155

-

-

... More
SIGNAGES

-

-

-

... More
SIGNAGES:-Providing and installing in position the following type of sign boards made out of 3mm thick flexyle photoluminescent based glow in dark sheeting with luminous properties enclosed in a weather proof Uvstabilized film with UV screen printing by imported links pasted over3 mm thick cast acrylic from front side with 6 mm thick acrylic, -20 to+80 deg C, Suitablefor indoor use, greenish yellow, glow visible upto 4-6 hr in total darkness.Make-Prolite/Bajaj or Equivalent

4600

-

-

... More
Illumination Glow light for Exit Indication with Battery Back-up.Make-Prolite/Bajaj or Equivalent

14

-

-

... More
S/F of evacuation plan- outer cover 3 mm thick photolluminiscent plastic, paint highest quality UV resistant glass paint frame Aluminium made material non-radioactive, non phosphorous, non-toxic and laed free , glowing time ≥ 3000 mins luminance 215mcd/sqm warranty 5 years as the direction of Eng-in-charge(A1) size on steel frame with cc work.

1

-

-

... More
S/F of evacuation plan- outer cover 3 mm thick photolluminiscent plastic, paint highest quality UV resistant glass paint frame Aluminium made material non-radioactive, non phosphorous, non-toxic and laed free , glowing time ≥ 3000 mins luminance 215mcd/sqm warranty 5 years as the direction of Eng-in-charge(A3) size on steel frame with cc work.

10

-

-

... More
FIRE SUPPRESSION SYSTEM

-

-

-

... More
Supply , Installattion,Testing and Comissioning of 5LB Clean Agent System Complete with all Necessary Clean Agent FK-5-1512 /novec 1230 (UL listed )gas with PESO approved cvlinder fitting support and accessories,connected with CE,PI Mark & PESO approved DLP valve,End of line Adaptor and pressure switch Cylinder will be Helium Leak Tested to 10-7 mbar I/S for leakage proof Make:SUPREMEX/FIREBOY/AMEREX

1

-

-

... More
Supply and Laying of Linear Pneumatic Heat Detection Tube with all Necessary Fittings & Supports.

50

-

-

... More
Supply , Installattion,Testing and Comissioning of Health Monitoring Panel with Audio Visual Alarm. The Panel Should Have Provision for Integration with Fire Alarm/SCADA/BMS System. Make:SUPREMEX/FIREBOY/AMEREX

1

-

-

... More
Supply and Laying UPVC Pipe (80 schedule ) of Following Dia-Meter Burried in Ground at Appropriate Depth for Cable

55

-

-

... More
Subhead- 1 (Lan System)

-

-

-

... More
Supply & Laying of Cat6 23Awg UTP Cable, through existing conduit, Make: Legrand/Systimax/Panduit

14500

-

-

... More
Supply & fixing of RJ-45Jack of Category 6 with Dual-port British-style Face plate 86x86 mm with Curveture and wall mount box Make: Legrand/Systimax/Panduit

90

-

-

... More
Supply & fixing of Cat6 24 Port Jack Panel loaded with individual keystone:Make: Legrand/Systimax/Panduit

22

-

-

... More
Supply & Installation of Cat6 Factory crimpped moulded patch cord,1mtr, Make: Legrand/Systimax/Panduit

510

-

-

... More
Supply & Installation of Cat6 Factory crimpped moulded patch cord, 2mtr. Make: Legrand/Systimax/Panduit

36

-

-

... More
Supply & Installation of 6F Single Mode Armoured FO Cable through existing conduit. Make: Legrand/Systimax/Panduit

4255

-

-

... More
Supply, Installation,Testing & Commisioning of 24 Port Rack Mount Loaded LIU including SM SC Adaptor and Pigtail. Make: Legrand/Systimax/Panduit

1

-

-

... More
Supply, Installation,Testing & Commisioning of 6Port Rack Mount Loaded LIU including SM SC Adaptor and Pigtail. Make: Legrand/Systimax/Panduit

22

-

-

... More
Supply, Installation,Testing & Commisioning of Single Mode SC-LC Type OFC Patch Cord, 2mtr length.Make: Legrand/Systimax/Panduit

24

-

-

... More
Supply & Installation of 1000Base LX Fiber Transceiver. Make: Cisco/Digisol/HP

24

-

-

... More
Supply and installation of 24 Port Layer2 Giga (10/100/1000BaseT) PoE Switch with 4 x 1Gig SFP Port , Switching Capacity 56 Gbps, Throughput 41.7 Mpps ,Management Port 1 x RJ 45 Console port ,PoE power budget 270 Watt, Switch should support IEEE 802.3af & IEEE 802.3at standard ,MAC Address 16K , Jumbo Frame 12K ,Temperature Working 0°C~50°C, storage -40°C~70°C, Power Supply AC: 100~240VAC.Digisol Model No. DG-GS1528HPE-P/Cisco/HP

22

-

-

... More
Supply and installation of 19" Rack mountable cloud managed Internet Gateway having user configurable LAN/WAN ports 8 x 10/100/1000 Mbps BaseT Ports with 2 x 1Gbps SFP Ports supporting minimum 9 WAN Ethernet Interface. The Gateway should minimum support simultaneously internet user of 1000 clients. Should minimum support 2.5 Gbps Internet Bandwidth. The Gateway should support L3 Routing features like Static, RIPng, OSPFv3. Gateway Level customised Web/URL filtering with L7 Deep Packet Inspection and real time application and user level access control involving access, denial, monitoring, logging and reporting at gateway level.Make-HP/Juniper/Cisco/Ruijie

1

-

-

... More
Supply and installation of 24 Port Gigabit Fiber Ethernet Access Layer 3 Switch with 16 100/1000Base-XSFP + 8GE Combo(RJ45/SFP)+4 10 Gigabit SFP+ Uplink Ports, Switching Capacity 128Gbps, Throughput 95 Mpps ,CPU ARM7 800M , Packet Buffer Memory 1.5 MB ,MAC Address 16K , ACL Table 1K ,Jumbo frame 10k ,Switch should support IEEE802.3(10Base-T), IEEE802.3u(100Base-TX), IEEE802.3z(1000BASE-X), IEEE802.3ab(1000Base-T), IEEE802.3ae(10GBase), IEEE802.3x, IEEE802.3ak(10GBASE-CX4) ,Switch should support Static Routing, RIPv1/v2, OSPFv2,BGP4,OSPFv3, BGP4+Temperature Working 0°C~50°C, storage -40°C~75°C, Power Supply AC: 100~240VAC, 50~60Hz + 12VDC RPS. Digisol(Model No. DG-GS4628SE2)/Cisco/HP/Juniper

1

-

-

... More
Supply & Installation of 9U/500Wall Mount Rack with FAN, PDU, Cable manager and H/W Pkt. Make : Valrack/Rittal/APW

22

-

-

... More
Supply & fixing of 24U 600/650D UL Listed Floor mount Rack loaded with one no 10Skt 5/15A power distribution unit, 4nos cable manager, Four nos 90CFM FANs, 1no HD Self and one pkt H/W screw. Make : Valrack/Rittal/APW

2

-

-

... More
Subhead- 2 (IP-CCTV System)

-

-

-

... More
Supply, Installation, Testing & Commissioning of Full High Definition 5MP( 2880 x 1624) resolution vandal proof dome/bullet camera, 1/3" Progressive Scan CMOS Sensor, IR Cut mechanical Filter for True Day & Night vision, Support dual streams, Onvif supported, IP66 Weather proof outdoor enclosure, Inbuilt Smart IR LEDs with intensity control, IR 30 mtr, H.264 / H.265, Supports android and iOS APP for Smart phone and tablets, with Inbuilt audio, -10°C to + 50°C, CE, FCC, RoHS .  Make-Honeywell series 20/Pelco/Axis

188

-

-

... More
Supply, Installation,Testing & Commisioning of 64 Chanel 4K H.265 Pro NVR with support 8*SATA HDD.Make: Honeywell series 20/Pelco/Axis

3

-

-

... More
Supply, Installation,Testing & Commisioning of Surveliance 8 TB HDDMake:- WD/Segate/Toshiba

24

-

-

... More
Supply & installation of 55'' IPS Ultra HD AI for 24x7 application TV.Make:LG/Samsung/Sony

4

-

-

... More
P.H. WORK Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge

-

-

-

... More
20mm dia C - PVC pipe

-

-

-

... More
Ground Floor

60

-

-

... More
First Floor

70

-

-

... More
Second Floor

50

-

-

... More
Third Floor

50

-

-

... More
Fourth Floor

50

-

-

... More
25mm dia C - PVC pipe

-

-

-

... More
Ground Floor

80

-

-

... More
First Floor

90

-

-

... More
Second Floor

60

-

-

... More
Third Floor

60

-

-

... More
Fourth Floor

60

-

-

... More
32mm dia C - PVC pipe Top Floor

250

-

-

... More
40mm dia C - PVC pipe Top Floor

200

-

-

... More
50mm dia C - PVC pipe Top Floor

180

-

-

... More
Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials including cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.

-

-

-

... More
15mm dia CP angle stop cock (Con-CHR-053KN Jaquar make)

299

-

-

... More
15mm dia CP two in one bib cock (Con-CHR-041KN Jaquar make)

94

-

-

... More
15 mm dia CP S.B. Bib cock(CON-CHR-037KN)

22

-

-

... More
15mm dia CP Long Body Bib cock (Con-CHR-107KN Jaquar make)

58

-

-

... More
20mm dia CP consealed stop cock(Con-CHR-083KN Jaquar make)

29

-

-

... More
15mm dia CP Pillar cock (Con-CHR-011KN Jaquar make)

148

-

-

... More
25mm dia brass full way valve (Shakti make)

20

-

-

... More
32mm dia brass full way valve (Shakti make)

20

-

-

... More
40mm dia brass full way valve (Shakti make)

10

-

-

... More
50mm dia brass full way valve (Shakti make)

10

-

-

... More
15mm dia CP Health faucet (Con-ALD-MCH-573 Jaquar make)

94

-

-

... More
WALL MIXER WITH PROVISION FOR OVERHEAD Shower (FLR-ABR-5273UPR)

10

-

-

... More
15mm CP Extension piece

650

-

-

... More
125mm CP grating

310

-

-

... More
15mm size C.P. flange

650

-

-

... More
2 nos Construction of 20000 Liters RCC Over head Tank of Inside size- 6.00 X 3.00 X1.50m roof of roof of 4th floor

-

-

-

... More
Supplying all materials, labour, T&P and providing cement concrete (1:1:5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge

33.52

-

-

... More
Supplying all materials, labour, T&P and providing M.S.Reinforcement for RCC work including cutting, banding, binding, straightening and trying the grills and placing in position including cost of binding wire 18 to 20 gage.

33.52

-

-

... More
Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for RCC work including false work and dismantling then after casting including cost of materials complete in ground floor.

-

-

-

... More
RCC floor roof, chajja etc

92.5

-

-

... More
RCC Beam, Column, wall etc

184.9

-

-

... More
Supplying all materials, labour,T&P and providing 6mm thick cement plasster (1:4) over CC work including watering curring and conveyance of all materials to site.

104.4

-

-

... More
Supplying all materials, labour, T&P and providing cement punning including watering, curring and conveyance of all materials to site.

-

-

-

... More
Quantity same as item No-4

104.4

-

-

... More
Providing fitting and fixing stainless steel ladder including fixing to wall necessary welding etc. complete

120

-

-

... More
Providing fitting and fixing MS cover made out of MS angle and sheet duly welding and fixing with frame and hinges along with locking arrangement of size 60cmx60cm etc complete as per direction of Engineer-in-charge

80

-

-

... More
supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings including watering, curing, cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per direction of Engineer-in-charge.

-

-

-

... More
Ground Floor

49

-

-

... More
First Floor

58

-

-

... More
Second Floor

43

-

-

... More
Third Floor

47

-

-

... More
Fourth Floor

41

-

-

... More
Supplying all materials , labour, T&P and cutting holes in RCC floors and roofs upto 19cm thick for passing P.V.C pipes and G.I fittings etc. , and repairing the holes after insertion of pipe etc. with cement concrete (1:2:4) including finishing complete so as to make it leak-proof as per P.H. specification and direction of Engineer-in-charge

-

-

-

... More
Ground Floor

25

-

-

... More
First Floor

29

-

-

... More
Second Floor

22

-

-

... More
Third Floor

24

-

-

... More
Fourth Floor

21

-

-

... More
Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages including watering , curing , cost & conveyance of all materials to worksite, payment of royality, taxes etc all complete as per direction of the Engineer-in-charge.

-

-

-

... More
Ground Floor

70

-

-

... More
First Floor

80

-

-

... More
Second Floor

60

-

-

... More
Third Floor

60

-

-

... More
Fourth Floor

60

-

-

... More
Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.

-

-

-

... More
110mm U-PVC SWR Pipe (Supreme /Ashirvad)

1800

-

-

... More
110mm U-PVC ‘P’ Trap(Ori Plast/Finolex/Supreme Make)

300

-

-

... More
110mm U-PVC door bend(Ori Plast/Finolex/Supreme Make)

250

-

-

... More
110mm U-PVC Plain bend(Ori Plast/Finolex/Supreme Make)

250

-

-

... More
110mm U-PVC offset without ear(Ori Plast/Finolex/Supreme Make)

130

-

-

... More
110mm U-PVC Cowl(Ori Plast/Finolex/Supreme Make)

14

-

-

... More
110mm U-PVC S/Jn door(Ori Plast/Finolex/Supreme Make)

200

-

-

... More
110mm U-PVC Plain tee(Ori Plast/Finolex/Supreme Make)

400

-

-

... More
110mm U-PVC D/Jn door(Ori Plast/Finolex/Supreme Make)

130

-

-

... More
110mm U-PVC Door tee(Ori Plast/Finolex/Supreme Make)

220

-

-

... More
110mm U-PVC Socket(Ori Plast/Finolex/Supreme Make)

400

-

-

... More
Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x30mm footrest, fixing 100mm dia HCI 'p' or 's' trap (with/without 50mm dia horn) for water colset squatting pan including jointing the trap with pan in cement mortar (1:1) cutting the floor and mending good the damages , cost & conveyance of all materials to worksite, payment of royality , taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.

-

-

-

... More
580mm size Orissa pan (Hindware/Parryware/Neycer make)

22

-

-

... More
Supplying all materials, labour T&P and and fixing 12.50 liters/10 liters capacity low level flushing cistern with a pair of cast iron or M.S. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle,unions and couplings for connection with inlet, outlet and overflow pipes, 32mm dia CP long flush bend, 15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connceting the inlet pipe with suupply main , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge

-

-

-

... More
10 ltr. Capacity pvc L.L. cistern with 32mm. Dia CP long flush bend ( Slimline-white-Parryware make )

95

-

-

... More
Supplying all materials,labour,T&P and fixing Flat back lipped wall (Mini stall urinal -630mmx180mm) urinal of the following sizes including connecting the urinal with 32mm. dia pvc waste pipe 910mm. long by means of white lead mixed with chopped hemp, fixing 32mm. dia CP dome waste, 15mm. dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc. all complete as per specification and direction of the Engineer in charge Half stall urinal

36

-

-

... More
Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet(European type W.C. pan)with integral 'p' or 's' trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1) fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing , cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge

-

-

-

... More
European water closet with 'p' trap plain(Hindware/Parryware/Neycer make)

73

-

-

... More
One piece commod(Hindware)ELEMENT Cat No.92084.

20

-

-

... More
Matrix set of Hindware

1

-

-

... More
Supplying all materials, labour T&P and fixing wash basins with hole for pillar taps with cast iron or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered 'Hot' and 'Cold' with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, cost & conveyance of all materials to worksite, payment of taxes etc. all complete as perP.H specification and direction of the Engineer-in-charge

-

-

-

... More
Under Counter basin(560x450)Hindware-No.10095

68

-

-

... More
Halfpedestal basin(560x450)Hindware No.91049+91115

58

-

-

... More
Supplying all materials, labour, T&P for fitting & fixing plain edge kitchen/wall sink of all standard sizes with a pair of bracket, C.P. waste, trap & P.V.C. waste pipe & painting brackets including supply of cement concrete & mortar etc. all complete. 24” x 18” x 10” sink

22

-

-

... More
Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge

-

-

-

... More
25mmx600mm long CP towel rail

36

-

-

... More
Towel ring

148

-

-

... More
Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rail complete fixed to wooden plugs with CP screws as per specification and direction of Engineer in charge.

-

-

-

... More
600mmx125mm plate glass shelf with CP/NP guard rails.

58

-

-

... More
Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm.thick A.C. sheet or ply wood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of Engineer in charge.

-

-

-

... More
Large Size mirror with Frame (68x0.90x0.75)=

45.9

-

-

... More
600mmx450mm size B.E mirror (swivelled type)

58

-

-

... More
Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge

-

-

-

... More
CP soap holder

148

-

-

... More
Supplying all materials labor T&P & Fitting & fixing CP shower with rim with supply of red lead and yarn nail complete as per direction of Engineer in charge.

-

-

-

... More
½” x 5” CP Shower (Plaza Deluxe Make)

29

-

-

... More
Supplying all materials , labour, T&P and cutting holes through existing brick or laterite masonry wall for taking U-PVC pipes and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge

300

-

-

... More
Supplying all materials , labour, T&P and cutting of RCC chajja for taking HCI or U-PVC pipe and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge

150

-

-

... More
Supplying all materials ,labour ,T&P and constructing Inspection Chamber of inside size 760mmx760mmx460mm with cement concrete (1:3:6) using 40mm size crusher broken hard black granite metal on bed , KB brick work in cement mortar (1:6) in foundation and plinth, moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips, 12mm thick cement plaster (1:3) with cement punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab (1:2:4) using 12mm size crusher broken hard black granite chips with R.C.C man hole cover, earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc.all complete as per approved drawing, P.H specification and direction of Engineer-in-charge

-

-

-

... More
Inside size 76cmx76cmx46cm with 18” dia RCC MH cover

14

-

-

... More
Supplying all materials ,labour ,T&P and constructing gully trap chamber of inside size 250mmx250mm with 8cm thick RCC precast cover slab in cement concrete (1:2:4) mix using 12mm size crusher broken HG chips, foundation concrete (1:4:8) using 40mm size crusher broken HG metal on bed and around trap, KB brick work in cement mortar (1:6) in foundation and plinth and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap, 150mmX150mm size CI grating etc.all complete as per drawing, specification and direction of Engineer-in-charge

14

-

-

... More
Supplying all materials labour T&P filling sand in lavatories well watered and rammed including lead of materials to work site.

18.91

-

-

... More
Supplying all materials, labour, T&P and providing cement concrete ( 1:4:8 ) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge

12.61

-

-

... More
Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge

-

-

-

... More
Ground Floor

12.61

-

-

... More
First Floor

11.62

-

-

... More
Second Floor

12.06

-

-

... More
Third Floor

15.68

-

-

... More
Fourth Floor

11.26

-

-

... More
Providing & applying water proofing treatment (Two Component glass fibre reinforced specially formulated acrylic modified, cementitious elastic coating system) using Sika Top Seal 109 hi & Sika Fab-1 or equivalent (glass fibre cloth) @ 3Kg/Sq.mtr before one coat of Sika Top Seal 109 hi or equivalent Primer @ 200 gm/Sq.mtr over the cleaned RCC Horizontal Surface & Outer retaining wall etc including the cost of all materials, cost of labour, conveyance, taxes, T&P, etc. all complete as per the direction of Engineer-in-Charge.

-

-

-

... More
First Floor

184.23

-

-

... More
Second Floor

122.51

-

-

... More
Third Floor

156.29

-

-

... More
Fourth Floor

109.84

-

-

... More
Supplying all materials, labour, T&P and providing and fixing ceramic tiles in floors, treads or steps and landing on 25mm thick bed of cement mortar (1:1) ( 1 cement : 1 sand ) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge ( ceramic floor tiles of premium grade having thickness 7mm to 8mm conforming to IS 13755 of size Kajaria/Somany/Johnson tile 60cmx60cm special printed series to be pre-approved by the Engineer-in-charge )

-

-

-

... More
Kajaria/Somany/Johnson tile 60cmx60cm

-

-

-

... More
Ground Floor

126.08

-

-

... More
First Floor

116.23

-

-

... More
Second Floor

120.59

-

-

... More
Third Floor

156.8

-

-

... More
Forth Floor

112.58

-

-

... More
Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:4) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge.

-

-

-

... More
Ground Floor

376.82

-

-

... More
First Floor

467.63

-

-

... More
Second Floor

368.34

-

-

... More
Third Floor

517.23

-

-

... More
Fourth Floor

359.56

-

-

... More
Supplying all materials, labour, T&P and providing and fixing porcelain glazed tiles in dado skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge( ceramic wall tiles of premium grade having thickness 6.5mm to 6.7mm conforming to IS 13753 of size Kajaria/Somany/Johnson tile 60cmx30cm special plain / printed series to be pre-approved by the Engineer-in-charge )

-

-

-

... More
Kajaria/Somany/Johnson tile 60cmx30cm

-

-

-

... More
Ground Floor

376.82

-

-

... More
First Floor

467.63

-

-

... More
Second Floor

368.34

-

-

... More
Third Floor

517.27

-

-

... More
Forth Floor

359.56

-

-

... More
Granite Tiles 10mm Thick For W.H.B.

-

-

-

... More
Ground Floor

6.38

-

-

... More
First Floor

5.47

-

-

... More
Second Floor

6.38

-

-

... More
Third Floor

7.3

-

-

... More
Fourth Floor

5.47

-

-

... More
Granite Tiles 10mm Thick For Urinal

-

-

-

... More
Ground Floor

5.4

-

-

... More
First Floor

5.4

-

-

... More
Second Floor

8.1

-

-

... More
Third Floor

5.4

-

-

... More
Fourth Floor

8.1

-

-

... More
Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 650kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter. of make Rajshri Plastiwood/ Alstone/Aramstrong or euivalant as per direction of Engineer-in-charge.

246.06

-

-

... More
Factory made Solid WPC door frame of size 90mmx45mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification. of make Rajshri Plastiwood/ Alstone/ Aramstrong or euivalant as per direction of Engineer-in-charge.

763.04

-

-

... More
Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) pure chill 80 PSS UV of size 750 x 570 x 1350mm hight with water storage capacity 80 liter's along with 2 noa of faucets 1 for cold water and 1 for normal water including a flow of 1.5 ltr per munite etc all complete as per approved drawing , specification and direction of the Engineer in charge

-

-

-

... More
Aqua guard pure Chill 80 PSS UV

10

-

-

... More
Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized P.V.C. pipe conforming to IS 4985/2000 of the following out side dia for class- 3 (0.60mpa ) including jointing with supply of approved solvent cement by non-heat application method/as per manufacture's specification, provoding and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per P.H. specification and direction of the Engineer in charge

-

-

-

... More
100mm dia P.V.C. pipe

140

-

-

... More
150mm dia P.V.C. pipe

220

-

-

... More
Supplying all materials labor T&P and constructing MH chamber of sizes earth work in excavation in all kinds of soil CC(1:1:8) with black granite chips size 46mm brick work with K.B. brick having crossing strength not less than 75 Kg /CM2 to 90 Kg/CM2s in CM(1:6)12mm C.P(1:8) inside MH chamber over benching with cement slush pointing (1:3)outside the MH chamber providing painting MS or CI step iron RCC(roof of slab with CC(1:2:4)with black granite chips size 12mm bending binding tying the grills placing of the reinforcement providing RCC color of required size refilling the cavity around the MH chamber with excavated earth including channeling the bed of MH etc all complete as per PH specification.

-

-

-

... More
MH size 0.91m x 0.91 m with 0.45 m (18” dia RCC Cover )

20

-

-

... More
Supplying all materials labour T&P and constructing 1.80m dia x 2.60 m deep soak way pit with dry brick having crossing strength not less than 75Kg/CM2 to 99Kg/CM2 in CM(1:6) for the remaining 0.4572mm height of wall at top CC(1:3)inside and outside inside fill with dry brick khoa size 38mm ,CM thick RCC perforated slab to a height of 1.9012m from bottom covered by means of 50mmthick RCC wall cover in pieces filled with iron plugs including earth work in excavation refilling of cavity around the pit and painting the iron works complete as per PHD design and specification including carriage of all materials to site.

4

-

-

... More
Construction 2 nos 200 users RCC Septic tank

-

-

-

... More
Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-Charge.

214.28

-

-

... More
Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge with 1st extra lift of 1.50 m over initial laft.

142.38

-

-

... More
Supplying all materials,labour ,T&P and filling in foundation and plinth with sand well watered and rammed including cost, conveyance of all materials to work site ,payment of royalty,taxes etc. all complete as per direction of the Engineer-in -charge

22.94

-

-

... More
Supplying all materials, labour, T&P and providing cement concrete ( 1:4:8 ) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge.

18.08

-

-

... More
Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge

8

-

-

... More
Supplying all materials, labour, T&P and providing cement concrete (1:1:5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge

87.34

-

-

... More
Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge

-

-

-

... More
RCC floor roof, chajja etc

90.36

-

-

... More
RCC Beam, Column, wall etc

265.4

-

-

... More
RCC Plinth bend/ Raft

-

-

-

... More
Base slab

30.42

-

-

... More
Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge

87.34

-

-

... More
Supplying all materials,labour,T&P and providing 6mm thick cement plaster(1:4) on RCC work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge.

151.86

-

-

... More
Supplying all materials,labour,T&P and providing 12mm CP (1:4) with cement punning on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge.

16.2

-

-

... More
Supplying all materials, labour, T&P and providing,fitting and fixing 150mm x 150mm x 100mm SW Tee in wall including filling the recess with cement concrete (1:3:6) with 12mm size h.g chips all complete including watering, curing, conveyance of all materials to worksite, payment of royalty all complete as per specification and direction of the Engineer in charge

4

-

-

... More
Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge.

24

-

-

... More
Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge

117.7

-

-

... More
Construction of 150000 Liters RCC Under ground Reserver of Inside size- 12.00 X 6.50 X2.30m

-

-

-

... More
Earth work in All kinds of soil and gravels mixed with stone and boulder not exceeding 0.014 Cum in volume within 50m initiallead and 1.5 m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per specification approved by the Department.

171.81

-

-

... More
-do- with Ist additional depth of 1.50 m over the initial lead and lift

148.9

-

-

... More
Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer in charge.

30.49

-

-

... More
Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge

20.33

-

-

... More
Supplying all materials, labour, T&P and providing cement concrete (1:1:5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge

80.14

-

-

... More
Supplying all materials, labour, T&P and providing M.S.Reinforcement for RCC work including cutting, banding, binding, straightening and trying the grills and placing in position including cost of binding wire 18 to 20 gage.

-

-

-

... More
@ 100 kg / cum =

80.14

-

-

... More
Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for RCC work including false work and dismantling then after casting including cost of materials complete in ground floor.

-

-

-

... More
RCC floor roof, chajja etc

85.88

-

-

... More
RCC Beam, Column, wall etc

215.37

-

-

... More
RCC Plinth bend/ Raft

-

-

-

... More
Base slab

33.44

-

-

... More
Supplying all materials, labour,T&P and providing 6mm thick cement plasster (1:4) over CC work including watering curring and conveyance of all materials to site.

208.4

-

-

... More
Supplying all materials, labour, T&P and providing cement punning including watering, curring and conveyance of all materials to site.

-

-

-

... More
Quantity same as item No-4

208.4

-

-

... More
Providing fitting and fixing stainless steel ladder including fixing to wall necessary welding etc. complete

120

-

-

... More
Providing fitting and fixing RCPC cover etc complete as per direction of Engineer-in-charge

2

-

-

... More
Shoring and shuttering

-

-

-

... More
Sides

86.68

-

-

... More
De-watering

-

-

-

... More
10 daysx 4hours x 5.0 HP pump

200

-

-

... More
RAIN WATER HARVESTING SYSTEM(PIT)(2 nos)

-

-

-

... More
Earth work in hard soil or gravelly soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-Charge.

66.68

-

-

... More
Supplying all materials, labour, T&P and providing cement concrete (1:4:8) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge

1.08

-

-

... More
Supplying all materials, labour, T&P and providing brick work with Fly ash bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:6) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge

10.14

-

-

... More
Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork with cement punning and bitumen painting over top of wall including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge

91.2

-

-

... More
Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge

48.6

-

-

... More
Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge

-

-

-

... More
R.C.C floor and roof slabs, landings, balconies, projecting sunshades and

3.12

-

-

... More
Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge

-

-

-

... More
In ground floor

0.34

-

-

... More
Supplying all materials, labour, T&P and providing cement concrete (1:1½:3)with 12mm size hard broken granite chips including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge

-

-

-

... More
In ground floorSlab

0.42

-

-

... More
providing and filling filter media

-

-

-

... More
40mm Boulder-

12.74

-

-

... More
20mm washed gravel--

6

-

-

... More
Course sand-

4.5

-

-

... More
Providing fitting & fixing M.S.grill cover over the harvesty pindi

3.1

-

-

... More
Sinking of tube well(200) for PIT

-

-

-

... More
Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/ P.V.C/ M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore only

-

-

-

... More
Drilling of 200mm dia bore

-

-

-

... More
00 mtr to 25mtr

50

-

-

... More
Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials.

-

-

-

... More
200mm dia PVC pipe

50

-

-

... More
cost of 200mm pvc pipe

50

-

-

... More
Cutting slot in casing pipe for recharge of rain water

50

-

-

... More
labour for packing gravel outside the tube well

4.7

-

-

... More
Cost of washed gravel

4.7

-

-

... More
Construction of 2nos production wells including scientific source finding through consolidated and unconsolidated rock with down the hammer drilling rig or combination rig with PVC pipe and installation of submersible pump set with all acessories

-

-

-

... More
Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/ P.V.C/ M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore only

-

-

-

... More
Drilling of 200mm dia bore

-

-

-

... More
00 mtr to 30mtr

60

-

-

... More
30 mtr to 45mtr

30

-

-

... More
Drilling of 150mm dia bore

-

-

-

... More
45 mtr to 215.00mtr

340

-

-

... More
Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials.

-

-

-

... More
Lowering of 200mm dia P.V.C casing pipes

-

-

-

... More
00 mtr to 30 mtrs

60

-

-

... More
30 mtr to 60mtr

30

-

-

... More
Supplying polyvinyl chloride pipes as per ASTM-D-1785-89 having threads in accordance with DIN 2999 part-1/DIN-42225 part-II specification length of pipe (laying length) will be 3 mtrs. The pipes shall be supplied with both external and threaded with free socket. The pipe having external thread at one end i.e female and or belled end. The female end having internal thread is to be belled in order to accept the male end while jointing pipes with a bore threading shall be provided with a greave at the roof of the male thread accomodate flexible PVC/Rubber 'O' ring to make the joint water tight colour of the pipe shall be blue. The name of the manufacture along with batch No class of pipe shall be stranded legibly of each pipe length.

-

-

-

... More
200mm dia PVC (sch-80) pipe

91

-

-

... More
Supplying all materials, labour, T&P and providing and providing sanitary sealing by cement concrete grouting of annular space around GI/PVC/MS housing pipe upto 5m below ground level (as per drawing) to plug the bore hole excluding cost of cement all complete as per direction of the Engineer in charge. Minimum one metre of casing pipe to be inserted in the bore into the rock at the bottom to ensure sanitary sealing (excluding cost of cement which will be supplied directly by the department)

2

-

-

... More
Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge

-

-

-

... More
By DTH Rig

2

-

-

... More
Supplying all materials, equipment, labour & conducting reconnaissance survey, integrated Hydrological and Geophysical (Electrical Resistivity Method) survey & selection of potential source for exploration of Ground Water including selection and recommendation of site for drilling wells in selected locations in any part of Orissa under the following Geological formation:

-

-

-

... More
Rocky terrain with boulder formation for 300m depth

4

-

-

... More
Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge (Texmo/Crompton Greaves/Kirloskar make)

-

-

-

... More
1 H.P. Single phase/ three phase 3 stage head renge of 20 to 35 mtr with discharge capasity 145 to 110 L.P.M With outlet dia 25 mm (keeping 100% standby)

3

-

-

... More
DOL Control panel

3

-

-

... More
40mm dia steel short piece

3

-

-

... More
Well cap

2

-

-

... More
50mm size CI bracket

3

-

-

... More
2.50sqmm flat cable

260

-

-

... More
20mm dia rigid UPVC pipes

90

-

-

... More
Steel rope with cover

90

-

-

... More
Labour charges for lowering including transportation

3

-

-

... More
Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor HDPE pipes and pipe fittings conforming to IS: 4984/2000 (10kgf/sqcm) of the following nominal bore with clamps and jointing by Fusion welding method including testing, making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge

-

-

-

... More
32mm HDPE pipes (Finolex/Supreme make)

260

-

-

... More
Solar Heating System

-

-

-

... More
Supply of Solar flat plate Collectors.of make Supreme Solar/Greentek India/ Radient Energy or equivalant as per direction of Engineer in charge.

32

-

-

... More
Supply of 35Kw 1000LPD/Hr Air Sorce Heat Pump ofmake Thermex/Brio/Neo or equivalant as per direction of Engineer-in-Charge.

1

-

-

... More
Supply of Hot Water insulated pressurized Storage Tank made out of stain less steel SS304grade–2500 ltrs capacity of make Parkland/Radient or equivalant as per direction of Engineer-in-charge.

2

-

-

... More
Supply of NonreturnvalveandSSfittings., 2 nos of Circulation cum pressure pump of make WILO/ GROUNDFOUS with 4 nos Electrical Backup Heater(6KW) internal Kitech pipes and fittings, 40 nos MS power coated Stand for fixing of solar plates etc. as per requirement at siteetc complete as per direction of Engineer-in-charge

1

-

-

... More
Installation of all the above materials on the roof including fitting and fixing of Insulated tank, circulating pump, back-up heater, piping arrangement etc complete with functioning of solar water heating system etc complete as per standard specification and direction of Engineerin-charge

1

-

-

... More
OXYGEN SYSTEM

-

-

-

... More
Fully automatic Oxyaen Controls control panel(flow 1200 lpm)

1

-

-

... More
SITC of fully Automatic pneumatically operated oxyaen control panel. Visual indication ofthe manifold is provided by 3 auaaes within control panel, Indicatina Pressure of the riaht & Left hand bank and the supply pressure from control panel to distribution system with sensina faciliteies to provide visual sianals na other anciliary services such as heaters. Pannel should be fitted with audio alarm indication for chanaeover of empty cylinder. The entire manifold will be hydraulically tested at 130 Ka/Cm2 pressure, duly deareased foroxyaen Service, and supplied in sealed cover, ready for assembly at site etc complete as per direction of Enaineer-in-charae. (Note : Excludina Supply of cylinder.(Make:-United/Unitech/Sharma)

-

-

-

... More
Oxyaen Manifold - 2 banks x 10 cylinders.

1

-

-

... More
SITC of oxyaen manifold of Size (10 workina + 10 Standby) for Indian type bulk cylinders, hiah pressure copper annealed tail pipes complete with middle frame, chains for individual bulk oxyaen cylinder, NRV's and 20 nos. pia tail pipes. it should be suitable to withstand a workina pressure of 145 ka/cm2 and should be tested at 300 ka/cm2. etc complete as per direction of Enaineer-in-charae. (Make:-United/Unitech/Sharma)

-

-

-

... More
Oxyaen Manifold (Emeraency) - 2 banksx 6 cylinder

1

-

-

... More
SITC of oxyaen manifold of Size (6 workina + 6 Standby) for Indian type bulk cylinders, hiah pressure copper annealed tail pipes complete with middle frame, chains for individual bulk oxyaen cylinder, NRV's and 12 nos. pia tail pipes. it should be suitable to withstand a workina pressure of 130 ka/cm2 and should be tested at 300 ka/cm2. etc complete as per direction of Enaineer-in-charae.(Make:- United/Unitech/Sharma)

-

-

-

... More
Gas Outlets with probes - Oxyaen

220

-

-

... More
SITC for Oxyaen Outlets as Per standards, Terminal units shall be capable of sinale-handed insertion and removal of the medical aas probe. The wall mounted first fix assembly shall consist of brass pipeline termination block with copper stub pipe secured between a back plate and a aas specific plate to allow limited radial movement of the copper stub to alian with the pipeline. The aas specific plate shall be permanently fixed to the backplate etc complete as per direction of Enaineer-in-charae(Make:- United/Unitech/Sharma)

-

-

-

... More
Oxyen Flow meters

330

-

-

... More
SITC for Oxyaen flowmeter complete with humidifier bottle, The flow meter must be constructed with chromium plated brass body, extremely robust, to take care of the day to day usaae demand. Flow meter cartridae type knob : easy to maintain, offers optimum adjustment quality and superior desianina and enaineerina to provide hiah level of accuracy, with no sianificant affect from restrictions caused by downstream equipments. The flow meters should be 0-15 LPM ranae for oxyaen. etc complete as per direction of Enaineer-in-charae.(Make:-United/Unitech/Sharma)

-

-

-

... More
NITROUS OXIDE SYSTEM

-

-

-

... More
Fully automatic Nitrous Oxide Controls(500lpm)

1

-

-

... More
SITC for Fully Automatic pneumatically operated N2O control panel. With heater, The entire manifold will be hydraulically tested at 250 Ka/Cm2 pressure, duly deareased , etc complete as per direction of Enaineer-in-charae.(Make:-United/Unitech/Sharma)

-

-

-

... More
N2O Manifold - 2 banks X 3 Cylinder

1

-

-

... More
SITC for (3 working + 3 Standby) size of N2O manifold complete with middle frame, chains, NRV's 6 nos. pig tail pipes, Manifold should have high pressure copper annealed tail pipes with one end having brass bull nose suitable for Nitrous Oxide cylinders and other end suitable for Manifold non- return Valves. Each manifold will have one terminal header and a NPT connection for the Automatic Control Panel. etc complete as per direction of Engineer-in-charge.(Make:-United/ Unitech/ Sharma)

-

-

-

... More
Nitrous oxide manifold - Emergency 2 Banks X 1 Cylinders

1

-

-

... More
SITC for (1 working + 1 Standby) size of N2O manifold complete with middle frame, chains, NRV's 2 nos. pig tail pipes, Manifold should have high pressure copper annealed tail pipes with one end having brass bull nose suitable for Nitrous Oxide cylinders and other end suitable for Manifold non- return Valves. Each manifold will have one terminal header and a NPT connection for the Automatic Control Panel. etc complete as per direction of Engineer-in-charge.(Make:-United/Unitech/Sharma)

-

-

-

... More
Gas Outlets with probes - Nitrous Oxide

12

-

-

... More
SITC for Nitrous Oxide outlets as Per standards, Terminal units shall be capable of single-handed insertion and removal of the medical gas probe. The wall mounted first fix assembly shall consist of brass pipeline termination block with copper stub pipe secured between a back plate and a gas specific plate to allow limited radial movement of the copper stub to align with the pipeline. The gas specific plate shall be permanently fixed to the backplate, etc complete as per direction of Engineer-in-charge.(Make:- United/Unitech/Sharma)

-

-

-

... More
CARBON DIOXIDE SYSTEM

-

-

-

... More
Fully auto CO2 Controls (50lpm)

1

-

-

... More
SITC for Fully Automatic pneumatically operated CO2 control panel. With heater, The entire manifold will be hydraulically tested at 250 Kg/Cm2 pressure, duly degreased , etc complete as per direction of Engineer-in-charge.(Make:-United/Unitech/Sharma)

-

-

-

... More
CO2 Manifold - 2 banks X 2Cylinders

1

-

-

... More
SITC for (2 working + 2 Standby) size of CO2 manifold complete with middle frame, chains, NRV's 4 nos. pig tail pipes, Manifold should have high pressure copper annealed tail pipes with one end having brass bull nose suitable for Carbon dioxide cylinders and other end suitable for Manifold non- return Valves. Each manifold will have one terminal header and a NPT connection for the Automatic Control Panel. etc complete as per direction of Engineer-in-charge.(Make:-United/Aktive Tech./Equal)

-

-

-

... More
CO2 Manifold (Emergency) - 2 banks x 1 cyl

1

-

-

... More
SITC for (1 working + 1 Standby) size of CO2 manifold complete with middle frame, chains, NRV's 2 nos. pig tail pipes, Manifold should have high pressure copper annealed tail pipes with one end having brass bull nose suitable for Carbon dioxide cylinders and other end suitable for Manifold non- return Valves. Each manifold will have one terminal header and a NPT connection for the Automatic Control Panel. etc complete as per direction of Engineer-in-charge.(Make:-United/Unitech/Sharma)

-

-

-

... More
Gas Outlets with probes - CO2

12

-

-

... More
SITC for Carbon diaoxide outlets as Per HTM 2022,Terminal units shall be capable of single-handed insertion and removal of the medical gas probe. The wall mounted first fix assembly shall consist of brass pipeline termination block with copper stub pipe secured between a back plate and a gas specific plate to allow limited radial movement of the copper stub to align with the pipeline. The gas specific plate shall be permanently fixed to the backplate, etc complete as per direction of Engineer-in-charge.(Make:-United/Unitech/Sharma)

-

-

-

... More
VACCUM SYSTEM Make:- EDWARD

1

-

-

... More
SITC of medical vacuum system as per NHS Health Technical memorandum (HTM02-01) & shall ensure minimum pipeline vacuum level of 450mmHg is maintained at the plant service connection point at the rated volumetric ‘free air’ flow rate with two pumps in standby. The bacteria filtration system shall be ‘duplexed’ such that each filter can be isolated for replacement of the filter cartridge No. of Vacuum Pumps- 2 x 10 Hp Oil Lubricated Rotary vane vacuum pumps with Duplex filtration system. Vacuum Receiver’s- 1 x 500Liters or more capacity vertical vacuum receiver. Vacuum receiver(s) shall be supplied with relevant test certificates and have a total volume of at least 100% of the plant output in 1 minute in terms of free air aspired at normal working pressure etc complete as per direction of Engineer-in-charge.

-

-

-

... More
Compressed Air System: 2000 LPM

1

-

-

... More
SITC of Compressed air system complete with oil free air compressor (3 nos. x 57 cfm)15 Hp 9E or similer type air compressors equipped with air receiver capacity of 1000 ltrs. And complete with Air Dryer of 70 cfm. It should be consist of oil-less, stationery air cooled silenced (Reciprocating) air compressor. It should be equipped with three electrical motors, one Air reservoir Tank, Air filters, Pressure Regulator-cum-filter, Air Dryer with moisture separator. Interconnecting pipes with necessary valves and fittings thereof. etc complete as per direction of Engineer-in-charge.(Make:-Anest Iwate)

-

-

-

... More
Gas Outlets with probes - Medical Air ( 4 Bar)

140

-

-

... More
SITC for Compressed M.Air- 4 Bar outlets as Per standards , Terminal units shall be capable of single-handed insertion and removal of the medical gas probe. The wall mounted first fix assembly shall consist of brass pipeline termination block with copper stub pipe secured between a back plate and a gas specific plate to allow limited radial movement of the copper stub to align with the pipeline. The gas specific plate shall be permanently fixed to the backplate, etc complete as per direction of Engineer-in-charge.(Make:-United/Unitech/Sharma)

-

-

-

... More
Gas Outlets with probes - Surgical Air (7 Bar)

15

-

-

... More
SITC for Compressed M.Air- 7 Bar outlets as Per HTM 2022/ NFPA, Terminal units shall be capable of singlehanded insertion and removal of the medical gas probe. The wall mounted first fix assembly shall consist of brass pipeline termination block with copper stub pipe secured between a back plate and a gas specific plate to allow limited radial movement of the copper stub to align with the pipeline. The gas specific plate shall be permanently fixed to the backplate, etc complete as per direction of Engineer-in-charge.(Make:-United/Unitech/Sharma)

-

-

-

... More
Outlets with probes - Vacuum

220

-

-

... More
SITC for Vacuum outlets as per standards, Terminal units shall be capable of single-handed insertion and removal of the medical gas probe. The wall mounted first fix assembly shall consist of brass pipeline termination block with copper stub pipe secured between a back plate and a gas specific plate to allow limited radial movement of the copper stub to align with the pipeline. The gas specific plate shall be permanently fixed to the backplate, etc complete as per direction of Engineer-in-charge.

-

-

-

... More
Ward Vacuum with regulator and jar (600 Ml) .(Make:-United/Unitech/Sharma)

330

-

-

... More
Theater Suction jars with regulator (theatres,2*2000 ml) .(Make:-United/Unitech/Sharma)

10

-

-

... More
Medical grade Copper pipe:

-

-

-

... More
SITC for Medical Grade copper pipe with required copper fittings, All pipes shall be drawn half hard temp., solid drawn, seamless, phosphorous deoxidised, non-arsenic and degreased copper pipe conforming to EN BS: 13348:2008/ASTM B819 standard ,EN 1057:1996 (originally BS 2871-1971 Part 1 (Table X) and chemical composition as per BS-6017 of 1981 table 2, The supplies of copper pipe would be accompanied with manufacturers test certificate for the physical properties of copper pipes and their Chemical composition. The supply of pipes be further substantiated with inspection certificate from the third party like SGS/Lloyds Register. etc complete as per direction of Engineer-in-charge.(MAKE:-Rajco Metals/Janya Extrusion/Mandev tube/Maxflow)

-

-

-

... More
12mm x 0.7 OD

674

-

-

... More
15mm x 0.9 OD

2981

-

-

... More
22mmx 0.9 OD

2040

-

-

... More
28mmx 0.9 OD

1630

-

-

... More
42mmx 1 OD

715

-

-

... More
54mmx1,OD

420

-

-

... More
76mm x1 OD

225

-

-

... More
Copper fittings for copper pipes (MAKE:-Rajco Metals/Janiya Extrusion/Mandev tube)

-

-

-

... More
Zonal Valve Service ( Valves with Box)(Make:-United/Unitech/Sharma)

-

-

-

... More
1gas+1Vac(2 gas )

10

-

-

... More
2gas+1Vac(3gas)

10

-

-

... More
5 gas+1Vac(6 gas)

5

-

-

... More
Isolation Valve service (MAKE:-MATRIX)

-

-

-

... More
12 mm dia

60

-

-

... More
15 mm dia

20

-

-

... More
22 mm dia

20

-

-

... More
28 mm dia

30

-

-

... More
42 mm dia

8

-

-

... More
54 mm dia

6

-

-

... More
76 mm dia

3

-

-

... More
Master Alarm service ( Digital ), post source(Make:-United/Unitech/Sharma)

1

-

-

... More
Area Alarm service ( ANALOG) (Make:- United/Unitech/Sharma)

-

-

-

... More
2 Gas ( 1 O2 + 1 Vac)

10

-

-

... More
3 Gas ( 1 O2 + 1 Vac + 1 MA4)

10

-

-

... More
5 Gas (1 O2 + 1 Vac + 1 N2O + 1 CO2 + 1 SA7)

5

-

-

... More
Antistatic Hose

-

-

-

... More
Hiah Pressure Antistatic Hose

50

-

-

... More
Low pressure Antistatic Hose

200

-

-

... More
Bed Head Panels (Size - 1000 X 300 X 110 mm) (Make:-United/Unitech/Sharma)

-

-

-

... More
SITC for pure extruded aluminium made with powder coat finish, having 5 Nos gas outlets, 2 Nos electric panels havina 4 nos of 6/16 Amp switches and 4 Nos of electrical sockets ( 6/16 Amp) Make - Legrand or similer type, Provision for Nurse call display, SS IV pole with holder and utility basket etc complete as per direction of Engineer-incharge.

116

-

-

... More
Kit conversion for Nitrous Oxide

4

-

-

... More
Kit conversion for Oxygen

4

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.