Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.

Public Health Engineering Organisation - PHEO Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date19 Nov 2024
Closing Date5 Dec 2024
Tender Amount₹ 6,28,75,576 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
R.C.C work in ground floor of M-20 grade with 20mm & down grade crusher broken Granite chips

24.93

5780

144097.89

... More
Providing, Cutting, Bending. Binding, Hooking, Tying, & Placing in proper position with TOR Steel with cost conveyance and taxes of all material with cost of all labour& T&P required for the work etc. complete taking 0.80 Qtl / cum of RCC

19.94

8687

173220.77

... More
Rigid smooth centring and shuttering, Slab

38.7

755

29218.5

... More
Rigid smooth centring and shuttering, Walls

122.4

1061

129903.12

... More
Stone pitching Supplying all labour, T&P and Earth work in excavation of all kinds of Soil with in 50m intial lead and 1.5m intitial lift including rough dressing and breaking the clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth as per direction of E.I.C

57.6

293

16879.1

... More
Random rubble H.G. stone Masonry in cement mortar (1:6) in foundation and plinth.

90

4289

386037

... More
2.5cm. Dam proof course with C.C (1:2:4) using 12mm. size hard broken granite chips

24

368

8839.2

... More
Supplying all labour, T&P for Earth filling by mechanical means from approved quarry , compacting , watering including transportation, royalty all complete as per direction iof EIC

84

170

14286.72

... More
Dry stone masonry or rough stone dry masonary for guard walls and retaining walls with granite

72

1835

132177.6

... More
Supply Instalation, Testing and commissioning of approved make V.T pump set of given capacity and head with VFD compatible, TEFC squirrel cage solid shaft induction motor working on 3- Phase 50 Hz ± 5%, 0.4KV ± 10%, complete set as per relevant IS and following material of Construction: Impeller with wearing ring CF8M, Shaft with sleeve S.S., Casing- C.I., Column pipe - M.S, Base frame M.S With 2 No. Stand by and 1440 RPM (including third party inspection such as RITES/TUV /PDIL/CIPET/Govt.approved agency)-4Nos Duty Condition:Head-115 meter,discharge-76 LPS

4

2726485

10905940.8

... More
Providing, installation, testing and commissioning of Electromagnetic Flow Meter etc. including all materials(excluding CI/DI fittings) andmaking connection with existing pipeline required forElectromagnetic Flow Meter including cutting the existing pipe line etc. complete in all respect as per technical specification and as per direction of Engineer. 600mm dia

1

492301

492301

... More
Supply with fitting and fixing of of D.I. Mechanical dismentaling joint for use to main uninterrupted water supply in the pipeline in case eof rpair of Flow meter as per specification and direction of Enginer - in - charge 600 mm dia

1

67838

67838

... More
250mm dia D/F actuator Sluice Valve (PN1.6) (KIRLOSKAR/VAGUE/TALIS)

4

193168

772672

... More
250mm dia D/F Non Return Valve (PN1.6)(KIRLOSKAR/VAGUE/TALIS)

4

73705

294820.8

... More
Approach bridge for Intake Earth work in excavation of all kinds of Soil with in 50m intial lead and 1.5m intitial lift including rough dressing and breaking the clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth as per direction of E.I.C

144

293

42197.76

... More
Filling in foundation and plinth with excavated materials including watering and ramming as directed by the Engineer-in-charge.

240

162

39072.48

... More
Cement concrete (1:2:4) with 20mm size broken hard granite broken chips per 1 Cu.m.

43.84

7241

317444.11

... More
R.C.C work in ground floor of M-35 grade with 20mm & down grade crusher broken hard Granite chips including hoisting & laying with cost of all labour, materials with all taxes, lead ,T & P etc all complete .

266.5

6295

1677750.75

... More
R.C.C work in ground floor of M-25 grade with 20mm & down grade crusher broken hard Granite chips including hoisting & laying with cost of all labour, materials with all taxes, lead ,T & P etc all complete .(Railling)

100

6166

616660

... More
.C.C work in ground floor of M-30 grade with 20mm & down grade crusher broken hard Granite chips including hoisting & laying with cost of all labour, materials with all taxes, lead ,T & P etc all complete .

3.68

6189

22746.78

... More
M.S. Reinforcement for R.C.C. works including cutting,bending, binding and tying grills and placing in position including cost of M.S.Rods, binding wire 18 to 20 gauge.

27.02

8687

234708.07

... More
Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification.

25.68

2507

64400.3

... More
Providing and laying boulders apron on river bed for protection against scour with stone boulders weighing not less than 40 kg each complete as per drawing and Technical specification.

28

1764

49406

... More
Providing weep holes in Brick masonry/Plain/ Reinforced concrete abutment, wing wall/ return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical Specifications

13

118

1536.6

... More
Providing and laying of asphaltic plug joint to provide for horizontal movement of 25 mm and vertical movement of 2 mm, depth of joint varying from 75 mm to 100 mm, width varying from 500 mm to 750 mm (in traffic direction), covered with a closure plate of 200mm x 6mm of weldable structural steel conforming to IS: 2062, asphaltic plug to consist of polymer modified bitumen binder, carefully selected single size aggregate of 12.5 mm nominal size and a heat resistant foam caulking/backer rod, all as per approved drawings and specifications.

24

1402

33648

... More
Providing and laying 12 mm thick mastic asphalt wearing course on top of deck slab excluding prime coat with paving grade bitumen meeting the requirements given in table 500-29, prepared by using mastic cooker and laid to required level and slope after cleaning the surface, including providing antiskid surface with bitumen precoated fine grained hard stone chipping of 9.5 mm nominal size at the rate of 0.005cum per 10 sqm and at an approximate spacing of 10 cm center to center in both directions, pressed into surface when the temperature of surfaces not less than 100 deg. C, protruding 1 mm to 4 mm over mastic surface, all complete as per clause 515.

175

687

120312.5

... More
Feeder panel:- Supply,Fitting & fixing of Enclosure for the LT 800A Capacity ACB control panel board with APFC made out of CR sheet having Size-Height-2000MM X Breadth-4250MM X Depth-1000, Floor mounting with primer coated with Powder coated paint and provided with required gasket for dust / vermin proof with degree of protection IP42 suitable for 415V ,3 phase, 50Hz, 4 wire system fabricated up to 2MM thick (1.6 mm for doors) with panel accessories.{Panel weight consider from analysis}, 800A,4Pole,50kA/EDO, Microprocessor Based Air Circuit Breaker For Main Incomer(Make-SIEMENS/ L&T/ SCHNEIDER/ABB/BCH/C&S), 25A, Breaker control switches (Trip-Neutral-Close).(Make-L&T/ SIEMENS/ ABB/ BCH/ C&S/ SCHNEIDER/ ANCHOR), 25A,Local-Remote, Auto-Manual Switches.(Make-L&T/ SIEMENS/ ABB/ BCH/ C&S/ SCHNEIDER/ ANCHOR), Indicator (Red/Yellow/Green).(Make-L&T/C&S/ABB/BCH), Indicator(Blue).(Make-L&T/C&S/ABB/BCH), Three phase Digital Ammeter Accuracy class-1.0. (96 x 96 MM/MAKE--SECUR/ C&S/ TECHNO) (l.S), Three phase Digital Volt meter Accuracy class-1.0. (96 x 46 MM/MAKE--SECURE/ C&S/ TECHNO) (L.S), 10A/AC3 Auxiliary Contactor/ 230V .(Make-L&T/ BCH/ TC/ABB/ C&S /SIEMENS /SCHNEIDER /ANCHOR)-, 6A /4Pole M.C.B.for meter wiring. (Make-L&T/BCH /TC /ABB/C&S), 6A /2Pole M.C.B.for fan & relay wiring. (Make-L&T/BCH/TC/ABB/C&S), Copper Bus-Bar(50MM X10MM)/ (50MM X8MM).Weight consider from analysis, 800/5A VA-15,CL-1,ID-85MM C.T.(Make-KAPPA/AE/ELMEX) (L.S), 50-63A/4Pole M.C.C.B,36kA{For light load- & ancillary load-}.(Make-L&T/ SIEMENS/ ABB/ BCH/ C&S/SCHNEIDER)-As per requirement, 1.5MM² single core copper cable. (Make-POLYCAB/ HAVELLS /FINOLEX/KEI)(L.S), 10MM² single core copper cable. (Make-POLYCAB/ HAVELLS /FINOLEX/KEI)(L.S), 1.5MM² Cable Socket (Cop). (Make-KAYCEE/PTR/ DOWELLS) (L.S), 10MM² Cable Socket (Cop). (Make-KAYCEE/PTR/ DOWELLS) (L.S), 25 X 25 MM PVC Cable Ducts.(Make-L&T/SALZER/ KAYCEE), 25 MM PVC Cable Ducts Cover.(Make-L&T/ SALZER /KAYCEE), 150MM cable Tie.(Make-HOODS/ ELETTRO) (L.S.), 200MM cable Tie.(Make-HOODS/ ELETTRO) (L.S.), PVC Tape(Make-STEELGRIP/ ANCHOR/CONA) (L.S.), MCB fixing Iron Channel / DIN 15/5.5MM - 1M ( suitable for M4 Terminal).(Make-WAGO/SALZER), Finger Type Insulator/one Bus -Bar Support For Capacitor Bank.(Make-RAMANUJ/WAGO), Bakelite sheet(Thick-4MM, Required size - 10" X 28" = , 10" X 18" , 10" X 8" , 28" X 28" ,35" X 28" ), 12MM PVC Spiral (L.S.), 25MM X 25MM PVC Mount (L.S.), 2.5MM² Ferrules.(L.S.), 93MM Colour Insulated Heat Shrinkable Sleeves.(Make- RAMANUJ) (L.S), Galvanized coated nut-bolt,Plain washer, Spring washer (L.S.)-As per requirement

1

524101

524101.27

... More
VFD Panel Supply,Fitting & fixing of 160KW VFD, following specification:- Ambient temperature - -10 to + 50°C; up to + 60°C with derating at 2% per degree rise in temperature. Protection design - IP20 standard, NEMA Type 1-Kit ( optional), IP55/NEMA Type 12 external heatsink ( factory option). Mounting - Horizontal ( 0.75 KW to 75 kW (HD). Overload capacity - 150 % 1 min. (HD, heavy duty) or 110% / 1min. (ND, normal duty. Rated voltage - 200 to 240 VAC, -15 to +10 % 50 / 60 Hz +/-5 %. Output frequency - 0 to 590 Hz. Carrier frequency - 400V Class; 2-15 kHz up to 55KW (ND) ; 2-10 kHz from 75 kW (HD); 2 kHz from 250 kW to 355 kW (ND).Control inputs - 8 digital (sink / source), 3 analog (current/voltage), 1 pulse (HTL, max. 32 kHz), Control output - 4 relay 2 analog ( current/voltage), 1 pulse (HTL, max. 32kHz), 24 Vdc for external sensors available (max. 150 mA) Motor types - Induction Motor ( IM), permanent Magnet Motor (IPM/SPM), Synchronous Reluctance Motor(S (SynRM).Protective functions - Stall prevention, overload prevention,overtemperature prevention - and further protective functions for the motor,the application and the inverter drive. Self-monitoring - Monitoring of main components ( fans, IGBTs, capacitors, charging circuit) with alarm when reaching a certain lifetime.(Make-SIEMENS/ L&T/ SCHNEIDER /ABB/ YASKAWA)-, 320-400A/3Pole M.C.C.B,36kA (Make-L&T/ ABB/ SIEMENS / BCH/ C&S/ SCHNEIDER)-, 400A/3P/1set of 6 Spreader Terminals. (Make-L&T/ C&S/ BCH/ TC/ ABB/SCHNEIDER/SIEMENS), Three phase Digital Ammeter Accuracy class-1.0. (96 x 48 MM/MAKE--SECUR/C&S/TECHNO), Three phase Digital Volt meter Accuracy class-1.0. (96 x 48 MM/ MAKE--SECURE/ C&S/ TECHNO), Indicator(Red/Yellow/Green).(Make-L&T/C&S/ABB/BCH/TC), Indicator(Blue).(Make-L&T/C&S/ABB/BCH/TC), 10"Cooling fan(MAKE-HIGH COOL / SALZER/ KAYCEE), 6A /4Pole M.C.B.for meter wiring. (Make-L&T/BCH/TC/ABB/C&S), 6A /2Pole M.C.B.for control wiring (Make-L&T/BCH/TC/ABB/C&S), 10A/AC3 Auxiliary Contactor/ 230V .(Make-L&T/ BCH/ TC/ABB/ C&S / SIEMENS/SCHNEIDER/ANCHOR), 400A, Din Type HRC Fuse Links. (Make-L&T/ SIEMENS/ ABB/ BCH/ C&S/ SCHNEIDER), 200-800A, Din Type HRC Fuse Base.(Make-L&T/ SIEMENS/ ABB/BCH/ C&S/SCHNEIDER)1kva(as per VFD control voltage required) Control transformer, Copper Bus-Bar(40MM X6MM) weight consider from analysis, 400/5A VA-15,CL-1,ID-55MM C.T.(Make-KAPPA/AE /ELMEX) , Push-Button with Indicator(Make-L&T/BCH/TC/ABB/C&S), Contact Element-NO/NC.(Make-L&T/BCH/TC/ABB/C&S), 1.5MM² single core copper cable. (Make-POLYCAB/ HAVELLS /FINOLEX/KEI)(L.S), 1.5MM² Cable Socket (Cop). (Make-KAYCEE/PTR/DOWELLS) (L.S), Single Pole Bus-Bar Support (Make-RAMANUJ/WAGO), 25 X 25 MM PVC Cable Ducts.(Make-L&T/SALZER/ KAYCEE), 25 MM PVC Cable Ducts Cover.(Make-L&T/ SALZER /KAYCEE), 150MM cable Tie.(Make-HOODS/ ELETTRO) (L.S.), 200MM cable Tie.(Make-HOODS/ ELETTRO) (L.S.), PVC Tape(Make-STEELGRIP/ ANCHOR/CONA) (L.S.), MCB fixing Iron Channel / DIN 15/5.5MM - 1M ( suitable for M4 Terminal).(Make-WAGO/SALZER), 12MM PVC Spiral (L.S.), 25MM X 25MM PVC Mount (L.S.), 2.5MM² Ferrules.(L.S.), 73MM Colour Insulated Heat Shrinkable Sleeves.(Make- RAMANUJ), Galvanized coated nut-bolt,Plain washer,Spring washer (L.S.).

4

751874

3007497.8

... More
APFC Supply,Fitting & fixing of 500-630A/3Pole M.C.C.B,36kA (Make-L&T/ ABB/ SIEMENS/BCH/C&S/ SCHNEIDER), 630A/3P/1set of 6 Spreader Terminals. (Make-L&T/ C&S/ BCH/ TC/ABB/SCHNEIDER/SIEMENS), 6A /4Pole M.C.B.for meter wiring. (Make-L&T/BCH/TC/ABB/C&S), 6A /2Pole M.C.B.for fan & relay wiring. (Make-L&T/BCH/TC/ABB/C&S), 10A /3Pole M.C.B.for 5KVAR capacitor(Make-L&T/ ANCHOR /C&S/ABB/BCH/SIEMENS), 63A /3Pole M.C.B.for 30KVAR capacitor(Make-L&T/ MARU/ C&S /ABB/ BCH /ANCHOR/LEGRAND), 1.5MM² single core copper cable. (Make-POLYCAB/ HAVELLS /FINOLEX/KEI) (L.S),2.5MM² single core copper cable {For 5KVAR Capacitor} (Make-POLYCAB/ HAVELLS /FINOLEX/ KEI) (L.S.), 16MM² single core copper cable {For 30KVAR Capacitor} (Make- POLYCAB/HAVELLS /FINOLEX/ KEI) (L.S.), Indicator(Red/Yellow/Green).(Make-L&T/C&S/ABB/ BCH), Indicator(Blue).(Make-L&T/C&S/ABB/BCH), Three phase Digital Ammeter Accuracy class-1.0. (96 x 48 MM/MAKE--SECURE) (L.S), Three phase Digital Volt meter Accuracy class-1.0. (96 x 48 MM/MAKE--SECURE) (L.S), 1.5MM² Cable Socket (Cop). (Make-KAYCEE/PTR/DOWELLS) (L.S),2.5MM² Cable Socket (Cop). (Make-KAYCEE/PTR/DOWELLS) (L.S), 16MM² Cable Socket(Cop).(Make-KAYCEE/PTR/DOWELLS) (L.S.), 600/5A VA-15,CL-1,ID-70MM C.T.(Make-KAPPA/AE/ELMEX), 12 Steps APFC Relay,230V (Make-EPCOS/L&T/C&S), 2kva/0-280V Control transformer, 7KVAR Capacitor duty contactor.(Make-EPCOS/L&T/ C&S), 33KVAR Capacitor duty contactor(Make-EPCOS/ L&T/ C&S), 5KVAR Capacitor,440V(Make-EPCOS/C&S/L&T), 30KVAR Capacitor,440V(Make-EPCOS/L&T/C&S) and 4"Cooling fan(MAKE-HIGH COOL / SALZER/ KAYCEE), Copper Bus-Bar(50MM X8MM /40MM X10MM). (Weight consider from analysis), Single Pole Bus-Bar Support(Make-RAMANUJ/WAGO)(L.S), Base 2pole connector(Make-RAMANUJ/WAGO) (L.S), MCB fixing Iron Channel / DIN 15/5.5MM - 1M ( suitable for M4 Terminal).(Make-WAGO/SALZER)-1No, 25 X 25 MM PVC Cable Ducts.(Make-L&T/ SALZER / KAYCEE), 45 X 30 MM PVC Cable Ducts.(Make-L&T/SALZER /KAYCEE), 25 MM PVC Cable Ducts Cover.(Make-L&T/ SALZER /KAYCEE),45 MM PVC Cable Ducts Cover.(Make-L&T/ SALZER/ KAYCEE), 150MM cable Tie.(Make-HOODS/ELLETRO).(L.S.), 200MM cable Tie.(Make-HOODS/ ELLETRO) (L.S.), PVC Tape(Make-STEELGRIP/ ANCHOR/CONA).(L.S.), 12MM PVC Spiral.(L.S.), 25MM X 25MM PVC Mount.(L.S.), 2.5MM² Ferrules. (L.S.), 81MM Colour Insulated Heat Shrinkable Sleeves.(Make- RAMANUJ), 93MM Colour Insulated Heat Shrinkable Sleeves.(Make- RAMANUJ), Galvanized coated nut-bolt,Plain washer,Spring washer.(L.S.)-Each quantity as per required

1

186210

186210.29

... More
Installation and commissioning of panel.:- L.T 240MM²,3½Core/ X 2R,Armoured,Aluminium Cable.(Make-HAVELLS/POLYCAB /FINOLEX/KEI) {For transformer to panel DG to panel)

500

2404

1202250

... More
L.T 10MM²,4Core/ ,Armoured, Aluminium Cable.(Make-HAVELLS/ POLYCAB /FINOLEX/KEI) {For transformer to panel DG to panel)

100

281

28140

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/ METAL pipe as required. Above 185MM² and upto 400MM²

500

134

67000

... More
Upto 35MM² (For 4core/10MM²-100Mtr + 16core / 2.5MM²-800Mtr)

900

37

33300

... More
120MM² single core/ X 6R flexible copper cable.(Make-HAVELLS/ POLYCAB/ FINOLEX/KEI)

150

2100

315000

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Above 35MM² and upto 95MM²(cop)

400

92

36800

... More
120MM² Cable Socket(Cop). (Make-KAYCEE/PTR/DOWELLS)(L.S.)

60

97

5866.8

... More
Supplying and installing following size of perforated painted with powder coating M.S cable trays with perforation not more than 17.5%, in convenient section, joined with connectors, suspended from the celling with M.S suspenders including bolts & nuts, painting suspenders etc as required. 200 mm width X 50 mm depth X 1.6 mm thickness

30

689

20670

... More
300 mm width X 50 mm depth X 1.6 mm thickness.

50

777

38850

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 240MM² (62mm) {Alu}

8

1027

8216

... More
3 X 120MM² (45mm) {cop}

16

597

9552

... More
Supply,installation testing and commissioning of remort push-botton system in all complete. L.T. 2R, 16C X 2.5MM² X LPE-Cu armoured cables single stand.

800

1195

956400

... More
Supply, installation and testing of Maintenance free safe Earthing Electrodes with ISI G.I pipe dia 75mm as Secondary electrode with wall thickness of 2.6 mm and the Primary Earthing Electrode will be 50mm X 6mm X 1no M.S hot dipped galavanized strip filled with a highly conductive & non-corrosive compound in between the Primary Earthing and the secondary Earthing, the surface Area in will be 7,06,500sqmm for 3mtrs length and cross sectional primary conducting area is 300 sq.mm An Solid G.I Base plat seals the unit at the bottom and providing of masonry enclosure with cover plate.as per direction of Engg.-in-charg (MES- GFC ground Filling compound will be provided in 25 kgs Bags.) (MES-GFC ground Filling compound will be provided in 25 kgs Bags.) (2 bags required for each earthing electrode.) 2nos earthing connection all motors and 2nos earthing connect in all panel.

4

12061

48247.2

... More
Providing and fixing 25 mm X 5 Mm G.I . Strip on surface or in recess for connections etc. as required.

75

244

18300

... More
Desiging, supplying, installing, commissioning & testing of CCTV IR water proof camera suitable for upto 100ft. with control key board, DVR, Hard Disk,cables, UPT transreceivers etc. complete with not less than following specifications 1. Four numbers of IP Camera with night vision functionality with range up to 30 meters. Camera construction shall be suitable for weather proof outdoor installation. 2. Eight Channe DVR withmetal body consturction, having software features of motion detect recording. 3. 3.5 inch 2 GB HDD 4. 8 port POE Switch 5. 32 inch LED Screen, Keyboard & mouse .Make- Hikvision, CP Plus, Evision, Honeywell all complete as per specification

2

56336

112672

... More
First Aid box shok treatment chat (odia/hindi/english)8 mm thick rubber mat,danger board(200 mmx1500 mm)

1

6015

6015

... More
(5 year )five year operation and maintenance)(Including contribution towards EPF, ESI, Labour cess, Contractors Profit & OH Charges but excluding cost of chemicals & Energy charges) Supply of manpower consisting of 1 Number of electrician/High skilled manpower, 2 No pump driver and 1 number helper daily including materials require for repair and maintenance of Pump set,VFD Panel, APFC Panel, pipe lines , Sluice valves,air valves,NR Valves, MS pipe laid under this project including painting, repair and replacement of damaged items, spares etcfor the item of the works executed under this project .as per specification and direction of the Engineer-in-charge.

1

6898453

6898453.45



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.