Public Health Engineering Organisation Tender

... More
Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.

Public Health Engineering Organisation - PHEO Tender

Civil And Construction
Water Storage And Supply
Eprocure
Opening Date20 May 2023
Closing Date5 Jun 2023
Tender Amount₹ 1,29,35,231 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Length of 11Kv 3C, 120 sqmm cable (open trench)

-

-

-

... More
Length of 11Kv 3C, 120 sqmm cable (HDD)

-

-

-

... More
Supply of materials for 11Kv, 3 Core, 120sqmm, XLPE insulation armoured UG cable

0.12

96473

803946.19

... More
Supply of Outdoor termination kits Heat Shrinkable type suitable for 11Kv, 3 Core, 120 sqmm HT UG cable for 3 Core (Set)

4

57366

14341.72

... More
Supply of HDPE PE 80-PN8 pipe of 110mm diameter (for 120sqmm HT cable laying)

0.09

49725

565063.39

... More
Erection Portion

-

-

-

... More
Laying, Commissioning, Testing of 11Kv, 3Core, 120sqmm, aluminium, XLPE insulation armoured (estruded type) UG cable by open trench method and HDD method

-

-

-

... More
Laying, Commissioning, Testing of 11Kv, 3Core, 120sqmm, aluminium, XLPE insulation armoured (estruded type) UG cable by open trench method

0.12

11340

94500

... More
Erection of outdoor termination kits Heat Shrinkable type suitable for 11Kv, 3Core, 120sqmm, alluminum UG cable kits for 3core (set)

4

7603

1900.8

... More
Laying of 110mm dia PE 80-PN8, HDPE pipe inside open trench

0.09

9370

104114.67

... More
Civil Portion

-

-

-

... More
Civil works with supply of all materials like cement, MS tor rod, brick, coares & fine aggregates and labour, T&P etc for UG Cable trench

-

-

-

... More
Earth work excavation of soil (1mtr width x 1mtr depth)

-

-

-

... More
Earth work excavation of soil

30.8

6649

215.89

... More
Earth work excavation of hard rock

13.2

19095

1446.6

... More
Shifting of excavated soil to a lead distance of 10Km

26.4

4565

172.92

... More
Filling with fine river sand after laying of cable inside the trench

17.6

6856

389.6

... More
Back filling with excavated soil outside and above the trench

26.4

3135

118.75

... More
Civil works for Prefabricated RCC foundation with supply of all materials

-

-

-

... More
Supply and erection of GI pipe of dia 150mm Class-B (8Mtr)

32

46828

1463.4

... More
Supply and erection of cable Route Marker along the cable route at an interval of 30 mtrs with civil works

2

2024

1012

... More
Part-B:- Installation of 11 KV Outdoor VCB arrangement along with 4 pole, CT, PT, CRP and all acessories at 33/11KV Athagarh PSS.

-

-

-

... More
Material Cost

-

-

-

... More
Top Channel 100x50x6mm @9.56 KG/Mtr x (3mtrx2) (G)

229

23291

101.71

... More
1 Double Pole belting channel 75x40x4.8mm (7.14 KGx3mtrx4) (GI) 2 Support channel for Isolator (3mtrx2) (GI)

385.55

39214

101.71

... More
50x50x6mm GI Bracing Angle @(4.5Kg/Mtr) 3.5 mtr length

252

25630

101.71

... More
Pipe Earthing 40mm dia GI pipe

5

7119

1423.94

... More
50x6mm GI flat for earthing (2.4Kg/mtr)

250

25427

101.71

... More
Lightening Arrester (12KV 10KA) Station Class-2

3

31530

10510

... More
GI Flats 25x3 MM for danger board and anticlimbing device

16

1627

101.71

... More
11 KV 800 AMP isolator with earth switch with PI (Polymer)

1

71671

71671.42

... More
PG clamp for 100 sqmm AAA conducter

9

7078

786.53

... More
160x152mm WPB (11 mtr long) (30.44 Kg per meter) (Each 335.06Kg)

4

122662

30665.53

... More
11 KV Pin insulator (Polymer)

3

813

271.23

... More
11 KV HW fitting (B&S 170 KN 3 Bolt)

18

8568

476

... More
11 KV Disc insulator (B&S) Double Disc 70 KN (Polymer)

18

28071

1559.55

... More
100mm2 AAAC

0.03

2237

74587.1

... More
Black paint

4

1312

328.19

... More
Yellow Paint

4

1193

298.35

... More
GI barbed wire anticlimbing device 3 KG per support

12

1220

101.71

... More
GI Nut Bolt & Washer of different sizes

60

6346

105.78

... More
Danger Plate

4

433

108.49

... More
Materials VCB, CT & CRP

-

-

-

... More
11KV outdoor VCB with 2Core CT & Indoor CR pannel & without PT, with CT (CTR-600-300-15011-1A, STC 25KA/3Sec, class 0.5 & 5P10) feeder protection with numericial relay)

1

376822

376822.29

... More
2 core 2.5 mm2 control cable (Un-armoured) 2XY

50

4610

92.21

... More
4 core 2.5 mm2 control cable (Un-armoured) 2XY

50

7594

151.88

... More
7 core 2.5 mm2 control cable (Un-armoured) 2XY

50

12341

246.82

... More
10 core 2.5 mm2 control cable (Un-armoured) 2XY

50

17494

349.88

... More
Civil Services

-

-

-

... More
Concreting ratio 1:1:5:3 (500mmx500mmx1800mm) = 0.450 mtr

1.8

12402

6890.3

... More
Concreting ratio 1:1:5:3 withdimension(500mmx500mmx450mm) = 0.1125 mtr

0.45

3100

6890.3

... More
Installation of earth pit, Charcoal, Salt etc including construction of earthing chamber (Size 2'x2') and RCC slab cover

5

12035

2407

... More
Foundation for 11KV VCB with CT

1

20000

20000

... More
Part-C:- Construction of 11 KV line on 11 mtr WPB Pole with 55mm2 AAAC over head Bare Conductor for length of 4 CKM from Athagarh PSS to Kaitha Chhawk (Refer SLD B to I)

-

-

-

... More
11 KV Line Length with 50 mtr Span using 55 Sqmm AAA Conductor

-

-

-

... More
No. of DP required without AB switch (Ref. drawing)

-

-

-

... More
Materials of DP without AB Switch

-

-

-

... More
WPB 160x152 (11mtr. Long 30.44KG/Mtr)

8

245324

30665.53

... More
Top channel 100x50x6mm 9.56 KG/Mtr each channel length 2.3 mtr, 2 nos channel required= (2x9.56x2.3)

175.9

17891

101.71

... More
Fish Plate 50x6mm 2.36Kg/mtr each 0.280mtr length, 6 nos required= (6x2.36x0.280)

15.86

1613

101.71

... More
Double Pole Belting channel 75x40x4.8mm 7.14 KG/Mtr each channel length 1.66 mtr, 4 nos channel required = (7.14x1.66x4)

189.64

19288

101.71

... More
50x50x6mm GI Bracing Angle, 4.5 Kg/Mtr, each angle length 2.671 mtr, 4 nos angle required= (4.5x2.671x4)

192.31

19560

101.71

... More
Danger plate, 2 nos

8

867

108.49

... More
Back clamp for danger plate 25x3 mm flat, 0.59Kg/Mtr Flat of 0.510 mtr length 2 nos = (2x0.59x0.510)

2.41

244

101.71

... More
H.T Stay clamp, 50x8mm flat, 3.14Kg/Mtr, 0.551 mtr length, 2 nos qnty required (1 pair)

8

1299

162.42

... More
H.T stay set (Complete)

8

10914

1364.36

... More
H.T stay Insulator Type-C

8

519

64.97

... More
7/10 SWG Stay Wire 15Kg/stay

120

11694

97.45

... More
GI pipe earthing 40mm, 3mtr, Long

4

5695

1423.94

... More
50x6mm GI Flat for earthing, 2.36Kg/Mtr (2.5 mtr for mesh formation and 2.5mtr for raising=5x2.36

47.2

4800

101.71

... More
GI barbed wire anticlimbing devices 3 Kg per support 2 nos qty. required = (2x3Kg)

24

2603

108.49

... More
Back clamp for anticlimbing device 25x3mm flat, 0.59Kg/Mtr Flat of 0.510 mtr length 8 nos = (8x0.59x0.510)

9.63

979

101.71

... More
11KV pin insulator polymer

12

3254

271.23

... More
HW fitting (B&S) 70KN, 3 Bolt

24

11391

474.65

... More
Disc Insulator (B&S) 70 KN Polymer

24

37429

1559.55

... More
PG Clamp for 55 sqmm AAA conductor

24

15622

650.94

... More
GI Nut, Bolt & Washer of different sizes (12.261 Kg each DP without AB Switch)

49.04

5187

105.78

... More
Black Paint

4

1193

298.35

... More
Yellow Colour Paint for Background

8

2386

298.35

... More
Civil & Services

-

-

-

... More
Fixing of complete 11Kv line complete stay set includes 1) Turn Buckle Assembly 2) Stay Rod & Stay plate 3) Stay Insulator 4) Stay Wire 5) Stay clamps with Nuts & bolts BA will do the excavation including excavation, supply of 0.5Cum cement concrete foundation 1:2:4 size (500mmx500mmx800mm) using 20mm BHG metal with all labour and material as per TPCODL drawing & Standard.

8

18000

2250

... More
1:1 5:3 (500mmx500mmx1800mm) = 0.45 Cum

3.6

24805

6890.3

... More
Coupling ration 1:1 5:3 with dimension (500x500x450) = 0.1125 cum

0.9

6201

6890.3

... More
Installation of earth Pit, Charcoal, Salt etc including construction of earthing chamber (size 2'x2') and RCC slab cover

4

9628

2407

... More
No of DP required with AB Switch (Ref. Drawing No-1

-

-

-

... More
MATERIALS OF DP with AB Switch

-

-

-

... More
WPB 160x152 (11Mtr long, 30.44Kg/Mtr)

6

183993

30665.53

... More
Top channel 100x50x6mm, 9.56 Kg/mtr, each channel length 3 mtr, 2 nos channel required = (2x9.56x3)

172.08

17502

101.71

... More
Fish Plate 50x6mm 2.36Kg/mtr each 0.280mtr length, 6 nos required= (6x2.36x0.280)

11.98

1218

101.71

... More
AB switch mounting channel 75x40x4.8mm, 7.14Kg/Mtr each channel length 3 mtr, 2 nos channel required = (7.14x3x2)

128.52

13071

101.71

... More
AB Switch Side Support Channel 100X50X6mm, 9.56 KG/Mtr., each channel length 0.35 mtr., 2 no's channel required =( 9.56x2x0.35)

20.08

2041

101.71

... More
Channel Support for down Pipe 75X40X 4.8mm, 7.14KG/Mtr., each channel length 0.8 Mtr.. 1 no's channel required (7.14x0,8x1)

17.14

1742

101.71

... More
Double Pole Belting Channel 75X40X 4.8mm., 7.14KG/Mtr, each channel length 3.0 Mtr., 4 no's channel required =( 7.14x3x4)

257.04

26143

101.71

... More
50x50x6mm.GI Bracing Angle, 4.5Kg /mtr., each angle length 3.512 mtr., 4 nos angle required= (4.5x3.512x4)

189.65

19289

101.71

... More
Danger Plate, 2 no's.

6

650

108.49

... More
Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 2 no's = (2x0.59x0.510)

1.81

183

101.71

... More
H.T. Stay clarnp, 50x8 mm. flat, 3.14Kg/Mtr., 0.551 Mtr. Length, 2 no's qty. required ( 1 Pair)

6

974

162.42

... More
H.T. Stay set (Complete)

6

8186

1364.36

... More
H.T. Stay Insulator Type-C

6

389

64.97

... More
7/10 SWG Stay Wire 15kg /stay

90

8770

97.45

... More
Gi Pipe Earthing 40mm. 3 Mtr Long

6

8543

1423.94

... More
50x6mm GI Flat for earthing, 2.36kg/mtr., (12.5 Mtr. For L.A, 3 Mtr for AB Switch Body, 2.5 mtr. For mesh formation and 2.5 mtr. For raising) = 20.5x2.36

145.14

14762

101.71

... More
GI barbed wire anticlimbing device 3 Kg. Per support, 2 no's qty required =(2x3kg)

18

1952

108.49

... More
Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 8 no's = (8x0.59x0.510)

7.22

734

101.71

... More
Lightning Arrester(11KV, 10KA) (Station Class,class 2)

9

43328

4814.26

... More
AB Switch (11KV 200A.3pole,50Hz)

3

29902

9967.55

... More
11 KV pin insulator polymer

9

2441

271.23

... More
HW fitting (B&S) 70KN, 3Bolt

18

8543

474.65

... More
Disc insulator (B&S) 70 KN polymer

18

28071

1559.55

... More
PG Clamp for 55 sq.mm AAA conductor

18

11716

650.94

... More
GI Nut, Boit & Washer of different sizes (13.718 Kg each DP with AB Switch)

41.15

4353

105.78

... More
Black Paint

3

895

298.35

... More
Yellow Colour Paint for Background

6

1790

298.35

... More
Civil & Services

-

-

-

... More
Fixing of complete 11Kv line complete stay set includes 1) Turn Buckle Assembly 2) Stay Rod & Stay plate 3) Stay Insulator 4) Stay Wire 5) Stay clamps with Nuts & bolts BA will do the excavation including excavation, supply of 0.5Cum cement concrete foundation 1:2:4 size (500mmx500mmx800mm) using 20mm BHG metal with all labour and material as per TPCODL drawing & Standard.

6

13500

2250

... More
Concreting ratio 1:1:5:3 (500mmx500mmx1800mm) = 0.450 mtr

2.7

18603

6890.3

... More
Concreting ratio 1:1:5:3 withdimension(500mmx500mmx450mm) = 0.1125 mtr

0.68

4685

6890.3

... More
Installation of earth pit, Charcoal, Salt etc including construction of earthing chamber (Size 2'x2') and RCC slab cover

6

14442

2407

... More
No of Cut Point with 180 Degree Angle (ef. Drawing

-

-

-

... More
MATERIALS FOR KV Cut Point with 180 Degree Angle

-

-

-

... More
WPB 160x152 (11Mtr Long, 30 44KG/Mtr)

10

306655

30665.53

... More
Straight Cross Arm 100X50X6mm, 9.56 KG/Mtr., each channel length 1.2 mtr., 2 no's channel required =(2x9.56x1.2)

229.44

23336

101.71

... More
Fish Plate 50x6 mm., 2.36 kg/Mtr., each 0.280 mtr. length, 8 no's required=(8x2.36x0.280)

52.86

5376

101.71

... More
Straight Cross Arm 100X50X6mm, 9.56 KG/Mtr., each channel length 0.306 mtr, 2 no's channel required =(2x9.56x0.306)

58.51

5950

101.71

... More
Danger Plate, 1 no's.

10

1017

101.71

... More
Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 1 no's = (1x0.59x0.510)

3.01

306

101.71

... More
Gi barbed wire anticlimbing device 3 Kg. Per support

30

3254

108.49

... More
Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr, Flat of 0.510mtr length 4 no's = (4x0.59x0.510)

12.04

1224

101.71

... More
11 KV pin insulator polymer

30

8136

271.23

... More
H W fitting (B&S) 70KN, 3Bolt

60

28479

474.65

... More
Disc insulator (B&S) 70 KN polymer

60

93573

1559.55

... More
Earthing of Support (Coil Type

10

2251

225.12

... More
No-8 Gl wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing

2.62

266

101.71

... More
PG Clamp for 55 sq.mm AAA conductor

60

39056

650.94

... More
GI Nut, Boit & Washer of different sizes (13.718 Kg each DP with AB Switch)

35.5

3755

105.78

... More
Black Paint

5

1491

298.35

... More
Yellow Colour Paint for Background

20

5967

298.35

... More
Civil & Services

-

-

-

... More
1:1 5:3 (500mmx500mmx1800mm) = 0.45 Cum

4.5

31006

6890.3

... More
Coupling ration 1:1 5:3 with dimension (500x500x450) = 0.1125 cum

1.13

7786

6890.3

... More
No of Cut Point with 180 Degree Angle (ef. Drawing

-

-

-

... More
MATERIALS FOR KV Cut Point with 90 Degree Angle

-

-

-

... More
WPB 160x152 (11Mtr Long, 30 44KG/Mtr)

2

61331

30665.53

... More
Straight Cross Arm 100X50X6mm, 9.56 KG/Mtr., each channel length 1.2 mtr., 2 no's channel required =(2x9.56x1.2)

91.78

9334

101.71

... More
Fish Plate 50x6 mm., 2.36 kg/Mtr., each 0.280 mtr. length, 8 no's required=(8x2.36x0.280)

21.15

2150

101.71

... More
Straight Cross Arm 100X50X6mm, 9.56 KG/Mtr., each channel length 0.306 mtr, 2 no's channel required =(2x9.56x0.306)

23.4

2380

101.71

... More
Danger Plate, 1 no's.

2

203

101.71

... More
Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 1 no's = (1x0.59x0.510)

0.6

61

101.71

... More
Gi barbed wire anticlimbing device 3 Kg. Per support

30

3254

108.49

... More
Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr, Flat of 0.510mtr length 4 no's = (4x0.59x0.510)

12.04

1224

101.71

... More
11 KV pin insulator polymer

6

1627

271.23

... More
H W fitting (B&S) 70KN, 3Bolt

12

5695

474.65

... More
Disc insulator (B&S) 70 KN polymer

12

18714

1559.55

... More
Earthing of Support (Coil Type

2

450

225.12

... More
No-8 Gl wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing

0.52

53

101.71

... More
PG Clamp for 55 sq.mm AAA conductor

12

7811

650.94

... More
H.T. Stay clarnp, 50x8 mm. flat, 3.14Kg/Mtr., 0.551 Mtr. Length, 2 no's qty. required ( 1 Pair)

4

649

162.42

... More
H.T. Stay set (Complete)

4

5457

1364.36

... More
H.T. Stay Insulator Type-C

4

259

64.97

... More
7/10 SWG Stay Wire 15kg /stay

60

5847

97.45

... More
GI Nut, Boit & Washer of different sizes (13.718 Kg each DP with AB Switch)

14.87

1572

105.78

... More
Black Paint

1

298

298.35

... More
Yellow Colour Paint for Background

4

1193

298.35

... More
Civil & Services

-

-

-

... More
Fixing of complete 11Kv line complete stay set includes 1) Turn Buckle Assembly 2) Stay Rod & Stay plate 3) Stay Insulator 4) Stay Wire 5) Stay clamps with Nuts & bolts BA will do the excavation including excavation, supply of 0.5Cum cement concrete foundation 1:2:4 size (500mmx500mmx800mm) using 20mm BHG metal with all labour and material as per TPCODL drawing & Standard.

4

9000

2250

... More
Concreting ratio 1:1:5:3 (500mmx500mmx1800mm) = 0.450 mtr

0.9

6201

6890.3

... More
Coupling ratio 1:1:5:3 withdimension(500mmx500mmx450mm) = 0.1125 mtr

0.2

1378

6890.3

... More
11KV line length in KM with 50 mtr Span ref.

-

-

-

... More
MATERIALS FOR 11 KV Pin Points with WPB

-

-

-

... More
WPB 160x152 (11Mtr Long, 30 44KG/Mtr)

64

1962593

30665.53

... More
11KV V cross Arm (10.2 Kg each)

64

70302

1098.47

... More
Top bracket 100x50x6 mm GI channel (2Kg each)

64

13018

203.42

... More
Danger Plate, 1 no's. for each pole

64

6943

108.49

... More
Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 1 no's = (1x0.59x0.510)

19.26

1958

101.71

... More
Gi barbed wire anticlimbing device 3 Kg. Per support

192

20830

108.49

... More
Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr, Flat of 0.510mtr length 4 no's = (4x0.59x0.510)

77.03

7834

101.71

... More
11 KV pin insulator polymer, 3 nos, required for each support

192

52076

271.23

... More
Earthing of Support (Coil Type

64

14407

225.12

... More
No-8 Gl wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing

16.77

1705

101.71

... More
GI Nut, Boit & Washer of different sizes (1.45 Kg/ Pin point)

92.8

9816

105.78

... More
55 mm2 AAAC

12.36

502852

40683.87

... More
Crimping type Midspan Compression Joint for 55 sqmm AAA conductor

12

3873

322.83

... More
Black Paint

64

19094

298.35

... More
Yellow Colour Paint for Background

128

38188

298.35

... More
Civil & Services

-

-

-

... More
Concreting ratio 1:1:5:3 (500mmx500mmx1800mm) = 0.450 mtr

28.8

198440

6890.3

... More
Coupling ratio 1:1:5:3 withdimension(500mmx500mmx450mm) = 0.1125 mtr

7.2

49610

6890.3

... More
Part-D:- Construction of 11 KV line on 11 mtr WPB Pole with 70mm2 AAA 11KV XLPE covered conductor for length of 3 CKM from Kaitha Chhaka to proposed DP at consumer premises. (Refer SLD i to S)

-

-

-

... More
11 KV line length with 50 mtr span using 70sqmm -AAA XLPE covered conductor

-

-

-

... More
No of DP required with AB switch (Ref. drawing No-TPCODL-MVD-0001)

-

-

-

... More
WPB 160x152 (11Mtr long, 30.44Kg/Mtr)

2

61331

30665.53

... More
Top channel 100x50x6mm, 9.56 Kg/mtr, each channel length 3 mtr, 2 nos channel required = (2x9.56x3)

57.36

5834

101.71

... More
Fish Plate 50x6mm 2.36Kg/mtr each 0.280mtr length, 6 nos required= (6x2.36x0.280)

3.96

403

101.71

... More
AB switch mounting channel 75x40x4.8mm, 7.14Kg/Mtr each channel length 3 mtr, 2 nos channel required = (7.14x3x2)

42.84

4357

101.71

... More
AB Switch Side Support Channel 100X50X6mm, 9.56 KG/Mtr., each channel length 0.35 mtr., 2 no's channel required =( 9.56x2x0.35)

6.69

680

101.71

... More
Channel Support for down Pipe 75X40X 4.8mm, 7.14KG/Mtr., each channel length 0.8 Mtr.. 1 no's channel required (7.14x0,8x1)

5.71

580

101.71

... More
Double Pole Belting Channel 75X40X 4.8mm., 7.14KG/Mtr, each channel length 3.0 Mtr., 4 no's channel required =( 7.14x3x4)

85.68

8714

101.71

... More
50x50x6mm.GI Bracing Angle, 4.5Kg /mtr., each angle length 3.512 mtr., 4 nos angle required= (4.5x3.512x4)

63.22

6429

101.71

... More
Danger Plate, 2 no's.

2

216

108.49

... More
Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 2 no's = (2x0.59x0.510)

0.6

61

101.71

... More
H.T. Stay clarnp, 50x8 mm. flat, 3.14Kg/Mtr., 0.551 Mtr. Length, 2 no's qty. required ( 1 Pair)

2

324

162.42

... More
H.T. Stay set (Complete)

2

2728

1364.36

... More
H.T. Stay Insulator Type-C

2

129

64.97

... More
7/10 SWG Stay Wire 15kg /stay

30

2923

97.45

... More
Gi Pipe Earthing 40mm. 3 Mtr Long

2

2847

1423.94

... More
50x6mm GI Flat for earthing, 2.36kg/mtr., (12.5 Mtr. For L.A, 3 Mtr for AB Switch Body, 2.5 mtr. For mesh formation and 2.5 mtr. For raising) = 20.5x2.36

48.38

4920

101.71

... More
GI barbed wire anticlimbing device 3 Kg. Per support, 2 no's qty required =(2x3kg)

6

650

108.49

... More
Spikle (GI) (using 50x6mm Flat welded with 8mm square bar) (2 Nos of spike per set in each pole)

4

3979

994.76

... More
Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 8 no's = (8x0.59x0.510)

2.41

244

101.71

... More
Lightning Arrester(11KV, 10KA) (Station Class,class 2)

3

14442

4814.26

... More
AB Switch (11KV 200A.3pole,50Hz)

1

9967

9967.55

... More
11 KV pin insulator polymer

3

813

271.23

... More
Insulated Ties (Top) for 11KV Polymer Pin insulator

3

855

285.24

... More
11KV, 90KN, Polymer Tension insulator (B&S) with Clamp, Nut & Bolts

6

6558

1093.03

... More
11KV, 90KN, 4 Bolted type single Tension Hardware fittings (B&S) with clamp, Nut & Bolts suitable for covered conductor

6

6953

1158.95

... More
Insulating Piercing connector (IPC)

6

1510

251.69

... More
GI Nut, Boit & Washer of different sizes (13.718 Kg each DP with AB Switch)

13.72

1451

105.78

... More
Black Paint

1

298

298.35

... More
Yellow Colour Paint for Background

2

596

298.35

... More
Civil & Services

-

-

-

... More
Fixing of complete 11Kv line complete stay set includes 1) Turn Buckle Assembly 2) Stay Rod & Stay plate 3) Stay Insulator 4) Stay Wire 5) Stay clamps with Nuts & bolts BA will do the excavation including excavation, supply of 0.5Cum cement concrete foundation 1:2:4 size (500mmx500mmx800mm) using 20mm BHG metal with all labour and material as per TPCODL drawing & Standard.

2

4500

2250

... More
Concreting ratio 1:1:5:3 (500mmx500mmx1800mm) = 0.450 mtr

0.9

6201

6890.3

... More
Coupling ratio 1:1:5:3 withdimension(500mmx500mmx450mm) = 0.1125 mtr

0.23

1584

6890.3

... More
Installation of earth pit, Charcoal, Salt etc including construction of earthing chamber (Size 2'x2') and RCC slab cover

2

4814

2407

... More
No of Cut Point with 180 Degree Angle (ref. Drawing No-TPCODL-MVD-0004)

-

-

-

... More
WPB 160x152 (11Mtr Long, 30 44KG/Mtr)

8

245324

30665.53

... More
Straight Cross Arm 100X50X6mm, 9.56 KG/Mtr., each channel length 1.2 mtr., 2 no's channel required =(2x9.56x1.2)

183.55

18669

101.71

... More
Fish Plate 50x6 mm., 2.36 kg/Mtr., each 0.280 mtr. length, 8 no's required=(8x2.36x0.280)

42.29

4301

101.71

... More
Straight Cross Arm 100X50X6mm, 9.56 KG/Mtr., each channel length 0.306 mtr, 2 no's channel required =(2x9.56x0.306)

46.81

4760

101.71

... More
Danger Plate, 1 no's.

8

813

101.71

... More
Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 1 no's = (1x0.59x0.510)

2.41

244

101.71

... More
Gi barbed wire anticlimbing device 3 Kg. Per support

24

2603

108.49

... More
Spikle (GI) (using 50x6mm Flat welded with 8mm square bar) (2 Nos of spike per set in each pole)

16

15916

994.76

... More
Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 4 no's = (4x0.59x0.510)

9.63

979

101.71

... More
11 KV pin insulator polymer

24

6509

271.23

... More
Insulated Ties (Top) for 11KV Polymer Pin insulator

24

6845

285.24

... More
11KV, 90KN, Polymer Tension insulator (B&S) with Clamp, Nut & Bolts

48

52465

1093.03

... More
11KV, 90KN, 4 Bolted type single Tension Hardware fittings (B&S) with clamp, Nut & Bolts suitable for covered conductor

48

55629

1158.95

... More
Earthing of Support (Coil Type

8

1800

225.12

... More
No-8 Gl wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing

2.1

213

101.71

... More
Insulating Piercing connector (IPC)

48

12081

251.69

... More
GI Nut, Boit & Washer of different sizes (13.718 Kg each DP with AB Switch)

28.4

3004

105.78

... More
Black Paint

4

1193

298.35

... More
Yellow Colour Paint for Background

16

4773

298.35

... More
Civil & Services

-

-

-

... More
Concreting ratio 1:1:5:3 (500mmx500mmx1800mm) = 0.450 mtr

3.6

24805

6890.3

... More
Coupling ratio 1:1:5:3 withdimension(500mmx500mmx450mm) = 0.1125 mtr

0.9

6201

6890.3

... More
No of Cut Point with 90 Degree Angle (ref. Drawing No-TPCODL-MVD-0005)

-

-

-

... More
MATERIALS FOR 11 KV Cut Point with 90 Degree Angle

-

-

-

... More
WPB 160x152 (11Mtr Long, 30 44KG/Mtr)

5

153327

30665.53

... More
Straight Cross Arm 100X50X6mm, 9.56 KG/Mtr., each channel length 1.2 mtr., 2 no's channel required =(2x9.56x1.2)

229.44

23336

101.71

... More
Fish Plate 50x6 mm., 2.36 kg/Mtr., each 0.280 mtr. length, 8 no's required=(8x2.36x0.280)

52.86

5376

101.71

... More
Straight Cross Arm 100X50X6mm, 9.56 KG/Mtr., each channel length 0.306 mtr, 2 no's channel required =(2x9.56x0.306)

58.51

5950

101.71

... More
Danger Plate, 1 no's.

5

508

101.71

... More
Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 1 no's = (1x0.59x0.510)

1.5

152

101.71

... More
Gi barbed wire anticlimbing device 3 Kg. Per support

24

2603

108.49

... More
Spikle (GI) (using 50x6mm Flat welded with 8mm square bar) (2 Nos of spike per set in each pole)

16

15916

994.76

... More
Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 4 no's = (4x0.59x0.510)

9.63

979

101.71

... More
11 KV pin insulator polymer

15

4068

271.23

... More
Insulated Ties (Top) for 11KV Polymer Pin insulator

15

4278

285.24

... More
11KV, 90KN, Polymer Tension insulator (B&S) with Clamp, Nut & Bolts

30

32790

1093.03

... More
11KV, 90KN, 4 Bolted type single Tension Hardware fittings (B&S) with clamp, Nut & Bolts suitable for covered conductor

30

34768

1158.95

... More
Earthing of Support (Coil Type

5

1125

225.12

... More
No-8 Gl wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing

1.31

133

101.71

... More
Insulating Piercing connector (IPC)

30

7550

251.69

... More
H.T. Stay clarnp, 50x8 mm. flat, 3.14Kg/Mtr., 0.551 Mtr. Length, 2 no's qty. required ( 1 Pair)

10

1624

162.42

... More
H.T. Stay set (Complete)

10

13643

1364.36

... More
H.T. Stay Insulator Type-C

10

649

64.97

... More
7/10 SWG Stay Wire 15kg /stay

150

14617

97.45

... More
GI Nut, Boit & Washer of different sizes (13.718 Kg each DP with AB Switch)

37.17

3931

105.78

... More
Black Paint

2.5

745

298.35

... More
Yellow Colour Paint for Background

10

2983

298.35

... More
Civil & Services

-

-

-

... More
Fixing of complete 11Kv line complete stay set includes 1) Turn Buckle Assembly 2) Stay Rod & Stay plate 3) Stay Insulator 4) Stay Wire 5) Stay clamps with Nuts & bolts BA will do the excavation including excavation, supply of 0.5Cum cement concrete foundation 1:2:4 size (500mmx500mmx800mm) using 20mm BHG metal with all labour and material as per TPCODL drawing & Standard.

10

22500

2250

... More
Concreting ratio 1:1:5:3 (500mmx500mmx1800mm) = 0.450 mtr

2.3

15847

6890.3

... More
Coupling ratio 1:1:5:3 withdimension(500mmx500mmx450mm) = 0.1125 mtr

0.6

4134

6890.3

... More
11KV line length in KM with 50 mtr Span ref.

-

-

-

... More
Drawing No. TPCODL-MVD-0003)

-

-

-

... More
MATERIALS FOR 11 KV Pin Points with WPB

-

-

-

... More
WPB 160x152 (11Mtr Long, 30 44KG/Mtr)

49

1502610

30665.53

... More
11KV V cross Arm (10.2 Kg each)

49

53825

1098.47

... More
Top bracket 100x50x6 mm GI channel (2Kg each)

49

9967

203.42

... More
Danger Plate, 1 no's. for each pole

49

5316

108.49

... More
Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 1 no's = (1x0.59x0.510)

14.74

1499

101.71

... More
Gi barbed wire anticlimbing device 3 Kg. Per support

147

15948

108.49

... More
Spikle (GI) (using 50x6mm Flat welded with 8mm square bar) (2 Nos of spike per set in each pole)

96

95496

994.76

... More
Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 4 no's = (4x0.59x0.510)

58.98

5998

101.71

... More
11 KV pin insulator polymer

147

39870

271.23

... More
Insulated Ties (Top) for 11KV Polymer Pin insulator

147

41930

285.24

... More
Earthing of Support (Coil Type

49

11030

225.12

... More
No-8 Gl wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing

13

1322

101.71

... More
GI Nut, Boit & Washer of different sizes (1.45/ Kg pin point

71.05

7515

105.78

... More
11KV, 70mm2, Single core, AAAC over head covered conductor

9.27

3721879

401497.3

... More
11KV Mid Span compression jointing kit for covered conductor

9

2804

311.61

... More
Black Paint

49

14619

298.35

... More
Yellow Colour Paint for Background

98

29238

298.35

... More
Civil & Services

-

-

-

... More
Concreting ratio 1:1:5:3 (500mmx500mmx1800mm) = 0.450 mtr

22.05

151931

6890.3

... More
Coupling ratio 1:1:5:3 withdimension(500mmx500mmx450mm) = 0.1125 mtr

5.51

37965

6890.3

... More
Part-E:- Construction of 11 KV line Protecting Guarding for village Road Crossing (SP) - 9 Nos with 15 meter span each

-

-

-

... More
No of 11 KV line protecing Guarding (SP)

-

-

-

... More
MATERIALS FOR 11KV line Protection Guarding For Road Crossing

-

-

-

... More
Top channel 100x50x6mm, 9.56 Kg/mtr, each channel length 2.2 mtr, 4 nos channel required = (4x9.56x2.2)

757.15

77009

101.71

... More
No -6 GI wire (0.192 Kg/mtr) for main string

51.84

5272

101.71

... More
No -8 GI wire (0.131 Kg/mtr) for lacing

23.58

2398

101.71

... More
Eye Bolt (236mm, 16mm dia, 1.577 Kg/Mtr)

36

2929

81.37

... More
Part-F:- Installation of one DP with AB Switch for HT metering unit

-

-

-

... More
No of WPB Pole= 02, AB Switch=01

-

-

-

... More
Materials Of DP with AB Switch

-

-

-

... More
WPB 160x152 (11Mtr long, 30.44Kg/Mtr)

2

61331

30665.53

... More
Top channel 100x50x6mm, 9.56 Kg/mtr, each channel length 3 mtr, 2 nos channel required = (2x9.56x3)

57.36

5834

101.71

... More
Fish Plate 50x6mm 2.36Kg/mtr each 0.280mtr length, 6 nos required= (6x2.36x0.280)

3.96

403

101.71

... More
AB switch mounting channel 75x40x4.8mm, 7.14Kg/Mtr each channel length 3 mtr, 2 nos channel required = (7.14x3x2)

42.84

4357

101.71

... More
HT MU Mounting chanel 75x40x4.8mm, 7.14Kg/Mtr, each channel lemgth 3 mtr, 2 nos channel required = (7.14x3x2)

42.84

4357

101.71

... More
AB Switch Side Support Channel 100X50X6mm, 9.56 KG/Mtr., each channel length 0.35 mtr., 2 no's channel required =( 9.56x2x0.35)

6.69

680

101.71

... More
Channel Support for down Pipe 75X40X 4.8mm, 7.14KG/Mtr., each channel length 0.8 Mtr.. 1 no's channel required (7.14x0,8x1)

5.71

580

101.71

... More
Double Pole Belting Channel 75X40X 4.8mm., 7.14KG/Mtr, each channel length 3.0 Mtr., 4 no's channel required =( 7.14x3x4)

42.84

4357

101.71

... More
50x50x6mm.GI Bracing Angle, 4.5Kg /mtr., each angle length 3.512 mtr., 2 nos angle required= (4.5x3.512x24)

31.61

3214

101.71

... More
Danger Plate, 2 no's.

2

216

108.49

... More
Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 2 no's = (2x0.59x0.510)

0.6

61

101.71

... More
55mm2 All Alloy Aluminum conductor (AAAC) - PVC insulated for jumpering

0.02

1013

67589.2

... More
H.T. Stay clarnp, 50x8 mm. flat, 3.14Kg/Mtr., 0.551 Mtr. Length, 2 no's qty. required ( 1 Pair)

2

324

162.42

... More
H.T. Stay set (Complete)

2

2728

1364.36

... More
H.T. Stay Insulator Type-C

2

129

64.97

... More
7/10 SWG Stay Wire 15kg /stay

30

2923

97.45

... More
Gi Pipe Earthing 40mm. 3 Mtr Long

2

2847

1423.94

... More
50x6mm GI Flat for earthing, 2.36kg/mtr., (12.5 Mtr. For L.A, 3 Mtr for AB Switch Body, 2.5 mtr. For mesh formation and 2.5 mtr. For raising) = 20.5x2.36

48.38

4920

101.71

... More
GI barbed wire anticlimbing device 3 Kg. Per support, 2 no's qty required =(2x3kg)

6

650

108.49

... More
Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 8 no's = (8x0.59x0.510)

2.41

244

101.71

... More
Lightning Arrester(11KV, 10KA) (Station Class,class 2)

3

14442

4814.26

... More
AB Switch (11KV 200A.3pole,50Hz)

1

9967

9967.55

... More
11 KV pin insulator polymer

3

813

271.23

... More
HW fitting (B&S) 70KN, 3Bolt

6

2847

474.65

... More
Disc insulator (B&S) 70 KN polymer

6

9357

1559.55

... More
PG clamp for 55sqmm AAA conductor

6

3905

650.94

... More
GI Nut Bolt & washer of differentb sizes (13.718 Kg/ each DP with AB switch)

13.72

1451

105.78

... More
Black Paint

1

298

298.35

... More
Yellow Colour Paint for Background

2

596

298.35

... More
Civil & Services

-

-

-

... More
Fixing of complete 11Kv line complete stay set includes 1) Turn Buckle Assembly 2) Stay Rod & Stay plate 3) Stay Insulator 4) Stay Wire 5) Stay clamps with Nuts & bolts BA will do the excavation including excavation, supply of 0.5Cum cement concrete foundation 1:2:4 size (500mmx500mmx800mm) using 20mm BHG metal with all labour and material as per TPCODL drawing & Standard.

2

4500

2250

... More
Concreting ratio 1:1:5:3 (500mmx500mmx1800mm) = 0.450 mtr

0.9

6201

6890.3

... More
Coupling ratio 1:1:5:3 withdimension(500mmx500mmx450mm) = 0.1125 mtr

0.23

1584

6890.3

... More
Installation of earth pit, Charcoal, Salt etc including construction of earthing chamber (Size 2'x2') and RCC slab cover

2

4814

2407

... More
Supply and Erection of GI Fencing with Gate

20

72000

3600



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.