Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.
Costs
EMD
₹ 28,950Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Enhancement Of Wall Thickness Of Building No 0423 Of Unit-04 Inside Factory Area Of Ofbl
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_MIL_170952_1Bid Award Id
ViewTender No
3012/Genl/TE-14/EO(C)/2023-24Tender Authority
Ordnance Factory Board ViewPurchaser Address
-Website
http://etenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
ENHANCEMENT OF WALL THICKNESS OF BUILDING NO-0423 OF UNIT-04 INSIDE FACTORY AREA OF OFBL
Remedial measure of safety during execution of work
Bidders compliance TE-14-2023-24
Important Note on Civil-Electrical work
Format for EMD Bank Guarantee (BG)
BOQ Items
Taking down chowkhats or frames (without taking off shutters from the frame) exc. 1.5 sqm but not exc.4 sqm each and refixing in other places as per direction of E-I-C
4
-
-
Taking down chowkhats or frames (without taking off shutters from the frame) not exc. 1.5 sqm each and removing to store as per direction of E-I-C
5
-
-
Taking down cement or cement lime plaster any description on brick or stone wall, etc. including racking out joints, hacking for keys, scrubbing down with water , etc as per direction of E-I-C.
280
-
-
Excavating in trenches, n exc1.5m wide and n exc. 1.5 m in depth for foundation and getting out in hard/dense soil as per the direction of Engineering-in-charge.
32
-
-
Removing excavated material ( Soil) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point as per the direction of Engineering-in-charge.
32
-
-
M&L for Sand filling under floors or in foundations including watering and consolidation as per the direction of Engineer-In-Charge.
6
-
-
M & L for cement concrete Type C2 (1:3:6 ) 40mm graded aggregate cement concrete in foundation filling and mass concrete as per the direction of Engineer-In-Charge. .
15
-
-
M&L for Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1: 4. ( with modular bricks) includung curing etc as per direction of EIC .
90
-
-
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clipsas per the direction of Engineering-in-charge .
1860
-
-
M&L for formwork to flat sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter as per the direction of Engineering-in-charge.
200
-
-
M & L for reinforced cement concrete (nominal mix) type B11:2:4 (20mm graded aggregate) in walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilaster and buttresses as per the direction of Engineering-in-charge.
13
-
-
M & L for rendering 12mm thick plaster on fair faces of brick work or concrete surfaces in cement plaster ( 1:4) as per the direction of Engineering-in-charge.
450
-
-
M&L for cement concrete type-I M15 (1:2:4)mix using 20 mm graded aggregates as per the direction of Engineering-in-charge.
11
-
-
Preparing surfaces plastered or unplastered new surfaces on walls and applying two coats of cement paint as per direction of Engineering-in-charge
350
-
-
Preparing surfaces plastered or unplastered surfaces of any description wood,steel,iron.concrete, brick,stone, etc., exceeding 10cmin grith applying two coat of fire resistance paint, as per direction of Engineering-in-charge
100
-
-
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories).
80
-
-
Cast iron rainwater socketed pipes( Fixing only any size) of 100mm dia with cement joints, without ears .
80
-
-
Taking down carefully copper/aluminium light point wiring in complete (fittings such as switches, ceiling roses, pendants, regulators, sockets etc. to be measured separately), removing materials to store and making good disturbed surfaces of walls if any.
9
-
-
Supply and fixing LED light fitting 1x 30 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. Complete with all accessories including flame proof gland for in & out of power supply,prewired and including connecting up with three core flexible copper conductor cable with suitable size.
2
-
-
M & L for one light point wiring with copper conductor cables of FRLS grade & 1.5 sq. mm size in stove enamelled steel conduit.
8
-
-
M & L point wiring, independent, for one 3 pin socket outlet, 15 Amps, , wiring with copper conductor cables of FRLS grade & 4 sq. mm size in stove enamelled steel conduit.
3
-
-
Supply & fixing of switch flame proof rotary type with termination box in LM6, 6/16A, single pole 250V with flame proof gland for in & out of power supply.
3
-
-
Supply & fixing of flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A,250V, 2P+earth with flame proof gland for in & out of power supply.
3
-
-
Fixing in repair existing test terminal block of building lightning protection system.
4
-
-
Fixing in repair existing aluminium strip 25 x 3.15 mm with saddles and fixing screws for down conductors above ground.
20
-
-
Providing & fixing 25 mm x 5 mm GI strip on surface or in recess for connections etc. as required.
44
-
-
Supplying & fixing of 25 mm dia of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
48
-
-
Removal of GI Earth strip/ Aluminium Strip of any size in complete from the existing wall for carrying out necessary modification work.
64
-
-
Removal of Test Terminal Block of Building Lightning Protection System complete from the existing wall for carrying out necessary modification work.
4
-
-
Supply & Fixing of 3/4 Way Flameproof Junction box along with flame gland and complete accessories.