Get tender documents at just ₹299 per tenderKnow More
Search made simple for latest tendersNo hidden charges. No keyword restrictionsExplore Our Plansor Pay Per Tender

Paradip Port Trust Tender

View complete overview of Orissa Paradip Port Trust Tender

Summary

Solar Water Heating System

Description

Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

  • Tender Id

    Unregistered TenderId
  • Tender No

    Data for unregistered User Data for unregistered User Data for unregistered User Data for unregistered User
  • Tender Authority

    Data for unregistered User Data for unregistered User Data for unregistered User Data for unregistered User
  • Purchaser Address

    Authority for unregistered User
  • Email

    Data for unregistered User
  • Website

    wwww.unregistereduser.com
http://bit.ly/2y8uxEJ

Bid Number: GEM/2019/B/340153 Dated: 03-09-2019 Bid Document Bid Details Bid End Date/Time 16-09-2019 14:00:00 Bid Life Cycle (From Publish Date) 90 (Days) Bid Offer Validity (From End Date) 30 (Days) Ministry/State Name Ministry Of Shipping Department Name Na Organisation Name N/a Office Name Materials Management Division Total Quantity 1 Item Category solar water heating system MSE Exemption For Years Of Experience And Turnover No Startup Exemption For Years Of Experience And Turnover No Bid to RA enabled No Solar Water Heating System ( 1 pieces ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) GENERIC Conformity to standards for Solar water Heating System -Code for Acceptance IS:12976:1990 with latest amendment * BIS Approved Yes Yes If Yes , Mention CM/L No. otherwise write NA - * Model Number of Solar Water Heater System - * Solar water Heating System Compatibility with Solar water Heating System with out Heat Exchanger Solar water Heating System with out Heat Exchanger 1 / 6 Heat Exchange Region Type 2 Warm (Areas where ambient temp. is moderate and do not normally below 5 Deg. C * Rated Capacity in Litres per Day (LPD) 500 500 Warranty (Years) 3 Years 3 Years CONSTRUCTIONAL Aperture area of collector , Sq. Meteres (Sq Meter) 9.0 9.0 Electrical Heater ( Back up ) Capacity (kw) 2 2 Capacity of Make up tank( SWHS with Heat Exchanger only ) (Ltrs) NA NA Solar Flat Plate shall be BIS marked and as per IS :12933/2003 with amendment 1 to 3 Yes * Type of Cover Plate conforming to IS 12933/2003 Made up of Toughened Glass with thickness 4.00 mm minimum Made up of Toughened Glass with thickness 4.00 mm minimum Solar Transmittance for cover plate at normal Incidence (%) 92 * Material for Collector Box Aluminium Aluminium Numbers of collectors - * Minimum Channel Section Thickness for sides ( For Al based) > / = 1.4 mm for aluminium based * Minimum Thickness of Sheet for Bottom ( For Al based) > / = 0.45 mm for aluminium based * Minimum Thickness of Sheet used as Support for Glass retaining ( For Al based) > / = 1.2 mm for aluminium based * Thickness of Sheet for entire body > / = 1.0 mm for aluminium based * CRCA Material Thickness 0 for Aluminium material * Riser and Header assembly designed for Riser and Header assembly designed for * 2 / 6 working pressure working pressure 24.5 k pa tested for leakage at a minimum hydraulic pressure of 490 K pa Number of absorber sheets per collector - * Numbers of Header Tubes - * Numbers of Riser Tubes - * Diameter of Header Tube (mm) > / = 24.5 mm * Diameter of riser tube (in mm) >/= 11.5 mm * Thickness of Header Tube (mm) >/=0.71 * Thickness of Riser Tube (mm) > / = 0.56 mm * Material of Riser /Header for Absorber Copper Only * Distanace Between Risers from center to center (mm) > / = 120 (mm) * Material of sheet for absorber Copper Copper Collector Box Insulation Back and sides * Thermal Resistance of Insulation in Square Degree for Back Face >/=0.96 W/Km * Thermal Resistance of Insulation in Square Degree for Side Face >/=0.47 W/Km * Gasket and Grommets shall confirm to IS 12933/2003 with latest amdt Yes * Material for Hot water storage Tank Mild Steel Mild Steel Name the Material if choose others - * Non Pressure Type Hot water Storage Tank Yes * Position of Hot water tank Horizontal * Thickness of sheet of Hot water tank (mm) - * Hot water Tank Insulation Density ( >/=40 * 3 / 6 High density PUF insulation for 32 kg/ meter cube or higher density (mm) Hot water Welding MIG * Coating Material for Hot water tank Polyster Epoxy Plus Balck Epoxy based Paint * Thickness of Coating (micron) - * Tank stand Material Mild Steel * Size of Tank Stand (L x W x H ) Must be Greater Than 38 x 38 x 4 (mm3) Yes * Type of Heat Exchanger cage Type * Material for Heat Exchanger Copper Copper Thickness of tube of

Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.