Public Health Engineering Organisation Tender

... More
The PHEO has issued a formal invitation for competitive bids for the Public Health Engineering Organisation project, for Construction Of Collector Well At Brahmani Head Works And Augmentation Of Distribution System For Zonal W/s System At Dhenkanal (reach-ii). in Cuttack, Odisha, with an estimated contract value of Rs. 6,92,73,000. The bid opening date for this tender is 30-05-2025 and the last date for bid submission is 16-06-2025. Interested bidders for Public Health Engineering Organisation tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Public Health Engineering Organisation - PHEO Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date30 May 2025
Closing Date16 Jun 2025
Tender Amount₹ 6,92,73,000 
Notes
Download

AI Insights

Class Of Bidder
... View More
The eligible classes required by a bidder to participate or bid in the tender are 'A Class' and 'Special Class'.
Bid Capacity
... View More
The formula for bid capacity is: Assessed Available Bid Capacity = (A*N*2-B) Where: A = Maximum value of works executed in any one year during the last five years including GST.
Technical Capacity
... View More
The bidder should have successfully completed work(s) valuing not less than Rs. 207.82 Lakh in any one financial year during the last 5 financial years. The completed work must cover at least one specific type of project, such as a Drinking Water Treatment Plant or Sewage Treatment Plant, among others. Additionally, the bidder should have an annual financial turnover of not less than Rs. 277.10 Lakh in any one financial year in Civil Construction Works during the last 5 financial years. The bidder is required to have prior work experience, specifically in the execution of similar works, and should provide a list of similar works executed during the last 5 years, including details such as the value of the contract price and the total value of work executed. The weightage for pipeline work is 30% and for structural works is 20%. The bidder's available bid capacity will be calculated based on the maximum value of works executed in any one year during the last five years, including GST. The assessed available bid capacity will be calculated using the formula: Assessed Available Bid Capacity = (A*N*2-B), where A is the maximum value of works executed in any one year during the last five years, including GST. The bidder should have good working records of completion of works in time and satisfy the minimum eligible criteria for the award of the contract. The bidder should provide certification from the employer in support of the claim of similar works executed.

Costs

Summary

Construction Of Collector Well At Brahmani Head Works And Augmentation Of Distribution System For Zonal W/s System At Dhenkanal (reach-ii).

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Pressure switch: Pressure switches of the electronic type with either ace manic sensor for low pressures and thin film senor for pressures above 16 bar. Pressure switches and differential pressure switches shall have contacts with differing cut-in' and cut-out' pressure values with NO/NC contact to take signals. The nominal pressure values at which pressure and differential pressure switches operate shall be fully adjustable over the whole range of the instrument and the set value shall be clearly indicated by means of a scale and pointer or LED digital display. Pressure switches shall have over range protection. Pressure switches shall be housed in cast bronze or aluminum alloy enclosures. The degree of protection to BS EN 60529:1992 shall be IP 54 for indoor installation, IP 65 for outdoor installation or IP 68 for locations liable to flooding with a maximum submergence of 20 meters.

1

20000

-

... More
Pressure Gauge-250 mm: Providing, erecting Pressure gauge of required range complete with syphon tube, isolating cock suitable for 12 mm dia G.1. Pipe. Pressure gauge shall be installed as directed, with tapping on rising main

1

7500

-

... More
Float Control valve: Providing and installing the float control valve to regulate the flow/level of water in OGR as per innstruction of EIC.

1

68200

-

... More
Supply, Installation Making foundation, Testing & Commissioning of Silent Type Diesel Generating Set (DG set) with Accoustic enclosure having Engine alternator assembly mounted on AVM with Silencer and S.S exhaust bellow suitably optimized to meet stringent sound emission standards as laid down by MOEF / CPCB Base rall with draw-out type fuel tank is provided with a drain plug, air Vent inlet and outlet connections, level Indicator, manhole etc. Sub-base fuel tank with 13 hours capacity at 75% load ,12 V dry, batteries with connecting leads and terminals, 90% gloss RAL9003 white pure polyester powder coated, base in black colour. Control panel: RAL 9003 white Powder coated control panel manufactured with CRCA sheet provides: MCB of suitable rating with short circuit protection, Controller which displays voltage, current, KW, PF, Frequency, KWh. Indicating lamps for "Load On" and "Set Running", Current transformers of suitable ratings Copper Cables of sultable capacity with Incoming and Outgoing terminations. Required Neutral & body Earthing as per IS 3043. 62.5 KVA DG Set

1

968800

-

... More
DG Room: Design, drawing, Supplying all civil materials, Labour & T&P Providing & constructing of building for DG Sets Size (5x8) m

40

16080

-

... More
Pipe cost

-

-

-

... More
Supply of ISI Marked Centrifugally Cast (Spun) K - 9 Class Ductile Iron Socket & Spigot Pressure Pipes in standard length with internal cement mortar lining and external bituminous coating conforming to IS 8329:2000 and its subsequent amendments & ISI Marked SB/EPDM Rubber Gasket (IS:5382) for Push-on type Flexible Joints of DI Pipes,including inspection, transportation, handling, loading, unloading, stacking, etc. all complete as per specification and direction of Engineer-in-charge. (Cost of rubber gaskets shall be inclusive in the cost of pipes of different diameters.)

-

-

-

... More
200mm dia DI (K7)

6089

2142

-

... More
250mm dia DI (K9)

128

3359

-

... More
300mm dia DI (K9)

219

4250

-

... More
350mm dia DI (K9)

595

5197

-

... More
400mm dia DI (K9)

50

6203

-

... More
Cutting asphalt or bituminous road of flexible pavments and disposal of dismantalled materials up a lead of 1000 mtr stacking servicable and unservicable materials separately including cost of all labour, T & P etc. all complete as per the direction of engineer-in-charge.

262.67

976

-

... More
Cutting concrete road of grannualar course of flexible pavments and disposal of dismantalled materials up a lead of 1000 mtr stacking servicable and unservicable materials separately including cost of all labour, T & P etc. all complete as per the direction of engineer-in-charge.

350.17

1723

-

... More
Supplying all labour, T&P and earth work excavation in following kinds of soil within initial laed of 50m & initial lift of 1.50m including rough fressing breaking clods and laying in layers not exceeding 0.30m. In depth, levelling the bed, using pans, vessels for slushy soil and including sundries supervision charges &labour cess etc, as per direction of Engineer-in-charge

-

-

-

... More
In all kinds of soil(90% as per division)

4685.64

291

-

... More
In D.I Rock(10% as per division)

260.32

683

-

... More
Laying of ISI Marked Centrifugally Cast (Spun) K - 9 Class Ductile Iron Socket & Spigot Pressure Pipes in standard length with internal cement mortar lining and external bituminous coating conforming to IS 8329:2000 and its subsequent amendments & ISI Marked SB/EPDM Rubber Gasket (IS:5382) for Push-on type Flexible Joints of DI Pipes,including inspection, transportation, handling, loading, unloading, stacking, etc. all complete as per specification and direction of Engineer-in-charge.

-

-

-

... More
200mm dia DI (K7)

6089

52

-

... More
250mm dia DI (K9)

128

76

-

... More
300mm dia DI (K9)

219

97

-

... More
350mm dia DI (K9)

595

121

-

... More
400mm dia DI (K9)

50

145

-

... More
Supplying all materials, labour and T&P for providing, laying, fixing & testing of D.I/C.I Specials, Bends, etc. in trenches confirming to IS: 1538 all complete as per specification and direction of Engineer-in-charge including supplying of all labour, material, T&P required to perform to work. (excluding earth work)

-

-

-

... More
Special

-

-

-

... More
200mm dia DI (K7)

91.64

15350

-

... More
250mm dia DI (K9)

2.8

15350

-

... More
300mm dia DI (K9)

6.08

15350

-

... More
350mm dia DI (K9)

20.62

16319

-

... More
400mm dia DI (K9)

2.07

16319

-

... More
Special Laying

-

-

-

... More
200mm dia DI (K7)

91.64

304

-

... More
250mm dia DI (K9)

2.8

304

-

... More
300mm dia DI (K9)

6.08

304

-

... More
350mm dia DI (K9)

20.62

304

-

... More
400mm dia DI (K9)

2.07

304

-

... More
Providing push-on-joints conforming to IS:3114-1994 to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes using Rubber Gaskets Conforming to I.S 5382 of S.B.R quality including testing of joints as per specification complete .

-

-

-

... More
200mm dia DI (K7)

1108

300

-

... More
250mm dia DI (K9)

24

300

-

... More
300mm dia DI (K9)

40

317

-

... More
350mm dia DI (K9)

109

447

-

... More
400mm dia DI (K9)

10

447

-

... More
Fixing cast iron DI Resilient Seated Glandless Gate Valve of RATING PN - 1.60(IS 14846/2000) with double flanged ends (with wheel) for water works purpose for the following rating & nominal diameters but (including cost of Sluice Valves) Make-VAG/Talis/AVK

-

-

-

... More
For Installation/Replacement of Sluice Valve in Existing Water Supply Pipe Line & Newly Proposed Pipeline for controlling flow & scouring Purpose.

-

-

-

... More
150mm Dia Sluice With Hand Wheel & Without bypass arrangements.(P.N 1.6)

1

39050

-

... More
200mm Dia Sluice With Hand Wheel & Without bypass arrangements.(P.N 1.6)

4

65590

-

... More
250mm Dia Sluice With Hand Wheel & Without bypass arrangements.(P.N 1.6)

2

89909

-

... More
300mm Dia Sluice With Hand Wheel & Without bypass arrangements.(P.N 1.6)

2

122948

-

... More
350mm Dia Sluice With Hand Wheel & Without bypass arrangements.(P.N 1.6)

1

188083

-

... More
400mm Dia Sluice With Hand Wheel & Without bypass arrangements.(P.N 1.6)

2

226995

-

... More
Fixing Tamper Proof Kinetic Air Valve conforming to IS 14845 : 2000 for water works purposes for the following diameters including drilling the water main (Cast iron pipes with metal straps) as per specification complete

-

-

-

... More
80mm dia Tamper Proof Kinetic Double Air Valve

12

15975

-

... More
100mm dia Tamper Proof Kinetic Double Air Valve

2

19794

-

... More
Supplying all materials,labour and T&P and constructing brick masonry chamber as per P.H. specification and design all complete including RCC Cover Slab (per each)

-

-

-

... More
Construction of brick masonry sluice valve Chamber of size (0.9mx0.9mx1.5m)

9

21063

-

... More
Construction of brick masonry sluice valve Chamber of size (1mx1mx1.5m)

3

23032

-

... More
Filling in foundation and plinth with excavated materials including watering and ramming as directed by the Engineer-in-charge.

4472.5

162

-

... More
Supplying all materials, labour, T&P and filling in pipe line trenches with sand well watered and rammered including conveyance of all materials to work site, payment of royalty, contractor profit & labour cess etc all complete as per specifiation and direction of Engineer-in-charge.

459.63

1230

-

... More
Supplying all labour and T&P for providing and laying MS pipe and specials confirming to IS 3589/99 of quality grade FE 410/ GI Pipe (Medium ) confirming to specification of following nominal dia and including transportation of pipes and fitting to site etc all complete as per the direction of E.I.C.

-

-

-

... More
200mm dia M.S.Pipe (6.30mm thick)

609

2804

-

... More
200mm dia M.S. Flange.(12mm thick)

152

1541

-

... More
200mm dia Plain Bend

76

10850

-

... More
250mm dia M.S.Pipe (6.30mm thick)

13

3483

-

... More
250mm dia M.S. Flange.(12mm thick)

3

2055

-

... More
250mm dia Plain Bend

2

13420

-

... More
300mm dia M.S.Pipe (6.40mm thick)

22

3754

-

... More
300mm dia M.S. Flange.(12mm thick)

6

2825

-

... More
300mm dia Plain Bend

3

16373

-

... More
350mm dia M.S.Pipe (5.6mm thick)

60

4122

-

... More
350mm dia M.S. Flange.(12mm thick)

15

3468

-

... More
350mm dia Plain Bend

8

18788

-

... More
400 mm dia M.S.Pipe (6.3mm thick)

5

5266

-

... More
400 mm dia M.S. Flange.(20mm thick)

2

4495

-

... More
400mm dia M.S offset bend

2

22308

-

... More
Supplying all labour and T&P for Flame cutting and facing of MS plate or pipes upto 8mm thick including supply of all labor, material, tools & plants for following plate thickness all complete as per specification and direction of Engineer-in-Charge.

97.2

1135

-

... More
Supplying all labour and T&P for Providing joints by welding with two welding beads/pass, conforming to IS:816-1998 ( fillet weld) to MS pipes and fittings at site by using welding generator including testing of joints, as per specification complete

97.2

2566

-

... More
Supplying all materials, labour, t&p and making flanged joints to M.S/ D.I/PVC pipes and specials of the following diameter including testing of joints as per specification all complete.

-

-

-

... More
200mm dia DI (K7)

15

634

-

... More
250mm dia DI (K9)

5

927

-

... More
300mm dia DI (K9)

20

979

-

... More
350mm dia DI (K9)

25

1295

-

... More
400mm dia DI (K9)

6

1770

-

... More
Construction of RCC Thrust Blocks

-

-

-

... More
size 1.00 x 1.00 x 1.00 m

34

17436

-

... More
size 1.50 x 1.50 x 1.30m

6

45997

-

... More
Supplying all materials, labour, T&P and providing cement concrete(1:3:6) with 40cm size crusher broken black hard granite metal including watering, curing, conveyance of all materials to work site, payment of royalty & labour cess etc all complete as per specifications and direction of Engineer-in-charge.(Mending the C.C Road)

306.5

6549

-

... More
Supplying all materials, labour, T&P and providing cement concrete(1:2:4) with 12mm size crusher broken hard granite chips including all cost of conveyance, royalty, sundries, watering for curing, supervision charge, contractor profit & labour cess etc. all complete as p[er the direction of Engineer-in-charge.

306.43

8194

-

... More
Supplying all materials, labour, and T&P for removal/carriage of excavated earth from site to a distance 5 km away etc all complete and as per the specifications and directions of engineer-in-charge.

1346.6

278

-

... More
Design, Supply, Construction, Testing & Commisioning of Mass Balancing Reservoir (MBR) and Elevated Service Reservoirs (ESR's) at Baragada Town all complete as per the direction of Engineer-in-charge.

-

-

-

... More
Proposed ESR-1 -850 KL Staging - 25m--Zone-5A

850000

31

-

... More
Supply Fitting, fixing & commissioning of following dia Pilot Altitude valve for purpose to close valve at a maximum water level of ESR & to open to refill the ESR when the water level in the ESR at lowers.Altitude Control Valve should be worked at minimum pressure 1kg/cm2 .An altitude control valve controls the level of a tank. The altitude valve will remain open while the tank is not full and it will close when the tanks reaches its maximum level. The opening and closing of the valve will work without external power source (electric, pneumatic, or man power), it will work automatically, The body, Spool, & cover will be DI ASTM A-536 standard, Spring, steam, Jam Nut, Cover bolt & cover washer should be SS, DI /SS Diaphragm plate, Nytril/Nylon diaphragm, Bronze cover bushing, Seat plate & ring. Make - (VAG/SINGER/CLA/BURMAD)

-

-

-

... More
250mm dia-Zone-5B

1

441380

-

... More
350 mm dia Zone-6A

1

871010

-

... More
250 mm dia-Zone-6B

1

441380

-

... More
250 mm dia Zone-4

1

441380

-

... More
350mm dia-Zone-5A

1

871010

-

... More
Supplying all materials, Labour & T&P for providing New House connections to beneficiaries from PHE Deptt./ WATCO CI/ DI pipe line to the property of beneficiaries/ Repair of House connection with extension of service etc. including earth work excavation, cutting of concrete / Metal/ BT road, refilling the trenches & making good to the damaged road with CC (1:2:4) after completition of the work, lifting of excess excavated materials/ debrises from work site & disposing within 5 KM radious by mechanical transport, fixing 1/8" dia brass/ GM ferrule with following dia. composite Strap Saddle in the CI/DI pipe line, cutting holes in brick/ stone/ RCC masonary work, repair the broken holes, cost of uPVC Schedule - 80 pipe (25 mm / 20 mm dia up to 7.0mtr /10 mtr respectively ) & fittings, 1 No of PVC Tap of approved make etc. complete as per technical & PH specification and direction of Engineer - in- Charge.

-

-

-

... More
From 100mm dia distribution main

68

3779

-

... More
From 150mm dia distribution main

68

3891

-

... More
Supplying all materials Labour & T & P for fitting & fixing of 20mm dia MDPE pipe (10kgf/cm2) with compression fittings for connection with ferrule & UPVC service pipe of different diameter to make the connection leak proof including cost of required length of 20mm dia MDPE pipe up to 1.0 mtr ,both side elbow/Female threaded elbow/Male threaded elbow/Both side adopter/Male threaded adoptor/ Female threaded adoptor etc.complete as per site condition & ditrection of Engineer in charge.

136

192

-

... More
RCC Framed Boundary Wall (100 M) with Fly Ash Brick Filler Wall

100

8162

-

... More
Pillar and Gate

1

93591

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.