Public Health Engineering Organisation Tender

Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.

Public Health Engineering Organisation - PHEO Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date19 Nov 2024
Closing Date5 Dec 2024
Tender Amount₹ 4,81,86,603 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
2.5cm. Dam proof course with C.C (1:2:4) using 12mm. size hard broken granite chips

48

371

17827.2

... More
Supplying all labour, T&P for Earth filling by mechanical means from approved quarry , compacting , watering including transportation, royalty all complete as per direction iof EIC

168

170

28573.44

... More
Dry stone masonry or rough stone dry masonary for guard walls and retaining walls with granite

144

1980

285177.6

... More
Cement flush pointing to brick masonry ( 1 : 3)

144

193

27921.6

... More
Design,Drawing, construction of Leading Channel for Intake well as per drawing and complete in all respect as per technical specification and as per direction of Engineer-IN-Charge.(Detailed estimate enclosed) Earth work in all kinds of soil within 50mtr initial lead and 1.5mtr initial lift including rough dressing and breaking of clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3mtr in depth as per direction of Engineer-in-charge. (per%cum)

55.8

293

16351.63

... More
Cement concrete (1:3 :6) with 4cm size hard granite metal.

2.79

5732

15992.28

... More
R.C.C work in ground floor of M-20 grade with 20mm & down grade crusher broken Granite chips

24.93

5903

147164.28

... More
Providing, Cutting, Bending. Binding, Hooking, Tying, & Placing in proper position with TOR Steel with cost conveyance and taxes of all material with cost of all labour& T&P required for the work etc. complete

19.94

8687

173218.78

... More
Supplying all materials, labour, T&P and providing rigid and Smooth centering and shuttering for R.C.C. works including False work and dismantling them after casting including Conveyance of all materials to Work site, payment of royalty,contractor profit & labour cess etc all complete as per specification and direction of Engineer-in-charge.Rigid smooth centring and shuttering Slabs

38.7

247

9578.25

122.4

1189

145570.32

... More
Supply Instalation, Testing and commissioning of approved make VFD compatibleV.T pump set of given capacity and head, TEFC squirrel cage solid shaft induction motor working on 3- Phase 50 Hz ± 5%, 0.4KV ± 10%, complete set as per relevant IS and following material of Construction: Impeller with wearing ring CF8M, Shaft with sleeve S.S., Casing- C.I., Column pipe - M.S, Base frame M.S With 2 No. Stand by and 1440 RPM-(4 nos)including third party inspection such as RITES/TUV /PDIL/CIPET/Govt.approved agency Duty condition: discharge-42 lps, head-145 meter

4

1969128

7876512

... More
Construction,Design & drawing of Building for Indoor HT meter Cubicle Room for Intake and complete in all respect as per technical specification and as per direction of Engineer-IN-Charge

16

16080

257280.48

... More
Providing, installation, testing and commissioning of Electromagnetic Flow Meter etc. including all materials(excluding CI/DI fittings) andmaking connection with existing pipeline required forElectromagnetic Flow Meter including cutting the existing pipe line etc. complete in all respect as per technical specification and as per direction of Engineer.(KROCHE MARSHALL,E & H,ADEPT,SIEMENS) 400mm at Inlet to WTP

1

342746

342746

... More
500 mm At outlet of Intake

1

427190

427190

... More
Supply with fitting and fixing of of D.I. Mechanical dismentaling joint for use to main uninterrupted water supply in the pipeline in case eof rpair of Flow meter as per specification and direction of Enginer - in - charge 400mm

1

37737

37737

... More
500 mm

1

55211

55211

... More
Supplying, Fitting,Commissioning,Fixing double chamber DI PN 16 control valve, hydraulically operated, single diaphragm actuated, globe pattern. The valve shall consist of three major components; the body with the seat installed; the cover with the bearing installed and the diaphragm assembly. The diaphragm assembly shall be the only moving part and shall form a sealed chamber in the upper portion of the valve, separating the operating pressure from line pressure. Packing glands, stuffing boxes and there shall be no piston operating the main valve or pilot controls. No fabrication or welding shall be used in the manufacturing process. The control will be achieved by operating a Stainless Steel Float connected from OGR / UGR to the main Valve, integral oriface plate assembly, differential control, reverse flow control, restriction orifice.The Connecting tubing on the Main Valve will be PU or SS with SS fitting from reputed make. The valve shall be working up to 3.0 kg/cm2 operating pressure, Body DI integrated with PLC pannel for operation (local/remort and web enabled with command and control) make CLA/SINGER/HAWLE to control or open & close water supply, including the cost of valve cutting the pipeline & making good to the damages including cost of all labours, T&P etc. all complete as per the direction of Engineer-in-charge. (globe type) 150mm dia D/F actuator Sluice Valve (PN1.6) (KIRLOSKAR/VAGUE/TALIS/HAWLE)

4

147372

589488

... More
150mm dia D/F Non Return Valve (PN1.6)(KIRLOSKAR/VAGUE/TALIS)

4

24946

99784

... More
Enclosure for the LT 630A Capacity ACB control panel board with APFC made out of CR sheet having Size-Height-2000MM X Breadth-4250MM X Depth-1000, Floor mounting with primer coated with Powder coated paint and provided with required gasket for dust / vermin proof with degree of protection IP42 suitable for 415V ,3 phase, 50Hz, 4 wire system fabricated up to 2MM thick (1.6 mm for doors) with panel accessories.{Panel weight consider from analysis}, 630A,4Pole,50kA/EDO, Microprocessor Based Air Circuit Breaker For Main Incomer(Make-SIEMENS/ L&T/ SCHNEIDER/ABB/BCH/C&S), 25A, Breaker control switches (Trip-Neutral-Close).(Make-L&T/ SIEMENS/ ABB/ BCH/ C&S/ SCHNEIDER/ ANCHOR), 25A,Local-Remote, Auto-Manual Switches.(Make-L&T/ SIEMENS/ ABB/ BCH/ C&S/ SCHNEIDER/ ANCHOR), Indicator(Red/Yellow/Green).(Make-L&T/ C&S/ABB/BCH), Indicator(Blue).(Make-L&T/C&S/ABB/BCH), Three phase Digital Ammeter Accuracy class-1.0. (96 x 96 MM/MAKE--SECUR/ C&S/ TECHNO) (l.S), Three phase Digital Volt meter Accuracy class-1.0. (96 x 46 MM/MAKE--SECURE/ C&S/ TECHNO) (L.S), 10A/AC3 Auxiliary Contactor/ 230V .(Make-L&T/ BCH/ TC/ABB/ C&S /SIEMENS/SCHNEIDER/ANCHOR), 6A /4Pole M.C.B.for meter wiring. (Make-L&T/BCH/TC/ABB/C&S), 6A /2Pole M.C.B.for fan & relay wiring. (Make-L&T/BCH/TC/ABB/C&S). Copper Bus-Bar(40MM X10MM)/ (50MM X8MM).Weight consider from analysis, 600/5A VA-15,CL-1,ID-70MM C.T.(Make-KAPPA/AE/ELMEX) (L.S), 50-63A/4Pole M.C.C.B,36kA{For light load-1nos & ancillary load-1nos}.(Make-L&T/ SIEMENS/ ABB/ BCH/ C&S/SCHNEIDER), 1.5MM² single core copper cable. (Make-POLYCAB/ HAVELLS /FINOLEX/KEI)(L.S), 4MM² single core copper cable. (Make-POLYCAB/ HAVELLS /FINOLEX/KEI)(L.S), 10MM² single core copper cable. (Make-POLYCAB/ HAVELLS /FINOLEX/KEI)(L.S) and 1.5MM² Cable Socket (Cop). (Make-KAYCEE/PTR/ DOWELLS) (L.S), 4-6MM² Cable Socket (Cop). (Make-KAYCEE/PTR/ DOWELLS) (L.S), 10MM² Cable Socket (Cop). (Make-KAYCEE/PTR/ DOWELLS) (L.S), 25 X 25 MM PVC Cable Ducts.(Make-L&T/SALZER/ KAYCEE), 25 MM PVC Cable Ducts Cover.(Make-L&T/ SALZER /KAYCEE), 150MM cable Tie.(Make-HOODS/ ELETTRO) (L.S.), 200MM cable Tie.(Make-HOODS/ ELETTRO) (L.S.), PVC Tape(Make-STEELGRIP/ ANCHOR/CONA), MCB fixing Iron Channel / DIN 15/5.5MM - 1M ( suitable for M4 Terminal).(Make-WAGO/SALZER), Finger Type Insulator/one Bus -Bar Support For Capacitor Bank.(Make-RAMANUJ/ WAGO), Bakelite sheet(Thick-4MM, Required size - 10" X 28" = 4nos, 10" X 18" = 10nos, 10" X 8" = 2nos, 28" X 28" = 4nos,35" X 28" = 2nos), 12MM PVC Spiral (L.S.), 25MM X 25MM PVC Mount (L.S.), 2.5MM² Ferrules. 73MM Colour Insulated Heat Shrinkable Sleeves.(Make- RAMANUJ) (L.S), Galvanized coated nut-bolt,Plain washer,Spring washer (L.S.) -All quantity as per requiement.

1

521089

521089

... More
110KW VFD, following specification:- Ambient temperature - -10 to + 50°C; up to + 60°C with derating at 2% per degree rise in temperature. Protection design - IP20 standard, NEMA Type 1-Kit ( optional), IP55/NEMA Type 12 external heatsink ( factory option). Mounting - Horizontal ( 0.75 KW to 75 kW (HD). Overload capacity - 150 % 1 min. (HD, heavy duty) or 110% / 1min. (ND, normal duty. Rated voltage - 200 to 240 VAC, -15 to +10 % 50 / 60 Hz +/-5 %. Output frequency - 0 to 590 Hz. Carrier frequency - 400V Class; 2-15 kHz up to 55KW (ND) ; 2-10 kHz from 75 kW (HD); 2 kHz from 250 kW to 355 kW (ND).Control inputs - 8 digital (sink / source), 3 analog (current/voltage), 1 pulse (HTL, max. 32 kHz), Control output - 4 relay 2 analog ( current/voltage), 1 pulse (HTL, max. 32kHz), 24 Vdc for external sensors available (max. 150 mA) Motor types - Induction Motor ( IM), permanent Magnet Motor (IPM/SPM), Synchronous Reluctance Motor(S (SynRM).Protective functions - Stall prevention, overload prevention,overtemperature prevention - and further protective functions for the motor,the application and the inverter drive. Self-monitoring - Monitoring of main components ( fans, IGBTs, capacitors, charging circuit) with alarm when reaching a certain lifetime.(Make-SIEMENS/ L&T/ SCHNEIDER /ABB/ YASKAWA), 160A/3pole MCCB 50k(Make-L&T/ABB/SIEMENS/BCH/C&S/SCHNEIDER), 250-320A/3Pole M.C.C.B,36kA (Make-L&T/ ABB/ SIEMENS / BCH/ C&S/ SCHNEIDER), Three phase Digital Ammeter Accuracy class-1.0.(96 x 48MM/MAKE--SECUR/C&S/TECHNO), Three phase Digital Volt meter Accuracy class-1.0. (96 x 48 MM/MAKE--SECURE/ C&S/ TECHNO), Indicator(Red/Yellow/Green).(Make-L&T /C&S /ABB /BCH /TC), Indicator(Blue).(Make-L&T/C&S/ABB/BCH/TC), 10"Cooling fan(MAKE-HIGH COOL / SALZER/ KAYCEE), 6A /4Pole M.C.B.for meter wiring. (Make-L&T/BCH/TC/ABB/C&S), 6A /2Pole M.C.B.for control wiring (Make-L&T/BCH/TC/ABB/C&S), and 10A/AC3 Auxiliary Contactor/ 230V .(Make-L&T/ BCH/ TC/ABB/ C&S /SIEMENS/SCHNEIDER/ANCHOR), 315A, Din Type HRC Fuse Links. (Make-L&T/ SIEMENS/ ABB/ BCH/ C&S/SCHNEIDER), 200-800A, Din Type HRC Fuse Base.(Make-L&T/ SIEMENS/ ABB/BCH/ C&S/SCHNEIDER), 1kva(as per VFD control voltage required) Control transformer.-1No, Copper Bus-Bar(30MM X6MM) weight consider from analysis, 300/5A VA-15,CL-1,ID-55MM C.T.(Make-KAPPA/ AE/ ELMEX), Push-Button with Indicator(Make-L&T/BCH/TC/ABB/C&S), Contact Eliment-NO/NC.(Make-L&T/BCH/TC/ABB/C&S), 1.5MM² single core copper cable. (Make-POLYCAB/ HAVELLS /FINOLEX / KEI)(L.S), 1.5MM² Cable Socket (Cop). (Make-KAYCEE/PTR/DOWELLS) (L.S), Single Pole Bus-Bar Support (Make-RAMANUJ/WAGO), 25 X 25 MM PVC Cable Ducts.(Make-L&T/ SALZER/ KAYCEE), 25 MM PVC Cable Ducts Cover.(Make-L&T/ SALZER /KAYCEE), 150MM cable Tie.(Make-HOODS/ ELETTRO) (L.S.), 200MM cable Tie. (Make-HOODS/ ELETTRO) (L.S.), PVC Tape(Make-STEELGRIP/ ANCHOR/CONA) (L.S.), MCB fixing Iron Channel / DIN 15/5.5MM - 1M ( suitable for M4 Terminal). (Make-WAGO/SALZER), 12MM PVC Spiral (L.S.), 25MM X 25MM PVC Mount , 2.5MM² Ferrules, 55MM Colour Insulated Heat Shrinkable Sleeves.(Make- RAMANUJ), Galvanized coated nut-bolt,Plain washer,Spring washer (L.S.) -All quantity as per requiement.

4

315276

1261104

... More
250-320A/3Pole M.C.C.B,36kA (Make-L&T/ ABB/ SIEMENS/BCH/C&S/ SCHNEIDER), 400A/3P/1set of 6 Spreader Terminals. (Make-L&T/ C&S/ BCH/ TC/ABB/SCHNEIDER/SIEMENS), 6A /4Pole M.C.B.for meter wiring. (Make-L&T /BCH /TC/ABB/C&S), 6A /2Pole M.C.B.for fan & relay wiring. (Make-L&T/BCH/TC/ABB/C&S), 10A /3Pole M.C.B.for 5KVAR capacitor(Make-L&T/ ANCHOR /C&S/ABB/BCH/SIEMENS), 20A /3Pole M.C.B.for 10KVAR capacitor(Make-L&T/ MARU/ C&S /ABB/BCH/ANCHOR/LEGRAND), 32A /3Pole M.C.B.for 15KVAR capacitor(Make-L&T/ MARU/ C&S /ABB /BCH /ANCHOR /LEGRAND), 40A /3Pole M.C.B.for 20KVAR capacitor(Make-L&T/ MARU/ C&S /ABB/BCH/ANCHOR/LEGRAND), 1.5MM² single core copper cable. (Make-POLYCAB/ HAVELLS /FINOLEX/KEI) (L.S), 2.5MM² single core copper cable {For 5KVAR Capacitor} (Make-POLYCAB/ HAVELLS /FINOLEX/ KEI) (L.S.), 6MM² single core copper cable {For 20KVAR Capacitor} (Make- POLYCAB/HAVELLS /FINOLEX/ KEI) (L.S.), 4MM² single core copper cable {For 15KVAR Capacitor} (Make- POLYCAB/HAVELLS /FINOLEX/ KEI) (L.S.), Indicator(Red/Yellow/Green).(Make-L&T/C&S/ABB/ BCH), Indicator(Blue).(Make-L&T/C&S/ABB/BCH), Three phase Digital Ammeter Accuracy class-1.0. (96 x 48 MM/MAKE--SECURE) (L.S), Three phase Digital Volt meter Accuracy class-1.0. (96 x 48 MM/MAKE--SECURE) , 1.5MM² Cable Socket (Cop). (Make-KAYCEE/PTR/DOWELLS) , 2.5MM² Cable Socket (Cop). (Make-KAYCEE/PTR/DOWELLS (L.S) , 4-6MM² Cable Socket(Cop).(Make-KAYCEE/PTR/DOWELLS), 200/5A VA-15,CL-1,ID-55MM C.T.(Make-KAPPA/AE/ELMEX), 12 Steps APFC Relay,230V (Make-EPCOS/L&T/C&S), 21kva/0-280V Control transformer, 7KVAR Capacitor duty contactor.(Make-EPCOS/L&T/ C&S), 10KVAR Capacitor duty contactor(Make-EPCOS/ L&T/ C&S) and 20KVAR Capacitor duty contactor(Make-EPCOS/ L&T/ C&S), 5KVAR Capacitor,440V(Make-EPCOS/C&S/L&T), 10KVAR Capacitor,440V(Make-EPCOS/L&T/C&S), 15KVAR Capacitor,440V(Make-EPCOS /L&T /C&S) , 20KVAR Capacitor,440V(Make-EPCOS/L&T/C&S), 4"Cooling fan(MAKE-HIGH COOL / SALZER/ KAYCEE), Copper Bus-Bar(40MM X6MM). (Weight consider from analysis), Single Pole Bus-Bar Support(Make-RAMANUJ /WAGO), Base 2pole connector(Make-RAMANUJ/WAGO) , MCB fixing Iron Channel / DIN 15/5.5MM - 1M ( suitable for M4 Terminal).(Make-WAGO/SALZER), 25 X 25 MM PVC Cable Ducts.(Make-L&T/ SALZER / KAYCEE), 45 X 30 MM PVC Cable Ducts.(Make-L&T/SALZER /KAYCEE), 25 MM PVC Cable Ducts Cover.(Make-L&T/ SALZER /KAYCEE), 45 MM PVC Cable Ducts Cover.(Make-L&T/ SALZER/ KAYCEE), 150MM cable Tie.(Make-HOODS/ELLETRO), 200MM cable Tie.(Make-HOODS/ELLETRO), PVC Tape(Make-STEELGRIP/ ANCHOR/ CONA), 12MM PVC Spiral.(L.S.), 25MM X 25MM PVC Mount, 2.5MM² Ferrules, 73MM Colour Insulated Heat Shrinkable Sleeves. (Make- RAMANUJ), Galvanized coated nut-bolt,Plain washer,Spring washer.(L.S.) -All quantity as per requiement.

1

111895

111895

... More
L.T 300MM²,3½Core/ X 1R,Armoured,Aluminium Cable.(Make-HAVELLS/POLYCAB /FINOLEX/KEI) {For transformer to panel DG to panel)

200

2958

591780

... More
L.T 25MM²,3.5Core/ ,Armoured, Aluminium Cable.(Make-HAVELLS/ POLYCAB /FINOLEX/KEI) {For transformer to panel DG to panel)

50

353

17675

... More
L.T 10MM²,4Core/ ,Armoured, Aluminium Cable.(Make-HAVELLS/ POLYCAB /FINOLEX/KEI) {For transformer to panel DG to panel)

50

281

14070

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/ METAL pipe as required. Above 185MM² and upto 400MM²

200

134

26800

... More
Upto 35MM² AND up to 95MM2(For 4core/10MM²-100Mtr + 16core / 2.5MM²-800Mtr)

50

57

2850

... More
Upto 35MM² (For 4core/10MM²-100Mtr + 16core / 2.5MM²-800Mtr)

50

37

1850

... More
95MM² single core/ X 3R flexible copper cable.(Make-Havells/Polycab/ Finolex/KEI)

300

874

262350

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Above 35MM² and upto 95MM²(cop)

300

92

27600

... More
50MM² Cable Socket(Cop). (Make-KAYCEE/PTR/DOWELLS)(L.S.)

50

40

2046

... More
Supplying and installing following size of perforated painted with powder coating M.S cable trays with perforation not more than 17.5%, in convenient section, joined with connectors, suspended from the celling with M.S suspenders including bolts & nuts, painting suspenders etc as required. 200 mm width X 50 mm depth X 1.6 mm thickness.

30

689

20670

... More
300 mm width X 50 mm depth X 1.6 mm thickness.

50

777

38850

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 240MM² (62mm) {Alu}

4

1195

4780

... More
3 X 95MM² (45mm) {cop}

16

351

5616

... More
Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 240MM² {Alu}

3

2761

8283

... More
Desiging, supplying, installing, commissioning & testing of CCTV IR water proof camera suitable for upto 100ft. with control key board, DVR, Hard Disk,cables, UPT transreceivers etc. complete with not less than following specifications 1. Four numbers of IP Camera with night vision functionality with range up to 30 meters. Camera construction shall be suitable for weather proof outdoor installation. 2. Eight Channe DVR withmetal body consturction, having software features of motion detect recording. 3. 3.5 inch 2 GB HDD 4. 8 port POE Switch 5. 32 inch LED Screen, Keyboard & mouse .Make- Hikvision, CP Plus, Evision, Honeywell all complete as per specification and direction of Engineer-in-charge.

1

56336

56336

... More
Supply, installation and testing of Maintenance free safe Earthing Electrodes with ISI G.I pipe dia 75mm as Secondary electrode with wall thickness of 2.6 mm and the Primary Earthing Electrode will be 50mm X 6mm X 1no M.S hot dipped galavanized strip filled with a highly conductive & non-corrosive compound in between the Primary Earthing and the secondary Earthing, the surface Area in will be 7,06,500sqmm for 3mtrs length and cross sectional primary conducting area is 300 sq.mm An Solid G.I Base plat seals the unit at the bottom and providing of masonry enclosure with cover plate.as per direction of Engg.-in-charg (MES- GFC ground Filling compound will be provided in 25 kgs Bags.) (MES-GFC ground Filling compound will be provided in 25 kgs Bags.) (2 bags required for each earthing electrode.) 2nos earthing connection all motors and 2nos earthing connect in all panel.

4

12061

48247.2

... More
Providing and fixing 25 mm X 5 Mm G.I . Strip on surface or in recess for connections etc. as required.

60

244

14640

... More
First aid Box, Shock treatment chart.(Odia / Hindi & English ), 8MM thick Rubber Mat, Danger Board.(200MM X 1500MM)

1

6015

6015

... More
Providing & Fixing of IK07 IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum LM6/ ADC12 material with heat dissipation fins on housing with UV stabilized PC/Toughened Glass cover (UV stablzation report submitted for UV cover ) and secondary lens on each LED & should be SMD type . The System level Luminaire efficacy =120 lm/ wt with High Power LEDs is to be used and potted driver must be potted & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @=300 V AC and Auto resetting Safety ,Input Frequency 50Hz±3% Power Factor 0.95 driver Efficiency 85% ,THD(I) 70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced. LED Street Light fixture 60 Watt

10

4794

47940

... More
Supply and erection of M.S. Galvanized Octagonal pole ( as per BSEN 40-3-3:2003 /BSEN 10025/IS 2062 IS:875 Part-1 – 2015/ for MS plate for base flange )of following length and dimension as per table P-01 with base plate on the cement concrete foundation of M20 grade (1:1.5:3) as per IS 456/IS 2911. with the help of anchor bolts of grade 6.8 (IS: 1367 P III ). The pole shall have a weatherproof flush door and locking arrangements. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure"A" attached with this BSR .Octagonal MS Poles made of S-355JO grade steel sheet , folded lengthwise to obtained Octagonal shape, having single longitudinal seam weld and hot dipped galvanised internally & externally in accordance with IS 2629(5.0METER HEIGHT)

10

9707

97070

... More
Construction,Design & drawing of Electrical and MCC Control Room single Storey Building complete in all respect as per technical specification and as per direction of Engineer-IN-Charge

72

16080

1157762.16

... More
(5 year )five year operation and maintenance)(Including contribution towards EPF, ESI, Labour cess, Contractors Profit & OH Charges but excluding cost of chemicals & Energy charges) Supply of manpower consisting of 2 no of Numbers of pump driver and 3 no of helper manpower in daily bais including materials require for repair and maintenance of Pump set,VFD Panel, APFC Panel, pipe lines , Sluice valves,air valves,NR Valves, MS pipe laid under this project including painting, repair and replacement of damaged items, spares etcfor the item of the works executed under this project .as per specification and direction of the Engineer-in-charge.

1

7425930

7425930.35



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.